1. New Corporate Headquarters opened in October 2006 The Company Founded in 1984 Park House Healthcare Ltd is recognised as one of the leading manufacturers of specialist pressure relieving and pressure reducing equipment in the U K Park House Healthcare Ltd has an extensive product portfolio and the facility to customise products to suit customer needs whilst offering solutions in pressure care postural management and moving and handling Employing over 100 full time staff at our 60 000 sq ft state of the art Corporate Headquarters in West Yorkshire Park House Healthcare are proud to offer in house manufacturing a full product audit and decontamination service and a network of distribution centres as part of our continued commitment to Customer Care 24 hour care 365 days a year dedicated internal personnel manage specific regions and divisions ensuring one on one personal customer service at all times With distributors in over 25 countries Park House Healthcare are a truly international company and we place important emphasis on providing high levels of customer care to ensure we exceed customer expectations at all times Additional support nationwide is available through our service centres situation strategically around the country Park House Healthcare Ltd is a respected member of the British Healthcare Trade Association and has BS EN ISO 9001 and EN 46002 accreditation which is the specific qua
2. Park House Healthcare DELTA PLUS PA8900 Bariatric Mattress Replacement System User Manual CONTENTS Introduction 1 1 General Information 1 2 Intended Use Product Description Installation 3 1 Setting Up Operation 4 1 Function Description 4 2 Operating Instructions 4 3 CPR 4 4 Low Pressure and Alarm Functions Cleaning 5 1 Pump Unit 5 2 Mattress Storage Maintenance 7 1 General 7 2 Air Filter Replacement 7 3 Fuse Replacement Troubleshooting Technical Description Guarantees and Warranty 10 1 Pump Unit 10 2 Mattress 10 3 Guarantee 10 4 Warranty 10 5 Claims relating to Guarantee and Warranty 10 11 12 13 14 IMPORTANT SAFEGUARDS READ ALL INSTRUCTIONS BEFORE USING DANGER To reduce risk of electrocution Always unplug this product immediately after using Do not use while bathing Do not place or store product where it can fall or be pulled into a tub or sink Do not place in or drop into water or other liquid Do not reach for a product that has fallen into water Unplug immediately ON ONS WARNING To reduce risk of burns electrocution fire or injury to persons This product should never be left unattended when plugged in Close supervision is necessary when this product is used on or near children Use this product only for its intended use as described in this manual Do not use attachments not recommended by the manufacturer 4 Never operate this product if
3. To turn on the control unit ALARM MUTE Enable and disable the audible alarm Press this button to mute the audible alarm The alarm will sound again after 3 minutes if the problem has not been resolved PANEL LOCK Locks the control panel to prevent unauthorised setting changes To unlock the panel press and hold it for 3 seconds LOW PRESSURE INDICATOR ule No light normal condition mattress is operating accordingly 2 Yellow light pressure has not yet reached the preset setting 3 Flashing yellow light low pressure condition see Troubleshooting Delta Plus User Manual Control Button Function Description AUTOFIRM For maximum inflation of the mattress All other functions will be disabled unless this button is pressed again This mode will operate for 20 minutes and then return to default settings automatically STATIC Non alternating mode to facilitate nursing procedures To resume alternating mode simply press this button again SEMI RECUMBENT SETTING This will increase the internal cell pressure by 10 to accomodate the semi recumbent position CYCLE TIME Four alternating cycle times Use UP DOWN function to adjust the cycle time through 10 15 20 and 25 minute cycles COMFORT RANGE Six comfort levels for the patient Use UP DOWN function to adjust the comfort levels 1 being the softest and 6 being the firmest 4 2 Operating Instructions 1 Press the POWER button on the display pan
4. 1 Mattress 2 Pump Unit 3 Air Tube Connector 4 Control Panel Delta Plus User Manual 3 Installation 3 1 Setting Up 1 Place the mattress on top of the bed frame Making sure the hoses are at the foot end of the bed The mattress can be secured firmly by fixing the straps at the bottom bed frame NOTE Please cover the mattress with a cotton sheet to avoid direct skin contact and for patients comfort oP i 2 Hang the pump at the foot end of the bed adjust the hangers to secure the pump against the foot board 3 Connect the air tube connector from air mattress to the JA pump unit When a click is felt heard the connector is secure AN NOTE Check and ensure the air tubes are not kinked or tucked under mattress 4 Plug into mains electrical outlet A NOTE Make sure the pump unit is suitable for sN the local power voltage 5 Then turn the main power switch ON The power switch is located on the right side panel of the pump unit A NOTE Ensure the CPR connectors are sealed completely WN Delta Plus User Manual Installation tips are listed betlow After installation any extra wire of the power cord should be neatly arranged to avoid any stumbling The equipment should be placed in a position where users have complete access 4 Operation A NOTE Always read the operating instructions before use 4 1 Function Description Control Button Function Description POWER
5. it has a damaged cord or plug if it is not working properly if it has been dropped or damaged or dropping in water return the product to a service centre for examination and repair oOn gt 5 Keep the cord away from heated surfaces 6 Never block the air opening of this product or place it on a soft surface such as a bed or couch where their openings may be blocked Keep the air opening free of lint hair and other similar particles T Never drop or insert any object into any opening or hose 8 Connect this product to a properly grounded outlet only See grounding instructions NOTE CAUTION AND WARNING STATEMENTS NOTE Indicates some tips CAUTION Indicates correct operating or maintenance procedures in order to prevent damage to or destruction of the equipment or other property WARNING Calls attention to a potential danger that requires correct procedures or practices in order to prevent personal injury SYMBOLS a BF symbol indicates this product is according to the degree or protecting against electric shock for type BF equipment AN Attention should read the instructions IPXO Enclosed equipment is without protection against ingress of water Disposal of Electrical amp Electronic Equipment WEEE This product should be handed over to an applicable collection point for the recycling of electrical and electronic equipment For more detailed information about recycling of this product please con
6. cement Disconnect the plug from the mains power 2 The filter is resuable and can be washed gently with a mild detergent and water 3 We suggest replacing the air filter regularly if the environment is dirty this will help to improve the airflow Spare filters are available from Park House Healthcare Delta Plus User Manual 8 Troubleshooting Check if the plug is connected to the mains Check if there are any blown fuses Power is not ON Check that the connection between the air tube connector and the pump unit is tightly secured A Check that all tubing connections along the mattress Alarm is on dible and visual betaine au Check if the CPR is engaged Check if there are any leaks from the air cells Check that the correct comfort setting has been set Pressure setting may be inadequate for the patient Patient is bottoming out adjust comfort range 1 to 2 levels higher and wait for a few minutes Press handles on both sides of air tube connector Air tube connector can t fit slightly before pushing the connector into the pump unit into the pump unit Make sure the connector is tightly secured a click should be heard felt when the connector is secure No air is being produced from some of the air outlets of the tube connectors This is normal in alternating mode Air outlets take turns to produce air during their preset cycle time If your problem cannot be resolved usi
7. el to start the system 2 For faster inflation the AUTOFIRM function can be activated This mode will last for 20 minutes and then it will return to default settings automatically 3 Once the mattress is fully inflated the pump settings can be changed to accomodate patient comfort or if recommended by a physician WE Delta Plus User Manual In the event of an emergency to perform CPR on the patient quickly pull the CPR tag to release air from the mattress The CPR tags are located at the head end on the right hand side of the mattress 4 4 Low Pressure and Alarm Functions If an abnormal low pressure is detected the Low Pressure Indicator flashing yellow LED will illuminate and the alarm will sound Check if all the connections are correctly installed and secure as per installation instructions in this manual A NOTE H If the pressure level is constantly low check for any leakage in the air cells or connecting tubes If necessary replace any damaged cells or tubes If you require replacements please contact Park House Healthcare To silence the alarm simply press the alarm mute button The alarm will be silent for 3 minutes but the Low Pressure Indicator will remain flashing After 3 minutes the alarm will sound again if the pressure has not returned to normal 5 Cleaning The following guidelines are suggested by Park House Healthcare Ltd as being suitable infection control procedures Further information is availab
8. le upon request 5 1 Pump Unit It is important to follow the cleaning procedures for single patient use General cleaning may be affected by using a cloth dampened with a mild detergent and water solution This approach may be followed either by wiping with a sodium hypochlorite solution to a dilution of 1000 ppm or by using an alcoholic wipe Wipe the pump unit with a damp cloth and a mild detergent and keep it away from dust If another detergent is used choose one that will have no chemical effects on the surface of the plastic case of the pump unit Delta Plus User Manual D A CAUTION p Do not immerse or soak pump unit Do not use hyper carbonate or phenol based cleaning solutions Do not use any abrasive compounds or cleaning pads 5 2 Mattress During general use the mattress and tube set may be cleaned by using a mild detergent solution Where appropriate mattress covers may be completely removed for laundering or sterilisation Whenever there is staining or body fluids on the mattress including the cells and tubing then a sodium hypochlorite solution to a dilution of 1000 ppm should be used following thorough cleansing with soap and water All mattress covers may be laundered as follows Pre Wash 80 C 15 minutes Main Wash 80 C 15 minutes Followed by cold rinses and extraction A CAUTION Do not use phenolic based products for cleaning A CAUTION gt Dry the mattress on a SUNLESS capitalised area after clea
9. lity standard for Medical Devices All products are CE marked in accordance with the European Directive 93 42 EEC ISO 9001 Approved code Registered k j 2 Healthcare ISO Certificate No 8019 Park House Healthcare Ltd CE Certificate No CA001810 Whitehall 26 Business Park Master Indemnity Assurance No IFA 2433 0451 CCI 1 Heathfield Lane Birkenshaw West Yorkshire BD11 2HW UK 0845 0600 333 0845 0600 334 sales parkhouse he com 44 0 1274 475000 44 0 1274 475046 international parkhouse hc com www parkhouse he com UM PA8900 120CT2010 REV1 Due to its policy of continued development and improvement Park House Healthcare Ltd reserves the right to amend any details and specifications without notice Copyright Park House Healthcare Ltd 2010 10
10. lowing the date of dispatch 10 3 Guarantee Park House Healthcare guarantees to repair or place any equipment issued to its customers which is found to be faulty during the relevant guarantee or warranty period The Company s guarantees are subject to following conditions a That the equipment has been used for the purpose for which it was intended b That the usage has been on a fair wear and tear basis c That the Company s cleaning disinfection guidelines have been followed d That the Company s maintenance guidelines have been followed e That maintenance has been carried out by a suitable and qualified person 10 4 Warranty Extended warranties can be purchased from Park House Healthcare for more information contact Customer Services on 0845 0600 333 10 5 Claims relating to Guarantee and Warranty In the event of a fault being discovered within the warranty period the customer must notify Park House Healthcareat the earliest opportunity If upon inspection Park House Healthcare accepts liability then the equipment shall be repaired or replaced immediately If Park House Healthcare does not accept liability it shall inform the customer of its reasons for declination and provide the customer with an estimate on either the repair or replacement cost Park House Healthcare reserves the right to alter or amend this document without prior notice Delta Plus User Manual Notes
11. ng the above information please contact Park House Healthcare Delta Plus User Manual 9 Technical Description Product Code PA8900 Specification AC 220 240V 50 60Hz 1 0A Power Supply refer to rating label on the product for 230V system Fuse Rating TIA Dimension L x W x H 37 x 27 x 13 cm Weight 6 kg Environment Temperature Operation 10 C to 40 C 50 F to 104 F Storage 15 C to 50 C 5 F to 122 F Shipping 15 C to 70 C 5 F to 158 F Humidity Operation 10 to 90 non condensing Storage 10 to 90 non condensing Shipping 10 to 90 non condensing Atmosphere 700 hPa to 1060 hPa Classification Class Il Type BF IPX0O Applied Parts Mattress Not suitable for use in the presence of a flammable anaesthetic mixture No AP or APG protection Continuous operation Mattress Specification Dimension L x W x H Weight 196 x 107 x 20 cm 11 6 kg 318 kg or 50 stones both sides Maximum Patient Weight Contact the distributor or EU representative for further technical documents A NOTE H The specification is also suitable for other areas operating with the same power supply Delta Plus User Manual 10 Guarantees and Warranty 10 1 Pump Unit All new pumps have a guarantee for a period of 2 years following the date of dispatch 10 2 Mattress All new mattresses have a guarantee for a period of 2 years fol
12. ning JN CAUTION During cleaning procedures suitable protective clothing should be worn Ensure that the mains power supply to the pump has been disconnected prior to cleaning A CAUTION Follow the national requirements for the correct disposal of the pump unit 6 Storage Pull the CPR tags and make sure all cells are deflated Lay the mattress out flat and upside down Protect the air tube coupler by putting it in the inner side of the mattress Roll the mattress from the head end towards the foot end Foot end straps can then by stretched around the rolled mattress to prevent IAUN unrolling Delta Plus User Manual 7 Maintenance 7 1 7 2 General Check the main power cord and plug for any abrasions or excessive wear Check the mattress cover for signs of wear or damage Ensure the mattress cover and tubes are connected correctly Check the air tube connections for any damage Report any problems or malfunctions to Park House Healthcare immediately Air Filter Replacement The air filter should be checked and dusted regularly once per month 1 Two foam type filters are used One is located on the bottom of the pump 2 The filter is resuable and can be washed gently with a mild detergent and water 3 We suggest replacing the air filter regularly if the environment is dirty this will help to improve the airflow Spare filters are available from Park House Healthcare Fuse Repla
13. tact your local city office household waste disposal service or the retail store where you purchased this product o Class II Equipment SAVE THIS MANUAL FOR REFERENCE 1 Introduction This manual should be used for initial setup of the system and for reference purposes 1 1 General Information The Delta Plus Bariatric System uses the most advanced technologies to deliver optimum pressure relief and comfort through whisper quiet operation The Delta Plus system has been independently tested and successfully approved to the following standards EN 60601 1 UL 60601 1 EN 60601 1 2 EN 55011 Class B IEC 801 2 IEC 801 3 IEC 801 4 IEC 801 5 EN 61000 3 2 EN 61000 3 3 1 2 Intended Use This product is an advanced alternating replacement system suitable for very high risk bariatric patients This system is intended to reduce the incidence of pressure ulcers whilst optimising patient comfort It is recommended for the prevention and treatment of pressure ulcers up to stage IV A NOTE Equipment not suitable for use in the presence of a flammable anaesthetic mixture with air oxygen or nitrous oxide Delta Plus User Manual 2 Product Description The digitally controlled pump unit provides adjustable pressure and cycle time and is compact and effective in pressure control and management The replacement mattress offers alternating therapy and provides patients with a comfortable pressure support setting