Idle Free Systems, Inc. Reference Guide
Contents
1. Be sure to connect the condenser fan harness after the front APU cover is put in place 2 59 Battery Test Procedure RF123 AGM Batteries This Page Intentionally Blank Truck Charge Circuit RF124 10 reasons that your AGM batteries are not fully charged 10 reasons that your APU AGM batteries are not fully charged Please read this before you change any APU AGM batteries If you have ever gone through the trouble of pulling all of the APU batteries tested them only to find out that they tested Good Battery needs a charge now what Check out the charge circuit of the truck BEFORE YOU PULL THE APU BATTERIES 1 Truck battery bank has a bad battery a A failed truck battery will prevent the APU batteries from being charged b A truck starter battery is subject to fail faster than an APU AGM battery because i Truck battery has the job of starting the truck ii Spends too much time at a voltage level below its minimum voltage level 11 8 VDC iii Lead plates in a starter battery are thinner than the lead plates in AGM batteries iv Lead plates in starter batteries are surrounded by liquid and AGM batteries are surrounded by poly fiber matting v The amperage leaving an APU AGM battery is a fraction of the amperage leaving the truck s starter battery bank during engine Start 2 Truck and or DC Cables are not connected to the correct connection point a Trucks that use fusible links suffer when additional batteries
2. Check input voltage OVP Reduce input voltage b Blinking slow Low input voltage Recharge battery UVP Check connections and cable The STATUS light is the c Blinking Intermittently Thermal shutdown Improve ventilation Bor Om IO Os OTP Make sure ventilation the inverter to the right of openings in inverter the GFCI 120vac outlet are not obstructed Reduce ambient temperature d Solid ON Short circuit or Winng Check AC wiring for error short circuit Overload OLP Reduce load Inverter RF105 Top Light DC input voltage light Problems and Symptoms Possible Cause Solutions No AC Power Output STATUS illuminates the red LED a Blinking fast Over input voltage Check input voltage h OVP Reduce input voltage A b Blinking slowly Low input voltage Recharge battery Yo UVP Check connections r and the cable c Blinking Intermittently Thermal shutdown Improve ventilation OTP Make sure ventilation shafts in the inverter are not obstructed Lower ambient temperature d Solid ON short circuit or Wiring Check AC wiring for error short circuit Overload OLP Reduce the load 3 1 3 Input Level Display Input Voltages LED Status DC 12V RED Slow Blink 10 3 10 6 10 6 11 0 11 0 12 1 121 142 ORANGE Blink 14 2 15 0 OVER RED Blink CTS Inverter RF105 Center Light Center Light Inverter load level Inverter load level l l l l This center light will not be lit wh
3. Circuit 8 seconds The compressor circuit will start 8 seconds after the thermostat calls for COOL During the 8 second delay the evaporator fan will come on and be up to full speed The compressor delay circuit is used to eliminate the added surge power needed to start the evaporator blower fan aioe DE 1 AMP The Thermostat sends its 12 VDC signal to the Time Delay relay prior to the A y Compressor relay E Under Bed Box UBB EL FOR TE OLA Y a SECONDS Bf kc cf 36U1 3012907 1025 SEC DOM 21 Relay Group RF106 Power Relays explanation Thermostat Wiring AGM Batteries Truck Batteries O Ti A SPERE E ES A ee F Laa gt a ae T I l A E oe An ae el ee dE Battery l a l 1 1 l 1 l 1 1 120WAC Shore pr qa k Par ae mames l gt es eo i e FUSE l 4 eT r iri Conwerter IZIWAC to IDC o INVERTER FAN BLUE YE BLACK BLACK Compressor Timer Relay YELLOW Ignition Cut Out Circuit RF107 Ignition Cut out circuit explained Ignition Cut Out Circuit Component Location Bunk Area Connected to the back side of the UBB RF110 Starts at a truck specific ignition source and nae 1 Relay is powers the UBB ignition relay Ignition Description amp Application The DC Ignition Cut out circuit is used to disable the Idle Free system when the truck s engine is running The Ignition Cut out circuit
4. Pa Me J S A E E y de i y DE Battery Separator baperan ed 7 Shore Power me Y e O rrr i This Page Intentionally Blank Inverter RF105 Inverter 12VDC to 120VAC IFS Part 35002 1500 Watt Sine Wave Component Location UBB Under Bed Module Lower level Description The Idle Free Inverter provides 120VAC sine wave power for the Air Conditioner s Compressor and Evaporator Blower Fan The Inverter is rated at 1500 watts continuous with a 3000 watt Surge Capacity The Inverter has a GFCI outlet that is used to protect against electrical shock hazards The Inverter is located in the UBB Module RF110 lower level The Inverter is installed with Stand By mode activated Stand by mode is used as an automatic ON OFF feature shuts off automatically ON with load gt 20 watts A 120VAC Power Strip is included with the Idle Free system The power strip can be used to power driver needs Some small wattage 120VAC convenience devices can be powered with the inverter if managed properly Application 120VAC Inverter Power is sent from the Inverter through two relays to activate the 120VAC Compressor circuit and the 120VAC Evaporator circuit Both Relays are controlled with a 12VDC signal from the Idle Free Thermostat RF103 The Compressor Relay sends it 120VAC to the exterior located APU The Exterior APU Module s Compressor 120VAC Circuit contains a pressure switch condenser fan relay run capacitor start
5. Delay Timer relay 37022 only affects the compressor circuit If the thermostat is in COOL amp AUTO modes the fact that the evaporator fan is running will confirm that the delay timer is in its 5 minute shut down period Confirm that the driver is shutting down the air conditioner with the ignition key instead of the thermostat Remind the system operator to always shut down the air conditioner with the thermostat Remember that the inverter will show a solid Red Light if the compressor did not start 67 8 second 5 minute Delay Circuit RF128 Description amp Application This Page Intentionally Blank Compressor A C RF129 A C Compressor Tecumseh Compressor IFS Part 434001 Component Location Truck Exterior APU Top Level Compressor Description amp Application The IFS A C Compressor operates using 120VAC power from the IFS inverter RF105 The IFS A C Compressor uses 134A Refrigerant The IFS A C Compressor has a Thermo overload switch located on the compressor top under the plastic cover Issues History Compressor was changed in early 2012 from a Panasonic to this Tecumseh Both models have the same displacement however about 100 incorrect displacement compressors were mistakenly put into service resulting in a TSB Technical Service Bulletin 1205211B that required a compressor Compressor Top Wiring change Changing to the Tecumseh Compressor required a new start Capacitor Sup R BL
6. are added to the truck because a voltage drop occurs across the fusible link This voltage drop prevents the additional batteries from being fully charged 3 DC Cables are the wrong size gauge a When alternators are upgraded because additional batteries were added to a truck the size of the DC cables Ground and positive need to be sized to allow current flow between the alternator the truck s battery bank and the additional battery bank 4 DC Cables are too long a The length of the cables used between the truck s battery bank and the APU battery bank needs to be as short as possible to prevent or eliminate any voltage drops that will prevent the AGM batteries from being fully charged 5 Battery connection points are contaminated a Battery posts on the truck s batteries as well as the battery posts on the APU batteries need to be serviced in order to maintain battery connection quality Battery connections need to be clean tight and protected 61 Truck Charge Circuit RF124 10 reasons that your AGM batteries are not fully charged 6 Alternator was replaced with the wrong alternator too small a The alternator needs to be gt 160Amps bigger is okay gt 200 is dangerous 7 A starter battery was replaced and the cables were left off or placed on the wrong connection point a When a second battery bank is added to a truck a battery separator is used to control the connection between the 2 battery banks If work i
7. charger Shore Power If the Purpose of this diagnostic s was to address a run time complaint a Turn on the Idle Free air conditioner b Use the AMP meter and clamp the Red cable between the battery separator and the Bussman fuse located above the battery separator c The DC Amperage should be between 35 and 45 Amps DC d The amperage could be much higher if the air conditioner has been running more than 1 minute without the condenser fan running APU Cover is off Turn off the air conditioner as soon as you have taken the amperage reading to prevent compressor damage If the testing so far has resulted in a change in the truck s battery bank or the results of the testing has revealed a good battery charge system from the truck a Check the underside of the APU and check to confirm that 5 battery bolts are present that run down the middle of the box these are used to hold down the batteries via the battery hold down bar b If any bolts are missing the batteries need to be removed to ensure that battery movement has not resulted in loose or broken battery to battery cables 9 58 Battery Test Procedure RF123 AGM Batteries Test the Truck Charging Circuit 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 If all battery hold down bolts are present remove the cables from the 1st battery Test the battery using the Midtronics battery tester If the 1 battery shows BAD remove all batteries and
8. count the lights lit If the truck is not plugged into shore power 3 or 4 lights will be lit Use a standard ended extension cord amp plug it into the trucks shore power plug exterior Go back to the Idle Free voltmeter and confirm that the number of lights now lit is more than the previous check step 1 Turn the truck s ignition key to ON without starting the truck s engine Locate the truck s dash voltmeter and confirm that the voltage is above 13 0 VDC Compare the dash display voltage with the Idle Free voltmeter and confirm that both meters are reading the same or close voltages Turn the truck s ignition Key to the OFF position Note make sure that the truck s engine has been running prior to testing the Idle Free Coolant Heater The cooling system must be purged of air to allow proper heater operation Heat Option 4 on Locate the Idle Free Thermostat Slide the Fan switch to the ON position The Idle Free closet located evaporator fan should be operating Slide the switch back to the Auto position Located the Truck s OEM bunk blower controls Move the Truck s bunk fan switch to medium speed and confirm that the bunk fan is not operating Slide the Idle Free Thermostat s Mode switch to the HEAT position a The Truck s bunk blower fans should now operate in all speeds b The exterior located coolant heater should be operating Note to driver the thermostat does not control the bunk temperature i
9. disconnecting a problem exists in the truck s charge circuit When the battery separator continues to close and then open the battery separator is closing at 13 2VDC however the combined battery voltage both battery banks drops to below 12 8VDC and the separator opens This condition can be caused by 1 Bad Starter Battery 2 Loose Cable Connections 3 Alternator too small 4 Either battery bank deeply discharged If one of the battery banks has a DC voltage of 11 5 VDC or less it is recommended that the batteries in this bank be tested individually It is common to find that the truck s battery bank contains a bad starter battery A bad truck starter battery will not allow the Idle Free AGM batteries to properly charge Replace defective truck starter batteries Loose or un connected battery cables will not enable AGM battery charging DC Voltage Display RF102 Current DC Voltage Level of IFS AGM Battery Bank DC Volt Meter IFS Part H 32026 Component Location Truck Interior Bunk Area Connected to the back side of the UBB REF Sheet 63110 ef a Description amp Application The DC Voltmeter is used as an Idle Free AGM battery Fuel Gauge The DC Volt Meter is connected to the Under Bed Module RF110 The flat magnet is located on the back side of the DC Voltmeter The DC Voltmeter has a 6 foot cord used to enable the use of the Voltmeter in the driver s living area Overview The Voltmeter is divided in
10. gt 12 7VDC If no voltage is present check for DC voltage on the GREEN male connector on the DC input side of the APU previous page If alternator voltage is present gt 12 7 VDC clamp the AMP meter around the cable connecting to the Truck Battery Post The DC AMPs should be proportional the DC Voltage High AMPs Low Volts If no amperage is read on the meter understand that the battery separator is not closed or is not connected to the AGM battery bank The truck s voltage must be higher than 13 2 VDC to activate the circuit board that will close the battery separator when the truck s battery voltage rises to 13 2 VDC or higher If the battery separator is working 1 The voltage on both top posts will be the same 2 The amperage read on the clamp meter will be the same on the truck battery cables as the amperage reading on the AGM battery cable 3 The voltage and amperage will be proportional to each other an Amperage reading of 100 AMPS DC will mean a low alternator DC Voltage 13 0 VDC The Battery Separator will operate close based on a voltage rise from either the truck s battery bank or the AGM battery bank The Idle Free AC to DC Power Converter Shore Power RF104 is connected to the AGM battery side of the battery separator When shore Power is being used the AGM side of the battery separator will control the closing of the battery separator Battery Separator RF101 Component Description amp Application Component
11. life expediency of the battery separator is dependent on e Size of the alternator e Condition of the batteries connected to it e Battery cable connection quality Service See IFS Doc 63004 APU DC Connections Clean Battery cables connections Tighten Battery Cable Connections Protect Battery Cable connections with Battery Corrosion Protection Spray Clean and Tighten amp Protect Circuit Board Ground wire bottom terminal Battery Separator RF101 Component Description amp Application F j ief a y al H H I 15 f DE Input Connection Poi nts IFS under bed Box UBB DC Panel Mounts locited on the rear side of the APU 11 IFS 46M Battery Bank Battery Separator a Ground wire push on female terminal connects to i te go the bottom terminal post Teme ee eee Battery Separator RF101 Component Description amp Application Battery Separator IFS Part 35004 Ie Post Component Location APU exterior Top Level front Above outside battery AGM Battery Post Tools Needed DC Clamp AMP Meter DC Volt Meter Ground Terminal Component Check Procedure Check for DC voltage on the truck battery post on the top of the battery separator Use the ground terminal on the battery separator for the meter s ground lead This voltage is the truck s starter battery voltage If the truck s engine is running this voltage should be alternator output voltage
12. receiver Three colors are used in the Idle Free system 1 Red APU fused power from APU AGM Battery bank to UBB 2 Green Truck Alternator starter batteries to APU 3 Black Ground from Truck battery bank to APU Ground to UBB from APU The Cam Lock Panel mount connectors can be moved from one side of the APU to the opposite side Plastic plug inserts can be removed to allow the re location of the Panel Mount Cam Lock Connectors Common Issues The Cam Locks need to be locked in place to ensure proper energy transfer The Cam locks need to be inserted and twisted to the right to lock them in place Service The Cam Locks need to be serviced to ensure clean connections tight connections and treated connections Use an anti oxidant di electric grease to prevent connection deterioration E IFS AGM Battery Bank Battery Separator L 45 DC Cam Lock Connectors RF117 Current DC Voltage Level of IFS AGM Battery Bank This Page Intentionally Blank 46 Refrigerant Quick Connects RF118 Description amp Application Refrigerant Quick Connects Component Location APU Exterior behind APU Part s Male 6 54207 Female 6 54201 Male 8 54208 Female 8 54202 Description amp Application The Refrigerant Quick Connects enables the air conditioner s evaporator and compressor units to be separated without having to remove the 134A refrigerant from the completed system The Refrigerant Qui
13. se E IFS 63003 REV2 71 120 Volt Connections APU Picie Service Procedures e Thermostat must be in the OFF position Pressure Switch Connections 2 female push on black wire 1 Remove pressure switch drier connectors 2 Clean pressure switch terminals 3 Tighten crimped female push on terminals using a needle nosed pliers tighten to near closed 4 Return crimped and tightened terminals to the pressure switch terminals 5 Spray pressure switch connection points with the battery terminal protection spray Pressure switch should look like this after the terminals are removed cleaned tightened Pe replaced and treated with alba battery terminal protection reventative Original Aed Formula spray IFS 63003 REV2 12 120 Volt Connections APU liefe Service Procedures fief Thermostat must be in the OFF position Harness input White to Blue Neutral 1 Locate Neutral wire on IFS 120 volt air conditioning harness The neutral wires are connected in line above the drier white wire connected to a blue wire male pushed into a female 2 Clean both connectors terminals 3 Tighten female terminal using a needle nosed pliers tighten to near closed 4 Connect crimped and tightened terminals together 5 Spray pressure switch connection points with the battery terminal protection spray AL TUD il lib ap niji an mer ye AA SANO av FR Battery Corrosion
14. sends fused 12VDC power from the ignition source to the UBB The Ignition Cut out circuit cuts the 12VDC power to the Thermostat when the truck s engine is running Issues 1 The Ignition Cut out circuit has been installed incorrectly on rare occasions When the installation instructions are not followed the ignition cut out circuit is connected to the accessory circuit instead of an ignition only circuit This causes the Idle Free air conditioner ee Dee ae or heater to shut off whenever the truck s ignition key is moved to unto APU the accessory position When the user wants to listen to the radio lt CAINE E the Idle Free system shuts down EL Hsi 2 The Idle Free system user turns the ignition key to the ON position without turning the air conditioner to the OFF position thermostat A When the user turns the ignition key back to OFF the Idle Free air lS conditioner is forced to start without a 5 minute delay Delay is built into the Thermostat The Idle Free air conditioner start attempt forced under these conditions may overload the inverter RF105 Ignition harness plugs into the back of the UBB Service ruse The Ignition circuit does not require service ae Thermostat The Ignition cut out fuse location varies by truck application The Ignition cut out fuse is located within 12 inches of the ignition de gi connection point Freightliner and International trucks begin the ignition cut o
15. test each one If the first battery shows GOOD a Putthe battery to battery cables back onto the front APU AGM battery leaving the cable that runs to the battery separator removed b Remove the rear APU Cover Connect the ground cable of the Midtronics Battery analyzer to the ground post of the rear battery d Connect the positive connector lead of the Midtronics Battery analyzer to the positive battery post on the front APU AGM battery e Test the group of batteries using the CCA function set at 2920 CCA If the test shows good inspect the connections on the batteries for contamination Clean the battery connections the battery separator cable connection points and the fuse connection points If the battery test shows GOOD BATTERIES CHARGE amp RETEST charge the batteries by plugging into shore power Continue the charge shore power until the amperage going into the battery bank is less than 10 AMPS DC If the Midtronic s battery analyzer showed that the batteries have low capacity remove the AGM batteries and test them individually using a CCA rating of 730 CCA Replace batteries that say REPLACE BATTERY Midtronics Battery tester Clean cables before placing them back into service Ensure that all connections are tight Use some type of battery protection spray to protect the new battery connection points Be sure to connect the positive cable between the battery separator and the first AGM battery prior to putting the APU covers back in place
16. the Idle Free inverter and other DC needs 4 Use battery corrosion protection spray into the bulk head connectors prior to re connecting the color matched male connectors into the bulk head connectors The bulkhead connectors will only allow the male plug to go in if the proper alignment is achieved Place a negative twist counter clockwise unto the cable connector prior to inserting it to ensure that the connector remains tight Twist each connector clockwise to lock them in place 50 RF120 DC Connections APU Service Procedures Thermostat must be in the OFF position Battery Separator il Inspect both terminals on top of the battery separator for cleanliness tightness and protection treatment The far post on top of the battery separator has a single cable and the closest post has 2 battery cables connected to it Remove the single cable from the far post first clean the cable end and the battery separator post Replace cleaned cable end to the far post and tighten securely Repeat the procedure 3 on the closest battery separator post 2 cables Treat the cleaned and tightened battery separator posts with Battery Corrosion protection spray Remove the rubber fuse cover and remove the fuse Clean the fuse ends ruse receiver terminals amp the cables ends that connect to the fuse Return the fuse to the fuse holder and tighten to ensure no cable movement Treat the cleaned and tightened fuse posts with
17. the inverter and starts the compressor only if the Start Capacitor contacts open ee ee eee eee A A A ee A A A A A If the inverter continues to overload and shut down after turning it on and Run Capacitor Top then off the start capacitor may need to be replaced cio The start capacitor can be checked by removing the start capacitor terminals I E Blue Wire from the run capacitor l i If the compressor starts the start capacitor is bad and needs to be replaced l Service i The start capacitor requires minimal service i The start capacitor connections points must be maintained by keeping the connections clean tight and treated to prevent contamination l Please use RF112 for service procedures i l dais Start Cap Wire Figure i ss gt gt ss gt SS SS a 99 Start Capacitor RF122 Air conditioner Start Capacitor This Page Intentionally Blank Battery Test Procedure RF123 AGM Batteries AGM Battery Testing Proper AGM battery testing is required in order to file a warranty claim Proper system diagnostics are needed to properly determine that the APU AGM batteries should be removed and tested Less that 2 of IFS AGM batteries fail in a 2 year period The truck s charge system should be checked for problems prior to pulling and testing Midtronics EXP1000 AGM batteries See Reference sheet RF124 Kit Link to instruction Manual If a truck is driven into a service c
18. two positions marked AUTO amp ON The AUTO position is used if the system user wishes to have the air conditioner s evaporator fan turn on and off with the air conditioning compressor circuit Leaving this switch in the ON position will continuously run the evaporator fan regardless of the compressor s current mode The driver should place the Fan Switch in the ON position for best system performance Placing the Thermostat Fan switch in the ON position will eliminate 10 of the Inverter start up power needs The IFS Thermostat has two soft push buttons located under the LCD Display The center soft button is used to display the current room temperature and turn on the display s backlight The right soft switch increases the temperature setting of the thermostat and the left soft button decreases the temperature of the room setting A low Voltage Battery Indicator Icon is shown on the display when the AA batteries need to be changed HEAT MODE The thermostat is used to turn on the Idle Free water heater and the Heat relay Relay Group RF106 The thermostat when in HEAT Mode provides 12VDC power to the Truck s Bunk Blower fan The Thermostat s temperature settings are not used in Heat Mode The truck s bunk controls are used to provide Bunk Heat temperature control Technical Information The Idle Free Thermostat can be separated from its mounting base The mounting base contains terminals for the wiring harness the runs between the th
19. watts needed to start the microwave Idle Free cannot control what is plugged into the inverter and the user needs to understand the inverter parameters 5 Drivers need to understand the Do s and Don ts when using the Idle Free air conditioner The inverter will display LED lights that will show the reason for the inverter shut down Learning to properly react to these indicators will eliminate most inverter issues 6 A permanent label sticker is affixed to the underside of the UBB Cover This information label contains helpful information for troubleshooting the inverter Inverter RF105 3 3 Protections Features 3 1 3 Input Level Display Input Voltages DC Input VDC Under Voltage Vol Shut A Shut E Restart Alarm E Restart dow dow re iso 02 m oes es oen gt 20 140 200280 s00 800 AA a O ORANGE Blink 14 0 14 7 280 294 56 0 58 8 ooo an as as Green LED LED Signal Status ee NC rowers IMEI ed MTC UIT MTM OP ss Troubleshooting guide LED Status DC 12V DC 24V DC 48V REDO 109 113 218 226 43 6 452 ORANGE 113 120 226 240 452 480 Model Over Voltage Under WARNING Do not open or disassemble the Inverter Attempting to service the unit yourself may result in a risk of electrical shock or fire Problems and Symptoms Possible Cause Solutions No AC Power Output STATUS illuminates the red LED a Blinking fast Over input voltage
20. 0VAC when the relay coil receives 12VDC power green wire from the thermostat The connection point for the Evaporator is the UBB back side 3 pin connector 2 from the top marked EVAPORATOR The outside pins are used to test for 120VAC power red and white wires 33 Evaporator Module RF111 Evaporator Module This Page Intentionally Blank 6 N Compressor Circuit APU RF112 5 A idlefree Compressor 120VAC Circuit Explanation Idle free wA fice Compressor Circuit e N ma rere ach Component Location 4 Truck Exterior E APU Frame Mount Connects to IFS APU Hames Top Level Harness Description amp Application The Compressor Circuit connects the following components together 1 Compressor Heat Overload switch Compressor Top Run Capacitor Start Capacitor Pressure switch drier top 6 In line neutral connection All components listed above use 120VAC ot a a Run Capsotor Overview 1 The 120VAC Circuit begins in the APU with 2 Black wires connected to the pressure switch located on top of the Drier top These connectors require a tight fit 2 The next connection in the Compressor Circuit connects 2 in line connectors together blue wire into a white wire using a male and female connectors push together type These connectors require a tight fit 3 The next connection point is the Run Capacitor The run Start Capacitor capacitor has 5 connections divided into 2 connection points Se
21. 3 Battery Connection Tools needed e 9 16 wrench or socket e 2 wrench or socket e Side Cutters Parts needed e Tie straps 8 inch narrow e Battery Protection Connection Spray Procedure Overview Remove cover from APU amp examine all DC cable connection points Ensure that all are clean tight and treated for corrosion protection Use a flashlight to check the Battery post connections that are located under the upper level The positive battery connections are subject to contamination as well as the cable crimps under the heat shrink cable ends Replace severely corroded battery cable ends or battery to battery cables Use battery Protection Corrosion spray on all DC Cable connection points LY APU Frame DC Cables APU 54001 Gen 3 5 Rev1 DC Input Connection Points IFS under bed Box UBB DC Pana Mounts located on the Feat side of the APU IFS AGM Battery Bank Battery Separator 42 AGM RF116 AGM Battery Bank explained Thermostat must be in the OFF position The Idle Free AGM batteries will be in one of two locations under the air conditioner and water heater or in a between the frame battery box The Service Procedure for either type is the same Battery to battery Cables and Connection Points 1 Inspect all battery to battery cables looking for signs of corrosion or dirt If corrosion or dirt is present remove the battery nut and clean the lug and batter
22. Battery Corrosion protection spray 51 RF120 DC Connections APU Service Procedures Thermostat must be in the OFF position Truck Battery Box Connections Service Procedures 1 10 11 12 13 Remove the cover from the truck s battery box to expose the truck s starter batteries Locate the positive battery post with the Red Idle Free 12 battery cable attached to it 32041 Remove this Red positive cable from the battery post and clean the battery post and the Idle Free Battery cable lug Make sure and clean the face of the cable or the mounting face of the battery to ensure good energy transfer Place the cleaned Red cable back onto the cleaned battery post and tighten the battery nut until the cables attached to it will not move Locate the other end of the 12 Red cable that is attached to a fuse in a rubber fuse holder Remove both cable ends 32042 amp 32041 and the fuse in the fuse holder Clean the fuse connections points the battery cable lugs and the fuse itself Place the cleaned cables back into the fuse holder followed by the fuse Tighten the fuse holder nuts until the cables will not move Locate the negative battery post that contains the Idle Free Black negative cable 32044 Remove this Black negative cable from the battery post and clean the battery post and the Idle Free Battery cable lug Make sure to clean the face of the cable or the mounting face of the battery to ensure
23. Check Procedure continued If the Battery Separator is not functioning when either of the top posts has gt 13 2VDC remove the ground wire from the ground terminal Battery Separator terminal and place the negative probe from your volt meter into this terminal end of the ground wire Check for DC voltage on either Battery Post to confirm that a ground is present on the Ground terminal harness This test will ensure that the wire is bringing a ground to the battery separator s circuit board If a ground is present on the ground terminal wire suspect a bad battery separator Proper Diagnostic work needs to be done prior to replacing the battery separator The battery separator may be working if the battery voltage is below 13 2 VDC but above 12 8 VDC The Battery Separator will close its contacts when either of its battery posts rises above 13 2 VDC The battery separator will remain closed until the contacts drop to 12 8 VDC 12 7VDC E Not connected lt gt IRR rd Connected The Top Line Blocks represent the initial DC Voltage when the battery separator was open not connected and the filled in blocks show the battery separator connected The Second line shows what the DC Voltage can look like once the separator closes both battery banks will remain connected together until the DC Voltage drops to 12 8 VDC Component Check Procedure continued If the Battery Separator is connected for only a few seconds and then
24. NO NC amp o e Ground Ground Ground 12VDC a t 12VDC Thermostat O 12VDC Ignition source Heater signal Compressor signal Thermostat va 12VDC from the timer 8 h s BLUE vaporator signal GREY Thermostat Power Direction of YELLOW GREEN Red Current Flow This Row is Fused Idle Free Battery 7 p T Power 6 lt This Row is Fused I Truck Battery Power Heat Relay NO Normally This Row amp is the Open Normally Closed m oie pas Ys I This Row feeds the 12VDC to the component being controlled Relay Group RF106 Power Relays explanation RED From Truck Power source for Blower Motor From Truck Power source for Blower Motor Control From Truck Power source for Blower Motor Control YELLOW BLUE Wire from Thermostat To Blower Motor or Control YELLOW a O Evaporator amp Compressor Apo Relay Wiring OA BLACK Co al ee sees RELAYS Group ih LOA E ee A GREEN MEA A K S fecu mn Compressor Evaporator 120VAC Socket 120VAC Socket BACK PANEL UBB 19 Relay Group RF106 Power Relays explanation Thermostat so k al gt A RELAYS Ignition Relay Wiring Fused Ignition Source Compressor Circuit Delay Timer Troubleshooting Use the relay Black 18 gauge wires for ground service connections Ignition relay must be OFF not activated for an
25. Overview All components contained in the UBB and all components that plug into the UBB have their own reference sheets RF The underside of the UBB Cover includes a troubleshooting guide The UBB is used for diagnostic entry into the Idle Free system The Relay Group is tested to see if DC voltage from the Thermostat is reaching the relays The inverter GFCI reset is located on the end of the inverter located in the lower level of the UBB RF105 Common Issues The UBB has a history involving GFCI tripping of the inverter or red light conditions on the inverter These issues go away after the driver better understands how to properly use the system RF105 Service The UBB does not require any service however connection quality needs to be maintained and proper ventilation needs to be present around the UBB to allow for air flow to the inverter and the AC to DC Power Converter 29 UBB RF110 Under Bed Box Explained What is a GFCI GFCI is an acronym that represents Ground Fault Circuit Interrupter A GFCI continuously monitors the current in both the LOAD and neutral leads If a current imbalance of approximately 5mA is encountered a GFCI will trip opening the circuit This current imbalance often comes from a ground fault on either the LOAD or NEUTRAL circuit The ground fault comes from current travelling to the chassis through wiring components or even a person Contrary to popular notion a GFCI is not a load protecti
26. Preventative Original Red Formula Lt el a TTL ey A mad re AA asar a a g Ba nm 4 y iue Rots e Ye bas E IFS 63003 REV2 73 120 Volt Connections APU lefe Service Procedures Thermostat must be in the OFF position Run Capacitor 5 connections 1 2 3 10 11 12 13 Remove all 5 connectors from the run capacitor Clean all terminals Tighten the 2 Blue wires female terminals using a needle nosed pliers tighten to near closed Push both female blue terminals back onto the aluminum frame side run capacitor top and bottom posts Locate one of the black 18 gauge wires from the start capacitor mounted below the run capacitor Tighten the female connector end using the needle nosed pliers This step is critical and has been found to be a recurring problem lose start capacitor connections Push on the female start capacitor terminal to the open post on the same side along with the 2 blue wires Place a Tie Strap around these 3 connections and tighten Locate the removed red wire and the remaining black wire start capacitor Tighten both terminal ends using the needle nosed pliers red and black wires Install the tightened red and black capacitor wires onto the open side of the start capacitor Place the Red wire onto the lower post and the black wire onto the upper post The side post will not receive a terminal Place a Tie Strap around the red and black wire and tighten Spray th
27. TO Start or Continuous Run Remove the Idle Free Interconnect Cable set from the Driver s side Box Connect the Interconnect Cable to the Truck side of the ReeferLink Connector Connect the Interconnect Cable to the Trailer side of the ReeferLink Connector Turn On the Idle Free APU Air conditioner or Heat 65 Driver Orientation RF126 Reefer Link Connection The ReeferLink System Operation Guide Confirmation that the ReeferLink connection is working Reefer Unit Is Running e Reefer Alternator should display gt 13 1 VDC e Idle Free Voltmeter should show 4 lights or more Reefer is not running e Reefer Battery Voltage should display between 12 1 VDC amp 12 6 VDC e Reefer unit should automatically start when DC Volts drop to 12 1 or 12 0 When to use the Reefer Link Connection 1 When the Bunk requires air conditioning or heat 2 When If the reefer alternator fails 3 When If the truck alternator fails Reefer Alternator failure 1 Connect the interconnect cable set to the truck and trailer and route the set with the air lines or electrical trailer harness from the truck to the trailer 2 Keep both connectors in place as you drive until the reefer s alternator can be replaced 3 Secure the ReeferLink Cable set to ensure that it does not rub on the step deck 4 Make sure that the replacement alternator is at least 65 AMPS Truck Alternator failure 1 Connect the interconnect cables and route th
28. UE from run capacitor SPP7E IFS Part 34005 The original Supco Start Capacitor SPP7E was manufactured and installed into the IFS system with loose push on terminal ends that connected the Capacitor s circuit board to the capacitor body lower unit The loose start capacitor connections resulted in a Capacitor TSB IFS 1209181B The Capacitor TSB was the field fix and the Permanent fix was to solder the start capacitor terminals to the capacitor body This change over was put in place in mid 2012 Compressor Bracket Side mount The compressor side mount bracket is subject to failure by breaking at the joint where the side bracket attached to the compressor bracket Removing the bracket all together is one method of repair that has stood the test of time The part number for the replacement side bracket kit is IFS 31021 Compressor Top Tube The compressor Top Tube is subject to breakage when the output refrigerant hose is tied tight between the compressor top and the condenser coil connection point The prevention for this issue is to ensure that the refrigerant hose between the compressor and the condenser coil is not tied down and allows for freedom for play between the compressor and the condenser coil S RED from run capacitor C BLACK from pressure switch Run Capacitor Top Black Wire Blue Wire Service The Compressor does require a small amount of service just to make sure that the connector terminal ends a
29. air line connection point Truck to Trailer Interconnect Cable set The Truck to Trailer Interconnect Cable Set is typically kept in the driver s side box This connection can be made anytime however it is best practice to only mate the truck and trailer together when the need arises or when the truck is stationary The ReeferLink Connections require regular service This service includes 1 2 3 Checking for tight connections Checking for Clean Connections Adding battery terminal Dielectric grease to terminal connection points Troubleshooting The ReeferLink Connections can be checked using a DC Voltmeter 1 Check the Reefer side Anderson Connector for DC Voltage by placing the Voltmeter probes onto the lugs located inside the connector body The Anderson connector body has or indicator markings on the connector body near the terminal connection points If DC voltage is not present check the 125 AMP fuse alternator connection and the Reefer s Battery connections The truck side ReeferLink Connector should always show APU DC battery voltage Check the Reefer Link connector located on the back side of the bunk for 12VDC power If 12VDC power is not present check the APU panel mount connectors exterior of APU Remove the panel mount connectors Counter clockwise to remove clockwise to tighten You should always have 12VDC at the APU panel mount connectors If no DC is present remove the back cover from the APU and check
30. ase of the closet The Evaporator Module includes an aluminum filter rear location The Evaporator Module weighs 25 s Overview The Idle Free Evaporator Module is installed into the leaving area of the bunk Service The Idle Free Evaporator has a removable aluminum filter that must be cleaned water in order to maximize performance History of Issues The Evaporator must be maintained in a way that allows air to reach the rear side filter Keep driver s personal belongings away from the Evaporators air intake coil amp filter During installation ensure that the screws used to secure the evaporator are not driven through the refrigerant core or the blower motor Suggestion have user place the right Thermostat switch RF103 into the ON position not the AUTO position Leaving the Thermostat in the ON position when in Air Conditioning Mode will keep the room in a consistent temperature range Trouble Shooting The Evaporator Fan receives its 120VAC power from the Inverter The inverter must have a Green status light or a flashing green status light to enable the evaporator fan The Thermostat must have its fan switch in the ON position to activate this fan Sees motor OR the Thermostat must be in the COOL mode with a temperature set to Ert re 250A APU fuse is removed before below the current bunk temperature aR EA asta The Thermostat sends 12VDC to the Evaporator relay The evaporator relay UBB ice cube relay passes through 12
31. at this point should be only the DC components truck currently turned ON blower fan lights radio and such 3 The DC Amperage put out by the alternator should be less than 40 amps all truck accessories OFF after the truck has been started and after a period of 3 to 5 minutes 4 Amperage readings higher than 40 amps all truck accessories OFF should be researched further to determine if the alternator output amperage is being sent to a bad battery with a bad cell 5 With the truck s engine still running remove the APU cover and take the DC voltage on the first battery Voltage should be the same as the voltage read at the alternator If the voltage is more than 3 volts lower than the alternator voltage suspect poor connections loose cabling or other factors that are contributing to the voltage difference Test the truck batteries first History has shown us that poor truck batteries result in poor APU battery charging 1 Turn the truck s engine off and remove the surface charge from the truck s starter battery bank by running the truck s headlights for at least 10 minutes Do not test any batteries that have just been charged by the engine running or a battery charger Remove the battery cables from the truck s starter battery bank Use the Midtronics battery analyzer to determine the quality of each battery Replace any battery that lacks the correct capacity Check cable ends for cleanliness prior to putting all back onto the
32. attery power whenever the Heat relay is activated The Heat relay is activated by moving the thermostat mode switch to HEAT The Heat relay is wired to use the normally closed contacts and the normally open contacts within the relay When the thermostat is set to the HEAT mode the 12 VDC coil is activated and 12VDC fused power from the Idle Free battery bank is sent through the relay to the Truck Fan motor and fan control circuits 1 3 When the relay is not activated Heat switch is OFF or ignition switch is ON the normally closed circuit passes through the truck s blower fan power needs with 12 VDC Truck Battery Power The 3 circuits in this relay are not all used for every truck Instructions are included in the installation manual regarding the circuits needed for each truck brand installation application Overview The Relay Group is controlled by the Thermostat The Thermostat RF103 sends 12VDC signals to the individual relays in the Relay Group The Relay Group contains Ice Cube Relays Ice Cube type Relays enable the use of both ac and dc voltages through the relay contacts Common Issues The Relay Group has no history of issues Service The Relay Group does not require any service Relay Group RF106 Power Relays explanation IE Not Used 120VAC Top View of Relay Inverter source Group Direction of 12VDC Fused Current Flow Purple o o m Ea amp Heat Relay IGN
33. ature drops below 180 degrees When the engine block thermostat is closed the size of the coolant system is decreased When the Idle Free Heater Module is activated the truck s bunk blower fan is powered by the Idle Free battery bank RF106 The Water Heater Module s coolant pump is running 100 of the time that the Thermostat Mode switch is in the HEAT position Dosing Pump The Idle Free dosing pump fuel pump is mounted on the rear wall of the APU The electrical connection is made using 2 wires The dosing pump has 2 speeds The speed of the dosing pump determines the output of the heater The temperature requirements for the coolant heater determine the speed of the dosing pump heater output Fuel Filter amp Fuel Circuit The in line fuel filter is attached to the input side of the Idle Free dosing pump The fuel line feeding the fuel filter begins at the fuel pick up tube on one of the trucks fuel tanks Coolant Circuit The Idle Free Heater Module is plumbed in series with the trucks bunk heater core coolant circuit The truck is plumbed so that the water heater s coolant inlet circuit begins at the rear of the truck s engine The engine s coolant runs through the Idle Free water heater the bunk s heater core and returns to the engine block Common Issues The Water Heater Module is trouble Free however issues exist that prevent the heater from starting after a period of non use The fuel filter needs to be checked to make s
34. capacitor and a compressor The Evaporator Relay sends its power to the Evaporator module to power the single speed 120VAC Blower fan typically located in a bunk closet Component History Issues 1 GFCI will trip occasionally when Idle Free system is turned off suddenly by starting the truck The user manual instructs the driver to turn OFF the air conditioner with the Thermostat Only 2 The Inverter may over load Red Light condition if the Start Capacitor is not properly connected to the run capacitor The connection quality is a factor especially after a year of operation Service is required for the electrical APU Harness Clean Tight Corrosion application for all APU electrical connections 3 Inverter may shut down if 1500 watts is exceeded or 3000 watts surge is exceeded The Inverters maximum output is exceeded when the air conditioner is turned off for a few seconds and then back ON by turning the Ignition key ON and then OFF This action forces the air conditioner to attempt to start however the pressure present on the high side Freon circuit may be too high for the inverter output to overcome The correct USER procedure is to turn the air conditioner off using the slide switch on the face of the thermostat 4 The inverter may overload if a microwave is used that exceeds the maximum output rating of the inverter This tends to be the case on any microwave rated at gt 700watts The microwave rating is based on run watts not the
35. ck connects enable the correct amount of refrigerant to be placed into the air conditioning system at the time of manufacture Overview The Refrigerant Quick Connects includes the R134 Refrigerant Service Ports that are located within 12 inches of the rear of the APU The Refrigerant connections between the evaporator refrigerant circuits use a male to female threaded valve connection that opens the refrigerant circuit between both components when the two are threaded together The service ports used are standard 134A refrigerant service ports The amount of 134A used in each system is one of 2 levels e 2 8 pounds e 2 0 pounds The exact Freon level is posted on the APU rear wall under the cover The rule of thumb is e 6inch accumulator 2 0 pounds 134A e 12 inch accumulator 2 8 pounds 134A Common Issues The Refrigerant Quick Connects need to be properly connected during the installation process Refrigerant Oil needs to be added to the connector seals prior to joining the 2 connectors together Partially connecting the 2 Quick Connect parts together results in fittings leaking refrigerant or a high Compressor Head pressure reading 47 Refrigerant Qui ects RF118 umes as ication This Page Intentionally Blank RF120 DC Connections APU Service Procedures The Idle Free DC Circuit APU Exterior requires service to ensure proper system operation and performance When the Idle Free APU DC connections are dirty or l
36. correct battery posts SB M 57 Battery Test Procedure RF123 AGM Batteries Test the Truck Charging Circuit 1 2 3 10 11 12 13 14 15 Remove the cover from the APU Locate the battery separator use the link to the reference guide if needed Check the voltage on the single cable connection point on the top of the battery separator a The voltage reading is the truck s battery voltage and should be the same reading as voltage taken directly on one of the truck s starter batteries If the voltage is different lower check the DC connection points between the truck s battery bank and the APU battery separator The connection points include i Green panel mount connector on the side of the APU or battery box ii Green CamLock connector plugged into the green panel mount connector iii Fuse holder Bussman located in the truck s battery box iv Positive cable connector located in the trucks battery box v Ground cable 32044 truck s battery box or on the frame behind the truck s batteries vi Ground cable black connector connected to the black panel mount connector side of the APU If the voltage is the same start the truck and take the voltage reading again on the single cable connection point on the top of the battery separator The voltage reading should show alternator voltage of greater than 13 0 volts When or if the voltage reading is above 13 2 VDC the battery separator should close and th
37. e APU batteries will be connected to the truck s batteries Check the voltage on the double cable connection point 2 cables on this post on the top of the battery separator a The voltage on both battery separator top posts should display the same voltage when the battery separator is closed b The voltage displayed if both banks are connected will be gt 12 8 VDC The actual DC Voltage will be based on the charge condition of the AGM battery bank This will be the case because the truck s battery bank has already been checked a Ifthe battery separator DC voltage shows to be near 14 VDC the battery charge circuit from the truck is working properly The remaining factors that determine if the APU batteries need attention are the cable connections between the APU batteries Turn off the truck s engine Plug the truck into shore power The Idle Free battery charger should now be ON Check the voltage on the double cable connection point 2 cables on this post on the top of the battery separator a The voltage on both battery separator top posts should display the same voltage when the battery separator is closed b The voltage displayed if both banks are connected should be gt 12 8 VDC If the Idle Free battery charging is working the voltage should be at least 12 8 VDC d A voltage reading gt 13 5VDC means i Battery charger is working ii APU AGM Battery bank is nearly full iii Battery separator should be closed Unplug the battery
38. e figure 2 These connectors require a tight Figure 1 fit 4 The next component is the Start Capacitor The start Capacitor is connected to the Run Capacitor using the 2 black wires see Figure 2 5 The next connection is the Compressor Top connections 4 connectors are located under the plastic cover The Heat overload switch receives the Black wire from the drier top The short wire that leaves the overload switch connects to the C terminal on the compressor Top The Red wire from the Run Capacitor connects to the Top of the Compressor onto the S terminal The remaining Compressor top terminal is the R terminal and this terminal receives the Blue wire from the Run Capacitor These connections require a tight fit IE TE re aan II Ii Ia E A Run Capacitor Top Black Wire Blue Wire Blue Wire Red Wire Common Issues History Black Wire The Compressor circuit has 2 areas to focus in on Start Capacitor and Pressure switch Drier top connections These connections are the focal point when the compressor fails to start Figure 2 35 This page intentionally blank DC Wiring APU RF113 Water Heater amp Condenser fan Wiring DC Wiring APU Component Location APU Exterior Top Level Fuse Holder to Component Condenser Fan Relay 120VAC Coil Description amp Application The APU DC Circuit consists of 1 Fuse Holder with 2 circuits a Water Heater 20 AMP b Condenser Fan 15 AMP 2 Water Heater Po
39. e run capacitor connection points with the battery terminal protection spray Tie strap in place on first set of run capacitor terminals contains 2 blue wires and a back wire from the start capacitor Run Capacitor with all terminals in place 2 Ties straps are used each set of terminals is tied separately IFS 63003 REV2 gISoSPZEpZE co an TU a DIXENSZWPZH SSedsze y 74 120 Volt Connections APU Service Procedures idle free Compressor Top 4 connections oo Se O N Du Remove the screwed on cover from the compressor top Check the tightness and cleanliness of the connections If the 4 connectors are clean and tight do not remove them from their connection point If any one of the connections is lose remove it and use the needle nosed pliers to tighten the connector place the tightened connector s back on to the appropriate terminal post a Black C b Red S c Blue R Spray all compressor terminals with battery corrosion spray Install cover do not over tighten If the cover is cracked replace the cover Secure all lose wires with tie straps End of procedure Battery Corrosion Preventative Original Red Formula IFS 63003 REV2 75 This Page intentionally blank 7 78
40. ect the 12VDC connections truck and reefer trailer together 27 ReeferLink Connection RF109 ReeferLink Explanation Overview continued The Idle Free Reefer Link system will allow the reefer unit to start from the Idle Free APU batteries directly by connecting the reefer trailer to the truck using the ReeferLink interconnect Cable set Using the ReeferLink Connection to power the APU has the benefit of using nontaxed fuel for non road use ReeferLink Connection Kit consists of 4 parts 1 APU DC Connection cables internal and panel mount receptacles fused The APU has internal cables added along with DC panel mount receptacles The added panel mount receptacles added to the side of the APU provide a quick connect point for the truck side of the ReeferLink Connection Kit The APU DC Connections are fused with a 250 AMP fuse to protect the truck and trailer 2 Service Truck connection connector body 8 cover The truck connection portion is mounted near the connection point on the back of the bunk where the air hoses and electrical cord is housed for the standard truck to trailer connections Trailer connection connector body 8 cover fused The trailer connection kit includes a 250 AMP fuse used to protect the truck and reefer unit from short circuits The trailer portion of the ReeferLink Connection uses a permanent mount for the Anderson connector This mount is typically mounted near the electrical plug in and the
41. el The positive battery connections are subject to contamination as well as the cable crimps under the heat shrink cable ends Replace severely corroded battery cable ends or battery to battery cables Use battery Protection Corrosion spray on all DC Cable connection points 49 RF120 DC Connections APU Service Procedures Thermostat must be in the OFF position The Idle Free AGM batteries will be in one of two locations under the air conditioner and water heater or in a between the frame battery box The Service Procedure for either type is the same Battery to battery Cables and Connection Points 1 Inspect all battery to battery cables looking for signs of corrosion or dirt If corrosion or dirt is present remove the battery nut and clean the lug and battery terminal If the battery connection looks clean check the battery nut to make sure that the battery cable does not move Bulkhead Connectors 1 Remove the rear cover of the APU to reveal the DC Bulkhead connectors located on the rear side of the APU Disconnect all exterior rubber connectors by twisting them counter clockwise and pulling them out 2 Inspect the panel mount connection points to ensure cleanliness amp no signs of corrosion Repeat this procedure with the male plug in connectors 3 The Black bulkhead connector is ground the Green is truck battery bank fused power and the red connector feeds the Under bed module with fused DC power for
42. em with the air lines or electrical trailer harness 2 Keep the connector in place as you drive until the truck s alternator can be replaced Secure the ReeferLink Cable set to ensure that it does not rub on the step deck 4 Make sure that the replacement alternator is at least 160 AMPS 66 8 second 5 minute Delay Circuit RF128 Description amp Application 8 second 5 minute Compressor Delay Circuit 8 second 5 minute delay circuit is Component Location factory installed starting 12 05 2014 UBB Top Shelf Back Wall IFS Serial Numbers gt 36U14120512 Part 37022 The relay delay timer 37022 will delay the compressor activation 8 seconds amp will include a 5 minute delay circuit that will prevent the compressor from starting for 5 minutes anytime power is cut to the compressor circuit 37022 Delay Timer UBB 5 min Delay Timer relay 37022 eliminates compressor hard starts caused by the truck s ignition being turned on for less than 5 minutes Delay Timer relay 37022 uses 3 terminals instead of 2 terminals used on Delay Timer relay 37020 previous delay method used prior to this one Delay Timer relay 37022 is wired 1 To the Compressor Relay yellow 18 gauge wire 2 From the Thermostat yellow 18 gauge wire 3 To the Heat Relay ground connection point black 18 gauge wire Diagnostics Question Has the truck s Ignition Key been moved to the ON position in the last 5 minutes The
43. en the inverter is in stand by mode or if the inverter is turned off or if the GFCI outlet is tripped 3 1 4 Load Level Display AC Loads Watts GREEN ORANGE RED RED BLINK SK1500 0 120W 120 495W 495 1125W 11125 1450W Over 1450W status Normal Power Saving Mode Plugged into shore Power or Reefer Running OKAY Out of Battery Power Overheated ventilation Inverter was over loaded Bottom Light Status Light This light is the key to what is happening to the inverter and knowing its status will help determine what the fix is Inverter RF105 GFCI Reset Procedures 1 2 Lee YE Locate the GFCI Outlet found on the end of the inverter Turn the inverter OFF using the black switch located to the left of the white 120VAC outlet Turn the Inverter ON using the black switch located to the left of the white 120VAC outlet Push the Reset Button in within 5 seconds of turning the inverter switch to the ON position OR Locate the GFCI Outlet found on the end of the Inverter Push and Hold the Reset Button IN Turn the Inverter Switch to the OFF position Turn the Inverter Switch to the ON position Holds reset button IN until you feel it Click Reset Button Power Switch GFCI Indicator Light Note on some Inverter models the GFCI indicator light is located in this location Inverter RF105 Inverter Diagnostics The Idle Free Inverter has all the indicator
44. enter and the AGM battery voltage is taken shortly after the truck s arrival the APU AGM battery voltage should be at least 12 7 VDC If a voltage reading is taken that shows less than 12 7 DC volts the problem is probably the truck s charge system not the AGM battery bank The AGM battery bank s present voltage may be a result of an inadequate truck charge circuit not necessarily a result of a bad battery s that need s to be replaced It is common to have a Dealership diagnose that an AGM battery bank has failed replace the battery bank return the AGM batteries to Idle Free Idle Free analyzes the AGM batteries and determines that the batteries are undercharged not bad or in a replaceable condition Determine why the AGM Batteries are underperforming Do Not Remove the AGM batteries without first determining if the problem is the truck s charge circuit Tools needed e DC AMP Meter e Voltmeter e Battery Analyzer 1 Start the truck and take the alternator output voltage at the trucks alternator Since the truck probably just drove in the Voltage output should be 14 0 VDC 2 Ifthe alternator output voltage is lower than 13 8 VDC use a DC Clamp AMP meter and determine the DC AMPs running through the alternator s positive cable Since the truck probably had driven to the service location the truck s batteries and the AGM batteries shown have already been charged by the alternator This would mean that the amperage seen
45. ermostat and the UBB REF Sheet 63110 The Thermostat is used to operate the Relay Group located in the UBB RF106 The Thermostat is supplied with 12VDC Power from the 2AMP fuse located on the front of the UBB RF108 The 12 VDC power enters the thermostat base on the red wire R terminal Jumped to a second R marked terminal The thermostat switch positions determine where how and when 12VDC power is sent to the UBB Relay Group e G Terminal Green wire 12VDC to the Evaporator Relay e YTerminal Yellow Wire 12 VDC to the Compressor Relay e Bterminal Blue Wire 12VDC to the Heat Relay The back side of the Thermostat includes 3 DIP switches that need to be in the proper position for the Thermostat to Function Properly 1 CONV HP HP 2 F C F 3 HE HG HG Common Failure Issues User fails to understand that the left Mode switch in A C mode has a 5 minute delay between ON then OFF then ON This causes confusion and is dealt with by instructing the driver to place right switch in the auto position to see if the Thermostat is in the 5 minute delay window If the evaporator fan is not running when the Mode switch is in COOL mode the thermostat is in the 5 minute delay mode Drivers need to operate the Thermostat with the Fan Switch in the ON position The ON position eliminates the need to start the Evaporator Blower fan and the compressor at the same time Thermostat RF103 Thermostat Description Fact Switch Default 4 Thermo
46. faults codes 5 and needs to be reset RF 114 Water Heater Power Plug Condenser Fan Power Plug 37 DC Wiring APU RF113 Water Heater Condenser fan Wiri This Page Intentionally Blank Water Heater Module RF114 Water Heater Module Explanation Water Heater Module IFS Part 42001 Component Location Truck Exterior APU Top Level Left side Description amp Application The Idle Free Water Heater is located in the APU Exterior The Water Heater consists of 1 Webasto TSL17 Coolant Heater 2 Dosing Pump Fuel Pump 3 Fuel Filter amp Fuel Circuit 4 Coolant Circuit The Webasto TSL17 is a 17 000 BTU coolant heater that is connected to the engine s coolant circuit When the truck s engine is running the engine s coolant is circulated through the engine block cab heater core Idle Free Coolant Heater and bunk heater core When the truck s engine is shut off and the Idle Free Heater Module is turned ON the engine s coolant continues to flow through the Engine Block and both Heater cores Cab amp Bunk by means of the 12VDC circulating pump attached to the Webasto TSL17 Coolant Heater The Water heater monitors the coolant s temperature as the coolant flows through the truck s coolant circuit Once the truck s coolant temperature drops to 138 degree F the Water Heater begins its start up cycle The truck s engine thermostat will close when then engine s coolant temper
47. for loose or missing connection points History of Issues The ReeferLink issues include Cables between the truck and trailer un secured during driving periods resulting in lost or broken cables Wrong DC connection point battery instead of alternator resulting in the reefer s control display showing a fault code 28 UBB RF110 Under Bed Box Explained UBB Under Bed Box or Under Bed Module Component Location Truck Interior Bunk Area Under Bed Floor mounted a t Description amp Application The UBB Under Bed Box is the connection module for the Idle Free System Ea ER The UBB contains the following components ml A S amp S OEM HVAC UBB to APU 1 Inverter RF105 x 2 AC to DC Power supply Shore Power RF104 ao E 3 Bn ap 3 Relay Group RF106 QE a ES y 4 DC Fuse Holder RF108 Be site ignition Voltmeter 5 Timer Relay Compressor Circuit RF106 The back side of the UBB Box contains connection Hubs for the following Components Caution 1 DC Cables From APU RF113 Ensure 250A APU fuseis removed before 2 Ignition Harness RF107 servicing Nigh amp de connections 3 Volt Meter RF102 4 Thermostat RF103 Positive 5 Evaporator Fan RF111 6 Shore Power Harness Connection point from Power inlet plug 7 Compressor Circuit includes water heater signal wire Blue 8 120VAC 10 AMP connection socket 9 OEM HVAC Fan harness connections for Truck bunk blower fan RF106 egative
48. ge The Power Converter has a rated amperage output of 55 AMPS DC The Idle Free air conditioner uses less than 50 AMPs DC and when using the Power Converter Shore Power the AGM battery voltage level maintains 12 6 VDC or higher Whenever the Power Converter s DC voltage rises past 13 2VDC the Idle Free Battery separator closes and connects the Idle Free battery bank to the truck s battery bank Battery Separator RF101 If the combined voltage of both battery banks remains above 12 8VDC both battery banks will remain connected and both Battery banks will receive a charge from the Idle Free Power Converter The Power Converter s 120VAC circuit begins on the truck s exterior with a covered receptacle male that is used to receive the female end of an extension cord The Power Converter s DC circuit begins at the bulkhead DC Connection posts on the lower back corner of the UBB UBB RF108 Potential Issues 1 Installer connects a ground power supply cable to the wrong or battery post This action causes the Power converter s DC fuses to fail The 2 30 AMP fuses are located on the rear side of the Power Converter 2 Shore Power plugging in is perceived to be a direct use of 120VAC power that directly powers the 120VAC Idle Free air conditioning circuit Shore Power is only used to convert AC to DC The inverter is always the 120VAC power provider for the Idle Free air conditioner Truck Batteries EA Pa Pa ad
49. good energy transfer Place the cleaned Black cable back onto the cleaned battery post and tighten the battery nut until the cables attached to it will not move Treat the cleaned and tightened Battery posts and fuse holder with Battery Corrosion protection spray 52 Drier Pressure Switch RF120 Drier amp Pressure Switch Receiver Drier Receiver Drier IFS Part 53301 Pressure Switch IFS Part 37015 ey i ii Component Location Truck Exterior APU Top Level Pressure Switch Description amp Application The IFS Pressure switch is located on top of the drier It is a binary switch that opens its contacts when no zero pressure is present or opens its contacts when high pressure is reached The contacts on the pressure switch need to be checked to make sure that they are tight clean and protected The use of battery protection spray is important on the pressure switch because of the contacts when contaminated potentially can leak Issues History The pressure switch may cause the GFCI to trip if 120VAC current leaks to the drier fitting The pressure switch should be replaced if the contacts are tested and continuity is not present when refrigerant is seen in the sight glass below the pressure switch Service The contacts on the pressure switch need to be checked to make sure that they are tight clean and protected RF Sheet 130 The use of battery protection spray is important on the pressure switch because
50. itioner The use of the inverter forces the unit to shut down when the AGM batteries reach 11 0 VDC Battery terminals will become corroded if they not treated with battery protection spray Service The AGM Battery bank requires regular Service to maintain connection quality The service required is specified on the following pages Clean Cables Tight Cables Treated Cables 41 AGM RF116 AGM Battery Bank explained The Idle Free DC Circuit APU Exterior requires service to ensure proper system operation and performance When the Idle Free APU DC connections are dirty or loose the Idle Free inverter s GFCI may trip or the Inverter may overload amp shutdown A poor dirty or weak DC connection will prevent the Idle Free batteries from charging and will limit the energy available for adequate air conditioner starting An overloaded inverter shown with a red status light face of the inverter may be caused by a loose or dirty DC Cable A loose DC Connection will reduce the available energy needed to start the air conditioner The Idle Free Inverter s GFCI outlet may trip due to dirty connections leaking voltage back to the inverter Service APU DC Connections Service Needs Clean tighten and Protect all DC APU connection points Connection Points 1 Battery to battery Cables 6 2 Bulkhead Connectors 4 3 Battery Separator 2 4 Fuse 2 Truck Battery Box 1 Fuse 2 2 Battery Connection
51. ive battery bank feed is from the front of the battery bank and the Negative battery bank feed is from the opposite end back or rear The battery bank is fuse protected with a 250AMP fuse located above the battery separator RF101 The 4 AGM batteries are held in place with a battery hold down bar Overview The AGM battery bank is dependent on the charge from the truck s alternator whenever the truck s engine is running The minimum alternator rating is 160 AMPS DC The Idle Free AGM batteries are dependent on the quality of the truck s starter battery condition and connections Service is required on the Idle Free AGM batteries The battery service includes the battery connections in the Truck s starter battery box The AGM batteries are charged by the truck s alternator when the truck s engine is running The Idle Free Battery Separator RF101 connects the truck s battery bank to the AGM battery bank when the truck s batteries gt 13 2 VDC The AGM batteries are charged when connected to a shore power connection RF104 The AGM batteries are charged using the ReeferLink Connection RF109 if when the truck is connected to a reefer unit Common Issues Less than 5 of all Idle Free AGM batteries fail to reach the 2 year warranty The Idle Free system includes Shore Power Shore Power when used keeps the batteries conditioned and extends AGM battery life The Idle Free system uses an inverter to power the Idle Free air cond
52. le Free battery separator when the Idle Free battery bank rises to 13 2VDC The truck and trailer can be connected ReeferLink Connection when the truck is moving in the event that a Truck s alternator fails b Reefer s alternator fails The trucks alternator can be used to keep the reefer units 12VDC systems operating by using the ReeferLink Connection The reefer unit s alternator can be used to keep the truck s 12VDC systems operating by using the ReeferLink Connection The Reefer Unit must have an alternator rating of 65 AMPS or greater The reefer connection kit reefer portion includes a 250 AMP in line fuse The reefer connection kit reefer portion DC connections must be made in this way connect the negative cable to the reefer battery negative post amp connect the positive reefer connect positive battery cable to the positive output post on the alternator The alternator must be rated at 65 AMPS or greater The positive connection must be made at the reefer alternator positive output post Overview The Idle Free Reefer Link system is a controlled DC connection between the truck and the reefer unit The ReeferLink connection provides battery charging for the Idle Free APU In addition the controlled DC connection between the truck and the trailer allows the truck or the reefer unit to supply power to each other In the event that a truck alternator or a reefer alternator fail the ReeferLink connection is used to literally conn
53. le free Idle Free Systems Inc Reference Guide System Component Information 68004 REV2 12 20 2014 68004 REV2 12 20 2014 RF RF101 RF102 RF103 RF104 RF105 RF106 RF107 RF108 RF109 RF110 RF111 RF112 RF113 RF114 RF115 RF116 RF117 RF118 RF120 RF121 RF122 RF123 RF124 RF125 RF126 RF128 RF129 RF130 Idle Free Reference Sheets System Components amp Trouble shooting Table of Contents Page 1 Battery Separator 5 DC Voltage 7 Thermostat 9 Power Converter 11 Inverter 17 Relay Group 23 Ignition Cut out 25 DC Fuse Holder 27 ReeferLink Connection 29 UBB 33 Evaporator 35 Compressor Circuit 37 DC Wiring APU 39 Water Heater Module 39 APU 41 AGM Batteries 45 Cam Lock Connectors 47 Refrigerant Quick Connectors 49 DC Connection Service 53 Drier amp Pressure Switch 55 Start Capacitor 57 Battery Test Procedure 61 10 reasons APU AGM Batteries are not charged 63 Driver system Orientation 65 Driver Orientation ReeferLink 67 8second 5 minute delay circuit timer 69 Compressor Tecumseh 71 120VAC Service Procedures Idle Free Reference Sheets System Components Trouble shooting Table of Contents This Page Intentionally Blank Battery Separator RF101 Component Description amp Application Battery Separator IFS Part 35004 Component Location APU exterior Top Level front Above outside battery Description amp Application The Battery Separator is u
54. means that ta GFCI is functioning properly and is measuring a current imbalance A small leakage current is common and considered acceptable in many electronics from capacitive or inductive coupling and transient voltage surge suppressers When added together leakage from several different devices may exceed the 5 mA threshold If nuisance tripping occurs remove all devices from the Idle Free circuit and add them back one by one until the fault occurs The device tripping the GFCI has not necessarily failed but may not have been designed for GFCI use If the GFCI nuisance trips when only connected to the Idle Free system a ground fault may exist and requires attention 30 UBB RF110 Under Bed Box Explained Shore Power Plug Ground center neutral and hot 120VAC 10 AMP 120 VAC outside terminals power outlet Evaporator Ground center neutral and hot 120VAC outside terminals on when thermostat is in cool mode or thermostat fan switch turned ON UBB to APU Ground 2 from right neutral and hot 120VAC outside of ground terminal far terminal is heater on signal Blue 18 gauge wire 120 VAC on when thermostat calls for COOL OEM Fan Harness Top Terminals 12 GA 30 AMP Middle Terminals 14 GA 20 AMP Bottom Terminals 18 GA 10 AMP Thermostat 4 WIRE RED 12VDC o O to Thermostat OEM HVAC GREEN Evaporator Relay 12VDC E from Thermostat A O YELLOW Compres
55. n HEAT Mode The thermostat only turns on the Idle Free heater The driver controls the bunk s temperature using the Truck s Bunk controls heat intensity as well as fan speeds Air Conditioning 9 Slide the Idle Free Thermostat s Mode switch to COOL 10 Adjust the Idle Free temperature setting to its lowest point 68 degrees Note the temperature set point is displayed is in the lower right corner of the thermostat display window The minimum temperature setting is 68 degrees The closet located Idle Free evaporator fan should come on as soon as the set point is below the current room temperature by at least 2 degrees The compressor exterior located will start 8 seconds after the evaporator fan closet begins to operate 63 efre Refice Save rem Date Gree Ta Gremi Cat Gree Ignition Cut Out Circuit The Ignition Cut Out Circuit prevents Idle Free system operation whenever the truck s engine is operating and or when the truck s ignition Key is in the ON position 11 Ensure that the Truck s ignition key is in the OFF position 12 Locate the Idle Free Thermostat and slide the Fan switch to the ON position The fan should instantly begin to operate 13 Go to the trucks Ignition Key and turn the Key to ON without starting the truck s engine The Idle Free evaporator fan should cease operation 14 Turn the truck s ignition Key to the ACCESSORY position The Idle Free evaporator fan should begin o
56. ncludes the fan harness installation instructions and fuse placement instructions Overview The DC Fuse Holder may contain up to 4 fuses The top fuse is used in all applications see above paragraph Fuse 2 is used in all heater applications and contains a 30 AMP fuse used to provide power for the Bunk Blower fan This fuse supplies fan power whenever the Idle Free Heater is activated by turning the Thermostat Mode switch to Heat RF103 Fuses 2 3 amp 4 positions from top are connected to the bottom row of the Heat Relay Fuse 2 uses a 12 Gauge wire Fuse 3 uses a 14 gauge wire Fuse 4 uses an 18 gauge wire History The DC Fuse Holder can be fused incorrectly during installation Fuse placement instructions are included with every heater harness installation Kit Heat Relay see RF 106 Fuse 4 eee 10AMP Pune 18 Gauge Lt Blue 12 Gauge Pink Fuse 3 20AMP 14 Gauge Yellow 25 DC Fuse Holder RF108 DC Fuse Holder UBB This Page Intentionally Blank ReeferLink Connection RF109 ReeferLink Explanation ReeferLink Connection Component Location APU amp Reefer Unit Description amp Application The Idle Free ReeferLink Technology is patented and should not be used to power other battery based APUs The Reefer Unit must have an alternator rating of 65 AMPS or greater The Idle Free ReeferLink connection Kit should be used to supplement the Idle Free APU system The ReeferLink Connection Ki
57. of the contacts when contaminated potentially can leak Issues History The Drier has no history of issues and does not require Service 53 Drier Pressure Switch RF120 Drier amp Pressure Switch This Page Intentionally Blank Start Capacitor RF122 Air conditioner Start Capacitor Start Capacitor IFS Part 34005 Component Location Truck Exterior APU Top Level left side of compressor Description Application The Start Capacitor is used to assist in starting the compressor during hot or heavy use conditions The start capacitor engages when the inverter voltage drops to 100VAC The start capacitor raises the compressor start voltage to potentially 170VAC Overview The Start Capacitor uses a circuit board to control mechanical contacts The circuit board is attached to the capacitor with female push on terminals The circuit board controls a timer that sends the stored capacity during compressor start up over a 2 second period whenever the inverter voltage drops to lt 100VAC The Start Capacitor has 2 wires exiting the side of the removable black plastic cover Both of the start capacitor wires connect to the Run Capacitor located above the start capacitor see figure 2 Common Issues The Start Capacitor s contacts sometimes close and remain closed when they are supposed to be in an open condition This causes the inverter to overload and shut down Turning the inverter OFF then ON resets
58. on device such as a breaker or a fuse A GFCI does NOT protect against circuit overloads LOAD NEUTRAL SHORTS OR ungrounded shocks A tripped GFCI does not imply a circuit overload or failure Why Use a GFI The Idle Free system has been equipped with a GFCI to help protect drivers service technicians and equipment from shock hazards While no form of protection is 100 foolproof a GFCI adds a level of safety in an application where ground faults are preventable from corrosion and vibration How to Reset a Tripped GFCI The Idle Free GFCI can be reset by pressing the RESET button on the face of the receptacle An audible click will be heard and the green indication LED will illuminate if the GFCI has been reset successfully The GFCI requires power to actively reset it If the inverter is in the factory programmed power save mode the GFCI will not have sufficient power to reset Turn the inverter OFF by moving the rocker switch to the center position Then turn the inverter back on by moving the switch to the upper position The inverter will remain on for the next 6 seconds until resuming power save mode It is during this 6 second window that the GFCI must be reset The GFCI self tests upon every reset if the GFCI refuses to reset properly it is possibly failing GFCI Nuisance Tripping Often times a GFCI will repetitively trip without having a hazardous ground fault This is referred to as nuisance tripping Nuisance tripping is typically
59. oose the Idle Free inverter s GFCI may trip or the Inverter may overload shutdown A poor dirty or weak DC connection will prevent the Idle Free batteries from charging and will limit the energy available for adequate air conditioner starting An overloaded inverter shown with a red status light face of the inverter may be caused by a loose or dirty DC Cable A loose DC Connection will reduce the available energy needed to start the air conditioner The Idle Free Inverter s GFCI outlet may trip due to dirty connections leaking voltage back to the inverter Service APU DC Connections es Service Needs Riets Clean tighten and Protect all DC APU Frame 4 APU connection points APU Connection Points 1 Battery to battery Cables 6 2 Bulkhead Connectors 4 3 Battery Separator 2 4 Fuse 2 DC Input Connection Points IFS under bed Box UBB Truck Battery Box 1 Fuse 2 p Panal Mounts located on the rear s 2 Battery Connection side of the APU 3 Battery Connection 20 Tools needed e 9 16 wrench or socket e 2 wrench or socket e Side Cutters Parts needed e Tie straps 8 inch narrow e Battery Protection Connection Spray Procedure Overview Remove cover from APU examine all DC cable connection points Ensure that mens all are clean tight and treated for Sg ee corrosion protection Use a flashlight to check the Battery post connections that are located under if the upper lev
60. or Circuit amp Heat Circuit The Relays use a 12VDC coil The Heat Relay is a single pole triple throw relay SPTT The Compressor Relay the Evaporator Relay and the Ignition Relay are single pole single throw relays SPST The Ignition Relay controls 12VDC 2 AMP fuse power used to power the Thermostat The Ignition Relay is wired to use the normally closed contacts within the relay When the truck s ignition is turned on 12VDC power is sent to the Ignition Relay and the normally closed contacts are opened Opening the Ignition Relay circuit truck ignition ON disables the Thermostat functions Heat and Air conditioning RF103 The Evaporator Relay controls 120VAC power that is used to run the evaporator blower fan The Evaporator Relay is wired to use the normally open contacts within the relay When the thermostat is set to turn on the evaporator fan the 12 VDC coil is activated and the 120VAC is sent through the relay to the evaporator fan The Compressor relay controls 120VAC power that is used to run the compressor circuit The Compressor Relay is wired to use the normally open contacts within the relay When the thermostat is set to turn on the compressor circuit the 12 VDC coil is activated and the 120VAC is sent through the relay to the APU exterior compressor circuit RF112 The Heat relay controls 12DC power that is used to run the Truck s Blower Fan circuit The Truck s Blower fan circuit is switched to Idle Free b
61. peration The Evaporator Fan should run with the key in the OFF position as well as the ACCESORY position 64 Driver Orientation RF126 Reefer Link Connection The ReeferLink connection needs to be used connected before the Idle Free system is turned on This ensures that the Idle Free batteries remained charged during system operation The Reefer Unit must have an alternator rating of 65 AMPS or greater DO NOT run the APU batteries down and then connect to the reefer unit This will not harm the reefer but may result in the Idle Free batteries not being charged short run time DO NOT have the reefer link connector connected while you are driving unless you have a failed alternator on the truck or trailer Connecting if both alternators are working will not allow you to know if one of the alternators has failed because the opposite alternator will run both 12VDC systems The Idle Free Reefer Link system is a controlled DC connection between the truck and the reefer unit The ReeferLink connection provides battery charging for the Idle Free APU The Reefer Link connection allows the truck or the reefer unit to supply power to each other Inthe event that a truck alternator or a reefer alternator fail the ReeferLink connection is used to literally connect the 12VDC connections truck and reefer trailer together Using the Idle Free ReeferLink Connection 1 Make sure that the Reefer Unit is turned ON AU
62. re tight secure on the connection points under the plastic cover compressor top mm EZ EZ EZ EZ EZ EE EO OOOO M 69 Compressor A C RF129 A C Compressor Tecumseh Compressor Troubleshooting The Compressor requires the following operate 1 Se Oe Se Rbk sp WN FP O Inverter ON or Stand By Mode UBB Power Plug into the Inverter Outlet GFCI Outlet not tripped Ignition Key in OFF or accessory position 12VDC Power leaving the Ignition Relay RF107 RF106 Thermostat on COOL not in 5 minute shut down MODE RF103 12VDC Coil power at Compressor Relay RF106 120VAC power leaving the Compressor Relay RF106 120VAC power at the Compressor connection rear of the UBB RF110 120VAC power on the Pressure switch both terminals APU Receiver Drier Top 120VAC Power on the compressor top thermo overload switch RF120 Run Capacitor must have 5 wires connected to it RF122 Start Capacitor must have its 2 wires connected to the Run Capacitor RF122 R BLUE from run capacitor S RED from run capacitor C BLACK from pressure switch Run Capacitor Top Black Wire Blue Wire Red Wire 70 120 Volt Connections APU p N icto Service Procedures ief ee _ A nF RF130 120VAC Connection Service The Idle Free air conditioning 120 Volt Harness requires service to ensure proper system operation and performance When the Idle Free APU connections are dirty or loose the Idle F
63. ree inverter s GFCI may trip or the Inverter may overload amp shutdown An overloaded inverter shown with a red status light face of the inverter may be caused by the start capacitor not engaging needed to start the compressor because the start capacitor connectors are dirty or loose The Idle Free Inverter s GFCI outlet may trip due to dirty connections leaking voltage back to the inverter Service APU 120 Volt Air Conditioner Harness Connections Service Needs Clean tighten and Protect all 120 volt APU connection terminals Connection Terminals 13 total 1 Harness input White to Blue Neutral 2 Harness Input Pressure Switch drier 2 connections 1 2 EER OR Black Hot 4 Py P q 3 Run Capacitor 5 connections 4 Compressor Top 4 connections Male Terminal Connects to 1FS APU Hames Tools needed F 4 e Needle Nosed Pliers e Side Cutters 4 J Parts needed e Tie straps 8 inch narrow Procedure Overview 1 The Ties straps currently securing the 120 volt APU air conditioning harness need to be removed to Run Capacitar h allow all connections to be serviced 2 All connections need to be removed cleaned and tightened so as to ensure a tight fit onto the appropriate connection point 3 All connections cleaned amp properly tightened need to be treated with an appropriate preventative terminal protection spray Battery Corrosion Preventative Original Red Formula a en
64. s done in the truck s battery bank ensure that all cables are properly connected to the battery posts 8 APU Battery connections in the trucks battery bank are a Connected at the wrong connection point b APU ground cable is connected to a truck starter battery that has a fusible link between the alternator ground and the truck starter battery Volvo or Mack c APU truck battery connection points are separated onto different battery pairs Peterbilt uses 2 sets of 2 batteries in the truck s start battery bank One of these pairs is used to start the truck and the second pair provides non starter circuit DC power needs 9 The APU Battery truck battery connection points are stacked onto insulated OEM battery to battery cable lugs a Kenworth at times will use battery to battery cables that include plastic coverings that encase the battery lugs The plastic on these lugs needs to be removed when an APU Battery cable is to be sharing the same battery terminal Failure to remove this material will aide in preventing the AGM batteries from becoming fully charged 10 Battery cables are loose a All DC battery connections points need to be tight A loose battery connection is no battery connection b Loose battery connections prevent batteries from charging resulting in batteries with no capacity 62 lle froe Ar Dram Dray Gree 125 Driver Orientation idlefree Shore Power 1 Locate the Idle Free Voltmeter and
65. s in place to determine why it is or is not working The Top indicator light is the Input DC voltage The Bottom indicator light is green or flashing green when the inverter is ON or in stand by mode The Center Indicator light is only lit when an inverter load is present Green Okay Red too High The GFCI has its own indicator light that replicates the bottom light Status Green or Flashing Green If the bottom light is RED the GFCI indicator light will not be lit because the inverter is shut down when the status light is RED The inverter is fused internally with non replaceable fuses The inverter fuse power from the AGM battery bank is located in the APU exterior frame mounted unit above the battery separator The inverter can be used as a diagnostic tool e The top light for battery voltage level input e The Center light as a load light green Okay Red too High e Bottom Light why the inverter shut down Red Light Over load Flashing Red Battery voltage too low e Bottom Light gives current state of the inverter Green OKAY Flashing Green Stand By Relay Group RF106 Power Relays explanation Relay Group Component Location Truck Interior Bunk Area UBB upper level UBB REF Sheet RF110 Description amp Application The Relay Group is made up of 4 Ice Cube Relays The Relays are mounted on a DIN Rail in the upper portion of the UBB The Relays are used to power the Thermostat Evaporator Fan Compress
66. sed to separate the Truck s battery bank from the Idle Free AGM battery bank The Battery Separator is rated at 200 DC Amps and is controlled by its attached circuit board The battery separator connects the truck battery bank to the APU battery bank when it determines that the truck s battery bank has reached and exceeded 13 2 VDC When the battery separator closes the truck s alternator charges the combined battery banks the truck starter batteries and the Idle Free Batteries If the alternator fails to keep the combined battery voltage above 12 8 VDC the battery separator will open separate the battery banks The Battery Separator will combine both battery banks together when either battery bank reaches and exceeds 13 2 VDC The Idle Free AC to DC Power Converter RF104 is connected to the AGM battery side of the battery separator via the UBB under bed box RF110 This means whenever the Idle Free AC to DC Power Converter is plugged into Shore Power the ac to dc power inverter supplies DC Power to the AGM batteries When the DC power from the AC to DC Power converter raises and exceeds 13 2 VDC on the Idle Free battery bank the battery separator will close amp send the AC to DC power to the trucks battery bank via the battery separator If the combined battery bank voltage drops below 12 8VDC the battery separator will open the connection between the 2 battery banks Common Issues The Battery Separator is trouble free The
67. sor Relay MM Rermostat 12VDC from Thermostat to Timer Delay Relay Caution Blue Heater Relay 12VDC from Ensure 250A APU fuse is removed before servicing high amp de connections Thermostat UBBtOAPU af afk ignition Volt of Volt Meter on when 2 AMP fuse is in holder Ignition single grey wire from truck ignition source fused input from source Positive amp 250 AMP Fused power from AGM AN batteries trough RED DC connector on rear side of APU IFS 32043 Ground Cable from AGM battery Power through Black DC Connector on rear side of APU IFS 32045 31 UBB RF110 Under Bed Box Explained This Page Intentionally Blank Evaporator Module RF111 Evaporator Module Evaporator Module IFS 91301 Component Location Truck Interior Bunk Area Located in the closet on the closet on a bunk side wall Description amp Application The Evaporator Module contains an evaporator coil an electric blower fan and an expansion valve The Evaporator s blower fan is a single speed 120VAC fan controlled by the Thermostat switch settings RF103 and the Relay Group RF106 The Evaporator coil and expansion valve control 134A refrigerant The Evaporator Module has 2 refrigerant hoses a drain hose and a power cord exiting out the bottom of the module The refrigerant and drain hoses leave the bunk area through a 2 hole drilled into the b
68. stat aR a DIP Switch Settings 2 E o o Wiring Terminations Room Temperature Displays the current room temperature E Reset Button Resets thermostat back to factory defaults ore Low Battery Indicator Indicates when the batteries need to tad 12VDCIN from be replaced p 4 System Switch Selects system preference Quick Reference iaa Instructions ccccccncnnonenos Stored in slot at top of thermostat dica ee BS Fan Indicator Indicates when the system fan is running i System Status Indicator Displays information about the status of A S the system Green wire Evaporator ON EB Arrow Buttons Used to increase or decrease settings Not Used EJ Set Temperature Displays the current set point temperature Not Used Fan Switch Selects the system fan mode Battery Compartment Located in the back of the thermostat BLACK BLUE BLUE Power Converter RF104 Shore Power Description Power Converter 120VAC to 12VDC Shore Power IFS Part 35003 POSITIVE TERMINAL LUG RED DLS SERIES M Component Location UBB Under Bed Module Upper level Description and Application The Idle Free Power Converter converts incoming 120VAC power Shore Power to 12VDC power When Shore Power is available the converter maintains the Idle Free AGM battery volta
69. t consists of 4 parts 1 APU DC Connection cables internal and panel mount receptacles fused 2 Truck connection connector body amp cover 3 Trailer connection connector body amp cover fused 4 Truck to Trailer interconnects Cable set The ReeferLink Connection provides the 12VDC power available when the Reefer unit is running to be used to maintain the Idle Free APU battery bank voltage and the trucks 12VDC Battery voltage levels Refrigerated Trailers include electrical systems that start the reefer unit when contents of the trailer require temperature management Refrigeration units will start their engines when the starter battery requires charging A starter battery voltage of lt 12 1VDC will engage the start circuit of the reefer unit If the Idle Free ReeferLink connection is in place the reefer unit will engage its start circuit whenever the reefer s battery and the Idle Free battery bank drop to lt 12 1VDC The reefer unit will continue to operate until the alternator output amperage drops to lt 8 AMPS When the reefer unit is running with the Idle Free ReeferLink connection in place the following will take place 1 Reefer Battery and Idle Free Battery bank will see alternator output voltage and amperage 2 Reefer Output Amperage will be based on a APU Mode air conditioning or Heat b Battery voltage level of Idle Free battery bank Reefer starter battery truck starter battery bank 3 Reefer Alternator will close the Id
70. t has 2 battery cables connected to it Remove the single cable from the far post first clean the cable end and the battery separator post Replace cleaned cable end to the far post and tighten securely Repeat the procedure 3 on the closest battery separator post 2 cables Treat the cleaned and tightened battery separator posts with Battery Corrosion protection spray Remove the rubber fuse cover and remove the fuse Clean the fuse ends fuse receiver terminals amp the cables ends that connect to the fuse Return the fuse to the fuse holder and tighten to ensure no cable movement Treat the cleaned and tightened fuse posts with Battery Corrosion protection spray 44 DC Cam Lock Connectors RF117 Current DC Voltage Level of IFS AGM Battery Bank Cam Lock Connectors Component Location APU Exterior DC Connection Points Part s Red Plug 33017 Red Socket 33014 Black Plug 33018 Black Socket 33015 Green Plug 33016 Green Socket 33013 Description amp Application The DC Cam Lock Connectors are connection points between the APU Truck s battery bank amp the UBB Cam Locks are used so the critical DC connections are controlled by Idle Free manufacturing enabling testing of completed units Overview The DC Cam Locks form a sealed DC connection point between the truck s battery box the APU and the UBB The Cam lock connectors use a locking cam male connector that locks into the female panel mount
71. to 2 halves top and bottom The bottom half represents the battery voltage when the truck s engine is not running The top half of the voltmeter displays the voltage when the truck s engine is running or when the truck is plugged into Shore Power If the truck s engine is running a least one of the top 3 lights should be lit The longer the truck engine runs the more lights will be lit The voltage reading of this volt meter should be the same as the trucks battery voltage when the truck s engine is running If the battery voltage on the truck s dash is higher than the voltage reading on this voltmeter gt 5 Volts trouble shoot the DC Connections Service Procedures IFS 63004 Common Issues The Voltmeter has no history of issues Service The voltmeter does not require any service DC Voltage Display RF102 Current DC Vo sia Level pi ttery Bank This Page Intentionally Blank Thermostat RF103 Thermostat Description Thermostat IFS Part H 37012 Component Location Bunk above Bed Side wall or closet Description and Application The Idle Free Thermostat contains a LCD display and two Slide Switches The IFS Thermostat uses two AA Batteries to power the display and to send switch signals to the Idle Free Relay Group RF106 The left slide switch is used to turn on the air conditioner or turn on the heat The center position of the left slide switch turns the system OFF The right slide switch has
72. ure that fuel is present If the tank fuel pick up tube is not properly located in the fuel tank or if the truck was run out of fuel the fuel filter may be void of fuel The fuel filter will need to be primed if the fuel filter does not have fuel present The Water Heater Module will shut down if the Water Heater over heats Overheating will take place if the coolant circuit has its coolant supply cut off closed valves If the Water heater shuts down 5 times the heater will not attempt to re start unless the 12VDC power plug is removed and re installed into the socket Heater reset procedure 39 Water Heater Module RF114 Water Heater Module Explanation Service The Water Heater Module requires a fuel filter replacement at the beginning of each winter season Part 42002 The water heater exhaust needs to be checked for restrictions and obstructions The water heater combustion air intake needs to be checked for restrictions and obstructions Top of Water Heater Oval connector is Power connector left 40 AGM RF116 AGM Battery Bank explained AGM Batteries IFS Part 35001 Component Location 1 APU Exterior Lower Level or 2 BTF Battery Box Description amp Application The Idle Free system uses 4 AGM batteries connected in series The Battery Family is Group 31 and each battery contains 105 AMPS useable The 4 AGM batteries are connected together with Red Cables and Black The Posit
73. ut circuit at the ignition key The Mack Ignition cut out circuit begins at the dash panel passenger side top The Kenworth Ignition circuit begins in the fuse panel on the floor behind the brake pedal ki Do not use the truck s ignition to turn off the air conditioner Always use the Thermostat Mode Switch to control Air conditioning and Heat functions 23 Ignition Cut Out Circuit RF107 Ignition Cut out circuit explained This Page Intentionally Blank DC Fuse Holder RF108 DC Fuse Holder UBB DC Fuse Holder IFS Part 36003 Component Location Truck Interior Bunk Area Connected to the inside top level of the UBB RF110 Description amp Application The DC Fuse Holder contains 4 openings for fuses The top fuse is always a 2 AMP fuse that powers the Volt Meter RF102 and the Thermostat RF103 The 2 fuse from the top powers the bunk Blower fan when the Idle Free water heater is a part of the system This fuse is a 30 AMP fuse For Mack and KW trucks the remaining fuse positions are not used The 3 amp 4 fuses from the top are only used in some truck specific applications where bunk heater control is a part of more than one circuit International Freightliner amp Volvo require fuses place in positions 3 amp 4 When an Idle Free Heater is a part of the system truck specific instructions are included along with the OEM fan harness Kit IFS Part 91801 Kit 91801 i
74. wer Circuit 3 Condenser Fan Relay 4 Condenser Fan Water Heater amp Condenser Fan Relay Fuse Holder Overview 12VDC Idle Free Battery power feeds a 2 place fuse holder located near the battery separator in the upper level of the APU exterior The fuse holder contains 2 fuses 20 AMP fuse for the Water Heater and a 15 AMP fuse for the Condenser Fan The Water Heater fuse feeds 12VDC power to the Water Heater power plug located on the top of the Water Heater oval plug The Condenser Fan fuse feeds 12 VDC power to the Condenser Fan Relay located above the Drier on the aluminum wall in the top level of the APU exterior The 12VDC power from the Condenser Fan Fuse is sent to the Condenser Fan when the 120VAC Compressor circuit is energized RF 112 The Condenser Fan Relay has a 120VAC coil B z 7 Common Issues History The DC Wiring APU has no history of issues The condenser fan circuit must be fused with a 15 AMP Fuse a 10 AMP fuse will not support the start needs of the Condenser Fan Service The APU DC Circuit requires basic service to ensure that the fuse terminals the relay terminals and the Power connectors are clean and tight Make sure that the connector gasket on the water heater top Power connector is in place green in color Note the Water Heater Power plug connector into the top of the water Heater can be used to reset the water heater in the event that the Water Heater has stored
75. y of the other relays to receive 12VDC power The evaporator relay and the compressor relay pass through 120VAC when activated by the thermostat The inverter must be turned on with a green or flashing green light located on the GFCI outlet RF105 To check each relay for coil activation place your volt meter on DC and place probes into the relay coil terminals page 13 Use the ground for the relay being checked The relay 12VDC wires are from the thermostat or the ignition source colors for 12VDC coil operation are e Grey Ignition Relay e Green Evaporator Relay e Yellow Compressor Timer amp compresor Relay e Blue Heat Relay triple relay Relay coils are activated with 12 VDC from thermostat switches Thermostat switch position determine 12VDC to relays Ignition relay passes through fused 12VDC power when truck ignition is turned OFF Evaporator relay passes through 120VAC when thermostat is in COOL mode or Fan switch is in ON mode Compressor Relay passes through 120VAC when thermostat is in COOL mode and temperature setting is calling for COOL Compressor Relay is delayed 8 seconds using a Timer relay Heat Relay passes through 12VDC when thermostat is in heat mode Not all heat circuits are used for all trucks Fuse panel fuses all 3 heat circuits RF108 20 Relay Group RF106 Power Relays explanation Timer for the compressor circuit The Compressor Circuit includes a timer that delays the start of the compressor
76. y terminal If the battery connection looks clean check the battery nut to make sure that the battery cable does not move Bulkhead Connectors 1 Remove the rear cover of the APU to reveal the DC Bulkhead connectors located on the rear side of the APU Disconnect all exterior rubber connectors by twisting them counter clockwise and pulling them out 2 Inspect the panel mount connection points to ensure cleanliness amp no signs of corrosion Repeat this procedure with the male plug in connectors 3 The Black bulkhead connector is ground the Green is truck battery bank fused power and the red connector feeds the Under bed module with fused DC power for the Idle Free inverter and other DC needs 4 Use Dielectric Grease into the bulk head connectors prior to re connecting the color matched male connectors into the bulk head connectors 5 The bulkhead connectors will only allow the male plug to go in if the proper alignment is achieved Place a negative twist counter clockwise unto the cable connector prior to inserting it to ensure that the connector remains tight Twist each connector clockwise to lock them in place 43 AGM RF116 AGM Battery Bank explained Thermostat must be in the OFF position Battery Separator T Inspect both terminals on top of the battery separator for cleanliness tightness and protection treatment The far post on top of the battery separator has a single cable and the closest pos
Download Pdf Manuals
Related Search
Related Contents
friggitrice elettrica biela14 gen ii serie lov™ capitolo 1 Biostar PT880 Owner's Manual Makita 41900 User's Manual BIAevaluation (Biacore J) 取扱説明書 for Texas - American Home Inspectors Training Institute G90 GSM & MMS ALARM 品名 ティ二 mcpa sodium 300 herbicide commercial attention poison lire l ASUS P751JA User's Manual Copyright © All rights reserved.