1. 1 SMS to main unit phone number Confirmation user will receive a SMS for confirmation as N 111111 M To Program Receiver s Phone Number Send 000000M 0932345678 0935111111 SMS to main unit phone number Confirmation user will receive a SMS for confirmation as M 0932345678 0935111111 to indicate programming is successful Send 000000M SMS to main unit phone number Confirmation user will receive a SMS for confirmation as M deleted E To Program Email Address Send 000000Ejuly yahoo com peter hotmail com SMS to main unit phone number Confirmation user will receive a SMS for confirmation as E july yahoo com peter hotmail com to indicate programming is successful Send 000000E SMS to main unit phone number users will receive a SMS for confirmation as E deleted To Activate Release the System Send 000000A1 SMS to main unit phone number Confirmation user will receive a SMS for confirmation as detector on to indicate programming is successful Send 000000A0 SMS to console phone number Confirmation user will receive a SMS for confirmation as detector off To check the pictures by sending SMS Password m n The main unit will send mms to user s mobile phone and E mail M refers to one of video input There are 4 in total and it is from 1 to 4 N refers to 1 7 pictures Ex Sending 00000011 to the SIM card number in the system User s will receive 1 picture taken by video 1
2. Quick programming Installation 1 Insert SIM card which MMS is activated without PIN code 2 Plug in power 12V and turn on It sounds 2 beeps and 1 beep around 20 seconds later to indicate system is ready If 2 beeps not heard remove the power check re insert the SIM and re power after 3 minutes 3 You can ask your operator for correct mms setting 4 Follow the examples to program system Send sms 000000M 090012345 090123455 peter yahoo com to the SIM card number in G90 Key in 000000 M 0932345678 0935111111 0930333333 Epeter hotmail com Send this short message to console phone number Confirmation administrator will receive a SMS for confirmation as M 0932345678 0935111111 0930333333 Epeter hotmail com to indicate programming is successful 0932345678 represents this is the administrator phone number 09351111111 and 0930333333 are general user Note Administrator does not need password to program and operate the system password is necessary for other user s to perform the work Commands 1 The commands in the table to operate the system N Program password M Program receiver phone number E Program receiver email address A1 A0 Arm Disarm D Check System Settings 6 T Listen in lt m gt lt n gt SMS to check images 8 C Default settings 9 U Accessoriesalarmm o 2 Setting examples N To Program Password default password 000000 Send 000000N11111
3. is within 140 bytes In Chinese within 70 words including figure letter and other signs or it will make settings false 3 It doesn t matter whether the letter in the SMS command is capital or not 4 Password is 6 digits from 0 9 5 Receivers for phone are 6 and 3 for E mail at most 6 When program several phone numbers and E mail at the same time there must be a space or or between them Make sure that all these be input in English 7 User can set several functions at the same time and also can set the system one by one 8 The E mail address must be English letters digits or underline With an interval sign can program others after the mail address The users can set at most 3 mail box The new mailbox will replace the former mail programmed before If you program more than one mailbox programming them at the same time 3 2 MMS Access Method 1 Follow the below stated sms format in order to make the system work in different countries 2 Short message form Password g Homepage PORT IP address APN IP Port User Name Password Be careful that Content in bracket is default number it is ignorable if not have The can not be ignored eg The Establish content of short message for New World of HONG KANG 000000ghittp mmsc nwmobility com 8002 192 168 111 1 mms 9201 The short massage content reference to parameters provided by telecommunic ation company The parameters maybe differe
4. lment If you are not able to operate the remote control unit s normally after System resetting or adding new one s you need to re enroll the remote control unit s to system Instruction is shown as follows 1 Connect the input Power to the system 2 After two beeps press any button within 15 seconds You will hear one beep to indicate that it is successful It can match 10 controls at most 3 If the remote control lost or you want to one of them to be disabled You can reset the controllers Sending sms password C to the system and follow the ways of 2 4 Note We suggest that the users disarm the system when the system is off Because if it is armed the system will detect the users and alarm immediately when power on the alarm 2 3 Extension units operations You can install 9 extension units within 100 meters ofthe main unit The extension units can be wireless smoke detectors and wireless door window sensor It will send sms to the user when it alarms The users should match the extension units to the main unit first After power on the main unit and heard two beeps power on the wireless detectors and trigger it within 15 seconds A beep from the main unit indicates that it matches successfully 3 Important notice 3 1 SMS setting 1 Administrator does not need password to program and operate the system while password is necessary for other user s to perform 2 When the SMS content edited in English it
5. lt will display the information in the mms D To Check System Settings Send 000000D SMS to main unit phone number Confirmation user will receive a SMS for confirmation of what you have programmed T To listen in need to connect one Mic Send 000000T phone number SMS to main unit phone number In 1 minute system will call the phone number and the users can listen in the premise If you just send 000000T the system will call the phone which sends the sms Products introduction 1 1 Introduction This system is a brand new Hi Tech product in the wireless communication era it has integrated mobile transmission technology and IR image monitoring and thermo detection such kinds of security technologies It has breaking thru the limitation of conventional CCTV system that transmitting by hardwire cable modem which is difficult to install and has higher cost and limited by the installation environment it also has problem of easy to be invaded This product combines the future mobile user s needs to let any mobile phone user must have GPRS MMS SMS function can use their mobile phone and mailbox function to back up the image information to avoid the destroy of evidences can real time receives the alarm messages from any remote location by the devices or monitoring the real time voice and image from the site for immediate identification It meets various demands from sectors of household office factory stores e
6. minutes when it detects the intruders 2 1 3Listen in Need to connect a Mic You just need to send the SMS to the console and you will receive call back for the receiver to listen in the sound of premise You can send SMS T telephone number or mobile phone number in one minute console will phone the number behind of the T Users answer it and they can monitor the voice of the scene Send SMS T console will call the mobile phone number which sends SMS 2 2 Remote control guide 2 2 1 Button instruction gt 2 Disarm 3 Test lt q Button 1 Arm You should operate the remote control unit within 100 meters transmission range to activation the system Once the button pressed the console will sound continuous two beeps and system enter armed mode after 1 minute Button 2 Disarm You should operate the remote control unit within 100 meters transmission range to release the system Once the button pressed the console will sound a long beep and system enter disarmed mode Button 3 Testing You should operate the remote control unit within 100 meters transmission range to release the system Once the button pressed the console will sound beep a twice and system enter disarmed mode If press and hold the button for 3 seconds system will enter or exit factory testing mode In testing mode the system will beep one time when receive the sms and will beep twice when send the mms 2 2 2 Enrol
7. nt in different country and different area it depend on the telecommunication company corresponding to the SIM card in it New World Operator New World Access Point APN mms Homepage http mmsc nwmobility com 8002 IP address 192 168 111 1 Login name Password IP Port 9201 3 Explain of the short message 1 000000 is the default password of host monitor 2 g is command character 3 http mmsc nwmobility com 8002 is the Homepage some times call the MMSC URL 8002 as the http port when the port is 80 it can be ignored 4 192 168 111 1 is IP address Gateway IP address 5 mms is APN APN is abbreviate of Access point name 6 If the port is 9201 it can be ignored but the followed can not be ignored So the short massage above can also be written as 000000ghittp mmsc nwmobility com 8002 192 168 111 1 mms 7 User Name and Password can be ignored if not have but the followed cannot be ignored 4 Port 4 1 Port O 315 ANTENNA LEDI z 1 2 8 LED2 SIM CARD PROWER O GSM ANTENNA CON2 Eunuuununnnunun e 1 2 16 VIDEOL VIDEO2 VIDEO3 VIDEO4 Power 12V power supply Center positive GSM Antenna Antenna Remote antenna SIM Card SIM socket ISP Program updating port Vide 01 Video 04 LED1 Power LED indicate light LED2 GSM netwo
8. number and it will hang up the call After taking a picture of the premise it will send the picture to the caller and the first email address if any email address has been programmed Note You can only check the main unit by calling If you want to check other cameras you need to send sms to check it If the user already sends sms to check different cameras the default checking route by sms will be changed Ex The you sent sms 00000021 to the main unit you will see one picture from video 2 2 By Sending SMS SMS content Password Video1 picture quantity EX sending 00000012 to the main unit SIM card number 000000 is the factory default password 1 stands for Video 1 2 stands for sending 2 pictures to the user s mobile phone and mail box Note If none phone number is programmed as alert receiver any mobile phone with feature of MMS activated can perform this function Only the administrator and user s can do so when receiver phone numbers are programmed while SMS plus password for other user s 2 1 2 Infrared Heat amp Motion Detection Infrared heat amp motion is active under system arming mode to detect any motion object in the premise If any motion object i e intruder is detected system will send 3 pictures to designated receiver The first mms is 1 picture and two in the second mms After sending pictures system calls receiver and it will call for 5 times if nobody answers the phone It will alarm again in 10
9. rk Light COM1 definition 1 2 Mic Input connection 3 4 Flash light driver connection 2 positive 3 negative Alarm light connection 5 6 Siren connection 5 positive 6 negative 7 8 Backup battery connection 7 positive 8 negative COM2 definition 1 12V power 9 12V Power 2 Negative CHA 19 Negative CH3 3 PIR input 1 PIR input 4 PIR input 12 PIR input 5 12V Power 13 12V Power 6 Negative aus 14 Negative He 7 PIR input 15 PIR input 8 PIR input 16 PIR input 4 2 Port parameter 4 2 1 Main parameter Power 12V DC 1A Backup battery 12V 3 5Aplumbic acid battery Standby current 40mA without including extension units Max work current 0 35A By average without including flash and siren Video signal requirements Input CVBS complex video signals support PAL NTSC IR requirements 12V DC Output form dry contact N C Smoke detector Voltage 12V DC Output form Dry contact N C Flash light Voltage 12V DC Siren Voltage 12V DC
10. tc 1 2 Features IR amp camera detecting the double detection technology can eliminate the false alarm caused by environmental reasons e Can connect one to four cameras Send pictures to your mobile phone or E mail when it alarms o Use mobile phone or computer to check the picture anytime wherever With IR night vision camera it provides full time 24 hours day and night monitoring function Remote listen in function o Send pictures and auto dial to inform the users when it alarms Remote control the system easy to operate 1 3 Products pictures vo mn 4 1 Remote control antenna 6 Power indicate light 2 GSM antenna 7 Power input 3 COM1 port 8 GSM Network indicate light 4 4 video input connection 9 COM2 port 5 SIM socket 1 4 Package List Standard packing 1 One Main unit 2 Two Antennas 3 One adaptor 4 Two remote controls 5 One user manual Optional 1 1 4 box cameras 2 PIR 3 Other sensors detectors 4 Remote control At most can match 10 pcs Please check all components in the package 1 5 Major Technical Parameters PIC Format JPEG Resolution 320x240 Remote Effective Range lt 100 m Working Temperature 0 50 C Relative Humidity 10 90 non condense 2 Operation 2 1 Major Function 2 1 1 Active reviewing function 1 By Calling Make sure the feature of MMS is activated for both caller and the main unit You just call the unit phone

Download Pdf Manuals

image

Related Search

Related Contents

Samsung VP-DX10 Инструкция по использованию  Mifare Configurable Sector Reader User`s Manual  La protection juridique des informations à caractère économique  Zotac ZBOX AD04  SCoT Mode d`Emploi 3 Comment aménager des espaces habités  WSRF2OWLS User Manual  DeLOCK USB 3.0 Adapter  め ー 50マイクロスイッチ付圧力計取扱説明書  Exhibitor Service Manual  Cisco Systems 4500 E-Series Switch User Manual  