Home

Cleanus Bum Wash User Manual

image

Contents

1. 1 Lever Replacement 2 Nozzle Replacement Remove the lever along the axis as shown in the Pull out the tube gently and don t release Remove figure Install a new lever by pushing it in You should the old nozzle along the axis as shown Insert a hear a click sound new nozzle 3 10 Tie Fg Nozzle ag A Regulator Replacement 4 Leakage Rotate the lever to working position wash or bidet If water leaks from the two ends of the water hose Pull out regulator from the inlet pipe using pliers re tighten the nuts Do not over tighten Push the new regulator into the inlet pipe Rotate the lever to non working position off Troubleshooting amp Specifications Troubleshooting Turn lever to maximum flow Low water pressure of the unit Remove regulator cap and O ring Refer to manual for instructions Low water pressure of water supply Contact local water department Water flow is low while using Water shut off valve is closed Open shut off valve Filter of T shaped connector is clogged clean the filter Filter of water inlet hose is clogged clean the filter Nozzle head is stuck Clean the nozzle head External water pressure is low Increase external water pressure The maximum water pressure of the unit is 115 PSI 0 8 Water is dripping while using External water pressure is too big Mpa If water pressure is higher please contact local water department Do
2. bolts into expanding nuts Be sure to keep the side with FRONT up Installation Bracket template Installation template Wing nuts are used for Installation Method B 5 Remove the installation template 6 Slide product onto toilet as shown in the figure Installation template Installation Method B 1 Refer to steps 1 and 3 of Installation Method A Do not install expanding nuts 2 Refer to step 4 of Installation Method A but secure panel with wing nuts instead of expanding nuts 3 Refer to steps5 and 6 of Installation Method A to complete installation Connecting the water hose 1 Close the shut off valve and detach the water hose from the toilet tank Connect the T shaped connector to the water tank Make sure the rubber uo washer is in place 2 Connect the water supply hose to the T shaped connector You may remove the water regulator cover and regulator O ring if the water pressure of the product is too low See figure 1 Remove the regulator component with pliers 2 Remove the regulator cover and regulator O ring but leave the remaining parts 3 Reinsert the remaining regulator component without the cover and O ring into the inlet pipe of seat You must use the regulator cover and O ring when the water pressure is greater than 15 PSI Q Regulator A SW lt Sealing O r Regulator O ring N Regulator i cover Xe 3 Connect the main body to the T shaped connecto
3. dd cleanus Toreguest service refer to the user s manual If failure or damage occurs after referring to the manual stop using and contact the retailer for service cleanus User Manual User Manual Contents Operation Cleaning and Removal Maintenance Troubleshooting amp Specifications Parts Product Water inlet Removal button Seat cover Water tank Lever Seat T shaped connector Bidet nozzle Wash nozzle Water supply hose Bowl Shut off valve Water inlet hose 03 Components 1 Main body 2 Installation Template RD D 3 Hardware LE Expanding Nuts 2 D Bracket Sliding plates 2 Wing Nuts 2 4 T shaped connector 5 Water hose 6 User Manual User Manual Filter C There are two installation methods You may use expanding nuts or wing nuts 04 Installation Please make sure you read the instructions carefully and install it properly 1 Insert the connecting bolts into sliding plates V b b 2 Insert the connecting bolts with sliding plates into the bracket A The water pressure range for this product is 10 115 PSI 0 07 0 8 MPa Caution 05 Installation Method A recommended 1 Loosen nuts and remove the old seat and seat lid 2 Insert expanding nuts into the toilet bowl holes Seat and seat lid 3 Place installation template onto toilet bowl 4 Place bracket onto toilet bowl and screw connecting
4. not disassemble or repair the unit Caution Specifications Static Pressure 10 115 psi 0 07 0 8MPa Water Pressure Range Dynamic Pressure above 5 psi 0 03 MPa Backflow Prevention Check valve vacuum breaker Weight 4 6 Ibs 2 09 kg 11
5. r 4 Open the shut off valve to check for leakage using the supplied water hose Make sure filter and rubber washers remain in water hose 7 Washer Filter 1 Do not lift the product with the seat cover and seat open You may damage the product 2 The water supply must be between 32 F and 105 F 0 F 40 C Caution 07 Operation Wash Turn the lever clockwise The wash nozzle will move forward and begin washing Bidet Turn the lever counterclockwise The bidet nozzle will move forward and start washing Off amp Self Cleaning Off Keep the lever vertical Self Cleaning Hold the lever at 25 for a few seconds CD Nozzles automatically clean themselves after each use 08 Low flow High flow il RSC yn Cleaning amp Removal 1 Cleaning the ouside of the product 2 Cleaning the nozzles Use a smooth sponge cloth with diluted kitchen Pull out the nozzles gently and use a smooth cloth detergent sponge or your friend s toothbrush with kitchen detergent to clean the nozzles Paint thinner Insecticide 3 Cleaning the filter and regulator 4 Removing the main body GE Do this if the flow is lower than usual Close the lid Push the removal button and pull out product as shown in the figure 1 Clean the filters on both sides 2 Clean the regulator O ring See page 10 to find out how to remove regulator Filter 09 Maintenance