Home
NESS – ECO8x User Manual
Contents
1. Ness acclaimed Digital Video Recorders store video footage on hard disk drives for fast and easy to retrieve tapeless recording Ness DVRs are available in 4 6 9 and 16 channel models to suit all applications and all budgets even mobile models for use in vehicles such as buses and trucks Most DVR models are Internet Ready for instant connection to a LAN and broadband internet connection for remote viewing Ness CCTV means Consistent Commitment To Value DI NESS ECO8x CONTROL PANEL USER S MANUAL MADE AUSTRALIA OPTIONAL RADIO ACCESSORIES Ask your installer about the range of Ness radio devices for the optional extra convenience of wireless remote control and wireless detection Operating your Ness security system can be as convenient as opening your car door The Ness Radio Key provides the benefits of separate ON OFF and PANIC buttons in a slim waterproof remote control Ness radio products require a Ness Radio Interface 100 200 to be fitted to the control panel RK4 Radio RK3 Radio Key Key RADIO KEYS Fully waterproof ultra slim 3 or 4 button Radio Keys for remote control of the control panel With separate buttons for ON Arm OFF Disarm PANIC and AUX functions RK4 only Including long life lithium battery RADIO KEY PENDANT Fully waterproof pendant style transmitter can be used as a portable wireless Panic button N U RK1 Radio Key Pendant Supplied with a neckc
2. by KEYPAD Press If the Memory SHortcut is enabled Or press RI User Cope The Exclude light will turn on Press The most recent event will be displayed Press Fhe next most recent event will be displayed Press and so on up to 30 events Press to exit Memory Mode The panel stores a comprehensive event memory including Arming Disarming Low Battery Mains Fail and Alarm events The memory is constantly upgraded and the last 30 events are always available for viewing This memory display can only be selected while the panel is in the Disarmed state TO CLEAR THE MEMORY LIGHT The MEMORY light flashes continuously when an alarm has occurred as a reminder to view the alarm memory The MEMORY light stops flashing after the memory is viewed as shown above The MEMORY light is automatically cleared next time the panel is Armed 16 NESS ECO8x CONTROL PANEL USER S MANUAL OPERATION When reviewing the event memory the keypad lights will show the stored events as shown on this table MEMORY MODE EVENTS INDICATED BY KEYPAD LIGHTS INDICATOR ON THE KEYPAD MEMORY EVENT ZONE LIGHTS 1 8 Zone alarm no lights Panel Disarmed ARMED Panel Armed or Area 1 Armed ARM2 Area 2 Armed MAINS Mains power failure BATTERY Low Battery TAMPER Tamper alarm Siren cover panel etc EXCLUDE Panic alarm LINE Telephone line fail RADIO EXC
3. Ness ECO8x ALARM CONTROL PANEL USER S MANUAL A 15 00 Revision 1 Quality Endorsed Company 1509001 Lee Ges NSW Head Ofte ony INEZ Security Products www ness COm au MADE W AUSTRALIA Lo a d v Australia s largest designer and manufacturer of high quality security products N55 NESS SECURITY PRODUCTS f Australian Communications Authority TELECOMMUNICATIONS COMPLIANCE WARNING Installation and maintenance shall be performed by qualified service personnel only CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions on the battery COPYRIGHT NOTICE Head Office Ness Security Products Pty Ltd ABN 28 069 984 372 4 167 Prospect Hwy Seven Hills NSW 2147 Australia Ph 61 2 8825 9222 Admin Fax 61 2 9838 8508 ness ness com au SYDNEY 4 167 Prospect Highway Seven Hills NSW 2147 Ph 02 8825 9222 Fax 02 9674 2520 sales ness com au MELBOURNE 24 Terracotta Drive Blackburn VIC 3130 Ph 03 9875 6400 Fax 03 9875 6422 nessmelb ness com au BRISBANE Unit 3 471 Lytton Road Morningside QLD 4170 Ph 07 3399 4910 Fax 07 3217 9711 nessbris ness com au PERTH Unit 1 567 Newcastle Street West Perth WA 6005 Ph 08 9328 2511 Fax 08 9227 7073 nessper ness com au ADELAIDE 13 Weaver Street Edwardstown SA 5039 Ph 08 8277 7255 Fax 08 8276 3028 adelaide ness com au ECO8x USER S MANUAL This revisio
4. Day Zone selection mode ZONE SELECTION Zone No To select or deselect zones to be Temporary Day Zones The selected zones are indicated by the corresponding zone number Permanent Day Zones installer option P53E are not displayed in selection mode Permanent Day Zones can be selected as Temporary Day Zones but this has no effect as those zones are already day zones EXIT SELECTION MODE Press to Saves changes and return to normal operating mode ENABLE DAY MODE Press LO to enable disable Day Mode When Day Mode is enabled any unsealed day zone will sound the programmed output for 2 seconds When Day Mode is disabled an unsealed day zone will simply be indicated on the keypad as an unsealed zone The HOME light flashes continuously when Day Mode is enabled Di NESS ECO8x CONTROL PANEL USER S MANUAL Programming your Ness ECO8x is a simple process using the keypad To enter program mode you need to know your Master Code which is user code number 1 see the table on the next page If you forget your Master Code it can be reset by your installer USER CODES The ECO8x panel has 15 user codes which can be operated by keypad code 3 6 digit PIN or by optional radio key To add change or delete a keypad code follow the steps on page 21 To add or delete radio keys ask your installer The panel is supplied with the Master Code pre programmed as 123 You should re program t
5. LUDE Radio Key Panic alarm RADIO BATTERY ZONE Radio Device battery low Device number is indicated by a zone light RADIO BATTERY ARM Radio Key battery low Radio Key number is NOT indicated RADIO TAMPER ZONE Radio Device tamper alarm Device number indicated by a zone light NESS ECO8x CONTROL PANEL USER S MANUAL 17 TEMPORARY DAY ZONES The Ness ECO8x control panel has a Temporary Day Zone feature which allows easy and flexible Day Zone selection and operation Temporary Day Zones operate in addition to Permanent Day Zones which are usually setup by the installer While remaining in normal operating mode the user can add and remove Temporary Day Zones As an extra feature the user can easily enable or disable Day Mode which includes both Temporary and Permanent Day Zones Day Zones can be programmed by your installer to beep the keypad or briefly sound the siren s or flash the strobe light TYPICAL APPLICATIONS Day Zones are useful for a variety of applications such as a shop door beeper triggered by a reed switch on the door For example in a shop you could enable Day Mode to alert you when a customer enters the front door You can also enable additional Temporary Day Zones to monitor switches on for example the rear door or the fridge doors COMMANDS Accessed from normal operating mode ENTER SELECTION MODE Press LEI followed by when in operating mode to enter Temporary
6. can then acknowledge the alarm by pressing the key on their telephone Press the la key for at least 2 seconds after the alarm beeps If the alarm is not acknowledged the LINE light on the keypad will flash continuously until the panel is next armed NESS ECO8x CONTROL PANEL USER S MANUAL 23 NESS ACCESSORIES eu keng taal au i f NESS QUANTUM DETECTORS The Ness Quantum range of high tech motion detectors includes passive infrared detectors dual technology microwave and infrared as well as ceiling mounted 360 detectors All Ness detectors are designed and manufactured using the most modern technology and techniques that ensure superior reliability and performance The Ness Quantum Pet Aware PIR and Pet Aware Dual have a superior ability to discriminate between household pets and unwanted human intruders Ness Pet Aware detectors make it possible to protect your premises with your pets indoors Up to 25kg animal DZ PET AWARE Peon D WF onsistent Efe ac Edo Bizue CCTV Products NESS CCTV PRODUCTS The wide range of Ness CCTV equipment allows your installer to design a professional state of the art system for your home office shop or factory Ness cameras include dome cameras Infra red illuminated cameras miniature hidden cameras and professional digital cameras Video monitors are available in CRT or flat screen LCD styles in sizes to suit all applications
7. gramming seeseeeeeeeeeeerrereerrereens 21 Entry Exit Timer programming cceeeeeeeeeees 22 Monitoring Ee Mae aed oe as 23 Ness ACCESSOMIES siisssicavicissiievevensvsacaniocacmewcsareces 24 25 Troubleshooting c cc sececseceseccesesetsecetesaeeensssesczensenes 26 Installation Record AAA 27 OPERATION SUMMARY eee eee teeta 28 NESS ECO8x FEATURES e 8 alarm zones e Supports up to 3 remote keypads e 15 user codes can be programmed to operate by keypad PIN or radio key e Optional Ness Radio Interface for fully integrated wireless security e Programmable 2 Area Partitioning can split the panel into two independent areas plus a common area e Home Mode allows partial arming eg perimeter security overnight e Day Mode feature allows daytime monitoring of fire doors coolrooms etc e Temporary Day Zone feature allows easy enabling disabling of Day Mode e Keypad Panic feature e Keypad Medical Alarm feature e Two button arming feature e Fire Alarm feature with different siren tones e Highly flexible zone to output mapping e Onboard Vibration Sensor Analyser with programmable sensitivity Use with Nessensor vibration sensors e Siren chirp and strobe flash on arming with radio key e Quiet chirps option on arm disarm by radio key e True Dynamic Battery Test actively tests the battery under load every hour e 2 programmable auxiliary outputs e Automatic reset fuses e Prog
8. gy On board sounder and test button for the sounder and radio transmitter A single battery powers the smoke detector and the transmitter Includes 9V lithium battery NESS ECO8x CONTROL PANEL USER S MANUAL 25 TROUBLESHOOTING SYMPTOM When arming a zone light is on or the keypad gives a long beep POSSIBLE CAUSE One or more detection device a PIR or reed switch may be unsealed REMEDY Find the cause of movement or close the door or window e 10 beeps from keypad e MAINS light is flashing e BATTERY light is flashing The mains power may be off or the panel s backup bat tery may be low or a Radio Device battery may be low Make sure the plug pack is plugged in and the power point is turned on The backup battery may need replacing call your installer 1 long beep from the keypad Invalid keypad entry Press the E button and try again 2 second siren at the end of Exit Delay time A zone was unsealed at the end of exit delay time Disarm the panel and check all zones The strobe light is flashing There has been an alarm within the last 72 hours Reset the alarm by disarming the panel and check the Alarm Memory Siren sounds while the panel is disarmed EXCLUDE light is flashing A 24 hour zone has been alarmed Housing Tamper Panic Button A zone s has been Excluded Reset the alarm by disarm ing the panel and call your installer Th
9. hain as well as wristwatch straps Ideal for use as a medical alarm for the elderly or infirm Central Station Monitoring is especially recommended when used for medical alarm purposes Includes long life lithium battery RADIO REED SWITCH Ness Radio Reed Switch for wireless door and window protection Includes long life lithium battery WIRELESS PRODUCTS NESS RADIO KEYPAD A unique fully portable radio keypad The Ness Radio Keypad provides totally wireless Arming Disarming of the ECO8x control panel Also operates Home Mode and provides a Panic alarm The Ness radio Keypad is suitable for use as a portable keypad or for adding an extra keypad in areas where it is not possible to install wires F PET AWARE Y D 7 R12 Radio PIR e R15 Radio PIR RADIO MOTION DETECTORS Ness R15 Radio PIR and Ness R12 Radio PIR for wireless motion detection Can be used in combination with Ness hardwired detectors in areas where it is not possible to install wires Includes long life lithium battery The Ness R15PET Pet Aware model detects humans but is immune to household pets Allows you to protect your home with your pets inside RADIO SMOKE DETECTOR TTT The Ness Radio Smoke Detector provides a fully wireless smoke II detection option which can trigger the ECO8x panel s siren s and dialler if required or as programmed by your installer The Ness Radio Smoke Detector uses Photo electric smoke detection technolo
10. he B light will turn off See page 20 for the entry and exit delay factory default settings 22 NESS ECO8x CONTROL PANEL USER S MANUAL MONITORED PREMISES TELEPHONE LINE MONITORING MONITORING STATION ANY TELEPHONE CENTRAL STATION MONITORING The Ness ECO8x control panel has an on board digital dialler which can send detailed alarm messages to a Central Monitoring Station The digital messages can include information about the zone or zones which caused the alarm tamper alarms low battery or mains failure reports and it can also by user number identify the users who arm and disarm the system AUDIBLE MONITORING As a lower security alternative to central station monitoring the panel can be programmed to send audible messages to a fixed or mobile phone The telephone number s to call need to be programmed by your installer When triggered by an alarm the dialler will call the programmed telephone number s and output the audible message for 45 seconds or until it is acknowledged The audible message consists of the warning words ALARM ALARM ALARM followed by the alarm message sent as a series of beeps Central station monitoring is highly recommended and is the most effective method of monitoring your alarm system For further information about 24 hour monitoring contact your installer or Ness Security Products ACKNOWLEDGING THE ALARM The person receiving the call
11. hirp will be delayed by If Cope Onty ArmnG has been enabled by your 5 Seconds installer The ARMED BUTTON will light up Leave the premises within the Exit Delay Time 3 beeps will sound at the end of Exit Delay Time The control panel must be armed in order to detect intruders Before arming all zones should be Sealed by making sure there is no movement in rooms protected by motion detectors Doors or windows protected by reed switches should be closed The panel cannot be armed if in Program Home Memory or Exclude modes or if it is in alarm User codes that are programmed as Arm Only codes can arm the panel either from the disarmed state or from Home Mode A keypad is supplied with the panel Operation by Radio keys is optional J Tall 10 beeps when you arm means Mains Power is turned off or the backup battery is low J J i One long beep when you arm could mean the panel is already armed or the keypad code is wrong if not using Shortcut Arming SIREN WARNING At the end of the exit time all zones should be Sealed If any are Unsealed the siren will sound for 2 seconds to indicate that those zones have been automatically excluded You should disarm the panel check the premises and then arm again Continual warnings could mean there is a problem with a detection device that zone may have to be manually excluded If a zone is Unsealed at the end of exit time and the auto exclude option is di
12. his code with a new code of your own choice TIMERS You can also re program the Entry Delay Time and Exit Delay Time if you need more or less time to exit and enter the premises MONITORING Your installer can program the ECO8x to report alarms via the onboard dialler to either your mobile phone or to a central monitoring station Ask your installer for details PROGRAMMING TO ENTER USER PROGRAM MODE From the disarmed state Press LE Master Cove The factory default Master Code is 123 The P button will light up in red while in User Program Mode TO EXIT PROGRAM MODE press L I L I The P button light will turn off NOTE 1 The panel will automatically exit Program Mode if the keypad is inactive for 4 minutes NOTE 2 The Panic alarm is be disabled while in Program Mode NESS ECO8x CONTROL PANEL USER S MANUAL 19 PROGRAMMING OPTIONS TABLE OPTION NO DESCRIPTION DEFAULT USER S NAME User Code 1 Master Code User Code 2 User Code 3 User Code 4 User Code 5 User Code 6 User Code 7 User Code 8 User Code 9 User Code 10 User Code 11 User Code 12 User Code 13 User Code 14 User Code 15 OPTION NO DESCRIPTION DEFAULT COMMENT Entry Delay Time 20 20 sec Programmable from 1 99 seconds Exit Delay Time 60 60 sec Programmable from 1 99 seconds Siren Reset Time 5 5 min Programmable from 1 99 minute
13. is is to indicate that one or more zones have been Excluded Cannot arm and the EXCLUDE light is on steady You are in Exclude mode Press E to exit Exclude mode TAMPER light flashing ALARM MEMORY light is flashing The 24 hour Tamper input has alarmed Housing tamper There are alarms in memory Call your installer To clear the ALARM MEMORY light view the Alarm memory otherwise the light will clear next time you arm the panel Cannot enter Program Mode When arm by radio key the Armed light on the keypad does not turn on immediately The panel is armed Or you may be attempting to enter program mode using one of the user codes The panel is waiting 5 seconds for a second press of the ON button to enter Home mode Disarm the panel before at tempting to enter Program Mode Try again using the Master Code This is normal operation when arming of Home mode by radio key is enabled 26 NESS ECO8x CONTROL PANEL USER S MANUAL INSTALLATION RECORD Date Installed Installation Company NEA Telephone Monitoring Company ECOS8x Telephone TIMERS User Programmable ZONE ASSIGNMENT Installer Programming Options Entry Delay Time P26E Seconds ZONE MAPPING TO l ZONE TYPES OUTPUTS Exit Delay Time P28E Seconds LU Siren Reset Time P29E Minutes T N Aa g T Ticl IplDigleloif l Biel S SIE SAACHEN Si ZIBleciaiael
14. lashing if installed reset the panel as above To check the cause of the alarm you can view the alarms in memory by entering Memory Mode Note Arm Only codes User codes can optionally be programmed to be Arm Only codes An Arm Only code can Arm the system but it cannot Disarm However if an Arm Only code is assigned to a radio key the radio key OFF button will arm and disarm 1 If Entry Beeps are enabled 2 In the event of an alarm the strobe light will flash for 72 hours or until the panel is reset 3 This is an installer programming function NESS ECO8x CONTROL PANEL USER S MANUAL 11 OPERATION To arm HOME Mode by KEYPAD n If the Home Mope SHortcuT is enabled by RADIO KEY Home mode arming by radio key must be enabled by your installer Or press User Cope B Home mode allows you to Arm selected zones while others are ignored Typically perimeter zones doors and windows can be monitored while you are at home Your installer must program which zones will be active in Home mode If an alarm occurs while in Home mode entering User Cope E will silence the alarm This will also Disarm the panel so remember to arm Home Mode again if needed Using the optional Radio Keys you can enter Home Mode by pressing either the OFF button or the ON button twice within 4 seconds or by pressing the AUX button RK4 radio key only These options must be enabled by your installe
15. le i s SUEAKODIEAHIEIEAKHNEAE ZONE DESCRIPTION KEE 2 EA a Blala N O oO AJOJN USER CODES User Programmable USER TYPE OPTION NO DESCRIPTION USER S NAME KEYPAD RADIO KEY User Code 1 Master Code User Code 2 User Code 3 User Code 4 User Code 5 User Code 6 User Code 7 User Code 8 User Code 9 User Code 10 User Code 11 User Code 12 User Code 13 User Code 14 User Code 15 NESS ECO8x CONTROL PANEL USER S MANUAL 27 KEYPAD OPERATION SUMMARY to ARM Press If the Arming Shortcut is enabled The panel must initially be disarmed or press User Cone or press USER Cope If Code Only Arming has been enabled for that user code Press USER Cope to DISARM To disarm and or reset alarms to arm HOME MODE Press Areal must initially be disarmed If the Home Mode Shortcut is enabled Home Mode can be used if the panel is fully disarmed or if only Area2 is armed see page ei 12 for more information KE User Cone PANIC alarm Press Fire amp Medical keys together If Keypad Panic is enabled KEYEADIDURESS Press 5 6 8 or 9 User Cope Keypad Duress allows the user to send a silent duress report while disarming if the system is Add one these digits in front of a user code when disarming being monitored by a central stati
16. n May 2006 Document Part Number 890 355 For products 106 030 ECO8x Control Panel ADSL NOTICE ADSL broadband data can interfere with the operation of your alarm dialler It is recommended that a quality ADSL filter be installed as per the filter manufacturer s guidelines in all premises with an alarm dialler installed All rights reserved No part of this publication may be reproduced transmitted or stored in a retrieval system in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of Ness Ness reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement 2006 Ness Security Products Pty Ltd ABN 28 069 984 372 CONTENTS FOatuneS acorn dee intel 4 Introduction EE 5 Keypad RE 6 Visual Indicators cies wc ieee 7 OPERATION System OvervieW sssseeeeeieeieeisererrerereesreererrsrrsens 9 MERDE een EA teed hl eeh e reen 10 Rule DEE 11 Home Mode elek ie is aii a eis 12 Keypad Panic Duress eececeeseeseeeeeeeeeneeeees 13 Keypad Medical Alarm AAA 14 Keypad Fire Alarim eceeeceesseesneereneeseeeeeneersnees 14 Excluding Zones avin eunnaiiaiidiciedcieen Seve 15 View Memory cccceceeceeeeeeeeeeeeeeteeeeeteeteeeetens 16 17 Temporary Day Zones seeren 18 19 PROGRAMMING Programming Options Table 20 User Code pro
17. odes press the E button and start again When you are required to enter your access code you are given five opportunities to enter it correctly After the fifth invalid attempt the alarm is activated requiring the correct code E to silence the alarm This prevents anyone trying to guess your code by entering random numbers AREA PARTITIONING Area Partitioning allows the zones to be split into two partitions Area and Area The panel then effectively operates as two separate systems sharing only the siren outputs and dialler USER CODE ASSIGNMENT A User Code assigned to an Area can Arm and Disarm only that Area User Codes assigned to both Areas will operate both Areas simultaneously COMMON AREA ZONES Zones assigned to both Areas are Armed only when Areal and Area are both Armed This allows the Common Area zone s to be shared by both Areas For example Office A and Office B operate as separate areas but the entrance foyer used by both offices is assigned to both areas meaning it will automatically Arm when both Areas have Armed The Common Area then automatically disarms when either Area1 or Area Disarms ARMING AREAS Arming and Disarming of Areas if enabled is carried out as normal from a single keypad or separate keypads installed in both areas or by Radio Key Area operation only applies to zones when they are in the Armed state This means that Day 24hr and Home zones are independent of the area opera
18. on This sequence will disarm the panel and send a Duress report by dialler to the central station Report Keypad Duress must be enabled by your installer EXCLUDE ZONES Press If the Exclude Shortcut is enabled EXCLUDE E can only be used when the panel is disarmed then Zone No Zone No Enter the zone EXCLUDE CODE E can be used anytime number s to be excluded then press to exit Exclude mode The Exclude light flashes constantly while zones are excluded Excluded zones are automatically Included next time the panel is disarmed
19. ontrolling all panel functions including Arming Disarming Home Mode Panic memory recall and much more e Keypad Codes can be 3 to 6 digits in length and can be individually programmed and deleted e User Code 1 is also the Master Code which is used to enter User Program mode e All User Codes are Keypad Codes by default User Codes can be programmed to be Radio Codes as required NOTES 1 Keypad Codes beginning with 0 zero can be programmed but they will not operate the panel This is an alternative method for disabling user codes 2 All codes must be unique to each other Codes are rejected if already used Some codes that are similar to existing codes may also be rejected 3 When re programming a Keypad Code the old code does not need to be deleted first The new code will overwrite the old code NESS ECO8x CONTROL PANEL USER S MANUAL BI PROGRAMMING Programming TIMERS STEP KEYSTROKES DESCRIPTION COMMENT 1 Enters User Program oe Press Master Cove Mode 9 The button will light up in red 2 Enter the option The existing time if any will Press Oe number for Entry be displayed by the keypad Delay Time 1 one digit at a time Or enter the option Or Press ele number for Exit Delay Time 3 Enter the new time in The new time will be dis New Time seconds Example played by the keypad one enter 25 seconds as digit at a time 25 E press EI A User Program T
20. ored by a central station DI NESS ECO8x CONTROL PANEL USER S MANUAL OPERATION How to EXCLUDE zones by KEYPAD Press If the ExcLube SHortcut is enabled Or press User Cope The Exclude light will turn on then press Zone No Zone No B Enter the zone number s to be excluded Zones 1 8 can be excluded then press to exit Exclude mode The Exclude light flashes constantly while zones are excluded Excluded zones are automatically Included next time the panel is disarmed If there is a problem with a detection device and the zone cannot be sealed when arming the panel then that zone can be Excluded so that it does not generate alarms When zones have been Excluded the EXCLUDE light flashes continuously in both the Disarmed and Armed state Zones can be excluded while the panel is either Disarmed or Armed See notes below NOTES Zone Exclude is not permanent Excluded zones are automatically included next time the panel is Disarmed Zones can be manually included by the same method as Excluding Simply use the Zone No E sequence to turn OFF the zone lights to be Included The method works only when the panel is Disarmed The User Cope E method works even when the panel is armed This method can only exclude the zones in the Area assigned to that code NESS ECO8x CONTROL PANEL USER S MANUAL 15 OPERATION Viewing the EVENT MEMORY
21. pre wm READY vunn mmm ina System indicators aaa A A D o Mounting holes with e I cover plug x 2 S anas L E ARM button D MEMORY button HOME button oO EI g EXCLUDE button FIRE button e c MEDICAL button 006 PANIC alarm Press FIRE and MEDICAL together if keypad panic function is enabled KEYPAD BEEPS MEANING d 1 BEEP Any key press J a 3 BEEPS Valid Command a d4 LONG BEEP Error Mains Power is off or Panel Battery is low or A Radio Device has sent a low battery signal or Telephone Line Fail has been detected d o 10 BEEPS DN NESS ECO8x CONTROL PANEL USER S MANUAL KEYPAD INDICATORS KEYPAD DISPLAY INDICATORS IN OPERATING MODE Pon asin KEYPAD LIGHT ZONE LIGHTS 1 8 OFF Zone is sealed Zone is unsealed Zone is in alarm ARMED Red Illuminated button Panel is disarmed Panel is armed or Area 1 is armed if using Areas HOME Home Mode is Panel is armed Day Mode enabled disarmed in Home Mode see page 18 Amber Illuminated button seng Normal Memory mode New alarm s in selected memory Red Illuminated button Get Normal Zone s are y Excluded Red Illuminated button Normal User Program Installer Program P PROGRAM Red Illuminated button Mode Mode ARM 2 O ARM2 Amber Area 2 is Disamed Area 2 is Armed BATTERY Normal The backup battery O partery Red is low MAINS Normal Main
22. r SH Press either the OFF button or the ON button twice within 4 seconds Or press the AUX button once RK4 radio key only if enabled The strobe light will flash briefly If required your installer can program the external siren to chirp twice when arming Home mode Notes on Home Mode and Areas Home Mode can be used if the panel is fully disarmed or if only Area2 is armed Home mode is not available when Area 1 is armed The panel can be armed in Home Mode if Area2 is already armed on these conditions e Area 1 must be OFF e Area 2 must be armed first and then Home armed not the reverse e Zones assigned to both Home Mode and to Area 2 will act as Home zones when both Area 2 and Home Mode are armed Note Home Mode arming when AREA 2 is armed cannot be done by Radio Key or by keyswitch 12 NESS ECO8x CONTROL PANEL USER S MANUAL OPERATION PANIC alarm by KEYPAD press Fire amp Medical keys together The keypad function may have been programmed to be either AUDIBLE to activate the sirens or SILENT to send a PANIC report by dialler if your system is monitored by a Central Station PANIC cannot be used while the panel is in Program mode by RADIO KEY Press and hold the PANIC button for at least 4 sec Note Your installer may also have installed a separate wired PANIC button Press User Cone E to reset a Panic alarm or press the OFF bu
23. rammable siren reset lockout e 30 event memory from keypad e Standard defaults to suit most applications e Easy programming by keypad or NessComms software All programming data is permanently stored in a non volatile memory All inputs and outputs are heavily protected against lightning and high voltage supply transients DIALLER e Full remote upload download by PC and modem using NessComms software e Contact ID Format for central station monitoring e Audible format feature e Phone line monitoring activates output e Dialler Listen in option for installers e Auto Test calls DTMF dialling e True dial tone detection ES NESS ECO8x CONTROL PANEL USER S MANUAL The Ness ECO8x microcomputer based 8 zone control panel is the heart of your security system Each Zone of the panel can be connected to one or more detection devices to protect separate rooms of your premises Detection devices may be wired to the panel or you can use optional wireless detectors Passive Infra Red motion detectors PIRs are used to detect motion of people or animals Pet Aware motion detectors can ignore pets and still detect people Reed Switches are fitted to windows and doors to detect opening Vibration sensors such as the Nessensor can be used to detect glass breakage or forcing of windows or doors Normally a zone is considered Sealed Activation of a detection device will cause the zone
24. s Siren times of longer than 5 minutes are contrary to noise pollution regulations in most areas Siren Reset Time applies to the internal and external siren outputs The strobe light will reset after 72 hours unless the panel is reset sooner 20 NESS ECO8x CONTROL PANEL USER S MANUAL PROGRAMMING Programming USER CODES STEP KEYSTROKES DESCRIPTION COMMENT 1 Enters User SE Press P Master Cone Groe The P button will light up in red 2 Enter the 3 digit The existing user code if Press Orrion No option number for any will be displayed by the the user code being keypad one digit at a time programmed 3 Enter the new user The new user code will be New Cone New Cone code twice for displayed by the keypad verification Keypad one digit at a time codes can be 3 6 digits long 4 To exit User EI EI Program Mode The P light will turn off A keypad code can be deleted by pressing at STEP 3 above When re programming an existing keypad code the new code will overwrite the old code A keypad code only needs to be deleted if you re not replacing it with a new code EXAMPLES The panel must be in program mode e To program User Code 1 to be 1234 Press P11E 1234 E 1234 E e To delete User Code 2 without programming a new code P12E E USER CODE PROGRAMMING RULES e Up to 15 Keypad Codes can be used at up to 3 wired keypads for c
25. s power is off O MAINS Red READY Zone s are unsealed Ready to arm QO READY Green or Power is off the panel or Panel is armed or phone line fault TAMPER Normal The Internal Tamper O TAMPER Reo input is in alarm RADIO Normal Receiving a A Radio Key or QO RADIO Red radio signal If other radio device radio fitted has low battery TAR Normal Dialler is on Phone line fault O LINE Red line or failure to communicate See page 17 for keypad indicators in Memory Mode NESS ECO8x CONTROL PANEL USER S MANUAL Sa OPERATION This section describes the operation of a typical control panel installation Keep in mind that your installation may vary depending on the selected options and equipment The operating instructions which follow will cover the most common options Consult your installation company if you require further information All control panel operations are controlled by the keypad except if an optional key switch or radio remote control is installed OPERATING RULES Generally the panel will be Disarmed Armed or Home modes provide different levels of security for your premises when you are home or away Three other temporary modes Program Memory and Exclude allow you to perform various operations The panel will automatically exit from these temporary modes if you do not press any buttons on the keypad in a 4 minute period If you make a mistake while entering any c
26. sabled the siren will sound for the duration of siren time default is 5 minutes This is an installer programming function Di NESS ECO8x CONTROL PANEL USER S MANUAL OPERATION To DISARM by KEYPAD Enter the premises via a Delay Zone Press User Cope E by RADIO KEY Press the OFF button once The strobe light will flash briefly If required your installer can program the external siren to chirp 3 times when disarming by radio key The ARMED LIGHT will turn off If there has been an alarm while the system was armed the Mewory light will be flashing See page 16 on how to read the event memory When you enter the protected premises through a delay zone the keypad responds with regular beeps as a reminder to Disarm You then have your programmed entry delay time to disarm the panel If the panel is not disarmed by the end of the entry delay time an alarm will occur By using the optional radio keys you may disarm your system from within your premises or from outside your entrance door There is also the option to Chirp the outside siren three times and briefly flash the strobe light to indicate that you have disarmed your system If you make a mistake when entering your keypad code press E and start again Five incorrect entries will cause an alarm The panel can be reset and the siren s silenced by disarming the panel If you arrive at your premises and find the strobe light f
27. sed Radio Keys can also Arm and Disarm Areas The control panel housing and the covers over external sirens are protected by tamper switches to detect someone attempting to disable the security system You can Exclude a zone or zones so that they are temporarily ignored and cannot generate an alarm Excluded zones become active again the next time the system is disarmed The control panel is fitted with a rechargeable backup battery to ensure your security system continues to operate if the mains power is interrupted This control panel automatically tests the battery every hour and whenever you Arm Disarm the panel Dynamic Battery Test Up to 30 previous events alarms are stored in memory and can be viewed at any time in Memory Mode 1 Keypad codes programmed as Arm Onvy will not reset the panel NESS ECO8x CONTROL PANEL USER S MANUAL 5 KEYPAD The ECO8x keypad provides important visual and audible indications and is the main interface for operating and programming the control panel The keypad features backlit soft touch buttons and bright easy to read indicators The Arm Home Memory and Exclude buttons are illuminated from behind allowing the system status to be seen at a glance There is also an option to blank all the indicator lights after four minutes of no keypad use This option must be enabled by your installer 4 2 3 a 5 6 7 e Zone indicators _ _ e 6 6 6 6 6 sess
28. tions Note Area partitioning is in addition to Home Mode Any zone may be allocated to any area DN NESS ECO8x CONTROL PANEL USER S MANUAL SYSTEM OVERVIEW 8 Zones for PIRs Door amp Window Switches Vibration Sensors Smoke Detectors ECO8x KEYPAD ECO8x Supplied MAIN HOUSING Radio PIRs Radio Reed Switches Radio Keypad Radio Smoke Detector TSU Internal Siren External Siren Strobe Light Auxiliary Outputs for optional connection to Electric Roller Doors Lighting Line Fail Output Radio Key Panic Output Radio Key AUX Output and more 17V AC Plug Pack Supplied Telephone Dialler Built in Telephone Lead Supplied See pages 24 25 for further information on the Ness range of wired and wireless accessories NESS ECO8x CONTROL PANEL USER S MANUAL 9 OPERATION To ARM the panel by KEYPAD When the READY light is on you can arm by TORO If the ARMING SHorTcuT is enabled by RADIO KEY Press the ON button once Or press User Cope E The strobe light will flash briefly If required your installer can program the external siren to chirp Or press User Cope once when disarming by radio key If Home Arming by Radio Key is enabled the c
29. to be Unsealed and may cause an alarm Detectors such as smoke detectors and panic buttons must be able to generate an alarm at all times regardless of the panel setting A zone with this assignment is called a 24 hour zone Some detection devices may be required to generate an alarm or warning only when the panel is Disarmed A zone with this assignment is called a Day zone Before leaving the premises you must Arm turn on the panel After arming the panel will ignore detectors during the Exit Delay Time to allow you to exit without triggering an alarm The system can be armed and disarmed using the keypad supplied or by optional Radio Keys When you enter the premises the panel will ignore selected zones for the Entry Delay Time and will not alarm if you disarm the panel during this allowed time INTRODUCTION When an alarm occurs it can be reset with a User Code or by optional Radio Key otherwise it will reset at the end of Alarm Reset Time Resetting an alarm stops the sirens and strobe light If an alarm is not reset the sirens will stop after the programmed time default is 5 minutes and the strobe light will stop after 72 hours Home mode allows you to Arm selected zones while others are ignored Typically perimeter zones doors and windows can be monitored while you are at home If you wish to split your alarm system into two areas with access limited to each area by code numbers then Area operation is u
30. tton on a radio key Keypad DURESS alarm by KEYPAD Press 5 6 8 on 9 User Cone Add one these digits in front of a user code when disarming This sequence will disarm the panel and send a Duress report by dialler if the system is monitored by a central station The DURESS alarm can be used to send a silent alarm to the central station that you are being forced to disarm the panel against your will That is you are disarming under duress To disarm and send a DURESS alarm prefix your User Code with one of the digits 5 6 8 or 9 when Disarming THE KEYPAD DURESS IS NORMALLY NOT ENABLED TO ENABLE THIS FUNCTION CONSULT YOUR INSTALLER DURESS ALARMS CAN ONLY USED BY SYSTEMS WHICH ARE MONITORED BY A CENTRAL STATION THE DURESS ALARM CAN BE PROGRAMMED TO SOUND THE INTERNAL SIREN RESET OUTPUT THIS OPTION IS OFF BY DEFAULT NESS ECO8x CONTROL PANEL USER S MANUAL 13 OPERATION Keypad MEDICAL alarm by KEYPAD s OO Sends a Medical Alarm report by dialler If this option has been enabled by your installer and the system is monitored by a central station The Medical Alarm does not sound the sirens Keypad FIRE alarm by KEYPAD Press e Sounds the siren using the Fire Alarm sound If Keypad Fire Alarm has been enabled by your installer And sends a Fire Alarm report by dialler If this option has been enabled by your installer and the system is monit