        Extech SDL100 pH/ORP/Temperature Datalogger
         Contents
1.    3  Momentarily press the LOG button to store a reading  The DATALOGGER icon will flash each  time a data point is stored      Usethe A and Y buttons to select one of the 99 data memory positions in which to record    5  To exit the manual datalogging mode  press and hold the LOG button for at least 1 5 seconds    The DATALOGGER icon will switch off     8 SDL100 EU EN V1 3 8 11    Automatic Datalogging    In automatic datalogging mode the meter takes and stores a reading at a user specified sampling  rate onto an SD memory card  The meter defaults to a sampling rate of one second  To change the  sampling rate  refer to the Setup Mode section  the sampling rate cannot be    0    for automatic  datalogging      1     2     Select the sampling rate in the Setup Mode  refer to Setup Mode section  to a value other than  zero    Press and hold the LOG button for at least 1 5 seconds  The meter will flash the  DATALOGGER icon at the selected sampling rate indicating that readings are now being  automatically recorded to the SD card    If a card is not inserted or if the card is defective  the meter will display SCAN SD indefinitely   In this case  switch the meter OFF and try again with a valid SD card    Pause the datalogger by pressing the LOG button momentarily  The DATALOGGER icon will  stop flashing and the sample rate will display for a short time  To resume logging simply press  the LOG button again momentarily    To terminate the datalogging session press and hold the LOG 
2.  operation  backlight and datalogger OFF   approx  14mAdc  With backlight OFF and datalogging ON  approx  37mAdc  With backlight ON add approx  12mAdc   365g  0 80 Ibs   meter only   Main instrument  182 x 73 x 47 5mm  7 1 x 2 9 x 1 9        Electrical Specifications  ambient temperature 23  C   5  C     All pH electrodes with a BNC connector are compatible    pH  mV    10  ohm    Manual    0 to 100  C  Automatic  0 to 65  C     pH7  pH4  and pH10  3 point calibration     0 to 14 pH 0 01 pH  1909 mV lo 1969 nV       0 02 pH   2d       0 5    2d   0 1      0 to 65  C 32 to 149  F   1C0   1 8  F      pH accuracy based on freshly calibrated meter       Copyright    2011 Extech Instruments Corporation  a FLIR company   All rights reserved including the right of reproduction in whole or in part in any form    www extech com    11 SDL100 EU EN V1 3 8 11    
3.  user    e RS 232 USB  The meter includes an RS 232 USB PC interface jack located on the lower right  side of the meter under the snap off compartment cover  The optional software kit  PN   407001A  includes a cable and a software program for streaming data to a PC        SD Card Information  e Insert an SD card  from 1G size up to 16G  into the SD card slot at the bottom of the meter  The  card must be inserted with the front of the card  label side  facing toward the rear of the meter     e Ifthe SD card is being used for the first time it is recommended that the card be formatted and  the logger s clock set to allow for accurate date time stamping during datalogging sessions   Refer to the Setup Mode section for SD card formatting and time date setting instructions    e European and USA numerical formats differ  The data on the SD card can be formatted for  either format  The meter defaults to USA mode where a decimal point is used to separate units  from tenths  i e  20 00  The European format uses a comma  i e  20 00  To change this setting   refer to the Setup Mode section     Manual Datalogging   In the manual mode the user presses the LOG button to manually log a reading onto the SD card    1  Set the sampling rate to    0    seconds as described in the Setup Mode section    2  Press and hold the LOG button for at least 1 5 seconds and the DATALOGGER icon will appear  on the LCD  the lower portion of the display will show    P N     N   memory position number 1   99  
4. User s Guide    EXT       INSTRUMENTS  A FLIR COMPANY    pH ORP Meter  SD Card real time Datalogger          Model SDL100          Introduction       Congratulations on your purchase of the Extech SDL100 pH ORP Meter  an SD Logger Series  meter  This meter displays and stores pH  from 0 to 14 00pH  and ORP   1999mV  readings  A  temperature probe  supplied  can be inserted to the meter to provide automatic temperature  compensation  Logged data readings are stored on an SD card for transfer to a PC  In addition  an  RS232 port allows data streaming to a PC  This meter is shipped fully tested and calibrated and   with proper use  will provide years of reliable service     Safety       International Safety Symbols    A    This symbol  adjacent to another symbol or terminal  indicates the user must refer to the  manual for further information     Meter Description       1     OS ON OF o    2 6 O    Y A  E O N o    a  a    Notes     pH ORP Sensor input BNC jack   Temperature probe input jack   pH ORP Measurement reading on LCD Display  Temperature reading on LCD Display    HOLD and Backlight Y key  MAX MIN key   SET and Clock key   PC interface jack   Reset button   Power Adaptor jack   SD card slot   ENTER and LOG key   Down arrow Y   Function key    Up arrow A   CAL key     OAN OO FW    Power ON OFF    key       Items 8  9  and 10 are located behind the snap off compartment cover on meter   s right side     Battery compartment  tilt stand  and tripod mount are located on the re
5. ar of the instrument    2 SDL100 EU EN V1 3 8 11    Getting Started    Power ON OFF   e Press and hold the power button    for at least 1 5 seconds to power ON the meter    e Press and hold the power button for 1 5 seconds to power OFF the meter    e This meter is powered by six  6  1 5VDC    AA    batteries or by optional AC adaptor  If the meter  will not switch ON please check that fresh batteries are installed in the rear battery compartment   refer to the battery replacement section later in this guide  or  in the case of the AC adaptor   check that the adaptor is connected correctly to the meter and to an AC source  refer to the AC  Power Adaptor section later in this guide         pH ORP mV Measurements    Selecting pH or ORP modes of operation  Press and hold the FUNCTION button for at least 1 5 seconds  the display will begin to toggle  between pH and ORP modes  Release the FUNCTION button when the desired mode is displayed        pH Measurement Range  pH measurements are displayed in the range of 0 00 to 14 00 in the upper  larger digit display area  of the meter s LCD  Measurements made outside of this range will yield dashes         on the meter s  LCD  The Temperature value is shown below the pH reading on the LCD  Refer to the  Measurement section for further information     ORP mV Measurement Range  lon selective ORP  Oxidation Reduction Potential  measurements are displayed in the range of   1999 mV  millivolts  in the upper  larger digit display area of the m
6. button for at least 1 5 seconds     When an SD card is used for the first time a folder is created on the card and named PHA01   Up to 99 spreadsheet documents  each with 30 000 readings  can be stored in this folder   When datalogging begins a new spreadsheet document named PHA01001 xIs is created on  the SD card in the PHAO1 folder  The data recorded will be placed in the PHA01001 xIs  document until 30 000 readings are reached    If the measurement session exceeds 30 000 readings  a new document will be created   PHA01002 xIls  where another 30 000 readings can be stored  This method continues for up to  99 documents  after which another folder is created  PHAO2  where another 99 spreadsheet  documents can be stored  This process continues in this same fashion with folders PHA03  through PHA10  last allowable folder      SD Data Card to PC Data Transfer    1     Complete a datalogging session as detailed in above in the previous sections  Hint  For the  first few tests  simply record a small amount of test data  This is to ensure that the datalogging  process is well understood before committing to critical  large scale datalogging    With the meter switched OFF  remove the SD Card    Plug the SD Card directly into a PC SD card reader  If the PC does not have an SD card slot   use an SD card adaptor  available at most outlets where computer accessories are sold      Power the PC and run a spreadsheet software program  Open the saved documents in the  spreadsheet software p
7. e lower LCD line    For Automatic Temperature Compensation  the external probe is connected to the meter and  inserted into the solution to be tested  The measured temperature of the solution is displayed on the    LCD     Display Backlight  To turn the display backlight ON or OFF  press and hold the backlight    button for at least 1 5  seconds     Data Hold  To freeze a displayed reading on the LCD  momentarily press the HOLD button  the HOLD display  icon will appear   To release the held reading  press the HOLD button again     Max Min Reading Record and Recall  For a given measurement session  this meter can record the highest  MAX  and the lowest  MIN   readings for later recall     il    2     Press the MAX MIN button momentarily to access this mode of operation  REC icon appears   The meter is now recording the MAX and MIN readings    Press the MAX MIN button again to view the current MAX readings  MAX icon appears   The  readings on the display are now the highest readings encountered since the REC icon was  switched on  when the MAX MIN button was first pressed     Press the MAX MIN button again to view the current MIN readings  MIN icon appears   The  readings on the display are now the lowest readings encountered since the REC icon was  switched on  when the MAX MIN button was first pressed     To exit the MAX MIN mode  press and hold the MAX MIN button for at least 1 5 seconds The  meter will beep  the REC MAX MIN icons will switch off  the MAX MIN memory will cl
8. ear  and  the meter will return to the normal operating mode     4 SDL100 EU EN V1 3 8 11    Setup Mode       Basic settings at a glance    To view the current configuration of the meter with regard to time  date  and datalogging sampling  rate press the SET button momentarily  The meter will now display the configuration in quick  succession  Repeat as necessary to observe all the information     Accessing the Setup mode    1   2     Press and hold the SET button for at least 1 5 seconds to access the Setup menu     Press the SET button momentarily to step through the available parameters  The parameter  type is shown on the bottom of the LCD and the current selection for that type is shown above  it    When a parameter is displayed that is to be changed  use the arrow keys to change the  setting  Press the ENTER button to confirm a change     Press and hold the SET button for at least 1 5 seconds to exit the Setup mode  Note that the  meter automatically switches out of the Setup mode if no key is pressed within 7 seconds     The available Setup parameters are listed below  Additional detailed information is provided  below this list     dAtE Set the clock  Year Month Date  Hours Minutes Seconds    SP t Set the datalogger sampling rate  Hours Minutes Seconds    PoFF Automatic power off management  Enable disable the auto power off function   bEEP Set the beeper sound ON OFF   dEC Set the numerical format  USA  decimal  20 00  or European  comma  20 00   SdF Format the SD me
9. eter s LCD  Measurements  outside of this range will yield dashes         on the meter s LCD     Connecting the pH or ORP Electrode  The measurement electrode connects to the BNC socket on the top left of the meter  If a pH  electrode is being connected to the meter for the first time  please perform a calibration as  described in the Calibration section of this user guide     Taking a pH or ORP Measurement  For pH measurements only  determine whether Manual or Automatic Temperature Compensation  will be used and then set up as required   Immerse the pH or ORP electrode into the solution under test and gently agitate the solution with  the probe  When the meter   s display has stabilized  note the reading  stabilization may require  several seconds up to several minutes  depending on the solution      When measurements have been completed  be sure to store the pH electrode in its protective cap  with a pH4 moistened sponge     3 SDL100 EU EN V1 3 8 11    Manual   Automatic Temperature Compensation  for pH measurements only     Ph measurements are most accurate when the temperature of the solution under test is known and  a temperature compensation factor is applied to the measurement  This is achieved using Manual  or Automatic Temperature Compensation    For Manual Temperature Compensation  the external temperature probe is not connected to the  meter and the temperature of the solution under test is manually entered in the Setup Mode  The  temperature entered is shown on th
10. he Temperature Compensation section for details   Rinse the electrode with distilled water to remove residual solution   Immerse the pH Electrode and temperature Probe  if used  in the 7 00 pH buffer solution and  agitate the solution gently with the Electrode   Allow the calibration to stabilize for 15 to 30 seconds and view the reading on the meter LCD  Press and hold the CAL button for at least 1 5 seconds until the CAL icon appears on the  display and then release the CAL button    Use the arrow keys to scroll to the 7 00 pH display      Press the ENTER button to save the calibration data    Repeat steps number 5 through 10 for the 4 00 pH and 10 00 pH buffer solutions    Repeat the entire calibration to ensure optimal accuracy  Remember to rinse the Electrode    before placing it into a new solution    7 SDL100 EU EN V1 3 8 11    Clearing pH Calibration data  1  From the normal operation mode  press and hold the CAL button for at least 1 5 seconds until  the CAL icon appears on the display and then release the CAL button    Use the arrow keys to scroll to the CLR display  3  Press ENTER and all calibration data will be erased    Datalogging and PC Interface    Types of Data Recording    e Manual Datalogging  Manually log up to 99 readings onto an SD card via push button press    e Automatic Datalogging  Automatically log data onto an SD memory card where the number of  data points is virtually limited only by the card size  Readings are logged at a rate specified by  the
11. he tilt    stand    2  Remove and safely place the battery compartment and screws where they will not be damaged  or lost   3  Replace the six  6  1 5V    AA    batteries  observing polarity   4  Replace the battery compartment cover with the two  2  Phillips screws   All EU users are legally bound by the battery ordinance to return all used batteries to  collection points in your community or wherever batteries   accumulators are sold   Disposal in the household garbage is prohibited   E    2    10 SDL100 EU EN V1 3 8 11    Specifications       General Specifications    Display   Status indicators  Measurement Units  Temperature probe  Datalogger Sampling Rate    Display update rate  Data Output   Operating Temperature  Operating Humidity  Auto Power OFF  Power Supply   Power Consumption    Weight  Dimensions    pH Electrode  Measurements    Input Impedance    Temperature  Compensation    pH Calibration    Measurement  H  mV  ORP     Temperature    52 x 38mm  2 x 1 5     Backlit LCD  Out of range        and low battery       pH  ORP    C  and   F   Thermistor  PN 850188     AUTO LOGGING  From 1 second to 8 hours 59 minutes  and 59 seconds  Note that a one  1  second sampling rate  can cause some data loss on slower computers    Memory Card SD memory card  1G to 16GB   Approx  1 second    RS 232   USB PC computer interface   0 to 50  C  32 to 122  F    85  R H  max    After 10 minutes of inactivity  can be disabled    Six  6  1 5 VDC batteries  optional 9V AC adaptor   Normal
12. mory card   t CF Select the desired unit of measure for temperature C or F   t SEt Manual Temperature value    Setting the Clock Time    1     di   3   4    Access the dAtE parameter    Use the arrow keys to change a value   Use the ENTER button to step through the selections   Press and hold the SET button for at least 1 5 seconds to exit to the normal operation mode  or  simply wait 7 seconds for the meter to automatically switch to the normal operating mode      The clock will keep accurate time even when the meter is switched off  However  if the battery  expires the clock will have to be reset after fresh batteries are installed     Setting the Datalogger Sampling Time  Rate     1   2     Access the SP t parameter     The sampling rate can be set from    0    seconds  manual log mode  up to 8 hours  59 minutes   and 59 seconds     Use the ENTER button to move through the Hours  Minutes  and Seconds digit groups and use  the arrow keys to change the digit values     Press the ENTER button to confirm the entry     Press and hold the SET button for at least 1 5 seconds to exit to the normal operation mode  or  simply wait 7 seconds for the meter to automatically switch to the normal operating mode      5 SDL100 EU EN V1 3 8 11    Enabling Disabling the Auto Power OFF Feature    1   2     Access the PoFF parameter    Use the arrow buttons to select ON  enable  or OFF  disable   With the Auto Power OFF  feature enabled  the meter will automatically switch OFF after 5 minutes 
13. of inactivity   Press ENTER to confirm setting     Press and hold the SET button for at least 1 5 seconds to exit to the normal operation mode  or  simply wait 7 seconds for the meter to automatically switch to the normal operating mode      Set the Beeper Sound ON or OFF    BD    Access the bEEP parameter   Use the arrow buttons to select ON  enable  or OFF  disable    Press ENTER to confirm setting     Press and hold the SET button for at least 1 5 seconds to exit to the normal operation mode  or  simply wait 7 seconds for the meter to automatically switch to the normal operating mode      Numerical Format  comma or decimal     European and USA numerical formats differ  The meter defaults to USA mode where a decimal  point is used to separate units from tenths  i e  20 00  The European format uses a comma  i e   20 00 to separate units from tenths  To change this setting     1     2   3   4    Access the dEC parameter   Use the arrow buttons to select USA or EUro   Press ENTER to confirm setting     Press and hold the SET button for at least 1 5 seconds to exit to the normal operation mode  or  simply wait 7 seconds for the meter to automatically switch to the normal operating mode      SD Card FORMATTING    1   Zi    Access the Sd F parameter     Use the arrow buttons to select YES to format the card  select NO to abort   Note that all data  on the card will be lost if formatting is attempted     Press ENTER to confirm selection   Press ENTER again to re confirm     The me
14. rogram  see example spreadsheet data screen below      Spreadsheet data example    4 A B G D E F G   1 Position Date Time CH1Value Chi Unit Ch2 Value Ch2 Unit  2 Y 8 12 2011 13 00 00 7 00 pH 25 00 Degrees C  3 8 12 2011 13 00 01 7 00 pH 25 00 Degrees C  4 3 8 12 2011 13 00 02 7 00 pH 25 00 Degrees C  5 4 8 12 2011 13 00 03 7 00 pH 25 00 Degrees C  6 5 8 12 2011 13 00 04 7 00 pH 25 00 Degrees C  7 6 8 12 2011 13 00 05 7 00 pH 25 00 Degrees C  8 7 8 12 2011 13 00 06 7 00 pH 25 00 Degrees C  9 8 8 12 2011 13 00 07 7 00 pH 25 00 Degrees C  10 9 8 12 2011 13 00 08 7 00 pH 25 00 Degrees C  11 10 8 12 2011 13 00 09 7 00 pH 25 00 Degrees C  12 11 8 12 2011 13 00 10 7 00 pH 25 00 Degrees C  13 12 8 12 2011 13 00 11 7 00 pH 25 00 Degrees C    9 SDL100 EU EN V1 3 8 11    RS 232 USB PC Interface    The optional 407001A software kit  software and cable  allows streaming of data to a PC via  the RS232 Output jack     AC Power Adaptor    This meter is normally powered by six  6  1 5V    AA    batteries  An optional 9V power adaptor is  available  When the adaptor is used  the meter is permanently powered and the power button will  be disabled     Battery Replacement and Disposal       When the low battery icon     appears on the LCD  the batteries must be replaced  Several hours of  accurate readings are still possible in this condition  however batteries should be replaced as soon  as possible     1  Remove the two  2  Phillips screws from the rear of the meter  directly above the top of t
15. ter will automatically return to the normal operating mode when formatting is complete   If not  press and hold the SET button for at least 1 5 seconds to exit to the normal operation  mode     Set the Temperature Units of Measure    C or   F     1     di  3   4    Access the t CF parameter   Use the arrow keys to select   C or   F   Press ENTER to confirm setting     Press and hold the SET key for at least 1 5 seconds to exit to the normal operation mode  or  simply wait 7 seconds for the meter to automatically switch to the normal operating mode      Set the Manual Temperature value    1     2   de  4    Access the t SEt parameter   Use the arrow keys to select the temperature of the solution under test in   C or   F   Press ENTER to confirm setting     Press and hold the SET key for at least 1 5 seconds to exit to the normal operation mode  or  simply wait 7 seconds for the meter to automatically switch to the normal operating mode      6 SDL100 EU EN V1 3 8 11    System Reset    If the meter   s keys become inoperable or if the display freezes the Reset button can be used to  reset the instrument     1     Use a paper clip or similar item to momentarily press the reset button located on the lower right  side of the instrument under the snap off compartment cover    After pressing the Reset button  switch the instrument ON by pressing and holding the  POWER key for at least 1 5 seconds  If using the power adaptor unplug the adaptor and then  plug it back in again to power 
16. the meter     pH Calibration procedure       pH Calibration Considerations    An ideal pH Electrode generates a linear mV output of     59mV per pH with OmV at a pH of 7 00   However  as time passes  the electrode ages and the mV output per pH is reduced  This is why  calibration is so important  The Electrode must be calibrated with the companion meter as often as  possible  In addition  the Electrode must be replaced when it has deteriorated or becomes defective   The meter must also be well maintained and calibrated for best results     Required Equipment for pH Calibration    1   Zi    pH Electrode  pH buffer solutions    pH Calibration Procedure    1     Prepare buffer solutions for 7 00 pH and either 4 00 pH or 10 00 pH  Use the 4 00 pH and 7 00  pH solutions for measurements that are expected to be on the lower side of the scale  Use the  7 00 pH and 10 00 pH solutions for measurements that are expected to be on the higher side of  the pH scale  Note that all three ranges can be calibrated for a full 3 point pH calibration if  desired   Connect the pH Electrode to the meter   Switch the meter ON by pressing and holding the power button for at least 1 5 seconds  Ensure  that the pH mode of operation is selected as described earlier in the Measurement section  Manually adjust the temperature compensation value  in Setup Mode  to match the buffer  solution temperature or use the supplied temperature probe for automatic temperature  compensation as discussed earlier  see t
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
2 - Mein Tchibo mobil  Dataflex Combo Glider 092  BENJAMIN CASTALDI  足 利 市 常見水源 5号井戸さく井工事 設 計 書 平成 25 年度  the PDF - Support  ERHARDT+LEIMER GmbH ELSCAN micro  Whirlpool 8700 Dishwasher User Manual  Mode D`emploi - G&G ARMAMENT  Manual de instrucciones Televisión de plasma  LG UN171 Quick Start Guide    Copyright © All rights reserved. 