Home

Automotive Power Errata Sheet TLE983x BD

image

Contents

1. be checked by software the LIN module will be properly enabled Implementation proposal 1 check bit SYS_SUPPLY_STS VS_UV_STS to be 0 2 then write 0x00 to register LIN CTRL_STS_1 3 then write 0x06 to register LIN CTRL_STS_1 LIN normal mode 4 3 Temperature calculation The formula to be used to calculate the junction temperature from the ADC output value is Tj C ADC_out 256 1 23 1 24 0 4955 1000 1 807 with 1 23 Ref Voltage ADC2 V 1 24 gain at differential input of ADC 0 4955 and 1 807 Temperature coefficients see chapter Temperature coefficients Errata Sheet 3 4 Rev 2 1 2013 02 26 TLE983x BD Infineon 4 4 VDDEXT does not automatically switch off in case of short circuit In case of short circuit the short circuit condition is signalled in VDDEXT_CTRL VDDEXT_SHORT but the VDDEXT is not switched off automatically Switching off needs to be done explicitly in customer software VDDEXT_CTRL VDDEXT_ ENABLE 0 Errata Sheet 4 4 Rev 2 1 2013 02 26 Edition 2013 02 26 Published by Infineon Technologies AG 81726 Munich Germany 2013 02 26 Infineon Technologies AG All Rights Reserved Legal Disclaimer The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics With respect to any examples or hints given herein any typical values stated herein and or any information regarding the application of the device Infineon Technologies
2. hereby disclaims any and all warranties and liabilities of any kind including without limitation warranties of non infringement of intellectual property rights of any third party Information For further information on technology delivery terms and conditions and prices please contact the nearest Infineon Technologies Office www infineon com Warnings Due to technical requirements components may contain dangerous substances For information on the types in question please contact the nearest Infineon Technologies Office Infineon Technologies components may be used in life support devices or systems only with the express written approval of Infineon Technologies if a failure of such components can reasonably be expected to cause the failure of that life support device or system or to affect the safety or effectiveness of that device or system Life support devices or systems are intended to be implanted in the human body or to support and or maintain and sustain and or protect human life If they fail it is reasonable to assume that the health of the user or other persons may be endangered
3. Cfineon eae iste TLE983x BD Microcontroller with LIN and Power Switches for Automotive Applications TLE983x Errata Sheet Rev 2 1 2013 02 26 Automotive Power Infineon Errata Sheet Rev 2 1 2013 02 26 TLE983x BD Microcontroller with LIN and Power Switches for Automotive Applications Overview This document lists the errata of these variants of the TLE983x BD device TLE9832QV and TLE9832QX TLE9832 Data Sheet Rev 1 1 TLE9832 2QX TLE9832 2 Data Sheet Rev 1 1 TLE9833QX TLE9833QX Data Sheet Rev 1 1 TLE9834QX TLE9834QX Data Sheet Rev 1 1 TLE9835QX TLE9835QX Data Sheet Rev 1 0 1 Stop Mode Entry and Exit The Stop Mode needs to be entered and exited with a special configuration of the PLL Otherwise the system can exit Stop Mode only with Reset Workaround Before entering Stop Mode the following flag needs to be set just before the execution of the Stop Mode command SFR_PAGE _ su6 noSST switch to page6 OSC_CON 0x02 set intosc force to 1 switch async to internal PLL clock _nop_ needed for wakeup _nop_ _nop_ Revision History 2 1 2013 02 26 Previous Version 2 0 2012 07 27 Major Changes Chapter 3 and 4 4 added Errata Sheet 1 4 Rev 2 1 2013 02 26 TLE983x BD Infineon Directly after exiting Stop Mode the setting has to be cleared by using the following commands SFR_PAGE _su6 noSST switch to page OSC_CON amp 0x02 se
4. ata Sheet 2 4 Rev 2 1 2013 02 26 TLE983x BD Infineon First recommendation ensure an input signal rise time of lt 15us If this is not possible 3 cases need to be distinguished In case only rising edges are evaluated no workaround is required In case only falling edges are evaluated the errata described above occurs No workaround is available for this case In case both edges are used for interrupt generation but depending on the edge different actions should be taken e g in CCU6 following workaround can be used Table 1 rising edge signalled falling edge signalled action no no no action no yes handle as falling yes no handle as rising yes yes handle as rising 4 Application hints 4 1 LIN overcurrent shutdown In the design step BD the automatic LIN overcurrent shutdown has been removed The LIN transceiver is not disabled automatically any more the protection is ensured by the overcurrent limitation feature The overcurrent events is signalled in LIN OC_STS and needs to be handled by software interrupt or polling in case it appears in the specified LIN operational range 4 2 LIN Transceiver enabling with slow ramping With the default setting of register PCU_CTRL_STS 2 the LIN Transceiver is disabled whenever VS under voltage condition is met VS lt 5 5V It has to be ensured by software sequence that only after leaving the VS under voltage condition VS gt 5 5V which can
5. t intosc force to 0 PLL internal oscillator OSC PLL is selected synchronously Please note Register OSC_CON is password protected Before it can be modified it needs to be unlocked Planned fix description will be updated in the User Manual No fix in silicon planned 2 Temperature coefficients The temperature coefficients in the corresponding data sheets are not valid The valid coefficients are Output voltage Vtemp at To 273 K 0 C 0 4955 V was 0 5365 V before P_5 8 23 Temperature sensitivity b 1 807 mV K was 1 834 mV K before P_5 8 25 Workaround use the valid coefficients in software to calculate the junction temperature 3 Edge Detection on GPIOs requires rise time lt 15ys The edge detection on GPIO P0 x P1 x P2 x input signals requires a rise time of lt 15us 20 80 of 5V Errata description functional limitation for rise times gt 15yus A rising edge is always signalled correctly as rising edge but occasionally signalled as falling edge as well The opposite case works as expected A falling edge is always signalled correctly as falling and never signalled as rising edge The wrongly detected falling edges have influence on following functionality Interrupt generation Edge counter Timer start based on detected edge All functional blocks that evaluate falling edges on GPIO input signals are affected e g CCU6 in capture mode Timer external interrupts EXTINT UART Workaround Err