1. Model AT B8866 Version 1 0 Users Manual VID UNS IO corroe ras 1 A FO Ur sata 1 3 Technical parameter ccc cece cce eee eens 3 ZI LUSIFALON asesoran 5 Function definition of icons _ 5 6 Function definition of buttons 6 A ete ease ee sense Y 8 Measurements 8 1 Body temperature cccccccccccncccccnnnnnccnnnnnoo 8 8 2 Object temperature cece cece ee es 9 8 3 Exceeding measurementrange 5 10 9 Battery replacement ccc cena ee 11 10 Maintenance amp tipS ccc cece cece 11 11 Trouble shooting cece eee 12 1 In this Box The box should have contained 1x Thermometer 2 X AA battery 1x User s manual e Uses reliable sensor made in German e All new amp patented probe design ensures high accuracy e Excellent adaption to ambient temperature e Accurate and reliable even under complicated surrounding e Body mode and object mode available One switch to change mode e Beeper for fever or high temperature alarm value can be defined by user e Automatic recall of last reading Large LCD with back lit C F reading available O Automatic shut off 3 Technical parameters Measurement method Non contact Effective distance 5cm 8cm 35 5C 42 9C Range Body 85 9 F 109 2 F l OC 118 C Object 32 F 244 F B
2. installed e It is not allowed to put the thermometer in any liquid or expose to strong sunlight or extremely low temperature e Strong crash or hit to the product will cause its damage e Do not dismantle this thermometer by yourself e Keep the thermometer from children s reach e Do not use the thermometer under circumstance of strong electromagnetic interfere e The measurement results are probably fluctuating due to improper measurement ways Please practice adequate measurements in order to improve your skill The measurement results can not supersede a doctor s diagnosis e Special maintenance is unnecessary for this thermometer Please e contact distributor or manufacturer in case of malfunction 11 Trouble shooting Description Solutions 1 Breeze water sweating cosmetic on forehead may affect measurement 2 Check deviation value setting Defaulted value is 0 8 C 3 While if the testing environmental temp changes so enormously or if the thermometer is used LCD display directly from high temp object to very low LO Or nl temp one the measurement difference will happen The thermometer should be kept in a relative stable environment for 10 minutes to get heat balance before starting a new measurement 4 Ensure measurement distance is 5cm to 8cm No response 1 Take out and reassemble battery when pressing 2 Check if the thermometer is under menu setup measurement In procedure of menu se
3. off invisible Body temp Body mode Buttons Description Measurement mode E Objecttemp Object mode Body object To switch measurement mode between human body and object R Menu Isi Reading C Celsius reading Activates menu and save setting erate c Fahrenheit reading Increases parameter or select relevant parameter when setting parameter Reading HAAR Temperature value _ Reduces parameter or select relevant parameter when display U setting parameter Memory Temperature value of last measurement User can change reading scale between Celsius or Fahrenheit switch on or switch off beeper set alarm value set deviation value and change measurement mode between human body or object Please refer to below chart F 1 Reading scale oF setting Beeper on off Alarm value Decrease Increase Effective range setting 0 1 C 37C 42 C Deviation value Decrease Increase Effective range setting 0 1 C 0 1 C en ie SAVE Save and automatic shut off A Notice 1 Temperature under human body mode is obtained from dynamic compensation of environmental temp and forehead surface temp 2 Object temperature mode is to test surface temperature of an object The temperature get from forehead under this mode is merely temperature of forehead surface but not body temperature 3 Deviation setting is able to adjust measurement value from 0 C to 3 0 C according to testing distanc
4. e surrounding temperature skin difference etc Defaulted value is 0 8 C For example if the tested body temp is 36 2 C while the temp is supposed to be 37 0 C F 4 to set up the value and adjust to 1 6 C then the measurement value will be 37 0 C 8 Measurement 8 1 Body temperature e Press measurement button to turn on thermometer and it displays boot screen fig 8 1 After POST and two beeps it will display value of last reading and be ready for measurement fig 8 2 e Make sure the thermometer is under body mode e Keep distance at 5cm to 8cm from upper eyebrows to the probe fig 8 3 Press measurement button and when it gives a beep measurement is finished and value will be displayed fig 8 4 If measurement value is exceeding alarm value Defaulted value is 38 C itgives beep beep beep asa indication e After measurement if the thermometer is idle in 30 seconds itwill display OFF fig 8 5 and givesa beep and shut off automatically Object temp fig8 1 fig8 2 fig8 4 fig8 5 OQ 5 80M So fig8 3 A Notice 1 Keep the sensor and probe cavity clean before and after use 2 To ensure the accuracy of measurement it is recommended to start measurement after ten minutes when carrying the thermometer to a new environment 3 Wait for 10 minutes to measure body temperature after measuring extremely high temperature or ex
5. isplays Hi fig 8 10 and gives beep beep beep beep Object mode When measurement value is lower than 0 C it displays Lo fig 8 11 and gives beep beep beep beep When measurement value is higher than 118 0 C it displays Hi fig 8 12 and gives beep beep beep beep Notice When surrounding temperature is lower than 10 0 C or higher than 40 0 C it displays Err It s not allowed to measure or accuracy is not assured Err d fig8 9 fig8 10 fig8 11 fig8 12 fig8 13 9 Battery replacement e Open the battery lid and take out exhausted battery Put into 2 AA alkaline batteries and close up battery lid After new battery is installed thermometer will give Beep Beep If there s no beeps check if the positive and negative pole is correct see fig 9 1 Notice fig9 1 1 Take out battery in case the thermometer is not used for long period Don t put the battery to fire 2 Dispose battery according to local regulations 10 Maintenance amp tips e Make sure the sensor and probe cavity is clean otherwise it will affect accuracy Cleaning method for probe 1 Use the cotton stick or soft cloth with water or alcohol to wipe the casing 2 Use the cotton stick or soft cloth with alcohol to wipe the sensor surface or probe cavity gently Don t use thermometer before alcohol is vaporized e Read this manual book thoroughly before use Make sure battery is well
6. ody 0 2 C 0 4 F Accuracy Object 1 00 1 87 Resolution 018 F 100 40 50 F 104 F OTR Conair RH 80 Non condensing 25 C 55 C 13F 131 P RH 90 Non condensing Storage condition Power supply d c 3V 2AAalkaline Battery When offs10uW Power consumption When measurement 30mWwW Power level indicator Indication for low power level Memory Automatic recall of last reading Display LCD back lit display Reading scale Celsius or Fahrenheit Automatic shut off In 30 seconds Dimensions 93mmx153mmx41mm Net weight 125g EN60601 1 EN 12470 5 Standards ASTM 1965 98 4 Illustration Setting buttons Probe cover LCD display Probe Measurement button Handle 153 0 mm Product label 41 0 mm MN L Lot label 5 Function definition oficons 6 Function definition of buttons Function l definition con Details Measurement mode When iti The battery is in low lever but the vhen ICIS thermometer is functional properly a visible Please replace battery asap Object Body The battery is exhausted and ther Battery level oe mometer can not function properly Please replace battery immediately be Menu When itis ni Invisible Battery power is sufficient ver visible Beeperison Menu Setting Beeper When it is Beeper is
7. tremely low temperature objects 4 Wait for 5 minutes to start a measurement when a measuring target object or human is from an environment with enormous difference in temperature 5 Breeze water sweating cosmetic on forehead may affect measurement Do not measure body temperature in 30 minutes after exercise bath or meals 8 2 Object temperature e Press measurement button to turn on thermometer fig 8 6 e Make sure the thermometer is under object mode fig 8 7 e Keep vertical distance at 5cm to 8cm from object to measu rement probe Press measurement button and when it gives a beep measurement is finished and value will be displayed After measurement if the thermometer is idle in 30 seconds e it will display OFF fig 8 8 and gives a beep and shut off automatically cng nce JUN un fig9 6 fig9 7 fig9 8 Notice 1 The value under this mode is object surface temperature instead of core temperature 2 The defaulted infrared emissivity is 0 95 The reading will be deviated from the real temperature according to different emissivity Forexample the reading on stainless steel will be obviously lower than real temperature BE CAUTIOUS FOR SCALDING 8 3 Exceeding measurement range Body mode When measurement value is lower than 35 5 C it displays Lo fig 8 9 and gives beep beep beep beep When measurement value is higher than 42 0 C it d
8. tting thermometer is button unable to measure and therefore no response 1 Take out battery and install battery again 1 Check if the beeper is switched off No display or improper display No beeper Shut off right after switching on 1 Check battery level or take out and install the battery again