1.       Specify a location     Microsoft Windows Update       Back Cancel         The following message appears now  follow the on screen instructions     Found New Hardware Wizard       Driver Files Search Results  The wizard has finished searching for driver files for your hardware device        Other PC  Bridge Device    Windows found a driver for this device  To install the driver Windows found  click Next     6 edo dasbm  int    Cancel         Found New Hardware Wizard    Completing the Found New  Hardware Wizard       DO DASEM    Windows has finished installing the software for this device     To clase this wizard  click Finish        Eancel       Knife Edge Profiler Manual    19    3  After completion of PCI card installation  when the device is configured successfully  one can check in System Properties  Device Manager Tab and see that    DAS  Components    now contains the    DO DASBM       device     ml       Device Manager    LA Action View       SR pLAGRARY 2   G  ac er    i v DAS Component  es  DO DASBM  H  H  Disk drives    H     i Display adapters   B28  DVD CD ROM drives   H  Floppy disk controllers   ee Floppy disk drives   H  IDE ATA ATAPT controllers   E  aap Keyboards   2s Mice and other pointing devices  3               Monitors   Ea  BY Network adapters   H     PCMCIA adapters   H Ports  COM  amp  LPT    B  agi Sound  video and game controllers    nE Mm  System devices  H        Universal Serial Bus controllers       Installation for Windows NT 4 0  The Kn
2.      Knife Edge Profiler Manual 90    Relative Total Power    The rotating drum in the detector head contains multiple knife edge apertures  As an aperture  passes between the laser beam and the stationary power sensor  there is a period of time where  the entire beam is allowed to reach the sensor  At this point the Knife Edge Profiler can measure  the total power of the beam     The power reading is adjusted based on the system Wavelength setting and the wavelength  response curve for the detector and the transmission of the current filter     For details on minimum detectable power  measurement resolution  maximum power and  damage threshold limits see the appropriate detector head specifications     Power Accuracy    The silicon detectors are calibrated with and without the filters for power accuracy at 633 and 830  nm  The InGaAs detector is checked for power accuracy at 830 nm  The system is designed for    10  accuracy at the specified wavelengths  Accuracy at other wavelengths is unverified   Therefore the Knife Edge Profiler does not provide absolute power accuracy at this time  Please  consider the Power reading to be Relative     If absolute power accuracy is desired  the Knife Edge Profiler power reading can be hand  calibrated using a power meter  If the Knife Edge Profiler reading needs to be adjusted  a Filter  file can be created that provides the necessary correction at the given wavelength     Beam Width    The Beam Width is measured at a clip level     A cl
3.     35 2 mm  W  x 105 mm  H  x 87 5 mm  L   22 OZ    10 uW   Power up to 5 mW   0 1 uW resolution    10     1 W mm  with total power less than 5 mW at sensor  10 uW cm  to 10 W mm    no filter   3mm to 3 um    width  lt  100 um  0 1 um  width  gt   100 um  1 0 um    1 um   15 um    5 4  0 1 mm back from front surface of Head   0 5   0 18 mm back from internal front surface of  entrance hole     5 Hz  see Speed Issues   2 5 m long attached to the head     The InGaAs head does use filters due to mechanical  constraints     We allow blade eccentricity of     15 um for the KEP 3     Knife Edge Profiler Manual    83    KEP 3 SL Detector Head    KEP 3    Entra  Pere lea       Front Y iew  Spectral Response    Number of knife edges  Sensor Input Aperture  Dimensions   Weight    Minimum Detectable Power    Maximum Power  633nm    Relative Power Measurement    Power Measurement  Accuracy    Damage Threshold  Optical Dynamic Range  Beam Size Range  at 1 e    Beam Width Resolution    Beam Position Resolution  Beam Position Accuracy  Distance to Image Plane    Maximum Update Rate  Cable  Filters     Dimensions in mm        h 35 2 es  co    Thread  Side Yew  350 1100  3  5 mm Circular  35 2 mm  W  x 105 mm  H  x 87 5 mm  L     Hear View    22 OZ    10 uW   No filter  Power up to 5 mW  NG4 filter  Power up to 50 mW  NG9 filter  Power up to 1 W    0 1 uW resolution   5     200 W mm  with total power less than 5 mW at sensor  10 uW cm  to 10 W mm    no filter   5 mm to 3 um    width  lt  100
4.    Cancel   System      Help      Units  Select the appropriate units for the power meter display   mW  uW and dBm     Filter  The Load filter button will display a Windows open dialog  This dialog will allow  the user to select the  flt file corresponding to the installed filter     Display  The Display Radio Buttons allow the user to select the desired presentation     Status Power  Toggle between displaying the power reading at the Status Bar and  disable the power reading display         Units  The Power Units are selected from the Power Setup dialog     The Units option enables changing the units on the power meter display  The possible values are   mW  uW and dBm     Both the needle scale and the numerical power display are updated accordingly     Set the desired power units with the Radio Button  The units can also be selected by clicking on  the units displayed in the Power Window  Each mouse click will cycle to the next unit  UW  mW  and dBm      Power Display  The Display option is selected from the Power Setup window   This option provides three types of presentations for the power meter     1  A graphical needle graph and a small digital presentation for the measured power   2  A large digital presentation for better visibility at a distance     3  A bar graph presentation of the measured power     Display      Neede    Digt   Bar For the appropriate display check the Radio Button     Knife Edge Profiler Manual 45    Power Setup          Range  mi4  Alarm Limits  
5.    KEP Series    Knife Edge Profiler    GO Newport       Users Manual       Nevwvport  E      EU Declaration of Conformity    We declare that the accompanying product  identified with the CE mark  complies  with requirements of the Electromagnetic Compatibility Directive  89 336 EEC and    the Low Voltage Directive 73 23 EEC     Model Number  KEP Series  a Knife Edge Profiler    Year C     mark affixed  2002  Type of Equipment   Information Technology Equipment    Standards Applied     Compliance was demonstrated to the following standards to the extent applicable     e EN 55022      Limits and methods of radio interference characteristics of  information technology equipment  Generic emission standard     Part 1   Residential  Commercial and Light Industry     e EN 50024      Electromagnetic Compatibility  EMC   generic immunity standard      Part 1     Residential  commercial and light industry           Alain Danielo   VP European Operations   Zone Industrielle   45340 Beaune la Rolande  France    Knife Edge Profiler Manual    PIREA     Dan Dunahay  Director of Quality Systems  1791 Deere Avenue  Irvine  Ca  USA    Warranty   Newport Corporation warrants that this product will be free from defects in material  and workmanship and will comply with Newport s published specifications at the time  of sale for a period of one year from date of shipment  If found to be defective during  the warranty period  the product will either be repaired or replaced at Newport s  option    
6.    This option is provided to enable a remote operation of the application program   Press the Server Icon EJ at the ToolBar or select Server Mode from Options Menu   The following blinking icon now appears at the ToolBar adjacent to the Time field     Resting the mouse cursor at the blinking icon the Server Host Address is displayed  for  identification of the Client computer via TCP IP protocol      Knife Edge Profiler Manual 70    OP 15 44 16 O8 Apr 2004    _    Server Host Address  COMPAQ    At the remote computer  Client  there is a need to install the software from the same system CD  disk  and start the program  The following message will be displayed        Hardware Error  XX  Knife Edge Profiler system cannot be started  Please contact your  Provider     Press OK     The following message will be displayed      Would you like to initiate a remote client application     press Yes     The following screen will be displayed              Connect To      33     Enter details for the host that you want to call     Host address   EOM PAg  Fort number  f oo    Connect using   TCPAP  Winsock      i Cancel   Help      There is a need to input the Host Address name of the Server computer  After pressing OK  a  Test Hardware routine will be performed  From this stage and on  the remote client computer will  be running the same software and all measurements and analysis functions performed will be  done as if it was the main computer which hosts the hardware     User Data    The 
7.    is the transmission rate for the RS 232 link  The possible values  are  110  300  600  1200  2400  4800  9600  19200  38400  57600 and 115200         Link Setup    General Port Settings      Bits per second     Data bits  This setting must match the corresponding setting on the  O receiving computer   Parity Bits     Stop bits     OF    Cancel   Help      Parity Bit    The Parity Bit option is accessed from Link Setup  This setting should only be changed when  utilizing the RS 232 communication link     Link Setup    General Port Settings      The Parity Bit determines whether or not a parity bit is to be  transmitted  The possible values are  None  Odd  Even   Space and Mark     Bits per second     Data bits     Parity Bits  This value must match the corresponding setting on the    Stop bits    receiving computer        Knife Edge Profiler Manual 38    Data Bit    The RS 232 data bit selection is accessed from Link Setup         Link Setup    General Port Settings      Bispersesond  5500   The Data Bit setting determines the number of bits utilized  Heine B k Pa RS 232 transmission  The possible values are 4 5 6 7  Parity Bits  This setting must match the receiving computer setting     Stop bits  ke    OF    Cancel   Help      Stop Bit    The Stop Bit option is accessed from Link Setup  This setting should only be changed when  setting the RS 232 link parameters          Link Setup    General Port Settings      Stop Bit determines the number of stop bits to be  transmitte
8.   6  Press COMPLETE button  when you are done with the filter creating procedure  Knife   Edge Profiler will then display a file storage dialog  Press CANCEL button to cancel the    Knife Edge Profiler Manual 31    attenuation data file creation     In the file dialog there is no need to change the  File Type  because FLT is the default     8  The Knife Edge Profiler data files are located in the    Data    folder in the Knife Edge  Profiler directory  The Knife Edge Profiler directory is located in    Program Files    by  default     9  Type a filename for the filter file in the box below the word  File name   The filename  must be less than 9 characters and contain no spaces  There is no need to have the file  name end in  FLT as the program will automatically save the file with that extension     10  Click OK     S  Print       Print    can be selected from the File menu  or via the button on the ToolBar     Print window Fi  Image File Ctrl I    Print    allows the user to print an entire saved data file  Saved data files include a pre saved text  file or a pre saved BMP file    To select and setup a specific printer  select Print Setup from the File menu  The printer must  be selected prior to selecting Print       Print    allows the user to print an entire saved data file  The data is printed in the same format as  shown on window utilizing the View File option    To select and setup a specific printer  select Print Setup from the File menu prior to selecting  Print    
9.   88    PCI Interface Board    The Knife Edge Profiler uses a plug in interface board to digitize and store the information from  the detector head        PCI Interface Board     F The interface board is a static sensitive electronic device and should be handled  with care to avoid exposure to static voltages     e Size  1 2 card length PCI    e Bus  32 bit PCI Bus    e Weight  0 42 Ibs    e Dimensions  7 33 inches long x 4 26 inches tall     e Power input requirements  typical    Running software   5V   0 6 A   12V   0 08 A   12V   0 12 A   3 3V   0 5A   No software running   5V   0 32 A   12V   0 075 A   12V   0 13 A   3 3V  0 1A    e Power consumption   Running software  7 3 Watts Typical   No software running  4 3 Watts Typical     e Ambient Operating Temperature  10   70  C   e A D Converter  20 MHz sample rate at 8 bits per pixel    e Storage Memory  8 KB    e CE Mark  Conforms to all applicable CE Mark standards     PCI Interface Board Card Edge     There are two connectors on the back bracket of the interface board  a 15 pin and a circular 8 pin   The 15 pin connector is connected to the detector head  The Auxiliary connector is used for  future devices     Detector Head Connector Auxillary Connector       Interface Board Card Edge    The slide switch is used to select the type of head that is connected  This switch is set at the  factory to match the detector head purchased  This switch should only be moved when power is  off     Knife Edge Profiler Manual 89     amp
10.   Calculations Summary    This topic provides a brief description of the beam analysis calculations performed by the Knife   Edge Profiler      F Please be aware of Accuracy issues that can affect these calculations     Accuracy    The following topics provide information on how to optimize the Knife Edge Profiler to achieve the  highest measurement accuracy     The accuracy of all calculations will be affected by beam peak intensity  centering  size  and  background noise  To insure optimum measurement accuracy the following items should be  properly maintained   e The beam spot size should not exceed the recommended minimum or maximum beam  diameter for the detector head being used  see Detector Heads   See Resolution for  issues about the number of data points used in the calculations     e The beam position should be centered in the sensor area with no beam area overlapping  the edge of the input aperture on the detector head     e The beam incidence should be normal to the face of the detector head     e The background noise in the beam image can affect the calculated results  Ensure that  all sources of background noise have been eliminated if possible   See Background  Noise     e When measuring beams smaller than 100 microns or beams that are far from Gaussian  shape  High Resolution can be especially effective     e The successive Averaging feature can also be used to smooth noise and beam  variations     Background Noise    Several sources of background noise can co
11.   In practice  these controls can be used in any environment that allows interaction with  ActiveX servers  although it hasn t been tested with tools other than those mentioned      Registration    The ActiveX controls will be registered the first time that the Knife Edge Profiler software  application is run     Examples    Examples of a LabVIEW and a Visual Basic application are provided with the installation CD disk   All examples assume a rudimentary knowledge of the respective development platforms     Knife Edge Profiler Manual 100    Active X Details    Types  1  kepUpdated  a  Flag used to inform calling application if camera has made a new measurement   used with the DataUpdated property   Also used on startup to inform calling  application that the camera has been initialized  used with the SettingsUpdated    property   b  Values  i  KepNotUpdated  0  Settings Data not yet updated   ii  kepUpdatedSusccessful   1  Settings Data have been updated   iii  kepFailed    1  Failed to set up initial settings     Events  in Visual Basic only     Note  Events can only be used in Visual Basic applications  In order to use events  the  EventsEnabled property  described below  must be set to TRUE     1  DataUpdated  Knife Edge Profiler has made a new measurement  2  ErrorMessage  Knife Edge Profiler is reporting an operational error  as a code and as a  text message      Properties    1  ClipLevel  a  Used to get or set the Clip Levels of the profiles  2  EnableEvents  a  Used t
12.   The  ZOOM ON  message is displayed inside the position screen area   Toggle between Zoom Position On and Off with the Check Box     Position Grid   The Position Grid is selected from the Position Setup window    The Grid option turns on the grid pattern displayed in the position plot area   Use the Check Box to turn the Grid ON     Position Setup      Colors  The Colors tab allows the selection of  various plot colors  Each color selection uses  the typical Windows color pallet for selection     al Background Color         DatarGraph Color Upon selecting the required parameter value    Plot Color press OK to confirm the selection  or press  Preview   Cancel to restore previous settings     Alternatively  press System button to reach the  OF  Cancel   System    Help    System Setup        Knife Edge Profiler Manual 53    a Projection    The Projection Window can be turned ON and OFF from the View menu  The keyboard shortcut       is F6  or click the Tool Bar button  The 3D image can be rotated  along the vertical and  horizontal axes using the  following routine    1  Place the mouse  cursor over the 3D image    2  Hold the left mouse  button down  note that the  mouse cursor shape has  changed    3  Drag the mouse while  pressing the left mouse  button  You can move the  cursor up down or left right   The image will rotate  accordingly          Centroidipm     x  201   Y ELEL     Diameter pm    W            Placing the mouse cursor over the Projection display and pressing t
13.   To print a text file     1  Select Print    from the File menu  Then select  Text file   A standard Windows file dialog  is displayed  Alternatively  press the keyboard buttons  Ctrl P     2  Select the  File Type  for the file to be printed     Contig    Plot files     pit     Chart files     cht   Text files    tet     x       3  The Knife Edge Profiler data files are located in the    Data    folder in the Knife Edge  Profiler directory  The Knife Edge Profiler directory is located in    Program Files    by  default     4  Click on the desired file from the file list on the left   5  Click OK   To print an Image file     1  Select Print    from the File menu  Then select  Image file   A standard Windows file  dialog is displayed  Alternatively  press the keyboard buttons  Ctrl l    Knife Edge Profiler Manual 32       3  There should be no need to change the directory  data files should be stored in the Knife   Edge Profiler directory   the default      4  Click on a file from the file list on the left     5  Click OK     Print Window    Print Window enables an immediate printing of the active window  The colored title bar indicates  the current active window   Print Window can be selected from the File menu  or the keyboard shortcut F12     A message box  Printing     is displayed when the window graphics is being transferred from the  program to the printer via the Windows Print Manager     To select and setup a specific printer select Print Setup from the File menu pri
14.   When Knife Edge Profiler is running and   am in another Windows application it runs slow   or appears to get interrupted   The Knife Edge Profiler must constantly collect and analyze data and may not work well  with all Windows applications  If you want to use another application while the Knife Edge  Profiler is running  select About from the Help menu  This will cause the Knife Edge  Profiler to pause it s data collection  With the About box on the screen  switch to the other  application     System Locks up during software startup  Treat this as a Hardware Failure  Review System Errors to resolve this conflict      F Because the program is locking up it may be impossible to change the software  setting to match the Interface board  In this case you will need to run the Windows  NOTEPAD application and open the Newport KEP Series CFG file in the Knife Edge  Profiler directory  The two hardware settings are stored in this file and can be edited to  match the desired values      Input past end of file  Error on startup    After pressing OK the Knife Edge Profiler application is    automatically closed  This error can occur when installing the  AN Meee esis tel ailte Knife Edge Profiler over the top of an old installation  Try  deleting the     ini file in the Knife Edge Profiler directory  Start  the application again           Analysis Errors  Analysis errors are associated with calculations and data collection     Small beam display on the Position Screen    The Position 
15.  Any change will be reflected in future printings     Newport Corporation  1791 Deere Avenue  Irvine  CA 92606  USA    P N 44762 01 Rev  A    Knife Edge Profiler Manual 3    Confidentiality  amp  Proprietary Rights    Reservation of Title     The Newport programs and all materials furnished or produced in connection with them      Related Materials     contain trade secrets of Newport and are for use only in the manner  expressly permitted  Newport claims and reserves all rights and benefits afforded under  law in the Programs provided by Newport Corporation     Newport shall retain full ownership of Intellectual Property Rights in and to all  development  process  align or assembly technologies developed and other derivative  work than may be developed by Newport  Customer shall not challenge  or cause any  third party to challenge the rights of Newport     Preservation of Secrecy and Confidentiality and Restrictions to Access     Customer shall protect the Newport Programs and Related Materials as trade secrets of  Newport  and shall devote its best effects to ensure that all its personnel protect the  Newport Programs as trade secrets of Newport Corporation  Customer shall not at any  time disclose Newport s trade secrets to any other person  firm  organization  or employee  than does not need  consistent with Customer   s right of use hereunder  to obtain access  to the Newport Programs and Related Materials  These restrictions shall not apply to  information  1  generall
16.  Edge Profiler software  The menus listed in the  Menu Bar contain items that allow specific actions to be performed  Sub menus or dialog boxes  may result from a menu item selection  These secondary items provide various controls of such  functions as graphics  analysis  configuration setup  etc     Tool Bar    The Tool Bar consists of various icon buttons  These buttons correspond to small symbols  providing quick access alternatives to using menus or keyboard equivalent commands  To use a  smart icon button  move the mouse cursor over the icon and click with the left mouse button  To  view the function of any icon button  place the cursor on the icon and wait momentarily  a brief  function description will appear near the icon     Window Area    The Window Area is utilized for the graphical display windows  The Knife Edge Profiler windows  can be arranged in any configuration  The Windows can show beam profiles  position diagrams   2D and 3D contours  charts and a power meter  Interactive mouse control of each window allows  a variety of customized configurations  The number of windows available in High Resolution  mode are restricted     Status Bar    The status bar is located at the bottom of the Knife Edge Profiler window  It indicates the current  status of key system measurement  configuration and operational parameters     Knife Edge Profiler Manual 23    Keyboard Operation    The keyboard can be used to enter text data entry or control most Knife Edge Profiler funct
17.  Found New  Hardware Wizard    This wizard helps you install a device driver for a  hardware device     To continue  click Het        i Cancel         Found New Hardware Wizard    Install Hardware Device Drivers a tae  A device driver is a software program that enables a hardware device to work with Sy    an operating system     This wizard will complete the installation for this device     oy Other PCI Bridge Device    A device diver is a software program that makes a hardware device work  Windows  needs driver files for pour new device  To locate driver files and complete the    installation click Next     What do vou want the wizard to do        Search for a suitable diver for my device recommended     Display a list of the known drivers for this device so that   can choose a specific    driver        Back Cancel         2  Insert the CD disk to the CD drive  Press Next button     Knife Edge Profiler Manual 18    Found New Hardware Wizard    Locate Driver Files a  Where do you want Windows to search for driwer files        Search for driver files for the following hardware device     z1 Other PCI Bridge Device    The wizard searches for suitable drivers in its driver database on your computer and in  any of the following optional search locations that you specify     To start the search  click Next  IF vou are searching on a floppy disk or CO ROM drive   inzert the floppy disk or CD before clicking Next     Optional search locations     Floppy disk drives    M CDROM drives
18.  Profiler software uses straight line interpolation to determine  transmission values for wavelengths that lie between wavelengths listed in the file     Absolute Power Calibration    A Filter file can be created to provide absolution power calibration  First measure the power of the  beam with a calibrated power meter  Then measure the reported power with the Knife Edge  Profiler Power Window  with the Filter option OFF  Now perform the following calculation and  use the   transmission value obtained when creating the Filter file       Transmission Value    Real Power   KEP Power    100    Creating a new Filter file  1  Select Create Filter File from the File menu     Create Filter File      Wavelength  nm  Transmission  4     Mo  roy f af 4    Next   Complete   Cancel   Help         2  There are 3 Value Entry boxes  each for line number  no    Wavelength  nm    Transmission value      The data box labeled as  No  starts with the line number value  of  1      3  Type a value for wavelength  or change it from the arrow keys of this data box  lf a  wavelength outside the operating range of the detector head is entered a warning will be  displayed     4  Type the percent transmission  or change it from the arrow keys if this data box     5  Press NEXT button to insert the next data line into the Filter file  The data box labeled as   No  will display the value of  2   go back and perform steps 3  4 and 5 until all the  desired wavelength transmission points have been entered   
19.  The  Chart Window graphically  7 displays the absolute position or   550 z   ii   ee width versus Time  the number  apsed time  1  Sec  Time  0 2  secidiv  of points accumulated  elapsed  time clock and the exact  Time Division scale increment  The setup button is used to set chart scaling and color options   The data can also be saved as a text file for external analysis      750 Pos             Chart Buttons       Pause  Click the Pause button to interrupt the data collection  The current data is not  lost when you use this function  When the Pause button is selected  it changes to a  continue button to resume data collection       Reset  Click the Reset button to clear the current data     Save  Click the Save button to save the current data up to the most recent 500 points  collected  The Save function automatically assigns a file name corresponding the current  date and time with a  CHT file extension  The data file will be located in the Knife Edge  Profiler data folder       Setup  Click the Setup button to access all of the Chart Setup parameters  The setup  parameters allow the user to set the data collection interval  vertical chart scale and  colors      F To get help on this window press F1 when it is the active Window  The Active  window is the window in the window area with the highlighted title bar     Reset  The Rest button is accessed from the Plot or Chart windows     The Reset option enables the user to reset all accumulated data for the Plot   Chart funct
20.  active     A gray menu item indicates that the item is currently unavailable  For example to start data  collection it has to be set up first     Low Resolution    Low Resolution is selected from the System menu  The keyboard shortcut for Low Resolution is  Ctrl L  or click on the Tool Bar button iin     The current resolution setting is displayed at the Status Bar and the Title Bar in the displayed  profile     In Low Resolution mode the system automatically normalizes the profile presentation to the peak  power intensity  The profile sample area is equal to 3 times the beam width at the 13 5  Clip  Level  The data is provided from about 500 sampled points at a rate of 5 Hz  The actual display  rate is dependent on computer configuration  See Speed Issues     The Low Resolution mode of operation enables the system to simultaneously display both profiles   V  amp  W   as well as Power and Position information     When more data points are required across a single axis use High Resolution  High Resolution  mode is utilized for beams less than 100um and non Gaussian beam structures     F When switching from High to Low Resolution all of the display windows will be  automatically closed  If any windows are open the current window configuration will be  lost     High Resolution   High Resolution is selected from the System menu  The keyboard shortcut for High Resolution is  Ctrl H  or click on the Tool Bar button all    The current resolution setting is displayed at the Status B
21.  automatically scaled  check the AutoRange  option   or held at a user specified value     When Auto Range is active the system continuously adjusts both the minimum and maximum  limits of the Plot  The Auto Range is designed to display the greatest amount of detail in the  window     When Auto Range is turned off  the system leaves the scale at the last auto scale setting and  manual control of the scale can be introduced  Use the Min and Max Value Entry Boxes for the  appropriate scale adjustment  When adjusting the Min and Max values avoid a situation where  large measurement fluctuations may go beyond the maximum and minimum vertical scale  The  Off Scale values will be displayed as flat lines at the top or bottom of the scale     Knife Edge Profiler Manual 59      Time Scale  The Time control allows the user to  specify the rate of data collection             Units  The unit selection control works in conjunction  with the Range selection for vertical scale selection         Units  fe mvt fe ui  Time   sec div 0 2       OF    Cancel   System      Help      Time Scale   The Time Scale is selected from the Plot Setup or Chart Setup dialog    The rate at which the Knife Edge Profiler software plots the data is controlled with this setting  Set  the desired Sec Div value with the Value Entry Box     The Time Scale will change the horizontal scale of the Strip Chart  The value can be changed in  one second increments  The fastest possible rate of display is 0 2 sec  which cor
22.  can be made  The resolution along the scanned profiles is very  high compared to camera systems  enabling resolution in  tenths of microns  instead of  tens of  microns  in a camera system  Consequently  they can measure beam widths down to several  microns  Their dynamic range is much larger than CCD camera systems enabling measurement  at relatively high power  They are unable to provide true representative 2D intensity contour plots  of the beam  They are unable to measure pulsed lasers but offers measuring capabilities at  wavelengths where the CCD cameras cannot work  utilizing sensors other than silicon     Knife Edge Profiler    The Knife Edge Profiler bridges the gap between CCD and scanning aperture beam diagnostics   The Knife Edge Profiler is based on Scanning Aperture technology so it has all the benefits of a  Scanning Aperture System  but it is enhanced with a patented multiple scanning knife edge  system  Unlike standard Scanning Aperture systems the seven scanning knife edges and a  mathematical process called  Reconstructive Tomography   provides 2D and 3D reconstructions  of CW laser beams  Because the Knife Edge Profiler uses knife edges as opposed to slits  it can  measure laser power  Knife Edge Profiler can measure beams up to 1 Watt with its ability to  insert filters behind the scanning knife edge thus prevent distortion of the beam measurement     Knife Edge Profiler Manual 14    Quick Start    To begin using the Knife Edge Profiler     Ez The warran
23.  can be made to accommodate other filters for absolute power calibration   See help for    Create Filter File    under the File menu     Running the Software  To run the software simply click on the Knife Edge Profiler Icon       In Windows system Click Start  select Programs and then choose Knife Edge Profiler     Several common symptoms result from an interface board conflict  If your symptoms match  one of those presented below  proceed to the suggested section  The possible symptoms  include   System Locks up during software startup   See    Operating Errors    to resolve conflict   Hardware failure    error in the toolbar   See    System Errors    to resolve conflict    If the Knife Edge Profiler software was working at one time and has now stopped working  try  reinstalling the interface board in a different expansion slot and see if that solves the problem   If it has no affect and no new software of any kind has been installed since the Knife Edge  Profiler last worked and the computer has not been moved  read    Contacting Newport    for  immediate support  It is unlikely that these instructions will help     Configuring Software  Before capturing data  configure the following settings in the software to insure a successful  first run of the Knife Edge Profiler     From the System menu select Hardware Setup     Verify the Plug in Address and IRQ settings     From the System menu select System Setup      Enter the wavelength of the test source    Choose an industry st
24.  is utilized to calculate beam diameter on the Chart Window etc   See    System Clip Level        Average     The displayed Average value corresponds to the number of samples averaged  before calculation and display  See    Average        Head Tilt     The Head Tilt value corresponds to the user entered value for the current detector  head azimuth rotation  See    HeadTilt        Run Step     The Run Step display indicates the current mode of data collection  If the screen  does not appear to update  verify that the system is not set to Step Mode  See    Run Mode        Resolution     The resolution display indicates the current acquisition mode  If you are not  able to display the 3D mode  check that the Status Bar is not indicating High Resolution  See     High Resolution    and    Low Resolution        Filter     The current filter selection is indicated     Power     The Power reading display is indicated   To Hide or Show the Status Bar  see     Status Bar Command        Status Bar Command    The Status Bar can be hidden or displayed by selecting Status Bar from the View menu or  using the keyboard shortcut Ctrl Insert     This option enables the user to toggle between Show Status Bar and Hide Status Bar     When Status Bar is active there is an additional line appearing at the bottom of the window   This line contains panels displaying general system information and user settings     Knife Edge Profiler Manual 27    Methods of Data Entry    Check box    To turn an optio
25.  more windows are active they will  overlap  The overlap results when the window size cannot be reduced to a level to fit the  available area     Tile Horizontal  This command will attempt to tile the open windows vertically along the left edge  of the window area  It works well with two open windows  When more windows are active  they will overlap  The overlap results when the window size cannot be reduced to a level to fit  the available area  Higher windows screen resolutions may help     Arrange Icons  When a window is minimized it is reduced to an icon representation and stacked  along the bottom of the window area  These Icons can be moved around with the mouse  To  return a nicely ordered group of icons along the bottom of the window area  select this  function  This is useful if the icon has been covered up with another window  Higher windows  screen resolutions may help     Knife Edge Profiler Manual 79    Help Menu    When a Help subject is displayed  additional help can be displayed by pressing the F1 key   The following commands and menu items are available from the Help Menu   File View Options Settings Windows   Help    Contents  Search For Help On    Ctrl F1  Active Window Fi    Newport on the Web     About Shift F1       The list of key combinations on the right side of the menu  indicate the corresponding keyboard  shortcut for that feature  These shortcuts may be activated from the Main Window by pressing the  keyboard combination     Contents  Press the F1 
26.  on the performance of the computer system and video card    When all of the desired parameters are set  click OK to confirm the selection  click Cancel to    Knife Edge Profiler Manual 56    return previous settings     Rotation Angle  Rotation is adjusted from the Projection Setup dialog     The Rotation function is used to change the viewing angle of the 3D projection  The rotation takes  place about the optic axis or azimuth of the 3D display  Rotation         Adjust the rotation angle with the Value Entry Box  The possible     Auto Flotate On Off values for the Rotation angle are 0 through 360 degrees  When  i   Auto Rotate is On the user can set Step increment between 1 and  gg UU ee is 30 degrees  The Auto Rotate function will rotate the 3D display  Rotate Angle     0   continuously at the user specified step increment  When Auto   Rotate is Off the user can set Rotation Angle to any desired value  between 0 through 360 degrees       gt  Place the mouse cursor over the currently displayed 3D Plot and hold the left mouse  button down  Drag the mouse cursor to display the 3D plot the desired rotation and tilt angle     The projection can be made to rotate automatically in 5 degree increments by selecting the Auto  check box     Projection Setup        Color Resolution  This options toggles    Settings eis el between a 16 Color and a 256 Color    Background Color   16 Colors     Upon completing the desired setup click OK    presentation       Data Color  to confirm the se
27.  provide additional audio  beeps when the specified limits have been exceeded     Alarm Limits  rv   Ww Onf W Sound        i  Min 1 000           Mas 19 000       Alarm Limits Options     On  Set Alarm Limits ON or OFF using the Check Box       Sound On  The Sound option is used for generating an audible warning in case the  measured power exceeds the preset Alarm Limits levels      Min  The Min option is used for setting the minimum range value for Alarm Limits    Knife Edge Profiler Manual 46      Max  The Max option is used for setting the maximum range value for Alarm Limits      gt  The minimum value set for Alarm Limits should be bigger equal the minimum value  set for Range  The maximum value set for Alarm Limits should be smaller equal the  maximum value set for Range     Sound On  Sound On is selected from the Power Setup dialog     Use this option to enable an audible warning when power drifts outside the pre set Max and Min  alarm limits  Toggle between Sound On and Sound Off using the Check Box     Max  Max is selected in the Power Setup dialog  The max setting is displayed in the    Range and  Limits    tab     The maximum setting corresponds to a user selected maximum power level  The Max setting in  the Range dialog section will set the maximum value displayed on the power scale  The Max  setting in the Alarm Limits dialog section will be displayed appropriately on the Power Window       gt  When the Alarm is active and the appropriate Min Max levels are set  t
28.  the Options menu  or the Tool Ba    A Log operation can be terminated early by activating Stop Log  If data collection is not stopped   the data collection operation will automatically end after the user specified Duration     The data collection will save data according to the parameters set through the Setup Log     Log Setup    The Data Collection Setup is selected from the Tool Bar Options menu     This setup window allows the user to  customize the Log operation  The  data collection rate and the data  filename can be entered from  Settings tab  Data can be saved  either to a Log file or Excel format  for further analysis       LogType    Select the desired file  type  Log file or Excel file  The Log  file is saved in a standard text format   The Excel file is saved as an Excel     CB eamnalizersD ata BeamAnalyzer log Workbook       File Name    Click the Browse    Browse      button to assign a File name and  location for the data file         LogT ype           Excel    File Hame    Note  When LOG file type was  selected  all data collected will be    OE    Cancel   Help    saved with the file extension   log     The  log extension designates the data as a text file and can be imported into other programs   When the Excel file type is selected the data will be saved as the file name   xls     Log settings    LogMode  This mode selection determines the method of data collection  The Time mode  selection allows data collection at a rate resulting from the interval and d
29.  the Tool Bar line disappears  In this case the user has to  activate the various system functions from the menu or keyboard shortcuts     Knife Edge Profiler Manual    64    Options Menu  The following items are available from the this Menu     File view   Options Settings Windows Help       Load Config File    Ctrlt c   Save Contig File    Ctrl 5 ae  eee   A check mark in front of a menu item indicates that the   Save Image as       function is active    Save Snapshot If a menu item is gray it means that item is currently   View Snapshot unavailable  A gray item indicates that additional conditions   Save Data in Text File       must be met for this item to be active  Review the manual  text associated with the gray item for required setup   Start Test         Sten i information  For example to start data collection the     i appropriate data collection setup parameters must be set    Server Mode   User Data   Close All Windows Ctrl     Save Settings an Exit       Load Configuration File    Load Configuration File can be selected from the File menu  The keyboard shortcut is    Ctrl O  or click the tool button    This option allows the user to load a configuration file containing the system setup  parameters  The configuration files have the extension   ini      To load a pre saved configuration file   1 Select Load Configuration File from the File menu     2  There is no need to change the  File Type  because  ini is the default    3  The Knife Edge Profiler data files are 
30.  um  0 1 um  width  gt   100 um  1 0 um    1 um   15 um    5 5   0 08 mm back from front surface of Head   0 5   0 18 mm back from internal front surface of  entrance hole     5 Hz  see Speed Issues   2 5 m long attached to the head    NG4  amp  NGQY  See filter files NG4 FLT  amp  NG9 FLT fora  Text format transmission table     We allow blade eccentricity of     15 um for the KEP 3     Knife Edge Profiler Manual    84    KEP 3 UV Detector Head    KEP 3    Entra  Pere lea       Front Y iew  Spectral Response    Number of knife edges  Sensor Input Aperture  Dimensions   Weight    Minimum Detectable Power    Maximum Power  633nm    Relative Power Measurement    Detector Type   Damage Threshold  Optical Dynamic Range  Beam Size Range  at 1 e    Beam Width Resolution    Beam Position Resolution  Beam Position Accuracy  Distance to Image Plane    Maximum Update Rate  Cable  Filters     Dimensions in mm        h 35 2 es  3 0    Thread  Side Yew  190 1100  3  5 mm Circular  35 2 mm  W  x 105 mm  H  x 87 5 mm  L     Hear View    22 OZ    10 uW   No filter  Power up to 5 mW  NG4 filter  Power up to 50 mW  NG9 filter  Power up to 1 W    0 1 uW resolution   UV Enhanced Si 10 10mm   200 W mm  with total power less than 5 mW at sensor  10 uW cm  to 10 W mm    no filter    5 mm to 3 um    width  lt  100 um  0 1 um  width  gt   100 um  1 0 um    1 um   15 um    5 5   0 08 mm back from front surface of Head   0 5   0 18 mm back from internal front surface of  entrance hole     5 Hz  see Spe
31.  values for Link transmission port are   1    COM 1  and  2   COM 2    3   COM 3  and  4   COM 4      F Choose a COM port that does not conflict with the  COM port being used        OF    Cancel   Help      Transmit    The transmit option is accessed from Link Setup  This setting should only be changed when  setting the RS 232 link communication     Transmit       File       The possible values for Link transmission port  are  File and Data   Selections are made with Radio Buttons   The Transmit setting is selected for either on line transmission of live Data or transmission of a    static pre saved text File  When Data is selected  the system will send the following data  depending on the active window     Low Resolution mode     Time  x x  Power  x xxx  PositionX  x x  PositionY  x x  WidthV  x x  WidthW  x x     WaveValue ClipLevel Average FilterName SystemNumber  For example     2 4 0 375 230 5 400 1 1234 4 2345 5 633 13 5 4 NG4 FLT 6715    High Resolution mode     Time  x x  Power  x xxx  WidthV_I Widhtv_Il WidthV_III WidthW_I WidthW_ll  WidthW_IlIl WaveValue ClipLevel_  ClipLevel_Il ClipLevel_lll Average FilterName  SystemNumber    For example  Profile V mode      2 4 0 375 1234 4 765 3 234 5 0 0 0 0 0 0 633 13 5 50 0 80 0 4 NG4 FLT 6715     F To stop a Link in progress  select Stop Link from the System Menu     Knife Edge Profiler Manual 37    Bits per second Baud Rate  The Bits per second Baud Rate setting is accessed from Link Setup     Bits per second   or Baud Rate
32.  while watching the change in Clip Level setting on  the profile presentation  The clip level can be moved vertically to a new clip level in 0 3   increments  When performing this operation it is helpful to size the Profile Window as large as  possible     Colors  The Colors selection tab will provide  the ability to set desired colors for the  Background  Plot and numerical data  A   G ai standard windows color pallet is available for      DataGraph Col    EE enti a color selection        Preview   LF al settings work independently in both the    W and the V profiles  Auto scale could be ON  OF    Cancel   System      Help      for one profile window and OFF in the other  profile window           Al w Profile    The W Profile Window can be turned ON and OFF from the View menu  The keyboard shortcut is    F4  or click the Tool Bar Button  A  Review the functions associated with the V profile Window for additional information     Knife Edge Profiler Manual 51       Position  The Position Window can be turned ON and OFF from the View menu  The keyboard shortcut is    at  F5  or click the Tool Bar button      es This window is not available in High Resolution mode     ley    Ae Tlopxy The Position function provides    a real time display of the beam  Centroid  pm  centroid position  as well as a  beam foot print  This window  can be used to align the  detector head with the  incoming laser beam  Settings  can also be customized by  clicking the Setup button     In the main windo
33. D Activex Control    Knife Edge Profiler Manual    93  93    95  95  96  96    97  98  99    100    10    E Introduction    Welcome to the Knife Edge Profiler          a mi ea   P    The Knife Edge Profiler is a beam  diagnostics measurement system for real time measurement and display of CW lasers  fiber optic  and laser diode beam profiles  The Knife Edge Profiler is designed to provide maximum flexibility   speed  and user friendliness for a variety of beam measurements  Measurements include  beam  width  shape  position  power  and intensity profiles  Some of the applications include  beam  alignment  on line monitoring  gaussian fit analysis  beam position measurement  laser beam  optimization and quality control     The Knife Edge Profiler Interface card and software can be integrated into a variety of compatible  PC computer platforms running under a Windows operating system  The Knife Edge Profiler  system will meet a wide range of automated laser analysis requirements in the laboratory  factory  and field     Theory of Operation    The Knife Edge Profiler measures beam intensity profiles  widths  position  power and the basic  beam shape of CW lasers  The detector head utilizes multiple knife edges to scan across the  beam and capture the intensity distribution of the laser     A simplification of a Knife Edge Profiler detector head is shown below          Attenuator    laser eam   i    Dasi    Enite Edge    Rotating Drum    The rotating drum contains multiple knife 
34. Log button requires setup  information to be available  The Step button will not be available unless the system is set in Step  Mode     Start Log  disabled     Step  disabled   so system is in RUN mode     Toggle Tool Buttons    The toggle group of tool buttons will turn display windows On and Off  These tool buttons act as a  toggle switch  When the corresponding window is active the button will appear to be pushed  down  When the corresponding window is not active the button appears in the UP position     M  Al w profile ON  F   W profile OFF    Hide the Tool Bar  See    Tool Bar Command        Date  amp  Time    The current Date and time is presented on the right side of the tool bar  System errors are also  displayed in the date and time location when necessary     Tool Bar Command    The Tool Bar can be hidden or shown by selecting Tool Bar from the View menu or using the  keyboard shortcut Shift Insert     This option enables the user to toggle between the Show Tool Bar and Hide Tool Bar     When the Tool Bar is selected there is an additional line on top of the window containing Tools   picture shortcuts to some of the most common used system functions  along with date time  information     When this option is not selected  the Tool Bar line disappears  In this case the user has to  activate the various system functions from the menu or keyboard shortcuts     Window Area    This area is utilized to display the graphical data windows  The Knife Edge Profiler windows ca
35. Review the list of available accessories for the addition of Head Tilt capability     Run Mode  This setting is accessed from the System Setup dialog     The Run Mode function is used to switch between a real time mode  Run  and a manually  activated mode  Step      po              In Run mode the window display is updated continuously in real time      3  In Step mode the last measurement is displayed and the window is frozen  A single new set  of measurements will be made only when a Step command is selected  The Step function is    selected by clicking the tool bar button or by pressing F9  A Step menu item is also available  in the Options menu  The Step function allows a detailed examination to be made on each profile  captured     Mode  f  Run Step    Toggle between these two options using the radio button  The mode selected is displayed on  the Status Bar     Beep    This setting is accessed from the System Setup dialog  The System Setup dialog can be  accessed from the System menu or by clicking on the current wavelength value in the status bar     The Beep option controls whether Knife Edge Profiler will produce the default system beep when  a Tool Bar error occurs  For example  when Beep is turned ON and the laser source is OFF  the   Low Power  Tool Bar error will be displayed while the system beeps     Knife Edge Profiler Manual 76    Beep    On Off    Select Beep using the Option box     Add Detector Head    The Add Detector Head function is selected from the Sys
36. System Clip Level  This setting is accessed from the System Setup dialog     The System Clip Level sets the clip level where most of the system calculations are performed   These calculations include  Beam Width  Gaussian Fit  and Elliptical measurements     Er A clip level defines the percentage of the peak intensity profile at which beam is  measured  For example  a clip level of 50  indicates that the beam is to be measured  at its full width at half maximum  FWHM   whereas a clip level of 13 5  measures the  beam at a point that is 13 5  of the peak of the profile  The 13 5  level corresponds to  the 1 e2 point of a Gaussian profile     In each Profile window Knife Edge Profiler displays the width of the beam at three clip levels  simultaneously  The clip levels appear in the profile window as solid lines that are superimposed  on the profile  The three clip levels can be changed in the Profile Setup dialog  The lowest clip  level is the typically the System Clip Level at 13 5      To change the System Clip Level    Clip Level  2    13 5        Select a value for the System Clip Level from the Value Entry Box  The selected value will be  displayed on the Status Bar     Average    The Average setting is accessed from the System Setup dialog  The System Setup dialog can  be accessed from the System Menu or by clicking on the current wavelength in the status bar     The Average function provides a successive averaging feature which smoothes the Position   Profile and Power d
37. To exercise this warranty  write or call your Newport office or representative  or  contact Newport headquarters in Irvine  California  You will be given prompt  assistance and return instructions  Send the product  freight prepaid  to the indicated  service facility  Repairs will be made and the instrument returned freight prepaid   Repaired products are warranted for the reminder of the original warranty period or  90 days  whichever first occurs     Limitation of Warranty    The above warranties do not apply to products which have been repaired or modified  without Newport   s written approval  or products subjected to unusual physical   thermal or electrical stress  improper installation  misuse  abuse  accident or  negligence in use  storage  transportation or handling  This warranty also does not  apply to fuses  batteries  or damage from battery leakage    THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES  EXPRESSED OR  IMPLIED  INCLUDING ANY IMPLIED WARRANTY OF MERCHNATABILITY OR  FITNESS FOR A PARTICULAR USE  NEWPORT CORPORATION SHALL NOT BE  LIABLE FOR ANY INDIRECT  SPECIAL  OR CONSEQUENTIAL DAMAGES  RESULTING FROM THE PURCHASE OR USE OF ITS PRODUCTS     First printing 2006       2006 by Newport Corporation  Irvine  CA  All rights reserved  No part of this  manual may be reproduced or copied without the prior written approval of Newport  Corporation    This manual has been provided for information only and product specifications are  subject to change without notice 
38. User Data enables the user to insert information required during the measurement session   The User Data string is limited to 60 characters   User Data can be selected from Options menu     User Data     Test SVSterm        OK    Cancel   Help         After inserting the user data information and pressing OK button  the information be displayed in  the Title Bar     Knife Edge Profiler Manual 71    Close All Windows  This function is selected from Options Menu  or by pressing the Ctrl W shortcut key   When this item is selected  all open windows are closed     Save Settings on Exit  Save Settings on Exit is found in the Options menu     This option allows the user to save the current software settings in a default configuration file       ini   When the software is started it will automatically load this saved configuration file     A check mark in front of the Save Settings on Exit menu item indicates that this function is active   The default setting is enabled     Knife Edge Profiler Manual 72    Settings Menu  The following commands and menu items are available from this Menu     File View Options   Settings Windows Help  w  Low Resolution CErl  L  High Resolution Ctrl  H    System Setup    Add Detector Head Chri D       The available keyboard shortcuts are displayed on the right side of the menu  These shortcuts  may be activated from the Main Window by pressing the corresponding keyboard combination     A check mark in front of a menu item indicates that the function Is
39. a particular    computer will be influenced by a variety of factors  CPU Speed  Computer RAM  Video Card   Video RAM  Screen resolution  Screen color depth and Operating System being used     Benchmark data has been compiled form two different computer systems  System  A  is a  Pentium Ill 450MHz 64 Megabytes Windows Me Screen resolution 768x1024x16bit  AGP card    with 4 Megabyte  machine     Computer System     One  Two  Two  Two  Two  All    Prot    Profiles   Profiles Power  profiles Position  profiles Positiont Power  screens without 3D    3D OnLy  2D Only    All  All    screens with 3D  screens with 2D    Knife Edge Profiler Manual    NAD ING ISD i  Or    Qa UO UA    O O1 O1 O1    94       Troubleshooting    The following sections will list common problems and probable solutions     F After reading these sections and the relevant portions of the help system  you may still have  a question  Please refer to Customer Support     Error Categories   System Errors   Displayed on the right hand of the tool bar   Operating Errors   Error messages or lock ups  Analysis Errors   Results or plots that do not appear correct     System Errors    Low power    System Errors are displayed on the right hand side of the tool bar     They indicate a problem with the hardware or detector head  When these errors are displayed all  results are removed from the window      Low power     This message means that insufficient light is available on the detector  This error will occur if less  tha
40. allation for Windows 98  Me  2000  XP  Installation for Windows NT4 0  Software Installation  Connecting the Detector  Selecting a Filter  Running the Software  Configuring Software     amp  Operation  Title Bar  Menu Bar  Tool Bar  Window Area  Status Bar  Keyboard Operation  Tool Bar  Window Area  Status Bar  Methods of Data Entry  Selecting a check box  Radio Button  Using the Value Entry Box  Colors    Knife Edge Profiler Manual    11  11  11  13  14  15    15     amp  Menus and Commands  File menu    View File  Create Filter File    Print       Print Text File  Print Image File    Print Window  Print Screen  Print Setup    Start Log  Stop Log          Log Setup  Start Stop Link    Link Setup  Port  Transmit  Bits per second  Parity Bit  Data Bit  Stop Bit  Slave Mode  Making a Null Modem Cable    Exit    View menu    Power    Filter   Null   Power Setup  Units   Power Display  Power Range  Alarm Limits  Sound On  Max   Min       Al v Profile    Gaussian  Profile Zoom  Profile Setup  Auto scale  Clip Levels  Profile Grid    Knife Edge Profiler Manual    A  W Profile  fH Position    Position Setup  Position Zoom  Position Grid        Projection  Projection Setup  Projection Grid  Axes  Dimension  3D Features Setup  Rotation Angle    Plot Power    Reset  Save Plot  Plot Setup  Plot Range  Time Scale  Units Plot        Chart Width Position  Reset  Save Chart  Chart Setup  Chart Range    Status Bar Command  Tool Bar Command     e menu  Load Configuration File    Save Configur
41. and a set of data points from a beam profile  P   as  shown below     Knife Edge Profiler Manual 92    Data Points  P  ata Points  P  Gaussian Curve  G        Intensity    Lose    0 j N          Each data set is composed of points for j   0  1  2      N  The correlation coefficient is derived from  the following steps     1  S  the Integration of the squared differences between the two curves is found   S   Integral   P G     2  The deformation at each point from the average  Dj  is then determined   So   Integral   G     3  The fit coefficient  C  is a percentage defined with the following formula     C   100    1    SQRT  3 S So      Ellipticity    Elliptical measurements are calculated utilizing data from 3 blades  The actual calculation is in  accordance with standard formulas for ellipse calculations utilizing 3 chords     1  The major and minor axes of the fit are calculated by determining the distance from the  centroid to the ellipse     2  Orientation  Theta 8  is a measure of the orientation of the major axes  Theta is  measured from the positive X axis and varies between  90   and  90       Speed Issues    The motor speed limits the maximum update rate to 5 Hz  The software can acquire data at 5 Hz  by starting a Log file when all graphic screens are closed     Knife Edge Profiler Manual 93    When several windows are opened the system may slow down  especially when using the 3D    feature  High performance computers can display the data faster  The update rate of 
42. andard Clip level  13 5  or 50     You may increase averaging if values vary more than desired   Select High resolution if beam is  lt  100 um    Run mode captures continuously and is best for general operation  Step mode captures  data when a user clicks a button                Knife Edge Profiler Manual 22     amp   Operation    This section covers the basic layout of the Knife Edge Profiler software     When the Knife Edge Profiler application is started  the main Knife Edge Profiler window appears   The Knife Edge Profiler window consists of display and control elements similar to most Windows  applications along with elements specific to Knife Edge Profiler interface     The main elements of the Knife Edge Profiler window interface are as follows     So Newport KEP 7 SL S N  715 Tithe Bar  File View Options Settings Windows Help Kdenu Bar    oli  SS F  afl  IE PALALBIE S  ex  ie  tel 2  Toolbar Icon               Wavelength  623rm   Clip Level  13 5    Average  OFF   HeadT ilk O     Run tatus Bar  Title Bar    The Title Bar displays the name   Newport KEP  followed by the detector head type and serial  number  The Windows operating system provides special controls in the title bar of a window   From the title bar the main window can be closed  moved  sized  minimized to icon form or  maximized to fill the screen  For more information on these controls see the Windows manual or  find the Windows Tour program     Menu Bar    The Menu Bar lists menus available for the Knife
43. anual 28    Colors    The color option enables the user to set the background color  data color and plot colors for the  various windows  Select the desired color from the standard Windows color pallet  Custom colors  are also available with the appropriate video card and Windows color setting     The Position and Profiles window will allow the selection background color  data color and plot  color  The Power and Projection windows allow for the selection of background and data color  In  Plot and Chart windows allow for the selection of background and plot color     Knife Edge Profiler Manual 29     amp  Menus and Commands    The following Command Menus are available on the Knife Edge Profiler Menu Bar     File View Options Settings Windows Help    File Menu    The File menu allows the user to perform many file operations  The following commands and  menu items are available from this Menu       File View Options Settings Windows Help    View File    Crrl   V  Create Filter File    Ctrl F Note that the keyboard shortcuts are listed to the  oe    right of the feature  These shortcuts may be  Print Window Fiz activated from the Main Window by pressing the  Print Screen Ctri F12 appropriate keyboard combination   Print Setup     Start Log Chr  Log Setup  Start Link  Ctrl k  Link Setup     Slave Mode Ctrl M  Esbon Ctrl              View File       View File can be selected from the File menu  The keyboard shortcut is Ctrl V  or click the tool    button     This option provides t
44. aphical presentation only without the measurement data  display on the right hand side of the window    Placing the mouse cursor over the Position display and pressing the mouse left hand button twice  changes the modified position window back to its original size and shape     F These values are merely estimates and are less accurate than width  measurements made in the Profiles functions      F To get help on this window press F1 when the Window is active  The Active  window is the window with the highlighted title bar     Knife Edge Profiler Manual 52    Position Setup    The Position Setup is selected from the Position window      _   Zoom  The Zoom selection  or E activates the zooming capability of  ian the position display  Small beams  a are enlarged and centered on the  plot     Grid  The Grid selection enables a  grid pattern on the position display   Finke   Digital  The Digital selection  we displays the position data as a digital  display only         View  J    Zoom  W Grid       OK   Cancel   System      Help      Position Zoom  The Position Zoom is adjusted from the Position Setup window     The Position Zoom is used to view the footprint of small beams more clearly  It is recommended  that this option be activated for beam widths of less than 300u  Once activated  the area  immediately surrounding the beam is magnified to show the footprint in the greatest possible  detail  The size of this region is automatically scaled up or down as the beam changes size   
45. ar     High Resolution mode automatically locates the profile and the hardware samples the beam and  vicinity utilizing 8000 points  Typically 4 points out of the 8000 points are filtered to create one  point  Typically the resulting profile would include about 2000 points  When the beam is large    9  mm  all points are utilized for the beam profile  When the beam is smaller  the system  automatically locates the beam and samples the surrounding area with a typical resolution of  about 2000 points  The beam and the surrounding area can be 6 times larger than the beam size  at the 13 5  clip level     Knife Edge Profiler Manual 73    The High Resolution profile displays typically 2   3 times better resolution than Low Resolution  mode  Maximum resolution is physically limited to 0 1 micron     The High Resolution function is especially effective when dealing with beams that are far from  Gaussian in shape or smaller than 100 microns     High Resolution mode utilizes all of the on board memory  total of 8K  for sampling one profile   This memory limitation allows the system to display one High Resolution profile at a time  The  Position and Projection windows are not supported in High Resolution mode     Ej When switching from High to Low Resolution all of the display windows are  automatically closed  If any windows are open the current window configuration will be  lost     System Setup    System Setup can be accessed with the System button in each operation window or from t
46. ation File  Configuration File Contents   Save Image as      Save Snapshot   View Snapshot    Save Data in Text file     Importing Files into Excel    Start Stop Test  Test Setup   Step   a Server Mode   User Data    Close All Windows  Save Settings on Exit    Knife Edge Profiler Manual    65  65    66  66  66  67  67  67  67    69  70    70    70  71  72  72    Settings menu  Low Resolution  High Resolution    System Setup  Wavelength  System Clip Level  Average  Head Tilt  Run Mode  Beep   Add Detector Head  New connections  Add Calibration Files    Window menu    Help menu  Contents   Search for Help On  Active Window  Newport on the Web     About    E Hardware  KEP 3 IR Detector Head  KEP 3 SL Detector Head  KEP 3 UV Detector Head  KEP 7 IR Detector Head  KEP 7 SL Detector Head  KEP 7 UV Detector Head  Interface Board     amp   Calculations Summary  Accuracy   Background Noise   Relative Total Power   Beam Width   Beam Centroid Location    Gaussian Fit  Gaussian Fit Diameter  Gaussian Correlation Coefficient    Knife Edge Profiler Manual    73  73  73  74    75  75  76  76  76  T7    78    79    80  80  80  80  81  81    82  83  84  85  86  87  88  89    90  90  90  91  91  91  92    92  92    Ellipticity  Speed Issues     amp  Troubleshooting    System Errors  Operating Errors  Analysis Errors     amp  Knife Edge Profiler Head Accessories  amp  Drawings  Knife Edge Profiler Rotation Mount   Fiber Adapter   Knife Edge Profiler Head types and their internal dimensions    S
47. constrains     We allow blade eccentricity of    30 um for the KEP 7       Optional  InGaAs 5mm diameter detector is also available  model KEP 7 IR5     This head conforms to all applicable CE Mark standards     Knife Edge Profiler Manual    86    KEP 7 SL Detector Head       Dimensbns inmin     KEP 7  13 13 1    p       4       Entrance  Apera lure    S 525    50 D 105       Tread  35 2   L s   Front Y iew Side Yew Hear Y iew  Spectral Response 350 1100  Number of knife edges 7    Sensor Input Aperture  Dimensions  Weight    Minimum Detectable Power  Relative Power Measurement    Maximum Power  633nm    Power Measurement  Accuracy    Damage Threshold  Optical Dynamic Range  Beam Size Range  at 1 e    Beam Width Resolution    Beam Position Resolution  Beam Position Accuracy  Distance to Image Plane    Maximum Update Rate  Cable  Filters    9 mm Square   35 2 mm  W  x 105 mm  H  x 87 mm  L   22 OZ    10 uW   0 1 uW resolution    No filter  Power up to 5 mW   gt 0 1 mm diam   NG4 filter  Power up to 50 mW   NG9 filter  Power up to 1 W    5     200 W mm  with total power less than 5 mW at sensor  10 uW cm  to 10 W mm    no filter   9 mm to 15 um    width  lt  100 um  0 1 um  width  gt   100 um  1 0 um    1 um   15 um    3 5   0 08 mm back from front surface of Head   0 7   0 18 mm back from internal front surface of  entrance hole     5 Hz  see Speed Issues   2 5 m long attached to the head    NG4  amp  NGQY  See filter files NG4 FLT  amp  NG9 FLT fora  Text format transmission 
48. d     Bits per second    9600     Data bits  le    r    The possible values are 1 or 2     This setting must match the same setting on the receiving  computer     Parity Bits   None     Stop bits           2       Knife Edge Profiler Manual 39    Slave Mode    After selecting the Link Setup parameters the user can activate the Slave Mode option from the  System menu  The keyboard shortcut for Slave Mode is Ctrl M  Transmit parameter should be  selected as Data     W Lom Resolution Chrl L  High Resolution Ctrl H  System Setup    Add Detector Head Ctrl D    Start Lirik  Cirl k   Link  Setup       Slave Mode Ctrl       After selecting the Slave Mode option  a status window will be displayed in the upper left hand  corner of the Windows area     Slave Mode in progress      In order to receive transmitted data on the master computer it is necessary to press button    d    on  the keyboard or send the Knife Edge Profiler program an ASCII code for    d     To terminate Slave  Mode it is necessary to unselect this option in System menu  terminate the Slave Mode from  Knife Edge Profiler program end   The user can terminate Slave Mode from the master computer  by pressing the button    s      or sending the slave computer an ASCII code    s        The receiving program at the master computer is not provided with the Knife Edge Profiler  product  It should be written according to the user   s application needs     Making a Null Modem Cable  A null modem cable can be made from a standar
49. d RS 232 cable by connecting the pins on one  end of the cable to the pins on the other end as shown below     Null modem with 25 pins on both sides     5 Pin Side    25 pin side     ce nn ae oc  Tt 2 2 TE  RTS 4 4 RTS  CTS 5   CTS  SG 7 el SF ce  DSR 6 6 DSR  pcb 8 Sc DCO  DTR 20 20 OTR    Knife Edge Profiler Manual 40    Null modem with 9 pins on one side and 25 pins on the other side    9 Pin Side    25 pin side     DCO 41      1 Unused  FG   RO Fi 2 TO   T   3 3 RO   OTR 4 4 RIS   SG 5 Iono   DSE 6 6 DSR   RTS F f SG   CTS 6 6 OCD   F     9     20 OTR    Null modem with 9 pins on both sides    9 Pin Side    9 pin side     DED 41 1 DCD   Ro 2 2 RD   TO 3 3 TO   DTR 4 4 DTR   SG 5 5 SG   DSR 6b 6 DSR  RTS  f E fF RIS  CTS    8 CTS    Ri 9          9 Unused  Ri   Exit    The Exit function is selected from the File menu  The keyboard shortcut is Ctrl X   Use this option to terminate the Knife Edge Profiler application     The following dialog is shown when you exit the program and Save Settings on Exit is not  enabled  It is a reminder to save the current setup parameters     oe  Newport J x     AN Current user settings will not be saved when the program exits  Save current user settings        Select Yes to exit and save current user settings     Knife Edge Profiler Manual 41    View Menu    The View menu operates the functional windows  The following commands and menu items are  available     File   View Options Settings Windows Help               Power Fe  Profile w F3  Pr
50. data display on  the right hand side of the window     Knife Edge Profiler Manual 42    Placing the mouse cursor over the Power display and pressing the mouse left hand button twice  changes the modified position window back to its original size and shape     The power units can be selected by clicking on the units displayed in the Power Window  Each  mouse click will cycle to the next unit  UW  mW and dBm      Power Buttons     Null  The Null button will Activate or deactivate the ambient light suppression     Filter  The Filter button will Load or unload a pre defined filter transmission file for power  calculations       Power Setup  The Setup button will display the Power Setup dialog containing various  power related settings     F To get help on this window press F1 when Window is active  The Active window is  the window with the highlighted title bar     Filter  The Filter button is accessed from the Power window      amp  This button is not available when Knife Edge Profiler is used with the InGaAs or  detector head     Because silicon detectors can saturate very easily  it is frequently necessary to insert a filter in  front of the detector  The filter will attenuate the beam and prevent saturation  Since the  wavelength response of the filter is not flat  it is necessary to install the transmission properties of  the filter in the software to obtain a proper power measurement  The proper gain settings for the  detector amplifier are also determined by the actual sen
51. dge Profiler Manual 91    Where   w   location along W axis  p w    intensity at location w on W axis  I   total intensity of W profile   W   center position of W axis     Simple axis translation is then used to present the data in X Y coordinates     The affect of background ambient light    The profiles are obtained by performing a derivation on the digitized power curve  Ambient light is  suppressed since it is constant over the detector surface resulting in a derivative of zero   However  if a low power large area beam is examined  then it is very important to suppress  background illumination as much as possible     Gaussian Fit    The Gaussian Fit is a least squares fit of a Gaussian equation to the cross section beam profiles   The correlation coefficient is the normalized sum of the fit residuals     The following equation is used to determine the Gaussian Fit   I   Ve    x c  of   where I   the intensity of a pixel at location x   In performing a least squares fit to this equation  the following terms are derived   V   the maximum intensity of the fitted Gaussian curve  Peak Intensity    C   the center of the Gaussian fit peak  Centroid    o   the radius of the Gaussian fit curve at the 1 e2 intensity level  Diameter      Gaussian Fit Diameter  The Gaussian Diameter is the width of the Gaussian fit at the clip level specified     Gaussian Correlation Coefficient  The Gaussian correlation coefficient is calculated as follows     Given a theoretical Gaussian curve  G  
52. e  levels  80   50   amp 13 5   of the Clip Levels may    CE   be changed using the    Setup button  The third    __Setup   clip level  13 5   is the    System Clip level and it     Hm        can be modified from System Setup in the System menu     Placing the mouse cursor over the Profile display and pressing the mouse left hand button twice  changes the position window to a graphical presentation without the measurement data display   Placing the mouse cursor over the Profile display and pressing the mouse left hand button twice  changes the modified position window back to its original size and shape     Profile Buttons     Gaussian The Gaussian selection compares the displayed profile to an ideal Gaussian in    Knife Edge Profiler Manual 48    real time       Zoom The Zoom selection is available only in High Resolution mode  The Zoom function  increases or reduces the displayed X Axis range   spatial resolution  The profile peak will  remain centered on the display when the Zoom is changed       Setup The Setup selection provides access to the profile settings including  background  color  grid lines  auto scaling of the profile peak and clip level adjustment      F To get help on this window press F1 when the Window is active  The Active  window is designated with the highlighted title bar     Gaussian  The Gaussian button is selected from the Profile window     This function determines how closely the measured beam profile matches a theoretical Gaussian  profile  When t
53. ed Issues   2 5 m long attached to the head    NG4  amp  NG9 can be used for the range 400 1100nm   See filter files NG4 FLT  amp  NG9 FLT for a Text format  transmission table     We allow blade eccentricity of     15 um for the KEP 3     Knife Edge Profiler Manual    85    KEP 7 IR Detector Head    KEP      Entrance  Apera lure    T    k 52 5  50 D 105    eu hdd  Thread      35 24        35    Front Y iew  Spectral Response    Number of knife edges  Sensor Input Aperture  Dimensions   Weight    Minimum Detectable Power    Relative Power Measurement    Maximum Power    Power Measurement  Accuracy    Damage Threshold  Optical Dynamic Range  Beam Size Range  at 1 e    Beam Width Resolution    Beam Position Resolution  Beam Position Accuracy  Distance to Image Plane    Maximum Update Rate  Cable    Filters     Dimensbns inmin   13 1        a H       Ma  Thread  Side Yew Hear View  800 1800  calibrated range  800 1720nm  7    9 mm Square  active area    3    35 2 mm  W  x 105 mm  H  x 87 mm  L   22 OZ    10 uW   0 1 uW resolution   Power up to 5 mW  50 1 mm diam      10     200 W mm  with total power less than 5 mW at sensor  10 uW cm  to 10 W mm    no filter   3 mm to 10 um    width  lt  100 um  0 1 um  width  gt   100 um  1 0 um    1 um   15 um    5 5   0 08 mm back from front surface of Head   0 5   0 18 mm back from internal front surface of  entrance hole     5 Hz  see Speed Issues   2 5 m long attached to the head    The InGaAs head does not use filters due to mechanical  
54. ed for    Knife Edge Profiler Manual 13    swapping the filters  a filter blank for 100  transmission and filter transmission data     Mounting Post    The mounting post is 105 mm long with an M4 thread  The post is utilized for mounting the  detector head     Knife Edge Profiler and Beam Diagnostics    Two general types of instruments measure laser beam intensity  The following paragraphs  explain the strengths and weaknesses of both measurement techniques  The Knife Edge Profiler  bridges the gap between these techniques     CCD Array Camera Diagnostics    CCD array camera based diagnostics use an array of sensor pixels to measure the intensity over  the face of the entire laser beam simultaneously  This allows them to capture data from pulsed  lasers and display the data in 2D contour plots and 3D views  The pixels are of finite size  8   12  um  and the smallest measurable beam size is typically 40 times larger than the pixel  CCD  camera based diagnostics are very sensitive and require high optical density laser grade filters to  prevent saturation and beam distortion  In some cases  this is not desirable or practical     Scanning Aperture Diagnostics    Scanning Aperture Diagnostics operate with either knife edges or slits  The knife edge method is  described in    Theory of Operation     The Slit method is similar but uses a very narrow slit instead  of a knife edge  These systems usually obtain one or two high resolution beam profiles from  which accurate measurements
55. edge  apertures   only one is shown in this diagram   As an aperture passes between the laser beam  and the stationary power sensor  there is a period where the entire beam is allowed to reach the  sensor  At this point  the Knife Edge Profiler can measure the total power of the beam  As the  aperture is scanned across the beam  the knife edge blocks off an increasingly larger portion of  the beam power  The power sensor measures this change in power versus knife edge position  creating a power vs position plot as shown below     Knife Edge Profiler Manual 11    Measured Power as knife edge cuts the beam    Power      Change in measured    ri power with position     Knife Edge Position    The analog power reading is digitized with a high speed A D  Analog to Digital  converter  At the  same time the exact position of the knife edge is monitored so that beam width information can  be determined  The beam profile for each knife edge is then obtained in software by taking the  derivative of the measured power curve  The beam profile is perpendicular to the knife edge and  each point of the profile is the sum of all intensities along the axis of the knife edge at that knife   edge position  The digitized beam profiles are then stored in memory        Knife Edge  ee    The Knife Edge Profiler obtains profiles from multiple knife edges at different orientations and has  the ability to use this information to create 2D and 3D plots of the beam  The mathematical  reconstruction proce
56. elp menu will start the default browser and connect to the  http   www newport com     Knife Edge Profiler Manual 80    About  The About box is selected from the Help menu     The About screen provides the current software version  detector head serial number  Newport  contact information  and Copyrights  The OK button will clear the About information from the  screen     Knife Edge Profiler Manual    81     amp  Hardware    The Knife Edge Profiler uses an interface board to digitize the incoming video signal  This chapter  covers the various technical specifications for the supplied detector heads and the interface card   There are six detector head options available for the Knife Edge Profiler  The following topics are  detailed specifications for each detector     Note  All heads conform to all applicable CE Mark standards     Knife Edge Profiler Manual 82    KEP 3 IR Detector Head    KEP 3  has H    13 1    Entra  plutei       e      Front Y iew    Spectral Response  Number of knife edges  Sensor Input Aperture  Dimensions   Weight    Minimum Detectable Power    Maximum Power    Relative Power Measurement    Power Measurement  Accuracy    Damage Threshold  Optical Dynamic Range  Beam Size Range  at 1 e    Beam Width Resolution    Beam Position Resolution  Beam Position Accuracy  Distance to Image Plane    Maximum Update Rate  Cable  Filters     Dimensions in mm     13 1       L 35 24 ee  3 0    Thread  Side View  800 1800    Hear View    3   5 mm Circular  active area   3
57. er computer can receive the  data using a program that can communicate over a COM port like the Windows HyperTerminal  program     To transmit a file over RS 232   1  Connect the Knife Edge Profiler system to another computer using a null modem cable   See Making a Null Modem Cable   2  Before using Start Link  set the Link parameters in Link Setup  Each link parameter must  be configured to match the communications protocol of both computers receiving data   3  Enable the receiving program to receive the data     4  Select Start Link from the System Menu  A standard Windows File box is displayed   5  Select the  File Type  for the file to be sent     Config files    Plot files     pit     Chart files     cht   Text files    tet     x       Knife Edge Profiler Manual 35    6  There should be no need to change the directory because most files should be stored in  the Knife Edge Profiler directory     7  Click on a file from the file list on the left     8  Click OK  A link status will be displayed in the upper left hand corner of the Window area        The file is transmitted in the Background while Knife Edge Profiler continues to capture  data  When finished the Linking status message will disappear  To stop a Link in  progress  select Stop Link from the System menu     Link Setup    Link Setup is selected from the System Menu  The keyboard shortcut for Link Setup is Ctrl K     The Link Setup allows the user to configure the system for a particular set of parameters needed  
58. f the image  window     Save Data in Text file     Save Data in Text file is selected from the File menu     The Save Data file function is used to save the profiles or projection data displayed  The default  file extension is   txt  The data is saved in a text file format for analysis with other programs     Knife Edge Profiler Manual 67    Ei Profile Snapshots cannot be loaded back into the Knife Edge Profiler software     To save a profile Snapshot   1  Select Save Snapshot File from the File menu     There is no need to change the  File Type  because  snp is the default     3  The Knife Edge Profiler data files are located in the    Data    folder in the Knife Edge  Profiler directory  The Knife Edge Profiler directory is located in    Program Files    by  default     4  Type a filename in the box below the word  File name   The  snp file extension will  automatically be attached during the saving process     5  Click OK     Importing Files into Excel    All of the Knife Edge Profiler files are stored in ASCII file format for easy printing  viewing and  analysis  Loading any of data files directly into Excel will activate the import wizard  A  fixed  width  or  space delineated  file format works best when using the import wizard     This graph was created in less than 5 minutes by importing a snapshot file into Excel     Profiles  25000    20000  15000    10000    points    2000        5000    Intensity    Knife Edge Profiler Manual 68    Start Stop Test    Start Test  o
59. for the RS 232 transmission  The default values are typical for this kind of transmission  are    shown below     Link Setup    COM fi      Transmit  C File i Data    OF    Cancel   Help      Link Setup    Bits per second    9600    Data bits  le      Parity Bits   None     Stop bits  fi       OF    Cancel   Help      Knife Edge Profiler Manual                 Port  The COM port setting selects the port utilized for  RS 232 transmission from the Knife Edge Profiler based  computer       Transmit  The Transmit radio button selection toggles  the transmission type between transmit a file or real time  data     Set RS 232 serial parameters       Bits per second  The Bits per second selection  determines the transmission rate  baud rate  of the data  transmission       Parity Bit  The Parity Bit selection determines the  Parity Bit utilized for robust serial communication       Data Bit  The Data Bit selection determines the  number of data bits utilized for transmission       Stop Bit  The Stop Bit selection determines the  number of stop bits utilized for transmission     Press OK to confirm the selection or CANCEL to restore  previous settings     36    Port    The Port selection option is accessed from Link Setup  This setting should only be changed  when utilizing the RS 232 link communications   The Port setting is utilized to set the computer communication  COM  port for RS 232 data    Link Setup x     General   Fort Setti PO     Port Setings  transmission     The possible
60. ge Profiler data files are located in the    Data    folder in the Knife Edge  Profiler directory  The Knife Edge Profiler directory is located in    Program Files    by  default     4  Type a filename for the configuration file in the box below the word  File name   The file  saving process will automatically attach the  ini file extension     5  Click OK  The configuration file can now be loaded at any time using Load  Configuration File command in the File menu     Automatic Configuration    To have the Knife Edge Profiler automatically save the current configuration each time Knife   Edge Profiler software exits  select Save Settings on Exit from the Option menu  When this  option is enabled  the Knife Edge Profiler software will store the current configuration into the  default configuration file   S   ini   When the Knife Edge Profiler software starts again it will  automatically load the      ini file     Configuration File Contents   The following information is stored in a Configuration  INI  file     System serial number   System resolution   High Low    System wavelength setting   System clip level setting   Setting for averaging   Setting for headtilt   Setting for system beep   Active windows size  amp  position   Setup parameters for each window   Test setup parameters                         F The configuration file does not include hardware settings  If the hardware settings are  changed  the previously stored configuration files will work  The  System I O add
61. h resolution 2D       An example of Medium Wire Density 3D       3D Features Setup    Projection Setup           Rotation  The Rotation function affects  the optical axis or azimuth of the 3D display  Adjust the viewing angle using the Value  Entry Box  The possible values for the  Rotation Angle are 0 through 360  degrees  The Rotate Angle value can only  be changed when the Auto Rotate box is  not selected  The projection can be made  to rotate automatically with a selected step     ea   Wire density  RotateAngie        0   li   Meche wt ek  interval by utilizing the Auto Rotate Check    OF    Cancel   System      Hel    Box  When the Auto Rotate box is    selected the step increment can be set to the desired value      Tilt     The Tilt function selects the tilt angle of the 3D plot  The 3D plot can be viewed at  horizontal tilt angles form O to 90 degrees in 1degree increments  The horizontal tilt angle can be  entered with Value Entry Box     Rotation Tilt     Auto Rotate On Off Horizontal Tit        45      Step H   in H       F Free adjustment of rotation and tilt angle is accomplished by placing the cursor over the  graphical 3D display while holding the left mouse button down  Movement with the left mouse  button down will adjust the tilt and rotation simultaneously       Wire density     The wire density selection determines the number of wires utilized to construct  the 3D plot  The high density setting can affect the update rate of the displayed 3D profile  based 
62. he  System menu  The System Setup can also be accessed by double clicking the current  Wavelength display in the status bar  System Setup allows Knife Edge Profiler to be configured  to suit a particular set of test needs     System Setup E     Settings      Operational modes of the system     Wavelength  nm  HeadTilt     Wavelength    2    630 mm   30 a Clip Level    Average    Clip Level  72  Mode    125      Aun      Step Head Tilt  Mode  Average Beep Beep  M oot   2 4 M Onni       The current System Setup parameters are displayed in the Status Bar   Confirm the settings by clicking OK button or restore the previous settings with the Cancel button     Wavelength    This setting is accessed from the System Setup dialog  The Wavelength value is utilized to  calculate the current Power Reading     Wavelength should be set to match the laser source  Knife Edge Profiler detectors have response  curves that are dependent on the wavelength  These response curves have been corrected within  the calibration file  Therefore it is important to enter the correct wavelength to obtain a correct  power measurement     Knife Edge Profiler Manual 74    Wavelength  rim   B30    The wavelength can be entered in 1 nanometer increments from    the Value Entry Box  The current wavelength value will be displayed in the Status Bar     Possible values for wavelengths are     190   1100 nm for the silicon UV version   400   1100 nm for the silicon version   800   1800 nm for the InGaAs version     
63. he Gaussian button is activated  a Gaussian profile is overlaid on top of the current  measured profile in real time  The gaussian fit profile is in red  The percent correlation and width  comparisons utilize the currently selected clip levels  The comparison data is displayed adjacent  to the profile data  The comparison data includes data about the ideal Gaussian profile beam  width as well as the deformation from the ideal Gaussian beam     Fil Profile     Jol x     Relative Intensity   ee To turn Gaussian Off press the  correlation  4  Gaussian button again     Frot  Gauss        Profile Zoom  Profile Zoom buttons are selected from the Profile windows     This option allows the displayed X axis range  spatial resolution  High Resolution Profile  to  Zoom In or Zoom Out  by a factor of two  The Knife Edge Profiler software will maintain the  display with the peak centered on the window     D d Mmi  bil    Each time the Up   Down arrow key button is clicked  the profile displayed area is increased    decreased by a factor of two     F This button is not available when Knife Edge Profiler is used in Low Resolution  mode     Knife Edge Profiler Manual 49    Profile Setup  The Profile Setup button is selected from the Profile window     Setup Profile    x       Autoscale  The Auto Scale  selection forces the profile to be  displayed utilizing the full height of  the profile window       Grid  The Grid selection displays   a grid pattern behind the profile  The  M Grid grid is 
64. he Null button is accessed directly from the Power window     This button provides for ambient light suppression to permit accurate analysis of the light source   When Null is not active  the value displayed in the Power window is the total power incident on  the detector surface  When Null is active  the value displayed Power value is a result of the  desired input only     a To Activate or Deactivate Null  place mouse cursor over the Null button and click the  LEFT mouse button     Suppressing Ambient Light   CS le  appears  instructing the user to remove   the light source and press OK     The system now measures the ambient  light level  The OK button will cause the      Cancel   software to subtract the measured level  from the subsequent measurements     AN To measure MULL First switch off the laser and press OF             x  The final prompt will indicate when the measurement has taken    place and the laser can be turned on again  The OK button will  AN Switch on the laser activate the Null  A  Null  banner appears in the power display  with the calculated value of ambient light displayed underneath        Null  4 055       Power Setup    Power Setup is selected from the Setup button in the Power window     Power Setup allows the user to configure the power measurement capability of the Power  window     Knife Edge Profiler Manual 44    Power Setup           Urita Display   fe oma CO pw C dBm    Neede    Digt    Bar  Filter Statue Power   Load   MG4FLT   OnDff    OF 
65. he mouse left hand button  twice changes the window to a graphical presentation only without the measurement data  displayed on the right hand side of the window     Placing the mouse cursor over the Projection display and pressing the mouse left hand button  twice changes the modified position window back to its original size and shape       gt  The Projection window uses a time intensive calculation  When Projection is ON  the update rate may slow down     F This window is not available in High Resolution mode     The Projection function provides either a two dimensional or a three dimensional view of the  beam intensity profile     The Projection Window has a Projection Setup dialog for setting the parameters associated with  this presentation     The Projection is created using a mathematical process called  Reconstructive Tomography    The displayed resolution is 32x32 regardless of beam size  This same type of process is used by  X ray systems to create X ray images  More knife edges will yield a greater the level of detail  For  a beam distribution that is significantly non gaussian the standard seven knife edge system can  reconstruct a plot that closely matches the real beam  When examining near gaussian beams  three knife edges can give an accurate intensity distribution      F To get help on this window press F1 when it is active  The Active window is  indicated with the highlighted title bar     Knife Edge Profiler Manual 54    Projection Setup  The Projection Set
66. he user will  be notified when these limits are exceeded     Min   Min is selected in the Power Setup dialog  The min setting is displayed in the    Range and Limits  tab    The minimum setting corresponds to a user selected minimum power level  The Min setting in    the Range dialog section will set the minimum value displayed on the power scale  The Min  setting in the Alarm Limits dialog section will be displayed appropriately on the Power Window       gt  When the Alarm is active and the appropriate Min Max levels are set  the user will  be notified when these limits are exceeded     Knife Edge Profiler Manual 47    Power Setup       Colors      Background Color  DataScale Color    Preview            OF    Cancel   System      Help        Colors  The Colors tab allows the user to specify colors for the Power Window  A  standard Windows color pallet is available        Upon selecting the required parameter value  press OK to confirm the selection  press Cancel to  restore the previous settings  Alternatively  press System button to reach the System Setup        Al v Profile    The V Profile window can be turned ON and OFF from the View menu  The keyboard shortcut is    F3  or click the Tool Bar button     Al    Fil Profile    le Ea  Relative Intensity     The Profile Window  graphically displays  details of the beam   s  intensity profile along the  V axis  In addition to the  profile information  there  is a display of beam  width at three different  clip levels  The thre
67. he user with the ability to view any stored file including  Data Log  Power  Plot  Width Position strip chart  Test  Profile Snapshots  and  ini files     To view a file     1   2     3     Select View File from the File menu        Contig files   iri   Plot files     plt   Chart files     crt   Bitmap files     bmp     JPEG files Interchange Format     ja   Text files    tet   Snapshot files     snp     x    The dialog will default to the Knife Edge Profiler directory where the files are typically  located     4  Click on a file from the list on the left     Knife Edge Profiler Manual 30    5  Click OK  The file can now be displayed in the notepad application     Create Filter File  Create Filter File is selected from the File menu  The keyboard shortcut is Ctrl A     This option enables the user to define a new optic filter file  Because silicon detectors saturate  easily  it is frequently necessary to insert one or more filters in front of the detector to attenuate  the beam and prevent saturation  The wavelength response of these filters is not flat  so it is  necessary to install the transmission properties of the filter in the software to obtain proper power  measurement and gain setting for the detector amplifier     The Filter file contains     The Filter file contains a table with two columns  The first column is the wavelength  in 1 nm steps  or larger steps   The second column is the known transmission of the filter for the corresponding  wavelength  The Knife Edge
68. ife Edge Profiler is automatically detected by Windows 98  Me  2000 and XP     With Windows NT 4 0 Plug and Play boards need to be installed manually  since NT 4 0  does not support Plug and Play     1  Insert the Knife Edge Profiler card into the PCI slot of the computer  Restart the  computer     2  Run software installation  SETUP EXE from the CD ROM     Software Installation    To install the software put the CD disk into the CD ROM drive and run SETUP EXE   In Windows 98  Me  NT4 0  2000  XP     1  Insert CD Disk in the CD drive   2  From the Windows desktop select Start  and choose Run   3  Type D  SETUP and then press Enter  where  D  is the CD ROM drive      During installation the system prompts the user to provide the SN  Please check the  detector head and CD Calibration Files folder for the valid SN     Knife Edge Profiler Manual 20    Uninstall is performed via Add Remove Program under Windows Control Panel     Connecting the Detector    The detector head has a cable with a 15 pin connector  The detector cable is connected  to the corresponding 15 pin connector on the interface board     Detector Head Connector Auxillary Connector       Interface Board Card Edge    Ez WARNING  do not plug the detector head into the interface card while the  computer is on  It may damage the electronics      F The KEP 3 KEP 7 switch is used to select the type of head that is connected  This  switch is set at the factory to match the head that is purchased  It can be moved only    
69. ions  utilizing Keyboard shortcuts     Help  Press F1 to obtain Help on the active window     Selection of menus     Press ALT and then the arrow keys then Enter  to select a menu item     OR       Hold down the ALT key and press the underlined letter  hot key  in the desired menu  item     OR       Press a shortcut key combination  Shortcuts are available for some menu items and are  displayed next to the menu item     Close Menu    Press the ESC key     Dialog Boxes      Text Entry   Select the text box you wish to change  Use the keyboard to enter the  desired text  When the correct text has been entered  press the  TAB  key to finish data  entry and move to the next control in the dialog box  If an error is made while typing text   pressing the  BACKSPACE  key will remove the character to the left of the text cursor and  move the cursor to the erased location  See also    Value Entry Box    for changing spin  buttons        Esc  This key is used to select the  Cancel  button in a dialog box  This function resets  settings to their previous values before the dialog box was opened        ENTER  This key is used to select the  OK  button in a dialog box      TAB  This key moves the input focus to the next control in a dialog box     The table below summarizes all the software shortcuts and control keys      Command   Description J Shortcut   Icon  configuration file    _  configuration file         Create Filter File Starts the Create Filter file process   Print Text File Di
70. ions in  the current session     To activate Reset place the mouse cursor at this button and click its LEFT button once  The Plot    Chart graph will redraw after the Reset  The currently accumulated data points are discarded     Save Chart  The Save Chart button is selected from the Chart window     Knife Edge Profiler Manual 61    This option enables the user to save up to 500 data points from the current session  The user can  save several Chart files during the same session     Data is saved in a file named   CHT file as a text file  where     is composed of the date and time  as follows   ddhhmmss   CHT    Where dd   day  hh   hour  mm   minutes  ss   seconds     The default file name can be changed later  This process will allow for uninterrupted data  collection     Chart file Format    The data is stored in TEXT file format and contains the following information     General details  system name  date  etc     Time values paired with the displayed X  amp  Y Position values  Or     A table of time values paired with the displayed V  amp  W Width values     All dimension values are in microns     An example Chart file   Chart File Data  Knife Edge Profiler  Version 1 00    Erler Cr Program Fiuhes KEP LOSS LOLIGO S4JO CHE  Date  10 Mar 2005  Tame  LOr 05240    S N  1035  Average  a  Wavelength  1300  nm   Clip Level  13293   Time Width W Width V   sec   um   um   O40 1682 566 Tile gee  Oe   eee 1661 088 2248 v82   etc     Chart Setup    Chart Setup is selected from the Se
71. ip level defines the percentage of the peak intensity profile at which beam is  measured  For example  a clip level of 50  indicates that the beam is to be measured  at its full width at half maximum  FWHM   A clip level of 13 5  measures the beam at a  point that is 13 5  of the peak of the profile  The 13 5  level corresponds to the 1 e2  point of a Gaussian profile     The Knife Edge Profiler obtains the beam profile information as outlined in the Theory of  operation     The profile peak is found and set to 100   The Profile is searched to find the points most closely  matching the clip level  The distance between the specified clip level points is the beam width     If no point matches the clip level exactly linear interpolation is used to find the edge precisely     If the profile crosses the clip level more than 2 times  the system picks the edges closest to the  beam profile center of gravity   typically the main lobe      If the edge of the beam is cut off because it intersects the edge of the aperture  the profile will  appear truncated on that edge     Beam Centroid Location    Before each blade there is a  start of scan  signal acting as an indicator for the beam location on  the detector surface  Each system is calibrated relative to the start of scan  The system  calculates the time from start of scan to the  center of gravity  of the profile  The  center of  gravity  is determined for the W axis with the following calculation     W   SUM  w   p w   A    Knife E
72. ip levels 1 2  and 3  d  Values are in microns  6  GetGaussCorrelation  a  Returns horizontal and vertical correlation in a 2 elements array  b  Values are in percent  7  GetAmplitudeVectorX  a  Returns horizontal profile as array with values from 0 0 to 100 0  b  Array length is a function of capture size  8  GetAmplitudeVectorY  a  Returns vertical profile as array with values from 0 0 to 100 0  b  Array length is a function of capture size  9  GetMatrix  a  Returns input matrix array from KEP detector with values from 0 to 255  b  Array length is a function of capture size  10  GetPower  a  Returns power measured in milliwatts    Knife Edge Profiler Manual 102    Newport Corporation  Worldwide Headquarters    1791 Deere Avenue  Irvine  CA 92606     In U S    800 222 6440  Tel  949 863 3144  Fax  949 253 1680    Internet  www newport com  E mail  sales  newport com    Visit Newport Online at  www newport com           ree Newport Corporation  Irvine  California  has  ii been certified compliant vat ISO 9001 by the    ISO 9001 British Standards Institution   FM 27a     Knife Edge Profiler Manual       Printed in the USA    103    
73. isplays  Average can be set to integer values between 1 and 20  A value of 1  corresponds to no averaging  When a value of 10 is chosen  ten successive measurements are  averaged and the result is displayed  When an eleventh measurement is taken  the first  measurement value is dropped and the second through the eleventh are averaged  etc     The selected value determines the number of successive measurements that will be averaged  A  successive averaging technique results in an update rate that is not affected     Knife Edge Profiler Manual 75    Average       Select an Average value from the Value Entry Box  The  selected value is displayed on the Status Bar     Head Tilt   Head Tilt is accessed through the System Settings in System Menu    The Head Tilt option is utilized to input the actual orientation of the head  This option will orient  the on screen view to match physical reality  This option is utilized in a situation where the  measured width of a laser beam does not coincide exactly with either the V or W axes defined by  the Knife Edge Profiler     The Head Tilt feature is especially important when analyzing elliptical beams  When the knife   edges are not properly oriented with respect to the major and minor axes of the ellipse  the width  measurements along V and W will not reflect the true maximum and minimum widths of the  beam  If the beam cannot be rotated  it is necessary to physically rotate the measuring head  about the optic axis of the laser beam     F 
74. key to access Help information on the current active window     To access the on line Knife Edge Profiler Manual  select Contents form the Help menu  The  Contents topics are organized into chapters  To find information on a desired topic  click on the  displayed chapter heading     You can return to the Table of Contents by clicking Contents   To find specific information fast use the Search for Help On menu item under the Help menu     Search for Help On  Additional help can be displayed on the current subject by pressing F1     To find help information quickly  select Search for Help On from the Help menu  This option will  bring up a list of all the topics  Type the first few letters of the topic  The search engine will  automatically select any topic that matches the entry  If no entries match your topic scroll through  the list to find a related topic you may also click the Find tab  Windows will compile a cross   reference list of all the word used in the Help file  Using Find will often pinpoint the exact topics of  interest     Active Window Te    The Active Window can be identified by a colored title bar background  A depressed tool bar  button indicates the windows available for selection  Activate a window by clicking on any part of  the window  To get context sensitive help on the active window select F1 or select Active  Window from the Help menu  This will bring up the help topic for the current active Window     Newport on the Web     The Website item in the H
75. lection  Click Cancel to  Preview   restore the previous settings  Alternatively   press the System button to reach the System  Setup            OF  Cancel   System      Help      Knife Edge Profiler Manual 57    ES  Plot Power    The Power Plot Window can be selected from the View menu  The keyboard shortcut is F7  or    click the Tool Bar button kd  Fx Plot Power Mel x     Power  rmi  Num  of points  50    1 255  1 105 AN UNHA HHH  0 955  0 805    0 655       0 505  Elapsed time  54sec  Time  1 0 Gecdivy       Power Plot window provides a graphical display of beam Power versus Time  The graph  presentation includes the temporal power fluctuations and provides a way to observe long term  power fluctuations  The Power Plot window also displays the number of points accumulated   elapsed time clock and the exact Time Division partition     Plot Buttons       Pause  The Pause button is used to temporarily stop power logging  Press the button  again to continue       Reset  The Reset button is used to reset all accumulated data   History displayed in the  current session       Save  The Save button is used to save current or most recent 500 measurements  displayed       Setup  The Setup button is used to set the relevant Plot Setup parameters      F To get help on this window press F1 when it is active  The Active window is the  window with the highlighted title bar     Reset  The Rest button is accessed from the Plot or Chart windows     The Reset option enables the user to rese
76. lide switch on the plug in card        Add Calibration Files    Add Detector Head Fa    New Connections Add Calibration Files            Input Detector Seral Humber to Det S  N  Insert Original  Calibration Files Diskette to flappy dive  or Update CD disk and  press Copy    button     Det  S M   715    Copying file 715 NG4    LITT LITT LL Abort    Jag  OK    Cancel   Help               abandon     Copy all calibration  files from the CD disk   or floppy disk   provided with the  sensor head to the  current Knife Edge  Profiler working  directory    Upon activating this  option  a data entry  box is displayed  Input  the detector Serial  Number  then  appropriate drive  where the disk was  inserted  Press Copy  to confirm the  selection  Cancel to    During the copying operation  a message box is displayed  presenting the name of the  file being copied to Knife Edge Profiler working directory and the amount of data copied   in percentages   The Copy operation can be aborted any time by pressing the Abort    button     Knife Edge Profiler Manual    78    Windows Menu  The following commands and menu items are available from the this Menu     Cascade    Tile Vertical  Tile Horizontal  Arrange Icons    Cascade  This command will attempt arrange all open windows on top of each other  but slightly  Null for ease of selection     Tile Vertical  This command will attempt to tile the open windows horizontally along the top of the  window area  It works well with two open windows  When
77. located in the    Data    folder in the Knife Edge  Profiler directory  The Knife Edge Profiler directory is located in    Program Files    by  default     4 Click on the desired  ini file from the file list on the left     5  Click OK to load the file  The Knife Edge Profiler software will update all windows with  the new configuration     Automatic Configuration    The Knife Edge Profiler software will automatically save the current configuration each time it  is closed  The Save Settings on Exit condition is active by default  The user can deactivate  this condition from the Options menu  When this option is enabled  the Knife Edge Profiler  software will store the current configuration into the default configuration file   6   ini  upon  exit  When the software is started  it will automatically load the     ini file  A file named  Default ini is the default configuration of the Knife Edge Profiler software  it enables the user  to restore factory defaults     Knife Edge Profiler Manual 65    E Save Configuration File    Save Configuration File can be selected from the File menu  The keyboard shortcut is    Ctrl S  or click tool bar button El     This option allows the user to save the current Knife Edge Profiler software settings  These  configuration files have the extension   ini      To save the current configuration     1  Select Save Configuration File from the File menu     2  There is no need to change the  File Type  because  ini is the default     3  The Knife Ed
78. n  be arranged in any configuration  The Windows can show beam profiles  position diagrams  2D  and 3D contours  charts and a power meter  Interactive mouse control of each window allows a  variety of customized configurations  These customized configurations can be saved for later use     Arranging Windows  Several special commands for arranging windows can be found under the Windows menu     Knife Edge Profiler Manual 26    Status Bar    The status bar provides information on various Knife Edge Profiler settings and operational  conditions     If the Knife Edge Profiler system is not operating as intended  the Status bar provides a quick  summary of why it is not functioning properly  For example  the laser being used may have a  different wavelength  The status bar is a valuable aid in diagnosing unexpected results and can  quickly help you get back to desired operation          Wavelength  633nm   Clip Level 13 5    Average  OFF   HeadTilt  0     Aun   Low Resolution   Filter  HG4 4 465 mvt E    Status Bar        F The Status Bar also provides quick access to System setup parameters  Double    click the current Wavelength value to access the System setup  Toggle between  Run Step modes by double clicking the current mode on the Status Bar     Status Bar Panels   Wavelength     This panel will display the current wavelength  See    Wavelength      System Clip level     The clip level displayed on the status bar corresponds to the System Clip    Level  The System Clip Level
79. n 10uW of energy is detected  Verify that the laser light is reaching the sensor  If it appears  that the message is incorrect  treat it as a  Hardware Failure  message      Hardware Failure     A Hardware Failure message indicates that a problem exists with the Interface Board  One of the  following solutions could resolve this problem     1  The interface board settings do not match the software setup parameters  See Installing  the PCI Interface Board     2  The detector head is not connected or the cable is loose  See Connecting the detector     3  The KEP 7   KEP 3 switch on the Interface Board is not in the correct position  See  Connecting the detector     4  There is no measurement taken during 2   4 drum rotations  This might be due to some  problem in head or plug in card electronics      Power adjusting   This message is normal and can occur when     1  There is a sudden change in laser power     2  The user has just completed setting the Hardware or System Setup parameters        Laser Power Exceed Limit       This message indicates that the detector is collecting an excessive amount of light  Check the  input power level with a power meter to ensure the device is being used within the recommended  operating limits  With small beams this error can occur before the published power limit  See  Hardware for the published limits  If it appears that the message is in error treat it as a  Hardware  Failure  message     Knife Edge Profiler Manual 95    Operating Errors  
80. n displayed in the profile window   Use the Check Box to toggle the grid ON     Clip Levels  The Clip Levels are adjusted from the Profile Setup dialog     The three Clip Levels are utilized to display beam diameter information on the Profile and  Projection windows     F A clip level defines the percentage of the peak intensity profile at which beam is  measured  For example  a clip level of 50  indicates that the beam is to be measured    Knife Edge Profiler Manual 50    at its full width at half maximum  FWHM   whereas a clip level of 13 5  measures the  beam at a point which is 13 5  of the peak of the profile  The 13 5  level corresponds  to the 1 e2 point of a Gaussian profile     Both the V and W profile windows display the width of the beam at three clip levels  simultaneously  If Autoscale is ON  there will be three clip levels represented by solid horizontal  lines superimposed on the profile  The default clip levels are 80   50  and 13 5   The top two  clip levels are the Supplementary Clip Levels  The System clip level is on the bottom     To Change Clip Levels from Profile Setup Window     Change the Clip Level value for each one of them with the Value  Entry Box  The clip levels may be set in 0 1  increments     ClipLevels  2        Ea  II OU  0  j    l  I 500 H         13 5        To Change Clip Levels on the Profile Window     Place the mouse cursor just above or below the width level bar to be changed  then press the  mouse LEFT button and drag it up or down 
81. n on  use the following selection method     Beep    On Off    A check box is utilized in cases when there is a need to toggle a parameter ON or OFF  When the  parameter is active  a check mark  Y   is displayed inside the box     oy Place the mouse cursor at the option box and click the mouse LEFT button  Click the  mouse LEFT button again to deactivate the selection  The check mark is than removed  from inside the box     Highlight the required parameter box by pressing the TAB key  Press the SPACEBAR  key to toggle the check box parameter     Radio Button  To select a value from a short list of options  use this typical radio button entry     Dimension  fe 20 cf  SD    70  Move the mouse cursor and place it at the required option  Click the mouse LEFT button  once to select the option     Move the cursor to the required option  either by moving the mouse or by pressing the  TAB key  until the cursor is within the option list zone  Press the arrow keys to select the  option from the list     Using the Value Entry Box  To set a digital value parameter  use the Value Entry Box     po  oO       A Place the mouse cursor at either the Up or Down arrow buttons displayed to the right of  this box  and click its LEFT button to change values for the selected parameter     Move the cursor to the required data box either by moving the mouse or by pressing  the TAB key  Type the desired value  The Enter key may change the value to meet the  system requirements     Knife Edge Profiler M
82. ne the amount of time utilized for a  complete chart display       Colors  The Colors tab allows the selection of  various plot colors  Each color selection uses the  typical Windows color pallet for selection     Utilize the Preview button to view the desired  selection before exiting the Chart Setup screen  If the  selected color is not desired  click the Cancel button  or select a new color     When you are satisfied with all of the selections  utilizing each tab  press OK to confirm the settings   Click Cancel to exit the Chart Setup screen and revert  to the previous settings     The Status Bar can be hidden or displayed by selecting Status Bar from the View menu or using    the keyboard shortcut Ctrl Insert     This option enables the user to toggle between Show Status Bar and Hide Status Bar     When Status Bar is active there is an additional line appearing at the bottom of the window  This  line contains panels displaying general system information and user settings     Knife Edge Profiler Manual    63    Tool Bar Command    The Tool Bar can be hidden or shown by selecting Tool Bar from the View menu or using the  keyboard shortcut Shift Insert     This option enables the user to toggle between the Show Tool Bar and Hide Tool Bar     When the Tool Bar is selected there is an additional line on top of the window containing Tools   picture shortcuts to some of the most common used system functions  along with date time  information     When this option is not selected 
83. nmi     M On Otr       W Sound              Min  0 000   Min 11 000      Ej a  Mas  10 000   Max   5 000          OF    Cancel   System      Help        Power Range  The Power Range selection allows the user to specify the display range   Select the values appropriate to the current laser input power       Alarm limits  The On Off box must be checked to access the Alarm Limit values  Set  the desired values for visual alarm indicators in the Power Window  A Computer beep  will also be active if the Sound box is checked  The numerical power value is turned in to  red indicating the power value is exceeded        Power Range  The Power Range is selected from the Power Setup window     The Power Range magnifies the beam power display  The needle graph display is affected  accordingly     This is a useful feature when monitoring small changes in beam power     Define the Zoom area by setting the minimum and maximum power levels from Min or Max box  utilizing the Value Entry Box     Alarm Limits  The Alarm Limits are selected from the Power Setup dialog     The limits are defined by the area within the needle graph display   Audible and visual indicators will warn the user if the power drifts  outside the user specified zone  The allowed zones are marked in  black color  while non permitted operation zones are marked in  red on the needle graph  When the On Off box is checked  visual  indicators will be provided when the user specified limits have  been exceeded  The Beep box will
84. ntribute to the overall noise level in the system  A  brief discussion of the most common noise sources follows     Electronic noise can be a concern with instruments being used in association with lasers  The  Knife Edge Profiler has passed CE Mark tests indicating that it is resistant to most EMI radiation   Still  Intense High frequency sources can induce noise into the cables and detector head  electronics  Avoid grounding the detector head and Knife Edge Profiler chassis with the laser or  its power supply in a manner that could make them susceptible to ground loops  Severe damage  to the detector head and electronics may result  It is also recommended that the Knife Edge  Profiler system power supply be surge protected and isolated from the laser power source     Background Light noise seen by the detector head is another problem that should be closely   monitored  This noise comes from sunlight  room lights  flashlamps  and instrumentation lights   One of the Filter filters can be used to reduce background light  The Power Null feature can be  used to remove the ambient light from the power reading     Thermal noise can also affect the long term stability of the Knife Edge Profiler  Drift in detector  head voltage and A D converter circuits due to large changes in room and instrumentation  temperatures can contribute to background noise  The system should be allowed to reach a  stable operating temperature each time it is used  This can take as much as 15 to 20 minutes
85. o enable Visual Basic events  This is compatible with Visual Basic  applications that used simple broadcast events   b  Default is set to FALSE  no Visual Basic events   3  SettingsUpdated  a  Used on startup to inform the calling application that the Knife Edge Profiler   KEP  has finished its initialization  b  Used with the ccdUpdated type described above  4  DataUpdated  a  Used by non Visual Basic applications   b  Set to 0 by calling application to request new measurement from the KEP  c  Setto1 by KEP to inform calling application that a new measurement has been  made and processed    Knife Edge Profiler Manual 101    Methods    1  HideForm  a  When launched  the KEP window is displayed  This property allows the window  to be hidden without affecting measurements  thereby freeing the screen for the  calling application   2  ShowForm  a  Allows KEP window to be displayed  3  GetCentroid  a  Returns horizontal and vertical centroid in a 2 elements array  b  Values are in microns  4  GetBeamWidths  a  Returns array of horizontal and vertical beamwidths at all 3 clip levels  b  First 3 elements are horizontal beamwidths at clip levels 1 2  and 3  c  Second 3 elements are vertical beamwidths at clip levels 1 2  and 3  d  Values are in microns  5  GetGaussWidths  a  Returns array of horizontal and vertical gaussian widths at all 3 clip levels  b  First 3 elements are horizontal gaussian widths at clip levels 1 2  and 3  c  Second 3 elements are vertical gaussian widths at cl
86. ofile Ww  F   4  Position FS    Projection F      Plot Fe  Chart F      ToolBar Shift Ins  w Status Bar Ctrl Ins       The corresponding keyboard shortcuts are shown to the left of the corresponding item  These  shortcuts may be activated from the Main Window by pressing the appropriate keyboard  combination     A check mark in front of a menu item indicates that that function is active     If a menu item is gray it indicates that item is unavailable  Conditions or Setup parameters may  be required for the item to be active  Review the user manual text or help associated with the  gray item for additional setup information     F When in Low Resolution  all display windows are available and can be activated  at the same time     F When in High Resolution  the Position Window is not available and only one  Profile window can be open at once  This limitation is a result of a hardware limitation     Power    The Power Window can be turned ON and OFF by choosing Power from the View menu  The    keyboard shortcut is F2  or click the Power icon in the Tool Bar     E Power clafi  The Power selection activates the power  meter display window  The display shows  NG4 FLT real time power as a needle graph or a  digital value  Several buttons provide  easy and quick control of the Power  functionality        Placing the mouse cursor over the Power  display and pressing the mouse left hand  button twice changes the position  window to a graphical presentation only  without the measurement 
87. ofiler head and provide  precise rotation of the head about  the optical axis     It is sometimes necessary to rotate  the Knife Edge Profiler head about  the optical axis  Each head is  provided with three M4 threaded  mounting holes on its rear plate for  this purpose        Knife Edge Profiler Manual 97    KEP FC  Fiber Adapter     The fiber adapter is provided with an FC connector and is designed to just fit onto the aperture of  the Knife Edge Profiler detector head  The fiber adapter can firmly hold an optical fiber with FC  connector end quite close to the detector knife edge plane for measurement of its output beam    profile   Dimensions are in mm        Knife Edge Profiler Manual    98    Knife Edge Profiler head types and their critical internal  dimensions          Knife edge  Aperture Detector Sensitlve surface  SS eee  Front of KEP  er       Knife Edge Profiler Manual 99     amp  ActiveX Control    Introduction    As mentioned in previous chapters  Knife Edge Profiler is a full capture and analysis application  with sophisticated capabilities  However  many customers have special analysis demands and  tools  yet are lacking data collection capabilities  In order to meet this demand  the Knife Edge  Profiler can act as an ActiveX server  This allows system integrators to integrate the Knife Edge  Profilers data capture capabilities with legacy analysis packages     This has been tested in LabVIEW 7 0  National Instruments  as well as Visual Basic 6 0   Microsoft 
88. om the Test Window  This Setup window is used to enter general  information about the Test and to activate any one of the nine parameters  When first configured   the Min and Max values will be based on the current detector head limits       User Name  User Data  The User  Name   User Data lines are available    to enter information associated with  User Marne    the test   User Data      Measurements  Any one of the    Taa hin ee listed 9 parameters can be activated  by placing the mouse cursor at the    v Power  mw   0 0    foo   option box and clicking its LEFT      width     um  joo      fomi   button once  Each active parameter    Gaussian Width     uml joo   foon requires a minimum and maximum  w Gaussian Fit      ho   level setting    F Width Ww fum       I fino      7 Gaussian width W  um    f oo00 0   Click OK to confirm the setting or click  v Gaussian Fit W    1 00   Cancel to abort     w Position    um   5000     5000 0    v Fosition  fum          5000 0      OK   Cancel   System      Help          3  Step    Access the Step command to nee Step from the Options menu  The keyboard shortcut    is F9 or you can click the icon on the Tool Bar     tf  ae       1 The Step tool bar button will be disabled unless the system is in Step mode  To enter Step  mode  select System Setup from the Setup menu and toggle from Run Mode      a    To take the next measurement either  click on the Step sign  3  in tool bar  press F9 or select  Step from the Options menu     Server Mode
89. or to activating  Print Window     E The time required for printing graphics screens in Windows environment is dependent on  the computer resources    Print Screen    Print Screen enables an immediate printing of the current full screen display   Print Screen can be selected from the File menu  or the keyboard shortcut Ctrl F12     A message box  Printing     is displayed as long as the screen graphics are being transferred  from the program to the printer via the Windows Print Manager     To select and setup a specific printer  select Print Setup from the File menu prior to selecting  Print Window     F The time required for printing graphics screens in Windows environment is dependent on  the computer resources     Print Setup  Print Setup is selected from the File menu     This option enables the user to load the appropriate printer driver  set the orientation and paper  size  Make sure the appropriate printer driver is selected prior to activating Print File     Knife Edge Profiler Manual 33    E  Start Log    Start Log is selected from the Options menu  or the Tool Bar     Mstan Log is disabled until the following parameters are configured in Log Setup     The duration of the experiment     The rate of data logging    The Log file name   When the data saving process is active a Log banner is displayed in the top corner of the  Window area   During data collection the Start Log menu item and tool bar icon will change to Stop Log     g Stop Log    Stop Log is selected from
90. orization Number  RMA    Return the product to Newport Corporation  freight prepaid   clearly marked with the RMA  and we will repair or replace it at our discretion  Newport is  not responsible for damage occurring in transit and is not obligated to accept products  returned without an RMA      E mail  rma service newport com    When calling Newport Corporation  please provide the customer care representative with the  following information       Your Contact Information    Serial number or original order number    Description of problem  i e   hardware or software     To help our Technical Support Representative diagnose your problem  please note the  following conditions       Is the system used for manufacturing or research and development      What was the state of the system right before the problem      Have you seen this problem before  If so  how often      Can the system continue to operate with this problem  Or is the system non operational     Can you identify anything that was different before this problem occurred     Knife Edge Profiler Manual 5    Knife Edge Profiler Help Contents     amp  Introduction    Welcome to the Knife Edge Profiler   Theory of Operation   Overview   Knife Edge Profiler and Beam Diagnostics  Quick Start    Quick Start  Complete System  Quick Start  Components     amp  Setup    Hardware Installation  Care  amp  Handling  Detector Head  Interface Board  Filters  Laser Safety  Hardware Requirements  Installing the PCI Interface Board  Inst
91. r Head    The detector head is a precision instrument and should be handled with care  If the head is  dropped it may be damaged  Do not plug the detector head into the interface card while the  computer is on  Damage to the electronics may result  When not in use  keep the cap over  the aperture to prevent dust from accumulating on the sensor and the knife edges  The knife   edges are delicate and will be damaged if they hit any object  The filters   if provided  are the  only objects that may be safely inserted into the detector head  Please do not remove the  covers  since the internal systems are delicate and can easily be damaged     Interface Board    The interface board is a static sensitive electronic item  Keep it in an anti static bag when not  installed in a computer  Avoid temperature and moisture extremes  The board should only be  installed when computer power is OFF     Filters    Filters are provided with the silicon versions of the detector heads  These filters have been  precisely calibrated to a particular Knife Edge Profiler head  Therefore  they share the same  serial number  Dust  scratches and other types of contamination will degrade the accuracy of  the system  Please keep unused filters in the storage case  Please be gentle when handling  these fragile items  See    Selecting a Filter    for more information     Laser Safety  Please comply with all relevant Laser safety procedures and precautions when using this    Knife Edge Profiler Manual 16    de
92. r Stop Test if the Test Window is open  is found under the Options menu  This    option can also be selected with the Tool Bar button  This function is used to start and stop  automatic online Pass Fail testing for user selected parameters       Test of x   information       Uzer Hame    Uzer Data    Clip Level  13 5  Parameters that are not specified  Average  DFF in Test Setup are marked as   Test Parameters i Data Status Skipped in the Test window     Power  mW  oo   too   aaa  Posse   width Veum  oo   100000   4067 408   Passed      Gaussian ftw    oo   a0   osm   Passed  Width Warn  oo   0000 0  2466 92   Passed      Gaussian ftw     0 0   ao   osre   Passed    Position X um   Position Yum     Test buttons      Pause  The Pause button temporarily stops testing  Press the button again to continue     Print  The Print button prints the test results directly to the default Windows printer       Save  The Save button saves the current test results in a file named   tst  See Importing  Files into Excel for information on creating charts from test files       Setup  The Setup button will display the configuration window utilized to set the test  parameters     To close the Test window  select Stop Test under the Options menu  You can also click the Test    button on the Tool Bar      F To get help on this window press F1 when it is active  The Active window is  indicated with the highlighted title bar     Knife Edge Profiler Manual 69    Test Setup    Test Setup is selected fr
93. rench for Silicon Heads Only    A basic Knife Edge Profiler system includes the following items     A detector head        KEP 3 IR  a three knife edge head for the 800 1800 nm wavelength range   KEP 3 SL  a three knife edge head for the 350 1100 nm wavelength range   KEP 3 UV  a three knife edge head for the 190 1100 nm wavelength range   KEP 7 IR  a seven knife edge head for the 800 1800 nm wavelength range   KEP 7 SL  a seven knife edge head for the 350 1100 nm wavelength range   KEP 7 UV  a seven knife edge head for the 190 1100 nm wavelength range                  32 bit PCI Interface Board   The Interface Board is a 1 2 length PCI card used for connecting the various detector heads to  the computer    Windows Software   The Knife Edge Profiler software is contained on the installation CD  The CD also contains the  user manual in  pdf format  readme txt file and all of the required support files    Printed Manual   The printed manual contains the same information as the On line Help in the software  A  README TXT on the installation CD may have corrections to the manual and the on line help     Filter Kit   The KEP 7 and KEP 3 Silicon heads come with neutral density filters  The NG4  amp  NG9 filters are  provided to extend the power range of the head from 5 mW to 1W  The NG4 filter comes  preinstalled and provides 10  transmission at 633 nm  The NG9 is in a protective filter case and  provides 0 5  transmission at 633 nm  The filter kit also includes a hex wrench utiliz
94. responds to the  maximum 5 Hz update rate  The displayed data corresponds to a 5 Hz collection rate even  though the display may not update at that rate  The higher the value of this scale  the slower the  graph will scroll     Units Plot   The Units are selected from the Plot Setup dialog    The user can toggle between mW and uW units for the Plot presentation   Select the units with the Radio Buttons     Plot Setup    aise   Colors  The Colors tab allows the selection of various    plot colors  Each color selection uses the typical  Windows color pallet for selection     B iorn Color A complete windows color pallet is available for the  B Fi Color desired color selection     oT Press OK to confirm the selection or CANCEL to restore  previous settings  Alternatively  press System button to  reach the System Setup to change global system  parameters         Colors    OF    Cancel   System      Help      Knife Edge Profiler Manual 60    Chart Width Position    The Chart Window can be selected from the View menu  the keyboard shortcut F8  or the    following Tool Bar button     F This window is not available in High Resolution mode     ES Chart Width Position    2 Syx   The Width Position Chart window    Position  um  Num  of points  58 provides a real time strip chart  display of beam position  X Y   versus time  or beam width of V  and W profiles measured at the  System Clip Level     These charts enable the user to  observe beam position stability   or beam width variations 
95. ress    and  System interrupt IRQ   are stored separately in a Newport KEP Series cfg file     Save Image as     The Save Image as function is selected from the Options Menu   This function is used to save the screen presentation as a   bmp or   jpg file     Knife Edge Profiler Manual 66    To save a file     1  Select Save Image As    from the Options menu   2  Select the  File Type   omp or jpg    3  Select the desired file directory   4    Type a filename for the image file in the box below the word  File name   The file saving  process will automatically attach the appropriate file extension     5  Click OK     Save Snapshot    The Save Snapshot as function is selected from the Options Menu    The snapshot image is captured as soon as you select the Save Snapshot option  You then save  the snapshot image as an  SNP file  The snapshot file is saved in binary format and can only be  processed by this application     To save a file     1  Open the Options menu and select Save Snapshot  The Save Snapshot File window  displays     2  Enter a filename for the snapshot file   3  Click OK     View Snapshot  To view a snapshot file     1  Open the Options menu and select View Snapshot  The Load Snapshot File window  displays     2  Select a snapshot file     3  Click Open  The snapshot file displays     To close a Snapshot file  open the Options menu and unselect View Snapshot  The Knife Edge  Profiler restores real time measurement displays  or click 3 in the upper right corner o
96. sor output  The Filter option allows the  user to load or remove any pre defined filter transmission file to be utilized by the power  measurement function     Choose a Filter file     The silicon detector heads come with 2 pre defined Filter files   NG4 and NG9   See Selecting a  Filter  A custom filter file can be created through the Create Filter File command in the File  menu  This is helpful if you want to calibrate the Knife Edge Profiler system for accurate power  measurement relative to a known instrument at a specified wavelength     Select the Filter File    Filter  Load MGA FLT    To inform Knife Edge Profiler  which filter is installed in the  detector head  click on the Load button in the Power Setup dialog  A file list is displayed   presenting all the available filter files  Select the desired filter file and confirm with the OK button     Using the Filter    __ Filter physically install the selected filter into the Knife Edge Profiler head   see Care and    Handling  Click the filter button on the power meter panel display to activate the selected Filter  file  The power measuring function will calculate power utilizing the selected Filter file  A banner    Knife Edge Profiler Manual 43    containing the selected filter filename will appear in the power display   for example WuEEAH SLES      Fiter  Glick the Filter button on the power meter panel display again to deactivate the    selected Filter  Physically remove the Filter from the detector head     Null  T
97. splays and Open dialog to load and print Ctrl P  any saved Knife Edge Profiler file in text B  format       Print BMP File Displays and Open dialog to load and print Ctrl B  any saved Knife Edge Profiler file in  omp or  jog format    Knife Edge Profiler Manual 24       Senio perste oo  Print Screen  Prints the Entire Screen   Ctri F12  Exit  Exits the Knife Edge Profiler Software   _ Ctri X    Help Active Window Displays Help Information on Current Active a F   Window    ere Lear i    Displays Profile V Window    Displays Profile W Window    Displays Position Window in Low Resolution aa  Mode   Displays 2D or 3D Projection in Low  gt   Resolution Mode   Displays the Power Plot Window  Displays Chart Window in Low Resolution ia  Mode    Increments the Step Display if the System is  in Step Mode    Test Opens the Test Window  Server Mode Start TCP IP remote control    rint Window   oolBar   tatus Bar  Close All Windows    Dialog  Search Function    Tool Bar    The tool bar is a collection of shortcut buttons that are used frequently  Each shortcut is  represented with a special icon  picture  called a tool button        K To activate a tool button  place the mouse over the button and click the LEFT mouse    button  The button will change both color and shadow to designate that the function is  active     Knife Edge Profiler Manual 25    Buttons available on the Tool Bar        Inactive Tool buttons    If a tool is not available it will be displayed in a gray outline form  The 
98. ss is known as  Reconstructive Tomography   The same type of process is  used by X ray systems to create X ray images  A larger number of knife edges will create better  detail on non gaussian beams  For a beam distribution that is significantly non gaussian  the  standard seven knife edge system can reconstruct a plot that closely matches the real beam           knife Edges    There are two primary knife edges used for the main profile display  These knife edges generate  profiles referred to as W and V  These knife edges are set perpendicular to each other and are  oriented at 45 degrees in relation to the base of the head  These profiles are used to provide  beam width  position and gaussian fit analysis  The other knife edges are used for Reconstructive    Knife Edge Profiler Manual 12    Tomography     To increase the usable power range of the Silicon heads to the NG4   10  transmission  and  NG9   0 5  transmission  filters can be inserted between the knife edge and the sensor  This  location will prevent the attenuation from distorting the beam     The data is combined with user selected graphics and calculated analysis results for display in a  user controlled window  A wide variety of system functions also provide the ability to print  information  perform pass fail testing  control capture rates  and log data     Overview          5    _  Tig    s a s  i i z a    i  1 i 7  y   k  4 n    j   Me  i i           m  d i      r P    ee ee    ED HD Os Filters  amp  Allen W
99. t all accumulated data for the Plot   Chart functions in  the current session     To activate Reset place the mouse cursor at this button and click its LEFT button once  The Plot    Chart graph will redraw after the Reset  The currently accumulated data points are discarded     Save Plot  The Save button is accessed from the Plot window     This option enables the user to save up to 500 data points  Several Plot files can be saved during  the same session     Knife Edge Profiler Manual 58    Data is saved as text in a file named   plt  where     is composed of the date and time as follows   ddhhmmss  PLT    Where dd   day  hh   hour  mm   minutes  ss   seconds    The default file name can be changed later  This process will allow for uninterrupted data  collection    Plot file Format     The data is stored in TEXT file format and contains the following data     General details like system name  date  etc     A table of time values paired with the displayed Power values in milliwatts     Plot Setup  Plot Setup is selected from the Setup button in the Plot window     W AutoR ange On Off    Min   4 005 5   Range  The Range tab provides controls to allow    Max   4 505   the user to specify the vertical plot scale     OF    Cancel   System      Help         Plot Range    The Plot Range is selected from the Plot Setup window  The Plot Setup window is accessed  with the Setup button in the window then select the    Range    tab     The vertical scale of the Plot graph can either be
100. table     We allow blade eccentricity of    30 um for the KEP 7     Knife Edge Profiler Manual    87    KEP 7 UV Detector Head       Dimensbns inmin     KEP 7  13 13 1    p       4       Entrance  Apera lure    S 525    50 D 105       Tread  Jn 35 2    e  Front Y iew Side Yew Hear Y iew  Spectral Response 190 1100  Number of knife edges 7    Sensor Input Aperture  Dimensions  Weight    Minimum Detectable Power  Relative Power Measurement    Maximum Power  633nm    Detector Type   Damage Threshold  Optical Dynamic Range  Beam Size Range  at 1 e    Beam Width Resolution    Beam Position Resolution  Beam Position Accuracy    Distance to Image Plane    Maximum Update Rate  Cable  Filters    9 mm Square  35 2 mm  W  x 105 mm  H  x 87 mm  L     22 OZ    10 uW   0 1 uW resolution   No filter  Power up to 5 mW   gt 0 1 mm diam     NG4 filter  Power up to 50 mW  NG9 filter  Power up to 1 W  UV Enhanced Si 10 10mm    200 W mm  with total power less than 5 mW at sensor  10 uW cm  to 10 W mm    no filter   9 mm to 15 um    width  lt  100 um  0 1 um  width  gt   100 um  1 0 um    1 um   15 um    3 5   0 08 mm back from front surface of Head   0 7   0 18 mm back from internal front surface of  entrance hole     5 Hz  see Speed Issues   2 5 m long attached to the head    NG4  amp  NG9 filters can be used for the 400 1100nm  See  filter files NG4 FLT  amp  NGQ9 FLT for a Text format  transmission table     We allow blade eccentricity of    30 um for the KEP 7     Knife Edge Profiler Manual  
101. tem Menu   This function allows the user to configure an additional detector head     New Connections tab  The currently selected file is displayed at the following screen     Add Detector Head Ea         Fress Det  S N button im order to insert new detector S M   Select filename to be loaded for the new detector head in use via  Detector Calibration File dialog box     Detector Head    Load    OK    Cancel   Help      Pressing Load opens up a selection menu with all available calibration files for Knife Edge  Profiler  which are present at the system working directory       Load This option enables identifying the detector head serial number which is currently  being connected to the system  or selecting any required detector serial number from the  calibration file list  Press Ok button to confirm setting  or Cancel button to abort     Place the mouse at the required calibration file and press Open to confirm the selection     Knife Edge Profiler Manual 77    Detector Calibration File    Look ir  E Beam  nalyzer   e f    et E    I Bmp2000 aa  Ba999 up        Bal835 up   a  baz908 UP  j    Ba315 up      Ba  15 up          Open as read only      x        Files of tupe   Calibration files    up     Cancel    E            Note  When switching the type of measuring head from BM3 to BM7  or vice versa   please make sure you set the slide switch and set it at the right position  otherwise the    following error message is displayed     oe  Newport x     AN Change position of the s
102. tup button in the Chart window  The Chart Setup dialog  contains the following tabs     Knife Edge Profiler Manual 62    Chart Setup    W AutoR ange On Off    Min J  500    GE o E    es  r    Ei    OF    Cancel   System      Help      Chart Setup        Options  f Position     width  Time   sec div 0 2      OF    Cancel   System      Help      Chart Setup    Colors       Background Color  B Plot Color ey   Plot Color YA    Preview       OF    Cancel   System      Help      Status Bar Command             Range  Select a range for the Y axis on the Chart   The Auto Zoom box will control the Y axis mode     When the box is checked the chart Y axis is  automatically scaled by the software  When the Auto   Zoom box is not check  the user can set the Y scale  with the minimum and maximum value entry boxes in  the dialog  Data that occurs outside of the user  entered manual scale settings will be plotted as a  straight line at the top  or bottom of the scale  as  appropriate       Options  Selects either Position or Width versus  Time Charts  The position selection will graphically  display the absolute position data vs time in a strip  chart form  The Width selection will graphically  display the beam width vs time in a strip chart form   Please verify the range selection before exiting the  Chart Setup screen       Time scale  The Time selection will set the  horizontal scale on the Strip Chart  The horizontal  scale contains 20 divisions  Multiply the Time value  by 20 to determi
103. ty will be void if a surge protected outlet is not used with the  Knife Edge Profiler system  A surge protector will guard against high voltage  spikes  power fluctuations  and power surges     1  Check    Hardware Requirements      Follow    Installing the PCI Interface Board      Follow    Connecting the Detector        Perform    Software Installation      if not done already      oF a gt  e    Setup software settings     Configuring Software        Knife Edge Profiler Manual    15     amp  Setup    These topics cover the basic procedures for installation  setup and configuration of the Knife   Edge Profiler     Hardware Installation      gt  Before installing the Knife Edge Profiler hardware into the computer  make sure  that the PC computer system meets the Knife Edge Profiler Hardware Requirements     E Computer should be off before installing hardware into any computer     F The Knife Edge Profiler contains static sensitive electronic components  The Knife   Edge Profiler hardware should be handled with the same care as other computer  hardware  Care should be taken to avoid accidental electrostatic discharge when  connecting any cables to the Knife Edge Profiler hardware     LEF The Knife Edge Profiler warranty is void if a power protection outlet  surge  protector  is not used  A surge protector will protect the Knife Edge Profiler from high   voltage spikes  power fluctuations  and surges associated with laser laboratory  equipment     Care  amp  Handling    Detecto
104. up button is selected from the Projection window       Axes  The Axes selection         Taeidain zz activates axis orientation symbol     Grid  The Grid selection activates  meh Pee   Digital  The Digital selection  IV Axes WAW   2D CD displays the measurement results  Bie   Dimension  The Dimension Radio  Button selection toggles between    the 2D window Grid   I Grid as a digital display only   2D and 3D displays        OF    Cancel   System      Help      The Axes Direction indicators are selected from the Projection Setup  dialog  This dialog can be accessed with the Setup button in the  Projection window     When activated  this function displays the orientation of the V and W axes   Turn the Axes legend ON and OFF with the Check Box        Projection Grid    The Projection Grid is toggled from the Projection Setup dialog     This selection toggles the grid pattern in the position plot area  This setting is only available for  the 2D projection     Use the Check Box to turn the grid ON     Dimension  Dimension setting is selected from Projection Setup window     The Projection Window can display the beam intensity profile in two dimensions or three  This  function toggles between the 2D and 3D representations utilizing the radio buttons     F The fastest update rate is achieved with the 2D selection     Both the 2D and 3D views are mathematical constructions based on profile information obtained  from the knife edges     Knife Edge Profiler Manual 55    An example of Hig
105. uration settings   The Points mode sets data collection to the specified number of points     Knife Edge Profiler Manual 34      Interval  The time interval determines the time between consecutive data points     Duration  The total amount of time required to complete the data collection     Log Setup i            When the desired setup parameters  are selected  click the OK button   The data collection process  Log file   is initiated by selecting the Start Log  menu item     General   Settings          pm    C Points i 0 a      Manual  press SpaceBar to save Event   The end of each Log file contains a    Statistics summary  including   Minimum value  Maximum value   Mean value and Standard deviation  value for each parameter        Duration           hh  mm  s3    a  OO  00 0 A    hh  mm   33    o0  00 0   eni l  j The   log file can be imported into  other programs  See Importing Files  into Excel        F The Log setup is disabled  when data collection is in  progress     OK    Cancel   Help      Start Stop Link    The Start Stop Link is selected from the System Menu  The keyboard shortcut for Start Link is  Ctrl K     The Start Link command provides the capability to operate an RS 232 or TCP IP communication  channel for serial data transmission  Any displayed data or pre saved file can be transmitted from  Start Link  Typically this feature is used to transfer real time data from the Knife Edge Profiler  system to another computer over a null modem serial cable  The oth
106. used to provide a visual point  I Gaussian of reference on the displayed profile      Digital   Gaussian  The Gaussian  selection will provide a pure  Gaussian reference overlay on the  displayed profile  The Gaussian  selection also provides a numeral            View ClipLevels  2         W AutoScale       OF    Cancel   System      Help      Gaussian reference value     Digital  The Digital selection will display the current measurement results as digital    values only     Levels      The Level selection defines the clip levels for the three beam width  measuremenis   Auto Scale    Profile Auto Scale is accessed with the Profile Setup button in the display window   This option enables the user to toggle Auto Scale On and Off     To turn Auto Scale ON  use the Check Box  When Auto Scale is ON the beam intensity profile is  always normalized to fit 100  of display window      F Auto Scale must be ON for the clip level bars to be visible     When Auto Scale is OFF the beam intensity profile is not normalized to 100  of the display  window and the beam peak is observed as it changes  This function is helpful during a focusing  process  The peak intensity changes may be observed as a function of the focus  showing the  variations in beam   s peak with respect to the changes in beam size     F This function affects only the graphical presentation on window     Profile Grid   The Profile Grid is set from the Profile Setup dialog    The Profile Grid option turns on the grid patter
107. vice  The instrument will reflect a portion of the laser light  The resulting diffuse and  specular reflections may be dangerous     Hardware Requirements    To run the Knife Edge Profiler  the computer system must meet the following minimum  requirements  Where helpful we provide system recommendations     Min  Requirement Recommended  CPU  Pentium II Pentium III  System RAM  32 Megabytes 128 Megabytes  Floppy disk  3 5  1 44 Megabyte  CD Drive  x16 x50  Hard disk  20 Megabytes Free 200 Megabytes Free  Operating System  Windows 98 Me NT4 0   2000  XP  Mouse  Microsoft mouse or  compatible pointing  device  VGA  4 Megabytes Memory 8 Megabyte AGP Bus  16bit color Video card  Expansion Slot  One free 1   2 length 32 bit  PCI bus slot    Installing the PCI Interface Board    The interface board is used by Knife Edge Profiler to capture and digitize the beam  profiles from the detector head  The Knife Edge Profiler label identifies the interface  board        Knife Edge Profiler Interface Board     F The interface board is a static sensitive electronic device  It should be handled with  care to avoid exposure to static voltages  See    Care and Handling        Knife Edge Profiler Manual 17    Installation for Windows 98 Me 2000 XP    1  Insert the Knife Edge Profiler card into the PCI slot of the computer  Restart computer   The following message is displayed     Found New Hardware       m Other PC  Bridge Device    Installing           Found New Hardware Wizard    Welcome to the
108. w area  the  detecting area of the sensor is  represented by a 9x9 mm          4000  ym     UTET SLES square for the KEP 7 SL Head       by a5 mm diameter circle for  orientation      the KEP 3 SL version  and by a    3 mm diameter circle for the  KEP 3 IR version  Review the  current head specifications for  input aperture values not       previously given     The solid cross hair target appears within the main display area will represent the local Earth  reference frame  This reference display will remain fixed  The intersection of these two solid lines  is the center of the detector  The diagonal lines labeled V and W are the axes along which the  measurements are made and displayed     When a laser beam enters the aperture of the head  it is represented as a dotted ellipse  If the  beam is circularly symmetric  a dotted circle will appear  This ellipse indicates the  footprint  of  the beam in the plane of the rotating knife edges  The ellipse will change shape and orientation  as the beam expands and contracts in different directions  A small cross indicates the location of  the center of the beam  The X and Y coordinates of this cross are shown in um units under the  title  Centroid   A display box contains an estimated size of the major and minor axes of the  elliose  as well as the angle of orientation  under the title  Ellipse Data     Placing the mouse cursor over the Position display and pressing the mouse left hand button twice  changes the position window to a gr
109. when power is off     Selecting a Filter   When a Silicon head is ordered with a Knife Edge Profiler  it will come with two filters  This  section will help determine which filter to use  Here is the general guideline    No filter  Power up to 5 mW   NG4 filter  Power up to 50 mW   NG9 filter  Power up to 1 W   The actual filter transmission is dependent on Wavelength and can also vary from batch to  batch  The transmission values for a particular wavelength can be found in the filter files  included with the software   NG4 FLT and NG9 FLT      Focused Spot    When measuring a focused beam the system will usually need attenuation  A convenient  way to determine the correct attenuation is to first measure the power of the beam before  focusing  Focus and measure the power with the detector head using the NG4 10   If the  power reading is lower than 10  of the unfocused reading  use the NG9 0 5  filter  The  power densities associated with focused beams can easily saturate the silicon detector  A  saturated detector output will result in a low power reading     To install the filters    1  Remove the blank filter plate with the supplied Allen wrench   2  Carefully insert the desired filter   3  Secure the new filter with the Allen wrench     F Dust  scratches and other types of contamination will degrade the accuracy of the  filters  Please keep unused filters in the storage case     Knife Edge Profiler Manual 21    Custom Filters  amp  Power Calibration    A custom Filter file
110. window does not automatically zoom for small beams  To enable zoom mode   select the setup button and enable the zoom feature  The zoom function will scale the position  display relative to the current beam diameter     Display update rate is slow  The display update rate is dependent on several variables  See Speed Issues     Power is not correct    Check that the correct wavelength is entered into the System Setup dialog  Make sure the Filter  installed in the detector head matches the Filter selected in the software  Ensure that the sensor  is not saturated   See input specifications for Detector Heads   If using a small spot  check that  the power density levels  see Selecting a Filter   The relative power reading should be within    10  of the actual power level  If absolute power reading is required  setup a custom Filter file   A custom Filter file allows the user to enter a power a correction factor  This factor will be  multiplied by the transmission value at the specified wavelength     Calculation Issues  See the section on Accuracy     Knife Edge Profiler Manual 96     amp  Knife Edge Profiler Head Accessories  amp  Drawings    This section provides information about the Knife Edge Profiler head accessories  as well as data  about critical internal head dimensions  which are sometimes required for an optical design of the  beam path      KEP MNT  Knife Edge Profiler Rotation Mount     The Rotation Mount is designed to  attach to the M4 holes at the Knife   Edge Pr
111. y Known to the public or obtainable from public source   2  readily  apparent from the keyboard operation  visual display  or output reports of the Programs    3  previously in the possession of Customer or subsequently developed or acquired  without reliance on the Newport Programs  or  4  approved by Newport for release without  restriction     Service Information    This section contains information regarding factory service for the source  The user  should not attempt any maintenance or service of the system or optional equipment  beyond the procedures outlined in this manual  Any problem that cannot be resolved  should be referred to Newport Corporation     Knife Edge Profiler Manual 4    Technical Support Contacts    North America  amp  Asia Europe  Newport Corporation Service Dept  Micro Controle Spectra Physics S A   1791 Deere Ave  Zone Industrielle  Irvine  CA 92606 45340 Beaune la Rolande  France  Telephone   949  253 1694 Telephone   33  02 38 40 51 49    Telephone   800  222 6440 x31694    Asia     Newport Opto Electronics Technologies  253 Aidu Road  Bold  3  Flr 3  Sec C   Shanghai 200131  China  Telephone   86 21 5046 2300  Fax   86 21 5046 2323    Newport Corporation Calling Procedure    If there are any defects in material or workmanship or a failure to meet specifications   promptly notify Newport s Returns Department by calling 1 800 222 6440 or by visiting our  website at www newport com returns within the warranty period to obtain a Return Material  Auth
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
MOVIDAMR IP2023_I    ja-186j_manual  AC-DC Troubleshooting  Operating instructions Betriebsanleitung Mode d´emploi  Samsung SPE-100N  Users` Manual for the Revision Spreadsheets  Comline®  LH 5000 Operators manual version 4.14  131-K900型 取扱説明書 保証書付 ecoジョーズ ガスふろ給湯器 パック    Copyright © All rights reserved. 