Home

LEGENDAIR VENTILATOR

image

Contents

1. Sg FS D WEST CARE M E D C A L k T LEGENDAIR VENTILATOR Mixed ventilator integrating pressure and volume modes for the treatment of most acute and chronical respiratory pathologies Ventilation Comfort Quick and reactive Flow trigger that permits a fast adaptation of the patient with the device average reaction time of 75 ms once a trigger is detected as tested with the active test lung IngMar Medical model ASL 5000 Quiet device less than 30 dBA at 10 mbar Adaptability of ventilation small inertia of the turbine for optimal synchronization of the patient during ventilation E Possibility of setting a Target Vt and a Maximum pressure to attain it Precise flow and pressure sensors with adjustable and E triggers in pressure modes Oxygen enrichment and monitoring The Legendair is equipped with an oxygen connection at the back such as the enrichment of Oxygen is taken into consideration in the total flow delivered to the patient The FiO2 concentration can reach up to 50 of oxygen As an option the Legendair offers the possibility to connect an oxygen cell on the outlet of air to measure and monitor directly on the display of the unit the FiO2 concentration delivered and eventually set minimum and maximum alarms levels fiw The Legendair has been conceived to be user friendly Simplified maintenance Large LCD screen rr _LEGENDAIR Display of all the Quick and easy acce
2. ala ave ji O Trigg NGL 40 5 Levels o S cu Rate 15 c min 30 4 40 Apnea AUTO 20 3 305 IPAP EPAP Vti Vte I T FiO2 and patient triggering Alarms and monitoring menu The LEGENDAIR offers complete and comprehensive alarm screens Settings of minimum and maximum alarm values Display of the real measured ventilation values in the active cycles Display of the active alarm in a specific window Reading of the last 9 stored alarm messages with date and hour stamp All alarms are stored in the memory for an eventual retrieval with the Airox communication software package ALARMS AND MONITORING SCREEN a PSV ST Cnt paso Ovim 2 i javem 0 TORE O FI02 O 10 20 30 40 50 60 O Alarms Memory ALARMS AND MONITORING SCREEN E E Ere avem o ER O FIO2 Oo O Alarms Memory The LEGENDAIR can be used in Home care Adults and infants Long term acute care Intermediate care Weaning Pulmonology departments Transport
3. parallel with a specialized Designer the Legendair is conceived to answer the requirements and needs of the patients and users Large integrated handle Small Size A light weight of 4 5 kg including the internal battery Optimization of the Display features Easy and quick installation of the patient circuits As pressure and flow are closely linked we are looking at increasing the flow by progressively increasing the inspiration pressure without going above the maximum pressure limit settings To attain the target volume the inspiration pressure increases or decreases by increments between the respiratory cycles The modifications of the inspiration pressure are automatically done through a specific algorithm to obtain the target volume This method permits a quick reaction upon the detection of a disequilibrium with an optimum comfort for the patient due to the relatively small increments of increase and decrease in pressure Part No 1094095700 1094095900 SPECIFICATIONS Medical Device Class Weight Dimensions Power Supply Isolation Class Consumption External batteries Internal batteries 108 17 FAWCETT ROAD Description LEGENDAIR Equiped with power supply cable user s manual carrying bag LEGENDAIR Double Branch Equipped with exhalation block power supply cable user s manual carrying bag lI 4 5 kg H 154 x L 235 x W 315 mm 115 230 V 10 50 60 Hz lI 80 VA nominal and 90 V
4. 40 50 1400 ml AUTO 30 Tr gt 400 mi 20 8 to 55 mbar limited to 25 mbar P 3 to 15 of IPAP 00 Vti Vte Rate I T Ratio FiO2 IPAP EPAP and patient triggering SETTINGS IN PCV PACV MODE IPAP inspiratory pressure EPAP expiratory pressure Inspiratory ramp Rise time Minimum rate I T Ratio Inspiratory trigger Target VT Maximum pressure to reach Target Vt Monitoring SETTINGS IN CV ACV MODE Tidal Volume EPAP expiratory pressure Flow ramp Minimum rate I T ratio Inspiratory trigger Sigh Monitoring SETTINGS IN SIMV MODE Tidal Volume IPAP inspiratory pressure EPAP expiratory pressure SIMV Rate I T Ratio Inspiratory trigger Security rate Apnea Time Monitoring 8 to 55 mbar limited to 3 to 15 of IPAP Vti Vte Rate 1 T Ratio FiO2 IPAP EPAP and patient triggering Parameters 5 40 0 20 4 Levels z 5 60 a S 50 to 25 g 70 5 Levels gt g 50 50 1400 ml g 40 a 30 2 20 10 00 Parameters 50 1400 ml ACV o rA 10 Ci Vt 90 Rectangular or Decelerated O EPAP 80 5 60 a Saree 70 oO Rate 60 50 to 25 o WT 50 5 Levels 9 Tiga 40 g 30 Yes No Vt Sigh Vt from 1 0 to 2 0 of set Vt Sigh Rate 10 oO Rate 50 to 250 IPAP EPAP Vti Vte I T FiO2 and patient triggering Parameters 50 1400 ml SIMV 5 40 o Vt 500 ml 9 O IPAP 20 mbar 80 0 20 O EPAP 5 mbar 70 2 20 O SIMY Rate 6c min 60 50 to 25
5. A Maxi 24 V connection Lithium lon quick charge 6 to 11 hours autonomy Airox communication software The Airox communication software package is a complete and comprehensive PC software for the Legendair Twinair and all Smartair ventilators S ST and Plus The main functions of this software are Meeg rept from UW IODE 490 to Chet Tower EE 4 MAN iam ee pving mia wi siases Memory download reading once downloaded the memory can be treated to obtain patient compuance ana usage aad along with listings and statistics on all saved events Useful medical and technical reports and summaries can be printed from this menu Patient and machine database Monitoring this enables online monitoring of pressure and flow curves with online reading of ventilation parameters inspiratory expiratory and total time tidal volume I T ratio rat pressure you can also save this monitoring to obtain statistics of ventilation over a given selected time COQUITLAM BRITISH COLUMBIA V3K 6V2 TEL 604 540 8288 FAX 604 540 8245 SETTINGS IN PSV PSV ST MODE IPAP inspiratory pressure EPAP expiratory pressure Inspiratory ramp Rise time Inspiratory trigger Exhalation trigger Minimum rate Apnea Time Target VT Maximum pressure to reach Target Vt Monitoring 5 40 Parameters 0 20 4 Levels 5 Levels PENE a 15 to 75 5 mbar 80 of decrease from peak flow Mm 70 af 60 4 40 ome 5 3 305 15 bpm
6. ss to all technical components lt 5 parameters on one single page Dedicated menu for alarms and patient monitoring Possibility of changing the ventilation mode during ventilation Tutorial messages for the user Technical even memorization and reading with direct Possibility of locking display on the LCD screen the parameters Micro turbine with an expected 15000 hrs life time RS 232 communication port for eventual software upgrade online monitoring and memory retrieval patient compliance and ventilation parameters with the Airox communication Package software Maintenance menu allowing several diagnosis and sensor calibration Display of patient and device hour meter on the screen Exhalation Vt Monitoring As an option the Legendair can integrate a monitoring function of the exhaled tidal volume of the patient With the adaptation of exhalation valves of different brands with different set ups The exhalation kit is presented as a mono block for an easy installation and disinfection With the reading of the exhaled tidal volume on the display and the settings of alarms Autonomy The Legendair integrates a Li ion internal battery no memory effect to provide a better portability of the device during ventilation with an autonomy that can reach up to 11 hours It is also equipped with a 24V connection for an eventual external battery Target Vt ewes Cs A Roe Ergonomics Developed in