Home

TAD M-10 - Klassen Brothers

image

Contents

1. M10 Radio Controls PWR VOL Power and volume control SQL Squelch noise control SCAN Channel Scan DISP Display control PRI Priority scan PRG User program control Each of these controls is described in the following section PWR VOL Control The radio is turned on and off by pushing this control Push on push off The audio level from the speaker increases as this control is rotated clockwise SQL Control This controls the receiver silencing circuitry To correctly utilize this control first select an unused channel then rotate it counterclockwise until noise is heard in the speaker and the BUSY indicator shows in the display Now rotate the control clockwise until the noise is squelched and the BUSY indicator goes out on the display This is the most sensitive setting for this control Rotating this control further clockwise decreases the sensitivity of the receiver This is sometimes handy in noisy conditions Channel selector knob Use this control to select a channel Panel Buttons The four front panel buttons perform two functions each The first one is performed when the button is pressed and then released after the first beep The second function is performed when the button is pressed and held in for 2 3 seconds and a second beep is heard 1 When the panel button is pressed and released after the first beep The SCAN button toggles the radio in and out of the scan m
2. it becomes clear Pr plus the priority channel number will be displayed on the display If the mic is taken off hook one of the following will happen depending on how your dealer has set the priority option 1 The radio will always revert to the PRI channel 2 The radio will revert to the priority channel only if the radio is not on a busy channel If the radio is on a busy channel when the mic comes off hook the radio will stay on that busy channel until the mic is placed back on hook USER PROGRAMMING MODE The User Programming contains four separate modes i Bank number select if available ii Priority channel select iii Monitor on off select iv Scan delay select Please Note a To enter User Programming press the PRG button b Once in the User Programming mode use the PRI button to select the desired mode c Inthe Priority channel select and the Bank number select mode use the Channel knob to select a channel or a bank number In any of the other three modes use the DISP button to select the proper function Bank 1 2 3 or 4 The BANK mode in User Programming lets the user select up to four different BANKS IH N of frequencies depending on how the dealer has set up the radio This means that Gee there can be up to 4 times 99 or 396 channels installed in the radio If there are no frequencies installed in a bank it
3. will display CH ALL CLR Th rt Priority Channel Peros May be any valid channel Monitor on off MATIN Pt Ltd Teros been enabled on the channel MON indicator is visible on the display when the function is active HEH Monitor ON defeats tone muting while on hook unless Busy Channel Lockout has Scan Delay 0 3 6 or C es 0 Nodelay the radio will resume scanning as soon as the channel clears 3 3 seconds delay the radio will resume scanning after 3 seconds 6 6 seconds delay the radio will resume scanning after 6 seconds C The radio will resume scanning 3 seconds after the channel has cleared NOTE Each BANK is separate from the others so you cannot scan channels that are in another BANK However you can have separate Scanned channels Priority channel and Scan resume times etc for each BANK Channel Revert Active when the radio is in the scan mode the radio is scanning If the radio is scanning and not on a busy channel when the USER takes the microphone Off Hook the radio will REVERT to the channel that was selected when the scan key was pressed to enter the scan mode This channel does not have to be one of the scanned channels However if the radio hears a signal and stops on a channel and the USER takes the microphone Off Hook before the radio resumes scanning the radio will stay on that channel M10 DIS
4. PLAY MESSAGES Uo g l J Indicates there are no frequencies programmed into this Bank It The radio s PLL is out of lock on the present channel If RX is active no TX is permitted If TX is active the radio will beep and return to RX when the PTT is released Radio requires service Indicates TX Time Out Timer has expired A beep is heard intially then momentarily until PTT is released POWER START UP WARNINGS 00 INVALID Wrong Lock Code entered 01 INVALID Wrong option switch selected or front panel switch is active on turn on or Mic 02 INVALID Front panel switch is active on turn on or Mic 03 INVALID Incompatible software 04 INVALID Invalid PC request 05 INVALID Radio turned off and turned on too quickly Radio s theft protection has been triggered and the code has been entered incorrectly more than 10 times Scan was selected and the mic placed on hook however no channels have been selected to be in scan within the Bank or group Priority function has been selected and the priority channel has become active No Alpha name has been programmed into the channel Display selected with DISP key No Tone has been programmed into the channel Display selected with DISP key ee J SCAN E A PRI BUSY MTI Mt LI MECI M INITIL NE I e
5. function has been activated On when the radio is in scan mode The radio also requires the mic to be on hook and channels programmed into the scan sequence Indicates a received signal has exceeded the squelch threshold Audio will be heard unless a tone is also muting the channel Appears on all channels NOT in the scan sequence Radio is operating in Dealer Programming Mode Radio is operating in User Programming Mode Not used On when the external horn blowing function has been activated MTS versions Active when a CTCSS or DCS tone has been programmed into the channel RX and TX tones are indicated independently RX Used only during Dealer programming TX Appears when the radio is transmitting SCAN MODE When the SCAN indicator is on the radio will scan all the channels that have been entered into the scan sequence whenever the microphone is hung up When the radio comes to a channel that is busy it will stop and stay on that channel for the duration of the scan resume time that has been programmed in the User Programming mode or until the channel becomes clear If a tone is programmed into the RX it must be valid as well unless the Monitor function is on PRIORITY MODE When the PRI indicator is on the radio will continually sample the status of the priority channel If the priority channel becomes busy the radio will beep and stay on the priority channel until
6. ode The SCAN indicator on the display will be on when in the scan mode The DISP button changes the display from channel number an alphanumeric name up to 7 characters to frequency to tone frequency then back to channel number only The PRI button toggles the radio in and out of the priority mode The PRI indicator on the display will be on when in the priority mode The Priority channel may be selected in the User Programming Mode If no priority channel has been selected a double beep will be heard and the indicator will not come on The PRG button puts the radio into the User Programming Mode The U PROG indicator on the display will be on when in the user programming mode 2 When the panel button is pressed and held until the second beep The SCAN A D button adds or deletes the present channel from the scan sequence The D indicator is turned on when the channel is deleted from the scan sequence The channel will not be scanned if it is deleted from the scan sequence When adding or deleting channels it is recommended that you be out of the SCAN Mode thus viewing all the channels in the Group The DISP DIM button toggles the display backlighting between dim and normal The PRI L N button toggles the receiver between normal and low sensitivity The LOW indicator is on when the receiver is least sensitive This is
7. useful in areas where very strong interfering signals are present The receiver is reset to the Normal condition everytime the radio is turned off The PRG button provides access to further programming by an authorized person Dealer MIC connector This is used to connect the microphone to the radio Cloning Plug Used to connect to another M10 radio or to a PC to clone information or program the radio GROUP LOW MON PRI SCAN BUSY D PROG U PROG AUX HORN TONE INDICATORS Frequency Tone Alpha Name Messages Channel Number Messages eS ooo Yt I NA NYA A N WA NZ el DM DAD DALE BR DRE DA GROUP LOW MON PRI SCAN BUSY D O PROG AUX HORN TONE RX TX Feature and Operational Indicators Active when a group of scanned channels have been selected A number above will indicate which group is active Only valid in radios with Group Scan Software During RX operation this indicates the receiver is operating in reduced sensitivity mode to prevent strong signals from overloading the receiver During TX operation this indicates low power has been programmed into the TX of this channel This will only appear when a tone has been programmed into the RX MON will indicate that the muting function of the tone has been disabled This may happen when the mic is taken off hook or by enabling the monitor function On when the priority

Download Pdf Manuals

image

Related Search

Related Contents

  Bedienungsanleitung SSP-800/CT-SSP Surround  HP 600 LV970UT notebook  MLC SUF Gamme 04.12A  Blues bruksanvisning  Micro Innovations PD625P User's Manual  USER GUIDE - ADSL Nation  USER GUIDE IML = ∆ k Q P  Philips SCB5350NB User's Manual    

Copyright © All rights reserved.
Failed to retrieve file