1. Arduino dal 1905 manuale tecnico d uso technical manual Arduino Congratulations you have chosen an unique in its kind machine Read carefully what is advised in the instruction manual for setting up of your ADONIS You will see how easy it is to make delicious coffee and creamy cappuccinos With the passing of time you will also realise how little maintenance is needed Victoria Arduino 43 ADONIS 2 id 141 999 O 6 SG is Q e o N wo i 2 JJ G u Y mS 640 860 5 1325 314 566 649 EM Model ADONIS 2 gruoups Net weight 84 Kg Gross weight 90 Kg Thermal power 4500 W Boiler capacity 14 It Volts 230 380V 50 60Hz Model ADONIS 3 gruoups Net weight 98 Kg Gross weight 108 Kg Thermal power 5000 W Boiler capacity 17 It Volts 230 380V 50 60Hz C The approval mark certifies that all machines have been subjected to accurate inspection tests and checks 45 46 INDEX TECHNICAL CHARACTERISTICS GENERAL REMARKS ON THE CONSIGNMENT SAFETY REGULATIONS DESCRIPTION ACCESSORIES UST ciccia TRANSPORT AND HANDLING APPLIANCE IDENTIFICATION INSTALLATION AND PRELIMINA
2. A09 Single delivery spout 1 1 A10 Coffee presser 1 1 11 Microfibre cloth 1 1 A12 DVD 1 1 A13 Overall 1 1 3 TRANSPORT AND HANDLING 3 1 APPLIANCE IDENTIFICATION When contacting the manufacturer Victoria Arduino for any reason always quote the machine serial number The machine is transported on pallets containing several machines inside boxes secured to the pallet by straps Before performing any transport or handling operation the operator must wear safety gloves and footwear and overalls with elasticised ends Pallets must be transported using an adequate lifting mechanism fork lift truck type CAUTION COLLISION OR CRUSHING HAZARD During the entire handling operation the operator must make sure no one or nothing is inside the operating area Slowly lift the pallet to about 30 cm from the ground and move to the loading area After making sure there are no obstacles persons or things proceed with loading Once at destination always using an adequate lifting mechanism eg fork lift after making sure there is no one or nothing within the unloading area lower the pallet to about 30 cm from the ground and transport it to the Storage area A CAUTION COLLISION OR CRUSHING HAZARD Before performing the following operation make sure the load is in place and is not likely to fall when the straps are cut The operator wearing safety gloves and footwear must now cut the str
3. ENTER key for at least 10 sec onds and wait for the acoustic signal followed by AUTOMATIC CLEANING CYCLE The display will read The central key in each unit 2 will begin to flash on and off Insert the blind filter Fig 2 A06 into the filter holder add half a dose of PULICAFF and attach the filter holder into the unit where you intend to carry out the automatic cleaning cycle It is possible to wash more than one group at the same time 67 68 Press the key to start the unit automatic cleaning cycle The display will read where 1L indicates that the cleaning cycle has been activated within the 1st unit Once the cycle of 15 deliveries of 5 seconds each with a 10 second pause between each delivery has been completed the selected unit key will begin to flash on and off again and the display will read RINSE Eliminate any residues of PULICAFF from the blind filter and press the rinsing cycle starting up key of the unit or units where the cleaning cycle has been effected The letter R will remain on the display like the key e Once the rinsing cycle of the selected unit or units has been completed the display will read PROGRAMMING DOSES The display will read PRODORAN DOS Press ENTER and the display will read DOSES SELELT All the programmable keys will start to flash on and off Press the coffee key you wish to program the dis play will
4. MANUAL SWITCHING OFF Automatic On Off NOT PROGRAMMED SWITCH ON press the RESET key for 2 seconds the buzzer will beep the display will light up to indicate the release of the EPROM for about 1 second The control unit will start up an auto diagnosis cycle to check the functions all the selection keys will light up Once the check is completed the display will read with the day and time When 110 C has been reached the heating message will disappear and will be replaced by the words NOTE On completion of the check up all the selection keys are activated WARNING In case the auto diagnosis indicates error or malfunc tion call an assistance centre the operator MUST NOT intervene POWER OFF press the RESET key for 2 seconds the machine will turn off and the display will read Automatic Off PROGRAMMED The machine will SWITCH ON at the first programmed switch on time see the section entitled PROGRAMMING at the paragraph PROGRAMMING ON OFF The control unit will perform an auto diagnosis of all func tions and all of the selection keys will light up Once the diagnosis is complete the display will read as follows with the date and time Once the temperature of 110 C has been the word Heating will disappear to be replaced by MACHINE READY 4N NOTE Once the auto diagnosis has been completed all the keys are activated WARNING In case the
5. MC Italy T 39 0733 950243 39 0733 950247 Videoconf 39 0733 950201 info victoriaarduino com www victoriaarduino com
6. auto diagnosis indicates error or malfunc tion call the assistance centre the operator MUST NOT intervene The machine will SWITCH OFF at the first time for stop ping the coffee maker see chapter on PROGRAMMING paragraph on PROGRAMMING ON OFF A NOTE the machine can be switched on or off manually as indicated in the previous paragraph 6 2 LED SWITCH ON Switch off the disconnector and set the main switch B to I Fig 15 6 3 BUTTONS KEY Selection Configuration 1 5 1 Long coffee Continuous 47 D 2 Small 2 Long coffees Hot Water Cup Warmer 6 4 STEAM FLOW ADJUSTMENT Use the dial to increase reduce the flow of steam inject ed into the milk as illustrated in the following figure NOTE Before using the steam wand always bleed out any condensation for at least 2 seconds or according to the manufacturer s instructions 6 5 ADJUSTING THE TURBOCREAM NOZZLE If Fitted To increase reduce the amount of air injected into the milk from the TurboCream nozzle and therefore to increase reduce the amount of foam in the heated milk proceed as illustrated in Fig 17 Loosen the stainless steel tube 1 as illustrated in Fig 17 A To increase reduce the amount of air tighten turn ing clockwise or loosen turning anticlockwise the Tefl
7. cup warmer is programmed the s Thedisslavwill read button will flash slowly E Press the ENTER key to pass to the next page Single temperature The display will read Pressing ENTER will cause the display to read for example Using W keys it is possible to increase or reduce the temperature within a certain range 40 C 80 C 104 F 176 F Press ENTER to confirm and pass to the next step Press RESET to return to the previous page without confirming Double Temperature The display will read Using the W A keys it is possible to increase reduce the temperature no 1 within a certain range 40 C 80 104 F 176 Press RESET to return to the previous page without confirming 73 Press ENTER to confirm and pass to the next step the display will read The times will start to flash on and off e Vary the hours and the minutes by using the Using the W A keys it is possible to increase key reduce the temperature no 2 within a certain range Confirm by pressing the ENTER key 40 C 80 C 104 F 176 F Press ENTER to confirm and pass to the next step Once the hours and the minutes have been varied Press RESET to return to the previous page without press ENTER again and vary the day the month confirming and the year by using the same procedure as de scribed above DATE TIME PROGRAMMING On completion press ENTER to go on to th
8. read Followed by the dose amount already set by the manufacturers Vary the dose by pressing the buttons W A By pressing the coffee key you want to program delivery will be started up in the meantime all the other keys will turn off Once you have the required dose press the con tinuous coffee key to stop pouring The display will show the new dose amount which can still be changed by means of the keys W A Press the ENTER key to confirm the programmed dose Press the RESET key to cancel programming The programmed coffee key will switch off Hot Water Press the button and make sure that it lights up The display will read PRODORAN BUSES SECONDS The value X X is the default setting Press the W keys to vary the hot water delivery time Q If a new sampling is desired press the button again Delivery starts When the desired dose has been reached press the button again Q The display will show the new dose value set which still be changed by pressing the W A keys Press the ENTER o passare ad una successiva se lezione per concludere l operazione Press the RESET key to cancel programming The Q button will turn off Timed steam Press the button and make sure it lights up In those models provided with a temperature probe optional the control unit automatically recognizes the presence of the probe and the display will read PRODORAN DOSES STEA TEM xL followed by the
9. C F BAR The display can also show you the pressure or tempera ture status of the boiler to pass from one to the other press the W key on the display In the case of pressure the reading will be shown in bar while for temperature it will be in degrees Celsius or Fahrenheit F The display setting for the tempera ture can be chosen from the setpoint setting page In fact when choosing the temperature mode the setpoint will be shown in degrees Celsius or Fahrenheit accord ing to the chosen measurement ON OFF STAND BY ENERGY SAVING MODE This allows to rotate into the three working modes sta tuses Press RESET for 3 secto switch on gt off gt stand by the machine status 8 CLEANING AND MAINTENANCE 8 1 SWITCHING OFF THE MACHINE To switch the machine off press the main switch and set the machine to the energy position 8 2 CLEANING THE OUTSIDE OF THE MACHINE The machine must be set to power switch off and disconnector open before any cleaning operations are performed WARNING Do not use solvents chlorine based products or abrasives WARNING It is not possible to clean the machine using water jets or standing it in water Cleaning the work area remove the worktop lifting it up from the front and sliding it out Remove the water collection dish underneath and clean everything with hot water and cleansers Cleaning the bottom To clean all the chromium plat
10. FFECT SOLUTION NOTES PRESSURE ERROR When the machine s temperatu re is higher than 130 The display indicator will flash on and off and the resistor is de activated The system will be re establi shed as soon as the temperature goes below 130 The boiler is provided with a ma nual refitting safety thermostat if the resistor is not re established call a qualified technician OVERCURRENT ERR Incorrect electrical input caused by a malfunction in one of the machine charges The display reading will flash The pump will switch off The heating element and all other functions will be disabled Switch off the machine and send for a specialist technical engineer FINE GRINDING The machine registers values different from the set values A much longer delivery time Modify grinding degree press the key RESET or one of the keys W A By leaving the machine in the programming state within 10 minutes from the last selection the system will return to the previous configuration and the display will indicate its reestab lishment of normal functioning COARSE GRINDING The machine registers values different from the set values A much shorter delivery time Press the RESET key or one of the keys W A Arduino Codice 31000336 Edizione 01 del 04 2010 Victoria Arduino Via Madonna d Antegiano 6 62020 Belforte del Chienti
11. HOLDERS Place two spoonfuls of special cleanser in half a litre of hot water and immerse filter and filter holder without its handle in it leaving them to soak for at least half an hour Then rinse abundantly with running water 9 ADONIS MACHINE FUNCTION MESSAGES DISPLAY AND KEY INDICATIONS DIAGNOSIS OF ERROR CAUSE At the time of the diagnosis the system presents faults within the control unit EPROM EFFECT If after 90 sec of machine fun ctioning the water level is not re established SOLUTION NOTES DELIVERY ERROR DOSER ERROR On reaching delivery time limit 120 seconds the doser doesn t send out its set commands If the doser doesn t send out its set commands within the first th ree seconds from delivery onset The display indicator and the continuous key belonging to the relative unit will flash on and off If the delivery isn t manually hal ted the maximum time limit 120 sec will be blocked Press the RESET key or one of the keysW A Press the RESET key or one of the keysW A LEVEL ERROR If after 90 sec of machine fun ctioning the water level is not re established The display indicator will flash on and off The pump is de ac tivated The resistor and all the functions are halted Tum the machine off and then turn it on again All its functions will be re activated 81 82 DISPLAY AND KEY INDICATIONS CAUSE E
12. RY OPERATIONS ADJUSTMENTS TO BE MADE BY A QUALIFIED TECHNICIAN ONLY FILLING BOILER MANUALLY PRESSOSTAT PUMP ADJUSTMENT HOT WATER ECONOMISER ADJUSTMENT 2422 CLOCK BATTERY REPLACEMENT USE TURNING THE MACHINE ON LED SWITCH ON BUTTONS KEY Selection Configuration STEAM FLOW ADJUSTMENT ADJUSTING THE TURBOCREAM NOZZLE If Fitted ADJUSTING THE AUTOSTEAM NOZZLE If Fitted PROGRAMMING PROGRAMMING USER PROGRAMMING TECHNICIAN Mode CLEANING AND MAINTENANCE SWITCHING OFF THE MACHINE CLEANING THE OUTSIDE OF THE MACHINE CLEANING THE STAINLESS COFFEE HOLDERS CLEANING THE UNIT WITH THE AID OF THE BLIND FILTER CLEANING FILTERS AND FILTER HOLDERS MACHINE FUNCTION MESSAGES 1 GENERAL REMARKS ON THE CONSIGNMENT 1 1 SAFETY REGULATIONS 1 The present manual is an integral and essential part of the product and will have to be handed over to the user Read carefully the written warnings in the present manual as they give important suggestions concerning the safety of installation and set up use maintenance Keep this manual in a safe place for further information A POLLUTION DANGER 2 After removing the packaging check the integral parts of the machine are intact If in doubt do not use the machine and contact the professionally q
13. UALIFIED TECHNICIAN ONLY 5 1 FILLING BOILER MANUALLY A NOTE This operation must be carried out with the machine turned off All models A DONIS are equipped with a level gauge to keep the water level inside the boiler constant When using the machine for the first time it is advisable to fill the boiler by hand to avoid damaging the electrical resistor and turning on the electronic protection If this should happen just turn the machine off and then start it up again to complete its loading procedure see chapter MACHINE FUNCTIONS MESSAGE LEVEL ERROR 56 To fill the boiler manually for the first time proceed as follows remove the grid and the drip tray remove the protective metal sheet by unscrewing the two side screws A as shown in the following illustration turn the manual A level tap so that water will enter the boiler after about 45 seconds shut off the valve A as illustrated in the following figure switch on the machine see the chapter SWITCHING ON THE MACHINE 5 2 PRESSOSTAT PUMP ADJUSTMENT the pump registration screw turning it clock set pump pressure is displayed in the pressure wise to INCREASE and counter clock wise to gauge inside the machine see Fig 11 A NOTE DECREASE the pressure This operation can be carried out while the machine is turned on To adjust the service pressure of the boiler thus regulat ing th
14. aps and store the product To perform this operation check the technical characteristics of the prod uct to determine the weight of the machine to be stored and take consequent precautions A CAUTION POLLUTION HAZARD Once the machine has been freed of the pallet or con tainer do not discard these in the environment pollution hazard 53 54 4 After unpacking assess that the machine and its accessories unit are complete then proceed as fol lows place the machine so that it is level on a flat sur face assemble its supporting feet by inserting the insert into the cylindrical unit see Fig 3 twist the rubber foot into the screw thread inside the unit see Fig 3 screw the whole assembled unit into the allotted setting for the machine s adjustable feet level the machine by regulating the adjustable feet A NOTE The unit grooves have to face upwards as shown in the following illustration INSTALLATION AND PRELIMINARY OPERATIONS Fig 3 Q It is advisable to install a softener 1 and then a mesh filter 2 on the external part of the plumbing system dur ing preliminaries and after levelling the machine In this way impurities like sand particles of calcium rust etc will not damage the delicate graphite surfaces and durability will be guaranteed Following these operations connect the plumbing sys tems as illustrated in the following f
15. ater and steam keys will start to flash Pressing one of the flashing keys will show the cor responding counter on the display Press the A key to return to the previous function Press the RESET key to quit the display mode TOTAL The display will read TOTAL The short coffee key of each group will flash and when pressed the machine will show the number of coffees poured with the given group Press the W A keys to view the other functions Press the RESET key to quit the display mode MACHINE TOTAL The display will read Press the W A keys to view the other functions Press the RESET key to quit the display mode WASH COUNT The display will read The long coffee key for each group flash and when pressed the display will show the number of wash cycles carried out for that particular group Press the W A keys to view the other functions Press the RESET key to quit the display mode LIST OF PROGRAMMABLE FUNCTIONS TECHNICIAN Mode AUTO CLEAN CYCLE DOSE PROGRAM DELIVERY COUNT ON OFF PROGRAM ENERGY SAVING CUP WARMER PRO DATE TIME POURING TIME SETPOINT PRESS HISTORICAL ALARM MAINTENANCE LANGUAGE TEMPERATURE LIGHT ADJUST Operation to be carried out EXCLUSIVELY by a Qualified Technician Adjustment by NON quali fied technicians can invalidate the guarantee 7 3 PROGRAMMING TECHNICIAN Mode To enter the Technician Mode programming environ ment hold down the
16. case the machine has remained unutilised for a long time the clock can be blocked by proceeding as follows with the machine off the display will read OFF press the ENTER key for 5 seconds the display will read The clock will start up again as soon as the machine is plugged in once more WARNING Replacement of the lithium battery must be carried out EXCLUSIVELY by Qualified Technician Nuova Simonelli cannot be held liable for any damage to people or things due to non observance of the safety prescriptions described in this booklet 59 60 6 USE Before starting to use the appliance the operator must be sure to have read and understood the safety prescriptions contained in this booklet The ADONIS model is equipped with a display key T and a technical key U With the display key T it is possible to access the normal operating functions While programming menus can be seen but not modified Chapter 7 The technician U key allows you to access all the func tions and to modify the parameters of the programming menu 6 1 TURNING THE MACHINE ON Switch off the disconnector and set the main switch A to I The unlit display will read Fig 14 NOTE The machine is not operative in that the main switch only supplies the electronic card WARNING For electronic card maintenance turn the machine off by means of the external main switch or disconnect the plug
17. e carrying out any maintenance operation unplug the socket after having switched off the machine switch 11 bis For the cleaning operations bring the machine to energetic state O that is to say machine is switched off and socket unplugged and keep exclu sively to what is stated in the present manual In case of breakdown wrong functioning of the machine switch it off Any intervention is strictly forbidden Contact exclusively professionally authorised personnel The possible repair of the products will have to be made by the manufacturer only or by an authorised service using exclusively original spare parts Non compliance with the above stated can compromise the safety of the machine When setting it up the licensed electrician will have to check an omni polar switch is provided by the actual safety regulations with opening distance from the contacts the same or bigger than 3 mm To avoid dangerous overheating we do recommend you uncoil the supply cable to its full length bis user mustn t replace the supply cable of this machine In case of damage switch the machine off and for its replacement contact exclusively profes sionally qualified personnel In the event that you decide not to use a machine of this kind anymore we advise you make it ineffective by unplugging the socket then cut the supply cable WARNING DANGER OF POLLUTION Do not dispose of the machine in the e
18. e next The display will read page PROGRAMMING THE POURING TIME The ADONIS model is equipped with an elec tronic system to control delivery times according to By pressing the ENTER key the display will read for the coffee grinding fineness example 74 The display will read When the ENTER key is pressed the display will read Using the W A keys it is possible to select XXX as NOT ACTIVE pouring times will not be shown ROW 1 pouring times will be shown in row 1 ROW 2 pouring times will be shown in row 2 Press ENTER to confirm and pass to the next step Press RESET to return to the previous page without confirming If the delivery time display is on when a delivery is started unless with the Continuous function the bottom line of the display will show the delivery time or times if more than one unit is delivering Each group has an area of the bottom line the area on the left is for unit 1 the area alongside it is for unit 2 and so on until the area on the far right which is for unit 4 The different areas are separated by vertical bars if a group is not delivering the area is empty Here below is an example unit 1 is delivering it has just started and 0 seconds have passed unit 2 has been delivering for 12 seconds and unit 4 is deliver ing it has been delivering for 21 seconds Area reserved to the Area reserved to the delivery time of unit 2 delivery time of unit 3 Area
19. e water temperature according to the various func tions and needs of the coffee desired proceed as follows remove the grid and the drip tray remove the protective metal sheet by unscrewing the two side screws A as shown in the following illustration Advisable pressure 9 bar At the end of the adjustment process refit the sheet metal guard on the relevant housing and secure it in place with the two side screws Refit the drip tray and the work surface grid 58 5 3 WATER ECONOMISER ADJUSTMENT NOTE This operation can be carried out while the machine is turned on All models ADONIS are equipped with a hot water mixer tap which adjusts the water temperature and optimises the system s performance To adjust the hot water economiser turn the registration knob The hot water economiser is located inside the machine To access the economiser remove the cup warm er section on the left by loosening the two screws D as illustrated in the following figure Turn the adjustment knob ANTICLOCKWISE CLOCKWISE to INCREASE REDUCE the tempera ture of the hot water when the operation has been completed screw the protective panel back on 5 4 CLOCK BATTERY REPLACEMENT The electronic control unit is equipped with a lithium bat tery to provide the clock with an approximately three year autonomy period after which replacing the battery may prove necessary In
20. ed areas use a soft damp cloth 8 3 CLEANING THE STAINLESS COFFEE HOLDERS The stainless coffee holders are situated under the delivery units as shown in Fig 21 NOTE To clean proceed as follows Tum the screw placed in the centre of the holder Slide the coffee holder out and check that its holes are not obstructed but clean f obstructed clean as described Paragraph CLEANING FILTERS AND FILTER HOLDERS We recommend cleaning the coffee holder once a week 79 80 8 4 CLEANING THE UNIT WITH THE AID OF THE BLIND FILTER The machine is pre set for cleaning the delivery unit with a specific washing powder The machine will initiate washing cycle which consists in the circulation of hot water followed by regular breaks We recommend carrying out a washing cycle at least once a day with special cleansers A CAUTION RISK OF INTOXICATION Once the filter holder has been removed repeat deliv ery operations a few times to eliminate any cleanser residues To carry out the washing procedure proceed as fol lows Substitute the filter with the delivery unit blind filter Fill it with two spoonfuls of special cleanser pow der and insert it into the unit filter holder Press one of the coffee keys and halt it after 10 seconds 4 Repeat the procedure several times 5 Remove the filter holder and carry our a few deliver ies 8 5 CLEANING FILTERS AND FILTER
21. electrotechnical wastes or to give it back to the seller or dealer when buying a new equipment of equivalent type in terms of one to one The suitable separate waste collection for the following sending of the disused equipment to recycling the dealing or handling and compatible environment disposal contributes to avoid possible negative effects on the environment and on the people s health and helps the recycling of the materials the machine is composed of The user s illegal disposal of the product implies the application of administrative fines as stated in Law Decree n 22 1997 article 50 and followings of the Law Decree n 22 1997 2 DESCRIPTION ADONIS Delivery Unit Buttons LCD Display Select Buttons Electric Cup Warmer Hot Water Steam Programming Keys Adjustment Dial Steam Flow Hot Water Nozzle Autosteam Nozzle Piede Regolabile WX ON A Delivery Unit Manual Steam Nozzle Filter Holder Cup Rack Drip Tray 73 Machine Main Switch Fig 1 51 52 2 1 ACCESSORIES LIST 7 a J 4S L ti Fig 2 CODE DESCRIPTION 2 GROUPS 3 GROUPS A01 Filling tube 1 1 Worktop draining tube 025 Bep 180 cm i A03 Filter holder 3 4 A04 Double filter 2 3 A05 Single filter 1 1 A06 Blind filter 1 1 A07 Spring 3 4 A08 Double delivery spout 2 3
22. erating conditions leaving it in a state in which it is ready for operation The device is then switched off and the whole hydraulic circuit is bled of the first lot of water in order to remove any initial impurities The device is then refilled and taken to rated operating conditions After reaching the ready for operation condition the following dispensing operations are carried out 100 of the coffee circuit through the coffee dispenser for more than one dispenser this is divided equally 100 of the hot water circuit through the water dis penser for more than one dispenser this is divided equally opening of each steam outlet for 1 minute At the end of installation it is good practice to draw up a report of the operations The use of any electrical device must comply with fundamental regulations In particular do not touch the machine with wet hands or feet do notuse the machine barefoot do not use extensions in places used as a bath or shower do not pull the supply cable to disconnect the machine from the supplying net do not leave the machine exposed to atmospheric agents rain sun etc do not allow the machine to be used by children or by non authorised personnel that haven t read and understood this manual During installation the mains power system needs to be equipped with a disconnector switch to cut off each phase 11 The authorised technician has to befor
23. igure WARNING Recommended mains pressure for the water is 2 6 bar WARNING Avoid throttling in the connecting tubes Assess that the drain pipe 3 is able to eliminate waste 3 E i an m IZ 2 Mesh filter Drain 9 50 mm NOTE a correct functioning of the machine the water works pressure must not exceed 4 bars Otherwise install a pressure reducer upstream of the softener the internal diameter of water entrance tube must not be less than 6mm A CAUTION RISK OF SHORT CIRCUITS The machine must always be protected by an automatic omnipolar switch of suitable power with contact open ings of equal distance or more than 3mm Nuova Simonelli is not liable for any damage to peo ple or objects due to not observing current security measures Prior to connecting the machine to the electrical mains assess that the voltage shown on the machine s data plate corresponds with that of the mains If it does not carry out the connections on the basis of the available electrical line as follows for V 380 3 phases voltage Neutral Fig 5 for V 230 monophase vo KEY CD Black Q Grey Brown Blue 5 Yellow green 55 5 ADJUSTMENTS TO BE MADE BY Q
24. leaning cycle AUTOMATIC CLEANING CYCLE Carrying out a cleaning cycle in more than one unit LCD Display The display will show at a time is possible 2 RESET Key to turn the machine on and off and to exit menu CURSORS Key to scroll the menu and 4 to increase decrease values ENTER Key to access the menu The central key in each unit Qi begin to flash on and off Insert the blind filter Fig 2 A06 into the filter holder add half a dose of PULICAFF and attach the filter holder into the unit where you Press the key to start the unit automatic cleaning cycle The display will read 65 where 1L indicates that the cleaning cycle has been activated within the 1st unit Once the cycle of 15 deliveries of 5 seconds each with a 10 sec ond pause between each delivery has been completed the selected unit key will begin to flash on and off again and the display will read RINSE Press the RESET key to view the next functions or to quit the display mode DOSES The display will read USES Press the ENTER key and all of the dose hot water and steam keys will start to flash Pressing one of the flashing keys will show the cor responding programmed setting on the display Press the A key to return to the previous function Press the RESET key to quit the display mode POURING COUNT The display will read Press the ENTER key and all of the dose hot w
25. mit or the set maintenance date have been reached the display will visualize the message To remove the MAINTENANCE message move the date forward or increase the number of coffees SELECTING THE DESIRED LANGUAGE The display will read Press the ENTER key to visualise the language al ready set Choose the desired language by using the W A Press ENTER to confirm and pass to the next step Press RESET to return to the previous page without confirming TEMPERATURE UNITY MEASURE SELECTION The display will read By pressing ENTER the display will read TEMPERATURE Press W A to modify the measures unit setted Press ENTER to confirm and pass to the next step Press RESET to return to the previous page without confirming KEYBOARD LIGHTING ADJUSTMENT The display will read pressing ENTER key the display will read With the 45 light X blinking select the value of desired brightness choosing from a minimum value of 1 to a maximum of 6 by using the W A keys Confirm by pressing ENTER The temperature 2 52 value blinks and with A keys it is possible to set the 2 52 5 lighting from a minimum value of 1 to a maximum of 3 Press ENTER to confirm and pass to the next step Press RESET to return to the previous page without confirming ENTER THE HIDDEN FUNCTIONS This allows to enter other special functions In BRIGHTNESS ADJUST mode hold down
26. nvironment for waste disposal contact a specialised authorised centre or contact the manufacturer that will give you informa tion about this To help the of the machine place it 15 cm from the walls or from other machines on the aeration side WARNING DANGER OF BURNING When using the vapour pay much attention and do not place hands under it and do not touch it immediately after its use 18 Remember that before carrying out any set up oper ation maintenance download or tuning the qualified operator has to wear working gloves and safety shoes The maximum noise disturbance level is lower than 70db 20 the pipe connecting to the mains water is replaced the old pipe must never be re used WARNING INFORMATION TO THE USERS Under the senses of art 13 of Law Decree 25th July 2005 n 151 Implementation of the Directives Guidelines 2002 95 CE 2002 96 CE and 2003 108 CE concerning the Sa reduction of the use of dangerous substances in electric and electronic equipment as well as the disposal of wastes The symbol of the crossed large rubbish container that is present on the machine points out that the product at the end of its life cycle must be collected separately from the other wastes The user for this reason will have 49 50 to give the equipment that got to its life cycle to the suit able separate waste collection centres of electronic and
27. on tube 2 as illustrated in Fig 17 B Tighten the stainless steel tube again NOTE By reducing or increasing the length tightening or oosening the tube Teflon tube by a few fractions of a mm mm there is a significant difference in the amount of foam in the heated milk 6 6 ADJUSTING THE AUTOSTEAM NOZZLE If Fitted To increase reduce the amount of air injected into the milk from the TurboCream nozzle and therefore to increase reduce the amount of foam in the heated milk proceed as illustrated in Fig 18 Loosen the stainless steel tube 1 as illustrated in Fig 18 A To increase reduce the amount of air tighten turn ing clockwise or loosen turning anticlockwise the Teflon tube 2 as illustrated in Fig 18 B Tighten the stainless steel tube again 63 Fig 18 4 far as concerns temperature settings see the relevant programming section 64 NOTE By reducing or increasing the length tightening or loosening the tube Teflon tube by a few fractions of a mm mm there is a significant difference in the amount of foam in the heated milk 7 PROGRAMMING 7 1 KEY 7 2 PROGRAMMING USER Mode Press ENTER and the display will read To enter the user mode display environment hold down the ENTER key for 8 seconds and wait to hear the first acoustic signal The machine will read ADONIS 6 a Fig 19 intend to carry out the automatic c
28. out confir mation STANDARD DOSES When the display reads we mean to recall the standard dose values Press the W key The display will read At this point the continuous coffee keys will begin to flash Select one or more continue keys the key or keys selected will remain lit up The key or keys will recall the selected unit s stand ard doses Press the ENTER key to confirm The display will read By pressing the ENTER key the display will read To access the automatic cleaning counter press ENTER The long coffee keys the machine will begin to flash when the group key is pressed the display will show the number of wash cycles carried Allthe delivery keys will start to flash on and off By out Hold down the RESET key for 3 seconds to Press the RESET or the A key to exit without con pressing one of the delivery keys the amount of the reset firmation deliveries made will be visualised NOTE all the selections can be programmed for a Hold down the RESET key for 3 seconds to reset PROGRAM ON OFF mum of two minutes after that time a flashing NOTE The continuous coffee equals one delivery message will appear on the display saying ERRUR display will read Press W key and the display will read DELIVERY COUNT This indicates the total amount of deliveries made The display will read Hold down the RESET key for 3 seconds to reset By pres
29. reads LOW POWER USE STANDBY 0 50 bar during STANDBY the machine maintains a pressure of 0 50 bar and the display set to minimum brightness reads LOW POWER USE STANDBY 0 80 bar during STANDBY the machine maintains a pressure of 0 80 bar and the display set to minimum brightness reads LOW POWER USE This type of operation is possible when switching the machine on off manually using the RESET key and when switching the machine on off automatically using the ON OFF programming function If the RES key is pressed while the machine is in one of the standby conditions 0 10 bar 0 50 bar 0 80 bar the machine switches to OFF If the key is pressed again the machine enters the ON mode Press the ENTER key to confirm the mode selected from the display and go back Press the RESET key to go back without confirming CUP WARMER PROGRAMMING The display will read The message ON XX will begin to flash use the W keys to change the cup warmer open time from In the cup warmer section of the list of programmable 0 to 60 min hidden functions see page 77 itis possible to select Press ENTER to confirm and pass to the cup warm one of the following types of cup warmer single tradi er OFF time from 0 to 60 min tional single temperature double temperature NOTE Setting one of the two ON OFF values to 0 will Pressing ENTER will open the submenu automatically bypass the function Single Cup Warmer When the
30. reserved to the Area reserved to the delivery time of unit 1 delivery time of unit 4 SETTING THE SET POINT PRESS The set poin point allows to chose the pressure tem perature in the working status When the ENTER key is pressed the display will read Press W A to adjust the work press temp point Press ENTER to confirm and pass to the next step Press RESET to return to the previous page without confirming Bar 0 50 0 55 0 60 0 65 0 70 0 75 0 80 0 85 0 90 0 95 1 00 1 05 1 10 1 15 1 20 1 25 1 30 PRESSURE TEMPERATURE TABLE ADONIS C 110 5 111 5 112 5 113 5 114 115 115 5 116 5 117 5 118 119 119 5 120 5 121 122 112 5 123 F 230 9 232 7 234 5 236 3 237 2 239 239 9 241 7 243 5 244 4 246 2 247 1 248 9 249 8 251 6 252 5 253 4 15 76 1 35 124 255 2 1 40 124 5 256 1 1 45 125 257 1 50 126 258 8 1 55 126 5 1 60 127 HISTORICAL ALARM VISUALISATION The display will read By pressing the ENTER key the display will read ERROR Ll Pressing the W key allows you to scroll down the ten previous alarms saved in the memory After the tenth alarm by pressing the W key again you can go on to the next page MAINTENANCE PROGRAMMING The display will read MAINTENANCE E UAI 771 NNUARS 2000 Usethe A keys to set both values Use the ENTER key to confirm Once the set delivery li
31. sing the W key the display will read where the ON and OFF values indicate when the machine will turn on and off 71 72 Press W A to change the day forward and back ward Press ENTER to vary the programmed starting up time the message ON 07 30 will start to flash on and off Use the W A keys to vary the starting up time Press ENTER to confirm and to go on to the pro grammed switching off time the message OFF 23 30 will start to flash on and off Use the W keys to vary the switching off time Confirm by pressing ENTER To de activate the on off function on weekly day off press RESET The display will read BAY OFF to reinstate press RESET After the word SUNDAY by pressing W again a beep will signal that you have come to the following page ENERGY SAVING stand by The display will read SAVINO This function allows the machine to enter an active STANDBY status where it is possible to choose whether to switch off the machine completely or to keep it at a set pressure lower than working pressure Press ENTER and the display will read ENERGY SAVING AYATA Here it is possible to select the XXX mode using the keys The 4 operating modes are OFF during STANDBY the machine is switched off and the display reads OFF STANDBY 0 10 bar during STANDBY the machine maintains a pressure of 0 10 bar and the display set to minimum brightness
32. temperature set previously by the manufacturer Press the W A keys to vary the temperature of the beverage you want to heat When the desired tem perature has been reached the steam delivery will automatically stop In the standard version without temperature probe on pressing the the display will read PRODORAN DOSES STER SEL followed by the amount already set by the manufac turers Press con the W A keys to vary the steam delivery time If a new sampling is desired press the 0 button again Delivery starts When the desired dose has been reached press the button again o The display will show the new value set which can still be changed by pressing the W A Press the ENTER key or go on to a further selection to terminate the operation Press the RESET key to cancel programming The button will turn off TRANSFERRING DOSES When the display reads PROGRAM DOSES SELELT CSI 69 70 transferring the set dose to other units is possible by pressing the W key The display will read at this point the continuous coffee keys of the second third and fourth groups will flash as shown in Fig 20 Selecting the continuous key the key will stop flashing and remain lit will transfer the values programmed for the first group to the other groups one at a time Press the ENTER key to confirm At this point the display will read Press the RESET or A key to exit with
33. ter for human consumption bis This machine must be installed according to the applicable federal state and local standards codes in force with regard to plumbing systems including back flow prevention devices For this reason the plumbing connections must be car ried out by a qualified technician 5 The device needs to be supplied with water that is suitable for human consumption and compliant with the regulations in force in the place of installation The installation engineer needs confirmation from the owner manager of the system that the water complies with the requirements and standards stated above 47 48 This machine will to be used only for the purpose described in this manual The manufacturer can t be considered responsible for possible damage caused by improper wrong or unreasonable uses WARNING Before using the machine read carefully and completely the instruction manual safety regulations and the machine tuning directions Q This appliance is not suitable for use by children or persons with reduced physical sensory or mental capabili ties or by persons with a lack of experience or knowledge unless supervised or given instructions 0 The maximum and minimum storage temperatures must fall within a range of 5 50 C 0 bisThe operating temperature must be within the range of 5 35 C At the end of installation the device is switched and taken to rated op
34. the 1 long coffee keys of the FIRST amp SECOND group for at least 3 sec to open the special menu Now the buttons are for RESET to exit hidden menu A UP DOWN to change the parameters ENTER to surf the hidden menu Programmable hidden functions list Self level with pump no pump UP DOWN to switch Self level sense 1 2 3 UP DOWN to switch Hot water with pump no pump UP DOWN to switch Level in delivery not active active A UP DOWN to switch Temperature calibration 15 0 15 C F A UP DOWN to switch Pressure calibration 200 0 200 mbars UP DOWN to switch Pre brewing not active active UP DOWN to switch TT 78 Cup single single temp double temp UP DOWN to switch Clock calibration 300 0 300 sec month UP DOWN to switch Serial connection active not active UP DOWN to switch Least group 0 1 2 3 W A UP DOWN to switch Least serve 0 1 2 3 W A UP DOWN to switch DIRECT LINKS In machine ready state you can go direct to the set tings below instead of surfing the menu SETTING THE TEMPERATURE POINT Press ENTER A to go directly to the Setting Point menu this will be bars or C F depend on the status view you were Y A press UP or DOWN to move up and down the working Point Press ENTER to confirm and pass to the next step MONITORING UNIT
35. ualified personnel The elements of the packaging must be kept out of children s reach as they can be potential sources of danger and they mustn t be disposed of in the environment 3 Before connecting the machine make sure that the data of the plate correspond to those of the electrical distribution network The plate is located under the machine s base The installation has to be carried out in compliance with the regulations of the Country where the machine is set up according to the instructions by the manufacturer and qualified personnel The manufacturer can t be considered responsible for possible damage caused by failure in earthing the plant For the electrical safety of this machine it is obligatory to arrange the earthing plant contact an electrician with proper and certified technical suitability to check the electrical capacity of the plant is adequate to the maximum power of the machine stated on the plate In particular the electrician will have to make sure that the section of the plants cables is suitable to the power absorbed by the machine The use of adaptors multi sockets and extensions is forbidden If their use is necessary it is compulsory to call a licensed electrician When installing the device it is necessary to use the parts and materials supplied with the device itself Should it be necessary to use other parts the installa tion engineer needs to check their suitability for use in contact with wa