Home

PR Strobe Can User Manual

image

Contents

1. RELIABILITY STROBE CAN PR 2288 This product manual contains important information about the safe installation and use of this luminaire Please read and follow these instructions carefully and keep this manual in a safe place for future reference PR LIGHTING LTD No 571 Yingbin Road Dashi Panyu Guangzhou 511430 China http www pr lighting com INDEX SAFE USAGE OF THE LUMINAIRE INSTALLING THE UNIT FITTING THE LAMP DEDICATED CONTROLLER MODE MAINTENANCE KEEPING THE UNIT CLEAN TROUBLESHOOTING TECHNICAL DATA ELECTRICAL DIAGRAM Oonnw 1n kt BW Pp Please note that as part of our ongoing commitment to continuous product development specifications are subject to change without notice Whilst every care is taken in the preparation of this manual we reserve the right to change specifications in the course of product improvement The publishers cannot be held responsible for the accuracy of the information herein or any consequence arising from them Every apparatus is tested completely and packed properly by the manufacturer Please make sure the packing and or the apparatus is in good condition before your installation and use Should there be any damage caused by transportation consult your dealer and do not use the apparatus But any damage caused by improper use will not be assumed by the manufacturer and or dealer ACCESSORIES THESE ITEMS ARE PACKED TOGETHER WITH THE UNIT Mounting Bracket 1 PCS M6 Knob
2. DATA Power supply 230V AC 50Hz Optional 240V 220V 120V AC 50 60Hz Power consumption 30W at 220V Lamp 16W BH 0647 Manufactures Rated Lamp Life 250 Hours Strobe speeds 1 17 F P S Adjustable Signal Analogue signal Running mode Stand Alone mode Dedicated Controller PR 1388 or PR 1389 mode Dimensions 240mm LONG x 200mm WIDE x 200mm HIGH Including Bracket 240mm LONG x 245mm WIDE x 260mm HIGH Net weight 1 5kg N L AC PLUG 9 Ho m SPEED POT INPUT OUTPUT FUSE F 2A 250V gt LAMP lt gt PR LIGHTING LTD No 571 Yingbin Road Dashi Panyu Guangzhou China Post Code 511430 TEL 86 20 8478 1888 FAX 86 20 8478 6023 P N 320030041 Last Revision 10 04 2004 6 6 Strobe Can manual doc
3. c FITTING THE LAMP Align the Boss and Slot Lamp Holder r First remove the front cover and then plug the lamp into the lamp holder When installing hold the screw part of the lamp and let the slot of the lamp align the boss of the lamp holder before plug the lamp completely Note Never touch new lamps with your bare fingers use a tissue or a cloth Before removing blown lamp ensure that the unit is sufficiently cool The BH 0647 is high voltage lamp Care should always be taken when handling these lamps Always read the manufacturers Instructions for use enclosed with the lamp DEDICATED CONTROLLER MODE You can use the controller PR 1388 and PR 1389 produced in our company to control many luminaries The dedicated controller PR 1388 and PR 1389 are optional for the customers For detail about the controllers please refer to relative user s manual AUDIO PLUG CONNECTING Connecting the controller with the luminaire and the luminaire with the luminaire is the audio plug cord It is shown in the figure below AUDIO PLUG CONNECTION 4 6 Strobe Can manual doc CONNECT THE CONTROLLER AND UNITS Connect the controller s output to the first fixture s input and connect the first fixture s output to the second fixture s input The rest may be deduced by analogy No 1 No 2 Audio Cord Audio Cord Si
4. er run the luminaire without a lamp There are no user serviceable parts inside the unit do not open the housing and never operate the unit with the covers removed Always disconnect from the mains when the device is not in use or before cleaning it or before attempting any maintenance work If you have any questions don t hesitate to consult your dealer INSTALLING THE UNIT Front Cover Bracket Fixing Hole Safety Chain a Strobe Speed ak x ooo Control lt lt We Ke j Hole for Fixing Secondary Safety Chain Input Output vel Signal Socket Power Cord Front Cover Locking Knob This unit has been designed to be hung Mount the bracket provided on the body of the unit by 2 M6 locking knobs provided then suspend the unit via its bracket using a M10 size bolt through the fixing hole When you want to adjust the angle of the body of the unit you only loosen the two M6 knobs carefully and then adjust the angle of the body After finishing that it is recommended that you don t forget to retighten the two knobs Always ensure that the unit is firmly positioned to avoid vibration and slipping and always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 1 5Kg for each Strobe Can For safety the unit and the front cover should have secondary fixing with a safety cable through the hole as shown in the figure above 3 6 Strobe Can manual do
5. for mounting bracket 2 PCS Dedicated controller PR 1388 or PR 1389 Optional This manual 1 PCS INTRODUCTION Thank you for purchasing the product Strobe Can PR 2288 The Strobe Can adopts advanced design and manufacturing and it complies to CE norms and standards The cover is made from high intensity and heat resistant complex plastic The structure design is simple and portable The unit is convenient to be hung and the angle of the body is easy to be adjusted The Strobe Can may be used as a stand alone unit or linked to a dedicated controller The strobe speeds of the luminaire may reach 20 flashes per second and the strobe speeds can be adjusted so it is suitable for use in stage disco night club artistic applications and so on SAFE USAGE OF THE LUMINAIRE When unpacking and before disposing of the carton check there is no transportation damage before using the unit Should there be any damage caused by transportation consult your dealer and do not use the apparatus The unit is for Indoor use only IP20 Use only in dry locations Keep this device away from rain and moisture excessive heat humidity and dust Do not allow contact with water or any other fluids or metallic objects The projector is not designed or intended to be mounted directly on to inflammable x surfaces The unit is only intended for installation operation and maintenance by qualified personnel High voltage Inside the luminaire Avoid shock haza
6. gnal CONTROLLER PR 1388 or PR 1389 MAINTENANCE If the lamp becomes damaged or deformed in any way it must be replaced If the light from the lamp appears dim this would normally indicate that it is reaching the end of its life and it should be changed at once old lamps run to the extremity of their life can explode If the luminaire does not function check the fuse on the main PCB inside the unit it should only be replaced by fuse of the same specified value 2A 250V fast blow 5mmx20mm Should it be damaged call a qualified technician before replacement Any maintenance work should only be carried out by a qualified technician KEEPING THE UNIT CLEAN Cleaning frequency depends on the environment in which the fixture operates damp smoke or particularly dirty surroundings can cause greater accumulation of dirt on the unit s optics A soft cloth and typical glass cleaning products should be used in cleaning It is recommended to clean the reflector at least once every 20 days Do not use any organic solvent e g alcohol to clean the housing of the unit TROUBLESHOOTING PROBLEM RESOURCE The luminaire does not start Check the power fuse is blown or not Check if the lamp is good or not The luminaire switches on but does not Check the audio cable is good answer to commands The beam appears dim Check the lamp is not at the end of its life 5 6 Strobe Can manual doc TECHNICAL
7. rd The unit must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Do not project the beam onto inflammable surfaces minimum distance is 3m 3m 2 6 Strobe Can manual doc Avoid direct exposure to the light from the lamp The light is harmful to the eye Do not attempt to dismantle and or modify the luminaire in any way Electrical connection must only be carried out by qualified personnels Before installation ensure that the voltage and frequency of power supply match the power requirements of the unit It is essential that each unit is correctly earthed and that electrical installation conforms to all relevant standards Do not connect this device to any dimmer pack Make sure that the power cord is never crimped or damaged by sharp edges Never let the power cord come into contact with other cables Only handle the power cord by the plug Never pull out the plug by tugging the power cord The luminaire can not be used continuously over 15 minutes under maxmum speed The lamp used in this projector is a discharge and high voltage lamp After being switched off don t attempt to restart the projector until lamp has cooled this will require approx 15 minutes Switching the lamp on and off at short intervals will reduce the life of both the lamp and the projector But occasional breaks will prolong the life of the lamp and projector Nev

Download Pdf Manuals

image

Related Search

Related Contents

今 、エネ EMS ルギー Sの導入 ー供給に 入と拡大 に    KOSA USER MANUAL USER MANUAL  ANGEL V HANGER 取扱説明書くお客様用)  Samsung 32" F6100 6. seeria SMART 3D Full HD slim LED TV Kasutusjuhend  Dissertação mestrado_Joana Vieira  WP-900 Hydro-Bloc Membrane Imperméable et Membrane  Minolta CF1501 Copier  Documentation technique - comptoir  MODE D`EMPLOI  

Copyright © All rights reserved.