1. L 302 06 12       Thinking ahead  Focused on life  MORITA    TwinPower Turbine   Maintenance Guide  D Disinfection         1 P  l    r   Aa         MANUAL  Lubrication   Cleaning    Chuck Lubrication  3 Seconds of Spray        AUTOMATED  Lubrication   Cleaning          Chuck Lubrication  5 Seconds   Beep Sounds        Turbines may fail quickly if  maintenance is not performed  consistently or correctly             Handpiece Lubrication          Perform these maintenance fLubrina 3 Seconds of Spray  procedures after treatment Handpiece     RER   gt  Lubrication  and before autoclaving  aec toria  Wipe Off  Excess Lubricant Minimum of  15 Seconds of  Operation  Wipe Off  Excess Lubricant  G  Sterilization  1  Cleaning e Remove bur from handpiece   e Remove cutting debris  blood  and other contaminants with a soft brush and running water     Do not fail to wash off all chemical  electrolytic  and other active liquids  Only    2  Disinfection e Use gauze or a soft brush with disinfecting alcohol on the entire handpiece  LJ  e Handpieces with the following mark may be cleaned and disinfected with a thermal washer and disinfector         To use a thermal washer and disinfector  do not fail to follow the instructions and conditions that come    with the handpiece     3  Lubrication  a  Manual  Lubricate with AR Spray   Cleaning e Lubricate the chuck and the handpiece with AR Spray for 3 seconds each  La      e Operate the handpiece for a minimum of 15 seconds to remove excess lubric
2. ant  1     e Wipe excess lubricant off the surface of the handpiece  A    AN   Use the proper nozzle for type of handpiece joint        Chuck Spray Nozzle Handpiece Connection    Do not press down on the push cap of the handpiece during operation     b  Automated  Lubrina with AR Spray   e Perform chuck lubrication using Lubrina s built in Chuck Nozzle     Line up the front end of the head with the nozzle guide and set the chuck in place     Lift the handpiece up slightly to begin cleaning and lubricating for about 5 seconds  beep sounds    e Attach handpiece to its coupling with the chuck facing back     Select Station 1 4     Wipe excess lubricant off the surface of the handpiece   A   Refer to the user s manual on how to operate Lubrina        4  Sterilization e Place the handpiece in a sterilization pouch and autoclave at 135   C  275   F  for a minimum 135  C  of 5 minutes of sterilization time  Ta  A   Autoclave and drying temperatures must not exceed 135   C  275   F    5  Storage   Remove the handpiece from autoclave unit and store carefully   NOJS e Wear surgical gloves to perform maintenance     e Use AR Spray only     e See user s manuals for details      www morita com usa 1 888 JMORITA  566 7482     
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Elke Loeffler_Defining Quality_FRENCH version  Fender SR-6520PD DJ Equipment User Manual  Sony DPP-SV88 Photo Printer User Manual  Forum Phone 315 Mode d`emploi    Copyright © All rights reserved. 
   Failed to retrieve file