1. 3 Detergent disinfectants should not be mixed with other germicides or detergents Using the proper dilution ensures the most effective killing power of the disinfectant Always follow the disinfectant manufacturer s instructions 4 Wash hands often and well including after removal of gloves paying particular attention to around and under fingernails and between fingers Control Unit Cleaning Wipe off dust If necessary clean the housing exterior with a disinfectant solution or a mild detergent and a damp cloth Then wipe dry DO NOT HEAT OR STEAM AUTOCLAVE THE CONTROL UNIT Filter Cleaning amp Maintenance Check the air filter on the rear of the unit on a monthly basis for the buildup of dust dirt If buildup is visible turn off the blower then remove the filter by grasping the filter and pulling Replace with a clean filter Ensure the replaced filter covers the whole filter region Hand wash the removed filter in warm soapy water and allow to air dry When dry store the filter in a safe place for the next filter maintenance WARNING Do not put a moist filter back in the unit Do not operate the unit without a filter Doing so could result in permanent damage to the system www accuromedical com 17 Serenity Support Surface Manual Mattress Cleaning The Serenity mattress top cover and bottom covers are both designed to prevent any moisture from entering the inside of the mattress Both the top cover and the bottom c
2. EE N 11 ELA E E E E ree T A ee ee 11 Patient Safety RailS ans eGGSA EG RE Ge ee ER RD ee ee 11 LS OE EE EE N EE DE 11 Comfort Adjustment Up amp Down ButtONS esse ss sesse ee 12 Ese ae iN OR ELE EE ET 12 WIRELESS REMOTE CONTROL seen ne seeks eee bees se ee ei ed see ei 12 13 Using the Wireless Remote Control ss ss esse Es de EE EE ee 12 Remote Control BUIS ves EEUE ENGER NERENS EE OER DE Ge Soe Gee 13 Reritole State iewe ie Ge Ee EEN EN ee 13 BT EL EE EE EE te 13 OTHER FEATURES ss ee dienian an pe pes ee ee ser ees eie ee 13 14 EE DEE ER A TR ET EN 13 Power FailureSYSter iss or se EE Gegee RR ei Ge REG ee es NG 13 14 esse RE RE OE EA 14 Emergency EVaeualiO is sarsie aa ed Es Ge GE AG Re ERG 14 aie reid RE EO EE EE ORR 14 ALARMS ME EE OE N EE EN 15 16 CHECK HOSE CORINEC TOR ses ens sgessee se ee ee Ee ee 15 POWER FAILURE oes ee sora sect ede ee Ge ei ee oe ed ee ee ee ie DEd 15 NON THERAPEUTIC RANGE esse iese eon se sie GE Ee ee RE Ge ie 16 CLEANING AND MAINTENANCE esse ss ss see ee ee ee ee ee see se se ee ee ee ee ee ee de Ge 17 20 GENERAL CLEANING GUIDELINE Si sss osse gees ase ese ie ei ees ee died 17 CONTROL UNIT CLEANING osse dees n esse ee ee ee EE Ee ee Gie ee 17 FILTER CLEANING amp MAINTENANCE ese ese sesse ss es ee ee ee ese ee ee se se se ee ee 17 MATTRESS CLEANING osse oe ns ese ee ee ee ees Ee ee ie 18 TOP SHEET CLEANING ese ese Reed Ee ie se er Rage Re ee bes Re GE eer 19 Light Cleaning of Topshieet
3. be sent back C O D using the shipper of your choice Warranty service in the United States can be obtained during the warranty period from Accuro Medical Products LLC Please call 800 669 4757 to obtain a return authorization number RA number No product will be accepted for return without an RA number Shipping The purchaser is responsible for shipping costs incurred returning defective product to Accuro Medical Products LLC Accuro Medical Products LLC will pay all shipping costs in curred in returning repaired or replacement parts to the purchaser Limits and Exclusions There are no express warranties except as listed above The warrantor does not warranty the merchantability or fitness of this product for a particular purpose THIS WARRANTY DOES NOT COVER NORMAL WEAR AND TEAR OR DAMAGE WHICH OCCURS IN SHIPMENT OR FAILURES WHICH ARE CAUSED BY PRODUCTS NOT SUPPLIED BY THE WARRANTOR OR FAILURES WHICH RESULT FROM ACCIDENT MISUSE ABUSE NEGLECT MISHANDLING MISAPPLICATION ALTERATION FAULTY INSTALLATION MODI FICATION OR SERVICE BY ANYONE OTHER THAN THE WARRANTOR OR DAMAGE THAT IS ATTRIBUTABLE TO ACTS OF GOD THE WARRANTOR SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THIS PRODUCT OR ARISING OUT OF ANY BREACH OF THIS WARRANTY ALL EXPRESS AND IMPLIED WARRANTIES ARE LIMITED TO THE APPLICABLE WARRANTY PERIOD SET FORTH ABOVE www accuromedical com 23 ine Therapeutic Mattress S
4. most circumstances it is not recommended to permanently mute the Alarms and should only be done when absolutely necessary 10 amp 11 Comfort Adjustment Up amp Down Buttons This is a micro adjustment that fine tunes the softness and firmness of the mattress There are thirteen choices six that are firmer six that are softer and one that is no adjustment The unit powers up at no adjustment 2 e Press either Comfort Adjustment button The current setting is displayed next to the buttons e To increase the firmness press the up button To decrease the pressure press the down button GO Lock Out The lock out function is turned on or off at the time of manufacturing If not requested the unit is built with this function disabled This function is used to lock the keyboard so that settings are not accidentally changed The lock out function automatically activates after 10 minutes of inactivity When the Lock Out function is engaged the Power On light begins to flash indicat ing Lockout is enabled for 3 To Unlock and make adjustments to the settings press and hold the Power Key seconds Wireless Remote Control The Wireless Remote control allows the patient to change e Comfort Adjustment e Low Air Loss Therapy e Alternating Pressure Therapy e Alternating Pressure Therapy Cycle Time e Patient Safety Rails e Max Firm e Deflate Using the Wireless Remote Control To use the Wirele
5. 2 2 No 601 1 Risk Class 2G Note UL Classification refers to Power Unit only not complete mattress replacement system www accuromedical com Serenity Support Surface Manual Safety Instructions 1 To avoid damaging the Serenity control unit be sure the power available at your location matches the power call out on the rear of the Control Unit i e 110VAC USA 220VAC Europe Australia To avoid electric shock always plug the Serenity Control Unit into a properly grounded receptacle If you are uncertain if the outlet you wish to use is grounded have the outlet inspected by a licensed electrician Do not spill food or liquids onto the Serenity Control Unit If a spillage does occur dis connect it from its power supply and allow at least 24 hours for drying During the drying time other arrangements must be made to meet the patient s clinical needs Do not insert items into any openings of the Serenity Control Unit Doing so may cause fire or electrical shock by shorting internal components Keep unit away from radiators or other heat sources Be sure nothing is placed on the power cable and ensure it is not located where it can be stepped on or tripped over Do not attempt to service the Control Unit except as explained in this guide Always fol low installation and servicing instructions closely WARNING Service and repair must only be performed by an authorized Accuro Medical Products LL
6. C Technician ig Therapeutic Mattress Systems Quick Start Instructions 1 Remove the existing mattress from the bed and store it 2 Unroll the Mattress with the hose connection at the foot of the bed with the nylon side up 3 Secure the ten 10 straps securely to the bed frame Being careful not to impede the moving parts of the bed frame 4 Hang the Serenity Control Unit on the foot of the bed facing away from the bed Attach the hose connector to the Control Unit 5 Plug in the Control Unit power cord The yellow Standby light will illuminate 6 If you are going to use the Adjustable Air Loss Therapy Sheet apply it at this time 7 Ifthe patient is being transferred from a wheelchair or standing position he she should be placed on the bed at this time If the patient is being transferred onto the surface in a laying position he she can be placed on the bed at this time or after the system is fully inflated 8 Press the Power Key The Unit starts and the Green On light illuminates mattress can be inflated with patient on the mattress 9 Select the appropriate weight range 10 The rapid inflate cycle will start automatically The mattress will quickly inflate to the appropriate pressure This is based on the weight range selection and the comfort setting 11 If you want to reposition the patient or to transfer the patient onto the surface in a laying position press the Max Inflate key The sur
7. asy to use Serenity is the first alternating pressure low air loss mattress replacement system specifically designed to ad dress the needs of the hospice patient Offering many more comfort settings than other air mattress systems is one way that the Seren ity is able to address the complex comfort needs of the hospice patient Serenity will allow the user to adjust the comfort setting well below the softest setting of most systems The system will also allow the user to make the surface much firmer than most air systems With four choices of alternating pressure and four choices of alternating pressure cycle times the user is able to find a combination that will provide just the right amount of therapy resulting in superior comfort Having four options for direct and indirect low air loss therapy helps control moisture on the patient s skin surface You can adjust the air flow to the level that will control the moisture while not cooling the patient When used in the Therapeutic Ranges the Serenity is suitable for the care and prevention of all stages of pressure ulcers as well as patients that have been assessed to be at high risk from the complications of immobility This high quality medical product if properly used and cared for will provide many years of trouble free service and outstanding clinical performance for all of your patients weighing between 70 and 350lbs Serenity replaces the standard mattress on most long term care and h
8. at you do not have adequate space a turning schedule should be implemented immediately and the patient should be transferred to another surface as soon as possible www accuromedical com 13 Serenity Support Surface Manual during a power failure the system will deflate and cannot be re inflated until CAUTION If the hose connector is disconnected from the control unit the power is restored To ensure the patient is protected you should perform a hand check every four to six hours to ensure that the system is providing adequate pressure relief If at any time you determine there is less than two fingers worth of air under the patients buttock he she should be transferred to another surface as soon as possible and a turning schedule initiated immediately Transport To transport the patient on the mattress with the mattress attached to the bed frame Press the power button placing the Unit in Standby Unplug the Unit the mattress will hold air during the transport Secure the power cord When the transport is complete plug the Unit in and press the power button to enter the Run mode To transfer the patient on the mattress to another bed frame Max inflate the mattress Inflate the patient safety rails Remove the mattress straps from the bed frame Place the new bed frame next to the old bed frame making sure the top of the two bed frames are even Place the mat tress blower in standby Unplug the mattress blower and place gently bet
9. e Once power is restored the system will return to the settings that were selected prior to the power failure www accuromedical com 15 Serenity Support Surface Manual Non Therapeutic Range The Non Therapeutic Range light indicates that the Serenity is operating outside of the com monly accepted pressure relief setting The Serenity Mattress Replacement System is designed specifically to provide comfort to the end of life patient and therefore will allow the user to select settings that are not providing pressure relief The following are the combinations that will cause the system to operate outside of the accepted pressure relief ranges e Selecting one of the top three Comfort Settings with the Alternating Pressure Setting in the Static mode e Selecting one of the top three Comfort Settings along with either the 12 15 or 20 minutes Alternating Pressure Cycle Times e Selecting one of the bottom three Comfort Setting with the Alternating Pressure Setting on the Static or Low settings could result in the mattress being so soft the patient could potentially bottom out Bottoming out is when there is less than one inch of air under the patients bottom and the bed frame e Selecting the High Alternating Pressure Setting with either the 12 15 or 20 minute Alternating Pressure Cycle Times CAUTION It is important to keep in mind that certain combinations of therapy modes will allow the system to operate at pressures that are n
10. e is the default Alternating Pressure Cycle for all settings and the only cycle time available for the High setting To change the setting e Press the Cycle Time button The current setting is displayed next to the button e Keep pressing the Cycle Time button to select the desired Alternating Pressure Cycle Time therapy modes will allow the system to operate at pressures that are not providing pressure relief therapy This is indicated on both the front of the unit and on the remote with the non therapeutic range light being illuminated When this lamp is illuminated the system is not providing continuous pressure relief and care should be taken to ensure the patient is frequently turned to avoid the development of pressure ulcers CAUTIONS itis important to keep in mind that certain combinations of 5 Low Air Loss Adjustment This function is used to adjust the Air Loss Therapy It requires the use of the optional Air Loss Top sheet When the unit powers up the Air Loss feature is set to Off There are four levels of Air Loss Therapy Off Low Medium and High Each level adjusts the amount of air that is released into the Top sheet e Press the Low Air Loss button The current setting is displayed next to the button e Keep pressing the Low Air Loss key to select the desired level of Low Air Loss therapy 6 Deflate This function is used to deflate the entire mattress without unp
11. enity control unit CAUTIONS Do not use in the presence of smoking material or open flame Air flowing through the mattress will support combustion N Care should be taken to not allow patients whose mental state is such that making decisions about the delivery of the therapy provided by the Serenity could result in an adverse outcome to have access to the wireless remote control Risk of electric shock do not remove the back cover of the control unit Refer all service to qualified service personnel It is important to keep in mind that certain combinations of therapy modes will allow the system to operate at pressures that are not providing pressure relief therapy This is indicated on both the front of the unit and on the remote with the non therapeutic range light being illuminated When this lamp is illuminated the system is not providing continuous pressure relief and care should be taken to ensure patient is frequently turned to avoid the development of pressure ulcers IMPORTANT The AC power cord acts as the main disconnect for this device N Emergency Deflate is accomplished by disconnecting the hose connector from the control unit www accuromedical com Serenity Support Surface Manual Introduction Thank you for purchasing the Therapeutic Mattress Systems Serenity Mattress Replacement System manufactured by Accuro Medical Products LLC The Serenity mattress replacement system is quiet comfortable and e
12. face will quickly become very firm The max inflate cycle will last for 12 minutes or until the Max Inflate key is pressed again 12 If the patient is being transferred onto the bed in a laying position he she should be transferred at this time 13 Inflate the Patient Safety Rails 14 Select an Air Loss Therapy Mode 15 Select an Alternating Pressure Therapy Mode 16 Allow the unit to operate for several minutes prior to changing the Comfort Adjustment INFORMATION It is recommended that you only change the Comfort Adjustment one level every few minutes This allows the system to equalize AN www accuromedical com 9 Serenity Support Surface Manual Detailed Explanation of Functions 310 350 Ibs Oes fos non therapeutic range patient weight O check filter i heck h Es Serenity Se CS 6 1 Power 7 Max Inflate 2 Patient Weight 8 Patient Safety Rails 3 Alternating Pressure Adjustment 9 Alarm Mute 4 Alternating Pressure Time 10 Comfort Adjustment Up 5 Low Air Loss Adjustment 11 Comfort Adjustment Down 6 Deflate Keypad Functions 1 Power Button Turns the Serenity on and off The Standby indicator light glows yellow when the unit is plugged into the main electrical supply but is not turned on e To activate the unit press the power button The yellow Standby light will turn off and the green On light will illuminate e To turn the unit off press t
13. g should be done at least once a week or if the top sheet becomes soiled such as with food medication or other non human waste materials and can be easily cleaned e Don protective gloves e Wipe soiled area using detergent disinfectant e Turn Air Loss therapy on high and allow Top sheet to dry completely before returning the patient to the mattress Deep Cleaning of Top sheet If support surface becomes grossly soiled or becomes soiled with body substances e Don protective gloves protective apparel and eye protection device e Remove patient from surface e Remove any visible bodily substance from surface and dispose of per facility protocol e Remove the top sheet from the mattress e Remove the hose from the top sheet e Place the top sheet in a standard household clothes washer e Wash with warm water standard laundry soap and one cup of bleach e Either air dry or dry in standard household clothes dryer on NO HEAT www accuromedical com 19 Serenity Support Surface Manual Between Patients Cleaning Procedure Don protective gloves protective apparel and eye protection device Prepare detergent disinfectant reg by EPA as hospital disinfectant solution according to manufacturer s instructions for correct use dilution Mattress e remove any visible bodily substance from surface and dispose of per facility protocol e remove Top sheet from mattress e with the system inflated thoroughly wipe down the enti
14. he power button The green On light will go off and the yellow Standby light will turn on 2 Patient Weight Button f Used to select patient s weight f os e Press the Patient Weight key The Weight setting is displayed next to the button e Keep pressing the Patient Weight key to adjust the weight setting to match the patient s weight range 3 Alternating Pressure Adjustment This changes the pressure profile of the alternating pressure cycle When Off is selected the mattress is in static pressure relief mode In this mode the mattress provides continuous pressure relief Low indicates a low level alternating pressure This mode provides gentle pressure changes on an eight 8 minute cycle Medium indicates a moderate level of alternating pressure This mode provides moderate pressure changes on an eight 8 minute cycle High indicates aggressive alternating pressure therapy loading and unloading the tissue on an eight 8 minute cycle e Press the Alternating Pressure button The current setting is displayed next to the button e Keep pressing the Alternating Pressure key to select the desired alternating pres sure profile 10 ig Therapeutic Mattress Systems 4 Alternating Pressure Cycle Time This function is used to select the length of time between Alternating Pressure Cycles You can select between 8 12 15 or 20 minutes The 8 minute cycl
15. inet Therapeutic Mattress Systems serenity Mattress Replacement System Owners and Operators Manual Serenity Support Surface Manual Table of Contents Be ER EE EE AO EE 3 WARNINGS EE EE AE EE EE EE EO AE 3 CAUTION S a EE EE EE EE EE EE 3 MAIPOR TAN EE N EE RE NE EE EE 3 DSTO UIE TICs N AE EE NR EE N 4 SYSTEM CONTROL UNIT FEATURE Swwescnssnssiesesstazexciiesntsssoosssiapdannceedenscetatestizess 5 MATTRESS FEATURES sones oes nie eene ee Oe RE ENE Ee EA oe 6 SYSTEM SPECIFICATIONS lt 0 vas see oes ERG EE Es ERG DR EA ERG EE Oe OOR Ie EE ee Ee Ee 7 ENVIRONMENTAL CONDITIONS wcbssscteasccanceonsecasertsecentansacneresacsipbeakesnersenmeweost 7 AGENCY APPROVALS os tenien ein eer kanse ese ee Ge ee Ee ee Re Ge EE 7 SAFETY INSTRUETIONS 2 nessies ese ERG Ee Ges De EEE ER ER OE DE REG GE 8 OUICK STAR THINS TRUGTIONS es ss ooste be ie ER ee oe EN 9 DETAILED EXPLANATION OF FUNCTIONS asses sesskse sees n dese seed eke Ge de 10 14 KEYPAD FUNCTIONS siese sea Er ie ee Eier andre seen oes ee 10 12 Power BUON sisie sees Ee DEE GEN EE SE DE GR GE Ee SE Ee Ne ee 10 Patient Weig ht sessessessescceesseecocsseessecoosseeecesssesessosseeceeessesseeose 10 Alternating Pressure Adjustment seeseseesssssseresssssssessreeeereressssssss 10 Alternating Pressure Cycle Time scccscsssessonnnessesssoenseanensees 11 Low Air Loss Adjustment ssssssesssssssssessssseerrssssescessssseeeesssseeesss 11 TT AUS eine ccs A E A E A E AT
16. lugging the unit or using the CPR deflate e Press the Deflate button The unit will immediately start deflating e To re inflate to the previous settings press the Deflate button again 7 Max Inflate This function is used to rapidly inflate the mattress or to make the mattress very firm for in bed procedures The system will return to the previous mode settings after 12 minutes e Press the Max button to activate this feature e To turn Max Inflate off press the Max button again 8 Patient Safety Rails Patient Safety Rails are used as an additional safety feature that will help prevent pa tients from falling out of bed They add a full 3 inches to the height of the side bolsters above the mattress surface The Patient Safety Rails will help to reduce the need for side rails e Press the Patient Safety Rail button to inflate the Patient Safety Rails e To deflate the Patient Safety Rails press the Patient Safety Rail button 9 Alarm Mute Alarm Mute is used to either temporarily or permanently mute the Serenity Alarms X This is normally done to allow the provider to correct alarm conditions e Press the Alarm button to mute for 30 minutes Press and hold for 3 seconds to per manently mute all alarms until the unit is put in Stand By mode or the Alarm Mute button is depressed and held for 3 seconds www accuromedical com 11 Serenity Support Surface Manual CAUTION In
17. ome care bed frames Its low friction low shear top cover interface pressures below capillary closure and many therapy options ensure that Serenity will meet your clinical needs The wireless remote control allows those patients that are in a clear mental state to make adjust ments to the system while lying on the mattress This makes transfers and comfort adjustments much easier It also allows the patient to adjust his her therapy when appropriate Care should be taken to not allow patients whose mental state is such that making these types of adjust ments could result in an adverse outcome to have access to the remote control Please take the time to read the contents of this manual before using the system and retain it for future reference gd Therapeutic Mattress Systems System Features CONTROL UNIT FEATURES e Compact lightweight power unit is quiet with robust features e Patient weight capacity 70 350 Ibs e Individual Patient Weight Settings e Thirteen Comfort settings e Four alternating pressure modes e Four Air Loss therapy modes e Rapid system inflation e Max Inflate auto firm function with automatic return to therapy mode e Auto deflate e Patient position sensor optimizes support when the head of the bed is elevated e Wireless remote control e Reusable air filter e Integrated carrying handle for portability e Crisp easy to read graphics for intuitive setup and therapy control e A
18. ort Surface Manual Notes ig Therapeutic Mattress Systems Warranty This warranty is extended only to the original purchaser and does not affect statutory rights Accuro Medical Products LLC the warrantor warrants the Mattress Components see below to be free from defects in materials and workmanship for a period of three 3 years covering all materials and labor costs If within such warranty period the product shall be proven to the warrantor s reasonable satisfaction to be defective it shall be repaired or replaced at warran tor s option warrantor s sole obligation and your exclusive remedy under this warranty being limited to such repair or replacement Mattress Components Mattress base air sacks hosing and mattress covers are warranted for three years from the original date of purchase In the event of a defect in materials or workman ship the items will be replaced with new soft goods in exchange for the defective product Top sheet Top sheets are warranted for a period of ninety 90 days from the original date of purchase In the event of a defect in materials or workmanship the items will be replaced with new Top sheet in exchange for the defective product If the product is deemed by the warrantor not to be covered under warranty a quote will be sent to you for your approval before work will begin If you do not want the work performed a minimum charge of 45 will be charged and your product will
19. ot providing pressure relief therapy This is indicated on both the front of N the unit and on the remote with the non therapeutic range light being illuminated When this lamp is illuminated the system is not providing continuous pressure relief and care should be taken to ensure the patient is frequently turned to avoid the development of pressure ulcers 16 ig Therapeutic Mattress Systems Cleaning and Maintenance The Serenity is designed to keep bodily fluids out of the inside of the mattress Follow facil ity protocol with respect to cleaning between patients cleaning if the surface becomes soiled cleaning while in use Use the same cleaning schedule protocol for the Serenity mattress system that you use for your standard hospital mattresses If at any time you are concerned that bodily fluids have penetrated the exterior of the mattress contact Accuro Medical Products LLC for further instructions WARNING Disconnect the power cord from the wall outlet before attempting to replace the filter or clean the control unit General Cleaning Guidelines 1 Patient care equipment that does not come in contact with mucous membranes or non con tact skin requires low level disinfection Wiping surfaces with a properly prepared detergent disinfectant carries out low level disinfecting 2 Processing of dirty patient care equipment should take place in an area away from clean or sterile supplies and food preparation areas
20. ou use lithium batteries for extended battery life Use of rechargeable batteries is not recommended as they could cause damage to the wireless remote To replace the batteries remove the battery cover on the back of the remote by loosening the Philips style screw and opening the cover Remove all four of the old batteries and replace with new ones Other Features CPR The hose connection at the Control Unit is marked CPR Disconnect the hose from the Con trol Unit Initiate organization s CPR procedures To re inflate the mattress re attach the hose to the Control Unit Power Failure System The Power Failure System that is incorporated into the Serenity Mattress Replacement System helps to ensure that pressure relief therapy is maintained if power is lost to the unit In the event of a power failure the pressure is equalized in the mattress During a power failure it is recommended that the patient s head of the bed be lowered to the flat position to help keep interface pressures as low as possible If the patient has medical conditions that make this unsafe or impractical hand checks should be done every two hours to ensure the patient is not bottoming out To perform a hand check unzip the top cover from the mattress slide one hand between the cushions directly under the patient s buttocks You should have at least two fingers width of space between the buttock and the bottom of the mattress If your hand check revels th
21. over of the mat tress can be wiped down with a disinfectant solution or a mild detergent using a damp cloth Mattress should be dry before the patient is placed back on the mattress If support surface becomes soiled such as with food medication or other non human waste materials and can be easily cleaned e Don protective gloves e Wipe soiled area using detergent disinfectant e Dry with a clean cloth or towel If support surface becomes grossly soiled or becomes soiled with body substances e Don protective gloves protective apparel and eye protection device e Remove patient from surface e Remove any visible bodily substance from surface and dispose of per facility protocol e Using an approved disinfectant cleaner wipe down the entire mattress Follow manufactures guidelines on proper use of disinfectant cleaner e Remove and dispose of gloves and protective apparel per facility protocol e Return patient to surface 18 ig Mattress Systems Top Sheet Cleaning The Adjustable Air Loss Top sheet is designed to allow a variety of air loss therapies to the pa tient and therefore will allow liquids to penetrate the surface The materials that the Top sheet is made out of are antibacterial in nature The Top sheet should be replaced or cleaned if it becomes soiled If used on an extended period of time the Top sheet should be replaced or deep cleaned on a monthly basis Light Cleaning of Top sheet Light cleanin
22. re mattress surface following detergent disinfectant manufacturer s instructions Normally there is no need to clean internal components as the outer cover is water proof e allow all components to air dry e wrap mattress in plastic and return to storage area Control Unit e Thoroughly wipe down outside of control unit and allow to air dry e remove the filter by grasping the filter and pulling e replace with a clean filter Ensure the replaced filter covers the whole filter region e cover control unit with plastic and return to storage area Top sheet e remove the hose from the Top sheet e place the Top sheet in a standard household clothes washer e wash with warm water standard laundry soap and 1 cup of bleach e either air dry or dry in standard household clothes dryer on NO HEAT 20 D Therapeutic Mattress Systems Storage and Care Control Unit After disinfecting the unit as outlined above Accuro Medical recommends that it be placed in a plastic bag for dust resistance and then stored in the Mattress Cart or other clean area used to store electromechanical medical devices Support Surface After disinfecting the mattress gently roll it up use the attached straps to secure it Accuro Medical recommends that it be placed in a plastic bag for dust resistance and then stored in the Mattress Cart or other clean area used to store electromechanical medical devices www accuromedical com 21 Serenity Supp
23. ss EENS SE KEN NE Ee 19 Deep Cleaning Of Top sheet sissies EER BEE EE Se DA BR AE EER ED Ke 19 BETWEEN PATIENTS CLEANING PROCEDURE cccccecceeeeeeneeeeeees 20 STORAGE AND E ARE esse Oo ee ie Boe ge ee 21 WARRANTY EE EE EE EET EE OE EN 23 u Therapeutic Mattress Systems DANGER N Explosion hazard Do not use in the presence of flammable gases AN WARNINGS The cover of this product is not air permeable and may present a suffocation risk It is the responsibility of the caregiver to ensure that the patient can use this product safely Do not use the Serenity control unit in the presence of flammable gases e g anesthetic agents Possible explosion hazard if used in the presence of flammable anesthetics Ensure that the Serenity mattress is securely attached to the bed frame prior to use Care should be taken to ensure that the straps do not interfere with the normal operation of the bed To reduce the risk of entrapment of the patient between the mattress and the bed frame make sure that the mattress is securely attached to the bed frame and any space between the headboard footboard and the mattress is less than two inches at any point If side rails are used with the Serenity mattress care must be taken to reduce the risk of entrapment of the patient Make sure that any space between the side rails and the mattress is less than two inches Never drop or insert any object into the opening on the Ser
24. ss Remote Control face the back of the remote the black side towards the back of the control unit Press the buttons on the remote and the change is indicated on the remote the adjustment will take a few seconds to go into effect The patient should wait for several minutes between comfort adjustments allowing the system to accomplish each adjustment completely The remote will not work when off to the side or in front of the control unit the remote sensor is in the back of the control unit is such that making decisions about the delivery of the therapy provided by the Serenity could result in an adverse outcome to have access to the wireless remote control CAUTION Care should be taken to not allow patients whose mental state 12 ig Therapeutic Mattress Systems Remote Control Buttons Each of the buttons on the remote function the same way the corresponding buttons do on the control unit To make an adjustment press the corresponding button one time You will see the LED for that function change To continue to make additional changes keep pressing the but ton Wait after each button press to see the LED change on the remote Remote Standby The Wireless remote will go into standby mode if no buttons are depressed for 10 minutes All LEDs will go blank This is done to conserve battery life To wake the unit up press any button one time Batteries The wireless remote uses four AA batteries It is recommended that y
25. ted side bolsters that provide a firm side to the mattress that helps to reduce the risk of patient falls e Integrated patient safety rails reduce your patient s risk of a fall by adding an additional 3 inches of side bolster above the mattress surface Patient Safety Rails can be inflated or deflated with the push of a button e Automatic pressure equalization system supports the patient in the event of a power failure for approximately 24 hours e Emergency Evacuation handles allow patients to be evacuated on the support surface gd Therapeutic Mattress Systems System Specifications Weight Control Unit ee EE eN Ee 14 5 IDs 6 6 Kg PPA G CS Ns Re EG Ee eg 23 5 IDs 10 6 Kg Max patient wers DC ss REKE EER eres 350 Ibs 160 Kg Dimensions Control Unit 16 W x 12 H x 7 D in 40 x 30 x 18 cm Mattress es VER 36 W x 80 H x 10 D in 91 x 203 x 25 cm Electrical Specifications SE EE A Europe Australia TVS VAAG OO HE saans contest 220V 240V AC 60 50 Hz MR EE 2A Equipment Symbols Refer to user manual SN Serial Number CE Mark CE Environmental Conditions Operating Conditions Ambient Temp ratUte sa ENE SS Ge 10 C to 40 C Relative Humidity 30 to 75 Non Condensing Storage and Shipping Conditions Ambient Temperature ie RR Re 10 C to 40 C Relative Hume se Ee naan 10 to 100 Agency Approvals UL Classified Medical Equipment UL 60601 1 Can CSA C2
26. utomatic panel lockout to prevent tampering Note This is an optional feature and must be requested at time of ordering e Audible and visual power fail alarm e Audible alarm mute e Integrated hanging brackets that automatically adjust to footboards up to 2 thick e Quick disconnect mattress connection allows for rapid setup and CPR deflate at the control unit www accuromedical com Serenity Support Surface Manual Mattress Features e Serenity provides pressure relief therapy to patients from 70 to 350 pounds e The easy to clean and ultra low maintenance design makes the system ideal for ownership e The eight inch deep air cells allow the system to operate at very low pressures which enhances the ability of the system to provide very low interface pressures e The durable non slip vinyl bottom cover of the mattress protects internal components while being very easy to clean Nylon attachment straps ensure the stability of the mattress on the bed frame e The low friction low shear waterproof top cover of the mattress prevents contamination of internal components while providing a shear and friction reducing laying surface e Serenity s Air Loss Top sheet delivers four levels of both direct and indirect low air loss providing outstanding moisture management e Four Alternating Pressure settings allow you to select the therapy that works best for each patient e CPR deflation in less than 60 seconds e Integra
27. ween the patients legs Make sure all power cables are not tangled up Pull the mattress across to the new bed frame Secure all straps Hang the blower on the foot of the bed plug in and turn on Emergency Evacuation To use the Serenity as an evacuation device Inflate the Patient Safety Rails Max Inflate the mat tress remove the straps from the bed frame power unit off unplug the unit from wall power place the control unit on the mattress use the handles on the sides of the mattress to remove the mattress from the bed and evacuate the patient If necessary you can use gate belts to secure patient to mattress Care must be taken when posi tioning the gate belts to prevent injury to the patient Power should be restored to the Serenity as soon as possible so that therapy can be resumed therapy The unit should be plugged in and power restored as soon as CAUTION During evacuation Serenity is not providing pressure relief possible Ground Pin The Serenity control unit has a conveniently located ground pin This pin is used to conduct ground testing To use the ground pin plug the control unit into the test device place the ground test lead in contact with the ground pin and read the results on the test device 14 D Therapeutic Mattress Systems Alarms The Serenity mattress replacement system monitors several functions and will alarm if the system detects a condition that is effecting the normal operation of the s
28. ystem There are both visual and audible alarms Please refer to the following explanation of alarm conditions and follow the instructions provided to correct the condition If the problem persists contact Accuro Medical s customer service department at 1 800 669 4757 Check Hose Connector The Check Hose Connector alarm will sound if the system detects a leak This is determined by the microprocessor if the system is unable to maintain the expected pressures during operation The most common reasons for this alarm condition are e The hose connector is not properly attached to the control unit To correct this alarm condition disconnect the hose connector for the control unit re align the slot in the connector with the key on the control unit turn turn e One of the tubing connector O rings is damaged or missing in the hose connector Disconnect the hose connector from the control unit Make sure that there is an O ring on each of the four white tubing connectors Do this by looking inside the hose connector If any of the O rings are damaged or missing then replace N CAUTION Only use O rings supplied by Accuro Medical Products LLC e If the alarm condition cannot be corrected as outlined above contact Accuro Medical Products LLC for further advice Power Failure The Power Failure alarm will sound whenever the unit is running and loses power The alarm will sound and the power failure light will illuminat
29. ystems Accuro Medical Products LLC 2854 Hitchcock Avenue Downers Grove IL 60515 Phone 800 669 4757 www accuromedical com 6 12 Rev C UPC 84635400539