Home

(KR-8218G) User Guider - Sunsky

image

Contents

1. 0 00 2002 0eneen eee ee 22 8 Troubleshooting 0 02 200 nen nn en nnn nen nnn n enn n enn en ne en cen nee en en neeen een eee 23 Identification Section Control Panel Receiver and control center of alarm system Remote Control Applied to switch the status of arm disarm stay and for emergency alarm Need to learn to the control panel first Detector Install detector in the detection area sent alert to host once detector was triggered Such as PIR detector door sensor gas detector smoke detector etc Need to learn to the control panel first Arm Any detectors were triggered host alarm Disar m System alarms only when the detectors in emergency defense zone and help senior defense zone were triggered Detectors in other defense zone triggered will not alarm Stay Arm System alarm only when detectors in stay defense zone were triggered Other defense zones not Alarm number Number dialed when host alarm Centre number Upload information to Centre number when host alarm Assistance number Number dialed when detector in help senior defense zone was triggered SMS number SMS message sent to telephone number when host alarm Voice Call Host can be used as an normal mobile phone Delay for system arm When user set the alarm system in the status of arm by remote control or keyboard control panel will delay a period of time for arming Time of delay for alarmin
2. 13 5 8 3 Add detector 2 022 2 n nen ne enn n 13 5 8 4 Delete detector 220 22 en nn en nen een n een e enn e enn nn enn neen eens 13 5 9 Set delay for system arm 2000 0202 en seen nen ne en ne ne en nen e ence nen eens 13 5 10 Set the alarm system password 13 5 11 Set Password modification 13 5 12 Set keyboard password protection feature 00 0 0022 14 5 13 System voice volume adjustment 2 20 20 nen nn en nee n een e ee 14 5 14 Set system voice ON or OFF 2 00 22 2 2n ene nnn en ne nn nn nen en nen n nen nen nen cans 14 5 15 Set the external alarm volume 14 5 16 Set the internal alarm volume 14 5 17 Set length of Siren sound 2 00 02 220 en neeneen nee neen ene nnen nen eens 14 5 18 Set number of ring tones for remote 0 200 002 n nen een e ene 14 5 19 Set the anti tampering of telephone cord ON OFF 14 5 20 Set the SMS Messaging reply ON
3. 2 2 2002 20n nse en nn nnn en nen eee n enn n enn en nes 16 5 33 1 Setting CID event codes 220 202 00 en nen ne en nen e ence een ne nen neeees 16 5 33 2 Set siren ON OFF when Arming 0 0 2002202 n een n nen nen ene enens 16 5 33 3 Set the type of defense zone 02 2 0n ne en nen nee nn en ne en 16 5 33 4 Set zones dial calling number group 200 202 002 eee 17 5 33 5 Set wired zone alarm model NO alarm NC alarm 17 5 34 Set the time of alarm system 200 0 n een ne enn en ne 17 5 35 Query alarm history list record 2 00 002 17 5 36 Query Arm and Disarm history record 0 0 200 002 002 2022002 17 5 37 SMS commands 2 00 20 een nee en ne en a neen nnn en nnn n eee nneennneennneenns 17 5 37 1 Set phone alarm numbetr 2020202220 en nen ne en cence ence een ce ees 18 5 37 2 Set center number 00 2 000 eee nn nen nee enn eeen ne eenneen aces nes 18 5 37 3 Set helpline number 202 002 200 22 e nen n nen en nce en een e 18 5 37 4 Set SMS alarm numbet 0 00 20000 nne en ee
4. 20 5 37 19 Set CID center account ene en ne eenneeen seen nne 20 5 37 20 Self checking time setting 222 202 2022 022 nen ene nee en nen enn ne ees 20 5 37 21 Set the number of ring tones before picking up 20 5 37 22 Restore the factory setting 2 20 00 00 ne een 2 2 2 2 20 5 37 23 AL I 2 22 22 nn nn nn nnn nn nen en nn nn ne nen nn nen en ence nen een en enn enenen en neneneneenenennenenenen 20 5 37 24 Disari 0 2 22 2202 enn n nee nn nn eee nnn nnn een nnn e ee en nee e e e m 20 5 37 25 Stay ari 2 2222 ne nn enn n enn nen en een en een en eee ee een nee nn enn e een eeen een nee 20 5 37 26 Turn on relay 0 22 002 nnn nen nnn nee en nn nen nee nen n en ene n en neenes 20 5 37 27 Turn off relay 2 002 02nn ence enn en ne nn nen ne en cen ne enc en seen eee neen nee 20 5 37 28 Query the General Parameters 2 02 2 2 200n ene n een ne nee neee 20 5 37 29 Query the number of ring tones and test line 20 5 37 30 Query the phone alarm number 2 02 02 02 eee ecen seen 20 5 37 31 Query the Helpline number 2 0 2022 0n seen ce
5. key hang up system will not dial the next number on list Remark Monitoring time and announcement time is 20s if you want to continue please press 3 or 5 within 20s 5 39 System default zone types are 5 40 System default setting Operation password 1234 SMS message Enable Remote Control Enable Number of ring tones before picking up 8 times Siren sound 1 minute Audible confirmation for remote operation Enable Delay ARM Os Delay alarming Os Cut line detect Off 1 99 zone alarming Siren sound 51 52 wired zones NO 1 99 Zone SMS message content Zone alarm 5 41 Fitting parameters Input voltage DC9V 12V Standby currents lt 25mA Alarm current lt 450mA Wireless frequency 315 433MHz GSM frequency GSM850 900 1800 1900MHz Back up battery Ni MH AAA 6 DC7 24V Alarm loudness 110dB 22 Detailed parameters The alarm should be compatible with PT2262 PT2240 and EV1527 Using PT2262 encoding the resistance is recommended 1 5M 4 7M using with EV1527 encoding the resistance is recommended 150K 470K Alarm loudness 110dB Detailed accessories parameters The alarm should be compatible with PT2262 PT2240 and EV1527 Using PT2262 encoding the resistance is recommended 1 5M 4 7M using with EV1527 encoding the resistance by 150K 470K 6 Guideline for Installing Door or Window Sensor J A B The sur
6. insert the power adapter output of electricity host power supply hole at this point the host voice prompt welcome to use intelligent voice alarm the backup battery switch to ON 5 2 ARM The system is at a fully ready status where all detectors are activated in a working state when the some events burglar fire gas leak etc happened and detected alarm system alarm right away In ARM status the host will display ARM To activate by remote control press ARM key once To activate by keyboard on panel keyboard DISARM keys once 5 3 DISARM All sensors are deactivated and will not be respond to any events expect the detector in Emergency zones and the Panic button in the remote control In a DISARM status the host will display DISARM To activate by remote control press DISARM key once To activate by keyboard press DISARM keys once 5 4 STAY ALARM This is for partial arming of the alarm system when there are people at home only some of the selected sensors are activated and could be triggered by events In a STAY ARM status the host will display STAY ALARM To activate by remote control press STAY ALARM key once To activate by keyboard press STAY ALARM key once 10 5 5 Emergency alarm When an emergency occurs press emergency button on the remote control or on panel to activate alarm Remark If password protect function is open you need to enter password before
7. 13 5 37 30 Query the phone alarm number Syntax 1234 30 group NO 01 06 5 37 31 Query the Helpline number Syntax 1234 30 group NO07 09 5 37 32 Query SMS number Syntax 1234 40 group NO01 06 5 37 33 Query alarm center number Syntax 1234 40 group NO 07 08 5 37 34 Query the system date and time Syntax 1234 56 5 37 35 Query the scheduled time of arm and disarm Syntax 1234 57 group NO 01 04 21 5 37 36 Query the defense zone type Syntax 1234 60 zone number 01 99 5 37 37 Query the alarm mode of the wired zone Syntax 1234 61 zone number 51 52 5 37 38 SMS message content setting Syntax 1234 80 zone number 01 99 Content Example set the 60 zone message content as front door open send the message to the alarm panel 12348060front door open 5 37 39 Query the SMS message content of every zone Syntax 1234 81 zone number 01 99 5 38 Remote Control of Panel Remote control operations can be done via any phone You can just dial into the alarm panel and user will be asked for password upon connected and alarm will automatically hang up call if password is incorrect original password 1234 1 key arming 2 key disarming 3 key monitoring open 4 key monitoring closed 5 key turn on announcement 6 key turn off announcement 7 key siren ringing 8 key stop siren sound
8. OFF 2002 220 een nee neen 14 5 21 Set alarm Output ON OFF 22 22 en nee n nen ne en nen ne en cnn e eens een nee 14 5 22 Set remote control accompanying sound 15 5 23 Scheduled arm and disarm time setting 15 5 24 Set CID numbetr 2 2 0 00 00 een nn en a nnen ne nnen nn eeenneeennneenneeenne 15 5 25 Set the Hand shake Tone 15 5 26 Set the mode of uploading arm disarm message 0 15 5 27 Set scheduled self checking Test Time 220 002 0000 2 0e20e2200 15 5 28 Set scheduled self checking Test Week 2 0 20eneeeecenneene 15 5 29 Set the LCD save ON OFF 202 220 0 0e nese nen neces nn 7 272 nen en ence ne nencenens 15 5 30 Set Tamper ON OFF 2 20 2222 e enn nn nen ne enn en ne en nen ne e 15 5 31 Restore factory setting 0 20 20 0n nee n ne en nnn en nee nn en nce nn enn e een ee nee 16 5 32 Total System Reset 00 0 enn n nn en nen nn ence enn en nee n enn nen nen neen eee ns 16 5 33 Set the type of defense zone
9. een 18 5 37 5 Set the password 2 2 0 2 0 nnn en nen ne en nnn nnn nen een ne enn en ne en cen nees 18 5 37 6 Set delay arm time 202 200 000 0e nee en nen ne enn nn en nee ne en nee nenneeees 18 5 37 7 Set delay alarm time 2 00 22 000 en cnn nn en nen een ne enn en ne en nen nees 18 5 37 8 Set length of Siren sound 2 00 0020 e enn en en ne een en seen een nee nee 18 5 37 9 Set the date and time 18 5 37 10 Scheduled arm and disarm time setting 18 5 37 11 Set the type of defense zone 202 2222 n en ne enn en ene ne en nen eens 19 5 37 12 Set mode of wired alarm Zone 19 5 37 13 Zone setting 2022 n enn e en nnn en nee ee eee ee nee en nee ence ne en een nees 19 5 37 14 Volume control of the voice prompt 0 02 00 022000 19 5 37 16 Power saving mode setting 0 220 22 en ne en nen ne enn en ne en nee nees 19 5 37 17 Volume adjustment of Internal siren 00 00 022000 19 5 37 18 Set the mode of uploading arm disarm message
10. n cence ence nn en nee en en ne een ee nee 10 5 6 Phone number settings 2 0 2020 en nee nn en ne en nen n een n en ne en een ne 10 5 6 1 Set up voice alarm phone number 0 0 02 0 002 00 11 5 6 2 Delete voice alarm phone numbet 0 00 2 5 11 5 6 3 Set up Contact ID phone numbetr 22 2 5 11 5 6 4 Delete Contact ID phone number 02 11 5 6 5 Set up for help alarm phone number 11 5 6 6 Delete for help alarm phone number 11 5 6 7 Set phone number to receive SMS message 0 11 5 6 8 Delete SMS phone number 0 2 0n ne en nen ene nen nee nes 12 5 6 9 Voice Call 202 220 0n nnn enn n en nnn ee nnn e ence een eeen nee ennneen anne snes 12 5 7 Pre record Voice Message 0 2 22 00 n ne nnnn nn en nnn ne en nce nee en nen nenneeees 12 5 8 Add AccessorieS 00 2 00 0002 nn neennneen nen en nen en anne nn nen scene en eeenneeenne 12 5 8 1 Add Remote Control 12 5 8 2 Delete the remote control
11. other operations the initial password is 1234 Disarming Arming Stay Arming Emergency 5 6 Phone Number Settings The model can support 6 groups of alarm numbers 2 groups CID numbers 3 groups help numbers 6 groups SMS numbers Each phone number shouldn t exceed 31 digits As follow Number Settings Number Settings fy 1 Alarm numbers 16 30 ry VJ 2 CID numbers 3 Help mmbers 13 11 08 Fri o 4 SMS z A Arming Voice calls OK Enter ESC Retum OK Enter ESC Retum Press Menu Press 1 Picture 5 1 5 6 1 Set up voice alarm phone number As picture 5 1 Press menu to enter main menu Press Up Down move the cursor to 1 Alarm numbers press OK or number 1 to enter Alarm number settings choose group number 1 6 then input alarm number like 13812345678 Press OK to save press ESC can back to the menu Remark For users who use the telephone line extension you should dial a number such as 9 to pick 663499 up a dialing tone press Arming to add a then input the alarm number 5 6 2 Delete voice alarm phone number As picture 5 1 enter Alarm number press menu button to delete the number than press OK to save the settings Press ESC can back to the menu 11 5 6 3 Set up Contact ID phone number As picture 5 1 Press menu to enter main menu Press Up Down Jmove the cursor tof 2 CID numbers press LOK or number 2 to enter CID number settings choose group numbe
12. 0 13 11 08 FRI GOW W 1 4 7 G E The front figure of the host 7 NUMBER ARM UP l DISARM DOWN a 2 5 3 O 2 MENU DELETE The touch key figure of the host ooo O PHONE LINE SIREN POWER a VZ POWER SIREN acs SWITCH bL AC 220V I WIRED DOOR SENSORS the connection method of wired door sensor and PIR sensor m Notice Display DISARM Alarm host in DISARM status Display ARM Alarm host in ARM status Display STAY ARM Alarm host in STAY ARM status TFT Display XX zone XX zone ina ARM status display arming 1 Display 98 zone arming Emergency arming by pressing the emergency button cy Display 97 zone arming The host was defused or moved SIM Card light SIM Card loaded correctly 4 Alarm Process 4 1 Alarm process description 1 The host is in ARM status 2 When the detectors was triggered the alarm will send to host by wired or wireless 3 The host will alert 4 The host upload the alarm to the CID center 5 The host call SMS to the user 6 Tthe user can remote control the host after picked up the phone After Panel alerts it will automatically dial the preset telephone number for three times until connected When the user picks up the phone a piece of pre recorded voice message will be played back immediately and let the receiver noted about the even
13. 9876 as the password __ send message to the alarm panel 1234509876 5 37 6 Set delay arm time Syntax 1234 51 0 99 seconds Example to set the delay arm time for 30s send message to the alarm panel 12345130 5 37 7 Set delay alarm time Syntax 1234 4 group number 7 8 phone number Example to set 13812345678 as the first group center number send message to the alarm panel 12344713812345678 5 37 8 Set length of Siren sound Syntax 1234 53 0 20 minutes Example you want to make a siren sound 5 Minutes send message to the alarm panel 12345305 Note if you set it as 0 means siren without sound when alarming 5 37 9 Set the date and time Syntax 1234 56 4 digits year 1 12 month 1 31day 0 23hours 0 59minutes 0 59 seconds Example now is 8 Oct 2013 4 38 18 pm send message to the alarm panel 12345620131008163818 19 5 37 10 Scheduled arm and disarm time setting Syntax 12344 57 Group NO 01 04 AAAA Scheduled time of arm BBBB Scheduled time of disarm week number Example set up the second group scheduled time to arm at12 00am and disarm at 18 00 means 06 00pm this is valid for Monday Tuesday Wednesday Thursday and Friday of each week send message to the alarm panel 123457021200180012345 5 37 11 Set the type of defense zone Syntax 1234 60 00 99 zone number 1 8Type 01 Toset 99 zone type 00 99 represents 0 99 zone number 1 8 represents one of the 8 zone type 1 NORMAL 2 STA
14. SC Return Press Menu Press 2 Picture 5 3 5 8 1 Add remote control As picture 5 3 Press menu to enter main menu Press 2 to enter Add accessories Press 1 to enter add remote control the menu would be indicate that type the Number 00 99 if add 1 remote control please input 01 add 22th remote control please input 22 then press OK to save the settings Then press any key of the remote control to send a signal to the alarm panel voice prompt Set successful and LCD display has been saved means add successful If beep only once means this remote control has been configured before and cannot be added again If want to add more remote control can press any key of other remote control Alarm panel can configure up to 150 remote control of different coding 5 8 2 Delete the remote control As picture 5 3 press 3 to enter Del remote control then display type the Number 00 99 If delete Ist remote control please input 01 delete 22th remote control then input 22 press Input Arming 66399 as to delete all remote controls Later press OK to delete certain zones remote control or all remote controls 13 5 8 3 Add detector As picture 5 3 press 2 to enter add detector the menu would be indicate that type the Number 00 99 if add 1st detector please input 01 add 89 input 89 Press OK to save the settings Then press any key of the detector to send a signal to the alarm panel Panel
15. Touch Keypad TFT Color Display GSM amp PSTN Burglar Alarm System KR 8218G User Guider Table of the content Identification Section 0 0 000 een nee en nee ennneennnee nn eeennneen 4 1 SummMariZe 2 22 2222 ne nn nnn een en nn nn nn ene ne eee eee eee eee eee eenees 6 2 System Features 00 22een nen ne enn en ne en nen eee n en nn ence nen nee nenneennens 6 3 Alarm system Setup 0 0 e een ne enn en ene nn en nce nn een nn ene een ee nee en een neenes 6 4 Alarm ProceSS 0 en ee 8 4 1 Alarm process description 2 00 02 2000 0ee nen n ne ec een ee 8 4 2 Alarm SCHEMATICS nennenenenen neem en ne ne nenee ne nen nen nenennenes 9 5 Alarm System Operation and settings 00 0 000n cee neenneen een nee 9 5 1 Alarm Panel Initial Setup 0 00 202 neeen een 9 5 2 Ar Mann nnn nnn nn nnn nn nn nen ne nee ee ee re en eee ee eee nee ee eee nen eee eee e ee eeeeeees 9 5 3 Stay Arin 0 20 22 en seen een en nen n nee ence seen ene nee en nnn enn n en neen eee neen eee 10 5 4 Disarm 2 222 ne nen en en nnn nn enn en ene eee ee eee eee eee eee en eens 10 5 5 Emergency alarm 2 22 2200 02 een nen
16. Y ARM 3 INTELLIGENT 4 EMERGENCY 5 CLOSED 6 CHIME 7 WELCOME 8 HELP SENIOR The last 0 1 represents 0 siren of panel produce no sound upon alarming while 1 is sounded send message to the alarm panel 1234601880 Example Set zone number 18 as help senior zone type and siren not sound upon alarming 5 37 12 Set mode of wired alarm zone Syntax 1234 61 zone NO 51 52 0 1 here 0 means NO and 1 means NC NO means short circuit to alarm NC means open circuit to alarm Example set the 51th zone as NO alarm send message to the alarm panel 123461511 5 37 13 Zone setting Syntax 1234 64 zone NO 01 99 CID feature codes AAA AAA means CID feature codes 100 is medical aid 110 is fire alarm 121 is robbery alarm 122 is mute robbery alarm 130 is burglary alarm 131 is peripheral burglary alarm 151 is gas alarm Example set 38 zone is gas alarm send message to the alarm panel 12346438151 5 37 14 Volume control of the voice prompt Syntax 1234 79 volume level 1 7 Example set the voice volume to be level 3 send message to the alarm panel 1234793 5 37 15 Hand shake Tone setting Syntax 1234 83 precision level 0 9 Example set it to be 4 send the message to the alarm panel 1234834 5 37 16 Power saving mode setting Syntax 1234 84 1 0 Example set LCD keeps on send the message to the alarm panel 1234840 5 37 17 Volume adjustment of Internal siren Syntax 1234 87 v
17. beep twice voice prompt Set successful and LCD display has been saved means successful If beep only once means this detector has been configured before and cannot be added again If want to add more detector can press any key of other detector Alarm panel can configure up to 150 detectors of different coding 5 8 4 Delete detector As picture 5 3 press 4 to enter Delete detector then display type the Number 00 99 if delete 1st 663499 detector please input 01 delete 89 input 89 press Input Arming Jas to delete all detectors Then press OK to delete certain zones detector or all detectors 5 9 Set delay for system arm System Settings System Settings Ss 1 Delay Settings 1 6 30 rt i 2 Password Settings 3 3 Voice Settings 13 11 08 Fri 4 Siren Settings 5 Phone amp SMS Setting OK Enter ESC Retum OK Enter ESC Return Arming Press Menu Press 3 Picture 5 4 As picture 5 4 choose 1 Delay settings input the delay time from 0 to 99 seconds after Arming delay 0 means arming without delay 5 10 Set the time of delay for alarming As picture 5 4 press 1 Delay Setting press the OK to move cursor behind Alarm Delay then input the delay the number of seconds 0 99 seconds 0 means no delay 5 11 Set the alarm system password As picture 5 4 press 2 Password Setting input four new password behind Password the original password is 1234 5 12 Set keyboard pa
18. ccept the cable remote set functions 20 means the host is on the phone after received 20 times rings in continuous 5 19 Set the anti tampering of telephone cord ON OFF As picture 5 4 press 5 Phon amp SMS setting press Down button move the cursor to Test line press Menu switch ON or OFF 5 20 Set the SMS Messaging reply ON OFF As picture 5 4 press 5 Phon amp SMS setting press Down move the cursor to SMS reply press Menu switch ON or OFF On is means user sent the setting message to the alarm system host the host will reply the setting is correctly 5 21 Set alarm Output ON OFF As picture 5 4 press 5 5 Phon amp SMS setting press Down move the cursor to Alarm Out press Menu switch ON or OFF On is means when the system is alarm relay will short circuit output at the same time COM and CO short circuit output 15 5 22 Set remote control accompanying sound System Setting System Setting A 1 Delay Setting E i i 2 Password setting 16 30 i 3 Voice Setting 13 11 08 Fi I 4 4 Siren Setting Disarming 5 PhoneSMS Setting OK Enter ESC Return OK Enter ESC Return Press Menu button Press 3 button Picture 5 5 As picture 5 5 press 6 sound setting The menu prompts Enter number 00 99 then press OK press Menu switch ON or OFF On is means press the remote control in these number the siren will sound di di 5 23 Scheduled arm and disarm time setting As picture 5 5 press 7 Timing Setting The
19. e 5 5 press 0 Restore Factory press 1 then press OK alarm system prompt Restore Factory This feature will restore all settings to factory default apart from the configuration of sensors and remote control 5 32 Total System Reset As picture 5 5 press 0 Restore Factory then press 2 long press OK till the the completion of the host to restart All configuration has been cleared all sensors and remote controlled are deleted technique table as 5 40 5 33 Set the type of defense zone Type of defense zone setting is include CID feature codes Siren On Off when arming defense zones types call number group when arming wired zones NO alarm or NC alarm Setting method is as follows Zone Setting Zone Setting gt a Enter Number 00 99 16 30 ned 13 11 08 Fii ian Disarming OK Enter ESC Return OK Enter ESC Return Press Menu button Press 5 button Picture 5 6 5 33 1 Setting CID event codes As picture 5 6 input defense zone 1 99 behind Enter Number press OK then input the event coding behind CID event codes 100 is medical aid 110 is fire alarm 121 is robbery alarm 122 is mute robbery alarm 130 is burglary alarm 131 is peripheral burglary alarm 151 is gas alarm 5 33 2 Set siren ON OFF when Arming As picture 5 6 input defense zone 1 99 behind Enter Number press OK move the cursor behind Siren press Menu switch ON OFF Off is means the detector in these zone arming the alarm system not siren Th
20. e of zone is for elderly safety no matter in what status the panel will alarm once sensor with this zone type is triggered System automatically dial 3groups help senior number once the phone picked up it remind with voice of someone need help Specific number to certain zone Set voice alarm phone number for specific defense zone help senior defense zone dial 3 groups number System Time Alarm panel system time Alarm Record Alarm message recorded by control panel including defense zone and alarm time Can display 102 groups call logs Arm disarm Record Time and mode of every arm disarm recorded by the host Can display recent 72 groups records 1 Summarize 1 7 inch TFT color display touch screen keypad built in high performance CPU this high end dual network GSM PSTN alarm system has reliable performance and favorable operability It connects with wireless infrared detector door sensor smoke detector gas detector emergency button and other accessories When the detector is trigger the alarm system will notify the user by 120 decibels alarm sound and at the same time a call and SMS message will be sent to the user It is a choice of stability reliability security and user friendliness security product Features are very practical cost effective completed configuration and ease of use It has been widely used in homes factories schools shops convenience stores financial and banking workplace community center and res
21. einforce bracket with screws Find the base and reinforce it with two screws in the wall Press the PIR with bracket into the center hole of base and then adjust the best angle of detecting This method is suitable for engineering installation Attention 1 Within coverage of detection there should be no any objects for obstruction 2 There should be no two infrared detectors in the same as they will possibly intervene with each other 3 Avoid the detector facing window cooling or warming machines or other appliances that cause the temperature changing sharply and thus cause false alarm 4 Most infra red detector needs about 5 minutes to heat up before READY for normal operation 5 Regular PIR motion sensor is for indoor use unless the specification stated otherwise Avoid to face to air conditioner 6 When intruder is detected PIR will need few seconds to confirm then transmitter the alarm signal to avoid fault alarm and missed alarm 7 Unless specifies otherwise most infra red detector are indoor use and not reliable to use outdoor 8 Troubleshooting 24 Troubleshooting Reasons Methods 1 No dial for alarm 1 no arming 2 alerting phone unsetted 3 parts improperly installed distance too far away 4 code no match 1 do arming operation 2 re set according to the specification 3 coordinating the location of parts 4 re coding 2 Can t operate long distance password input wron
22. en press OK to save 5 33 3 Set the type of defense zone As picture 5 6 Input defense zone 1 99 behind Enter Number press OK then press down move the cursor behind the Types Press Menu switch 8 kinds type of defense zone 1 normal zones 2 stay arm zone 3 Intelligent zone 4 Emergency zone 5 Closed zone 6 Chime zone 7 welcome zone 8 Help senior zone Press OK to save 17 5 33 4 Set zones dial calling number group As picture 5 6 input zones number 1 99 behind Enter Number press OK then press down move the cursor behind Zone dial input the calling number group when this zones alarm can be used 123456 group but if the zone type is help zones the group fixed for the help group press OK to Save 5 33 5 Set wired zone alarm model NO alarm NC alarm As picture 5 6 Input the wired zones 51 52 behind Enter Number press OK then press down move the cursor behind Wired model press Menu switch the NO alarm NC alarm press OK to save 5 34 Set the time of alarm system Clock Setting Clock Setting i A 13 11 08 16 30 18 16 30 K 13 11 08 Fii ir Disarming OK Enter ESC Return OK Enter ESC Return Press Menu button Press 6 button Picture 5 7 As Picture 5 7 input the date and time as picture press OK to save 5 35 Query alarm history list record History List History List ft 1 Alarim list 16 30 Cry iJ 2 Alarmidisarm list 13 11 08 Fi D Disarming OK Enter ESC Return OK Enter ESC Retu
23. face for door sensor installation should be clean so door sensor can be attached to the door and frame firmly with double faced adhesive 1 Each kit door sensor include sensor A as in diagram and magnet B as in diagram B must be the right hand side A and B one on fixed door frame another one on movable door 2 A and B must be aline The distance between A and B not exceeding 1 cm 3 Upon installed door sensor should be tested by open the door and check if the indicator on door sensor flashes for 1 second 4 The indicator light lit for one second means alarm In case the door sensor is running out of battery the indicator should be kept lit as a low voltage notification 5 A B can also be reinforced with screws A bottom out then screw in the bottom buckle the cover to the bottom B can be directly fixed on the screw back 23 7 Guideline for Installing PIR Motion Sensor Before use make sure the power switch of PIR motion sensors is at the ON position Installation height is about 2 2 meters above ground and the optimized detection angle for most motion sensor is 90 degree The sensor should face the detected area with this consideration for best coverage It is advised to install with the face of motion sensor perpendicular to the most probable moving detection of people for the highest effective detection Installation Remove the supplied mounting bracket the bracket is alined to the detector Bottom screw holes r
24. g When detector triggered the host delay a period of time to alarm Long distance Control Call host number by telephone or phone can control the control panel when host number picking up System Password System default password 1234 System Volume Volume of voice prompt while operating the host System Voice Voice prompt on off while operating the host Siren beep time Time for siren alarm unit is minute Number of ring tones Number of ring tones before picking up when setting the host by telephone or Phone Offline Detection Alarm ON OFF when detecting telephone line fault SMS Reply Enable or disable SMS reply when user set the host via SMS message Alarm output Relay output On Off when alarm Remote Control Audio Arm Disarm by remote control voice prompt the operation at the same time enable or disable the siren Scheduled Arm Disarm Set a period of time for arm disarm host automatically change the status of arm disarm User Code Code of the host in CID center consist of 4 numbers Centre Accuracy Requirement for accurate signal when change information between host and CID Center Arm Disarm Upload When status of arm disarm change upload the information to CID or not Self Test Time will regular upload the info to CID for smooth connection Self Test week will regular upload the info to CID for smooth connection Power saving back light auto close the back light if no operation Tamper Switch the panel has a tamper s
25. gly password input or changed to new password Or forced always clear factory set back 3 no ISD recorded voice prompt when alerting ISD Voice prompt un recorded Record it again according to user manual 4 remote controller no work 1 coding unmatched with the host 2 insufficient power 3 battery pieces poor contact or corroded 4 unmatched with host 1 re coding 2 change battery in the same type 3 eliminating the dirt on the pieces caused by corrosion 4 contact the local dealer to change the matched remote controller 5 infrared detector no work low power change to the same type battery 6 Infrared Beams not work 1 not power on 2 Electrically shorted 3 Beam tube dislocation Power on Reconnect wire Adjust beams 7 siren no sound 1 siren plug or jack in short circuit or broken line 2 plug line in short circuit 3 siren closed 1 repair or change plug or jack 2 change the jack line 3 set siren ringing time on the host 8 The transmitter distance for host is shortened l a nearby emitter is sending code 2 host receiver stoppage 3 standby battery of the host insufficient 1 find the interfering source and eliminate it 2 post back to the factory for amendment 3 check host power whether plugged well 9 Consistently alarm once power open Telephone lines not connected and telephone function Lines anti tampe
26. idential area to provide protection to valuable assets 2 System Feature E TFT color display humanized menu voice prompt and easy to use H Up to 99 wireless zones each wireless zones can be defined as one of the 8 zone types each zone can setup the siren independently E Four sets of scheduled arm disarmed function each timed arm disarm you can select the period of time and different defense zone E 6 groups preset telephone number for alert calling not lost number without power E Support ISD automatic voice mailbox for playback message upon alert Maximum length of voice message is 10 seconds E Remote control for arming disarming monitoring and speaking setting up for relay and siren W Wireless intelligent study coding compatible with PT2262 normal encoding and 1527 encoding Maximum support 150 remote control and 150 sensors W Integrated clock chip time will not lose without power M Unique black box feature display most recent 72 disarmed records and 102 recent alarm recording with accurate alarm time and zones E Compatible with the international alarm networking protocol CONTACT ID 3 Alarm System Setup Alarm panel should be installed at a central location with best transmission to all the wireless sensors and accessories Keep the panel away from large metal objects or household appliances with high frequency interference and avoid barriers such as concrete walls with metal frame inside and fire doors 16 3
27. menu prompts Enter Number 1 4 then press OK input the Arming Time Disarm time Week press Menu switch On or OFF 5 24 Set CID number As picture 5 5 press 8 CID setting input four number CID coding behind User Coding then press OK to save 5 25 Set the Hand shake Tone As picture 5 5 press 8 CID setting then OK Input the 0 9 to behind Hand shake Tone Press OK to save 5 26 Set the mode of uploading arm disarm message As picture 5 5 press 8 CID setting then OK move the cursor behind Arm amp Disarm then press Menu switch No sent Arm Disarm AI press OK to save 5 27 Set scheduled self checking Test Time As picture 5 5 Press 8 CID setting then press OK move the cursor behind Test Time input the self check test time then press OK to save 5 28 Set scheduled self checking Test Week As picture 5 5 Press 8 CID setting then press OK move the cursor behind Test Week input the self check test week 1234567 then press OK to save 5 29 Set the LCD save ON OFF As picture 5 5 press 9 LCD Save amp Tamper move cursor behind Lcd Save press Menu switch ON or OFF Press OK to save 16 5 30 Set Tamper ON OFF As picture 5 5 press 9 LCD Save amp Tamper press OK move the cursor behind Tamper press Menu switch ON or OFF OFF is means the host not alarm when the tamper is trigger Press OK to Save 5 31 Restore factory setting AS pictur
28. n neen nee neee 20 5 37 32 Query SMS number 2022 2020 0n nnn nn enn ne nen nee n en nee nc enn e ence eens 20 5 37 33 Query alarm center number 200 202 002 nee nn en ne en cen nen cans 20 5 37 34 Query the system date and tiMe ens 20 5 37 35 Query the scheduled time of arm and disarm 20 5 37 36 Query the defense zone type 22 2 0n ne en ne nnn en nen ne 21 5 37 37 Query the alarm mode of the wired zone 0 0 00 21 5 37 37 Query the alarm mode of the wired Zone 21 5 37 39 Query the SMS message content of every zone 21 5 38 Remote Control of Panel 21 5 39 System default zone types 2 0 2022 20 enn n nen n ne nn en nce en een ne ene e 21 5 40 System default setting 2 02 20 0n 2 seen nn nnn en ee ne en nen nce nn enn e eens 21 5 41 Fitting parameters 0 2 0 2022 n enn ne nn en nce nn enn ce ene e 21 6 Guideline for Installing Door or Window Sensor 00 0 00 00 0 22 7 Guideline for Installing PIR Motion Sensor
29. olume level 0 7 Example set it as 3 send the message to the alarm panel 1234873 Note set it as O means internal siren would be not sound when alarming 20 5 37 18 Set the mode of uploading arm disarm message Syntax 1234 91 0 3 Example Only upload the arm message send the message to the alarm panel 1234911 Here 0 means Don t upload any message 1 Upload the arm message 2 Upload the disarm message 3 Upload the message of ARM DISARM 5 37 19 Set CID center account Syntax 1234 92 AAAA 0 9 Example set the CID center account as 9988 send the message to the alarm panel 1234929988 5 37 20 Self checking time setting Syntax 1234 94 Self checking time AAAA week number Example set every Sunday 01 00 am the alarm system with the alarm center to self check send the message to the alarm panel 12349401007 5 37 21 Set the number of ring tones before picking up Syntax 1234 18 0 20 Example set it to 6 send the message to the alarm panel 12341806 5 37 22 Restore the factory setting Syntax 1234 9898 5 37 23 Arm Syntax 1234 1 5 37 24 Disarm Syntax 1234 0 5 37 25 Stay arm Syntax 1234 2 5 37 26 Turn on relay Syntax 1234 3 5 37 27 Turn off relay Syntax 1234 4 5 37 28 Query the General Parameters Syntax 1234 11 5 37 29 Query the number of ring tones and test line Syntax 1234
30. press ESC back to the menu Remark For users who use the telephone line extension you should dial a number such as 9 to pick 663499 up a dialing tone press Arming to add a then input the alarm number 5 6 8 Delete SMS phone number As picture 5 1 enter SMS number press menu J button to delete the number than press OK to save the settings Press ESC back to the menu 5 6 9 Voice call As picture 5 1 Press menu to enter main menu Press Up Down move the cursor to 5 Voice calls press LOK or number 5 to enter then input number like 13812345678 Press OK to dial press ESC hang up the call 12 5 7 Pre record Voice Message Alarm panel will play a pre recorded voice message in the alarm call As follow Message Record Message Record Fy Press 1 to start Recordmg 16 30 LA 13 11 08 Fri Arming OK Enter ESC Return Press Menu Press 4 Picture 5 2 As picture 5 2 press menu to enter main menu Press 4 to enter message recording and then press 1 to start recording speak your message to the panel for recording System will record 10 seconds and then automatically exit Massage should be simple like This is whose house be intruded please help 5 8 Add Accessories Add Accessories Add Accessories 1 Add Remote Control mi a 16 30 2 Add Detecotr 13 11 08 Fri p 3 Del Remote Control ii 4 Delete Detector Arming OK Enter ESC Retum OK Enter E
31. r activated connect telephone line or close anti tamper line function 25
32. r 1 2 then input CID number like 88889999 Press OK to save press ESC back to the menu Remark For users who use the telephone line extension you should dial a number such as 9 to pick 663499 up a dialing tone press Arming to add a then input the alarm number 5 6 4 Delete Contact ID phone number As picture 5 1 enter CID number press menu button to delete the number than press OK to save the settings Press ESC back to the menu 5 6 5 Set up for help alarm phone number As picture 5 1 Press menu to enter main menu Press Up Down move the cursor tof 3 CID numbers press OK or number 3 to enter help number settings choose group number 1 3 then input help number like 13812345678 Press OK to save press ESC back to the menu Remark For users who use the telephone line extension you should dial a number such as 9 to pick 663499 up a dialing tone press Arming to add a then input the alarm number 5 6 6 Delete for help alarm phone number As picture 5 1 enter Help number press menu button to delete the number than press OK to save the settings Press ESC back to the menu 5 6 7 Set phone number to receive SMS message As picture 5 1 Press menu to enter main menu Press Up Down move the cursor to 4 SMS numbers press OK or number 4 to enter SMS number settings choose group number 1 6 then input SMS number like 13812345678 Press LOK to save
33. rn Press Menu button Press 7 button Picture 5 8 As picture 5 8 press OK to History list press Up Down query the alarm history The maximum 102 history record 5 36 Query Arm and Disarm history record As picture 5 8 press Down move the cursor behind 2 Arm amp Disarm List press OK enter the query arm and disarm history record press Up Down query the arm and disarm record The maximum 72 history record 18 5 37 SMS commands You can set the alarm panel to the menu also can use SMS message to set it The following instructions are only for SMS command to control panel remotely 5 37 1 Set phone alarm number Syntax 1234 3 group number 1 6 phone number Example to set 13812345678 as the first group phone alarm number send message to the alarm panel 12343113812345678 5 37 2 Set center number Syntax 1234 4 group number 7 8 phone number Example to set 13812345678 as the first group center number send message to the alarm panel 12344713812345678 5 37 3 Set helpline number Syntax 1234 3 group number 7 9 phone number Example to set 13812345678 as the first group helpline number send message to the alarm panel 12343713812345678 5 37 4 Set SMS alarm number Syntax 1234 4 group number 1 6 phone number Example to set 13812345678 as the first group SMS alarm number send message to the alarm panel 12344113812345678 5 37 5 Set the password Syntax 1234 50 4digits password Example to set
34. ssword protection feature As picture 5 4 press 2 Password Setting then press OK to move cursor behind Keypad Lock Press the Menu switch ON or OFF 5 13 System voice volume adjustment As picture 5 4 press 3 Voice Setting press OK to move cursor behind System volume then input the volume level 1 7 1 is minimum volume 7 is maximum volume Press OK to save 14 5 14 Set system voice ON or OFF As picture 5 4 press 3 Voice Setting then press Down move the cursor behind System voice press Menu switch switch ON or OFF OFF means the alarm system no voice in the operation but with the press sound 5 15 Set the external alarm volume As picture 5 4 press 4 Siren Setting press OK button move the cursor to External volume input the volume level 00 99 00 means mute 99 the maximum sound press OK to save 5 16 set the internal alarm volume As picture 5 4 press 4 Siren Setting press Down Jbutton move the cursor to Built in volume then input the volume level 00 99 00 means mute 99 the maximum sound 5 17 Set length of Siren sound As picture 5 4 press 4 Siren Setting press Down button move the cursor to Siren on time input 0 20 minutes 0 is means no siren sound after alarm 5 18 Set number of ring tones for remote As picture 5 4 press 5 Phon amp SMS setting press OK button move the cursor behind Ring time then input the number of ring tones 1 20 0 indicates the host don t a
35. t Upon receiving the call it can also control the alarm panel remotely via the phone according to the command below User will not be asked for password upon connected and alarm will automatically hang up call within receiving any instruction within 20 seconds 1 key arming 2 key disarming 3 key monitoring open 4 key monitoring closed 5 key turn on announcement 6 key turn off announcement 7 key siren ringing 8 key stop siren sound 9 key turn on relay 0 key turn off relay key hang up system will not dial the next number on list Remark If not hang up using key or disarm using 2 key the system will retry to call the next phone numbers on list until one connected Note the monitoring and announcement time is 20 seconds please press 3 or 5 key to continue if you need infrared 4 2 ALARM SCHEMATICS fence panic siren alarming button phone or cellphone Call SMS to the user door detectors sensor call to CID PIR sensor CID center gas detector 5 Alarm System Operation and settings 5 1 Alarm Panel Initial Setup At first Connect the telephone line to the perimeter phone interface of the host and connect telephone to the inside phone interface Secondly connect the siren to the siren interface and plug in adapter At last the host will voice prompt welcome to use alarm system then it s done after switch the power switch to ON
36. with will alarm if moved it Record Support ISD automatic voice mailbox for playback message upon alert Network code defined the alarm attributes such as burglar alarm fire alarm by three digit numbers Build in siren can setup to ring the siren or not when alerting Defense Zone Type 8 types Defence zone optional NORMAL Defense Zone The Panel only works on the arming status When disarming there is no response STAY Defense zone Can be shut off solely through the remote control keyboard to avoid the Infrared Detectors and other in room detectors from misinformation when master is resting at home INTELLIGENT Defense zone If the detector in the Defense zone is triggered only once it will not immediately alarm But if being triggered once again within 30 seconds after the first triggering it will alarm immediately EMERGENCY Defense zone No matter on arming or disarming status if detector is triggered it will alert Usually used in connecting with Smoke Detectors Gas Detectors and emergency button etc CLOSED Defense zone No matter arming or disarming status detectors will not alert even being triggered CHIME Zone No matter in what status when sensor with this zone is triggered a welcome door bell will be ring as notification WELCOME Zone Working on the disarming status when sensor with this zone is triggered a welcome voice message will be played While in arming status system alarms HELP SENIOR Defense Zone This typ

Download Pdf Manuals

image

Related Search

Related Contents

manuels d`utilisation pour ce produit    Sony DAV-HDX686W Home Theater System User Manual  iSimple ISTY11 Satellite Radio User Manual  Adaptador MINI USB KVM para 2 e 4 PORTAS  Under Counter Lavatory Lavabo Bajo el Mostrador Lavabo Sous  MP-0075, Rev D  Nikon COOLPIX L810  V7 COMPOSITE CABLE 3x CINCH M/M Black 3m  Overview of eScan`s Features  