Home
PT2060-90-User Manual
Contents
1. rms CAUTION The correct frame shell must be grounding with wire otherwise its extremely dangerous if inducted high voltage on 85 132 VAC NEUT LN2 POWER 110V 6A FUSE 47 63 HZ 85 132 VAC HIGH VOLTAGE Figure 6 4 220VAC High Voltage AC power Supply Use the High Voltage AC Power Supply when the rack will be powered by high voltage AC 175 to 264 VAC rms Sg CAUTION tat The correct frame shell must be 8 grounding with wire otherwise N Es extremely dangerous if Res Inducted high voltage Pat e GND 175 264 VAC M eUT LN2 p 1 gt Lu Power 220V 4A FUSE 47 6 HZ 175 264 VAC HIGH VOLTAGE 90 Power Figure 7 ProvibTech Phone 1 713 830 7601 Fax 1 281 754 4972 9 sales provibtech com www provibtech com PT2060 90 POWER Power Supply Module Ground consideration In order to avoid the grounding in loop the system has to supply a single grounding the power supplied a switch and control system ground there The two switches have to be fixed at the same position if mounting two powers The switch default setting is ON to short the COM and the case If the system is grounded at another location you need to be sure the switch is OFF Switch is ON state OFF B ON J When it s here CAUTION Please don t connect power before installing power module Figure 8 Please don t replace fuse or power supply m
2. 85 132VAC PT2060 009004 PT2060 90 Front panel 88 140VDC PT2060 009005 PT2060 90 Back panel 88 140VDC PT2060 009006 PT2060 90 Front panel 20 30VDC PT2060 009007 PT2060 90 Back panel 20 30VDC PT2060 009008 PT2060 90 Fuse 220V 4A 175 264VAC PT2060 009009 PT2060 90 Fuse 110V 6A 85 132VAC 88 140VDC PT2060 009010 PT2060 90 Fuse 24V 16A 20 30VDC PT2060 009011 Front blank Panel PT2060 009012 Back blank Panel ProvibTech Phone 1 713 830 7601 Fax 1 281 754 4972 sales provibtech com www provibtech com 13 PT2060 90 POWER Power Supply Module Examination The encapsulation of PT2060 can protect modules from all kind of damage As soon as the reception user should examine the conducts whether it is damaged and whether it is caused by transportation Please contact the carrier if it happened If no damage is found and the system does not work properly please check the user manual first If the problem can not solve please contact the closer ProvibTech office ProvibTech Phone 1 713 830 7601 Fax 1 281 754 4972 sales provibtech com www provibtech com 14
3. back panel matches the installed front panel 3 Check to see if the fuse on the back panel has blown If the fuse is blown replace it A blown fuse may be due to ProvibTech Phone 1 713 830 7601 Fax 1 281 754 4972 sales provibtech com www provibtech com 11 PT2060 90 POWER Power Supply Module Vv Severe over voltage on the back panel v A fault within the PT2060 Power Supply 4 If steps 1 through 3 do not solve the problem the Power Module may be damaged Please Contact Provibtech Corporation ProvibTech Phone 1 713 830 7601 Fax 1 281 754 4972 sales provibtech com www provibtech com 12 PT2060 90 POWER Power Supply Module Other Information Ordering Information Each PT2060 90 power supply module is consists of two boards front panel and back panel There are four type of front panel and back panel according to different applications So please make your orders using the code listed below PT2060 90 AX BX AX Top half power supply AO None A1 175 264VAC A2 85 132VAC A3 88 140VDC A4 20 30VDC BX Bottom half power supply required for redundancy BO None B1 175 264VAC B2 85 132VAC B3 88 140VDC B4 20 30VDC Accessories There are several accessories for selecting PT2060 009000 PT2060 90 Front panel PT2060 009001 PT2060 90 Back panel 175 264VAC 175 264VAC _ _ on PT2060 009002 PT2060 90 Front panel 85 132VAC PT2060 009003 PT2060 90 Back panel
4. Provib Tech Innovative Machine Monitoring PT2060 Monitor PT2060 90 POWER Power Supply Module User Manual Installation Operation Maintenance PT2060 wj i PT2060 ProvibTech Inc 11011 Brooklet Drive Suite 360 Houston Texas 77099 USA Phone 1 713 830 7601 Fax 1 281 754 4972 Email pvt provibtech com Web www provibtech com PT2060 90 USR A 9 COPY RIGHT PROVIBTECH 2007 PT2060 90 POWER Power Supply Module Contents Receiving Inspection and Handling Guide 3 Ne E 3 Handling and Storing Considerations AA 3 lee TER eler te EE A Eer nioimatioiN saieta a aaa Ea EE 4 Geelen E T E ET 4 Seele A GG lge En CT 5 PIV SICA EE 5 P12060 90 e Le EE 6 Views of the Front Pane liir araarida aei NTE ety A ects Alen eee eee 6 PT2060 90 Field wiring Diagramm 7 ELE 11 WAST CT OM ae oes caressssestes ateeevadanesbesaucd reve seacpsba dance ennananevesWsnere caukbetaneaseeateasavbad sven exist sectebewen dtcaan eases 11 Troubleshooting E 11 Other IMTORMALON a icee2ccenads cendensedeeestas seu ldes cde enaa aaaea eara aaa aaa aaa aaa Aa bananana rinan sanear Rna 13 Ordering Information Auen 13 ACCOSSOMNES EE 13 Ell e RE 14 ProvibTech Phone 1 713 830 7601 Fax 1 281 754 4972 sales provibtech com www provibtech com 2 PT2060 90 POWER Power Supply Module Receiving Inspection and Handling Guide Inspection Check the devices for possible damage that may have occurred from improper transport Dama
5. ges in transit must be recorded on the transport documents All claims for damages must be claimed without delay against the shipper and before the installation Handling and Storing Considerations PT2060 should be handled with care during unpacking and installation Damage to PT2060 is typically caused by rough handling shock or electrostatic discharge ESD Be aware of the following precautions when unpacking and handling PT2060 Rack or any module v Please have attention about the sharp corners sides of the rack to avoid any of injuries during the installation transporting and un installation v All circuit boards and electronic modules associated with this rack contain components which are susceptible to damage caused by electrostatic discharge It should be necessary to discharge any static electricity from yourself and your clothing before handling the rack v Whenever the module is not installed in a system always keep it in the protective antistatic bag ProvibTech Phone 1 713 830 7601 Fax 1 281 754 4972 sales provibtech com www provibtech com 3 PT2060 90 POWER Power Supply Module Module Introduction General Information ProvibTech s PT2060 90 POWER supply module will provide system power to the PT2060 99 system rack and all modules installed in the system rack The power module accepts the following power supply inputs 24VDC 110VDC 110VAC and 220VAC Ga a w If redundancy is required two PT2060 90 po
6. odule and dont disconnect equipment unless power has been switched off or the area is known to be non hazardous ProvibTech Phone 1 713 830 7601 Fax 1 281 754 4972 sales provibtech com www provibtech com 10 PT2060 90 POWER Power Supply Module Maintenance Instruction User should not open the PT2060 90 POWER Power Supply Module and repair the components inside The maintenance here means to check the module working status and determine whether it is in a good condition If it has something abnormal user could change a new one The maintenance period is very important Usually a yearly maintenance is OK If the machine works in an extraordinary environment user should shorten the maintenance interval according to the reality The extraordinary here means v PT2060 is used to monitor critical equipment v PT2060 works in high temperature humid and corrosive environment Troubleshooting This section describes how to troubleshoot a problem with the Power Supply Module AC power connected voltage is present This voltage could cause shock burns or death Power Supply shield may be hot when the rack is operating at high temperatures High voltage may be present on the Power Supplies for several minutes after removal from the rack LED Fault Conditions If the Power Supply OK LED is off check the following items 1 Verify that the correct voltage is connected to the back panel 2 Verify that the installed
7. r details ProvibTech Phone 1 713 830 7601 Fax 1 281 754 4972 sales provibtech com www provibtech com 7 PT2060 90 POWER Power Supply Module 1 24VDC Low Voltage DC Power Supply Use the Low Voltage DC Power Supply when the rack is powered by low voltage DC 20 to 30 VDC 20 30 VDC Power 24V 16A FUSE FUSE 20 30 VDC LOW VOLTAGE 90 POWER _ CAUTION 7 The correct frame shell must be grounding with wire otherwise ___ Es extremely dangerous if inducted high voltage 24VDC 24VDC Old version Figure 4 2 110VDC High Voltage DC Power Supply Use the High Voltage DC Power Supply when the rack will be powered by high voltage DC 88 to 140 VDC wwe 7 och l as GND GND NEUT DC LM D Lia Pover O PoR 110V 6A 110V 6A eo FUSE ff ell FUSE U Jj 88 140 VDC 88 140 VDC HIGH VOLTAGE HIGH VOLTAGE z 0 Power 90 Power TN r VII UL 1 CAUTION The correct frame shell must be grounding with wire otherwise Its extremely dangerous if inducted high voltage 110VDC 110VDC ProvibTech Phone 1 713 830 7601 Fax 1 281 754 4972 8 sales provibtech com www provibtech com PT2060 90 POWER Power Supply Module 3 110VAC Low Voltage AC power Supply Use the Low Voltage AC Power Supply when the rack will be powered by low voltage AC 85 to 132 VAC
8. these modules is the first slot on the right side of the system rack with one module installed on the top and the other installed on the bottom of the slot Weight 1 0 kg 2 0 Ibs ProvibTech Phone 1 713 830 7601 Fax 1 281 754 4972 sales provibtech com www provibtech com 5 PT2060 90 POWER Power Supply Module PT2060 90 Operation Views of the Front Panel PT2060 90 Power lt 1 PT2060 ot ProvibTech com Figure 2 OK LED On when the PT2060 90 module works well v Fixing Screw It is used to fix the front panel of the PT2060 90 De energize before mounting the power supply ProvibTech Phone 1 713 830 7601 Fax 1 281 754 4972 sales provibtech com www provibtech com 6 PT2060 90 POWER Power Supply Module PT2060 90 Field wiring Diagram POWER 24V 16A 3 gt FUSE 20 30 VDC LOW VOLTAGE 90 POWER Figure 3 d GND Power The metal connection from power line ground to system case ground should always be connected to protect the case from floating off ground Unless there is already a connection between earth ground and PT2060 case d POWER INPUT Input voltage it could connect with 24VDC 110VDC 110VAC and 220VAC according to the back panel label Refer to the following field wiring diagram for connection options d FUSE 24VDC 24V 16A 110VAC 110V 6A 110VDC 110V 6A 220VAC 220V 4A d GROUND System case Refer to item 1 fo
9. wer supply modules are needed The PT2060 power supply module is a half height module meaning PT2060 90 modules will fit in one slot The PT2060 90 POWER module should be installed in the first slot from the right If only one module is used it should be installed in the top half slot AR PT2060 90 will supply power to all the process modules The power module can gece accept most power supplies in the field and converts them to voltages acceptable for use by other PT2060 modules Figure 1 It is highly recommend to utilize UPS power supply for reliable monitoring operation Specifications Electrical Power inputs 24 VDC From 20 to 30VDC 16A 110VDC From 88 to 140VDC 6A 110VAC From 85 to 132VAC Frequency from 47Hz to 63 Hz 6A 220VAC From 175 to 264VAC Frequency from 47Hz to 63Hz 4A LED Indicators OK green Approvals CE CSA Non incendive class div 2 Grps ABCD T4 Ta 40 C to 75 C Certificate Number 2011996 ProvibTech Phone 1 713 830 7601 Fax 1 281 754 4972 sales provibtech com www provibtech com 4 PT2060 90 POWER Power Supply Module Environmental Temperature Operation 20 C 65 C Storage 40 C 85 C Humidity 95 non condensing Physical Each module comes with two components the front panel assembly and the back panel assembly Dimensions 120mm 4 7in x 49 5mm 1 9in A maximum of two PT2060 90 modules can be installed per PT2060 99 System Rack The location of