Home
SLP-C45 User`s Manual
Contents
1. Chapter 1 INTRODUCTION gt gt The following screen appears gt Select Start Menu Group Note e To change the start menu folder enter the new folder name 9 Click the Next gt button gt gt The following screen appears 2 Start Installation 10 Click the Next gt button gt gt The following screen appears gt Installation Complete 11 Click the Finish gt button gt gt When the installation is completed successfully the screen will return to the Windows screen Chapter 1 INTRODUCTION Note e Installation of Adobe Reader If Adobe Reader is not installed on your personal computer install 1t using either of the following procedures e Download Adobe Reader from the Adobe Systems home page 1 8 Chapter 1 INTRODUCTION 1 4 Installing the USB Loader Cable Device Driver A device driver must be installed before using the USB loader cable Follow the procedure below to install the device driver E Installing the device driver 1 Handling Precautions e Be sure to follow the procedure below when installing the device driver The USB cable may not be recognized if the procedure is not followed If the cable is not recognized uninstall the driver and then install it again e Administrator privileges on the computer are required for driver installa tion Installation should be done by the administrator or by a user who belongs to the administrator group The USB l
2. details displayed on the personal computer or devices or the state of a device after an operation Ctrl key a key Indicates keys on the keyboard Ctrl a keys Indicates the operation of pressing the a key while the Ctrl key is held down Unpacking Check the following items when removing the SLP C45 from its package 1 Check the model No to make sure that you have received the product that you ordered 2 Check the SLP C45 for any apparent physical damage 3 Check the contents of the package against the packing list to make sure that all accessories are included in the package After unpacking handle the SLP C45 and its accessories taking care to prevent damage or loss of parts If an inconsistency 1s found or the package contents are not in order contact your dealer immediately SLP C45 System disc SLP C45J60 1 CD ROM O In addition to the SLP C45 O program this CD contains the C 5 SLP C35 engineering tool for the SDC15 25 26 35 36 USB loader cable CEA A BE User s Manual CP UM 5458E 1 This manual The Role of This Manual A total of five different manuals are available for the SDC45 46 Read them as necessary for your specific require ments If a manual you require is not available contact Yamatake Corporation or its dealer Additionally you can download necessary manuals from http www yamatake com SDC45 46 Digital Indicating Controller Installation Instructions Manual No CP UM 544
3. loop 2 Cool MY loop 2 AT step loop 1 MODA AAN AT step loop 2 e Menu configuration list File Quit Quits the monitor window Ctrl q Numeric Numeric ae Starts stops the monitor Ctrl m Monitor M Start Stop M Option Setup Displays the Setup window O Command Line C Displays the Command Line window Trend Changes the display to the Trend o Monitor Help o Version A Version A Displays the version information the version Displays the version information Chapter 4 MONITORING O Trend monitor screen gt Trend monitor File Trend monitor Option Numeric Monitor Help 00 00 00 00 00 00 8 v 1 Pv1 0 v 2 My1 0 Y 3 SP1 D lJsHmyvi o l s cmyvi 0 0 J6 Pv2 O L17 Mv2 e s sP2 e Jo H mv2 eL J10 C Mv2 1 11 CT1 12 CT2 B Jis ur _ 14 UF o 15 UF e Ji6 ur elvEvi alvlEv2 D Ev3 D 4 Ev4 OlvJEVS e Menu configuration list A AT Quits the monitor window Ctrl q Trend Trend a Starts stops the Trend Monitor Ctrl t monitor Start Stop T Clipboard Outputs an image of the graph to Ctrl c Out the windows Clipboard Displays the Setup window Numeric Changes the display to the Monitor Numeric Monitor Help Version A Displays the version information Chapter 4 MONITORING e Icon list Icon Description DOM Views the graph atthe stan tme 4 Views the graph segment 172 sorento the
4. 1 Handling Precautions e The monitor target is limited to only one unit when monitoring is done via the loader jack on the front panel O Adjustment function This function is used when the user adjusts controller input For details on the adjustment function refer to gt SDC45 46 Digital Indicationg Controller User s Manual for Installation and Configuration CP SP 1218E 1 Handling Precautions e Our guarantee does not cover problems caused by incorrect settings made by the customer To reset the SDC to the factory default settings during adjustment select Option Initilize calibrate parameter to factory value from the pull down menu This will discard the user s settings and restore the factory defaults If this is mistakenly done during adjustment all user settings will be lost 1 1 Chapter 1 INTRODUCTION 1 2 System Requirements The following operating environment is required for using the SLP C45 MW Hardware Personal Computer Target model Operating system Serial Port Peripheral Devices Hard disk drive CD ROM drive Pointing device Description PC AT compatibles with a Pentium chip or higher 500 MHz or more 32 MB or more Windows2000 Professional XP Vista 32 bits 1 port or more 1 port or more When use the CMC10L 1024 X 768 dot or more 16 bit color or more Hard disk with at least 40 MB of free space 1 drive or more Windows compatible mouse or equivalent device Chapter 1 INTROD
5. Found New Hardware Wizard Please wait while the wizard installs the software J Yamatake USB Loader Comm port Yeslp sys To C WINDOWS system32 DRIVERS gt gt When the device driver installation is complete the following window appears Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for J Yamatake USB Loader Comm port I Click Finish to close the wizard 1 13 Chapter 1 INTRODUCTION AAA aT 4 Click Finish gt gt When the installation is complete the notification shown below appears on the task tray and Windows now correctly recognizes the USB loader cable 5 Select Control Panel gt System gt Hardware gt Device Manager for Windows XP 2000 and find the port number for the Yamatake USB Loader Comm from Ports COM 4 LPT Device Manager Em TS E y E S HIRA 9EFBA3B1DA E Batteries H Computer 8 Disk drives Display adapters E DYD CD ROM drives 9 Floppy disk controllers de Floppy disk drives 4 2 IDE ATAJATAPI controllers H Keyboards 8 Communications Port COMI Communications Port COM2 oY Printer Port LPT1 oY Yamatake USB Loader Comm port COM3 ER Processors amp SCSI and RAID controllers E Sound video and game controllers gs Storage volumes 6 Start the SLP select Menu gt Option and set to the communications port number
6. Indicating Controller Manual No CP UM 5458E This manual This manual is supplied with the SLP C45 Smart Loader Package The manual describes the software used to make various settings for the SDC45 46 using a personal computer Personnel in charge of design or set ting of a system using SDC45 46 must thoroughly read this manual The manual describes installation of the software into a personal computer oper ation of the personal computer various functions and setup procedures 11 Organization of the Manual This manual is organized as follows Chapter 1 Chapter 2 Chapter 3 Chapter 4 Chapter 5 INTRODUCTION Be sure to read this chapter before you start using the Smart Loader Package This chapter describes the required operating environment for the personal computer tells how to install the package and briefly introduces its features STARTING AND QUITTING THE LOADER This chapter describes how to start and quit the loader SETUP This chapter describes how to set up the data MONITORING This chapter describes how to change the settings as well as the screens monitoring the operation status TROUBLESHOOTING This chapter describes error messages that are displayed when a problem occurs and tells how to remedy the problem 111 Contents Conventions Used in the Manual Unpacking The Role of This Manual Organization of the Manual Chapter 1 1 1 1 2 1 3 1 4 Chapter 2 C
7. Installing the software for your Toaster device Software Installation Continue Anyway STOP Installation Chapter 1 INTRODUCTION 4 Click the Continue Anyway button gt gt The installation program then starts up and after it is completed the follow ing screen appears Yamatake USB Loader Cable Driver Installer Congratulations The drivers were successfully installed on this computer You can now connect your device to this computer IF your device came with instructions please read them first Driver Name Status y Yamatake YCsIp USB Ready to use 5 Click Finish button to complete the installation 2 Insert the USB loader cable into the USB port gt gt When Windows recognizes the USB cable the notification shown below appears on the task tray and the driver installation wizard appears Found New Hardware X USB Serial Controller Chapter 1 INTRODUCTION 3 Install the device driver 1 Usually when Windows recognizes the USB loader cable the window shown below appears In some cases depending on the Windows environment it may not appear Select No not this time and click the Next gt button Found New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation CD or on the Windows Update Web site with your permission Read
8. OFF e Make sure that the Decimal symbol has been set to for Control Panel Regional Settings gt Number If it has been set to some other character the loader program cannot function correctly Example for Windows XP go to Control Panel Date Time Language and Regional Options Regional and Language Options Regional Options Customize Decimal symbol Select and click OK button E Starting the loader Double click the SLP C45 SDC45 46 icon on the desktop or click the Start button at the lower left portion of the screen and select Programs SLP SLP C45 gt gt The SLP starts up and the menu window is displayed Note e For operating system details and mouse setup refer to the user s manuals provided with Windows NW Quitting the loader o Click the E icon at the top right of the screen or selecting Menu Quit gives the same result 2 1 Chapter 3 SETUP 3 1 Setup Function E Overview The setup function allows the user to set various parameters required for operation and write these parameters to the SDC so that it functions according to the user s particular control requirements When the SDC is used for the first time it will not function as required unless it is set up by using this setup function Parameters such as SP set point and control constants PID values that are changed relatively frequently while the SDC
9. is used Station Set the station sub address O to 127 DIN sub address when a CMC10B for example is used 1 Handling Precautions e When a user defined address is specified make the decimal point setting manually e Digital trend Setting Item Setting Range Address of parameter 256 to 65535 Number of bits in parameter Oto 15 Name Name of parameter Up to 10 alphanumeric characters 4 7 Chapter 4 MONITORING e Selecting trend monitor colors Numeric Monitor Trend Monitor Trend Monitor individual Digital Trend Monitor Trend Monitor Digital Trend Bice Dic Ate Ds B Bi 8G Sz Bl Beer Bl B D Bex O Car Os 8 BG Cac Ca When selecting Graph 1 to Graph 16 the color selection screen will appear Select a desired color Clicking Default will return the color setting to its initial value Numeric Monitor Trend Monitor Trend Monitor individual Digital Trend Monitor Trend Monitor Color Trend option Trend save folder Mireia Log data number 60000 Trend save folder Specify a folder in which to save the sampling trend data Log data number Select the number of trend data logs from the list below 5000 10000 30000 60000 Initial value 4 8 Chapter 4 MONITORING O Starting data sampling When setup 1s complete start the trend monitor Click the B icon Selecting Trend Monitor Tr
10. name This file name is not valid An invalid file name was input Input a correct file name error This file cannot be found Nonexistent file or wrong directory Input an existing file name Make sure that the correct path and filename are given This filename is a reserved A file name reserved for the device Input the correct file name and device name name is input directory Use a different filename Disk error Not enough free space on disk The disk free capacity is insufficient Free some disk space The device is not ready The disk drive is not ready Insert a disk and try again Cannot make file The CD ROM was specified as the Save the file to another location save destination File name too long The file name is too long Use 256 characters or less for the file name Path name The path does not exist An illegal path name was input Input a correct path name and try error Make sure that the correct path is again given File information Illegal file size The file is corrupt Corrupted file cannot be used error Illegal file information Create the file again Chapter 5 TROUBLESHOOTING 5 2 Other Troubleshooting Numeric values are not displayed If a decimal point symbol other than period Check that the decimal point symbol correctly is set the loader does not function correctly is period If not setitto period Note e period should be set as the decimal separati
11. obtained in the previous step Then press the OK button to complete the configuration Environment Setting VDODOODOOLGR USB loader cable auto select Device manager _ as Chapter 1 INTRODUCTION Note e If the CD ROM for the SLP is not available execute drvsetup exe on the computer on which the SLP is installed Then install the device driver Normally C Program FilesislpiSLPC45 E Uninstalling the device driver 1 Handling Precautions e Removing the driver requires restarting the computer Close other applications first and then uninstall the driver e Touninstall the driver administrator rights are required on the computer Uninstalling should be done by the administrator or by a user who belongs to the administrator group 1 Execute the driver removal program 1 Go to Control Panel gt Add or Remove Programs and click on Windows Driver Package Yamatake YC slp USB 04 19 2007 1 0 0 Click the Change Remove button Uninstall Driver Package 2 All devices using this driver will be removed Do you wish to continue 2 Click the Yes button 3 Restart the computer Chapter 2 STARTING AND QUITTING THE LOADER 1 Handling Precautions e Before starting the Smart Loader quit all other applications The program may not function if you start it while another application is running Set the power save setting infrared communications and screen saver to
12. to the loader plug might cause communications failure If this happens reconnect the loader plug correctly NOTICE Be sure that the user receives this manual before the product is used Copying or duplicating this user s manual in part or in whole is forbid den The information and specifications in this manual are subject to change without notice Considerable effort has been made to ensure that this manual is free from inaccuracies and omissions If you should find an error or omis sion please contact Yamatake Corporation In no event is Yamatake Corporation liable to anyone for any indirect special or consequential damages as a result of using this product 2008 Yamatake Corporation ALL RIGHTS RESERVED Conventions Used in the Manual The following conventions are used in this manual CJ Handling Precautions Handling Precautions indicate items that the user should pay attention to when handling the SLP C45 Note Notes indicate useful information that the user might benefit by knowing gt This indicates the item or page that the user is requested to refer to 1 2 3 Numbers within parentheses indicate steps in a sequence or indicate corresponding parts in an explanation OK button Indicates a selection button in screens displayed on the personal computer Option Indicates messages and menus displayed on the personal computer gt gt Indicates the result of an operation
13. 5E u This manual is supplied with the SDC45 46 Personnel in charge of design i and or manufacture of a system using the SDC45 46 must thoroughly read this manual This manual describes the safety precautions installation wiring primary specifications and transitions of key operations and displays For further information about operation refer to another manual Installation and Configuration SDC45 46 Digital Indicating Controller User s Manual for Displays and Settings Manual No CP SP 1265E The manual is a reference document necessary to set or change data The manual lists up the displays setup items setting ranges and initial values SDC45A 46A Digital Indicating Controller User s Manual for Installation and Configuration Manual No CP SP 1218E Personnel in charge of design manufacture operation and or maintenance of a system using SDC45 46 must thoroughly read this manual This manual also describes the installation wiring connections for communication all functions and settings of the SDC45 46 operating procedures troubleshooting and detailed specifications SDC45V 46V Digital Indicating Controller User s Manual for Computational Functions Manual No CP SP 1275E It describes the computation functions of the SDC45V 46V Please read it together with the Installation and Configuration manual CP SP 1218E and the Displays and Settings manual CP SP 1265E SLP C45 Smart Loader Package for the SDC45 46 Digital
14. ING 4 1 Monitoring Function HM Overview The SLP has the following two monitor screens e Numeric Monitor screen This screen is for performing operations such as changing settings or switching modes e Numeric display of the various RUN parameters parameters can be changed e Indicator lamps for the various operation modes lamp indications can be operated e Alarm display summary and detailed Trend Monitor screen This screen is for monitoring the RUN status of the SDC in the form of a trend graph e Screen display of trends for max of sixteen data items e Screen display of digital data trends for max of five data items e Export of sampled data as a CSV file e Trend screen saving e Data type PV SP MV user defined data all analog data that can be communicated e Sampling cycle 250 ms 500 ms Variable from 1 to 3600 s If the sampling cycle is 250 ms or 500 ms the screen displays a max of four data items and the display of digital data trends is disabled e Max sampling number 60 000 5 000 10 000 30 000 or 60 000 can be selected in the Setup Trend option window If the sampling count exceeds the maximum subsequent sampling data will be saved in the next file CSV comma separated value is a data format that can be handled by third party spreadsheet software such as Microsoft Excel With this format sampled trend data can be interpreted by spreadsheet software These screens can be use
15. Motor drive relay MFB input OD Inspection certificate O B Tropicalization treatment inspection certificate Outputs O L Anti sulfide treatment inspection certificate 0 None O Complying with the traceability certification O Z Tropicalization treatment Complying with the traceability certification O RiForm 1a relay O x Anti sulfide treatment Complying with the traceability certification O C Current output addition O PTransmitter power supply 0 None O D Continuous voltage output O 1 LEDs all orange 2 Set the mounting type control output input type power voltage and additional functions 3 Choose the desired selections for each item 4 Click the OK button 3 4 O Step 2 Initialize Chapter 3 SETUP 1 Handling Precautions e The type set here is a setting for the internal use of the loader program The model number of the SDC will not change even if the type is changed in the loader program Note e For an explanation of each of the specifications refer to gt SDC45 46 Digital Indicating Controller User s Manual for Installation and Configuration CP SP 1218E 1 Click the E icon Selecting File gt New or pressing the Ctrl n keys gives the same result gt gt The Initialize Data dialog box appears Information E o Initialize Data LD 2 Click the OK button gt gt A new file opens O Step 3 Set up the environment Before setting connect the USB loader c
16. No CP UM 5458E SLP C45 Smart Loader Package for the SDC45 46 Digital Indicating Controller User s Manual Thank you for purchasing the SLP C45 Smart Loader Package for SDC45 46 This manual contains information for ensuring correct use of the SLP C45 It also provides necessary information for installation maintenance and trou bleshooting This manual should be read by those who design and maintain devices that use the SDC45 46 and SLP C45 Be sure to keep this manual nearby for handy reference Yamatake Corporation RESTRICTIONS ON USE This product has been designed developed and manufactured for general purpose application in machinery and equipment Accordingly when used in applications outlined below special care should be taken to implement a fail safe and or redundant design concept as well as a periodic maintenance program e Safety devices for plant worker protection e Start stop control devices for transportation and material handling machines e Aeronautical aerospace machines e Control devices for nuclear reactors Never use this product in applications where human safety may be put at risk IMPORTANT Do not apply too much force when connecting the loader plug Doing so might damage the instrument x 1 Handling Precautions Application of excessive force
17. O Step 5 Save setup data When you have finished with the settings save them to a file Saving settings in advance and using saved settings greatly reduces the time required to set up the loader program The following items are saved e Type e Setup parameters 1 Select File gt Save As or press Ctrl a keys gt gt The Save As dialog box appears Save in LJ My Documents x o eao Pr Am Music d 2 my Pictures My Recent Documents Desktop My Documents My Computer My Network Save as type SLP C45 file c45 v 2 Enter the desired file name and click the Save button O Step 6 Download the settings Write the set parameters or parameters called up from a saved file to the SDC 1 Use the dedicated Smart Loader cable to connect the personal computer to the SDC 2 Turn the SDC on 3 Click the icon Selecting Communication Write SLP SDC from the pull down menu gives the same result gt gt The message Writing is going to be executed is displayed 4 Click the OK button gt gt This starts the writing of the setup parameters During writing the message Please wait is displayed When writing ends the message Normal end is displayed o Handling Precautions e If writing fails the message Communications error has occurred is displayed If writing is not possible refer to gt Chapter 5 TROUBLESHOOTING 3 7 Chapter 4 MONITOR
18. Tet views the graph segment 174 soreen to the lef Views the graph segment 174 screen to the right Views the graph segment 172 screen to the right Views the graph atthe latesttime E Rooms the graph out Imin Specify a time scale for the graph I 11min 2min 10min 1hr 12hrs 24hrs Auto e Zooming the graph Drag the mouse from the upper left portion to the lower right portion with the left mouse button pressed Trend monitor File Trend monitor Option Numeric Monitor Help ESB EMA adam o 00 00 00 00 00 00 0 v 1 Pv1 0 v 2 My1 0 v 3 sP1 Dllsmmvi ofs c mv1 oLje pv2 OL 7 MV2 8 SP2 e_3 HMVv2 10 C Mv2 01 11 CT1 12 CT2 13 UF 14 UF a 15 UF MB 16 0r 0 v ev1 allEv2 allEv3 DMEv4 OVevs e Canceling the zoomed graph Drag the mouse from the lower right portion to the upper left portion with the left mouse button kept pressed gt Trend monitor File Trend monitor Option Numeric Monitor Help ESA E dd 4d gt ADA mm 00 00 00 0 1 1 Pv1 eM2imv1 0 v 3 SP1 el4HMv ol sicmyvi o o pva OL 7 MV2 8 SP2 e_s HM2 10 C mMv2 11 CT1 12 CT2 13 UF 14 UF a l 15 UF _ 16 UF 0 v Ev1 allEv2 allEv3 D MEv4 OMlEvS 4 4 Chapter 4 MONITORING 4 2 Method of Operation E How to operate the numeric monitor screen O Start of monitoring start of communications The operation described below is required to start monitoring Otherwise monitori
19. This program is protected by copyright law and international treaties Unauthorized reproduction or distribution of this program or any portion of it may result in severe civil and criminal penalties and will be prosecuted to the maximum extent possible under law Chapter 1 INTRODUCTION 3 Click the Next gt button gt gt The following screen appears SOFTWARE LICENSE AGREEMENT PLEASE READ THE FOLLOWING SOFTWARE LICENSE AGREEMENT CAREFULLY BEFORE CONTINUING NOTE YAMATAKE CORPORATION HEREINAFTER REFERRED TO AS YAMATAKE IS WILLING TO LICENSE THIS SOFTWARE TO YOU HEREINAFTER REFERRED TO AS THE USER ONLY ON THE CONDITION THAT THE USER ACCEPTS ALL OF THE TERMS CONTAINED IN THIS AGREEMENT BY CLICKING ON THE AGREE BUTTON THE USER AGREES TO BE BOUND BY THE TERMS OF THIS AGREEMENT IF THE USER DOES NOT AGREE TO THESE TERMS YAMATAKE IS UNWILLING TO LICENSE THE SOFTWARE TO v Dont agree 4 If you agree to the software license agreement and wish to install the program click Agree gt To abort the installation click Don t agree gt gt After clicking Agree gt the following screen appears 2 Get Registration Information Please enter the name and company ofthe registered owner of SLP C45 SDC 45 46 into the fields below All fields must be filled in to proceed Name pe Company lt Back Cancel 5 Enter the user name and company name of a registered user
20. UCTION E Hardware configuration O General configuration SDC45 46 OOOH DUE WOE LLU TLU CLARA ABA BRA BRA BREDA E WMO TR tn NS Communications USB loader cable accessory O Configuration with CMC10B L e When connecting up to 31 units When connecting 31 or fewer SDC units use the CMC10L communication controller sold separately The CMC10L can convert data for interchange between RS 232C and RS 485 If the connected computer has a 3 wire RS 485 communications port the CMCIOL is not necessary Max 31 units e When connecting 32 units or more When connecting 32 SDC units or more use the CMC10L and multiple CMC10B communication controllers sold separately CMC10L_ CMC10B Max 31 units Max 31 units Max 31 units Note e Personal computers used for confirmation of hardware configuration IBM ThinkPad A31 Chapter 1 INTRODUCTION 1 3 Installing the Loader Install the SLP C45 on the PC hard disk Keep the installation CD as a backup This section describes how to install the SLP C45 on a personal computer 1 Handling Precautions e The CD does not contain an operating system OS and cannot be used on a PC that lacks an OS e If you start the installer while another application is runni
21. able to the computer Set the communications port and font on the personal computer 1 Click the amp The operation is the same by Selecting Option Environment Setting or pressing the Ctrl e keys gives the same result icon gt gt The Environment Setting dialog box appears Environment Setting Communication Port Communication Setup Font size 9 Port COMI O Port COM2 O Port coma O Port COM4 O Port coms O Port come O Port COM O Port come USB loader cable auto select Data Length Parity Stop bits even parity Transmission speed 4800bps 9600bps 19200bps 38400bps Fixed Cell Width O Port como O Port COM10 O Port COM11 O Port COM12 O Port COM13 O Port COM14 O Port COM15 O Port COM16 7 bit 8 bit Use Loader Cable OF O Use CMCIOL Os O Use CMC10B O9 Station address Station sub address Station address Station sub address 1 stop bit odd parity no parity 2 stop bits J 2 To set the optimum communications port automatically click the USB loader cable is automatically selected button 3 Select the desired font size 4 Click the OK button Chapter 3 SETUP 1 Handling Precautions e AE Normally use the port that was selected after you clicked the USB loader cable is automatically selected button Even if another communications port can be selected it sometimes cannot be used depending on its characteristics e Normally sele
22. an be used when Environment Setting Communication Setup gt Connect via CMC10 is selected Connect the loader cable to the CMC10B L Up to eight groups can be monitored 4 6 Chapter 4 MONITORING E How to operate the trend monitor O Setup Select Trend Trend monitor individual and Digital trend under Option O Setup and make the following settings for each data sample 1 to 16 The cycle and display upper lower limits are common to all channels e Trend Setting Item Setting Range E Setting of sampling cycle 1 to 3600s Display low limit Lower value of vertical axis of 1999 to display upper of left axis screen display limit Display high limit Upper value of vertical axis of Display lower limit to 1200 of left axis screen display 9999 Display low limit Lower value of vertical axis of 1999 to display upper 10 of right axis screen display limit Display high limit Upper value of vertical axis of Display lower limit to 110 of right axis screen display 9999 e Trend monitor individual Setting Item Setting Range Factory Setting Data type Type of sampled data Coe ee ee o E D 13 User defined data Axis Specify an axis used for the graph O Left 1 Right User defined Address of relevant parameter Address of communicable 256 address when the data type is set as parameter user type Station address Set the station address when a O to 127 1 CMC10B for example
23. and then click the Next gt button gt gt The following screen appears E Display Registration Information This sofware has already been installed by the following person Ifyou are not licensed to use this sofware you may not install this software onto your computer Cancel Chapter 1 INTRODUCTION EA AA O A A A st A AAA 6 Click the Next gt button gt gt The following screen appears 2 Choose Destination Location Setup will install SLP C45 SDC 45 46 in the following folder To install into a different folder click Browse and select another folder You can choose notto install SLP C45 SDC 45 46 by clicking Cancel to exit Setup Note e To change the installation destination directory click Browse 7 Click the Next gt button gt gt The following screen appears gt Select Components In the options list below selectthe checkboxes for the options that you would like to have installed The disk space fields reflect the requirements of the options you have selected POF file japanese V PDF filefenglish Disk Space Required Ook Disk Space Remaining 45295983 k Back Next gt i Cancel Note e Check the necessary files To display a PDF file it 1s necessary to install Adobe Reader For details refer to gt Note on page 1 8 8 Check put a check mark net before the software components you wish to install and click the Next gt button
24. cation O Copying a graph to the Clipboard The trend monitor screen display can be directly copied to the Windows Clipboard as a screenshot 4 9 Chapter 5 TROUBLESHOOTING 5 1 Error Messages and Remedy E Setup error messages Loader system Can t start up three or more SLP Three or more loaders are started Click OK button error C45s at once at the same time E Communications error messages Communications Timed out eNo signal was received within the eCheck the cable connections and required period of time contacts eA device other than the SDC is eConnect the PC to the SDC connected The SDC unit is not connected Cannot open communications port The communications port could not Do not run the loader and an other be opened application that uses the communications port at the same time Communications error has A system error occurred Try again or quit the loader and occurred restart Windows Trend monitor is active The requested action is not possible Stop the trend monitor and try again while the trend monitor is running SDC45 46 Cannot support currently Wrong loader program version for Contact Yamatake Corporation or status error connected SDC45 46 this SDC unit its dealer Loader lock or Communications The data cannot be loaded from the Cancel the loader lock or password lock loader because the loader is locked and try again or the password is set E File error messages File
25. ct Use Loader Cable O Step 4 Set up the SDC45 46 parameters Set each of the parameters required for running the SDC Move the cursor to the target channel for each setup item and do the following e When the setting is a numerical value Enter the numerical value and press the Return key e When the setting is selected by a number Press the right mouse button right click on a setup item The list of settings you can select will appear Select a desired item to complete the setting 1 Handling Precautions e is displayed within the cell if setup of a parameter is not required or is prohibited by previous settings The parameter cannot be set If neccessary re check the type setting or other related settings e About connection to the personal computer Normally the controller is connected to the personal computer with the dedicated cable By selecting Option Environment Setting and setting Communication Setup to Use CMC10L or Use CMC10B the controller can be connected through the CMC10B L In this case the environment setting and communication setup on the controller main unit must be configured beforehand Configure the controller settings in the offline mode with the cable not connected to the controller Note e For details on functions refer to gt SDC45 46 Digital Indicating Controller User s Manual for Installation and Configuration CP SP 1218E 3 6 Chapter 3 SETUP
26. d to perform the following operations e Monitoring of RUN status and changing of parameters on the Numeric Monitor screen e Switching of the RUN mode on the Numeric Monitor screen e Tuning of control constants on the Numeric Monitor screen e Monitoring of trends and sampling of data while the SDC is running e Monitoring of alarm status on the Numeric Monitor screen E Before use 1 Before starting to monitor connect the SDC to the computer using the USB loader cable 2 To display the monitoring screen click Monitor in the menu window 1 Handling Precautions e When setting up or operating the monitoring function using the loader program connect the dedicated cable e Before starting the Trend Monitor configure suitable monitoring settings e The sampling cycle sometimes shifts due to fluctuations in the communications cycle To perform measurement at exact times use a special recorder or data logger 4 1 Chapter 4 MONITORING 4 2 Screen explanations O Numeric monitor screen gt SLP C45 Monitor Screen Numeric Monitor ON Trend Monitor OFF File Numeric Monitor M _ Option O Trend Monitor T Help Bash g Numeric Monitor Item Numeric Monitor RUN reaoY RUNA READY2 Tagname AUTOS manuali AUTOZ manuala Epi rop 0692 rsr2 Auto Tuning Auto Tuning LSP number RUN READY LIHI AUTO MANUAL MI AT LSP RSP Heat MY loop 1 LT Cool MY loop 1 LHII Heat Mv
27. end Monitor Start gives the same result gt gt Data sampling starts and a graph of the specified parameters is displayed on the screen e Once the trend monitor starts it continues until a stop command is received or until the data for 60 000 cycles is sampled e If no stop command is received old data is overwritten as neccessary until data sampling for 60 000 cycles is complete e The screen can be changed to the Numeric Monitor screen while the trend monitor is running However the loader program cannot be shut down and the screen cannot be changed to the Setup screen It is necessary to quit the trend monitor first O Stopping data sampling Select Trend Monitor Trend Monitor Stop gt gt The trend monitor stops running O Saving sampled data The data sampled using the trend monitor can be saved to a file in CSV format The sampled data saved in CSV format can be processed using spreadsheet applications such as Microsoft Excel Files are named on the pattern log Y YYYYDDHHMMSS csv example log_2 20070307153019 cvs and are stored on the PC in the folder in which the SLP is installed The destination folder can be changed in the Trend save folder trend option setting window 1 Handling Precautions e Data that has been saved to a file is retained on the personal comput er until it is removed However data saved to a file cannot be redis played in the loader program To display it use a spreadsheet appli
28. ent Step 4 Set up SDC parameters Step 5 Save setup data Step 6 Download the settings 1 Handling Precautions e Steps 1 to 5 are required before the setup parameters are written to the SDC Be sure to perform these steps Otherwise the SDC may be set up incorrectly For example the required setup items may not be displayed or unneeded items may be displayed e Step 6 before the download connect the controller to the computer using the USB loader cable O Step 1 Set the Smart Loder type Set the loader program type to match the SDC model number 1 Click the T icon Selecting Option Type Setting or pressing the Ctrl t keys gives the same result gt gt The Type Setting dialog box is displayed gt Option C454241C000000 Basic model1 No Power supply Output 7 C45 48 96 A100 to 240 Vac 0 None O C46 96 96 O D 24 Vdc Basic model2 No Outputt 2 OA Standard 1 1 form 1a1b relay 2 2 form 1a relays Option Output3 4 ae OV Computation CO Current output O 2 DI2 D08 O DO Continuous voltage output 3 DI2 DO8 RS 485 Input model ep O0 7 digitmodel O VOYoltage pulse output O 5 CT2DI8 PRADO O RR 2 form 1a relays O 6 0T2 DO8 a E En CC 2 current outputs O T CT2 DOB RS 485 id a O W 2 voltage pulse outputs Addition O Cv Current voltage pulse DiNone P O T Tropicalization treatment O SS Motor drive triac MFB input O K Anti sulfide treatment O R1
29. hapter 3 3 1 3 2 Chapter 4 4 1 4 2 Chapter 5 5 1 INTRODUCTION OVGIVIOW E E E EA PS DT AAA oe coe ees 1 1 NM Loader T nctionsaa rue a 1 1 System Requirements ooooocccccccccccocnanoccccccccccccccccccccoo 1 2 E Hardware AAA EAN 1 2 M Hardware configuration oooooococoooomommoccrccrorsomcccr coso 1 3 Installing the Loader ooooooooooooooocccccrrrrrccccrcarrcrrccroo 1 4 Installing the USB Loader Cable Device Driver 1 9 E Installing the device drivVer oooooooooooooooooomomor2rsrcccrr lt oo 1 9 ei Uninstalling the device driVer oooooooooocoooooooooooo 1 15 STARTING AND QUITTING THE LOADER M Starting the loader oooooooooccoccrormmmmssrossorcrrrcr lt rr co 2 1 E Quitting Iheloader nen need 2 1 SETUP Setup FUNCHON zeun u0 80 ran naeh hasst 3 1 Oi sessao ans re nee eee ser 3 1 M Screen explanations lt oooooomoomoronanosorcsorcanosor9ssssaso 3 1 Method of Setup oooooooccoccccrccccocccaccccaoccor coco roo nn n ernennen 3 4 MONITORING Monitoring Function oooooocccccoroococccrccrroccccccccrrcrr ccoo 4 1 M Overview susanne Re rer ARAN 4 1 M Screen explanations lt ooooooooocoronaroorcrorcanssrossrnano 4 2 Method of OperatioN ooooooocococccconccccconocacconocccconoccco co 4 5 NW How to operate the numeric monitor screen 4 5 EH How to operate the trend monito
30. is running can also be set from the Smart Loaders monitor function screen With the setup function parameters that rare need changing once they are set are saved to a file in list format before the SDC is started and the saved file is called up and written to the SDC in a single operation NW Screen explanations O Menu screen ra SLP C45 Menu Help setup Monitor gt t q i mY E gt Et AL se 4 3 ty e Menu configuration list E Displays the Setup window Ctrl s Ff Monitor Displays the Monitor Trend Ctrl m window Jesiraton Displays ne Adjustment window TORII TT ontion E Changes the envionment setup Cuime faut Js te apncatn Cuma po vesna Displays the version information topa 3 1 Chapter 3 SETUP O Setup screen Toolbar Menu bar za Untitled SLP C45 A VV E Ba m 7 3 3 3 3 Ep o oe Selection window GH p3 MI fu po Message window 3 2 Parameter display area Chapter 3 SETUP O Menu configuration list fe fem om 2 Open Opens existing data Cirl o CI pe le Save As Saves the active data with a Ctrl a new name U u CSV Out X CSV Out X Saves the active data in CSV format Ctri x u HTML Out H H Saves the active data in HTML format Ctrl h Print Prints out the data Same contents as data saved in the HTML format Recent File Displays the recent file Quits the application Ctrl
31. ng the installer may malfunction Shut down other applications and then start the installer The SLP C45 sometimes cannot be started due to a particular combination of other applications and drivers For details on Windows and personal computer settings refer to the user s manuals provided with Windows and with the personal computer e Windows 2000 Professional XP Professional Only users belonging to the Administrators group can install uninstall this software Windows XP Home Edition Only users belonging to the computer Administrators group can install uninstall this software 1 Put the CD in the CD ROM drive of your personal computer gt gt The following screen appears for installing the driver for the USB loader cable and selecting a SLP model SLP C45 and SLP C35 2 SLP C45 SLP C35 install O Before install please do not connect USB loader cable Install USB loader cable driver Install SLP C45 for C45 46 Install SLP C35 for C15 25 26 35 36 Please select install program 2 Click the Install SLP C45 for C45 46 button gt gt The following screen appears 2 Welcome program This program will install 5 Welcome to SLP C45 SDC 45 46 Setup SLP C45 SDC45 46 on your computer itis strongly recommended that you exit all Windows programs before running this Setup Program Click Cancel to quit Setup and close any programs you have running Click Nextto continue with the Setup program WARNING
32. ng and rewriting of data cannot be performed e Click the icon Selecting Numeric Monitor Numeric Monitor Start gives the same result gt gt In normal operation The data on the SDC is displayed In case of an error The message Check the device to which the loader is connected is displayed Remedy according to Chapter 5 TROUBLESHOOTING The following operations are possible when the device and the loader are correctly connected O Monitoring of run state and changing of parameters Numeric monitor displayed Tag name in table format Process Variable PV Numeric group monitor Set point SP Manipulated variable MV Status monitor displayed RUN READY mode in lamp lighting status AUTO MANUAL mode LOCAL REMOTE status Auto tuning start stop status Self tuning start stop status ALARM mode Control output ON OFF status Event output ON OFF status Internal event ON OFF status DI terminal ON OFF status Operation Changes in SP value change numeric SP set change values are limited to those MV change in MANUAL mode shown PID value change RUN lt gt READY change AUTO lt gt MANUAL change Auto tuning start lt gt stop change About the operation mode RUN READY mode O RUN 1 READY AUTO MANUAL mode 0 AUTO 1 MANUAL 4 5 Chapter 4 MONITORING O Changing of data Enter the numerical value and press the Return key O Setting of user defined address Optional data not in the table can be registered t
33. ng symbol in the Windows con trol panel Example for Windows XP go to Control Panel Date Time Language and Regional Options Regional and Language Options Regional Options Customize Decimal symbol Select and click OK button 5 2 Revision History date uy 2008 CP UM 5458E 15 Edition azbil Yam at ake Corporation Specifications are subject to change without notice 08 Advanced Automation Company 1 12 2 Kawana Fujisawa Kanagawa 251 8522 Japan URL http www azbil com 1st Edition Issued in July 2008 W
34. o user configuration address UF 1 to 8 in the table Data can be read or written according to the data type e How to set user defined address 1 Select the Set monitor tag under Option O Setup in the pull down menu 2 Enter the address of the data to display according to SDC45 46 Digital Indicating Controller User s Manual for Installation and Configuration CP SP 1218E O Use of the command line Data can be read or written or the mode switched by directly entering communications commands on the command line 1 Handling Precautions e Transmission of the wrong command may result in problems for the SDC For this reason take care when describing command types addresses data and other information e For details on communications commands and data addresses refer to gt SDC45 46 Digital Indicating Controller User s Manual for Installation and Configuration CP SP 1218E e Loader lock must be canceled O Checking details of alarms You can check alarm details in the Alarm window when an alarm occurs e Click the ES icon Selecting Option Alarm gives the same result gt gt The details of the alarm that 1s occurring are displayed 1 Handling Precautions e This window displays the details of currently occurring alarms and cannot be used to reset the SDC alarm To reset the SDC alarm follow the instructions in Chapter 5 TROUBLESHOOTING O About the numeric group monitor The numeric group monitor c
35. oader cable is supported on Windows 2000 XP Vista 32 bit type It is not supported on 64 bit Windows XP or on Windows 95 Windows NT MS DOS or PC DOS e If there are multiple USB ports connect the USB loader cable to the same port every time If it is connected to a different port there is a chance that driver installation may be required again 1 Put the SLP CD ROM into the CD ROM drive of the personal computer gt gt The installation program is then started up automatically and the following screen appears 2 SLP C45 SLP C35 install Before install please do not connect USB loader cable Install USB loader cable driver _ es 4 Ter PER L Install SLP C45 for C45 46 Install SLP C35 for C15 25 26 35 36 Please select install program 1 Click the Install USB loader cable driver button gt gt The following screen appears Yamatake USB Loader Cable Driver Installer Welcome to the USB Loader Cable Driver Installer This wizard will walk you through updating the drivers for your Yamatake USB device To continue click Next i Cancel 1 9 Chapter 1 INTRODUCTION 2 Click the Next gt button gt gt The following screen appears Yamatake USB Loader Cable Driver Installer End User License Agreement lt Back J Next gt J Cancel 3 Select AGREE and click the Next gt button gt gt The following screen appears Yamatake USB Loader Cable Driver Installer
36. our privacy policy Can Windows connect to Windows Update to search for software O Yes this time only O Yes now and every time connect a device Click Next to continue 2 For the retrieval location of the device driver to be installed select the No not this time and click the Next gt button Found New Hardware Wizard This wizard helps you install software for USB Serial Controller your hardware came with an installation CD BB or floppy disk insert it now What do you want the wizard to do O Install from a list or specific location Advanced Click Next to continue CG Lie gt gt Retrieval of the device driver starts Found New Hardware Wizard Please wait while the wizard searches 2 USB Serial Controller 1 12 Chapter 1 INTRODUCTION gt gt When the device driver is found the following window appears Hardware Installation The software you are installing for this hardware Yamatake USB Loader Comm port has not passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly contact the hardware vendor for software that has passed Windows Logo testing 3 Click Continue Anyway gt gt Installation of the device driver starts
37. q Data Check Checks all setting values Ctrl d m E Makes a copy of the source Ctrl c Pastes the stored copy data Ctrl v Display MA Parameter disp area Displays the parameter display area NN Hint enable Enables hint display Auto size Enables auto cell size Size mialze riales the col siz R Edit Ma Input Output Displays the input output port Ctrl p Port setup setup screen Cell size adjust Matches cell size to the window Displays the graph Computation unit Displays the computation unit Only computation unit Communication Read SDC gt SLP Reads the device s data Ctrl r it ice R GLP Write SLP gt SDC Writes the data to the device Ctrl w W C45 46 Parameter initialize Restore SDC45 46 parameters to their factory settings it gt Displays the varioua items Type Setting Changes the type setup Ctrl t Environment Setting Changes the environment setup Ctrl e Help Help Displays the help F1 MEN Information Displays the handling precaution Clock setup Set the clock Only computation unit Version A Displays the version information 3 3 Chapter 3 SETUP 3 2 Method of Setup Do setup offline without connecting the USB loader cable to the SDC Click Option on the menu screen Do the following setup tasks Step 1 Set the Smart Loader type Step 2 Initialize clear previous settings Step 3 Set up the environm
38. r ooooocccocccccccccccco 4 7 TROUBLESHOOTING Error Messages and Remedy sseccccccccccccccsseesessseeeeees 5 1 M Setup error messages eee eee cece cece cette cece eee nennen nenne nenne 5 1 EH Communications error MESSAGES eee eee cee eee cree cree nee seen 5 1 E File error messages ooooooooococcccccrroccoccrccarocccccrccoso 5 1 Other Troubleshooting ooooooooccccccconooccccccccccccccccacooo 5 2 Chapter 1 INTRODUCTION 1 1 Overview The SLP C45 simply called the SLP from here on is a software engineering tool for the SDC45 46 simply called the SDC from here on The SLP runs on Windows 2000 Professional XP Vista simply called Windows from here on on a personal computer E Loader functions The SLP has the following functions e Setup e Monitoring e Adjustment O Setup function This function is for setting the required controller parameters on the personal computer and writing transferring them to the controller O Monitoring function After the setup parameters have been written to the controller 1t 1s possible to change and tune control constants while the controller is running to switch modes RUN READY AUTO MANUAL etc and to check RUN status and alarm occurrence The run state can also be checked on the Trend screen and sampled data can be output in CSV format so that it can be handled in third party spreadsheet software such as Microsoft Excel