1.   D    Electronic    Instruments    for the Life Sciences  made Inga  OPERATING INSTRUCTIONS AND  SYSIEM DESCRIPIION FOR THE  REL 08 B  ELECTRODE RESISTANCE METER          ELECTRODE RESISTANCE METER       REL 08 B       VERSION 1 3  npi 2014    npi electronic GmbH  Bauhofring 16  D 71732 Tamm  Germany  Phone  49  0 7141 9730230  Fax   49  0 7141 9730240  support Qnpielectronic com  http   www npielectronic com    REL 08 B User Manual    Table of Contents  ESTE SEE EE 3  2  NELLA OG  Busse 4  ENN 4  PAPE SD eri NUO oe UU    etic 4  25      Desenptiom Ob INE Front Pallas 4  2 1  Descriptionor the Rear Pai 6  25  System Bus  dnterconnectme EE 7  Di  COMING            NC         8    version 1 3 page 2    REL 08 B User Manual    1  Safety Regulations    VERY IMPORTANT  Instruments and components supplied by npi electronic are NOT  intended for clinical use or medical purposes  e g  for diagnosis or treatment of humans    or for any other life supporting system  npi electronic disclaims any warranties for such  purpose  Equipment supplied by npi electronic must be operated only by selected   trained and adequately instructed personnel  For details please consult the GENERAL  TERMS OF DELIVERY AND CONDITIONS OF BUSINESS of npi electronic  D 71732  Tamm  Germany     1     2     3     4      gt      GENERAL  This system is designed for use in scientific laboratories and must be  operated by trained staff only  General safety regulations for operating electrical devices  should be fol
2.  max  10 MO  Dimensions  305 x 180 x 105 mm   W x Dx H   version 1 3    page 8    
3. es a warm up period of 20 30 minutes is  sufficient     HANDLING  Please protect the device from moisture  heat  radiation and corrosive  chemicals     version 1 3 page 3    REL 08 B User Manual    2  REL 08 B   2 1  Components  The following items are shipped with the REL 08 B system   Electrode Resistance Meter  REL 08 B     User manual  System Bus cable         OF         2 2  System Description    The REL 08 B unit is designed to measure the resistance of micro electrodes  It only works in  combination with the EXT 02 B system  to which it 1s connected via the system bus     The measurement is performed by applying triangle voltage pulses through the system bus to  one of the headstages of a EXT 02 B system  The triangle pulses are transformed into square  current pulses in the headstage and applied to the electrode that 1s connected to the headstage   frequency approx  160 Hz   The voltage deflection caused by this current injection 15  recorded  sent back to the REL 08 B via the system bus and processed to get a direct reading  of the electrode resistance in MQ on the digital display  The system can be triggered manually  with a switch or via TTL pulse with an external device  An analog resistance monitor is  provided as well     Important  For correct resistance measurement make sure that the the EXT 02    15 powered  on  At the STIMULUS CONTROL of the EXT 02 B the switch has to be in OFF position and  no TTL HIGH input signal must be applied  Also the INPUT MODE switc
4. h of the EXT 02 B  must be in SINGLE or DIFF position    Also the NOTCH filter has to be turned OFF     2 3  Description of the Front Panel    REL 08 B ELECTRODE RESISTANCE METER npi    ELECTRODE RESISTANCE  MQ     POWER  ON    2 WA       d  i 1              or Sor  RESISTANCE CHANNEL  TEST    NE  SELECT    OFF       a                GROUND TTL IN OUTPUT  1V                        Figure 1  REL 08 B front panel view    version 1 3 page 4    REL 08 B User Manual    In the following description of the front panel elements  each element has a number that 1s  related to that in Figure 1  The number is followed by the name  in uppercase letters  written  on the front panel and the type of the element  in lowercase letters   Then  a short description  of the element is given      1  POWER LED    LED indicating that the EXT 02 B is powered on and that the REL 08 B is    POWER  properly connected to the EXT 02 B      2  POWER switch  optional     ON Switch for turning the REL 08 B ON  upper position  or OFF  lower position    If this switch is installed  the POWER LED   1  will only light up if the EXT 02 B  is properly connected and the switch is in ON position        OFF   3  RESISTANCE TEXT switch  Switch for enabling the resistance test function   upper position  resistance test 1s applied to the electrode selected with    the channel select rotary switch   5    lower position  resistance test not active  TTL enabled   7     ON  RESISTANCE  TEST       Important  For correct resis
5. lowed     AC MAINS CONNECTION  While working with the npi systems  always adhere to the  appropriate safety measures for handling electronic devices  Before using any device  please read manuals and instructions carefully    The device is to be operated only at 115 230 Volt 60 50 Hz AC  Please check for  appropriate line voltage before connecting any system to mains    Always use a three wire line cord and a mains power plug with a protection contact  connected to ground  protective earth     Before opening the cabinet  unplug the instrument    Unplug the instrument when replacing the fuse or changing line voltage  Replace fuse  only with an appropriate specified type     STATIC ELECTRICITY  Electronic equipment is sensitive to static discharges  Some  devices such as sensor inputs are equipped with very sensitive FET amplifiers  which can  be damaged by electrostatic charge and must therefore be handled with care  Electrostatic  discharge can be avoided by touching a grounded metal surface when changing or  adjusting sensors  Always turn power off when adding or removing modules   connecting or disconnecting sensors  headstages or other components from the  instrument or 19  cabinet     TEMPERATURE DRIFT   WARM UP TIME  All analog electronic systems are  sensitive to temperature changes  Therefore  all electronic instruments containing analog  circuits should be used only in a warmed up condition  1 e  after internal temperature has  reached steady state values   In most cas
6. s for connection of the REL 08 B to a  EXT 02 B system  Three EXT 02 B in slave configuration can be connected to one EXT 02 B  in master configuration  One electrode resistance meter  REL 08 B  and one audio monitor   AUD 08 B  can also be connected via this system bus      2  RESISTANCE           connector   This connector provides an analog output voltage corresponding to the measured resistance at  the electrode  Scaling at this output is I V MQ    While the resistance test 1s not active  the output voltage is 0 V    This output has the same functionality as the OUTPUT 1V MX2 connector  6  on the front  panel     version 1 3 page 6    REL 08 B User Manual    2 5  System Bus   interconnecting devices    Connecting multiple devices    The System Bus interconnects all amplifiers  EXT 02 B in master and slave configuration   and monitoring devices  REL 08 B  AUD 08 B   It provides both power lines and all signal  lines  The number of signal lines depends on the number of connected amplifiers    All devices of the B series  EXT 02 B  REL 08 B  AUD 08 B  have two SYSTEM BUS  connectors at the rear panel   5  Figure 2   To interconnect two or more devices  simply use  the provided cable and plug it into one of the SYTEM BUS connectors of each device    This will result in a chain of devices  which has a maximum length of six  1 x EXT 02 B  master  3 x EXT 02 B slave  1 x AUD 08 B  1 x REL 08 B   The order in which the devices  are chained up is not important  Since it is a bus s
7. tance measurement STIMULUS INPUT and NOTCH filter have  to be turned OFF      4  ELECTRODE RESISTANCE  MQ  display    This display shows the measured resistance of the electrode in MQ while  the resistance test is activated   XX XX MQ  max 10 MQ     ELECTRODE RESISTANCE  MQ     With inactive resistance test  the display will read 00 00 MQ          5  CHANNEL SELECT rotary switch    8 position switch for selecting the channel to which the electrode  resistance pulse will be applied         6  OUTPUT  1 V MQ  connector    This connector provides an analog output voltage corresponding to the   measured resistance at the electrode  Scaling at this output is I V MQ   O While the resistance test is not active  the output voltage is 0 V    This output has the same functionality as the RESISTANCE connector   2     OUTPUT  1V   MQ           the rear panel     version 1 3 page 5    REL 08 B User Manual     7  TTL IN connector    BNC connector for an external trigger signal  TTL  HI   resistance is measured      LOW   resistance 1s not measured        TIL IN   8  GROUND connector    Banana plug providing ground  The plug is connected internally to the shields of            BNC connectors     GROUND       2 4  Description of the Rear Panel    MONITORING    RESISTANCE  IV MQO    npi    A  AD                    Version RES 08B  Serial Nr    Date       Figure 2  REL 08 B rear panel view     1  SYSTEM BUS connector  see also chapter 2 5    50 pin connecter providing power lines and data line
8. ystem  all positions are treated equally     Channel addresses    When using monitoring devices  REL 08 B  AUD 08 B  it is important  that each recording  channel has its dedicated address  i e  that there is no more than one channel on a single  address number  This can be achieved by selecting a channel s address number with the  CHANNEL ADDRESS rotary switch  3  Figure 2  on the rear panel of the EXT 02 B in  slave configuration    The EXT 02 B in master configuration does not have a CHANNEL ADDRESS rotary switch   Its recording channels will always addressed to 0 for channel A and I for channel B  Therefore  the selectable addresses for the EXT 02 B in slave configuration begin at 2 and go up to 7   Each recording channel can be monitored either acoustically with the AUD 08 B or its  electrode resistance can be measured with the REL 08 B  These devices have a CHANNEL  SELECT rotary switch on their front panel  whose numbers correspond to the channel address  number selected at each channel of the EXT 02 B     Important  For correct resistance measurement make sure that the the EXT 02 B 1s powered  on  At the STIMULUS CONTROL of the EXT 02 B the switch has to be in OFF position and  no TTL HIGH input signal must be applied  Also the INPUT MODE switch of the EXT 02 B  must be in SINGLE or DIFF position    Also the NOTCH filter has to be turned OFF     version 1 3 page 7    REL 08 B User Manual    3  Technical Data    Output  range   10 V  impedance  50 Q  Display  XX XX MQ 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Fan Coil 42B Series  Manuel du propriétaire  User Manual-SRD-480D-SPANISH.indb  Eizo CH2 User's Manual  en cliquant ici  取扱説明書 - AQUA(アクア)|ハイアールアジア株式会社  1344 K2  Fiches outils AP CP CE1  Tableau prog  Une lecture de la lisibilité - Association Française pour la Lecture    Copyright © All rights reserved. 