Home
Manual - ArtFox Lighting
Contents
1. 5 7 DISPLAY SETTING 1 Press the ENTER button in DISY menu then enter to the display setting 2 Press the UP DOWN button to select LON 2 MINITES OFF 3 Press the ENTER button to escape and save 5 8 RUN THE AUTO RUN AUTO PROGRAMMING PROGRAM 1 Press the ENTER button in AUTO menu then enter to the running the auto run auto programming program 3 LIGHTING INSTALLATION MOUNTING HOLE FOR LAMP HOOK SAFETY CORD PICTURE ONE PICTURE TWO SUPPORT The lighting can be hanged at the high place with using the lamp hooks as showed in picture one Use the safety cord provided to pass through the handles and hang it as a second safety fixing Thelighting also can be used on the ground as showed in picture 2 Note gt Ensure support loading ability at least 10 times more than product weight and also make sure the lighting is installed steadily gt The lighting must be installed by the qualified personnel Please install it at the place where no one goes through 4 POWER SUPPLY CONTROL SIGNAL CONNECTIONS Make the XLR signal line connect with the lighting one port connects with the output port of lighting another one connects with the input port of another lighting Due to the output and input of the lighting keep connecting all the time so the DMX circuit still can be keep connecting when the power of certain unit occurs turn off XLR signal line only can be used in series connection pat
2. 5 CAL G GREEN 0 255 Calibration B BLUE 0 255 W WHITE 0 255 USE YES NO Channel mode 5CH 4CH OFF DIM DIML Dimming mode DIM2 DIM3 DIM4 ON DISY Permanent on Display set 2MIN 2 minutes off R RED 0 255 a ne G GREEN 0 255 B BLUE 0 255 Color temperature set a W WHITE 0 255 CT10 AUTO Auto ATOL RUN ATO5 RUN ATSP 0 255 second Auto speed CHS1 RUN CHS5 RUN R RED 0 255 G GREEN 0 255 S B BLUE 0 255 PROG SCO1 Program aci Scene 1 W WHITE 0 255 Chase 1 SHUT en TIME 0 255 second WAIT 0 25 5 second USE YES NO SC20 Scene 20 CHS5 Chase 5 SOFT ee 5 Vx x Software version xxR INFO LEDs xxG Information xxB xxW POW 7 100 80 50 Power reduction STL YES NO LOAD Setting load Load PRL an YES NO Program load REST YES NO Reset 4 SEND YES NO Send lustrations When the menu is set as the information of position the projector will be set automatically to be the main engine and then send data to external synchronously with the main engine Other projectors can receive these data and run It still be run according to these setting parameter even if power reconnection after power off When setting YES in ST L menu The parameter will bereset to be the factory default value as which with underline of a
3. Square Par 9 USER MANUAL Please read it carefully INDEX 8 DMX PROTOCOL 4CHS 5CHS 7CHS 10CHS Value Function fis SAFETY GUIDELINE sss ssceeescsscescecsscesscnccssscesssnccssscesssansscsssessenssoesssessasss o 2 ci i ci 0255 Tier ve TECHNICAL PARAMETER cerscscsssssscesescescscnscscscccnscscnscscsscscscssesesscsssssssesessees 3 can ene ue ere Gio Red CH2 CH3 CH3 CH3 0 255 Green 3 LIGHTING INSTALLATION ssssssesseeeeseescsecsseneecceseessnseeenseccsteeseeeseesesssssssseeee Qo Ss Ga GH aid aa oes 4 POWER SUPPLY CONTROL SIGNAL CONNECTIONS resssssssseeeeeeeeeseeeesseeeeeeeee 4 cH4 CHS CHS CHS 0255 White 5 OPERATION MENU eessrssseesssesseesceesesesseesseensessseeesesseeessesesesescessssesesseesesee n 5 o 22n S1 BUTTON OPERATION sissscscsesessscscvexdichcceeatesczeist aea aonadair ioa Taaa e 7 gug oue JTA EEA EE 5 2 DMX ADDRESS CODE SETTING etss sesrssrersssrsessarsesressrernnnressaarnarnessaarnareereannane iy 5 A 251 plecione SULEUCLEROs SIS UES og No effect 53 STATIC SETTING eritisi ikia bieo ii irois sira anioi a7 Ta HIRE madik 5 4 COLOR CAST CALIBRATION SETTING essessssesessseseeseseeescsseeeesseseeseesaeaeeseesesaeaaes 7 21 30 WHITE 2 3400K 55 CHANNELMODESETTING tescsstesdivscsesstasicusheotecesevsssbevseatbeathandececbessnanchendsasens ay oe 31 40 PUTTE 2 22008 41 50 WHITE 4 4900K 2 3 4 5 6 DIMMING MODE SETTING trrrrssssttsteseeesceetsessseeessessaeeeeeseeeeeesessaeeeeeeesesaaanee
4. bove chart 6
5. d SHUT 3 Press the UP DOWN button to set up the 0 255 numerical value 4 Press the ENTER button to escape and save 5 4 COLOR CAST CALIBRATION SETTING 1 Press the ENTER buttonin CAL menu then enter to the color cast calibration setting 2 Press the UP DOWN button to select RED GREEN BLUE WHITE 3 Press the UP DOWN button to set up the 0 255 numerical value 4 On the USE interface pressing ON button means valid otherwise OFF button invalid 5 Press the ENTER button to escape and save Illustrations When pressing the ON button which means valid on the USE interface the actual output value of RED GREEN BLUE WHITE is output in accordance with the percentage which the color cast calibration value divides 255 5 5 CHANNEL MODE SETTING 1 Press the ENTER buttonin CHMD menu then enter to the channel mode setting 2 Press the UP DOWN button to select 10CH 7CH 5cH C4cH 3 Press the ENTER button to escape and save 5 6 DIMMING MODE SETTING Illustrations When setting OFF in DIM menu there will be no delay dimming effect The dimming speed of DIMI DIM4 is from fast to slow It will be set OFF J automatically in DIM menu when showing the shutter effect 1 Press the CENTER button in DIM menu then enter to the dimming mode setting 2 Press the UP DOWN button to select OFF DIM1 DIM2 DIM3 and DIM4 3 Press the ENTER button to escape and save
6. es Biy oa 51 60 WHITE 5 5600K 5 7 DISPLAY SETTING Girotti aeeaiei E EEE EEE Bay G7 Be a 8 71 80 WHITE 7 6500K 5 8 RUN THE AUTO RUN AUTO PROGRAMMING PROGRAM sssseesseeeereeeeeees 7 81 90 WHITE 8 7200K 5 9 EDIT AUTO PROGRAMMING PROGRAM rrrtsssstessetettesentesseseeseeseneasesessesensenee 8 91 100 WHITE 9 8000K 5 10 CHECK THE LIGHTING INFORMATION eeeeeeeeeteereerreerssrreerrsrrneresrrenenseresrese 8 R 2 2 n 101 110 DE ES A ATO1 R G B RG RB GB 5 11 LIGHTING SETTING PARAMETER RESET sesrrererererresreresrreresererereeereerenrerennes 8 oe 121 130 ATOZ Rt R Gt G4 Bt Bs Wt Wd 5 12 PROG AUTO PROGRAMMING PARAMETER RESET i 8 131 140 ATO3 R G RIG R B R B BtGt BIGH 141 150 ATO4L R G B WT RIGIBIW 513 LIGHTING RESET esrrsssssessseessecsseecsstecssaeenseceseessaeecseesessarseseesereseateseeeessaeeeneass 8 ae FECES Smee E NCH PRSC NE IC RENCRT ACERT ESRI 5 14 LIGHTING PARAMETER DOWNLOADING EACH OTHER crrsssesseseeseeeeeeseeeees 205 tt 161 170 CHASE1 6 MAINTENANCE ceesecesccccccecscccccccccececcecccssccccsccescscescecesceccscescessscescssescesesceses O 171 180 CHASE2 Ts TROUBLESHOOTING lt lt sss eesssseeceessseececesessececcesssseceessssneeeessssssaeeesssseeeeses n Qo ese SHOES 191 200 CHASE4 8 DMX PROTOCOL cecesesccsccccscccccccccsccnccccnccccccccsccccsccccccccscssccccscccssscsssscscsscsess J0 201 210 CHAS 211 255 Reserved 0 255 S speed of auto run fast gt slow
7. ing is correct or not Check KCHMD setting is correct or not Please check whether the DMX line is near to the high voltage wire or not In that case it will damage or interfere the DMX electric circuit The beam appears Check whether the CAL is started or not and the set value is too dim the brightness small declines obviousl y Check whether the POW is in over temperature protection situation or not if yes please take measures for ventilation 9 1 SAFETY GUIDELINE Please keep this manual in a safe place for further reference Please make sure they also have this user manual if you sell this lighting to other users Every unit is packed properly by the manufacturer Please operate this lighting according to the user manual Any damage caused by improper use will not be assumed by the manufacturer When receiving the lighting please dispose the carton check and inspect there is any damage or not Should there be any damage caused by transportation do not use the lighting and consult your dealer or the manufacturer This lighting can be used indoors IP20 The lighting is only intended for installation and operation by qualified personnel Donot mount the lighting directly onto inflammable surface Ensure power supply voltage correspond to device requirements before running It is essential that each lighting is correctly earthed and that electrical installation conforms to all
8. relevant standards When the lighting is hanged to a high place please use a safety cord provided to pass through the lighting handles as a secondary safety fixing for safety seasons For details refer to LIGHTING INSTALLATION section Avoid direct exposure to the light from the lamp specially for people with epilepsy The light is harmful to eyes Do not project the beam onto inflammable surfaces The minimum distance between the lighting and irradiated object should be 1m Exterior surface temperature of the lighting willbe 65 C when working please do not touch it with bare hands To prevent electric shocking please do not touch the power cord when the lighting is running Never let the power cord mix with other cables The LED lens should be changed if deeply scratched or cracked There is no user serviceable parts inside the lighting Before using the device please check whether the covers or housing are well installed or not and whether the screws are installed firmly or not Do not open the housing and never operate the lighting with the covers removed Always disconnect a lighting from the power supply when the device is not in use or before cleaning it or before attempting any maintenance work Electrical connection must only be carried out by qualified personnel Please use the original packing material for second transportation Ifyou have any questions or suggestions please do no
9. ress the ENTER button to start running 5 9 EDIT AUTO PROGRAMMING PROGRAM 1 Press the ENTER button in PROGRAM menu then enter to the editing auto programming program 2 Press the UP DOWN button to select CHASEO1 CHASEOS 3 Press the ENTER button for confirmation and enter to the next menu 4 Press the UP DOWN button to select SCENEO1 SCENE20 5 Press the ENTER button for confirmation and enter to the next menu 6 Then press the UP DOWN button to select RED GREEN BLUE WHITE SHUT TIME waT USE 7 Press the UP DOWN button to set up the parameter which are needed 8 Press the ENTER button to escape and save Illustrations When USE is set to be NO or the TIME parameter of TIME is 0 it will not run this scene When WAIT is set to be FADE time the running process isas the right chart showing a X 5 10 CHECK THE LIGHTING INFORMATION 1 Press the ENTER button inf INFO Jmenu then enter to the checking the lighting information 2 SOFT button is for software version information 3 LEDs button is for the LED quantity information 4 POW button is for the current information of power reduction It is 100 output in normal conditions but 80 or 50 output in over temperature protection situation 5 11 LIGHTING SETTING PARAMETER RESET 1 Press the ENTER button in ST L menu then enter to the lighting setting parameter reset 2 Pres
10. s the UP DOWN button to select YES 3 Press the ENTER button to escape and save 5 12 PROG AUTO PROGRAMMING PARAMETER RESET 1 Press the ENTER button in PR L menu then enter to the PROG auto programming parameter reset 2 Press the UP DOWN button to select YES 3 Press the ENTER button to escape and save 5 13 LIGHTING RESET 1 Press the ENTER button in REST menu then enter to the lighting reset 2 Press the UP DOWN button to select YES 3 Press the ENTER button for confirmation of lighting reset 5 14 LIGHTING PARAMETER DOWNLOADING EACH OTHER 1 Press the ENTER J button in SEND menu then enter to sending parameter to other lightings 2 Press the UP DOWN button to select YES 3 Press the ENTER button to confirm sending 8 5 1 BUTTON OPERATION 1 MENU To return to the previous menu 2 ENTER Enter to the next menu or save 3 UP Menu selection or increasing the parameter aan 4 DOWN Menu selection or decreasing the parameter C o 3 io 5 2 DMX ADDRESS CODE SETTING IGRI EON ESAS 1 Pressthe ENTER buttonin ADDR menu then enter to the DMX address code setting 2 Press the UP DOWN button to select 1 512 numerical value 3 Press the ENTER button to escape and save 5 3 STATIC SETTING 1 Press the ENTER button in STAT menu then enter to the static setting 2 Press the UP DOWN button to select RED GREEN BLUE WHITE an
11. t hesitate to consult your dealer or factory 2 TECHNICAL PARAMETER Input Voltage AC100V AC240V 50 60HZ Power Consumption 90W Lamp Specifications 9 pcs four in one RGBW high efficiency 10W LED rated life 50000 hours Lens Angle 25 Optional 45 Spot Angle 40 Color RGBW linear color mixing Color Temperature color cast calibration setting color temperature output inside device Dimmer 0 100 linearly dimming 5 types dimmer modes smooth dimming flicker free Shutter independent electronic strobe Control Mode Standard DMX512 3 pin interfaces 4 channel modes Master slave mode no need to set up the master and slave manually will receive the main engine data automatically 5 auto running modes rainbow channel and rainbow effect Other Functions Self programming function 5 chases each chase has 20 scenes fade function Lighting setting data self programming data can be downloaded each other Temperature Control Protection both of lamp holder and base have temperature control protection Waterproof Grade IP20 Work Environment Temperature 20 C 40 C Net Weight 2 3Kg 236 5 mm 9 3 1 _ fs 112 2 mm 4 42 DIMENSION 133 mm 5 24 gt 192 22 mm 7 57 2 Press the UP DOWN button to select AT0O1 LKATO5 SPEED CHASEO1 CHASE05 3 P
12. tern the amount of the lighting can not be more than 32 PCS not available in parallel connection pattern Must add a signal amplifier if the length of signal line exceeds 60M between controller and lighting or between two lightings Inthe controller mode at the last fixture in the chain the DMX output has to be connected with a DMX terminator The DMX terminator is simply a connector witha resistor about 120Q OHM connected across pins 2 and 3 of the Canon plug please see the picture in the right It can prevent the noise and reflection caused by DMX 512 signal during transmission The transmission speed of DMX 512 signal is very quick It will affect the signal transmission if any damage of the signal line the weld is not firm or bad connection etc The connector with 3 pins XLR is more universal than the one with 5 pins XLR 3 pins XLR PIN1 GND PIN2 signal PIN 3 signal 5 pins XLR PIN1 GND PIN 2 signal PIN3 signal PIN4 PINS UNUSED There can t be more than 20 PCS of lightings for series connection pattern when using 220V AC it can t exceed 10 PCS lightings for series connection pattern when using 110V AC POWER IN 5y OPERATION MENU Tab Level 1 Level 2 Level 3 Level 4 ADDR 001 512 Address R RED 0 255 STAT G GREEN 0 255 Static control B BLUE 0 255 W WHITE 0 255 SHUT 0 255 R RED 0 25
13. utomatic reset of the other projectors after receiving parameter correctly 6 MAINTENANCE To prolong the life of lighting it is very important to do the maintenance work The environment is hash outdoors or if the lighting is idle for a long time damp dust can cause greater accumulation of dirt on its cover or housing So it should be cleaned to maintain an optimum light output and at the same time to prevent it from corrupted by dust and acid gas Cleaning frequency depends on the lighting operation frequency and the environment in which the fixture operates Soft cloth and typical glass cleaning products should be used for cleaning It is recommended to clean projector at least once every 20 days Do not use any organic solvent e g alcohol to clean housing of the apparatus 7 TROUBLESHOOTING PROBLEM REASON AND ACTION Check the power connection is correct or not The lighting can tbe Please detect the voltage started normally Power supply is damaged or incorrect connected Calla qualified personnel to fix it Connection of control board is not correct Call a qualified personnel to fix it Please check the DMX connector and the power connection is connected correctly or not It means having signal if it shows twinkling of the decimal point which in the lower right corner of the screen when exiting the screen saver Out of console s control Please check the DMX address setting of light
14. when AUTO 1 AUTO 5 effective ACCESSORIES Virtual colour wheel 5 CH8 0 255 0 10 No effect 11 Blue Blue full Red Green White 0 step 12 50 Red 0 Green gt up Blue full White 0 proportional 51 Light Blue Red 0 Green full Blue full White 0 step These items are packed together with the lighting please check 52 90 EE OE ee den ENEA 91 Green Red 0 Green full Blue 0 White 0 step Name Quantity Unit Remark CH9 92 130 Red gt up Green full Blue 0 White 0 proportional 131 Yellow Red full Green full Blue 0 White 0 step This manual 1 Pc 132170 Red full Green gt down Blue 0 White 0 proportional TTA Red Red full Green 0 Blue 0 White 0 step The power cord 1 Pc PAO Red full Green 0 Blue gt up White 0 proportional 211 Magenta Red full Green 0 Blue full White 0 step 212 250 Red gt down Green 0 Blue full White 0 proportional 251 255 Blue Red 0 Green 0 Blue full White 0 step 0 10 Use the dimmer mode which menu has set up 11 20 Dimmer off 20 Dimmer 1 am SEI 31 40 Dimmer 2 41 50 Dimmer 3 51 60 Dimmer 4 61 254 Use the dimmer mode which menu has set up 255 Reset Cat least 5S 1 0 Illustrations 1 Must disconnect the connection of projector and console before sending the parameter 2 The information of ADDR CAL can t be sent can t be downloaded each other 3 There will be an a
Download Pdf Manuals