Home

2210KL - scalenet.com

image

Contents

1. 122 F 10 C to 50 C Maximum Humidity 95 RH Physical Dimensions 2 sided Tray 4 sided Tray Width 24 610mm Width 27 686mm Depth 15 3 8 391mm Depth 15 3 8 391mm Height 3 76mm Height 3 76mm 2210KL Product Footprint 2210KL4 Product Footprint Width 25 1 2 648mm Width 27 686mm Depth 17 3 8 441mm Depth 17 3 8 441mm Height 5 3 8 137mm Height 5 3 8 137mm Weight 24 4 Ib 11 kg Weight 25 2 Ib 11 4 kg Certification Descriptions Pelstar LLC has been officially certified as the manufacturer of Health o meter Professional medical devices The Pelstar LLC quality assurance system covers the development production sales and service of medical scales and measuring systems 18013485 2003 CERTIFIED This product is tested to and meets the requirements of 1 CSA C22 2 No 601 1 M90 Medical Electrical Equipment Scale Disposal This Health o meter Professional scale must be disposed of properly as electronic waste Follow the national regional or local regulations which apply to you for disposal of electronic waste or batteries Do not dispose of this device in the domestic waste stream ASSEMBLY INSTRUCTIONS _ _ _ _ _ Before Assembly Each 2210KL 2210KL4 neonatal pediatric tray scale is shipped disassembled in one carton Carefully inspect the carton for shipping damage before unpacking If damage is found
2. LB GM display 11011 Moving the Scale The scale should be lifted by the two black handles only For your convenience an optional wheeled cart is available model 2210CART NOTE The scale tray should never be used for transporting a baby or objects The tray surface must be clear of any objects during transport 13 CALIBRATION Calibration Your scale has been factory calibrated and does not require calibration prior to use The following procedure should be performed only to correct any error in calibration Calibration is protected by a security code to avoid inadvertent access For maximum accuracy calibration must be done in grams If you only have certified weights in pounds convert them to grams i e 10 pounds 4536 grams Scale Calibration 1 Press the ON ZERO button on the console and wait for the display to show 0 0 2 Place an accurately known certified weight 3 000 to 5 000 grams recommended on the platform If the display reads other than the known weight value by 1 gram then the scale is out of calibration IMPORTANT NOTE A certified weight is a weight that has been accurately calibrated and its license is traceable to NBS weights amp measures Weight room free weights are not normally suitable to use as check weights as they may vary from their stated value 3 Remove weight from platform The calibration security code must be entered before attempting to calibrate the scale Hold the MENU b
3. at 1 800 815 6615 15 MAINTENANCE S Cleaning Procedures Proper care and cleaning of the scale is essential to ensure a long life of accurate and effective operation In addition to routine cleaning include a regular check of all structural apparatus All external surfaces can be wiped clean with a damp cloth A mild soap and water solution may be used as well Wipe unit dry with a clean soft towel DO NOT immerse scale platform into any liquids DO NOT use isopropyl alcohol other such solutions or sanitizing wipes to clean the display surface Do not use abrasive cleaners Check overall appearance of the scale for any obvious damage or wear and tear 16 WARRANTY SS O Limited Warranty What does the Warranty Cover This Health o meter Professional scale is warranted from date of purchase against defects of materials or in workmanship for a period of two 2 years If product fails to function properly return the product freight prepaid and properly packed to Pelstar LLC see To Get Warranty Service below for instructions If the manufacturer determines that a defect of material or in workmanship exists the customer s sole remedy will be replacement of the scale at no charge Replacement will be made with a new or remanufactured product or component If the product is no longer available replacement may be made with a similar product of equal or greater value All replaced parts are cove
4. contact your shipper or a Health o meter Professional representative immediately at 1 800 815 6615 Claims must be filed with the shipper as soon as possible after receipt of the package The following information details what you will find inside the main carton as you unpack the parts for assembly To prevent scratching any components carefully remove each assembly from the carton and unwrap the packing materials Set the carton aside for storage To avoid damaging the scale parts when unpacking do not use a box cutter knife scissors or any sharp object to open the protective inner packaging Parts List Carton 1 Scale platform 1 Acrylic tray 6 C cell Alkaline batteries 1 User instructions Tools Required Phillips head screwdriver not included Assembling the Scale This scale is powered by six 6 standard disposable C cell alkaline batteries Use the following procedure to install the batteries 1 Remove the scale top cover by removing the six 6 screws Fig 1a K 2 Locate the battery tray in the rear center of the scale C aN l platform It has a white cover that is held down with two N AS screws Remove the screws and battery cover 3 Insert new batteries Note the orientation that is shown on the bottom of the battery tray Figure 1a Remove Scale Cover 4 Replace the battery tray cover and screws Before installing scale cover press ON ZERO to ensure scale turns on 5 Reinstall the
5. function and deducts the weight of an object on TARE the tray Toggles the unit of measurement between Pounds and Grams in LB GM mode or Kilograms and Grams in KG GM mode See User Setting LB GM Options on page 13 for instructions on changing unit of measurement mode Secondary function is the up arrow and is used for menu selection REWEIGH Allows repeating weighing of the patient without stepping off the scale RECALL Recalls previous weight measurement Secondary function is the down arrow and is used for menu selection MENU Used for advanced programming functions Secondary function is the ENTER button and is used for menu selection OPERATING INSTRUCTIONS CONT Weighing a Patient 1 Press blue ON ZERO button Make sure 0 appears on display 2 Place baby on tray 3 Allow scale to lock onto the weight The scale will beep and display PRIOR WT when the weight is locked 4 Remove baby from tray Measurement value remains on the display until it is cleared 5 To clear the displayed weight and ready the scale for the next weighing press blue ON ZERO button The 2210KL scale comes standard with these features 1 Auto Zero The scale will automatically display 0 when turned on If the display reads between 20 gram and 20 gram at any time regardless of what is on the tray the scale will automatically reset to 0 after 8 seconds 2 English Metric Readout With normal operation
6. scale cover Start partially inserting the 6 screws Once cover is centered tighten screws fully 6 Place the scale platform on a table top with the display buttons facing you 7 The acrylic tray has a built in measuring tape Align the tray so that the rule is positioned over the back end of the scale platform Fig 1b Measuring Tape 8 Carefully lower the tray onto the four mounting pins on the scale platform When the tray is properly aligned with the pins gently push down on the tray over each pin until it snaps into its locked position When properly positioned there will be about a 3 8 space between the platform top and the bottom of the tray Always lift the scale by the black handles only FIUTA Lar nela ATAN never by the tray 68850 Health o meter Professional A y ENTER me RE Ce Screen Icons Icon Description E Indicates level of battery power remaining kg Indicates weight mode is in kilograms Ib oz Indicates weight mode is in pounds ounces gram Indicates weight mode is in grams NET WT Is displayed when a weight is tared PRIOR WT Is displayed after a weight measurement AVERAGE WT Is displayed when motion is detected during a weight measurement Keypad Buttons Note that some buttons perform multiple functions Function Description ON ZERO Press to turn scale on or reset to zero Used to perform the tare
7. you may switch the display units between grams or kilograms and pounds at any time before or after a weighing When turned on the scale will display the last used unit of measure 3 Tare Option An object weighing more than 30 grams can be subtracted from the total weight to determine the net weight 4 Weightlock Any weight over 512 grams will lock in so that no further weighings can take place until the weight is cleared by pressing ON ZERO The measurement will display even after the baby is removed from the tray so that the caregiver can attend to the baby first before recording the weight The value is retained in memory and can be reacalled even after the scale turns itself off 5 Motion Detection In most cases the scale will display a true accurate weight based on a series of consistent and stable measurements However if a baby or object is moving on the tray the scale may not achieve consistent readings that are required to give a stable weight This condition is indicated by Weightlock not activating on the display If the movement on the tray continues for seven seconds the scale will automatically activate the motion detection feature and the infant s weight and AVERAGE WT will be displayed Because of the movement on the platform average weight indicates that the scale was not able to achieve a true measurement in line with the listed accuracy specification However the average weight deviation from the true we
8. Health o meter Prof es sto na il Model 2210KL 2210KL4 High Resolution Digital Neonatal Pediatric Tray Scale E E as a um ua ca o o A 2210KL 2210KL4 User Instructions PELSTAR LLC 9500 West 55 St McCook IL 60525 7110 USA www homscales com Pelstar LLC 2017 P N UM2210KL 2210KL4 Rev20171218 Health o meter ProTres sto n a Model 2210KL 2210KL4 Thank you for your purchase of this Health o meter Professional product Please read this manual carefully and keep it for easy reference or training TABLE OF CONTENTS _ _ _ _ _ Ca tions a d Warning Ses ar e ud A EAA KARAR EREN A a ANAS 3 Specifications for This Scale e rrenaaeeeraanaaaaana 4 Certifications Connectivity Disposal eae 5 Assembiy INSIUCUONS xa raisa nen a ea a dando a a ea iee iaia 6 Operating Instructions soci ets Ncaeeed ecteaneet se oes attuned tora en eerste ants antoeste ten tths os eeeboaeties 8 Gre 9 lio g Peer eRe eee ere Pee SS Sd PE RST NE TMP TCE RO e dd 14 TIOUDIGS OO NO oe ce cade ees ease ches toes cectiadasestealianes a a a cada Sa ada nda ainda 15 MAINTENANCE ass e pai aaa non eee eet raara ana en Daaa oaa aaiae 16 WV AURA inh Ea Neda SNE edith kA nd and as e A enka gas a dace ol 17 Note This scale has been factory calibrated and does not require calibration prior to use Please register your scale for warranty coverage at www homsc
9. WT Figure 8 Motion detected during weighing Battery Life Indicators This scale has excellent battery life with most users getting more than two years from a single set of batteries Your battery longevity will vary with the frequency of use and the length of the Auto Off timer To help ensure you are never without the use of your scale the display shows the amount of charge left in the batteries Battery Icon Located in the bottom left corner of the LCD display is an icon of a battery With new batteries all three segments will be dark As the batteries become depleted the segments will turn off Flashing Battery When the battery icon is empty and the frame is flashing replace the batteries Fig 9 NOTE Properly dispose of old batteries Install six 6 new alkaline C cell batteries Do not mix new and used batteries See page 7 for battery replacement instructions E Figure 9 Battery Indicators 12 OPERATING INSTRUCTIONS CONT l User Setting Options Your scale has three additional settings that you may customize for your specific needs Tone on off A tone sounds whenever a weight is locked or a button is pressed Factory setting is on Unit lock The LB GM button can be disabled so that the scale will weigh in only the selected unit of measure Factory setting is unlocked Unit display The metric unit of measure may be displayed in Ib grams i e 2541 gram or lb kilogr
10. actory to shut down after one minute of inactivity This can be changed to any increment from 12 seconds to 25 minutes to suit your needs 1 Press ON ZERO and wait for the display to show 0 0 Do not place anything on tray 2 Hold the MENU button down and press the RECALL button Set 0 will be displayed along with the up and down arrows the 0 will be flashing 3 Press the A button repeatedly until Set 3 appears press ENTER 4 The Auto Off time currently programmed in the scale will display as minutes and tenths of minutes i e 03 2 the far left digit will be flashing Use the Mand buttons to set the desired value press ENTER to advance to the next digit For example setting the time to 00 5 will turn the scale off after 30 seconds of no use 02 0 will turn the scale off after 2 minutes 25 0 will turn the scale off after 25 minutes 5 Press ENTER when complete to save and return to normal weighing operation ENTER MENU Figure 7 Menu button 11 OPERATING INSTRUCTIONS CONT Motion Detection Motion detection uses a proprietary technology that automatically provides accurate weight measurement when there is motion on the tray If there was considerable motion during the weight measurement motion detection will activate after seven seconds and AVERAGE WT will be displayed along with the weight measurement and PRIOR WT Fig 8 308 PRIOR WT gram AVERAGE
11. ales com product support technical support product warranty registration For User Instructions updates and revisions please go to www homscales com CAUTIONS AND WARNINGS _ _ _ INTENDED USE This Health o meter Professional neonatal pediatric scale is intended to be used in a professional medical environment by trained medical staff This product was designed to weigh pediatric patients who are safely positioned on the scale tray Do not modify the product or use it for anything other than its intended purpose To prevent patient caregiver injury or damage to your scale please follow the instructions in this user manual very carefully Do not exceed the weight capacity specified for this scale For accurate weighing this scale must be placed on a flat stable surface For accurate weighing verify before each use the proper operation according to the procedure described in this manual e Do not use in the presence of flammable or explosive materials e If the scale becomes damaged it should not be operated until properly serviced e Do not transport the scale with a patient or object on the scale e Ensure that the scale does not come in contact with liquids excessive temperature or excessive humidity e Do not gas sterilize or autoclave the scale e Scales contain delicate sensors Do not bang into doors walls etc as damage may result Patient Safety This scale is designed for static weighing of patients only No sca
12. ams 2 541 kg Factory setting is grams To change any or all of these settings 1 Press ON ZERO button and wait for the scale to display 0 0 2 Hold MENU button down and press RECALL button Set 0 will be displayed and the 0 will be flashing 3 Press the button repeatedly until Set 5 appears Press the ENTER button 11011 will display Each setting corresponds to a digit within 11011 Use the amp and Y buttons to input your desired setting Press ENTER when your selection is complete Press ENTER to advance to the next digit setting If no other settings need to be changed press ENTER until the scale returns to zero Note The third and fourth digit positions are not currently used Press ENTER to advance to the fifth digit TONE ON OFF Tone on off setting is changed with the first digit When entering the settings menu 11011 will display with the left most 1 flashing To keep the tone sounds on select 1 To turn the tone sounds off select 0 Example Sound on 11011 Sound off 01011 UNIT LOCK Unit Lock is changed with the second digit To enable or disable the LB GM button 1 unlocked 0 locked Example Unlock 11011 Locked 10111 UNIT DISPLAY The unit display is changed with the fifth right most position This controls whether the display weighs in lb grams or Ib kilograms 1 Ib gram O Ib kg Example LB KG display 11010
13. baby first before recording the weight This value can be recalled even after the scale has turned off When the baby s weight is locked PRIOR WT is displayed Fig 5 The weight will remain displayed even after the baby is removed from the tray No further weighings can take place until the weight is cleared by pressing ON ZERO or REWEIGH RECALL Fig 6 _ 008 Figure 5 Weightlock display y REWEIGH RECALL Figure 6 Reweigh Recall button 10 OPERATING INSTRUCTIONS CONT 4 Using the Reweigh Function The Reweigh function is used to reweigh the baby while he or she is still on the tray To reweigh the baby should remain on the tray and a weight measurement should be on the display Simply press REWEIGH RECALL Using the Recall Function The Recall function is used to recall the last weight measurement after the scale has shut down or the display was cleared The scale automatically stores the last weight measurement This value is stored until a new measurement is taken or it is intentionally cleared by pressing ON ZERO To recall a weight value after the baby s weight has been measured the baby has been removed from the tray and the display is off press ON ZERO and then REWEIGH RECALL The stored value will now display To clear the recalled weight and unlock the scale for more weighing either press RECALL or ON ZERO Programming Auto Off Time The 2210KL 2210KL4 has been pre set at the f
14. ight of the baby will be minimal based on the severity of the motion during the weight reading 6 Auto Off As a battery saving feature the scale will automatically turn off when not being used The length of the Auto Off timeout is programmable by the user The factory setting is one minute OPERATING INSTRUCTIONS CONT Using the Tare Function When using this scale the weight of an object such as a blanket on the scale with the baby being weighed can be subtracted from the total weight to determine the net weight of the baby alone The Tare function automatically performs this subtraction avoiding the need for manual calculations TARE Figure 3 Tare button _ 1108 Figure 4 Net weight display 1 Turn the scale on and wait for the display to read 0 2 Place the object i e blanket on the tray The weight of the object will be displayed 3 Press the TARE button NET WT and 0 0 will be displayed If the object is removed from the platform its weight will be displayed as a negative value 4 Place the baby on the tray with the object The readout will now display the baby s net weight 5 Press ON ZERO to return the scale back to normal weighing operation Using the Weightlock Function When using this scale the weight of any object over 512 grams will be locked on the display even after the baby has been removed from the tray This allows the caregiver to tend to the needs of the
15. le should be used for patient transfer To prevent patient injury the patient must be attended throughout the entire weighing event When operating the scale with batteries If the display indicates low battery replace the batteries as soon as possible When replacing inserting batteries be sure to use all new batteries In no event shall Pelstar LLC be liable for damages or injuries whatsoever arising out of or connected with the assembly use or misuse of its products SPECIFICATIONS FORTHISSCALE General Health o meter Professional scales use the most sophisticated microprocessor technology available Each precision instrument is designed to provide accurate reliable and repeatable weight measurements as well as other features that make the weighing process simple fast and convenient In order to achieve satisfactory results the operator must read this manual thoroughly before using this scale If any questions arise regarding this scale or its use please contact Health o meter Professional Scales Customer Service at 1 800 815 6615 2210KL 2210KL4 Scale Specifications Capacity and Resolution 20000 grams 20 kg 45 Ib Resolution O 11300 g 0 25 Ib 0 10 kg 1g 0 1 oz gt 11300 g gt 25 Ib gt 10 kg 5 g 0 1 02 Power Requirements 6 C Cell Alkaline batteries Environmental Operating temperatures 68 F to 85 F 20 C to 30 C Storage temperatures 14 F to
16. n the platform Calibration Error Code Err 4 Scale is below minimum calibration weight Use at least 1000 grams to calibrate the scale 14 TROUBLESHOOTING q Troubleshooting Before contacting service personnel refer to the following instructions to check and to correct any failures If you have further questions call Health o meter Professional Scales Customer Service at 1 800 815 6615 Symptom Possible Cause Corrective Action Scale does not turn on 1 Batteries are not inserted 1 Check that batteries are correctly seated properly in battery tray See assembly section on page 7 to access the batteries and check their positioning 2 Check that all new and fresh batteries are properly inserted into the battery tray 2 Batteries are not fully charged Incorrect weight readings 1 Tray is touching a wallor 1 To test remove all objects other object from tray Turn scale on Display should read 0 Gently push down on the tray with your finger and release The display should show some weight value and then quickly return to 0 2 Ensure the tray is locked completely onto the four 2 Tray is not level locking pins Weight reading consistently 1 Scale is out of calibration 1 See Calibration section on too high or too low 2 Possible broken wire in page 14 to recalibrate the the connector scale 2 Contact Health o meter Professional Scales Customer Service
17. nt 9500 W 55 St McCook IL 60525 Extended Warranty Available This scale is eligible for Health o meter Professional ScaleSurance Extended Warranty Program ScaleSurance extends the warranty period for an additional two years This extension to the standard Limited Warranty can be purchased with new scales or for a facility s existing scale before its current warranty has expired To learn more visit www homscales com scalesurance or contact your medical supply distributor PELSTAR LLC 9500 W 55th St e McCook IL 60525 USA 1 800 638 3722 or 1 708 377 0600 PLEASE REGISTER YOUR SCALE FOR WARRANTY COVERAGE AT www homscales com Health o meter is a registered trademark of Sunbeam Products Inc used under license Health o meter Professional products are manufactured designed and owned by Pelstar LLC We reserve the right to improve enhance or modify Health o meter Professional product features or specifications without notice Pelstar LLC 2017 1 013485 2003 P N UM2210KL 2210KL4 Rev20171218 CERTIFIED 17
18. red only for the original warranty period Who is Covered The original purchaser of the product must have proof of purchase to receive warranty service Please save your invoice or receipt Pelstar dealers or retail stores selling Pelstar products do not have the right to alter or modify or in any way change the terms and conditions of this warranty What is Excluded Your warranty does not cover normal wear of parts or damage resulting from any of the following negligent use or misuse of the product use on improper voltage or current use contrary to the operating instructions abuse including tampering damage in transit or unauthorized repair or alternations Further the warranty does not cover natural disasters such as fire flood hurricanes and tornadoes This warranty gives you specific legal rights and you may also have other rights that vary from country to country state to state province to province or jurisdiction to jurisdiction To get Warranty Service make sure you keep your sales receipt or document showing proof of purchase Call 1 800 638 3722 or 1 708 377 0600 to receive a return authorization RA number which must be included on the return label Attach your proof of purchase to your defective product along with your name address daytime telephone number and description of the problem Carefully package the product and send with shipping and insurance prepaid to Pelstar LLC Attention R A Return Departme
19. utton down and press RECALL button Release both buttons Set 0 will be displayed and the 0 will be flashing 4 Press the button repeatedly until Set 2 appears Press the ENTER button 5 Use the Qand W keys to input 125 as the calibration security code Press ENTER to advance to the next digit After entering the third digit press ENTER and the scale will return to normal weighing mode The security code needs to be entered only once unless the scale is powered off Access to calibration is denied if the proper code is not entered 6 With the known weight on the scale press REWEIGH Quickly before WeightLock activates hold the MENU button down and press RECALL button Release both buttons Set 0 will be displayed and the 0 will be flashing 7 Press the button repeatedly until Set 6 appears Press the ENTER button 8 A weight value will display representing the current calculation of the known weight The hundreds of pounds digit will be flashing Use the A and V keys to input the proper value Press ENTER to advance to the next digit After entering the tenths of pounds digit press ENTER and CAL will display while the scale calibrates itself 9 The readout will then quickly show the old weight then re weigh to show the new calibration weight 10 Remove weight and press the ON ZERO button Wait for 0 0 to display and verify calibration by placing the same known weight back o