3600 SERIES USER MANUAL 3600 Series

image

Contents

1. ST A PROGRAMMABLE DC POWER SUPPLY ba 4 3600 SERIES user s manual y h p l _ ieee VERSION 2 1 2006 03 La 3600 SERIES USER MANUAL SAFETY GUIDE This manual contains the precautions necessary to ensure your personal safety as well as for protection for the products and the connected equipment These precautions are highlighted with a triangle WARNING symbol in this manual and are marked according to the danger levels as follows Danger A It indicates that if appropriate precautions are not taken serious incidents of personal injuries and deaths or significant damages or losses to the properties will be caused Caution A It indicates that if appropriate precautions are not taken injuries or losses of properties will take place Note A Remind you to pay particular attention to the important information related to the products disposal of products or the specific part of documents Warning A Only qualified personnel are allowed to debug and operate this equipment The qualified personnel are specified as those personnel who carry out commissioning grounding and apply the volume identification to the circuits equipment and systems according to the available safety practices and standards Note A Only when this product is transported stored assembled and installed in a proper way and operated and maintained according to the recommendations can it implement the function
2. TE oR oR Step 3 Press the OK button the original set value will be displayed on the LCD It will return to step 2 if your password is wrong Set Curr 1 00A New Step 4 Enter the new current value with the number keypad or rotate the dial to adjust the value Set Curr 1 00A New 1 50 Step 5 Press V A or mV mA button for confirmation Set Curr 1 50A New 1 50A Step 6 Press ESC to go back to the main menu You can exit the current set operation at any point by pressing the ESC key 2 2 3 Output On Off Press the Out on off button to enable disable the power output This key toggles between two states when the output is off pressing this button will turn the output on and vice versa 2 2 4 Store parameters 3600 series power supply can store up to 10 sets of parameters in its nonvolatile memory for later recall These parameters include 1 output voltage 2 current limit 3 maximum output voltage 4 maximum output power 5 keypad locked unlocked 6 Baud rate 7 Communication address The store operation is as follows 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIES USER MANUAL Procedure Operation details LCD display Step1 Press Store button Input Password Enter the password if the keyboard isn t locked please go to Input Password Step 2 step4 ek ak Press OK butt
3. A the current setting key Unit A mV the voltage setting key Unit mV mA the current setting key Unit mA Vmax show the max voltage value Amax show the max current value Enter the confirmation key To set a Voltage Press the V set or mV set button enter the voltage value and then press the ENTER button To set a Current Press the A set or mA set button enter the current value and then press the ENTER button 20 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIES USER MANUAL 4 7 The Voltage Amp Power Meter The Voltage Amp Power Meter show the setting and read back value of voltage current and power g 12162 READ i gt Readback Value SET gt Set Value READ READ Fig 4 10 The Voltage Amp Power Meter 4 8 Dynamic Curve These curve show the dynamic states of voltage and current Voltage Curve Current Curve 10 20 30 40 50 60 70 80 90 100 10 20 30 40 50 60 70 80 90 100 Fig 4 11 The Voltage Curve Fig 4 12 The Current Curve You may drag your mouse on the curve to zoom in out 4 9 Start Communication Click the 2 button to start the communication with the power supply 3600 Series Programmable DC Power Supply 21 VERSION 2 10 2006 03 3600 SERIES USER MANUAL 4 10 Stop Communication Click the Hl button to stop the communication with the power supply 4 11 Setting 4 11 1 Se
4. To search set the query condition and then click the Search button Click the Report button to watch the report To print this report click the Print button To delete historic data click the Delete button Quit quit to the main window 3600 Series Programmable DC Power Supply 25 VERSION 2 10 2006 03 3600 SERIES USER MANUAL 4 14 The State Bar Power gg Add 2 W72 8 15 W 108 0 Sending Powers WER 3 2 2006 09 21 01 28 41 PM Power the power name Add the power address V the max output voltage A the max output current W the max output power Sending Receiving the communication state 4 15 Quit the Software Click the J button to quit the software 4 16 Use the PowerMS software control your power Start the PowerMS program from the Power List select the power supply you want to use If the desired power does not appear on the List use Power Setting to add it Click the Tr button ensure that the Com port baud rate and address is the same as that of the power Click the gt button to start communication Using the Control Mode switch set the power in PC control mode You may now control the power from the computer In the event of communications failure please check the Com port baud rate and Address settings Also ensure that the communication cable is firmly and correctly connected 26 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIE
5. 18V 10mV 4 36V 10mV 4 72V 10mV resolution Current 1mA 1mA 1mA 0 19 999V 10mV 0 19 999V 10mV Readback Voltage 10mV 20 36V 100mV 20 72 V 100mV resolution Current 10mA 10mA 10mA Protection Over voltage Over current Over power AC Input 110 220V AC switch able 60 50HZ Operation environment 0 50 C 80 RH 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIES USER MANUAL Weight 6 00kg Dimensions 212 6mm W x 88 1mm H x 250mm D Free application software PowerMS ActiveX control and DLL tool support VB Software VC DELPHI LABVIEW 3311 isolated TTL to RS232 adaptor 3312 isolated TTL to USB adaptor Optional Parts 3313 isolated RS232 to RS485 adaptor 3314 isolated TTL to RS485 adaptor Mounting rack 0 to 35 C for full rated output At higher temperatures the output current is derated 3 per C 1 3 Features 1 LCD display with backlight 2 High resolution measurement 3 CC CV mode 4 Number keypad and rotary knob 5 Multifunction menu 6 Over voltage over current protection 7 10 parameters storage 8 Compact and light weight 9 Can be used in parallel connection 10 Can be controlled by PC 2 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIES USER MANUAL 1 4 Dimensions and Structure 1 4 1 Dimensions Fig 1 1 Dimensions of 3600 Series Programmable DC Power Supply 1 4 2 Structu
6. ENS PE RAAE EA E E E EE Hiei ne R 22 2 setting es CUM a Machine e A a a en a a cme aa aaa a oaia 2 2 3 Output On Off noreo ed e aia EEE O EEA A T a a e taau aN 22 4 Store parameters Medics e A A E ETE ETE EE A TEA E EAEE ET 2 2 3 R Call paranicters err ae A ER TE vad hE at eran oe E A ta aes 2 3 MENO OP A A do 10 2 3 1 Setting the maximum output voltages s Aen a Peden decile ies evade dan caba daba abad Ao e roda datada 10 2 3 2 Setting the Maximum POWER A o 11 2 3 3 Enabl e disable the TAN A A a eg a ae ee 11 23 4 Setting imitial OUtpul State sic sae o id dada 11 2 3 5 Save Voltage Setting rta print O E E E A E A de cderebteaatedes 11 2 3 6 Setting Baud Ratio 11 2 3 7 Setting communication Address O 31 ccecc cence cence eee een e een e denen een ene een ene ed ene need EE EEE eden EEE ease EGGEE EE EE eH EEE ES 12 ER AO Sees AE A als ETA EAA E AAA EES EE EEA tees 12 230 Clearisayed data ass io a Bie a a a s T ENET SR 12 ZILO Load Default o mae TEE E E ll ios 12 2 Sell D UTEE E E A S T T A A E E E E E E 12 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIES USER MANUAL Chapter 3 Installation of the PowerMS Software cscssscscscsccccccccscscscscssscseesscscssessssssssessesseceesseseessesssseeaees 13 3 Connect the Power Supply 10 Plinio ad asa ti sees ee es Ge ee A ee sea ate a gee ee ee ie 13 3 2 Software Installation iia A de a 13 Chapter 4 Introductions sssi eniinn n nen a asiccedede
7. S USER MANUAL Chapter 5 Uninstall PowerMS Software 5 1 Uninstall the PowerMS Software From the Start Menu select Program gt Array gt PowerMS gt Uninstall PowerMS to unstall the software Remember to quit the program before uninstalling 3600 Series Programmable DC Power Supply 27 VERSION 2 10 2006 03
8. alog box displays press NEXT to continue Fig 3 3 The Welcome dialog box 3 2 3 The License Agreement dialog box displays Click Yes to accept the License Agreement and proceed with the installation process Note If you do not want to accept the License Agreement click No to abort the installation process Fig 3 4 The License Agreement dialog box 3 2 4 The User Information dialog box displays enter your name and your company s name then click Next Fig 3 5 The User Information dialog box 14 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIES USER MANUAL 3 2 5 The destination folder dialog box displays The default folder is C Program Files Array PowerMS You may click Browse to select other installation path Fig 3 6 The destination folder dialog box 3 2 6 The installation option dialog box displays Select Typical to install all components or select Custom to select installation components Fig 3 7 The Installation option dialog box 3 2 7 The Select Program Folder dialog box displays Specify a program folder or leave the default folder then click Next Fig 3 8 The Select Program Folder dialog box 3600 Series Programmable DC Power Supply 15 VERSION 2 10 2006 03 3600 SERIES USER MANUAL 3 2 8 Copy the files to your hard disk Fig 3 9 Copy Files Software installation is complete when finishe
9. aud Rate This function is used to set the communication baud rate When you select Baud Rate Set function the LCD will display 3600 Series Programmable DC Power Supply 11 VERSION 2 10 2006 03 3600 SERIES USER MANUAL BaudRate 4800 BaudRate 9600 Select the Baud Rate by using the UP and DOWN keys or the rotary BaudRate 19200 knob then press Enter for confirmation BaudRate 38400 2 3 7 Setting communication address 0 31 This function is used to set the address of the power To communicate with the computer or other equipment the 3600 power supply must be assigned an address When you select Address Set function the LCD will display Address Set Set the address by using the number keyboard or the rotary knob and then press Enter for confirmation The valid address range is from 0 to PENS 31 2 3 8 Key Lock This function is used to lock the keyboard to keep the 3600 from unauthorized operation Only the person with the correct password is allowed to operate the power supply Select the Key Lock function the LCD will display Enter Password Enter a 4 numbers password then press Enter to confirm 2 3 9 Clear saved data This function is to clear the parameters stored in the 3600 s nonvolatile memory When you select Clear Save Data function the LCD will display Clear Enter the memory address you want to clear then press
10. choose the power you want to use from the power supply list 3645 Fig 4 5 The Power Supply List 4 3 The Control List To set who controls the power supply the PC or the power itself or to enable disable the power output select the corresponding instruction from the control list Control Power Self Fig 4 6 Select the Control Instruction 4 4 The Control Switch The On Off switch is to turn on off the output the Self PC Control switch is to set who control the power supply the PC or the power itself e j Fig 4 7 The Control Switch 4 5 The Tool Buttons On the top left of the main window there are 6 tool buttons E Start Start communication Stop Stop communication Setting setting COM Port and recording interval Power Setting Setting power supply parameters Report Data report la dla ja Quit Quit the PowerMS program 3600 Series Programmable DC Power Supply 19 VERSION 2 10 2006 03 3600 SERIES USER MANUAL 4 6 Keypad and Rotary dial A V SET Z S 0 0 MUA 5 0 A SET Fig 4 8 Voltage and Current setting dial To quickly modify a parameter Voltage or Current put the mouse on the red point of the dial and rotate To accurately set a parameter use the keypad Fig 4 9 Keypad Number Keys 0 9 the point key C the cleared key j the backspace key V the voltage setting key Unit V
11. d 16 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIES USER MANUAL Chapter 4 Introduction 4 1 Running the program 4 1 1 To run the PowerMS program select Start gt Program gt Array gt PowerMS and click PowerMS to run the program Fig 4 1 Start the program 4 1 2 The PowerMS startup pattern Programmable Power Supply gt ARRAY ELEUTACES IE CELTI Fig 4 2 The PowerMS startup pattern 3600 Series Programmable DC Power Supply 17 VERSION 2 10 2006 03 3600 SERIES USER MANUAL 4 1 3 The PowerMS Main Window nal rire Lau bu mnn pnn biali t ia bad ran ann LAA i Y ny AAA Mestad Ball Neal Hal Bad AA FAA y lu Malas Cure Caneel Carer Fig 4 3 The PowerMS Main Window 4 1 4 Once the PowerMS software is started the o icon is shown on the state bar Right click this icon the following menu will be displayed Shaw Hide Start Communicate Stop Eommunicate About Quit Fig 4 4 Show Show the interface Hide Hide the interface Start Communicate Start the communication Stop Communicate Stop the communication About About PowerMS Quit Quit the software 18 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIES USER MANUAL 4 2 The Power Supply List The power supply list lists all registered power on the computer To make the PowerMS control your power
12. e amp The up moving key The down moving key V A Set the voltage as V Set the current as A mV mA Set the voltage as mV Set the current as mA Left Operation The left moving key Right Operation The right moving key ESC Escape key OK Confirmation key Rotary knob The rotary dial 4 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIES USER MANUAL 1 4 2 2 Back view Communication interface I 5 Go Wire rock ie aes ie 3 Ag oe H m Power suppl Fan Wrap O ll mi lu pply plug r TT E E A im E J Fuse j AC line voltage switch Fig 1 6 Back view The fuse can be changed easily by using a small flat screw driver Replaced with a T3 15A fuse 3600 Series Programmable DC Power Supply 5 VERSION 2 10 2006 03 3600 SERIES USER MANUAL Chapter 2 Operation 2 1 Connect the Power Supply to the load Fig 2 1 Connect the Power Supply to the load 2 2 Main functions 1 Setting the output voltage 2 Setting the current limit 3 Output On Off 4 Store parameters 5 Recall parameters 2 2 1 Setting the output voltage 3600 series power supply provides two methods to set the output voltage by the number keypad and by the rotary knob Please see the following operation procedure 6 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIES USER MANUAL Procedure Operation details LCD disp
13. l display Sw Enable Def Use the UP and DOWN keys or the rotary knob to select and press Enter to confirm Sw Disable 2 3 4 Setting initial output state The Initial Out Set function is used to set the output state conditions when switching on the 3600 Power Supply the next time it is used Select Ini Out Save to save the current output state before switching off If the current output is on next time the 3600 is switched on the output will be in the ON mode If the current output is off the next time the 3600 is switched on the output will be in the OFF mode Selecting Ini Clear Def will ensure that the output is in the OFF mode each time the 3600 Power Supply is switched on Ini Out Save Use the UP and DOWN keys or the rotary knob to select and press Enter to confirm Ini Clear Def 2 3 5 Save voltage setting The Volt Save Set function is to set whether to save the voltage setting Select Save Out Volt the set voltage value will be saved in nonvolatile memory and couldn t be lost even if the 3600 is switched off When switching on the next time the voltage value will be automatically reloaded Select Don t Save Def the default value OV will be loaded every time switching on Save Out Volt Use the UP and DOWN keys or the rotary knob to select and press Don t Save Def Enter to confirm 2 3 6 Setting B
14. lay Step 1 Press V set Input Password Secs Enter the password if the keyboard isn t locked please go to Input Password tep step4 dolo TR Press the OK button the original set value will be displayed Set Volt 0 000V tep on the LCD It will return to step 2 if your password is wrong New Soa Enter the new voltage value with the number keypad or rotate Set Volt 0 000V tep the dial to adjust the value New 10V Set Volt 10 00V Step 5 Press V A or mV mA button to confirm New 10 00V Step 6 Press ESC to go back to the main menu You can exit the voltage set operation at any point by pressing the ESC key For example set the output voltage to 24 3V 1 Setting by number keyboard Step1 Press V set button Step2 Enter the password by using the number keypad if the keypad isn t locked please go to step 4 Step3 Press OK button if the password is wrong please go to step2 for reentering Step4 Press 2 4 and 3 button to enter the voltage value Step5 Press V A button 2 Setting by Rotary knob 1 If the keypad isn t locked directly rotate the Rotary knob and the voltage will be continually changed from the previews value according to the rotation At the beginning the cursor will be shown on the last number of the value which is indicated on the LCD you can move the cursor to each number by using ana buttons and then rotate to change
15. n with the power cable removed To avoid injuries always disconnect power discharge circuits and remove external voltage sources before touching components 6 Do Not Substitute Parts or Modify Instrument Because of the danger of introducing additional hazards do not install substitute parts or perform any unauthorized modification to the instrument Return the instrument to a qualified dealer for service and repair to ensure that safety features are maintained II Connecting the power line 1 Inspect the power selection switch on the back panel to assure if the selected voltage is the same as environment power voltage If not please refer to the notice around the power plug 2 Before connecting the power supply please be sure that the switch on the front panel should be in the off position 3 Connect the power cable to the AC in the power supply and the 3 connector plug Please be sure that the AC power supply is grounded 4 Press the switch on the front panel to switch on the instrument and you can start to use it 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIES USER MANUAL III Fuse 1 The fuse is at the position of power input part on the back panel for the purpose of avoiding failure brought by using wrong voltage Please pay attention to the following items when you change the voltage input and the fuse 2 Before changing the voltage and fuse please be sure that the AC power is
16. on It will return to step 2 if your password is Step 3 SAVE 1 wrong Enter the memory address 1 to 10 using the number key or Step 4 SAVE rotate the rotary knob to change the address Press the Enter button for confirmation It will return to Step Step 5 4 if the address is out of the range You can exit the Store operation at any point by pressing the ESC key 2 2 5 Recall parameters To recall the parameters previous stored in the 3600 please follow this operation procedure Procedure Operation details LCD display Step1 Press Recall button Input Password Enter the password if the keyboard isn t locked please Input Password Step 2 go to step4 Ao Press OK button It will return to step 2 if your Step 3 y Recall password is wrong Ie Enter the memory address 1 to 10 using the number Step 4 Recall key or rotate the rotary knob to change the address Press the Enter button for confirmation It will return Step 5 to Step 4 if the address is out of the range You can exit the recall operation at any point by pressing the ESC key 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIES USER MANUAL 10 2 3 Menu operation The Menu operation offers some setting and adjusting functions The operation and functions are as following Procedure Operation detail
17. re 1 4 2 1 Front view Front panel is for users to operate and there is one LCD display one number keypad and one rotary knob Please see the following pictures Fig 1 2 Front view of 3600 Series DC Power Supply 1 LCD display The 1st line Left The voltage value When output is off this value is 0 0004 O 0008 the set value when output is on this is the actual output T m 0 00 OFT voltage value Right The actual output current value Fig 1 3 LCD Display of 3600 Series power supply The 2nd line Left The output power value Flashing power value means the over power Middle ON OFF the output state of the power supply Right PC represents the Power Supply is controlled by the computer 3600 Series Programmable DC Power Supply 3 VERSION 2 10 2006 03 3600 SERIES USER MANUAL 2 Arrangement of the Keyboard In general the keyboard will perform the function of the black words 1st But in the 2nd mode it will perform the function of the words in blue PUKE f mm ACT aa alofajo a de Jape Fig 1 4 Keyboard of 3600 Series DC power supply 3 Rotary knob and function keys ADJUST Fig 1 5 Rotary knob and function keys 0 9 The number keys Store Store the current setting value Recall Recall the saved setting value Menu The menu operation Out on off Enable disable the output Enter The confirmation key V set Setting voltage value I set Setting current valu
18. s LCD display Step1 Press Menu button Input Password aad Enter the password if the keyboard isn t locked Input Password tep please go to step4 ok Press the OK button It will return to step 2 if your Max Voltage Set Step 3 password is wrong Max Power Set Max Voltage Set Max Power Set Rotary Knob Set Initial Out Set Volt Save Set The LCD displays the menu functions Use the UP and Step 4 Baud Rate Set DOWN keys to select a function Address Set Key Lock Clear Save Date Load Default Exit Step 5 Press Enter for confirmation You can exit the Menu operation at any point by pressing the ESC key 2 3 1 Setting the maximum output voltage When you select the Max Voltage Set function the LCD will display Max Volt 24 00 V New V Set the maximum output voltage by using the number keyboard or the rotary knob then press Enter for confirmation 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIES USER MANUAL 2 3 2 Setting the maximum power When you select the Max Power Set function the LCD will display Max Power 108 00W Set the maximum output power by using the number keyboard or the rotary knob then press Enter for confirmation New _W 2 3 3 Enable disable the rotary knob The Rotary Knob Set function is to enable or disable the rotary knob When you select the Rotary Knob Set function the LCD wil
19. s properly and reliably 3600 Series Programmable DC Power Supply 1 VERSION 2 10 2006 03 3600 SERIES USER MANUAL 11 The following general safety precautions must be observed during all phases of operation service and repair of this instrument Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design manufacture and intended use of the instrument The manufacturer assumes no liability for the customer s failure to comply with these requirements A Attention I Safety 1 Users should operate according to this manual 2 There is high voltage inside the instrument please avoid touching it directly 3 Please read the user manual carefully before you use the instrument to assure your safety 4 Ground the Instrument This product is provided with a protective earth terminal To minimize shock hazard the instrument chassis and cabinet must be connected to an electrical ground The instrument must be connected to the AC power supply mains through a three conductor power cable with the third wire firmly connected to an electrical ground safety ground at the power outlet 5 Keep Away From Live Circuits Operating personnel must not remove instrument covers Component replacement and internal adjustments must be made by qualified service person Do not split the components when power cable connected Under certain conditions dangerous voltages may exist eve
20. steUeiesecedescesdiseenessddneiecesdsescasdssseceeeess 17 Al Running the program arrear aa ea ea A oa fas EN REE A E E A A N ea 17 4 2 The Power Supply Li di idad 19 4 3 The Control Listerne freret tietoo tta p E E A E EOE AETS ETE AEAEE ig vend EE EAA EETA 19 4A The Control Switch idas ti a o lat 19 4 5 The Fool Buttons cai A A stg AAA A A AA cutie AAA 19 4 6 Keypad ad os ds a nd te dos 20 4 7 The Voltage Amp Power Meter moo sci fee cee cea nda ube beg ia TAIANA ao co 21 4 8 Dynamic Civ ci 21 4 9 Start Communication oai a a E dae Hie Saree ae each ae ns cere Seated hee ede ame aa eas 21 4 10 Stop Communication diaria 22 NO 22 4 12 A ase sole tk ao pte ache ene te dake Caled obo th oe dodo leu tage aa e goa dew a cudedeleets a dacs a oak eget 23 413 Data Report unit drid ds west cnc aie o ev os ately a AA dd on AA A A ad da 25 Aids The State Dart td ia da dto AEEA nan O EEAS 26 4 15 Quit the SOM Ware ei is As ida te Sued be ia 26 4 16 Use the PowerMS software control your POWET oooooococncncncncncnnonono nono non r none n ease rr rn rr nn nn eeeeeeeeeeeeeenen es 26 Chapter 5 Uninstall PowerMS Software cccscscccscccsccsccccccccccscescsscccsssccsssccsssceesssesescesesceeseeeess 27 5 1 Uninstall the PowerMS Software ticos eta pi tito deans 27 vi 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIES USER MANUAL Chapter 1 General Introduction 1 1 General Introduction The ARRAY 3600 Series Po
21. switching off and be sure that there is no other equipment connected to this instrument 3 Put a screwdriver into the fuse mounting press it and the fuse mounting will pop up 4 Pull out the fuse change it according to the label beside the power input plug Warning To avoid damaging the instrument please be sure to change a suitable type fuse 3600 Series Programmable DC Power Supply 111 VERSION 2 10 2006 03 3600 SERIES USER MANUAL iv 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIES USER MANUAL Programmable DC Power Supply 3600 SERIES Table of Contents Chapter 1 General IntroductioN oooococooncocncncncnoncnonononoronocorororornonrnononononononorononoronocarrorarnrorncnrrnoncnconarucnnnos LL General Introd ucton ii Pag saa sie che tes estate ae ata va eis ad eh tea eg Patel cha A a a ee i Reese a ea a Wace ii IDA SPeciliCaOnse ts AA tect e a E a E A AS 13 Features A A a dia 1 4 Dimensions and Ud hs TAT Dime ON T AIETE a E a A EEEE E E E E E E EA E EN A A adas 142A Front VIEW 2304025 dr tend ators naw AE E EE EE ENE ONEEN E E E O a a aaia 142 2 Back Vi Wi duce Ea EA EE EEEE OSEE ias adn cda Chapter 2 Operation secre aeea rnEeE E EEREN E ENADE A EE ea EEEE 2 1 Connect the power supply to the loadin es eee riiet Cora ini EEA E NN E eE E E EEEE EEES 22 Main functions aeey a e tones gaa e oleae aces oe A a a RA A oh a A E e oats 2 21 Settings the output volta tenisine ea aE E E
22. the Enter key 2 3 10 Load Default This function is to restore all the parameters to the factory setting Select Load Default function the LCD will display Don t Load Select Load Default and press OK to restore to the factory Load Default setting 2 3 11 Exit Select Exit to exit the menu operation 12 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIES USER MANUAL Chapter 3 Installation of the PowerMS Software 3 1 Connect the Power Supply to PC With the optional communication adapter you can connect the 3600 power supply to your computer through RS 232 USB or RS 485 port Connect the 3600 to a RS 232 port with the 3311 adapter to a USB port with the 3312 to a RS 485 with the 3314 If your computer doesn t have an RS 485 port you may choose the 3313 RS 232 gt RS 485 adapter Fig 3 1Connect the power supply to PC 3 2 Software Installation 3 2 1 Insert the Array software CD into the CD ROM drive double click My Computer gt Array CD gt PowerMS gt Setup exe to start the installation the Fig 3 2 will be displayed Powers 3 2 Setup is preparing the InstallShield A Wizard which will guide you through the rest of the setup process Please walt 99 gt Fig 3 2 The Initialization of the Installation 3600 Series Programmable DC Power Supply 13 VERSION 2 10 2006 03 3600 SERIES USER MANUAL 3 2 2 The Welcome di
23. the number and let it stay at 24 3 V 2 If the keypad is locked Step1 Press V set button Step2 Enter the password by using the number keypad Step3 Press OK button if the password is wrong please go to step2 for reentering Step4 Rotate the Rotary knob to change the value the operation is the same as item 1 Step5 Press V A button to confirm 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIES USER MANUAL 2 2 2 Setting the current limit During actual operation if a load change causes the current limit to be exceeded the power supply will automatically crossover to the constant current mode at the preset current limit and the output voltage will drop proportionately For example when output voltage 10V load R 10 Ohm then the load current should be V R 1 A If the current value is set to 1 50A the power supply works in CV mode the actual current value should be displayed on the LCD as 1 00A If the load resistor drops to 5 Ohm the current will increase When the current exceed 1 5A the power supply will change to CC mode and the output voltage will drop down to7 5V to maintain the actual current value to 1 5A To set the current please follow this operation procedure Procedure Operation details LCD display Step 1 Press I set Input Password Step 2 Enter the password if the keyboard isn t locked please go to step4 Input Password
24. tting Com port and baud rate Click the M button select the correct Com port and baud rate The baud rate setting should be the same as the connected power supply Setting v r x COM Address Other COM Port com v BaudRate 9600 Fig 4 13 Com Setting Window 4 11 2 Setting power supply address COM Address Other Address 1 e Fig 4 14 Address Setting window 22 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIES USER MANUAL 4 11 3 Setting Recording Interval COM Address Other Recording Interval s fo Fig 4 15 Setting Recording Interval window 4 12 Power setting Click the FA button the Power setting window will be displayed A Fig 4 16 The Power Setting window The Power Registration Records show the parameters of all registered power supply To add a new power supply click the idd button 3600 Series Programmable DC Power Supply 23 VERSION 2 10 2006 03 3600 SERIES USER MANUAL all x Power Supply Parameters Power ID Power Hame Poma Power Addrars ls x Max Curent Ay 3 Me Pore Max VoltageiWy 35 w OK fi Cancel Fig 4 17 Add New Power window Enter the Power Name Address and the maximum value of voltage current power then press OK to confirm Note the Power ID is assigned by the software Parameter Explanation Range Power Name Name Of the Power Supply ASCII Max Current The Ma
25. wer Supply is a compact programmable DC power supply It is equipped with backlight LCD display numerical keypad and rotary knob which make it much easier to use It offers constant voltage mode and constant current mode Programming features include over current protection maximum output voltage and output power limitation and 10 parameters storage It is an essential instrument for scientific research education service and so on institutions 1 2 Specifications Mode 3644A 3645A 3646A Number 1 1 1 Voltage 0 18V 0 36V 0 72V DC Current 0 5A 0 3A 0 1 5A Output Power max 90W 108W 108W 0 3 999V 0 01 3mV 0 3 999V 0 01 3mV 0 3 999V 0 01 3mV Line Voltage 4 18V 0 02 10mV 4 36V 0 02 10mV 4 72V 0 02 10mV Regulation Current 0 02 8mA 0 02 8mA 0 02 8mA Load Voltage 0 02 20mV 0 02 10mV 0 02 10mV Regulation Current 0 02 15mA 0 02 10mA 0 02 8mA Ripple Voltage lt 1mVrms lt ImVrms lt 1mVrms and noise Current lt 5mArms lt 4mArms lt 3mArms Programming Voltage 0 1 20mV 0 1 20mV 0 1 20mV accuracy at 25 C4 5 C Current 0 2 20mA 0 2 20mA 0 2 20mA Readback 0 19 999V 0 2 20mV 0 19 999V 0 2 20mV Voltage 0 2 20mV accuracy at 20 36V 0 2 100mV 20 72V 0 2 100mV 25 C4 5 C Current 0 2 20mA 0 2 20mA 0 2 20mA 0 3 999V 1mV 0 3 999V 1mV 0 3 999V ImV Program Voltage 4
26. ximum Output Current 0 5A 0 3A 0 1 5A Max Power The Maximum Output Power 0 90W 0 108W 0 108W Max Voltage The Maximum Output Voltage 0 18V 0 36V 0 72V Power ID The ID of Power Supply To delete a registered power supply select the power from the Power Registration Records then click the Delete button To modify a power s parameters select the power from the Power Registration Records then click the Ke Modify button To query a power supply click the Gi Query button then enter the power name you want to query To show all the registered power supplies click the Show Ap button To print the Power Registration Records click the gi Print button Attention after the Add Modify Delete operation the program must restart so that the modifications may take effect The following dialog box will be shown click Yes to close the program then restart the program from the Start menu 24 3600 Series Programmable DC Power Supply VERSION 2 10 2006 03 3600 SERIES USER MANUAL Er Parsmeters hares been modifed you mush restart the program Fig 4 18 After Add Modify Delete operation the program must restart 4 13 Data Report Click the om button the data report window will be shown CA El ony FP Heme r Curent i j Ta fi El Adder E ad Ta fi M mip i a fi a Pr 3 ap 3 M Toa adadi Tm nos T Dae se a TA Janne EH Fig 4 19 The Data Report window