1. 2 5 3 Installation In Hybrid System With TS 30 For Designated Circuits Configuration C Install the TS 50 on the line side of the main distribution panel as illustrated in Configuration A The TS 30 can be installed between inverter default and a circuit panel supplied by the larger amp alternating power supply dominant Connect the inverter to terminals 7 and 8 and connect the 30 amp branch circuit to 5 and 6 Connect the designated circuit panel to the output terminals The inverter will only supply the load in the absence of the 50 amp power supply in which case only the load designated to the 30 amp branch circuit is supplied The timer delay bypass switch on the TS 30 should be in the ON position Diagram 1 Use copper wire ROT NEU HOTT NEU NEU GP TS 50 75 C marimar GENERATOR SHORE PANEL lid TIGHTEN SCREWS TO 16 INCH POUNDS ed vo ANSI STD vo NEU FROM ONE SoAMP HOT HOT FROM GENERATOR LEG GENERATOR SNO cao elm NEU FROM HoT FROM POWER CORD TWO 30AMP HOT ere NEU FROM LEGS 240VAC 22222224 PANEL Ground WARNING NOTE ALL SOURCES MUST BE SECURED OFF 120240 VOLT TRANSFER RELAYS MAY NOT BEFORE SERVICING REFER SERVICE TOA OPERATE IF POWER IS LOST ON ONE HOT QUALIFIED ELECTRICIAN LEG WHEN RUNNING ON 240 VOLTS 50 AMP SYSTEM MAIN GENERATOR
2. GENERATOR ich Transfer Switch 50 240 VOLT 50 AMP SYSTEM POWERCORD GENERATOR MAN we PLEI Branch Circuits MAIN PLL LL L Branch Croats H Transter 50A 240W SWITCH Swich POWERCORD GENERATOR 30A 120W SWITCH 240 VOLT INVERTER Switching designated circuits in sub panel 50 AMP SYSTEM HYBRID SYSTEM 2220 Ground 222 When protected by a molded case breaker rated 30 amps or ess this inel generator switch is rated for use on a circuit capable of delivering not more than 5000 symmetrical amperes GP TS 50 3 Operational Testing READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1 Plug in the powercord If the main panel circuit breakers are switched on RV load should operate normally Unplug the powercord 2 Start the generator There is a pre programmed 20 30 second delay in the transfer switch The delay is designed to allow the generator a brief warm up period When the delay completes its cycle the switch should engage and the RV load should operate normally An audible click should sound as the switch engages 3 Shut down the generator As the generator winds down the switch should disengage without chatter or cycling An audible click should sound as the switch disengages 4 Plug in the powercord Start the generator After the preprogrammed delay the switch should transfer power automatically from the pow
3. conductors and the ground in the entire 120 240 VAC circuitry beyond the transfer switch In most cases it will also test the powercord itself Turn off the hi pot 7 Do not test the transfer switch generator input The hi pot will damage the time delay control module in the transfer switch If the generator wires to the switch must be checked disconnect the generator wires from the transfer switch and connect hi pot test leads to the loose wires Reconnect wires after testing 8 If hi pot test fails there is a short in the system The next step is to isolate the location of the short Turn off the main breaker in panel and hi pot test again If the test still fails the fault is between the switch and the panel Test cord for shorted plug If the test passes turn on the main breaker and turn on all branch breakers except one Retest each branch circuit individually until the shorted circuit is isolated Repair the fault and retest The hi pot test is successful when there are no more fault indications 6 Generator Note GP TS 50 It is never advisable to start or stop a generator under load To prolong the life of this transfer switch and the life of the air conditioner microwave oven and other appliances always turn those appliances off before starting or stopping the generator 7 Medical Appliances Go Power will not knowingly sell a Go Power Automatic Transfer Switch for any life support application It is strongly rec
4. Transfer Switch GP TS 50 powered by carmanah Owner s Manual carmanah WARNING MULTIPLE 120 240 VOLT POWER MODEL MODELE MODELO TS 50 SOURCE ALL SOURCES MUST BE SECURED OFF CONFORMS TO UL STD 1008 BEFORE SERVICING FOR YOUR SAFETY REFER I CERTIFIED TO CSA STD C22 2 QUALIFIED ELECTRICIAN e us NO 1781 3033090 ATTENTION CONTIENT PLUSIEURS SOURCES DE 120 240 VOLTS TOUTES LES SOURCES DOIVENT CONFORME LANORME UL 1008 TRE TEINTES AVANT L ENTRETIEN POUR VOTRE CERTIFI A LA NORME CSA C222 SECURITE CONSULTER UN ELECTRICIEN QUALIFIE NO 178 1 ADVERTENCIA FUENTE DE VOLTAJE MULTIPLE DE ESTE PRODUCTO CUMPLE CON 120 240 VOLTIOS ASEG RESE QUE TODAS LAS EL EST NDAR UL 1008 Y CON LA FUENTES ESTEN APAGADAS ANTES DE REPARAR CERTIFICACION DE LAASOCIACION DE O HACERLE MANTENIMIENTO ALA UNIDAD PARA ESTANDARES CANADIENSE C222 SU SEGURIDAD CONTRATE A UN ELECTRICISTA NO 178 1 CALIFICADO www gpelectric com 1 866 247 6527 made in China GP TS 50 Table of Contents Introduction Installation Operational Testing Troubleshooting Hi Pot Testing N N Generator Note Medical Appliances 10 Caution 10 Disclaimer of Liability and Warranty 10 1 Introduction Go Power Transfer Switch 50 TS 50 provide automatic power switching between two or three separate 120 240 volt AC input sources including power cords onboard
5. conditions remember that brownouts can be harmful to most appliances A better alternative might be to utilize the generator until park voltage conditions improve 4 3 Localized Low Voltage Low voltage conditions can be caused by specific situations such as an additional cord that is too long and too small for the load Do not attempt to extend the RV powercord by using a 16 gauge 100 foot extension cord or any cord not rated for an RV size load A localized low voltage condition will result when a load is turned on that is larger for what which the cord is designed As soon as the RV tries to draw more current than the amount for which the cord is rated the voltage will fall within the length of the cord and the RV will experience low voltage This is especially noticeable during in rush current situations such as an air conditioner start up Contactor based transfer switches are affected by this The compressor will try to start the voltage will drop which will cause the contactor to drop out at which point the voltage will rise to the pre in rush level The contacts will chatter when the A C compressor kicks in however the voltage may read normal Most meters are not fast enough to record this voltage drop You can test for low voltage readings during this inrush cycle by reading voltage at the contactor terminals while manually holding the contactor plunger down in its closed position This will override the chattering condition and the m
6. ect the powercord neutral to the powercord lug labeled NEUTRAL WHT GP TS 50 2 Connect powercord hot 1 and hot 2 to powercord lugs HOT 1 BLK and HOT 2 RED 3 Connect the generator neutral s to generator lug labeled NEUTRAL WHT 4 Connect generator hot 1 and hot 2 to generator lugs HOT 1 BLK and HOT 2 RED 5 Connect output to panel or other destination to the applicable panel lugs The bypass switch should be in the off position marked 1 2 5 2 Installation Between Inverter and Alternating Source Configuration B For installation between an inverter default and another power supply dominant such as the output from a prior powercord generator transfer switch connect the inverter neutral to powercord lug labeled NEUTRAL WHT and connect the inverter hot to powercord lugs labeled HOT 1 BLK and HOT 2 RED Connect the alternate power supply neutral to generator lug NEUTRAL WHT Connect alternate power supply hot 1 and hot 2 to generator lugs HOT 1 BLK and HOT 2 RED Connect the output to applicable panel lugs These connections will allow any other supply to dominate the inverter and the inverter output will pass through the normally closed contacts of the switch This allows the inverter to operate only in the absence of the other power supplies which is ideal for inverters Set the timer delay bypass switch of the inverter alternate source transfer switch to the ON position
7. ercord to the generator Listen for the audible click as the switch transfers as there will likely be no other indication that the switch has engaged Shut down the generator and unplug the powercord 5 On transfer switch arrangements with three power supplies plug in the powercord start the generator and turn on the inverter With all three supplies energized at the same time the switch will select the generator for the primary supply choice Shut down the generator The switch will transfer to the powercord Unplug the powercord The switch will transfer to the inverter The inverter should always be connected so that it is only selected in the absence of both the other supplies 4 Troubleshooting 4 1 Low Voltage Low voltage is harmful to most appliances Contactor based transfer switches are also affected by low voltage if the voltage level drops far enough the contactor points will chatter Sustained contact chattering can cause transfer switch damage Switches that have been damaged by chattering need to be returned to the factory for replacement GP TS 50 4 2 General Low Voltage Low voltage can be caused by low voltage conditions such as an RV park with inadequate wiring for crowded camper conditions where everyone s electricity suffers brownout In this case a voltmeter will be helpful and will show a low voltage reading from the park receptacle even before the RV is plugged in When you experience general low voltage
8. es not matter which is hot 1 and which is hot 2 H In some applications it may be desirable to feed a 120 volt supply such as an inverter into both hot legs of a transfer switch so that the 120 volt supply can operate the entire RV load Although discretion is advised in designing this into the system it is acceptable as long as the connection to both hot legs is accomplished on the input side of the transfer switch To do this connect the hot from the 120 volt supply such as an inverter to hot 1 and then attach a jumper wire of the same gauge from hot 1 to hot 2 Consideration should be given to the following The entire load must be 120 volt you cannot operate 240 volt load from a 120 volt supply There may be a load which would be undesirable to run from this particular 120 volt supply that load should be isolated when the 120 volt supply is operating The TS 50 is sometimes used as a lock out switch to prevent specific loads from being operated from designated supplies Example preventing a battery charger or air conditioner from running from an inverter yet operating from generator or powercord Tighten cable clamps on switch enclosure J Attach lid The lid is designed to snap on and should not open without deliberate effort 2 5 1 Installation Between Powercord and Generator Configuration A The TS 50 is designed with an easy to wire bridge Refer to Diagram 1 for wiring lug designations 1 Conn
9. eter will have time to register the reduced voltage If this condition exists identify and correct the low voltage situation before proceeding further 4 4 Physical Interference Some transfer switch models have wiring connections made by wire nuts on 63 leads Occasionally on these models the wiring connections will get folded into the cbox in such a manner that the wiring will interfere with the physical operation of the relay Visually inspect for free operation of the relay s 5 Hi Pot Testing MANUFACTURING COMPANIES ONLY GP TS 50 NOTE If the hi pot test is performed from the plug on the powercord the test may only hi pot the cord itself it may not test the RV wiring beyond the switch The hi pot test should be performed from either the transfer switch output or from the main panel Test as follows 1 Turn on all circuit breakers in the panel 2 Make sure the generator is off 3 Make sure the powercord is unplugged Verify that the prongs on the powercord plug are protected so that the hipot voltage won t cause a fault reading from a short or cause bodily injury from electrical shock 4 Turn off or disconnect all appliances that would be damaged by the hi pot test 5 Connect the hi pot leads to a Transfer switch ground bar b Transfer switch output terminals hot 1 hot 2 if present and neutral 6 Energize the hi pot and conduct test This will hi pot test for leakage short between the current carrying
10. generators onboard inverters or all three The ATS will sense the presence of available power supplies and automatically select the proper one The TS 50 can be installed at the electrical entry of the RV on the line side of the main distribution panel or it can be installed on the load side of the panel between the main panel and a sub panel allowing switching for either the entire electrical load or only designated circuits switch ground bar A direct access hole to the ground bar is provided through the enclosure for convenience Determine proper connections of wire conductors to electrical terminals 120 VAC wiring the ground wire is bare or green the neutral wire is white and the hot wire is black On 240 VAC 2 Installation GP TS 50 READ AND FOLLOW ALL SAFETY INSTRUCTIONS 2 1 Disconnect Power Make sure the generator is off the external power cord is unplugged and the inverter if any is shut off 2 2 Mounting Location The TS 50 mounting location may be on any interior surface where the unit will be out of direct weather The chosen location must be accessible after installation is complete to facilitate future servicing If possible mount the TS 50 near the power cord entry or the location of the generator output Typical locations include under counter cabinets below closet compartments inside the bed pedestal or cabinets overhead cabinets under floor storage compartments accessed from the vehicle exterior e
11. ommended that you do not operate any life support equipment from a transfer switch If the switch should malfunction or fail to operate due to other external conditions it is possible that all connected appliances including any life support equipment will also shut down resulting in a risk of medical complications and potential loss of life 8 Caution Do not install this or any electrical accessory in the battery compartment or a compartment intended for storing flammable liquids or liquids that produce flammable or explosive fumes such as gasoline etc There are components in the Transfer Switch that in their normal operation may cause arcing In addition the act of turning on a light switch or unplugging the cord on an electrical appliance can cause a spark which can ignite any combustible liquids or vapors Therefore do not install a transfer switch in a compartment intended for storing flammable liquids and never store flammable liquids inside a compartment containing any electrical device 9 Disclaimer of Liability amp Warranty Visit www gpelectric com for additional product warranty information All Go Power Transfer Switches come with a two year warranty Go Power warranties all Go Power Transfer Switches in the continental United States and Canada from defects in materials or workmanship under normal use for two years from date of retail purchase and will repair or replace any Go Power Transfer Switch unde
12. r warranty found to be defective free of charge This warranty is not valid against defects resulting from but not limited to Misuse and or abuse neglect or accident Exceeding the unit s design limits Improper installation including but not limited to improper environmental protection and improper hook up Acts of God including lightning floods earthquakes fire and high winds 10 GP TS 50 Damage in handling including damage encountered during shipment or installation Outdoor weather 9 1 Repair and Return Information Visit www gpelectric com to read the frequently asked questions section of our website to troubleshoot the problem If trouble persists 1 Call your Go Power Technical Support team 1 866 247 6527 2 Return defective product to place of purchase 11 GP TS 50 powered by carmanah 2011 GO POWER By Carmanah Technologies www gpelectric com MOBI MAN GP TS 50 vA Dec2011 12
13. tc 2 3 Electrical Preparation Use knockouts 12 5 and 6 when installing the TS 50 Do not use knockouts 3 4 7 and 8 when preparing the TS 50 for installation 2 4 Mounting Mount the TS 50 with screws through holes provided in bottom corners of the can The unit should be screwed to a solid surface firmly enough to hold its weight during vehicle operation 2 5 Electrical Connections A Attach an 8 gauge chassis ground wire to the transfer switch ground bar A direct access hole to the ground bar is provided through the enclosure for convenience B Determine proper connections of wire conductors to electrical terminals On 120 VAC wiring the ground wire is bare or green the neutral wire is white and the hot wire is black On 240 VAC wiring there are two hot wires one is black and the other is red C Strip the outer jacket from all of the incoming cables Strip insulation from all ends of the copper conductors Insert cables through clamps in openings Do not tighten cable clamps at this time GP TS 50 D Route internal ground wires around lower area of enclosure and secure to ground wires away from electrical contacts on components to avoid the possibility of electrical short circuit E Connect the ground wires to the ground bar Tighten terminals to a minimum of 20 inch pounds F Connect the neutral white wire connections G Connect the hot wire s If there is a black wire and a red wire for 240 VAC it do
Download Pdf Manuals
Related Search
Related Contents
Mode d`emploi pour les sites naturels et culturels de la Haute ChristmasGift Ideas 2015 Robolinho© 100 MANUEL D`UTILISATION Manual de instrucciones y programación del Manuals - OMEGA Engineering Grundig 26 VLE 7201 BH 26" HD-Ready Smart TV Wi-Fi Black liquidos y polvos AXIS P7214 User Manual Samsung MAX-DG56T Manual de Usuario Copyright © All rights reserved.