1. Analog Rocking Shaker amp 3D Shaker User Manual KRS 3016 Analog Rocking Shaker KDS 3016 Analog 3D Shaker Please read carefully before use and follow all operating and safety instructions The design and specifications are subject to change without prior notice Laboratory Equipment Manufacturer www mrclab com CE li iNet Contents PEC TAC EN SS BV LC naaa EN SEN ba WAI TAY eE AAE E OE ER be Safety INSWUCH ONS kapen Eroen e EA NEA NE 2 PORN 3 PA 3 1 Receiving Inspection rnwrnnnnvrnnrrnnuvrnnnennuvsnnnenne 3 2 Listing of CMS pamana NAN aaron AS Color F OPO AA NE AE o Fa 7 Maintenance and Cleaning ssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnne 8 Associated standards and regulations cssss 2 Spe CMI CAC Os NE EN 10 Order Information ccccccececcsccececsecenceceecesseces Preface Welcome to the Analog Rocking Shaker amp 3D Shaker User Manual Users should read this manual carefully follow the instructions and procedures and beware of all the cautions when using this instrument Service When help needed you can always contact the service department of manufacturer for technical support in the following ways MRC Laboratory Instruments Limited Tel 972 3 5595252 Fax 972 3 5594529 E mail mre mrclab com Http www mrclab com Please provide the customer care representative with the following information e Serial number on the rear
2. angle 7 US plug 100V 240V 50Hz 60Hz KRS 3016 Analog Rocking Shaker See saw wave angle 7 CN plug 100V 240V 50Hz 60Hz KRS 3016 Analog Rocking Shaker See saw wave angle 7 Euro plug 100V 240V 50Hz 60Hz KRS 3016 Analog Rocking Shaker See saw wave angle 7 UK plug 100V 240V 50Hz 60Hz 834112010000 834112110000 834112210000 834112310000 KDS 3016 Analog 3D Shaker 3D gyratory angle 7 US plug 100V 240V 50Hz 60Hz KDS 3016 Analog 3D Shaker 3D gyratory angle 7CN plug 100V 240V 50Hz 60Hz KDS 3016 Analog 3D Shaker 3D gyratory angle 7 Euro plug 100V 240V 50Hz 60Hz KDS 3016 Analog 3D Shaker 3D gyratory angle 7 UK plug 100V 240V 50Hz 60Hz Accessories Cat No 18900025 18900026 18900038 18900039 18900029 18900030 18900031 Descriptions SK 180 1 attachment with 3 bars Universal SK180 2 attachment Fixing clip SK180 3 Lengthways roller attachment SK180 4 Dish Attachment with non slip mat Fixing clip for flask volume 25 ml Fixing clip for flask volume 50 ml Fixing clip for flask volume 100 ml Fixing clip for flask volume 200 250 ml 18900032 Fixing clip for flask volume 18900033 pe 500 ml Bar for SK180 1 Universal pp 18900037 attachment black
3. panel e Certification e Description of problem 1 e hardware or software e Methods and procedures adopted to resolve the problems Your contact information Warranty This instrument is warranted to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the date of invoice The warranty is extended only to the original purchaser It shall not apply to any product or parts which have been damaged on account of improper installation improper connections misuse accident or abnormal conditions of operation For claims under the warranty please contact your local supplier You may also send the instrument directly to manufacturer enclosing the invoice copy and by giving reasons for the claim 1 Safety Instructions A Warning Read the operating instructions carefully before use e Ensure that only trained staff works with the instrument Protective ground contact e Ensure the socket must be grounded protective ground contact before use When working wear personal safety guards to avoid the risk of Splashing liquids Broken glass containers Follow the safety instructions guidelines and accident prevention regulations Do not touch the running parts moving instrument care not rolling your fingers Set up the instrument in a spacious area on a stable clean non slip dry and fireproof surface Do not operate the instrument in explosive atmospheres wi
4. d Motor speed cannot reach set value M Check whether it is overloaded Maintenance and Cleaning Proper maintenance can keep instrument working properly and lengthen its lifetime Do not spray cleanser into the instrument when cleaning Do not remove the power line when cleaning Only use recommended cleansers Dyes Isopropyl alcohol Construction Water containing tenside Materials Isopropyl alcohol Cosmetics Water containing tenside Isopropyl alcohol Foodstuffs Water containing tenside Fuels Water containing tenside e Before using other method for cleaning or decontamination the user must ascertain with the manufacturer that this method will not damage the instrument Wear the proper protective gloves during cleaning of the instrument Note e Electronic device cannot clean with cleanser e Tf you require maintenance service must be cleaned the instrument in advance to avoid pollution of hazardous substances and to send back into original packing e If the instrument will not use for a long time please switch off and place in a dry clean room temperature and stable location 8 Associated standards and regulations Construction in accordance with the following safety standards EN 61010 1 UL 3101 1 CAN CSA C22 2 1010 1 EN 61010 2 10 Construction in accordance with the following EMC standards EN 61326 1 Changes or modifications not expressly approved by the party responsible for complianc
5. e could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense 9 Specification Specifications Items KRS 3016 Voltage VAC 100 240 Frequency Hz 50 60 Motor rating l 16 input W Motor rating 10 output W Tile Angel Max Shaking Weight kg Motor Type DC motor Speed range rpm 0 80 Dimensions W xHxD mm Weight kg 2 4 330X270X120 Permissible ambient Colt temperature C Permissible relative 8090 KDS 3016 100 240 50 60 16 10 DC motor 0 80 330X270X130 32 5 40 80 Items humidity Protection class acc DIN EN60529 10 Order Information Cat No 833132010000 833132110000 833132210000 8331323 10000 Specifications KRS 3016 KDS 3016 IP21 IP21 Descriptions KRS 3016 Analog Rocking Shaker See saw wave
6. s please contact manufacturer supplier for technical support N Note If there is any apparent damage to the system please do not connect to the power line 3 2 Listing of Items Items Qty Main unit 1 Power cable 1 User manual 1 Table 1 4 Control Shaking table knob Power light Power switch Power Interface Figure I Rocking shaker Speed control knob Power light Power switch Power Interface Figure 2 3D shaker Speed control knob Power switch Power interface Power light 5 Items Descriptions Set target speed Switch ON OFF instrument Connect the power cable Green LED display light Table 2 Operation Place the instrument in safe and stable surface ensure the required operating voltage and power supply voltage matched Connect the power cable Install the platform Switch ON the instrument Rotate the speed control knob clockwise to set target speed and the shaking function will be switched on Rotate the speed control knob to the left most position to switch off the shaking function Switch OFF the instrument If these operations above are normal the instrument is ready to operate If not the instrument may be damaged during transportation please contact technical support of manufacturer supplier A Note The speed value can be altered during shaking Faults When switched ON the instrument does not work mM Check whether the power cable is connecte
7. th hazardous substances or under water If the instrument does not run smoothly please decrease the motor speed Firmly secure the accessories and vessels in place to avoid damage or risk Preparation of samples may lead to dangerous flammable Only process samples that will not react dangerous Use the standard accessories listed in the accessories section and follow the instructions to use accessories to ensure safety Please switch off the power before assembly of accessories confirm the instrument and accessories are intact before switch on each time The instrument only be opened by expert please switch off before use The voltage stated on the nameplate must correspond to the mains voltage Do not cover the instrument during running Prevent the collision and extrusion to instrument and accessories Keep away from high magnetic field 2 Proper Use The instrument is designed for mixing sticky substance in schools laboratories or factories It can be installed on a variety of impeller for different viscosity of the medium This instrument is not suitable for using in residential areas or other constraints mentioned in Chapter 1 Do not use the accessories recommended by the manufacturer or failure to use the instructions may be caused unsafe situation 3 Inspection 3 1 Receiving Inspection Unpack the instrument carefully and check for any damages which may have arisen during transport If it happen

Download Pdf Manuals

image

Related Search

Related Contents

Samsung GT-I7500 Benutzerhandbuch  Scanner a colori Manuale Dell`utente  KitchenAid KRFC302EPA Use and Care Manual  TFD-1506DVBT_ACDC Spanish ok dh 23062008  Additel/LogII Wireless Data Logging Software User Manual  From The N3UJJ.COM Document Library  Samsung SGH-F480T User Manual  KRAM Audio2Car Premium  Supermicro X7DCT  User`s Manual - Edge-Core  