Home
G7 BR2 Rangefinder Manual
Contents
1. 18 Focus Adjustment Ring 18 Firmware Revision Number 19 Measuring Point 19 Neck Strap 20 Restore Default Settings 21 Section 4 System Setup Menu 20 Ballistic Profile Menu 23 Backlight Menu 24 Cross Hair Display Menu 25 Section 5 Taking a Range Only Measurement 26 Measurement Results Menu in the Range Only Mode 27 Section 6 Setting up a Ballistic Profile 28 3 Section 7 Taking a Ballistic Profile Measurement 3
2. 43 G7 BR2 Owner s Manual First Edition Part Number 0144859 Copyright Notice Information in this document is subject to change without notice and does not represent a commitment on the part of Gunwerks LLC No part of this manual may be repro duced in any form or by any means electronic or mechanical including photocopying recording or information storage and retrieval systems for any purpose other than the purchaser s personal use without the express written consent of Gunwerks LLC Copyright c 2011 Gunwerks LLC All Rights Reserved Unauthorized duplication in whole or in part is strictly prohibited First Edition September 2011 Patents This product is covered by pending patent applications and or the following issued U S Patents 6 445 444 5 612 779 6 057 910 6 226 077 7 349 073 8 001 714 Trademarks TruPulse is a registered trademark of Laser Technology Inc Gore Tex is a registered trademark of W L Gore and Associates All other trademarks are the property of their respective owners Gunwerks Contact Information PO Box 22 Burlington WY 82411 Phone 307 762 3240 Fax 866 330 0790 Email customerservice gunwerks com 4 Foreword Dear Customer Gseven is a Gunwerks brand whose sole purpose is to change the long range shooting game To create and build products for the first shot Your new ballistic rangefinder offers features and functionality that have never been offered in a h
3. Carrying case Neck strap Understanding How the G7 BR2 Works Measurements of all sensors are recorded every time the button is pressed and released In addition to the rangefinding circuitry the G7 BR2 Ballistic Range finder samples air pressure temperature and inclination angle Ballistic Compensation The G7 BR2 Rangefinder combines best in class ranging capability with an ad vanced ballistic computer to measure the range to target and calculate a complete ballistic solution The G7 BR2 was designed to be very simple to use offering a one button press to both measure and calculate your ballistic solution Once the unit has been programmed and the Main Display is shown press and hold the Fire button until a range measurement in displayed When configured in BDC mode the Line Of Sight distance will be displayed for approximately two seconds and then the compensated range is displayed A small C to the left of the distance indicator will distinguish a compensated distance from a line of sight distance Use the compensated distance in conjunction with a Ballistic Turret If you have configured the device to calculate and display your ballistic solution in Minutes of Angle MOA the MOA correction is displayed with MOA indicated in the top right section of the Upper Display The calculated wind correction is easily accessed and displayed in 5 or 10 mph increments After ranging and receiving a ballistic solution pressing either
4. Low Battery Warning The G7 BR2 monitors the incoming battery voltage Figure 7 shows the location of the battery status in dicator It is located on the right side of the LCD just above the yards indicator When the voltage drops below 2 6V the battery status indicator is displayed o You should replace the battery as soon as pos sible o Although the unit operates at this level it is recommended that you install a new bat tery before the setup or update of a ballistics profile Data may be lost if the system shuts down before this process is complete When the voltage drops below 2 4V system opera tion is locked and then shuts down o You must replace the battery to return to normal system operation If the system shuts down during the process of setting up or updating a ballistic profile entered data will be lost and will have to be re entered 12 Buttons The G7 BR2 has a 4 button keypad located on the top panel of the instrument The buttons provide easy access to the instrument functions programming and operating commands This manual refers to the buttons while the laser is oriented as shown in Figure 8 System Set up Menu and sub menus System Set up Menu and sub menus Measurement Mode Measurement Mode Sleep Mode Sleep Mode Edit Mode Edit Mode Selects the displayed menu option Initiates measurement Wakes up instrument When a Ballistic Profile Description is displa
5. Never attempt to view the sun through the scope Looking at sun through the scope may permanently damage your eyes Never point the unit directly at the sun Exposing the lens system to direct sunlight even for a brief period may permanently damage the internal components Avoid direct sun exposure on the eyepiece Exposing the eyepiece to direct sunlight can damage the internal dis play Do not expose the instrument to extreme temperatures G7 BR2 components are rated for an operating temperature range of 32 to 122 F and a storage temperature range of 4 to 158 F 6 Section 1 Introducing the G7 BR2 Congratulations on the purchase of your G7 BR2 the first rangefinder to feature a real time ballistic calculation that accepts your specific bullet Ballistic Coefficient BC and Muzzle Velocity MV as inputs to build a custom ballistic profile and then calculate a real time ballistic solution based on measured environmental and sighting conditions Range Only Mode for shooters that need range only information Presented as horizontal distance and includes basic range with up down hill angle to target cor rection Ranges to 1 400 yards Ballistic calculations are powered by the advanced G7 ballistic engine The precise algorithms are configured to allow ultra fast real time calculations as Shoot To Range or MOA Compensation Shoot To range compensates the line of sight range for variations in air density an
6. Powering OFF the G7 BR2 To conserve battery power if no button presses are detected after a specified length of time the G7 BR2 will enter Sleep Mode and then turn itself OFF Sleep Mode 8 seconds Shut Down 45 seconds Note These times are after the last button press or major instrument operation such as storing ballistic profile data 14 Display Indicators Figure 9 shows the LCD in scope display The G7 BR2 s internal software is organized into options Each option represents a specific measurement or setup function and has a cor responding display indicator Refer to Figure 9 and the table below for information about each indicator Upper Display Battery Voltage Measurement Units Lower Display n a Laser Displays menu items and messages Low battery warning page 11 Y Yards M Meters not active in the G7 BR2 F Feet or Fahrenheit Displays messages and measurement results Although part of the display not active in the G7 BR2 The instrument s laser is firing 15 Measuerment Modes Range Only Measurement Measurement with Ballistic Profile The crosshair and yard indicator are displayed and appears in the Lower Display See page 26 for information about taking a range only measurement Data measurements and calculated values are displayed in the Measured Values Menu The G7 BR2 allows you to store 5 different cartridge combinations The ballistic profile i
7. 122 F Minimum Temperature for Computed Ballistics 32 F Maximum Pressure for Computed Ballistics 36 InHg Minimum Pressure for Computed Ballistics 4 InHg Optical System Field of View 340 feet at 1 000 yards Type Monocular thru the lens view coincident with laser output beam Magnification 7X 42 Miscellaneous Operating Temperature 32 to 122 F Storage Temperature 4 to 158 F Power Source CR 123 Battery Life Intensive use and brightness 4 5 hours Average use 8 10 hours Dimensions 5 2 L x 4 5 W x 2 1 H in 13 2 L x 11 4 W x 5 3 H cm Weight with battery 0 90 lbs 0 40 kg Structure Glass filled polycarbonate composite Targeting Modes Standard Near Far Continuous Environmental Waterproof dustproof IP55 Laser Class FDA Class 1 CFR 21 Wavelength 905 nm 43 Section 11 Troubleshooting Problem Remedy The unit does not power ON or the LCD does not illuminate Press the button Check the display and if necessary replace the battery Make sure the unit is powered ON Make sure that nothing is obstructing the trans mit lens or the receive lens Make sure the unit is held steady while pressing the button Make sure that you press and hold as long as the laser is active 5 second maximum To conserve battery power if no button presses are
8. Adjust the Focus Adjustment Ring until the crosshair is at its optimum focus or sharpness For future reference note the position of the scale on the Focus Adjustment Ring 19 Firmware Revision Number The firmware revision number provides manufacturing information about your G7 BR2 To display the firmware revision number 1 Start with the G7 BR2 powered OFF press the button 2 Look through the eyepiece and press to display the firmware revision number The display should look similar to Figure 12 3 Press the button or button to clear this display Figure 12 uses firmware revision 2 10 for the purpose of an example Your G7 BR2 may include a different firmware revision number Measuring Point The measuring point of the BR2 is located at the center point of the instrument the 20 thread 20 Neck Strap 1 Find the two Attachment Points located on the rear panel of the BR2 2 Insert the end of one of the connector straps into one side of the eyelet opening and feed it through to the other side 3 Feed the strap up from the bottom of the buckle then over the center of the buckle and back down through the other side 4 Pull the strap to take up any slack and tighten the strap to simply have a loop that is fed through the eyelet 5 Repeat steps 2 4 to attach the other connector strap to the other side of the G7 BR2 6 Attach one end of the neckstrap into the side release buckle of one of the conne
9. ballistic turret or MOA turret should be adjusted to reflect 2 for 200 yards or 0 respectively See page 36 for information about the Edit Mode Notes Be certain to double check all entries The program does not check val ues so invalid entries do not generate an error message Highly accurate scope and ballistics data are supplied when you purchase a complete rifle system from Gunwerks Use the Ballistics Calculator at www gseven com to determine your bal listics data If you are tuning and developing your own loads and rifle setup the better you can resolve your BC MV etc the better the performance you will get from your laser If BC and MV values are set to 0 the unit will auto clear the user entered profile name and usually reset to the factory default example Profile 1 31 Section 7 Taking a Ballistic Profile Measurement Setup the ballistics profile to match the cartridge combination page 23 The basic steps for taking a Ballistic measurement are the same as taking a Range Only mea surement page 26 For range measurements with ballistic calculations the maxi mum measurement distance is approximately 1 400 yards Measurement results vary depending upon the Drop Units selection associated with the ballistic profile After completing a measurement the calculated wind correc tion is easily accessed After ranging and receiving a ballistic solution pressing either the or will display the
10. detected after a specified length of time the G7 BR2 will enter Sleep Mode and then power itself OFF Sleep Mode 8 seconds Shut down 45 seconds Note These times are after the last button press or major instrument operation Review Ballistic Profile inputs If problem persists contact Gunwerks for as sistance See inside front cover for Gunwerks contact information Contact Gunwerks for service See inside front cover for Gunwerks contact information The target cannot be acquired The G7 BR2 does not have an OFF button Incorrect measurements E37 or similar value appears in the Main Display Section 12 Warranty The G7 BR2 is covered by the one year G7 Gunwerks Limited Warranty G7 offers a bulletproof product warranty All of the G7 products are built to very rugged performance standards and checked and rechecked before they are shipped If a G7 product should fail during normal use please contact G7 Customer Service Feel free to call or write with any questions you may have about our products To register your G7 BR2 please visit the G7 web site http www gseven com customer service warranty
11. Description 1 Display the System Setup Menu Pro file Select will be displayed 2 Press the button to display the Ballistic Profile Menu 3 Press or to scroll to the profile you wish to edit In this example we will edit Profile 1 4 Press the button to select the profile you wish to edit The factory de fault Profile 1 will appear in the Upper Display and dESc in the Lower Display 5 Press the button to start the Edit Mode The left most character of the Upper Display will be flashing 6 Press or to increase or decrease the value of the flashing character The auto accelerating editor scrolls faster the longer the button is pressed If you need to make a correction press the button repeatedly to return to the character that you want to correct 7 Press the button to scroll to the next character in the description Maximum 8 characters 8 Press the button to exit the Edit Mode The message Pls Wait appears in the Upper Display while the instrument calculates intermediate tables for the selected profile More than 1 profile may be setup before exiting the Edit Mode 9 Do not press any buttons until the Pls Wait message is cleared and the Mea surement Screen is displayed showing the updated profile number P1 in this example 39 Description 1 2 3 4 5 Profile Number Drop Units Drag Standard Ballistic Coefficient Muzzle Velocity Sight He
12. E 39 If you encounter an error code allow the unit to completely power OFF Then press the button to power ON the unit and repeat the intended measurement or action If the error persists contact Gunwerks Customer Service for assistance 18 Eyepiece The adjustable eyepiece is designed for comfort and to block extraneous light To extend the eyepiece turn the eyepiece counter clockwise while pulling up To return the eyepiece to its original position turn the eyepiece clockwise and push down To match your personal preference the eyepiece may be located in any position from fully up to fully down If wearing eyeglasses or sunglasses you will find that the fully down position brings the eyepiece lens closer to your eye and gives you a full field of view Eyepiece Cover The eyepiece cover protects the internal components from sunlight exposure The eyepiece cover should be in place whenever the G7 BR2 is not in use To attach the eyepiece cover Feed the thin cord under the metal bar and flare the loop open Pull the eyepiece cover through the loop and cinch tight Focus Adjustment Ring The focus adjustment ring see Figure 11 allows you to focus the LCD in scope display relative to the target for your eye During assembly opti mum focus is set to infinity To adjust the LCD focus turn the focus adjustment ring to suit your personal preference Power ON or wake up the G7 BR2 and then aim at a distant object
13. calcu lated wind hold in MOA for the ballistic solution Drop Units BDC 1 Look through the eyepiece and use the cross hair to aim to the target In this example P1 indicates that Ballistic Profile 1 is active and will be applied to the measurement 2 Press and hold the button The Laser status indicator is displayed while the laser is active The laser re mains active for a maximum of 5 seconds while acquiring data about the target If the target is not acquired in the 5 second period release the button and repeat this step 3 Once the measurement is displayed release the but ton The Line of Sight distance will be displayed for just a few seconds and then the display will be updated c will appear in the Lower Display to indicate the compensated distance or Shoot To Distance 4 Press the or button to display the Wind Correction Menu page 35 To apply this correction just dial or hold the correct value in the rifle scope Press the button to toggle between the Mea sured Values Menu and the Wind Correction Menu Press the button to the Measured Values Menu If the or button are pressed before the next measurement the last Wind Correction Value and Measured Value will appear 32 Measurement Results Menu in the BDC Mode Example Measured Values Menu Ballistic Profile Measurement BDC Distance Shoot To Distance Approximate Altitude Barometric Pressure Temperature Inclination Lin
14. eyepiece see Figure 4 and use the crosshair to aim to the target The in scope LCD should look similar to Figure 5A 5 Press and hold The LASER status indicator is displayed while the laser is active Figure 5B The laser will remain active for a maximum of 5 seconds while acquiring data about the target o If the target is not acquired release and repeat this step 6 Release once the distance is displayed Figure 5C In this example the h that proceeds the 100 yards indicates horizontal distance and Range Only Mode The measurement will be dis played for 8 seconds or until you press a button o Press or to scroll through the Mea sured Value Menu and see the results acquired for each function o Hor Dist horizontal distance yards o Aprx Alt approximate altitude feet o inHg barometric pressure o Temp temperature F o Incline inclination degrees o LOS Dist line of sight distance yards o Repeat steps 3 6 above to take another measurement 11 Section 3 Basic Operations Battery The G7 BR2 Rangefinder is powered by a 3 Volt Lithium battery commonly referred to as CR123A or also referred to as CR123 1 Remove the Battery Compartment Cover by lifting up the Hinged Tab and turning coun ter clockwise 2 Insert the battery negative end first 3 Re insert the Battery Compartment Cover and use the Hinged Tab to turn clockwise 4 Press down on the Hinged Tab to secure
15. the or button will display the calculated wind hold in MOA for the ballistic solution While in the Wind Correction Menu pressing either of the selection buttons increments the wind value up or down from 5 to 50 mph and displays the corresponding wind correction To apply this correction just dial or hold the correct value in the rifle scope 8 LCD Display A liquid crystal display LCD is mounted within the optical system and when activated displays a reticle for targeting yards and the display indica tors Inherent in the manufacturing process are small black spots that appear in the optical system These are a natural characteristic of the LCD and can not be fully eliminated in the manufacturing process These small black spots do not affect the distancing performance of the unit Laser Range Sensor The laser range sensor emits invisible eye safe infrared energy pulses The G7 BR2 determines distance by measuring the time it takes for each pulse to travel from the rangefinder to the target and back The laser indicator is displayed whenever the laser is being transmitted The laser may be active for a maximum of 5 seconds Once the target is acquired or the laser has timed out you can release the button TruTargeting The G7 BR2 automatically provides the best accuracy and acquisition dis tance to a given target Maximum measurement distance varies with target quality and environmental conditions For Range Only measuremen
16. 1 Drop Units BDC 31 Measurement Results Menu in the BDC Mode 32 Drop Units MOA 33 Drop Units Inches 34 Wind Correction Menu 35 Section 8 Edit Mode 36 Lower Display 36 Upper Display 37 Editing a Ballistic Profile Description 38 Section 9 Care amp Maintenance 40 Section 10 Specifications 41 Section 11 Troubleshooting 43 Section 12 Warranty
17. 2 Table of Contents Foreword 4 Precautions 5 Section 1 Introducing the G7 BR2 6 Unpacking the G7 BR2 7 Understanding How the G7 BR2 Works 7 Ballistic Compensation 7 LCD Display 8 Laser Range Sensor 8 TruTargeting 8 Altimeter 8 Temperature Sensor 8 Inclination Sensor 9 Digital Processor 9 Eyepie
18. The F display indicator appears in the left edge of the Upper Display The unit logs all targets found in the area of the crosshair while the button is held down Brackets surround the cross hair briefly to indicate multiple targets acquired Of the targets acquired the distance to the farthest target appears in the lower display 17 Error Codes Error conditions can occur in a measurement or in the system hardware To make sure that you never get an erroneous measurement the G7 BR2 monitors both system hard ware and measurements The temperature and pressure sensors will display null values if an error is encountered or values are out of range Error codes appear in the main display and are in the form of E xx where xx is an error code number Figure 10 shows an example error code E 32 The Clear message that appears in the Upper Display is prompting you to press the button to restore default settings Error Codes Explanation E 31 Checksum error for factory fixed parameter E 32 Checksum error for user stored data Restore default settings to clear this error see above E 33 Unit failed self test during power ON sequence E 34 Unit failed the built in PLL test E 35 Processor failed to show current measurement complete within the timeout limit E 36 Tilt sensor reading is outside maximum workable range E 37 Calibration error Contact Gunwerks Customer E 38 Service for assistance
19. ce 9 In scope LCD 9 Section 2 Quick Start 10 Section 3 Basic Operations 11 Battery 11 Low Battery Warning 11 Buttons 12 Powering OFF the G7 BR2 13 Display Indicators 14 Measurement Modes 15 Target Selection Menu 16 Error Codes 17 Eyepiece
20. ctor straps 7 Attach the other end of the neckstrap to the side release buckle of the other connector strap Make sure the strap is straight when attaching it to the G7 BR2 This will help you avoid uncomfortable twists in the strap that will rub your neck Before use check to make sure the neckstrap is secure Failure to do so may result in the BR2 hitting the ground or other object The neckstrap may also be attached to the carrying case 21 Restore Default Settings It is possible to restore the G7 BR2 s default settings Restoring the default settings affects the system setup options The table below lists the parameters and the associated default setting Parameter Measurement Mode Target Type Back Light Cross Hair Profile Descriptions Drop Units Drag Standard Ballistic Coefficient Muzzle Velocity Sight Height Turret Temperature Turret Altitude Zero Range 100 0 0 0 G1 MOA Profile 1 Profile 5 Level 2 Standard Range Only 60 1 5 Default Value To restore the default settings the unit must be powered OFF 1 Press the button 2 Press the button The firmware revision number will be displayed 3 Press the button Clear will appear in the Upper Display 4 Press the button if you want to restore the default settings Press the button if you want to cancel the operation 22 Section 4 System Setup Menu Figure 15 shows an ov
21. d inclination angle The output is specific to the programmed BC and MV Shoot To range is configured to work with BDC turrets Minute of Angle MOA Correction calculates and outputs the ballistic correction in MOA units Most rifle scope turrets are calibrated in MOA units MOA wind correction values are calculated and easily accessed to display the cor rection for different wind values Onboard sensors measure incline angle barometric pressure and temperature These sensors provide the data to the G7 ballistic engine to calculate the Shoot To Range or MOA Correction Programmable for up to five different cartridge combos Specific inputs include Ballistic Coefficient Muzzle Velocity and Sight Height Altitude and Temperature are also provided when programming for a BDC turret Very simple intuitive display offers selectable reticles and four intensity settings for varying light conditions The Backlit LCD display is visible in bright light and low light conditions The rugged housing is weatherproof and features a Gore Tex membrane The tripod mounting stud is 20 on the bottom of the housing The eyepiece features an adjustable focus with a click adjustable twist up eye cup 7 Unpacking the G7 BR2 When you unpack your new G7 BR2 check to make sure that you received ev erything that you ordered and that it all arrived undamaged G7 BR2 Eyepiece cover User s Manual on CD
22. dit Mode Drop Units Bullet Drop Compensator BDC Corrects the LOS Range to your Ballistic Profile and field conditions for a Shoot To Range The Shoot To Range is for use with a calibrated Ballistic turret Just dial or hold the appropriate calibra tion Minutes of Angle MOA Standard units of angular correction for field adjustable height and windage turrets Returns the MOA correc tion for the ballistic solution to hold or dial on a standard MOA reticle or turret Just dial or hold the appropriate calibration Inches Correction for sight in only turrets User estimates dimension at target 29 Drag Standard G1 The industry standard G7 Most modern long range bullets fit this model Use the G1 model unless you have an accurate Bal listic Coefficient based on the G7 standard G1 and G7 are not interchangeable Ballistic Coefficient BC All bullet manufacturers list a BC for their bullets This number describes the bullet s efficiency in overcoming air resistance A higher number is better Usually the number is less than one for example Berger 7mm 168 VLD G1 is 0 617 Be sure to use the Ballistic Coefficient appropriate to the selected Drag Standard G1 or G7 If you are using a Ballistic turret use the BC from that profile See page 35 for information about the Edit Mode Muzzle Velocity MV The MV is the speed the bullet leaves the barrel unit is feet pe
23. e of Sight Distance 33 Measurement Results Menu in the BDC Mode Example Measured Values Menu Ballistic Profile Measurement Drop Units MOA In this example the figures to the right show Profile 1with Drop Units of MOA The process of taking the measure ment is the same as BDC Mode The first value displayed represents the Line of Sight Distance In this example 224 yards The next value displayed is the MOA correction value for bullet drop 1 7 MOA in this example The Measured Value Menu includes MOA Drop Approximate Altitude Barometric Pressure Temperature Inclination Line of Sight Distance Press the or button to display the Wind Correction Menu page 35 To apply this correction just dial or hold the correct value in the rifle scope Press the button to toggle between the Measured Values Menu and the Wind Correction Menu Press the button to the Measured Values Menu If the or button are pressed before the next measurement the last Wind Correction Value and Measured Value will appear 34 Drop Units Inches In this example the figures to the right show Profile 1 with Drop Units of Inches The process of taking the measurement is the same as BDC or MOA mode The first value displayed represents the Line of Sight Distance In this example 223 yards The next value displayed is the Inches correction value 4 inches in this example The Measured Value Menu
24. erview of the System Setup Menu which can be accessed from the Measurement Mode Each option is described separately in the following sections 1 From the Measurement Mode press and hold the button for 3 seconds Profile will appear in the Upper Display and SELEct will appear in the Lower Display 2 Press or to display the previous or next option Press the button to return to the Measurement Mode 3 Press to select an option Press the button to return to the Measurement Mode 23 Ballistic Profile Menu The G7 BR2 allows you to define five custom ballistic profiles The Ballistic Profile Menu allows you to select Range Only measurements or to select review or edit a ballistic profile 1 From the Measurement Mode press and hold the button for 3 seconds Profile will appear in the Upper Display and SELEct will appear in the Lower Display 2 Press to display the current pro file selection 3 Press or to display the previ ous or next option 4 Press to select a Profile Press or to review the settings associated with the profile See page 27 for information about editing a ballistic profile When finished press the button to return to the Profile Selection Menu You must press button again to return to the System Setup Menu Pressing the again will return to the Measurement Mode Each time the G7 BR2 is powered ON it will return to the same profile selec ti
25. ight Turret Temperature Turret Altitude Zero Range 40 Section 9 Care amp Maintenance The battery is the only user replaceable part in the G7 BR2 Do not remove any screws To do so will effect or void the G7 Gunwerks Limited Warranty Temperature Range Operating temperature range 32 to 122 F Storage temperature range 4 to 158 F Protecting from Moisture and Dust The G7 BR2 is sealed to provide protection from normally expected field conditions It is protected from dust and rain but will not withstand submersion If water leakage is suspected 1 Power OFF the G7 BR2 2 Remove the battery 3 Air dry the G7 BR2 at room temperature with the battery compartment open Protecting from Shock The G7 BR2 is a precision instrument and should be handled with care It will with stand a reasonable drop shock If the unit suffers from a severe drop shock power on the unit and attempt a measurement Please contact G7 Customer Service if you need assistance Transporting When transporting the G7 BR2 the unit should be secured in the provided carrying case The provided neck strap can be used when carrying the G7 BR2 in the field The eyepiece cover should be in place whenever the G7 BR2 is not in use Cleaning Clean the G7 BR2 after each use before returning it to its carrying case Check all of the following items Excess moisture Towel off excess moisture and air dry the instrument at room te
26. includes IN Drop Approximate Altitude Barometric Pressure Temperature Inclination Line of Sight Distance Press the or button to display the Wind Correction Menu page 35 To apply this correction just hold off the correct value in the rifle scope Press the button to toggle between the Measured Values Menu and the Wind Correction Menu Press the button to the Measured Values Menu If the or button are pressed before the next measurement the last Wind Correction Value and Measured Value will appear 35 Wind Correction Menu Entering the Wind Correction Menu is accomplished by pressing the or buttons after a measurement sequence has been accomplished in BDC MOA or Inches Mode While in the Wind Correction Menu pressing either or increments the wind value up or down from 5 to 50 miles per hour and displays the corresponding wind correction Select the wind correction that best approxi mates the right angle component to your shot direction To apply this correction just dial or hold the correct value in the rifle scope If Drop Units BDC or MOA the correction value is in MOA If Drop Units Inches the correction values in inches Press the button to toggle between the Measured Values Menu and the Wind Correction Menu 36 Section 8 Edit Mode The G7 BR2 has an editor that can be used to manually enter values for the various instrumen
27. mperature with the battery removed and the battery compartment open Exterior dirt Wipe exterior surfaces clean to prevent grit buildup in the car rying case Isopropanol may be used to remove dirt and fingerprints from the exterior Transmit and Receive Lenses Use the provided lens cloth to wipe the lenses Failure to keep the lenses clean may damage them Storing If you won t be using the G7 BR2 again soon remove the battery before storing the instrument 41 Section 10 Specifications All specifications are subject to change without notice Please refer to Gunwerks website for current specifications If you are not able to locate the information on the website or if you do not have internet access please contact Gunwerks via phone or fax Refer to the inside front cover for Gunwerks contact information Measurement System Measurement Range 0 2 500 yards Functional Range 2 000 yards Reflective Range 2 500 yards Maximum Compensated Range 1 400 yards Accuracy Range 1 yard Tilt 1 degree Temperature 2 F Pressure 0 5 InHg Measuring System 905 nm infrared pulse laser Display System Black mask dot matrix LCD with in scope projection Target System In scope projection of aiming reticle Ballistics Calculation Limits Maximum Tilt Angle for Computed Ballistics 90 Deg Maximum Temperature for Computed Ballistics
28. ndicator appears in the far right of the Upper Display In this example P1 represents Profile 1 See page 28 for information about setting up a ballistic profile See page 31 for information about taking a measurement with a ballistic profile 16 Target Selection Menu The G7 BR2 allows you to select or eliminate targets and to take the most accurate measurements possible in various field conditions When the mea surement screen Range Only or Ballistic Profile is displayed press the button to increment through the Target Selection Menu Standard Continuous Nearest Farthest Standard single shot strongest target mode The c display indicator appears in the left edge of the Upper Display The unit logs found in the area of the crosshair while the button is pressed The results are up dated in the lower display as each target is acquired Allows for easy acquisition of small targets without inadvertently getting background targets that have stronger signal strength The N display indicator appears in the left edge of the Upper Display The unit logs all targets found in the area of the crosshair while the button is held down Brackets surround the cross hair briefly to indicate multiple targets acquired Of the targets acquired the distance to the nearest target appears in the lower display Allows objects such as brush or tree branch es to be ignored so that only background targets are acquired
29. on that was last used 24 Backlight Menu The G7 BR2 has a backlit LCD display with an adjustable intensity to match viewing and ambient light conditions The Back Light Menu has 4 levels of intensity or brightness 1 From the Measurement Mode press and hold the button for 3 seconds Profile will appear in the Upper Display and SELEct will appear in the Lower Display 2 Press or to display the Backlight Menu as shown in the figure below 3 Press to display the current Backlight setting 4 Press or to increase or decrease the value Backlight setting 5 When finished press the button to save the Backlight set ting and return to the System Setup Menu You must press the button again to return to the Measurement Mode Each time the G7 BR2 is powered ON it will return to the same backlight level that was last used 25 Cross Hair Display Menu To fit your application the G7 BR2 offers three options for displaying the cross hair 1 From the Measurement Mode press and hold the button for 3 seconds Profile will appear in the Upper Display and SELEct will appear in the Lower Display 2 Press or to display the Cross Hair Display Menu 3 Press to display the current cross hair selection 4 Press or to display another cross hair option 5 When finished press the button to save the Cross Hair selection and return to the System Setup Menu You must press the but ton again to ret
30. other measurement press the button exit the Measured Values Menu and return to the Measurement Mode Press the button a second time to fire the laser Until the laser is fired you may press either the button or button to return to the Measured Values Menu 27 Measurement Results Menu in the Range Only Mode Example Measured Values Menu Range Only Measurement Horizontal Distance Apporximate Altitude Barometric Pressure Temperature Inclination Line of Sight Distance 28 Section 6 Setting up a Ballistic Profile The BR2 allows you to define and store five ballistic profiles 1 In the Profile Select Menu select the ballistic profile that you want to review or edit page 23 2 Press or to display the previous or next option 3 Press the button to select an item that you want to change Edit the value or Press or to display the previous or next option Press the button to save the selection and return to the Profile Select Menu Press button again to calculate and store the ballistic profile Pls Wait is displayed during this process which will take approximately 14 seconds o You will have to press the button one more time to return to the Measurement Mode Description Press the button to enter a descriptive label or name for the ballistic profile cartridge caliber or load description Maximum of 8 characters See page 36 for information about the E
31. r second and automatically corrects for a measured chronograph distance of 15 feet If you are unable to measure your MV go to www gseven com and use the trajectory validation feature to calculate your actual MV based on shooting re sults If you are using a Ballistic Turret use the MV from that profile See page 35 for information about the Edit Mode Sight Height The distance from the center line of the barrel to the centerline of the scope unit is inches It is easy to measure Add half the diameter of the scope to half the diameter of the action to the distance between the scope and action Or place a ruler on the side of your rifle and estimate See page 35 for information about the Edit Mode 30 Turret Temperature The temperature the Ballistic turret was config ured for Unit is degrees Fahrenheit See page 36 for information about the Edit Mode Turret Altitude The Altitude the Ballistic turret was configured for Unit is feet See page 36 for information about the Edit Mode The Zero Range The range at which your calibration for drop compensation is referenced Usually consider ing the point blank range of your cartridge 200 yards is a common and useful zero range Your MOA elevation adjustment Ballistic Turret or Ballistic Reticle should reflect and reference your zero range For example with your rifle sighted in at 200 yards to hit right on the bulls eye your
32. s ambient tem perature Inclination Sensor The inclination sensor is located inside the housing of the G7 BR2 rangefind er When the rangefinder is aimed at an object and the range is obtained by depressing the Fire button the inclination angle to the target is determined Digital Processor The G7 BR2 includes LTI s proprietary ASIC chip Application Specific In tegrated Circuit The ASIC chip combined with high speed CPU processing allows the G7 BR2 to deliver accurate and fast measurements Eyepiece The eyepiece is located at the back of the G7 BR2 and includes a 7X magnification scope In scope LCD The In scope LCD displays menu items option indicators error codes and measure ment results Figure 2 shows the in scope LCD with all display segments lit Each time the instrument is powered ON all display segments are lit for just a couple of seconds If it appears that not all display indicators are working properly please contact Gun werks Customer Service for assistance The G7 BR2 has multiple options for the display of the cross hair page 24 Figure 3 shows the factory default cross hair In this example the BR2 is ready to take a Range Only measurement 10 Section 2 Quick Start 1 Install the battery page 9 2 Press to power ON the G7 BR2 3 Select a target such as a tree or a building For this example the target should be ap proximately 100 yards 4 Look through the
33. t setup values The instrument does not check or validate entered values so it is recommended that you verify values before exiting the Ballistic Profile Menu Editable options include Profile Description Ballistic Coefficient Muzzle Velocity Sight Height Turret Temperature Turret Altitude Zero Range Restoring factory defaults will clear the stored values The table on page 39 may be used to record profile data Lower Display When all of indicators are lit the Lower Display looks like Figure 26 Numeric Values Figure 27 To edit a numeric value 1 Press the button One of the digits will be flashing 2 Press or to increase or decrease the value of the digit until desired value is displayed 3 Press the button to edit the next digit 4 Repeat steps 2 and 3 until correct value is displayed 5 Press the button to exit the Edit Mode 37 Upper Display Of the editable options listed on the previous page only the Profile Description is edited using the Upper Display When all of indicators are lit the Upper Display looks like the figure to the right The Profile Description is limited to 8 characters You may select from ASCII characters that include upper case letters A Z lower case letters a z numbers 0 9 and special characters amp lt gt _ blank space 38 Editing a Ballistic Profile
34. ts the maximum measurement distance is approximately 2 000 yards For range measurements with ballistic calculations the maximum measurement dis tance is approximately 1 400 yards When selecting a target you should consider the following Color The brighter the color the longer the range Finish Shiny finishes provide longer range than dull finishes Angle Shooting perpendicular to a target provides better range than shooting to a target at a sharp angle Lighting Conditions Overcast skies will increase the unit s maximum range and sunny skies will decrease the unit s maximum range Altimeter Your Ballistic Rangefinder is instrumented with a barometric pressure sensor that is mounted inside the housing A Gore Tex membrane allows accurate sampling of barometric pressure while maintaining a weatherproof seal This device measures relative pressure uncorrected to sea level this is station pressure A simple calculation converts the station pressure reading to an equivalent altitude for standard conditions Both the station pressure reading and equivalent altitude are available under the Measured Values Menu 9 Temperature Sensor The temperature sensor is located at the front of the unit under the rubber armor The front of the temperature sensor is exposed to ambient conditions but the device housing temperature can affect the accuracy of the reading There will be a slight response time delay as the unit reache
35. unting rangefinder before In addition to exceptional ranging capability the G7 BR2 offers real time ballistic calculations based on your specific Ballistic Coefficient BC and Muzzle Velocity MV Measurements for air pressure temperature and inclina tion are collected and then utilized in our sophisticated calculations to generate a precise ballistic solution out to 1 400 yards The correction can be applied with MOA output and a standard elevation turret or with a ballistic turret and the Shoot To Range output setting The G7 BR2 also offers the correct wind hold compensation using our patented windage technology to complete the most precise ballistic solu tion available in the industry We wish you success and perfection in your shooting To take advan tage of the ballistic capabilities make sure you review this manual in its entirety Aaron Davidson President Gunwerks LLC 5 Precautions Avoid staring directly at the laser beam for prolonged periods The G7 BR2 is designed to meet FDA eye safety requirements and is classified as eye safe to Class 1 limits which means that virtually no hazard is associated with directly viewing the laser output under normal conditions As with any laser device however reasonable pre cautions should be taken in its operation It is recommended that you avoid staring into the transmit aperture while firing the laser The use of optical instruments with this product may increase eye hazard
36. urn to the Measurement Mode Each time the G7 BR2 is powered ON it will return to the same cross hair display that was last used 26 Section 5 Taking a Range Only Measurement During Range Only Mode ballistic calculations are not applied and the unit can acquire most targets up to 2 000 yards Measurement results are presented as horizontal distance and include basic range with up down hill angle to target correction Range only is the default measurement mode When you power ON the G7 BR2 the last used measurement profile will be active For information about applying a ballistic profile to measurements see Section 7 page 31 The basic steps for taking a Range Only measurement 1 Look through the eyepiece and use the cross hair to aim to the target 2 Press and hold the button The Laser status indicator is displayed while the laser is ac tive The laser remains active for a maximum of 5 seconds while acquiring data about the target If the target is not acquired in the 5 second period release the button and repeat this step 3 Once the measurement is displayed release the button The measurement will remain displayed until you press any button or until the unit goes into Sleep Mode The h character in the Lower Display indicates that the horizontal distance result is displayed 4 Press either the button or button to view the Measured Values Menu See example on next page To take an
37. yed Starts the Edit Mode When editing a character or number advances to the next character or number Exits Set up Menu and returns to Measurement Mode For sub menus returns to previous menu Short Press Increments to the next target type page 16 Press and hold for 3 seconds Displays the System Setup Menu page 22 Measured Values Menu or Wind Compensation Menu Toggles to the other menu Wakes up instrument Exits the Profile Edit Mode While viewing measurement results returns to the Measurement Screen You must press the button a second time to initiate a new measurement 13 System Set up Menu and sub menus System Set up Menu and sub menus Measurement Mode Measurement Mode Edit Mode Edit Mode Sleep Mode Sleep Mode Scrolls to the previous menu option Scrolls to next menu option Enters the Wind Compensation Menu after calculating a ballistic solution Measured Values Menu or Wind Compensation Menu scrolls to the next option Measured Values Menu or Wind Compensation Menu scrolls to the previous option Enters the Wind Compensation Menu after calculating a ballistiv solution Scrolls to the next character or number The auto accelerating editor scrolls faster the longer the button is pressed Scrolls to the previous character or number The auto accelerating editor scrolls faster the longer the button is pressed Wakes up instrument Wakes up instrument
Download Pdf Manuals
Related Search
Related Contents
Worldwide Lighting W83126C16-AM Installation Guide L`essentiel de la séance de la SOP/Gagner du temps, 22 mars 2007 GENERAL Philips MULTIGROOM Series 7000 QG3378/15 ML88T 88Watt POWER PACK WARNING WARNING DR2-2013(c) SAGAv1.0 User_Guide 1 - digital XT420 Quickstart_D Scarica Standard du Commerce Equitable Fairtrade les graines et les fruits THIS PRODUCT IS FOR OUTDOOR USE ONLY Copyright © All rights reserved.