Powell “LYNN” Series - Precision Power Systems and Technology, Inc.
Contents
1. 3kW Power Supply 18
2. 5 will stop the heat cycle This is enabled when E S is set to EN This will not activate the shunt trip The front panel E STOP switch remains in circuit AUX A user defined trip can be wired between terminals 3 and 5 Enabled when E A is set to EN RESET Connecting terminal 4 to terminal 5 will issue a fault reset This is always enabled COMMON Not used 7 8 amp 9 are normally open relay connections with 10 being common for all relays HEAT ON Connected to COM when HEAT cycle is on FAULT Connected to COM when a FAULT occurs READY Connected to COM when the HEAT cycle is off and no faults exist COM Common connection for the relays The contacts for these relays are rated at 250V 3A 8 APPENDIX B Tuning examples The following examples are intended as a guideline for tuning the power supply only It is recommended that users add examples of their applications to this list as a reference future applications Coil Caps Fre Power Voltage Inverter 2098 EI Pape We a kHz kW Vins Current Nels 1 steel pipe 1 320 8 4 x 2 5 165 3 180 74 1 steel pipe 1 320 7 2 X 2 5 223 3 160 54 1 steel pipe 1 320 5 1 x 2 5 349 2 9 183 70 Open 1 320 8 5 x 3 4 308 3 230 44 1 steel pipe 1 320 3 3x 1 5 324 3 90 70 1 steel pipe 0 660 5 3 x 1 5 392 1 2 70 24 Frequency limit 1 steel pipe 0 210 10 8x4 256 2 3 500 65 Capacitor limit 2 x 1 2 stud 1 320 5 3 x 3 4 300 3 230 70
3. A OQO Figure 2 Front panel layout for model 3 135 400 3 4 1 Limit and trip indicators Identified by 1 in Figure 2 on page 9 Limit indicators These indicators are yellow in color and are lit when the heat station is not properly tuned The power output of the unit is limited below the desired level set by the power knob or remote pendant There are four limit indicators e POWER If lit the power is being limited at 3kW e VOLT If lit the capacitor voltage is being limited at 350V rms e FREQ If lit the circuit is being limited at the resonant frequency of the resonant tank o CURRENT If lit the inverter current is being limited at 70A peak Note The load coil current could be much higher than 70A peak 9 If any limit indicators are lit the heat station components needs to be adjusted to obtain the required power see section 6 1 on page 15 Trip indicators These indicators are red in color and are lit if the unit is tripped No power is being delivered to the load and the heat OFF indicator will be lit There are six trip indicators e FREQ The circuit momentarily operated below the resonant frequency due to a short in the load or heat station component or poor tuning of the heat station components e CURRENT The inverter current momentarily exceeded 70A due to a short in the load or heat station component of poor tuning of the heat station components DOOR Indicates that the cove
4. 11 A 0 Program DUON Said e a a os ct ts a a h e a at 11 4 11 Power Display Indicator a acatar aia dais 11 4 12 Start frequency adjustMent coccccnnnnnnccccncncccnncnnnnnnnnnnncnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnno 11 4 13 Feedback SelectiON oooononnncccccnnnnnncccncononccccnncnnnnnnnnnnnnnnnnncnnnnnnnnnnnnnn cnn nn nnnn nan erne 12 PROGRAMMING IN AUTO MODE cicoocicooiuosinonicaninancnoncnnacnanianacnani n ora nan ra cniniiada e enana 13 9 1 Enterng a PMsn 13 5 2 Running a program sarna eters ic cee eee A eee ELLE 14 5 3 Enabling external connections A aa cA Waa Aran Alea ia 14 LOAD STATION TUNING iisipin itinere intonato ei iedee ae een 15 AET alae A E E E 15 6 2 Changing the heat station components ccccccnnnnnccccconccinncnnnannncncnnnnnnnnnnnnnnnnnnnnnnnnnnn 16 APPENDIX A USER INTERFACE aA Een er rende 17 TAL Terminal Block ere i a0 ces tui ae er cunt en re ra ceeded ene es re an rar Pal re erne eet coticads 17 e PSI BI E A RE IO OR AA TT 17 APPENDIX B TUNING EXAMPLES iii 18 1 Specifications and features 1 1 Output Maximum Power 3kw Maximum Apparent Power 6 6kKVA 230V input Minimum Power Factor 0 50 230 V input Duty Cycle 100 Maximum Voltage 350V rms Frequency 135kHz to 400kHz Maximum Response Time 0 1s Minimum Allowed OFF Time 0 5s 1 2 Input AC line to line voltage 208V 240V 10 50 to 60Hz A
5. C line current 14 5A 230V AC power 3 6kKVA 1 3 Physical Dimensions Length 20 5in 521mm Width 11 7in 297mm Height 12 7in 823mm Weight 43 5lb 20kg 3kW is output power 3 6kVA input power allows for losses in the power supply Limited by rating of resonant capacitors 3 When using the adjustable start frequency feature 1 4 Front panel controls and indicators LED Indicators Yellow indicator for power limit Yellow indicator for voltage limit Yellow or red indicator dual color for inverter current limit or trip respectively Yellow or red indicator dual color for frequency limit or trip respectively Individual red indicators for door temperature flow and or auxiliary interlock trips Numeric Displays Run time read outs for output voltage inverter current and frequency Power Meter 0 100 Job number Auto mode Step Auto mode Step Time Auto mode Elapsed time Manual and Auto mode Controls Manual Mode Rocker switch for output power ON OFF Single turn knob for power level Manual mode Pushbutton to reset trips Rocker switch for manual or auto programmed operation Emergency stop button Freq button to select start frequency Controls Programmed Mode Program Job Step Freq Pwr Time Freq Clear and Enter buttons for programming automatic mode operation 1 5 Internal heat station Resonant capacitors
6. EXT position 3 Connections This section gives a description of the required steps to connect the load input voltage and what connections to make to run the unit remotely Output for mounting of heating coil Water input connection Water output connection Terminal Block 1 Terminal Block ff 2 Power cord for connection to supply voltage plug not supplied 006000 Figure 1 Terminal blocks circuit breaker load and input voltage connections 3 1 Load Mount the heating coil to the side of the unit see O in Figure 1 using four 10 32 non magnetic e g brass screws For most applications a water cooled coil is necessary If a flow switch is used in the water path it can be connected to Pins 4 amp 5 of Terminal Block 2 See Appendix A for more details 3 2 230VAC input voltage The unit is supplied with a 6 foot long cord see in Figure 1 Install a single phase grounded locking plug on the power cord Connect the plug to an appropriate supply voltage outlet socket Note the requirements of the supply voltage given in section 1 2 on page 3 Ensure that a proper safety ground is connected to the ground terminal of the three wire socket 3 3 Circuit Breaker The circuit breaker see amp in Figure 1 on page 7 is the is equipped with a shunt trip which will shut off the power if the cover is removed from the unit or if the E Stop switch is pressed 3 4 Terminal Block ff 1 The top
7. Induction Power Supplies 3kW 135 400kHz Integral Heat Station User s Guide Model 3 135 400 3W Rev E 12 1 04 Table of Contents SPECIFICATIONS AND FEATURES Museer erne ELLE EL EEE ri 3 A Oe 3 A A O 3 A A nate Scan tliat e A tah Schade Mae aa 3 1 4 Front panel controls and IMdICatOrS ciao 4 SA A Er tds cols ea ere Socata de aaeei 4 16 Proteccion ito rai aa 5 A Te Rica er ree re mer ERE a E ERE DE amr eae ENN 5 1B COOMMG NY ALCP sonora cht a e gaits atch re heheh hs e E rare E R Ene 5 GETTING STAR TED sii A A A E ENEA da Eca N aranana aAa Ai 6 2z Safety Wanda iia 6 A YI aia is ses cin seh Sate deter re gb be E Sai E E Sa eben E dnd am sepia eas soca 6 CONNECTIONS raices 7 A aa a a a a a a EDER ELIE ES SEE err BED RESENS BES wet eae ee ae SEES ED 7 See GU VAG Input voltage i asin i a a Raia IA 7 sds GIRGUIE Bs Er Cece re EA AA ind re eo re ued ease 8 32 Terminal Block asnicar 8 3 5 Fermina Block H 2rd aeoea a a aa ere 8 FRONT PANEL OPERATION LEE r aa sin Aea aras eaa diana caian 9 4 1 Limit and trip indicators a 9 4 2 Heat ON OFF indicators is 10 4 3 Program status indicators 0 A tence patentee eede hone teed oidten dt oogs 10 4 4 Voltage Current and Frequency Indicators ccccccnccccccccccnccccnncnnnanannconnnnncnananannnnnnnos 10 A dao oda 10 4 6 Heat SWIER ara ci 10 AT Ea ONL E EO E E E ciabatta te cle elt aoe 10 4 8 DIODE SWICK sara bereg daii a aaa 11 4 9 gt E STOP DUON minn N te ashe A
8. Two 660nF 350V capacitors supplied Series inductor Adjustable for load matching 1 6 Protection Power Limited to 3kW in any feedback configuration Inverter output current Limited to 70A peak Short circuit protected Resonant capacitor voltage Limited to 350V rms Line current 20A Circuit breaker Temperature and cooling Air cooling provide by three fans Heatsink temperature switch for protection Safety Interlocks Emergency stop button or door switch opens the main circuit breaker 1 7 Load Quality factor of load Will operate with any load Q including resistive loads provided that the output frequency and voltage is within the specifications 1 8 Cooling Water Maximum pressure 100PSI 690kPa Minimum differential pressure 30PSI 207kPa Minimum water flow 5GPM 0 3 Maximum inlet water temperature 105 F 41 C Minimum water resistivity 590Q in 1500Q cm Supply hose location Back of Cabinet 2 Getting started 2 1 Safety Warnings Have all operation maintenance and servicing performed by qualified personnel only il Read this operation manual completely before using the power supply 2 Induction heating can be dangerous Obey all warnings on unit and in manual 3 Do not touch live electrical parts In operation this means the output connectors the work coil the work piece and any bus work or cabling co
9. d on the PCB for constructing additional circuitry for auxiliary feedback If a 0 5V DC feedback signal can be provided it can be used directly See Appendix A for more information on connecting to the power supply The position of the jumper on JI ontrols the type of feedback that Is utilized by the power supply or regulation The Power position is standard 00 00 bno o O E Mm JA0J O O WoT Auto 1x0 Control Board ases Figure 3 Feedback jumper location 5 Programming in AUTO mode The power supply can be programmed 12 separate heating profiles or jobs Each profile can contain 25 steps The duration of each step can be up to 640 seconds 5 1 Entering a program 1 2 9 Turn on the power supply and put the MODE selector switch in MANUAL Enter the program mode by depressing the JOB button for 2 seconds until the Volt Curr and Freq displays go blank The STEP will read 1 and JOB will display the last job used or 1 if no other job was used If a heating profile has previously been entered in a Job then the power and step time will be displayed on the PWR and STEP TIME readouts To clear an existing program select the job to be cleared press the CLR button then press the ENT button twice once for JOB 2nd for Auto Repeat Ar A power level and a time can be entered for up to 25 steps The power level will ramp from the la
10. ency 6 1 Tuning This section provides the procedures required for the final tuning of the heat station for a specific heating coil and load It is assumed that the initial setup of the heat station has been completed as described in section 3 The aim of this exercise is to have the unit operating at full power of 3kW without any indicators lit 1 Ensure that the heat switch on the front panel is in the OFF position that the MODE selection switch is in the MAN manual position and that the power level knob is turned fully counter clockwise see Figure 2 on page 9 Turn on the circuit breaker The green STANDBY indicator should light up indicating that the unit is powered up Press the reset button if any red trip indicators are lit 2 Put the HEAT switch in the ON position e lf the unit is not delivering full power and the frequency is indicated as 135kHz no limit indicators will be lit the tank frequency is outside the range of the unit e If the current limit indicator lights up or a current trip occurs continue increasing the inductance of the series inductor e increase the turns of the inductor until the current limit indicator stops to light up at full power Increase the turns using the turn selector bar as described in section 6 2 1 on page 16 e lf the frequency limit indicator lights up or a frequency trip occurs continue decreasing the inductance of the series inductor i e decrease the turns of the induc
11. n the heating will be terminated While in AUTO mode the ON position initiates the heat cycle Putting the HEAT switch in the OFF position will terminate the heat cycle 4 7 Power Pot Identified by in Figure 2 on page 9 The power pot sets the requested power level as indicated by the POWER read out The level of power feedback is indicated by the percentage of the LED ring around the POWER POT that is illuminated This pot is disabled during AUTO mode operation 4 8 MODE switch Identified by Gin Figure 2 on page 9 In the manual position MAN the power supply turns on with the HEAT switch and power level is controlled by the POWER POT The programming the AUTO mode is done with the MODE switch in the MAN position In the automatic position AUTO the power supply runs programmed jobs The heat cycle is initiated with the HEAT switch and the power levels and duration of the cycle are controlled automatically as programmed 4 9 E Stop button Identified by in Figure 2 on page 9 Pressing the E Stop switch will stop a heat cycle and operate the shunt trip to open the circuit breaker 4 10 Program buttons Identified by in Figure 2 on page 9 The program buttons are used to program and display jobs for the power supply to run automatically See section 5 on page 13 for a description of how to program the power supply 4 11 Power Display Indicator Identified by 11 in Figure 2 on page 9 This read out displays the demand
12. n be used to change them For these parameters EN means Enable and DIS means Disable E H External Heat Disable The external heat control is not available and only controlled from the front panel Enable The heat cycle is started by connecting terminal 1 and 5 on Terminal Block 2 E S External Emergency Stop Disable The terminal block connection for E Stop is ignored Enable terminals 2 amp 5 must be connected for the power supply to operate When opened the heat cycle is terminated but the circuit breaker will not be opened by the shunt trip as it would by pressing the E Stop button E A External Auxiliary Trip Disable The terminal block connection for Auxiliary Trip is ignored Enable When terminals 3 amp 5 are not connected an Auxiliary Trip will display on the front panel and the unit will not operate Note that the RESET function terminal 4 amp 5 is always enabled There is no soft switch for this function ADR Address When the RS485 port is being used to control or monitor the power supply a unique ID for the machine can be entered 00 99 BR Baud Rate The communications baud rate for an RS485 connection can be set here 2 4 4 8 9 6 19 2 38 4 kbps 6 Load station tuning WARNING Make sure that the circuit breaker is turned off before adjusting heat station components This section describes the procedures for tuning the heat station so that full power will be obtained at the desired frequ
13. n repeat cycles and the TOTAL TIME will indicate the repeat number of cycles Press the TIME A W to increase or decrease the pause time Press the PWR A V to increase or decrease the number of repeat cycles Press ENT when completed Note When using any one JOB a time of more than 3 seconds must be entered at any STEP and a power level of more than 1 entered to avoid an AUX trip 5 3 Running a program 1 With the MODE selector in manual press JOB to enter program mode Press the JOB key to select the job you wish to run Press enter ENT 2 To view the job parameters before running the job press the STEP button will display the power and time for each step Put the MODE selector switch in the AUTO position Put the HEAT switch in the ON position to run the selected job To run a program with a momentary on signal such as a footswitch a On Terminal Block 2 connect the control common 5 with the relay common 10 b Connect terminal 1 with terminal 7 C Wire in the momentary closed contact to terminals 1 and 5 d Set E H external Heat to EN enable as explained in section 5 4 below oR 0 5 4 Enabling external connections The external connections on Terminal Block 2 can be enabled from the front panel controls Pressing the PROG button for 2 seconds will enter the parameter setting mode The step button can be used to cycle through the parameters and the TIME FREQ UP and DOWN buttons ca
14. nnecting them WARNING These symbols placed at the outputs of the power supply warn of the electric shock hazard there and RF burn hazard at the outputs when the unit is operating Disconnect input power before installing or servicing this unit The door interlock will open the breaker if the cover is removed However the input AC voltage is live at the top of the main circuit breaker 2 2 Set Up The following is a list of steps describing the required actions to get the power supply set up 1 Loosen the two quarter turn fasteners and remove the cover from the unit Check for any visual damage that could have happened during shipment Check all plug in connectors of PCBs Connect the heating coil to the output of the unit see section 3 1 on page 7 Read section 4 on page 9 to become familiar with the front panel controls N WARNING Make sure that the power is locked out before connecting AC power to the unit Connect only 208 240VAC 4 Ensure that the circuit breaker identified by gt in Figure 1 on the unit is in the OFF position Connect the power cord to a 230V single phase power source as described in section 3 2 on page 7 5 Perform the tuning of the heat station as described in section 6 1 on page 15 6 The unit is now ready for operation and can either be controlled by the front panel control selection switches in INT position or by external control selection switches in
15. power when the unit is in standby or program mode and displays the power output when the heat cycle is in progress 4 12 Start frequency adjustment The Power Supply starts at a frequency above 400kHz To generate power it lowers the frequency until the operating frequency is near yet still above the resonance point of the tank circuit If this resonant point it fairly low below 200kHz then it may take the power supply over one second to achieve power A start frequency adjustment is provided to allow the user to bring the start frequency closer to the operating frequency for quicker response times Depress the FREQ button for 3 seconds to enable the adjustment mode indicated by a brightening of the Frequency display At this point TIME FREQ A and W keys can be used to adjust the start frequency Press the enter ENT button and hold until the frequency lights dim The start frequency is now set WARNING Starting the power supply below the operating frequency of the tank circuit will result in a frequency trip and may damage the unit 4 13 Feedback selection The feedback used by the power supply can be selected by setting a jumper on the control PCB as shown by Figure 3 on page 12 The default is input power feedback right most position Output voltage auxiliary input and inverter output current can also be selected Due to the various forms of auxiliary feedback possible several options are provided An area is provide
16. r of the unit is not replaced TEMP Indicates that the temperature of the heatsink has exceeded 85 C FLOW Not used on the 3kW power supply AUX An auxiliary interlock wired to the unit has tripped it or the input AC voltage has dropped 4 2 Heat ON OFF indicators These LEDs show whether the power supply is generating output or is off identified by in Figure 2 on page 9 4 3 Program status indicators Identified by in Figure 2 on page 9 These read outs display the programs status when using the AUTO mode The STEP TIME indicator display minutes and the ELAPSED TIME indicator displays seconds during manual mode operation 4 4 Voltage Current and Frequency Indicators Identified by amp in Figure 2 on page 9 These read outs display the output voltage the inverter current and the operating frequency when the power supply is operating 4 5 Reset Button Identified by in Figure 2 on page 9 This button is used to clear the fault indicators if a run time or interlock trip has occurred Depressing the button will light the limit and trip indicators and clear the latch for the fault indicator If the LED does not go out then the reason for the fault is still present 4 6 Heat switch Identified by Figure 2 on page 9 When the power supply is energized and no fault indicators are lit putting this switch in the ON I position will start the power supply delivering heat When moved back to the OFF O positio
17. selector bar 0 11 turns O Variable shorting bar Figure 4 Adjusting the Series Inductor 7 APPENDIX A User Interface 7 1 Terminal Block 1 1 10V reference This a 10V reference voltage for available for connecting to a potentiometer remotely Terminal 1 to top of the pot terminal 2 to the wiper and terminal 3 ground to the bottom of the pot Remote Power Reference When SW301 the INT EXT switch is set to EXT the voltage level at this terminal controls the command reference O volts is minimum and 10 volts is maximum A PLC can be connected to terminal 2 with its reference to terminal 3 Reference Ground Used with terminals 1 amp 2 the ground for the power reference AFBK Auxiliary Feed Back not currently active Common for AFBK Flow by shorting to common can be used to disable internal pressure switch Common for Flow This is an RS485 Port Itis configured to be asynchronous half duplex with an 8 bit 1 stop bit format This is a dedicated protocol The baud rate is selectable to from 2400 baud to 38400 baud Terminal A of the RS 485 port Terminal B of the RS 485 port Common for the RS 485 port 7 2 Terminal Block 2 See section 5 4 on page 14 for more information on enabling these connections 1 10 START STOP Connecting terminal 1 to terminal 5 will start the unit This is enabled when E H is set to EN and the HEAT switch is ON E STOP Opening a connection between terminal 2 and terminal
18. st power level to the power level requested To get a power level quickly set the time to 0 1 seconds and then set power to the desired level Then set the next step to that power level and the time to the desired interval For each step press PWR UP A and the PWR DOWN W keys to set the power level and press TIME FREQ UP A and the TIME FREQ DOWN keys to enter a time up to 640 seconds For longer intervals several steps in a row can be set to the same power level Press STEP to move to step 2 Enter power level and time as in step six Press ENT enter once this will bring you to the Ar display explained later press ENT again to record changes or press JOB to move onto the next job Note If no Job has been programmed an AUX trip indicator will be lit Pressing the CLR button will exit program mode without saving changes Note Waiting too long to enter values unit will time out and exit programming 5 2 Auto Repeat Function 1 2 DO Each JOB except JOB 0 has an auto repeat function which enables a selected job to be repeated up to 999 times To activate auto repeat press and hold JOB for more than one second after selecting the job you want to repeat press ENT once this will open the auto repeat function In the STEP window Ar will appear in STEP TIME and in TOTAL TIME window 0 s will appear The step time will indicate the pause time indicated by a P in the STEP window betwee
19. three terminals of Terminal Block ff 1 can be utilized for remote power reference see in Figure 1 on page 7 The lower three terminals can be used to interface the power supply with a computer APPENDIX A User Interface on page 17 explains the connections in more detail 3 5 Terminal Block ff 2 Heat On E Stop Auxiliary Interlock and Reset functions can be run remotely from this terminal block There are also relay contacts for Heat On Power Supply Fault and Power Supply ready APPENDIX A User Interface on page 17 explains the connections in more detail 4 Front panel operation This section identifies and describes the various parts of the front panel 47 r bo LIMIT FAULT HEAT PROGRAM PWR VOLT CURR FREQ DOOR TEMP FLOW AUX ON STANDBY 1 O PROG FREQ 3 gt m JOB ELAPSED TIME VOLT POWER j 7 7 JOB STEP bb G DL J Vs Fo 3 STEP STEP TIME CURR A TIME A PWR FREQ 4 lg FREQ KHZ 777 CLR ENT es eee EMERGENCY ON STANDBY MANU AUTO f RESET ed HEAT A STOP i MODE 9 5 7 SE oO Limit and trip LED Heat On Off LEDs Program Indicators Volt Curr and Freq Indicators Reset button Heat switch NES Power Knob Mode Switch E Stop Switch Program Buttons Power Indicator 00 Y
20. tor until the frequency limit indicator stops to light up at full power Decrease the turns in small increments by using the shorting bar as described in 6 2 1 on page 16 3 Increasing the series inductance until the current reading is around 50 at full power will optimize the efficiency of the system This will act to protect the transformer and capacitors from overheating Highly recommended 6 2 Changing the heat station components This section describes the procedures for changing the heat station components 6 2 1 Series inductor The turn selector bar is identified by in Figure 4 on page 16 The near position selects zero turns and the far position eleven turns as indicated in Figure 4 on page 16 Tighten the bar into position using the mounting screws The shorting bar has to be used for finer adjustment of the series inductance during the tuning section 6 1 on page 15 of the heat station Example If the initial setup was for 4 turns shorting bar not installed and the turns needs to be decreased with a quarter turn install the shorting bar in the low 3 position If the shorting bar reaches the high 1 position and the inductance still needs to be decreased remove the shorting bar completely and move the turns bar one position forward e g from the 4 turns position to the 3 turns position WARNING Make sure that the circuit breaker is turned off before adjusting heat station components O Turn
Download Pdf Manuals
Related Search
Related Contents
Tri-M Systems FV-25 User's Manual M A N U A L E Philips Saeco Via Venezia Sony PCGA-DDRW2 User's Manual Manuel d`installation d`un proxy Sony AC-UD20 Operating Instructions Tecumseh RGA5512BAA Performance Data Sheet MANUAL DE INSTRUCCIONES HATSAN Samsung NQ50H5537KB Manuel de l'utilisateur Copyright © All rights reserved.