1. ON position NOTE When the circuit breaker trips the switch reverts back to the OFF position No power to the heating element Ensure the thermal overheat switch located on the right end of the heating element under the protective cover is not tripped Access the switch by removing the two screws on the right side of the oven body and lifting the cover off If the thermal overheat switch is tripped reset it by pressing the white button in the center of the switch see photo below d CURE OVEN USER S GUIDE Domaille Engineering LLC Service amp Support Technical Specifications Machine Height 6 inches 152 mm Machine Width 8 25 inches 210 mm Machine Length 21 00 inches 533 mm Power Requirements 1 2 amps 220 240VAC 50 60 Hz Machine Weight 16 5 lbs 7 48 ke Shipping Weight 19 0 lbs 8 61 kg Environmental Operating Specifications Altitude up to 2000m Temperature 5 40 C Humidity 40 80 Voltage Fluctuation 10 Voltage Transients to 2500V Pollution Degree 2 or as restricted or extended conditions apply In the event of malfunction or when other maintenance is required beyond the steps documented in this manual service must be done by a qualified Domaille Engineering technician There are no user serviceable parts inside the machine Do not remove sealed screws Evidence of tampering will void warranty For assistance contact Domaille Engineering LLC USA CE Not
2. the timer cycle start button item 12 The Timer LCD Readout item 8 will now turn green and begin to count down from the cycle time set point and the Temperature LCD Readout item 6 will gradually increase to the oven temperature set point When the cycle time has expired power to the heating element will automatically shut off and the oven will gradually return to ambient temperature NOTE Depressing the Timer Cycle Start Button item 12 during the cycle will restart the timing cycle from the beginning Operation of the oven may be stopped by depressing the Timer Reset Button item 11 at any time during the cycle d CURE OVEN USER S GUIDE Domaille Engineering LLC Curing Oven Operation Temperature Hold Mode Select the TEMPERATURE HOLD mode with the Operation Mode Selector Switch item 1 This disables the timer and allows the curing oven heat plate to reach the temperature set point and hold constant at that setting until power to the curing oven is manually shut off at the power ON OFF switch circuit breaker item 13 located on the back panel of the unit NOTE The heating element is automatically activated when the TEMPERATURE HOLD mode is selected Set the desired curing temperature Press the Temperature Readout Switching Button item 3 until the Tem perature Set Point Indicator item 4 illuminates The Temperature LCD Readout item 6 will now display the current heat
3. ION This oven is hot during operation and retains heat for some time after turning off Always use oven mitts when handling hot materials and al low metal parts to cool before cleaning Position the oven so that it is never against a wall or in a corner When operating the oven on a work surface keep the surrounding areas clear and free from clutter Ensure adequate air space surrounding the oven for circulation Do not place anything on top of the oven while it is operating or while it is hot Do not operate this oven with other major equipment plugged into the same power socket there is a risk of blowing the fuse Do not touch the hot oven surfaces while the unit is on or while cool ing All users of this oven must read and understand this User s Manual before operating this equipment If the oven begins to malfunction during use immediately unplug the cord Do not use or attempt to repair the malfunctioning oven Do not leave oven unattended during use d CURE OVEN USER S GUIDE Domaille Engineering LLC Welcome Congratulations on selecting the Domaille Engineering Ferrule Cure Oven This User s Guide will assist you with the operation and maintenance of the Cure Oven to maximize the use and life of this precision equipment Introduction The Domaille Engineering Ferrule Curing Oven is specifically designed for curing twenty four 24 MT and MT RJ type ferrules at a time but can also a
4. ITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR JURISDICTION TO JURISDICTION 12 Company Information Domaille Engineering LLC is an precision manufacturer distinguished by the accuracy of our products and services One of our critical goals is to provide excellent customer service Please contact us for service support or input on how we can improve our service to you Domaille Engineering LLC 7100 Dresser Drive NE Rochester MN 55906 507 281 0275 www DomailleEngineering com Q Domaille Engineering LLC Domaille Engineering LLC 7100 Dresser Drive NE Rochester MN 55906 Phone 507 281 0275 s Fax 507 281 5694 www DomailleEngineering com
5. Q Domaille Engineering LLC FERRULE CURING OVEN MODEL CO 6600 USER S GUIDE Domaille Engineering LLC 7100 Dresser Drive NE Rochester MN 55906 Phone 507 281 0275 Fax 507 281 5694 www DomailleEngineering com TABLE OF CONTENTS SE T 1 Iola cere O mney re A E E O E E T 3 Dooa e E a eee re one E ee ee eer 4 Grice iirc cl Bro chico cee een ter ore enter er en err een ee eee er eee 5 iio esas lel ia 0 errr eter H nce neem pe erre ar 7 REN al rath al ef cara ele REPA ieni inn Eaa rrr ore 10 We CHCA e CICA MONG aioir ireo EE EEEE Ea 11 E P E A E A E E OE 11 e N E E E E OA 2 Company Morna O soran r en ETSEAN EREDE ETE E A d CURE OVEN USER S GUIDE Domaille Engineering LLC Important Safeguards Before using this electrical equipment the following basic precautions should always be followed 1 Read all instructions 2 Keep oven out of reach of children 3 Before use check that the voltage of wall outlet corresponds to the one shown on the rating 4 Do not operate equipment with a damaged cord or plug or after the oven malfunctions is dropped or damaged in any manner Return oven to the nearest authorized service center in order to avoid a hazard 5 Do not let cord hang over the edge of table or hot surface 6 Do not immerse plug cord or oven into water due to risk of electric shock 7 This oven is not intended for use by persons including children with reduced physical sens
6. ccommo date with the addition of a single fiber connector curing block available separate ly any of the popular single fiber connector designs including FC SC ST and LC The oven holds up to forty eight 48 connectors in a neatly organized fash ion Temperature and time controls are conveniently located on the front panel allow ing for easy operation The oven allows for two modes of curing operation timer mode and temperature hold mode The timer mode allows the oven to gradually increase to a selected temperature maintain the temperature for a selected operating time and then gradually de crease to room temperature by shutting off power to the heating element The temperature hold mode maintains the curing oven at a constant selected tem perature indefinitely The desired mode is selected from the front panel making set up simple The oven can be ordered in either 120 volt Model CO 6500 or 240 volt Model CO 6600 Domaille Engineering LLC CURE OVEN USER S GUIDE Overview CAUTION DO NOT USE THIS PRODUCT IN ENVIRONMENTS WHERE FLAMMABLE OR EXPLOSIVE GASSES MAY BE PRESENT Operating Environment Do not subject the unit to the following conditions 6 Dramatic temperature fluctuations High humidity or condensation Water oil chemicals or corrosive gasses Dusty environments Severe shock or vibration Z Z Z Improperly grounded electrical outlets Operating Location The unit should be placed
7. controller set point CAUTION THE CURING OVEN TEMPERATURE SET POINT MUST NEVER EXCEED 140 C TEMPERATURES ABOVE 140 C WILL TRIP THE OVERHEAT THERMOSTAT SHUTTING OFF POWER TO THE HEATING ELEMENT Use the Temperature Set Point UP and DOWN Buttons item 2 to select the desired temperature set point Press the Temperature Readout Switching Button item 3 until no mode indicators are illuminated The Temperature LCD Readout will now display the current curing oven heat plate or heater block temperature NOTE Re selecting TIMER MODE will also shut off power to the heating element d CURE OVEN USER S GUIDE Domaille Engineering LLC Maintenance and Repair Maintenance of internal electrical parts is not required Do not disassemble modi fy or attempt to repair the product All repair work must be done by Domaille Engineering at our Rochester MN location Any attempt to modify or repair the unit will void all warranties either express or implied Simple Troubleshooting Simple troubleshooting of the oven for common minor problems 15 possible by using the following guide No power to the curing oven Ensure the power cord is securely attached to both the power supply wall outlet and the curing oven Power Cord Outlet item 14 located on the back panel of the unit Ensure the curing oven Power ON OFF Switch Circuit Breaker item 13 located on the back panel of the unit is in the
8. ial Authorization Number RMA You must ship the products back to Domaille in their original ot equivalent packaging pre pay shipping charges and insure the shipment or accept the risk of loss or damage during shipment Along with your RMA in clude your name telephone number return address proof of original purchase date and a description of the claimed defect If the defect is covered by this lim ited warranty Domaille will repair or replace at its option the product or the defective component part s and ship them freight prepaid to an address in the continental U S Shipments to locations outside of the U S that are not the origi nal shipped to location will be made freight collect or will be shipped to the origi nal shipped to location at the discretion of Domaille NO WARRANTY OTHER THAN THE ABOVE LIMITED WARRANTY IS MADE EITHER EXPRESS OR IMPLIED ALL EXPRESS AND IMPLIED WARRANTIES FOR THE PRODUCT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FIT NESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE ONE YEAR LIMITED WARRANTY PERIOD DOMAILLE SHALL HAVE NO LIABILITY FOR ANY INCIDENTAL OR CONSE QUENTIAL DAMAGES RELATING TO ITS PRODUCTS SOME STATES OR JURISDICTIONS DO NOT ALLOW LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES OR EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR CERTAIN PURCHASERS SO THE ABOVE LIMITATIONS OR EXCLU SIONS MAY NOT APPLY TO YOU THIS LIM
9. ice European Union Marking by the symbol CE indicates compliance of the Ferrule Cure Oven Model 6600 to the following directives of the European Union 2004 108 EEC EMC Directive EN 61010 1 2001 EN 61010 2 010 2003 EN 61326 1 2006 EN55011 2009 A1 2010 Year of CE Marking 2013 EMC test report T V SUD report NC1212577 1 Safety test report T V SUD report 092 1212560 000 11 d CURE OVEN USER S GUIDE Domaille Engineering LLC LIMITED WARRANTY Domaille Engineering LLC Domaille products are warranted by Domaille to be free from defects in workmanship and materials for a period of one year from the original purchase date This warranty covers defects in materials or workman ship only and does not include damage due to abuse misuse problems with elec trical power problems with compressed air supply servicing not authorized by Domaille failure to properly care for and maintain the products or normal wear and tear In addition use of parts components or accessories not supplied or approved by Domaille will void this warranty Domaille s sole liability arising from any use of its products and this warranty is limited to repair or at Domaille s sole discretion replacement of defective prod ucts or defective component parts thereof To request warranty service you must contact Domaille at 7100 Dresser Dr N E Rochester MN 55906 USA If war ranty service is required Domaille will issue a Return Mater
10. n when cycling 9 Timer Set Point LCD Readout 10 Timer Set Point Adjustment Buttons minutes seconds 11 Timer Reset Button 12 Timer Cycle Start Button 13 Power ON OFF Switch Circuit Breaker 14 Power Cord Outlet d CURE OVEN USER S GUIDE Domaille Engineering LLC Cure Oven Set up Place the curing oven on a hard flat surface that is sturdy enough to support the weight of the oven jumpers and any accessories A lab table or workbench is recommended Connect the curing oven to the power supply Attach the female end of the supplied power cord to the curing oven power cord outlet item 14 located on the back panel of the unit Attach the male end of the supplied power cord to the power supply wall outlet WARNING TO PROVIDE PROTECTION AGAINST RISK OF ELEC TRIC SHOCK CONNECT ONLY TO A PROPERLY GROUNDED OUTLET Turn the curing oven power ON OFF switch circuit breaker item 13 located on the back panel of the unit to the ON position Curing Oven Operation Timer Mode Select the TIMER MODE with the Operation Mode Selector Switch item 1 This enables the timer and allows the operator to start the curing cycle when the oven is filled Power to the heating element will automatically shut off at the conclusion of the set cycle time Set the desired curing temperature Press the Temperature Readout Switching Button item 3 until the Tem perature Set Poin
11. on a hard flat surface that is sturdy enough to support the weight of the oven jumpers and any accessories A lab table or workbench is recommended Proper handling must be maintained in order for the unit to operate correctly Do not drop the unit Do not shake the unit Always ship the unit in the original shipping carton using the original packing materials Cleaning The oven exterior may be cleaned using a slightly dampened cloth and a gentle cleaner The temperature controller and timer should never be exposed to such items as paint thinners benzene compounds or strong acids or alkalines If cured epoxy builds up on the oven heat plate or heater block it may be re moved by gently scraping the block with an Exacto knife or similar tool d Domaille Engineering LLC Cure Oven Controls Ee Domaille Engineering f MN USA www DomailleEngineering com CURE OVEN USER S GUIDE 1 2 3 d Domaille Engineering LLC CURE OVEN USER S GUIDE Cure Oven Controls Item Number Description Operation Mode Selector Switch Temperature Set Point UP and DOWN Buttons Temperature Readout Switching Button current temperature or set point 4 Temperature Set Point Indicator 5 Temperature Deviation Indicators above or below set point 6 Temperature LCD Readout current temperature or set point 7 Heat Controller Output Indicator 8 Timer LCD Readout turns gree
12. ory or mental capabilities or lack of experience and knowledge unless they have been proper training by a person responsible for their safety 8 Always wear protective insulated oven mitts or gloves when removing ferrules ot handling the unit THE OVEN GETS VERY HOT 9 Do not touch hot surfaces 10 Place ferrules or connectors in the oven before setting the timer or heating the oven 11 Do not operate the oven for any other purpose than its intended use 12 Always move Power button to OFF position before removing the plug from the wall outlet 13 Do not place paper cardboard plastic or other flammable materials inside the oven 14 Unplug from main power socket when not in use 15 Servicing and repair should only be conducted by an authorized technician 16 If oven is used in any manner not specified in this manual the protection provided by the equipment may be impaired d Domaille Engineering LLC CURE OVEN USER S GUIDE Important Safeguards CAUTION DO NOT USE THIS PRODUCT IN ENVIRONMENTS WHERE FLAMMABLE OR EXPLOSIVE GASSES MAY BE PRESENT WARNING ACCESS TO THE POWER SWITCH AND PLUG SHOULD BE MAINTAINED FOR EMERGENCY DISCONNECT WARNING CAUTION HOT SURFACES This oven gener ates high temperatures during use Proper precautions must be taken to prevent the risk of burns fires or other injury to persons or damage to property WARNING OVEN CORD MUST BE ROUTED AWAY FROM ALL HOT SURFACES CAUT
13. t Indicator item 4 illuminates The Temperature LCD Readout item 6 will now display the current heat controller set point CAUTION THE CURING OVEN TEMPERATURE SET POINT MUST NEVER EXCEED 140 C TEMPERATURES ABOVE 140 C WILL TRIP THE OVERHEAT THERMOSTAT SHUTTING OFF POWER TO THE HEATING ELEMENT d CURE OVEN USER S GUIDE Domaille Engineering LLC Use the Temperature Set Point UP and DOWN Buttons item 2 to select the desired temperature set point Press the Temperature Readout Switching Button item 3 until no mode indicators are illuminated The Temperature LCD Readout item 6 will now display the current curing oven heat plate or heater block tempera ture Set the desired cycle time The cycle time is displayed in the Timer Set Point LCD Readout item 9 Using Timer Set Point Adjustment Buttons item 10 numbers 3 and 4 set the desired number of cycle minutes Button 3 selects the ones digit and button 4 selects the tens digit Using Timer Set Point Adjustment Buttons item 10 numbers 1 and 2 set the desired number of cycle seconds Button 1 selects the ones digit and button 2 selects the tens digit NOTE Pressing the top of the button increases the unit value pressing the bottom of the button decreases the unit value Start the temperature cycle Ensure the temperature mode selector switch is set to TIMER MODE Depress