Home

20151124 ~ FORBO-EUROCOL-NL ~ 022-euroblock-one-coat

image

Contents

1. eurocol the strong connection nil is eurocol 022 EUROBLOCK ONE COAT Two Component Epoxy Surface DPM Product Typification Basis Component A Epoxy Coating 7 6 kg Component B Epoxy Curing Agent 2 4 kg Colour Component A Dark Grey Component B Off white Consistency Thin liquid Cost effective single coat application Allows the early installation of resilient floorcoverings British Standard 8203 British Standard 5325 compliant Suitable for use with underfloor heating systems Pinhole resistant Low viscosity and easy to apply Performances Specific weight Part A 7 6 Kg 4 2Lt SG 1 80 gr ltr Part B 2 4 Kg 2 3Lt SG 1 03 gr ltr Consumption Application Moisture vapour contents of up to 98 RH can be accommodated Depending on the moisture content of the base different thicknesses can be applied Can be used where a damp proof membrane is not present or if it is deemed ineffective Adheres to a variety of damp substrates even at low temperatures Suitable for sealing cracks and seams in subfloors Can be used in conjunction with under floor heating systems Moisture Testing Moisture testing should be undertaken in accordance with British Standard 8203 Working Process Layer thickness 24 m2 250 microns thickness Moisture Content Below 92 RH 20 m2 350 microns thickness Moisture Content up to 98 RH Storage Store in dry conditions between 5 C and 30 C Tool
2. 40 70 Directions for use e Add the epoxy curing agent part B to the resin coating part A and thoroughly mix together with a mixing spindle Eurocol no 855 in a slow speed drill until a uniform colour and consistency has been reached e Itis important to mix both components together for at least 4 5 minutes e Apply the mixed material immediately with a 2 mm x 5 mm V notched flooring grade trowel Whilst the product is still wet flatten out the serration ridges with a long handled fluff free paint roller that has been pre wetted with the mixed solution Itis essential that the applied coating is continuous free of pinholes and any thin patches Should issues be observed patch like repairs will be necessary In order to ensure that excess moisture vapour will not permeate the membrane the products must not be less than 250 or 350 microns in thickness For specific information please read Technical Facts above e Allow to cure for 8 to 11 hours at 15 C Once cured the surface of the 022 Euroblock One Coat should be primed with 044 Europrimer Multi and allow to dry as per the products data sheet e Once sufficiently dry apply a suitable Eurocol smoothing levelling underlayment to a minimum thickness of 3mm and allow to dry as per the products data sheet e Secure the floorcovering with the approved Eurocol adhesive Precautions 022 Euroblock One Coat can be irritating to the eyes respiratory system and skin
3. and may cause sensitisation by contact Consult the relevant health and safety data sheets for full information In case of accidents seek medical advice Application Notes The aforementioned systems are given as general guidance only Please consult one of Forbo Eurocol s Commercial Technical Advisors who will be more than happy to submit a tailor made written specification Environment and health Hazard Class Component A Xi irritant N dangerous for the environment Component B C corrosive Safety and environment Safety data sheets of Forbo Eurocol products according to EEG guideline 91 155 MSDS Available on request Articles Article Definition Packaging EAN code 022 Epoxy Coating Comp A 7 6 kg Eurocol is part of the Forbo Group RADO eurocol 022 Epoxy Curing Agent Comp B 2 4 kg the strong connection Eurocol is part of the Forbo Group RADO
4. s 2mmx5mm V notched flooring grade trowel Long handle fluff free paint roller Drying 20 C 5 to 6 hours 15 C 8 to 11 hours 10 C 14 to 20 hours Shelf Life 6 months in unopened packaging Potlife 20 C 1 hour en 25 minutes 15 C 2 hours 10 C 2 hours en 30 minutes Application 20 C to 80 C temperature Eurocol is part of the Forbo Group RADO eurocol The mentioned values have been established in our laboratory and must be considered as guidelines in view of possible variations in climatic circumstances subfloor compositions and layer thickness the strong connection Substrate e The subfloor must have a good tensile and compression strength and be smooth clean even permanently dry and be free from any contaminant deemed liable to impede adhesion and be in accordance with the requirements set out within the BS 8203 the BS 5325 BS 8204 and the DIN 18365 e Subfloors such as power floated concrete and sand cement screeds should first be mechanically cleaned to provide an adequate key We recommend shot blasting grinding or machine scarifying e The moisture content of the base must not exceed 98 RH Should doubt exist regarding the products use or its application always seek our technical advice User manual Working conditions Required surrounding temperature S415 29 C Temperature for material and subfloor min 15 max 20 C Relative humidity

Download Pdf Manuals

image

Related Search

Related Contents

Samsung HL-S7178W Manuel de l'utilisateur  Epson 1980WU  Guide d`utilisation des planches photographiques des choix visuels  Descargar Manual del Usuario  NEC 78K/0 Series User's Manual  Procedimiento para la Integración con CAS v1.0  AIRBLOK BD, DR AIRBLOK .../SD Inverter  INVITATION FOR BID T054087 INTELLIGENT    Samsung Galaxy S3 Neo Bruksanvisning  

Copyright © All rights reserved.
Failed to retrieve file