1. b Straight Acuminate Ground Collar applicable to measurement of test point that is close to the ground point Curved Acuminate Ground Collar applicable to measurement of test point that is relatively far from the ground point Straight Dentiform Ground Collar applicable to measurement of chip pin test point that is close to the ground point Curved Dentiform Ground Collar applicable to measurement of chip pin test point that is relatively far from the ground point User s Guide for RP7000 Series Active Probe 9 RIGOL Figure 5 Probe Tip T Figure 6 a Figure 6 b Straight Acuminate Ground Collar Curved Acuminate Ground Collar U Figure 6 c Figure 6 d Straight Dentiform Ground Collar Curved Dentiform Ground Collar 10 User s Guide for RP7000 Series Active Probe RIGOL 2 Solder in Probe Head Solder in probe head includes two types solder in differential probe head and solder in single ended probe head as shown in Figure 7 and Figure 8 Wherein solder in differential probe head is suitable for measurement of high density IC pin signals Nickel Wire an Se ass figure 7 Solder in Differential Probe Head Nickel Wire ASE ered ark Sleeve of Negative Pole Figur 8 Solder in Single ended Probe Head When using the solder in probe head for measurement please use auxiliary device to fix the probe head
2. Note to ensure the calibration precision the probe tips must be firmly connected to the calibration board during the calibration Note Relative specifications of the RP7000 series active probe depend on the calibration operation After the calibration is finished the DC gain offset voltage zero and offset gain will be calibrated User can query the information about the manufacturer model serial number and the last calibration time of the probe through CH1 gt Probe gt Probe Info User s Guide for RP7000 Series Active Probe 23 RIGOL General Care and Cleaning General Care Do not place the probe and its accessories in places where they will be exposed to sun light for long periods of time CAUTION Keep the probe and its accessories away from any corrosive liquid Cleaning Clean the probe and its accessories regularly according to their operation conditions using the method below 1 Disconnect the probe from the oscilloscope or voltage source 2 Remove the loose dust on the exterior of the probe and its accessories using a lint free cloth with mild detergent or water WARNING Make sure the probe is completely dry before using it to avoid short circuit and personal injuries 24 User s Guide for RP7000 Series Active Probe RIGOL Warranty RIGOL warrants that its products mainframe and accessories will be free from defects in materials and workmanship within the warranty period If a produ
3. the oscilloscope how to use the probe head how to replace probe accessories how to adjust the offset voltage how to calibrate the probe etc General Care and Cleaning Warranty Specifications User s Guide for RP7000 Series Active Probe III RIGOL Contents Guaranty and Declaration ssssssssssssssssssssssssssssssssssssssrerererererere ereer l Safety Terms and SymMbolS ssssssssssssssssssssssssssssssssssssssssere ereer rees lI Document Overview sss sss ss ss ss ss sss sss ss s s sss sss sss sss nnmnnn nnmnnn nnmnnn nnna Wl RP7000 Series Overview sss sss sss sss sss sss sss ss ss sss ss essen ense e reeeo en 1 Probe l Ntroductlo nine senan badagery Hd aye a N a A 2 General Inspection 0 ee eee ereenn 3 Probe DIMENSIONS tenion ata ke a een baci 4 Accessories and OPtiONS sese esse eree ereenn 5 Active Probe Amper sss sese ee eree ereenn 7 Probe Head niiina Sse tiene ott tae een ata 8 To Use RP7000 Series Active Probe sss ss sss sss sss sss ssssssssssssssssssssses 12 To Connect to the OsScilloscope sese eee eee eee eee 13 To Use the Probe Head aaezi aT TTT H TTT HT 15 To Replace Probe Accessories eee eee eee 19 To Adjust Offset Voltage siminn a a 21 To Calibrate the Probe sss esse sese 22 General Care and Cleaning sss sssssveve seve ne 24 Wa Tu T ST 25 Specifications 0 ese sees 26 IV User s Guide for RP7000 Series Active Probe RIGOL RP
4. 0204 1 Hand held Single ended Probe Head RP7 0205 1 0 2mm Nickel Wire RP7 0306 1 Trim Gauge RP7 0307 1 91Q Probe Tip RP7 0405 8 Straight Acuminate Ground Collar RP7 0501 2 Curved Acuminate Ground Collar RP7 0502 2 Straight Dentiform Ground Collar RP7 0503 2 Curved Dentiform Ground Collar RP7 0504 2 Marker Rings Yellow Pink Light Blue Dark Blue RP 0203 8 User s Guide RP7 0601 1 Probe Bag RP7 0602 1 Storage Box RP7 0603 1 Note the accessories listed in this section are only for reference the actual product is the standard 6 User s Guide for RP7000 Series Active Probe RIGOL Active Probe Amplifier The active probe amplifier Figure 2 with more than 1 5GHz bandwidth is a main component of the active probe One end of the active probe amplifier can be connected to the DS6000 series oscilloscope and the other end can be o inm l S amm a hL Pos Neg Marker mmr Figure 2 Active Probe Amplifier When connecting a probe head to an active probe amplifier push it straight in For single ended probe when connecting them pay attention to their polarities If the polarity is reversed the performance of the active probe would reduce and the active probe might even be damaged CAUTI ON AN There are Pos Neg markers on the hand held single ended probe head and black mark sleeve on the negative pole of the solder in single ended probe head User s Guide for RP7000 Series
5. Figure 10 Hand held Single ended Probe Head 16 User s Guide for RP7000 Series Active Probe RIGOL Hand held single ended probe head RP7 0205 91Q probe tip RP7 0405 Straight acuminate ground collar rotating the ground collar adjusts the spacing 0mm to 5mm between the ground collar and probe tip RP7 0501 O CAUTI ON Ground the ground collar when using the hand held single ended probe 3 Solder in Differential Probe Head The solder in differential probe head provides an effective bandwidth of more than 1 5GHz and its replaceable nickel wire enhance the usability of the probe and prolong its service life The structure of the solder in differential probe head is as shown in Figure 11 Figure 11 Solder in Differential Probe Head User s Guide for RP7000 Series Active Probe 17 RIGOL _ Solder in differential probe head RP7 0201 0 2mm Nickel Wire RP7 0306 When the points to be tested are widely spaced the length of the nickel wire will be increased At this point overshoot and ringing will occurs and the high frequency response will changes 4 Solder in Single ended Probe Head The solder in single ended probe head provides an effective bandwidth of more than 1 5GHz and its replaceable nickel wire enhance the usability of the probe and prolong its service life The structure of the solder in single ended probe head is as shown in Figure 12 The
6. before calibration after calibration before calibration lt 1 of current range after calibration 45mVpp 7ns 30V Peak CAT gt 8kV 26 User s Guide for RP7000 Series Active Probe RIGOL General Characteristics Environmental Operating Non operating Conditions Temperature 5 C to 40 C 40 C to 70 C Humidity 0 RH to 80 RH 0 RH to 90 RH Altitude 4600m 15300m Power Consumption 1 2W N A Weights 147g 10g 3 _ 530g 50g 4 Wire Length 1 4m 1 Typical value The specifications would change when different scales are selected 2 CAT I and CAT II Definitions Installation Category Overvoltage Category signal level special equipment or parts of equipment telecommunication electronic etc with smaller transient voltages than installation category Overvoltage Category II Installation Category Overvoltage Category II local level appliance portable equipment etc with smaller transient voltages than installation category Overvoltage Category III 3 The weight of the probe with the hand held differential probe head 4 The weight of the RP7000 series Active Probe Kit with the probe bag User s Guide for RP7000 Series Active Probe 27
7. between the two probe tips can be precisely adjusted by turning the roller and the replaceable probe tips prolong the service life of the probe The hand held differential probe head can be used to measure differential and single ended signals During the measurement you can turn the roller on the probe head to adjust the spacing between the probe tips so as to fit measurements with different spacing requirements The structure of the hand held differential probe head is as shown in Figure 9 Figure 9 Hand held Differential Probe Head User s Guide for RP7000 Series Active Probe 15 RIGOL _ Turning the roller to adjust the spacing 0mm to 5 5mm between the two probe tips Hand held differential probe head RP7 0204 910 probe tip RP7 0405 2 Hand held Single ended Probe Head The hand held single ended probe head provides an effective bandwidth of more than 1 5GHz Besides the spacing between the single ended ground collar and probe tip can be adjusted by rotating the ground collar and the replaceable probe tip and single ended ground collar prolong the service life of the probe The hand held single ended probe head can be used to measure single ended signal During the measurement the single ended ground collar must be grounded Pay attention to their polarities when connecting the probe head and active probe amplifier The structure of the hand held single ended probe head is as shown in Figure 10
8. pin on the same side with the negative pole mark sleeve refer to Figure 8 is negative Figure 12 Solder in Single ended Probe Head 18 User s Guide for RP7000 Series Active Probe RIGOL Solder in single ended probe head RP7 0203 0 2mm Nickel Wire RP7 0306 When the points to be tested are widely spaced the length of the nickel wire will be increased At this point overshoot and ringing will occurs and the high frequency response will changes To Replace Probe Accessories 1 To replace the probe head Take care not to damage the connecting part to avoid affecting the probe performance when replacing the probe head Replacing Method Disconnect the current probe head from the active probe amplifier Push the new probe head into the active probe amplifier straightly When single ended probe head is used pay attention to their polarities 2 Replace the probe tip The probe tip and probe head are connected with screw thread so please note the screw rotation and strength when removing and installing the probe tip 3 Replace the single ended ground collar Make sure the single ended ground collar is firmly connected to the copper pipe to ensure the probe performance when replacing it User s Guide for RP7000 Series Active Probe 19 RIGOL 4 Toreplace the nickel wire If the nickel wire of the solder in probe head under use become damaged or break off you can replace a ne
9. 7000 Series Overview This chapter guides users to quickly get familiar with the RP7000 series active probe Main topics Probe Introduction General Inspection Probe Dimensions Accessories and Options Active Probe Amplifier Probe Head User s Guide for RP7000 Series Active Probe 1 RIGOL Probe I ntroduction RP7000 with more than 1 5GHz bandwidth is an active probe solution for high frequency application It can be used to measure differential and single ended signals with better common mode rejection RP7000 uses plug on socket probe head and supports 4 types of interchangeable probe heads to optimize the performance and usability Besides its replaceable probe tip prolongs the service life of the probe and the probe tip spacing can be precisely adjusted to fit different test point spacing RP7000 is compatible with the auto identification port of RIGOL DS6000 MSO04000 DS4000 series oscilloscope and can be recognized and configured automatically by this port Its snap in BNC connector enables easier connection with the oscilloscope RP7000 provides various accessories and options and multiple replaceable components which make it applicable to be used in different tests and measurements 2 User s Guide for RP7000 Series Active Probe RIGOL General I nspection 1 Inspect the shipping container for damage If your shipping container appears to be damaged keep the shipping container or cushioning material until yo
10. Active Probe 7 RIGOL Probe Head RP7000 supports hand held probe head and solder in probe head 1 Hand held Probe Head Hand held probe head includes two types hand held differential probe head and hand held single ended probe head Like using common passive probes you can use this kind of probe head to easily measure signals Besides the spacing between the probe tips can be easily adjusted to fulfill your various measurement requirements For hand held differential probe head the spacing between the probe tips is controlled by the roller on the probe head As shown in Figure 3 turning the roller forwards or backwards can precisely adjust the spacing between the two probe tips Figure 3 Hand held Differential Probe Head For hand held single ended probe head rotating the single ended ground collar adjusts the spacing between the single ended ground collar and probe tip as shown in Figure 4 8 User s Guide for RP7000 Series Active Probe RIGOL Figure 4 Hand held Single ended Probe Head Wherein as shown in Figure 5 and Figure 6 probe tip and single ended ground collar are standard accessories and are both replaceable If any of them is damaged during use you can easily replace it with a new one refer to To Replace Probe Accessories RP7000 provides 4 kinds of single ended ground collars for different measurement requirements the structures of the ground collars are as shown in Figure 6 a
11. Do not use your hand to fix the probe head or else the lead resistor soldered onto the probe head might break or fall off what s more the hand held position might also affect the probe performance Wherein the nickel wire of the solder in probe head is a standard accessory If the nickel wire under use became damaged or break off please replace it with an appropriate lead resistor refer to To Replace Probe Accessories User s Guide for RP7000 Series Active Probe 11 RIGOL To Use RP7000 Series Active Probe During the use of RP7000 series active probe correct operations can ensure the probe performance prolong the service life of the probe and ensure the effectiveness of the signal measurement result This chapter introduces in detail the using method of the RP7000 series active probe Main Topics To Connect to the Oscilloscope To Use the Probe Head To Replace Probe Accessories To Adjust Offset Voltage To Calibrate the Probe 12 User s Guide for RP7000 Series Active Probe RIGOL To Connect to the Oscilloscope After RP7000 is connected correctly to a RIGOL DS6000 series oscilloscope the oscilloscope recognizes the probe automatically and provides both power and offset voltage to the probe You can adjust the offset voltage refer to To Adjust Offset Voltage and calibrate the probe refer to To Calibrate the Probe by the front panel menu of the oscilloscope Please connect the probe to the oscilloscope f
12. RIGOL User s Guide RP7000 Series Active Probe Dec 2013 RI GOL Technologies I nc RIGOL Guaranty and Declaration Copyright 2011 RIGOL Technologies Inc All Rights Reserved Trademark I nformation RIGOL is a registered trademark of RIGOL Technologies Inc Publication Number UGE07107 1110 Notices 6 RIGOL products are protected by patent law in and outside of P R C RIGOL reserves the right to modify or change parts of or all the specifications and pricing policies at company s sole decision Information in this publication replaces all previously corresponding materials RIGOL shall not be liable for losses caused by either incidental or consequential in connection with the furnishing use or performance of this manual as well as any information contained Any part of this document is forbidden to be copied or photocopied or rearranged without prior written approval of RIGOL Product Certification RIGOL guarantees this product conforms to the national and industrial standards in China as well as the 1S09001 2008 standard and the 1 014001 2004 standard Other international standard conformance certification is in progress Contact Us If you have any problem or requirement when using our products or this manual please contact RIGOL Technologies Inc E mail service rigol com Website www rigol com User s Guide for RP7000 Series Active Probe RIGOL Safety Terms and Symbols Terms in th
13. ct is proven to be defective within the respective period RIGOL guarantees the free replacement or repair of products which are approved defective For detailed warranty description please refer to RIGOL official website or the warranty card To get repair service or a complete copy of the warranty description please contact with your nearest RIGOL sales and service office RIGOL does not provide any other warranty items except the one being provided by this summary and the warranty statement The warranty items include but not being subjected to the hint guarantee items related to tradable characteristic and any particular purpose RIGOL will not take any responsibility in cases regarding to indirect particular and ensuing damage User s Guide for RP7000 Series Active Probe 25 RIGOL Specifications Technical Specifications Item RP7150 RP7080 Bandwidth gt 1 5GHz gt 0 8GHz Rise Time lt 265ps lt 465ps System Bandwidth 1GHz DS6104 or 0 8GHz DS6104 or DS6102 DS6102 Input Capacitance lt 1pF Input Resistance Input Dynamic Range Input Common mode Range Common Mode Rejection Ratio DC Attenuation Zero Offset Error Offset Voltage Range Offset Accuracy Input Noise Propagation Delay Max Input Voltage Electrostatic Protection 50kQ 2 Differential 25kQ44 Single ended 6 25V 6 75V DC to 100Hz 1 25V gt 100Hz gt 45dB 1MHz 10 1 2 lt 30mV lt 5mV 12V lt 3 of current range
14. er to Table 1 RP7080 Active Probe Kit the ordering number is RP7080 contains all the accessories listed in Table 2 If any accessory or option needs to be ordered separately please refer toTable 2 Table 1 RP7150 Active Probe Kit Ordering NO is RP7150 Standard Accessories Name Ordering NO Qty PCK100 Active Differential Probe Calibration Kit PCK100 1 RP7150 Active Probe Amplifier RP7 0150 1 Solder in Differential Probe Head RP7 0201 1 Solder in Single ended Probe Head RP7 0203 1 Hand held Differential Probe Head RP7 0204 1 Hand held Single ended Probe Head RP7 0205 1 0 2mm Nickel Wire RP7 0306 1 Trim Gauge RP7 0307 1 91Q Probe Tip RP7 0405 8 Straight Acuminate Ground Collar RP7 0501 2 Curved Acuminate Ground Collar RP7 0502 2 Straight Dentiform Ground Collar RP7 0503 2 Curved Dentiform Ground Collar RP7 0504 2 Marker Rings Yellow Pink Light Blue Dark Blue RP 0203 8 User s Guide RP7 0601 1 Probe Bag RP7 0602 1 Storage Box RP7 0603 1 User s Guide for RP7000 Series Active Probe 5 RIGOL Table 2 RP7080 Active Probe Kit Ordering NO is RP7080 Standard Accessories Name Ordering NO Qty PCK100 Active Differential Probe Calibration Kit PCK100 1 RP7080 Active Probe Amplifier RP7 0080 1 Solder in Differential Probe Head RP7 0201 1 Solder in Single ended Probe Head RP7 0203 1 Hand held Differential Probe Head RP7
15. is Manual The following terms may appear in this manual WARNI NG Warning statements indicate the conditions or practices that could result in injuries or loss of life CAUTI ON Caution statements indicate the conditions or practices that could result in damage to this product or loss of data Terms on the Product The following terms may appear on the product DANGER indicates a hazard may immediately happen WARNING indicates potential hazard may happen CAUTION indicates damage to the instrument or other devices connected to the instrument may happen Symbols on the Product The following symbols may appear on the product A A A High Safety Protective Chassis Test Voltage Warning Earth Ground Ground terminal I User s Guide for RP7000 Series Active Probe RIGOL Document Overview This document is used to guide users to get a quick understanding of the RP7000 series active probe as well as its using method Besides this document gives service information relating to general care and cleaning RP7000 series active probe includes the following model Model Bandwidth PR7150 gt 1 5GHz RP7080 gt 0 8GHz Main topics RP7000 Series Overview This chapter gives a brief introduction of the probe including general inspection probe dimensions standard accessories etc To Use RP7000 Series Active Probe This chapter introduces how to use the probe including how to connect to
16. ollowing the steps below 1 Connect the probe head in the figure taking a hand held differential probe head for example with the active probe amplifier If single ended probe head is used during the connection pay attention to their polarities 2 Connect the other end of the active probe amplifier to the channel input or external trigger input connector of the oscilloscope and make sure the connection is tight 3 Use any probe auxiliary device to connect the probe to the circuit to be User s Guide for RP7000 Series Active Probe 13 RIGOL tested 4 To disconnect the probe from the oscilloscope press the button on the probe as shown in the left figure below pull the connector straight out of the oscilloscope as shown in the right figure below and then release the button CAUTION Do not twist the probe on the BNC connector of the oscilloscope or else the probe might be damaged 14 User s Guide for RP7000 Series Active Probe RIGOL To Use the Probe Head Known from Probe Head RP7000 can be connected with 4 kinds of probe heads You can easily change the probe head by using the method introduced in To Replace Probe Accessories This chapter introduces how to use the four kinds of probe heads respectively 1 Hand held Differential Probe Head The hand held differential probe head provides an effective bandwidth of more than 1 5GHz Besides the spacing
17. res below to calibrate the RP7000 active probe using this kit Connect one connector to the calibration board and the female BNC of the cable respectively and then connect the other connector to the other part of the calibration board called part 1 Connect the RP7000 active probe to the analog channel CH1 to CH4 of the oscilloscope illustrations here are based on CH1 Open the probe calibration control menu front panel operation cH gt Probe gt Probe Cal At this point calibration prompt message is displayed in the user interface of the oscilloscope Follow the prompt message to connect part 1 to the oscilloscope Generally connect the BNC male of the connector to the corresponding analog channel and the male BNC of the cable to the Trig Out Calibration port at the rear panel of the oscilloscope Adjust the spacing between the probe tips so as to connect the positive probe tip to the middle signal line on the calibration board and the negative probe tip to the both sides of the middle signal line Note it is recommended to place the probe tips at the middle of the calibration board Press Start and the oscilloscope starts to calibrate the probe The 22 User s Guide for RP7000 Series Active Probe RIGOL calibration will last for about 40 to 50 seconds When probe calibration finished Probe calibration finished or Probe calibration failure is displayed in the user interface of the oscilloscope
18. u have inspected the contents of the shipment for completeness and have checked the probe electrically and mechanically If your probe has damaged during shipping please contact your shipper and carrier for compensation RIGOL will provide no free repair or replacement 2 Inspect the probe If there is any mechanical damage or defect or if the probe does not pass electrical and mechanical tests please contact your RIGOL sales representative 3 Check the Accessories Please check the accessories according to Accessories and Options in this guide If the accessories are incomplete or damaged please contact your RIGOL sales representative User s Guide for RP7000 Series Active Probe 3 RIGOL Probe Dimensions Figure 1 shows the dimensions of the main parts of RP7000 series active probe 80 0mm 4 3mm meee ed eal Figure 1 Probe Dimensions MONO OA AAA a B i EFS TTT DI 25 5mm TOUT User s Guide for RP7000 Series Active Probe RIGOL Accessories and Options This section lists the probe kits standard accessories of the RP7000 series active probe respectively All the components listed below can be ordered from RIGOL RP7150 Active Probe Kit the ordering number is RP7150 contains all the accessories listed in Table 1 If any accessory or option needs to be ordered separately please ref
19. w one The probe head nickel wire should satisfy the following size requirement namely the length must be shorter than 5mm Note If the length of the nickel wire is longer than 5mm the bandwidth specification of the probe will be effected You can use the trim gauge RP7 0307 to measure and cut the nickel wire 20 User s Guide for RP7000 Series Active Probe RIGOL To Adjust Offset Voltage RIGOL DS6000 MS04000 DS4000 series oscilloscope can provide offset voltage to the RP7000 series active probe The offset voltage adjusts the measured signal which exceeds the input dynamic range of the probe within an appropriate range to ensure the measured signal s integrity You can adjust the offset voltage by operating the front panel menu of the oscilloscope and the operation method is as shown below 1 Connect the RP7000 series active probe to the channel input terminal such as CH1 of the DS6000 MS04000 DS4000 oscilloscope referring to To Connect to the Oscilloscope 2 Open the probe offset voltage control menu of the DS6000 MS04000 DS4000 oscilloscope front panel operation CH1 gt Probe gt Bias Voltage and rotate the knob to adjust the value User s Guide for RP7000 Series Active Probe 21 RIGOL To Calibrate the Probe Before using you can use the PCK1000 active differential probe calibration kit to calibrate the RP7000 series active probe Follow the procedu