Home

EKKC 12, 18, 24 R

image

Contents

1. Hoisting screw X4 o E Y CA i 1 Y ee 680 Gaps between hoisting screw rods 840 Indoor unit Lee Se 890 Ceiling opening 950 Decorated surface boards Fig 2 Install dimension of mode EKKC 12 18 R i A Install dimension of mode EKKC 24 R X The drilling of holes in the ceiling must be done by the professional personnel Installation stands for main body of the unit 4 y Y A F Ceiling S Above 20 Fig 3 Notes The dimension for the ceiling openings with marks can be as large as 910mm But the overlapping sections of the ceiling and the decorated surface boards should be maintained at no less than 20mm X Main body of hoisting air conditioner 1 The primary step for install the indoor unit X When attach the hoisting stand on hoisting screw do use nut and gasket individually at the upper and lower of the hoisting stand to fix it The use of gasket anchor board can prevent gasket break off 2 Use install cardboard X Please refer to the install cardboard about the dimension of ceiling opening X The central mark of the ceiling opening is marked on the install cardboard ul YORK BY JOHNSON CONTROLS Install of the Panel Cassette Type Indoor Unit X Install the install cardboard on the unit by bolt 3 piece and fix the angle of the drainage pipe at the outlet vent by
2. Connect the joints for swing flap motor lead wire at 2 places installed on the panel At body At pane At body 57 das At pane Fig 16 dl YORK BY JOHNSON CONTROLS Constitutes and Names of the Panel Cassette Type Indoor Unit Constitutes and Names of the Panel Cassette Type Indoor Unit Drainage equipment inside type Discharge condensate water from indoor unit when cooling Drainage hose Y F E Guide louver F placed in air 2 outlet vent AT Air outlet vent m Connecting pipe Air filter purifier in air inlet grille Air inlet grille EKKC 12 18 24 R dl YORK BY JOHNSON CONTROLS Working Temperature Range Working Temperature Range Working Temperature Range Indoor side state Outdoor side stae Dry bulb Wet bulb Dry bulb Wet bulb temp C oa temp C temp C Rated Cooling 35 Max cooling 48 Min cooling 18 Rated Heating 7 Max heating 24 Min heating a YORK BY JOHNSON CONTROLS Malfunction Debarring Malfunction Debarring A Warning Cut down the main power switch immediately if malfunction such as smell the burning odor etc happened and then contact service center If the
3. X EKKC 12 18 24 R aR y ORK BY JOHNSON CONTROLS Ref Cassette Multisplit Inverter Installation Instructions Johnson Controls Manufacturing Espa a S L is participating in the EUROVENT Certification Programme Products are as listed in the EUROVENT Directory of Certified Products in the program AC1 AC2 AC3 LCP and FC The LCP program covers air condensed water chillers and heat pumps of up to 600 kW User Notice X When operating the entire capacity of the cooperating indoor unit should be not larger than 150 of outdoor unit Otherwise it will cause the shortage of cooling heating capacity X A Breaker or fuse need to be installed in every indoor unit and the capacity should in according with indoor unit s electrical parameter all the indoor units are required to be centralized controlled by a total Switch this Switch can cut off the electric power supply in case of emergency The Breaker or fuse on each indoor units have the function of short circuit prevention and abnormal overload avoiding 1t should be connected in normal situation The total switch controlling the power supply of all the indoor units Before clearing and maintenance job being carried out to the indoor units it is very important to turn off the total power supply switch X In order to turn on the units successfully the main power switch should be opened 8 hours before the operation X After receiving the turn off signal every indoor u
4. Install of the Panel Cassette Type Indoor Unit Install of the Panel Cassette Type Indoor Unit X Schematic diagram of installation spaces Wall va surface v4 o N RI I l jan Wall i aos ae surface i SY 21500 21500 2 o o Es gt Model H unit mm EKKC 12 18 24 R 260 Y Ground surface Fig 1 X Select install location of the indoor unit 1 Obstruct should put away from the intake or outlet vent of the indoor unit so that the airflow can be blown though all the room 2 Make sure that the installation had accord with the requirement of the schematic diagram of installation spaces 3 Select the place where can stand 4 times of the weight of the indoor unit and would not increase the operating noise and oscillate 4 The horizontally of the installation place should be guaranteed 5 Select the place where easy drain condensated coagulated water and easy connect with outdoor unit 6 Make sure that there are enough space for care and maintenance Make sure that the weight between the indoor unit and ground is above 1800mm 7 When installing the steeve bolt check if the install place can stand the weight 4 times of the unit s If not reinforce before installation Refer to the install cardboard and find where should be reinforced A Note There will be lots of lampblack and dust stick on the acentric heat exchanger and water p
5. abnormal state is maintained the unit may be damaged or electric shock or fire may be happened Do not refit the conditioner Please contact service center to repair or move the conditioner Ak Check the following items before contacting maintenance center Phenomena Reason Remedial Measures Blow of fuse or breaker Change fuse or close breaker Power cut Air conditioner doesn t Don t connect with power run at all Low batteries of wireless remote controller Wireless remote controller exceed remote control area Air conditioner runs but Blockage in inlet or outlet vent of stops immediately indoor or outdoor unit Blockage in inlet or outlet vent of indoor or outdoor unit Improper of temp setting Low setting of fan speed Incorrect of wind direction Restart when there is power supply Connect power well Change new batteries Signal could be received within 8m Clean out blockage Clean out blockage Adjust settings in wireless remote controller Adjust settings in wireless remote controller Adjust settings in wireless remote controller Abnormal cooling or Door or window opened heating Close Direct sun burn Too many people in room Too many heater in room Filter blocked by dirt Hang curtain or jalousie before windows Clean filter 15 dl YORK BY JOHNSON CONTROLS Malfunction Debarring Instruction If problem still cannot found
6. discharge vent or outlet grill Please make sure that the unit is installed in the place that can bear the weight of it adequately If the place is not strong enough the air conditioner may drop and cause casualty event Don t spray or smear any oil paint or insecticide on the surface of unit otherwise fire may be leaded Do not refit the conditioner Please contact the agency or prefect ional personnel to repair or move the conditioner An all pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring Note Please check and make sure that the cord drainage pipe and tubes are connected in the correct way to prevent leakage of water refrigerant electric shock or fire The main power must connectable to the earth in order to assure the conditioner earthing effectively and to prevent electric shock Please don t connect the earthing line with the gas pipe water pipe lightening rod or the connecting line of telephone The air conditioner should be turned off at least after 5 mins operation otherwise it would affect the duration of the unit Don t let the children operate the air conditioner Please don t operate the unit by wet hand Please turn off the main power of the unit before cleaning the conditioner or change the filter Please cut off the main power if the conditioner will be used for a long time ul YORK BY JOHNSON CONTROLS
7. out after above checking please contact service center and instruct phenomena and model xK The following circumstance are not malfunction Air conditioner doesn t off run When opening power Mist is blown from air oe When cooling conditioner Slight click sound heard once begin running Hissing sound heard continuously when cooling Malfunction Reason Start up unit immediately after turned The overload protects switch makes it run after 3 minutes delay Run for about 1 minute without other actions The high humidity air in room is cooled rapidly Sound of initialization for electric expand valve The sound for gas refrigerant flowing in the unit Hissing sound heard when staring or The sound for gas refrigerant stops Noise is heard from air S stopping flow conditioner Slight hissing sound heard when Sound for running of drainage system running or after running The grating sound caused by expands Creak sound heard when running or of panel and other parts for the after running change of temperature Dust be blown for air Started up after long time s doesn t Dust in indoor unit be blown out conditioner runs This is because when air conditioning Odor gives out from air odors or cigarette smoke from the When running conditioner room that was sucked in is discharged again A After sales Service When having quality or other p
8. DARDS AND TECHNICAL SPECIFICATIONS pn APPLIED Pri EN ISO 9001 EN ISO 14001 Dl ba DAVID MURRAY USG LOGISTICS MANAGER PLACE Sabadell Espa a SIGNATURES Johnson Y Controls www johnsoncontrols com
9. SS ss E gt A LD a 5 gt ee Fig 17 Fig 18 3 Clean Adopts cleaner or water to wash filter if the filter is too dirty like oil stain on it adopts warm water lower than 45 C with neutral scourer to clean it then dry it in the shade A Note Do not clean the filter by hot water whose temp is higher than 45 C to prevent fade or deformation Do not burn it on fire or the filter would catches fire or deformation 4 Install air filter Fix the 3 purifiers on filter install filter on the several bulges on top of air inlet grille pull the handle behind air inlet grille toward inside to fix filter As shown in fig 19 5 Close air inlet grille Refer to the 1 step Maintenance Method dl YORK BY JOHNSON CONTROLS Maintenance Method LLE SS RS BY BS R FT OL Fig 19 Ak Clean air inlet grille 1 Open air inlet grille the same with the 1st step of Clean Air Filter 2 Take out air filter the same with the 2nd step of Clean Air Filter 3 Take out air inlet grille Open air inlet grille for an angle of 45 as shown in fig 20 rise it 4 Clean Clean it by pubescence brush water and neutral cleaning then throw water or dry 1t A Note Do not use water above 45 C to wash the panel to prevent fade or deformation 5 Install air inlet grille refer to 3rd step 6 Install air filter refer to the 4th step of Clean Air Filter 7 Close air inlet grille refer to the Ist ste
10. bolt 3 Adjust the unit to the suitable install place Refer to the fig 3 4 Check if the unit is horizontal Inner drainage pump and bobber switch are included in the indoor unit check if 4 angle of every unit are horizontal by water lever If the unit is slant toward the opposite of the coagulate water flow there may be malfunction of the bobber switch and lead water drop 5 Backout the gasket anchor board used to prevent gasket break off and tighten the nut on it 6 Backout the install cardboard Nut supplied at scene Gasket attachment isis stand Gasket anchor board Tighten double nuts attachment Fix the hoisting stand firmly Fix the gasket firmly Bolt of one of the angle of outlet pipe is fix on the angle of the drainage slot Center of the ceiling opening Install cardboard f Bolt ttachment Polyethylene pipe Bolt attachment Fix the install cardboard Fig 4 A Note Please do tighten the nuts and bolts to prevent air conditioner break off X Connection of the refrigerant pipe X When connect the pipe to the unit or backout it from the unit please do use both spanner and torque wrench as shown in fig 5 X When connect smear both inside and outside of the flare nut with freeze motor oil screw it by hand and then tighten it with spanner X Refer to form 1 to check if the wrench had been tightened too tight would mangle the nut and lead leakage X Examine the connection p
11. e louver Screw bolts in both end of guide louver to loose Note Do not wipe guide louver powerfully when cleaning otherwise fluff on surface would fall off 2 Install guide louver Rotate guide louver slightly could install the protruding edge of both end into grooves on both end of guide louver and then tighten bolts X Maintenance before or after usage season Check before the usage season X Check if there is blockage in inlet or outlet vent of air conditioner X Check if the earthing wire had earthed reliably X Check if the air filter had been installed well X In order to start up the air conditioner smoothly after long time s turned off turn on the main power supply 8 hours before turning on the air conditioner Maintenance after usage season X Clean filter and body of air conditioner X Cut off the main power supply of air conditioner X The cooling or heating capacity and sound level are tested before leaving factory X Ifthe parameter changed refer to the data offered on nameplate dl YORK BY JOHNSON CONTROLS 20 DECLARACION CE DE CONFORMIDAD SOBRE MAQUINAS FABRICANTE JOHNSON CONTROLS MANUFACTURING ESPA A S L DIRECCI N Paseo Espronceda 278 08204 SABADELL Certificamos que el equipo descrito ha sido dise ado fabricado y probado de conformidad con los requisitos b sicos de la Directiva de Equipos a presi n 97 23 CEE y sus correspondientes m dulos de aplicaci n As mismo certifica
12. from the rubber plug A and impact them well individually by impact fastener Wiring according to the indoor side circuit diagram X Fix the impact fastener after connection X Entwine the small sponge on the electric wire do entwine it to prevent condensation X Impact tightly by impact fastener after connection and then fit on the electric box X Connect the 3 cord rubber wire to the counter terminal of the 3 way terminal board The power cord reference Power cord standard recommending table To indoor unit Agg Ja NG power supply 3 way terminal board _4 core rubber wire To outdoor unit Impact fastener Fig 12 Power cord standard recommending table Power Supply Earthing Permit Min Model A 2 2 V Ph Hz Section mm Section mm EKKC 12 18 24 R 220 240V 1Ph 50Hz HOSVV F 1 0 mm X1 HOSVV F 1 0 mm X3 10 a YORK BY JOHNSON CONTROLS Install of the Panel Cassette Type Indoor Unit X Install the panel 1 Set the panel to the indoor unit body by matching the position of the swing flap motor of the panel to the piping position of the panel to the piping position of the indoor unit as shown by fig 13 2 Install the panel Install the panel on the indoor unit temporarily When install hang the latch on the hook that is located on the opposite side of the swing flap on the panel of the indoor unit 2 positions Hang the rema
13. ining 2 latches to the hooks on the sides of the indoor unit Be careful not to let the swing motor lead wire get caught in the sealing material 3 Screw the 4 hexagon head screws under the latches in about 15mm The panel would rise Adjust the panel by turning it toward the direction pointed by the arrow as shown in fig 13 so that the adjust board connect the ceiling well 6 Tighten the screws until the thickness of the sealing material between panel and indoor unit reduced to 5 8mm Hook sed Sealing material Ceilin 5 Z z 5mm to 8mm 7 Air outlet vent Decoration panel Fig 13 Notes 1 Improper screwing of the screws may cause the troubles shown in fig 14 Air leak Air leak from ceiling A aen ya 0 Water condensatation water drop Fig 14 dl YORK BY JOHNSON CONTROLS Install of the Panel Cassette Type Indoor Unit 2 If gap still exist between ceiling and decoration panel after tightening the screws readjust the height of the indoor unit As shown in fig 15 If the raising lever and drain hose are not affect can adjust the height of indoor unit by the hole on the corner of panel z I J S E Gaps are not allowed Fig 15 X After fixing be sure no gap left between the ceiling and the panel 3 Wiring of the decoration panel Fig 16
14. ipe to see if it had gas leakage then take the treatment of heat insulation as shown in the fig 5 X Only use median sponge to entwine the wiring interface of the gas pipe and heat preservation sheath of the gas collection tube dl YORK BY JOHNSON CONTROLS Install of the Panel Cassette Type Indoor Unit Smear freeze motoroil here Median sponge attachment entwine the wiring interface 8 with seal mat Thread fasten x4 Torque wrench Heat preservation sheath of liquid inlet tube attachment for liquid tube 4 Spanner Heat preservation bS sheath of gas collection AY A H El tube attachment for Gas collection tube gas tube Flare nut Wiring interface Liquid inlet tube Fig 5 Form 1 The tightening torque needed for tightening nut Diameter Inch Surface thickness mm Tightening torque N m gt 05 15 30 N m 3 8 gt 0 71 30 40 N m 1 2 gt 1 45 50 N m 5 8 gt 60 65 N m 3 4 gt 1 70 75 N m X Drainage hose 1 Install the drain hose X The diameter of the drain hose should be equal or bigger than the connection pipe s The diameter of polythene pipe Outer diameter 25mm Surface thickness gt 1 5mm X Drain hose should be short and drooping gradient should at less 1 100 to prevent the formation of air bubble X If drain hose cannot has enough drooping gradient drain raising pipe should be added X To preven
15. isposed together with the domestic waste This product has to be disposed at an authorized place for recycling of electrical and electronic appliances E Thank you for your selecting of YORK air conditioner please read this usage and install instruction carefully and keep it well in order to use this unit correctly a YORK BY JOHNSON CONTROLS Contents Salet MILO AEON nannake ite ne eben 4 Install of The Compact Panel Cassette Type Indoor Di isrionar rme 5 Constitutes and Names of Parts of Compact Panel Cassette Type Indoor Unit 13 Working Temperature Rasen ii 14 Maltuneti n De DAD a 15 Maintenance Method manana raven 17 dl YORK BY JOHNSON CONTROLS Safety Information Safety Information Please read this manual carefully before use this unit and operate it correctly according to the guide in this manual Please take specially note to the meaning of these two marks A Warning This mark means that it may cause casualty or badly heart if the operation is incorrect Note This mark means that it may cause casualty or property loss if the operation is incorrect Warning Do not adopt fuse with unsuitable capacity or adopt iron thread instead of fuse otherwise malfunction or fire may happened 9 Cut down the main power switch immediately if malfunction such as smell the burning odor etc happened Maintain ventilation to prevent oxygen leakage in room Don t insert finger or stick like things into
16. llowing process if several drain hoses join together Above 100mm T tie in join drain hose re a A AN The specs of the selected join drain hose should fits the running capacity of the unit Fig 10 2 Check the smoothness of drain after installation X Check the drain state by immitting 600cc water slowly from the outlet vent or test hole X Check the drain in the state of refrigerating after installation of the electric circuit dl YORK BY JOHNSON CONTROLS Install of the Panel Cassette Type Indoor Unit Way of immiting Drain hose Test hole cover Drain vent for repair use plastic O l stopper is included drain the water A a in waterspout by this outlet vent Test hole A S T Abovel00mm lt Immiting water from the rest hole gt Plastic water pot The length of the pipe should be about 100mm lt Immiting water from the outlet vent terminal gt Fig 11 X Electrical wiring A Note The power of the entire indoor unit must be connected in outdoor unit X About the electrical wiring please see the circuit diagram attached with the unit X All the installation of electrical wiring must be done by professional personnel X Please do take the earthing treatment Wiring method of connection unit and controller X Connection wiring communication Q Open electric box cover drag the wiring communication
17. mos que el equipo es conforme a las exigencias b sicas de las Directivas Europeas que le son aplicables incluidas las modificaciones de las mismas y las correspondientes transposiciones a la ley nacional APLICACI N DE LA M QUINA AIRE ACONDICIONADO REFRIGERACION EKKC 12 18 24R DIRECTIVAS DE LA CE APLICADAS 2006 95 CEE 2004 108 CEE 97 23 CEE NORMAS ARMONIZADAS APLICADAS EN6335 1 EN6335 2 40 EN62233 EN61000 6 3 EN61000 6 1 EN61800 3 NORMAS INTERNACIONALES Y TT P ESPECIFICACIONES TECNICAS APLICADAS EN ISO 9001 EN ISO 14001 Coal Musa DAVID MURRAY nee Sabadell Espa a RRMA USG LOGISTICS MANAGER DECLARATION OF COMPLIANCE ON MACHINERY MANUFACTURER JOHNSON CONTROLS MANUFACTURING ESPA A S L ADDRESS Paseo Espronceda 278 08 204 SABADELL We hereby certify that the mentioned equipment has been designed manufactured and tested in accordance with essential requirements of Pressure Equipment Directive 97 23 EEC and its relevant application modules We futher certify that the equipment complies with the essential requirements of the European Directives applicable including their modifications and the corresponding transpositions from the national law APPLICATION OF THE MACHINE AIR CONDITIONER COOLING _ EKKC 12 18 24R TYPE EC STANDARDS APPLIED 2006 95 CEE 2004 108 CEE 97 23 CEE MATCHING STANDARDS APPLIED EN6335 1 EN6335 2 40 EN62233 EN61000 6 3 EN61000 6 1 EN61800 3 INTERNATIONAL STAN
18. nit will continue to work for 20 70sec to make use of the rest cool air or the rest heat air in the heat exchanger while preparing for the next operation And this is normal X When the selected operating mode of the indoor unit are clash with the operating mode of the outdoor unit the malfunction light will blink after 5s on the indoor unit or remote controller showing that the operation clash then the indoor unit will stop At this time change the operation mode of the indoor unit to the one that would not clash with the outdoor operating mode to make the operation normal The cooling mode is not clash with the dry mode while the fan mode is not clash with any mode X The appliance shall not be installed in the laundry X An all pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring X Information regarding transport storage temperature 25 55 C is missing X Main switch provided by end user main switch handle should be black or gray it can be locked in OFF position with padlock X The main disconnection device should be explained in user manual and the height should be recommended at 0 6 1 7m over current protection is required EN 60947 3 EN 60947 2 X The cooling range of the unit is the outdoor environment temp 5 48 C DB the heating range of the unit only for the heat pump type unit is the outdoor environment temp 15 27 C WB This product must not be d
19. p A Install and change of air purifier 1 Open air inlet grille the same the Ist step of Clean Air Filter 2 Disassembly purifier As shown in fig 21 disassembly air filter screw out fixing bolts fixed on purifier on filter then purifier could be disassembly 3 Take out the package sack of static fiber net filter then install the filter in stand of purifier and fix purifier on air filter 4 Install air filter the same with the 4th step of Clean Air Filter Air filter Purifier filter Stand for purifier Fix bolt of 4 purifier Fig 21 18 a YORK BY JOHNSON CONTROLS Maintenance Method Function and usage period for air purifying X Could adsorb CO CO benzene aldehydes and odor of gasoline etc X Could adsorb deleterious material that is smaller than lm in air as dust pollen bacteria and virus X Usage period is 6 months to 1 year If it is necessary to be changed purchase new purifier in the nearest York special engaged maintenance center X Clean Outlet vent and Surface Panel X Clean the surface panel by soft dry cloth or wet cloth with neutral scourer X Itis forbidden to clean surface panel by gasoline benzene diluents cleansing powder etc X If the guide louver is too dirty it may be removed to be cleaned As narrated below Disassembly and install of guide louver 1 Disassembly guid
20. roblems when purchasing air conditioner please contact the local service center 16 a YORK BY JOHNSON CONTROLS Maintenance Method Maintenance Method When air conditioner won t be used for a long time please cut off the main power supply of air conditioner A Warning 9 Do turn off the unit and cut off the main power supply when cleaning the air conditioner otherwise electric shock or harm may happen Itis forbidden to wash air conditioner by water rinsing otherwise electric shock may happen xX Cleaning air filter Air filters should be cleaned by professionals with proper operation to ensure personal safety When the usage environment has lots of dust air filter should be cleaned more frequently about once 6 months 1 Open air inlet grille Loosen two screws on the air inlet grille with a screwdriver And pull the 2 handle on air inlet grille at the same time with the direction showed by arrow in fig 17 pull down slowly Reverse when closing 2 Disassembly air filter As shown in fig 18 pull the handle behind air inlet grille raise 1t and disassembly Then discharge the 3 purifier fixed on filter G N An LL TE p purifier Abe E E gS ST SISA EE A W ES B
21. t bent of the drain hose the distance between hoisting stand should is 1 to 1 5m O Correct 1 100 or more gradient Xx wrong Fig 6 X Use the drain hose and clamp attached Insert the drain hose to the drain vent and then tighten the clamp X Entwine the big sponge on the clamp of drain hose to insulate heat X Heat insulation should be done to indoor drain hose dl YORK BY JOHNSON CONTROLS Install of the Panel Cassette Type Indoor Unit Sponge attachment Clamp attachment Clamp fas Sponge gray Drain hose Below 4mm Fig 7 Drain stepup pipe note X The install height of the drain raising pipe should less than 280mm X The drain raising pipe should form a right angle with the unit and distance to unit should not beyond 300mm Roof Within 300mm 1 1 5m Hoisting stand Drain hose below280mm attachment ST A Yt DN Drain raising E y hose S G AA 2 x 2200 8 oOo He Clamp attachment Fig 8 Instruction X The slant gradient of the attached drain hose should be within 75mm so that the drain hole doesn t has to endure the unnecessary outside force Drain hose attachment g g y yh amp A E ES E D 2 ro oO Me Fig 9 X Please install the drain hose according to the fo
22. ump in dining room and kitchen which would reduce the capacity of heat exchanger lead water leakage and abnormal operation of the water pump The following treatment should be taken under this circumstance 1 Ensure that the smoke trap above cooker has enough capacity to obviate lampblack to prevent the indraft of the lampblack by the air conditioner 2 Keep the air conditioner far from the kitchen so that the lampblack would not be indraft by the air conditioner X Important notice X To guarantee the good performance the unit must be installed by professional personnel according with this instruction X Please contact the local York special nominated repair department before installation Any malfunction dl YORK BY JOHNSON CONTROLS Install of the Panel Cassette Type Indoor Unit caused by the unit that is installed by the department that is not special nominated by York would not deal with on time by the inconvenience of the business contact X Dimension of ceiling opening and location of the hoisting screw M10 650 1 570 T 4 4 E 400 2 EN T 2 Refrigerant pipe as as Blo z ef o B dal al 4 2 215 2 8 5 a sl 2 2 l el 5 yo Me a 2 al g 7 7 T E S O E R Srg e 9j S Al 8 Es S a N E 570 604 650 a 9 s 2

Download Pdf Manuals

image

Related Search

Related Contents

JELLY GLOBE  Direct V1 Integration Instructor User Manual  DELL Venue 8 Pro 3845 32GB Black  Rongeurs de Kerrison Integra™ INDICATIONS D`EMPLOI  POSE des PAVÉS en H  

Copyright © All rights reserved.
Failed to retrieve file