Home

User Manual Operation instructions - Glow-worm

image

Contents

1. If the system is used for ventilation in locations with room dependent combustion equipment depending on the room air the corresponding flue gas extraction systems must be checked and maintained by a trained technician It is mandatory to prevent flue gas leakage from the combustion equipment www glow worm co uk Important Information Operation The Atmosorb can only be used if all ventilation pipes are connected and the unit is closed The Atmosorb unit must only be operated with the supplied filters installed Regularly check whether the filters are dirty or damaged We recommend to visually check the filters every 6 months and to replace them every 12 months or after 2000 operating hours at the latest If the system is to be used for ventilation purposes in locations with room dependent combustion facilities the corresponding flue gas extraction systems must be checked and maintained by a competent person approved at the time by the Health and Safety Executive Do not modify the unit the outside air fresh air exhaust and discharge air ducts the pipes for condensation water and the unit mains connection This also applies to alterations to structural elements in the vicinity of the unit which might affect its operational safety do not obstruct the air inlets and outlets with doors ceilings windows and walls even temporarily Do not cover the air inlets and outlets e g with clothes or similar When layi
2. Glow worm Atmosorb Domestic ventilation system with heat recovery and wired remote control Instructions for Use Tobeleftwiththeuser www glow worm co uk WARNING SHEET METAL PARTS This unit contains metal parts components and care should be taken when handling and cleaning with particular regard to edges SEALED COMPONENTS Under no circumstances must the User interfere with or adjust sealed parts Customer service call 01773 596510 Technical helpline 01773 828300 General and Sales enquiries Tel 01773 824639 Fax 01773 820569 CE www glow worm co uk HRD 275 HRD 350 CONTENTS Important Information 5 Ventilation Heat Recovery Unit Design 8 Operating Instructions 9 Description 10 Operation 11 User Controls 12 Cleaning the Filters 18 These instructions are an integral part of the appliance and must be left with the user Please read these instructions and follow them carefully for the safe and economical use of your boiler www glow worm co uk Important Information Control of Substances Hazardous to Health Under Section 6 of The Health and Safety at Work Act 1974 we are required to provide information on substances hazardous to health The adhesives and sealants used in this appliance are cured and give no known hazard in this state Electrical Connection The unit MUST be earthed It MUST be connected to a permanent 230V ac 50Hz supply Connection of the whole electrical
3. LEVELS amp a BN so OvSsl VENTILATORS BYPASS DISPLAY MULTI FUNCTIONAL DISPLAY Diagram 3 gag Multi function display right KWh Information level Time programming level y Installer level Y Service diagnostic level www glow worm co uk User Controls a a E TH FR SA SU BA gt AB BB n Diagram 4 From the basic display you can select and change the major Press mode in order to change the operating mode functions by pressing the mode button and then the or You can select the following settings using the or buttons buttons to change their values By pressing the mode button you can move from one menu item to another 3 Day mode Press the mode button until you have reached the desired Irrespective of the time programme the remote function menu Press the or buttons to achieve the control switches the fans into day mode high fan desired value NOTE After the necessary settings have been made no Q Night mode confirmation is required Irrespective of the time programme the remote 10 seconds after the last input the indicated function is control switches the fans into night mode low fan automatically activated and then the display returns to the basic display www glow worm co uk 13 14 User Controls Automatic operation The change between the day and night oper
4. ach the maximum energy saving if you keep the windows closed and ensure the necessary air exchange by the operation of the domestic ventilation unit Venting the room is always possible by opening the windows www glow worm co uk Description From the Atmosorb to the living room 92874 OUTSIDE AIR BYPASS DISCHARGE From the living space to the Atmosorb AIR From outside to the Atmosorb EXHAUST From the Atmosorb to outside AIR AERATION WITH THE oo OUTSIDE AIR FRESH AIR FILTER gt 9284 D FRONT PANEL www glow worm co uk Operation Bypass optional Functional Overview of the Digital Remote The Atmosorb can be equipped with a bypass which is fitted Control on the top of the device see diagram 2 The Atmosorb is equipped with a digital remote control to With a bypass installed the user may operate the so called operate the unit free cooling mode during the summer months with the The remote control allows you to set various operating outside temperature falling below room temperature during programs In addition you can set special functions as well the night The cooler outside temperature will not be warmed as a time controlled function of the ventilation unit please by the device before it was blown into the room To protect see the User Controls section the bypass valve from dirt we recommend an outside air filter of the filter class at least G3 T
5. asis We recommend making a maintenance agreement The operational reliability of the device can be impaired resulting in damage to property or personal injury if maintenance work is not carried out You as the owner or user may execute the following maintenance work yourself Clean and replace the filters in the domestic ventilation unit Clean and replace the filter in the bypass casing if used Clean the fresh air or exhaust air valves in the living space Reset the time interval for filter replacement in accordance with section User Controls It depends on the contamination levels how often the filters must be cleaned or replaced We recommend to regularly check the filters during the initial operational period and assess the need to clean them e g every three months If you then feel that the filters are only slightly contaminated or dirty you may extend the interval NOTE Replace the filters at least once a year or after a maximum of 2000 operating hours You can clean the filters with a vacuum cleaner If this is not enough the filters must be replaced DO NOT clean the filters with water or other liquids Dispose of the used filters with the domestic waste Cleaning or Replacing the Filter To check and clean the filters please proceed as follows e Unplug the Atmosorb from the mains e Pull the filter out of the unit e Remove the filter handles from the filters NOTE Before inserting the
6. ation occurs automatically Additionally the current operating mode is displayed GFF Minimum operation Irrespective of the time programme the remote control switches the fans into the lowest stage Press mode twice Fan stage 3 Display shows HIGH Press or in order to set the period of time The 3rd fan stage is active at this time You can have a 0 to 24 hrs boost use the or buttons to set To deactivate this function set the period of time to 0 0 Press mode three times Bypass in stand by Display shows COOL If the bypass unit is not fitted this menu point will not show Press or to set the number of days between 0 and 60 during which the bypass shall be in stand by mode Under the correct temperature conditions the bypass engine switches to summer mode Check and setting of the time Press mode several times in order to select days of the week hours and minutes as required The selected category flashes in the display Press or to change days of the week hours and minutes Check and reset of the filter timer Press mode six times Display shows FILT The timer indicates the number of days after the last reset since the filter has been used Press mode Return to basic display If no new setting is executed for more than 10 seconds the display will automatically return to the basic display www glow worm co uk User Controls Programming of the Clock Timer With the pr
7. d from the kitchen bathroom and WC With the digital remote control the user is able to automatically switch and adapt the domestic ventilation unit power to their own requirements The unit ensures Aconstant air exchange in the building The hygienic minimum air exchange in accordance with UK building regulations Part F Energy savings thanks to high efficiency heat recovery Ahigh hygiene standard due to the prevention of humidity and mould damages of the building The exact model description of the unit is to be found on the identification plate positioned below the unit Electrical Supply Failure The appliance will not work without an electrical supply and normal operation should resume when the electrical supply is restored If the applaince does not resume normal operation proceed in accordance with the fault finding table in this document In case it is not possible to eliminate the fault contact Glow worm s own service organisation using the telephone number on the inside front cover of this booklet www glow worm co uk Operating Instructions Intended Use The Glow worm domestic ventilation units are built and designed according to accepted safety rules and regulations Nevertheless improper use can cause serious or fatal injury to the user or others and the appliance or other property can be damaged This device is not designed to be used by persons including children unless they are supe
8. emain activated till the next programmed switch over to day mode starts Holiday function If you select the holiday function the fan stage is set toa minimum value for a period in days of up to 99 days At 0 00 hours midnight a day is subtracted from the period of days you have chosen www glow worm co uk User Controls Information Level e DATE Press and hold the prog button to reach the info level In The current date is displayed addition to identifying the controller the information level is Prerequisite is to activate the calendar first used to quickly and easily check the set operating times Each time window may be individually opened To return to the basic display press and hold the prog button To scroll through the information levels press prog the information will be displayed as follows e H1 H2 and H3 Timer settings e HRD 275 350 Displays the unit type e FILT Filter days Indication of number of days that the filter has been operated since the last filter reset e AIR Current air flow supply in m h e BYP Display of the fresh air temperature in oC if a bypass has been installed www glow worm co uk 17 Cleaning the Filters Continued efficient operation reliability and a long service life as well as safety require inspections and maintenance work to be regularly carried out by a competent person approved at the time by the Health and Safety Executive and on an annual b
9. filters please ensure the correct positioning in order to avoid damaging the filters e Position the filter handles on the clean or new filters On the one side the filter handles are fitted with guides which must be pushed into the grooves in the unit The upper filter of the Atmosorb and the bypass filter are mounted with these guides pointing to the bottom The lower filter is mounted with the guide pointing to the top e Push the filters back into the unit e To operate plug the mains plug back into its socket There are fine filters available as well as the standard filters Description Filter class Ordering number Filter set G3 0020023930 Filter Bypass G3 0020023931 Fine filter set F6 0020026061 Fine filter Bypass F6 0020026118 If you intend to use these filters please contact an expert technician www glow worm co uk 18 www glow worm co uk 19 0020088554 0020088554 01 08 09 Because of our constant endeavour for improvement details may vary slightly from those shown in these instructions Glow worm Nottingham Road Belper Derbyshire DE56 1JT
10. he filter is installed on site into the outside air duct possibly close to the air inlet Switching on and off The Atmosorb is supplied with electrical power via a 230 V mains line e Insert the mains plug into the 230 V socket The electronics of the ventilation appliance is starting The display shows the unit type display 275 or 350 and then after about 3 seconds the indication switches to the basic display e To switch off the unit pull the mains plug out of the plug socket Using the off menu point on the remote control switches the unit to the lowest fan speed To set the remote control to the off position press mode and then the button until off is displayed www glow worm co uk 11 User Controls Symbol Meaning Special function Energy saving Special function Advance Special function Holidays Static 2nd fan stage day mode Flashing 3rd fan stage HIGH Off 1 fan stage night mode Static Cooling required Flashing Bypass open summer mode Off Bypass not fitted or closed Automatic mode Day mode 2nd fan stage OQO lk mD Night mode 1st fan stage OFF Mode with fan stage holidays minimum ceg M0 TU WE TH FR SR SU Actual room temperature Day of week E E E Multi function display left time SPECIAL FUNCTIONS OPERATION MODES gt WEEKDAYS ROOM TEMPERATURE OPERATOR
11. ng floor materials do not block or reduce the vent apertures at the bottom of the doors To make alterations to the unit or to its environment you must refer to the suitably qualified expert technician who is qualified to do this work Servicing This product should be serviced regularly to optimise its safety efficiency and performance The service engineer should complete the relevant Service Record on the Benchmark Checklist after each service The Benchmark Checklist may be required in the event of any warranty work and as supporting documentation relating to home improvements in the optional documents section of the Home Information Pack To ensure the continued efficient and safe operation of the boiler it is recommended that it is checked and serviced at regular intervals The frequency of servicing will depend upon the site conditions and usage but in general once a year should be enough Only competent persons approved at the time by the Health and Safety Executive are authorised to execute repair and maintenance work with the exception of replacing the filters It is recommended that you carry out a visual inspection of the filters at least every 6 months and replace the filters every 12 months or at least after 2 000 hours of operation To obtain service please call your installer or Glow worm s own service organisation using the telephone number on the inside front cover of this booklet www glow worm co uk Im
12. ogramming button you can change the times for the timer mode With activated timer function Atmosorb will switch between the first and the second stage time controlled e Outside the time window Stage 1 Q night mode e Within the time window Stage 2 day mode It is possible to set up to three different switching on and off times time windows for each day of the week In the display of the remote control these time windows are shown as H1 H2 or H3 You can combine individual days in groups or a week block The following groups are possible e Press the prog button again to show the starting time press the or to change the flashing value Do this for hours then minutes Press prog to change from hours to minutes e Press the prog button again to show the end time press the or to change the flashing value e Terminate programming of the operating time by pressing the mode button Factory set operating times are Time window Day of the Start time End time week Block H1 MO FR 6 00 22 00 H1 SA 7 30 22 30 H1 SU 7 30 22 00 MO FR SA SU MO SU NOTE Within the programming level you can navigate with the mode and or push buttons With the mode you can change within one programming level from one menu item to the other Push the mode button several times in order to reach the desired function The parameter you want to change is flashing and an indicati
13. on arrow appears With the or you can change the flashing value The operating times are set as follows refer to diagram 4 for the layout of the control panel e From the basic display press the mode button several times until a flashing H1 is displayed e Select the time window H1 H2 or H3 using the and buttons e Press the prog button to select day or a week block press the or to change the flashing value www glow worm co uk 15 16 User Controls Special functions From the basic display you select the function by pressing the prog button NOTE After the necessary settings have been made no confirmation is required 10 seconds after the last input the indicated function is automatically activated and then the display returns to the basic display By pressing the prog button once you can also deactivate an active special function The deactivation takes 2 seconds By selecting another special function the currently activated special function is terminated It is only possible to operate one special function at a time Energy saving function With the energy saving function the activated fan stage is set to night mode for a limited period of time You can alter the period in hours and minutes minimum 2 30 h Then the remote control switches back to the timer mode Advance function Y The advance function is used to alter the set timer program and activate day mode The function will r
14. portant Information Cleaning The Atmosorbs casing can be cleaned using a mild liquid detergent with a damp cloth then a dry cloth to polish Do not use any form of abrasive or solvent cleaner as you may damage the paintwork The filters on the Atmosorb or bypass can be cleaned with a vacuum cleaner DO NOT clean with water or any other liquid See section Cleaning the Filters Recycling and Disposal The Atmosorb as well as the packaging consist mainly of recyclable raw materials The filters used with the unit may be disposed of with the normal household waste Please ensure that the unit and the other accessories are disposed of properly DO NOT dispose these with normal household waste Leave the disposal of the transport packaging to the qualified servicing company which installed your Atmosorb www glow worm co uk Ventilation Heat Recovery Unit Design Description The domestic ventilation unit consists of a central ventilation appliance for air exchange with heat recovery and a remote control For summer operation you can obtain a bypass as an accessory It can directly provide living rooms with cool external air whenever it is necessary The external air flow bypasses the heat exchanger The unit is connected to an air ducting system which is equipped with silencers pre filters fresh air and exhaust air grilles and louvres Fresh air grilles supply fresh air to the living areas and stale moist air is extracte
15. rvised by someone who is responsible for their safety or have been instructed how to use the device Children must be supervised to ensure they do not play with the unit The domestic ventilation unit must have been installed by a competent person approved at the time by the Health and Safety Executive who is responsible for the observance of the existing regulations rules and guidelines Due to high level of dust operation during the construction phase is not allowed The domestic ventilation units are specifically designed for the ventilation of residential spaces The remote control including the operating mode selector and the timer must only be used for controlling the domestic ventilation unit as described in these instructions it is not designed for any other purpose Any other or additional use is considered to be improper The domestic ventilation unit is not suitable for ventilating swimming pools The manufacturer supplier shall not be responsible for any damages resulting from such improper use The user alone bears the risk Intended use includes observing the operating and installation manual and all other applicable documents as well as adhering to the maintenance and inspection conditions Energy Saving Although this unit is used to increase comfort and energy savings it is possible to maximise energy savings if you observe the following At low ambient temperatures below the room temperature you will re
16. system of the unit including any heating controls to the electrical supply must be through one common isolator and must be fused to 3 Amps maximum The colours of three core flexible cable are blue neutral brown live green and yellow earth The local mains power isolator must always be easily accessible Testing and Certification The Atmosorb is tested and certificated for safety and performance It is therefore important that no alteration is made to the unit without permission in writing by Glow worm Any alteration not approved by Glow worm could invalidate the certification unit warranty and may also infringe the current issue of the statutory requirements CE Label The CE label shows that the Atmosorb ventilation unit complies with the basic requirements of the following directives and guidelines Low voltage Directive 73 23 EEC modified with Directive 93 68 EEC EMC Directive 89 336 EEC modified by the Directive 91 263 EEC 92 31 EEC and 93 68 EEC Assembly and Installation The installation of the device can only be carried out by a competent person approved at the time by the Health and Safety Executive who will be responsible for the correct installation and start up The competent person approved at the time by the Health and Safety Executive will also be responsible for the inspection and the corrective maintenance of the device as well as for the changes in the air flow adjustment

Download Pdf Manuals

image

Related Search

Related Contents

Jarden BFH2242M-SM space heater  Samsung 2,1 Ch Soundbar H550 Brugervejledning  Pobierz - Victus  Benq Presentation Plus  mipan SI - microSYST Systemelectronic GmbH  Service Manual  lnt-6, nouveau constituant des corps nucléaires - iPubli  Leaflet 42PUS7809_12 Released France (French) High  Manuale di installazione e manutenzione Elettrovalvole (a 3  MODELO INTERNO Grupo 16 MANUAL DE INSTALAÇÃO  