Home
MS6460 Laser Distance Meter
Contents
1. l Single measurement Note In harsh environments such as too strong sunshine too large ambient temperature fluctuation weak reflection effect of reflective surface low battery measurement result would have large error 17 MASTECHE Daily maintenance of meter e Do not place the meter in hot and humid environment to store for long time If the meter is not used for long time please remove the battery and place the meter into the included meter case in a cool and dry place e Keep the meter surface clean Use soft damp cloth to wipe dust on the surface Don t use corrosive liquid to clean the meter Laser device window and focus lens can be cleaned according to the method for cleaning optical device MASTECHES Packing list When purchasing the meter please carefully check the following list to see whether all attachments ofthe meter are complete 1 Mainengine Po 1 2 Portable bagofmeter Pc 1 4 AAABattery Po 3 5 UserManual Po 1 6 CertificateofApproval_ Pc 1 HYS006887
2. MAS TECH mss46o0 Laser Distance Meter User s Manual MASTECHES A CE 42 Safety Regulations Please read carefully safety regulations and guidance beforeinitial use Before using the meter please read all instructions and safety regulations in this manual carefully It may result in meter damage affecting the measurement accuracy body injury to the user or others without following the operation methods in this manual Do not open or repair the meter by yourself in any way Do not retrofit illegally or change meter laser transmitter performance Please keep the meter properly do not place it in places where children may touch avoid being used by unrelated persons MASTECHas Don t make the meter s laser device radiate eyes or other body parts of you or others Don t make the laser device radiate high reflective object surface A Electromagnetic radiation of the meter may interfere with others equipments and devices Do not use it nearby aircraft or medical equipment Do not use it under flammable and explosive environment If the meter has any quality issue or you have any doubt on the meter please contact your local dealer or Sndway factory we will solve for you as soon as possible MASTECHES Install battery display and keyboard Install and replace battery e Open battery door at the back of the meter put into battery in accordance with correct p
3. Length Press key to measure the second edge Width The meter will automatically make area calculation the result will display in the main display area MASTECHES Press key to clear the previous result measure it again Area measurement Press key 7 will display on the screen one edge of cube is flashing complete the following operations according to prompts Press key to measure the first edge Length Press key to measure the second edge Width Press key to measure the third edge Height The meter will automatically make volume calculation the result will display in the main display area Press key to clear the previous result measure it again MASTECHE Indirect measurement with Pythagorean theorem In the meter there are three default modes to measure single distance of triangle with Pythagorean theorem Users can make indirect measurements easily in specific complex environment can be used for mode selection 1 Press lt key On the screen lt 1 hypotenuse is flashing Press key measure the length of the hypotenuse with dotted line according to prompts on the screen a Press key to measure the length of the leg with dotted line b The meter will automatically calculate the length of the leg with solid line x MASTECHES 2 Press lt key twice On the screen erect side is flashing Press key measure the length of one of legs with dotted line acco
4. inverse cumulative measurement mode Difference value of the last measurement value and the current measurement value will display on the screen 13 MASTECHES Store and browse Store recordings If the current data is valid in the measurement mode long press key for 3 seconds the current measurement data will be automatically stored in the meter memory MS6460 can store 20 pcs at most Browse recordings Short press key to search the stored measurement data use key or key to move forward or backward for browsing Or long press to clear all stored recordings 14 MASTECHES Prompt messages In the course of using the meter the following messages may displayinthe main display area Measure target point with strong reflectance capacity Measure target Err2 Too strong signal point with poor reflectance capacity Too low battery Err Too poor signal f Use the meter under Out of operating a Err4 temperature range the specified environment Pythagorean measurement violation Measure again to ensure that the hypotenuse is greater than the leg Please contact with 15 MASTECHES Technical parameters CE ES Maximum measurement accurac measurement function Area measurement function Present Volume measurement function Present Pythagorean measurement function Full mode measurement functions Laser grade CTC O MASTECHES
5. n be chose on the meter 05 MASTECH Length Area Volume 0 000m 0 000m 0 000m 0 00ft 0 00ft 0 00ft 0 00ft 0 00ft Backlight setting Press key MENU UNIT will display on the screen press key again ON OFF will display on the main display area of the screen key can be used for turning on off the backlight long press key to save and quit current setting press to quit the setting mode Backlight is on by default MASTECHES Measuring basis setting Press key to exchange front basis and end basis itis end basis by default Distance measurement area volume Pythagorean indirect measurement add subtract function Single measurement In the Test mode press key to radiate laser lock measurement point Press key again for single distance data measurement measurement result will display in the main display area 07 MASTECHeo Continuous measurement In the Test mode long press key to enter the continuous measurement state the maximum measurement value and the minimum measurement value will display on the screen during the continuous measurement Current measurement value will display in the main display area short press key to quit the continuous measurement mode Area measurement Press key P will display on the screen one edge of rectangular is flashing complete the following operations according to prompts Press key to measure the first edge
6. olarity of the meter then close the battery door e Only 1 5V AAA alkaline battery can be used for the meter e When the meter is not used for a long time please remove the battery to avoid the battery corroding the meter s main engine 03 MASTECHE Display Battery power indication Store data view stored data Backlight indication Auxiliary display area Measurement unit indication Laser transmitting LEE MENU UNT IBBBBEB on Maximum indication Indication for area volume Pythagorean theorem and indirect measurement Main display area Key Turn on and measurement key Pythagorean indirect measurement key Storage read storage key Area and volume key Measuring base selection key Turn off and clear key 04 MASTECHES Turn on meter menu setting Turn on and off meter In the Off mode press key the meter and laser will start at the same time the meter enters test mode In the On mode long press key for 3 seconds to turn off the meter The meter will automatically turn off if there is no any operation within 150 seconds Unit setting Press key MENU and MENU UNIT will display on the screen There are four units for choice from UNIT key can be used for MENU UNIT mode Under the MENU long press key to save current setting and quit setting state Or press key to quit setting state The following units ca
7. rding to prompts on the screen a Press key to measure the length of another leg with dotted line b The meter will automatically calculate the length of the hypotenuse with solid line x I a I i b 3 Press lt three times On the screen hypotenuse is flashing Press key measure the length of one of hypotenuses with dotted line according to prompts on the screen a MASTECHeo Press key to measure the length of the hypotenuse with dotted line in the figure b Press key to measure the length of another hypotenuse with dotted line in the figure c The meter will automatically work out the length of the leg with solid line x In the Pythagorean measurement mode leg length should be less than hypotenuse length the meter would calculate otherwise the device will show error signal prompt MASTECHES In the Pythagorean measurement mode to ensure measurement accuracy it should ensure to measure from the same starting point and measure in hypotenuse leg order Add subtract measurement function Cumulative or inverse cumulative operation can be done for single distance measurement with add subtract operation Press key will display in the main display area enter the cumulative measurement mode Accumulated value of the last measurement value and the current measurement value will display on the screen Press key will display in the main display area enter the