Home

User Manual

image

Contents

1. www scintex com au sales scintex com au SCS3MT080 SCS3MT100 SCS3MT120 SHDHS1500 amp SPLS1000 User Manual Copyright C Scintex www scintex com au sales scintex com au Technical Data Working Temperature 5 to 35 C Storage Temperature 25 to 50 C Stainless Steel Casing IP67 moisture proof water proof dustproof Power Supply Rechargeable battery DC 6V 4Ah or Transformer or Adapter 100 240V DC 12V 500mA Important Information Please read the manual carefully before use 1 Do not use these scales in areas with excessive water Do not spray water directly onto the monitor clean with a damp rag Do not overload the scales 3 Keep the scales away from high temperatures and damp conditions If the scale is not going to be used for some time please disconnect the monitor and store away from moisture 5 Ifthe monitor is stored please recharge the battery every 2 3 months to ensure its longevity Preparing To Use The Scales 1 Place the platform on a level surface away from vibrations for the most accurate readings 2 Adjust the levelling feet if present 3 Where possible avoid using in direct sunlight or near air conditioning vents 4 Ensure that no weight is on the scale when the scale is turned on 5 The scale will go through a quick LCD display test and re zero when ready for use 6 Please note that when the battery indicator d is illuminated the internal battery needs charging Powe
2. indicator will power off automatically if there are no changes in weighing value and no operation on the keyboard By setting to 0 will mean there is no automatic power off Press PRINT to select then press MODE to confirm the selected preset time Setting the Buzzer After setting the automatic power off the indicator will display or bP OFF Press PRINT to select on or off Press MODE to confirm Note using the buzzer will consume more battery power Setting the Back Light After setting the buzzer function the indicator will display bAn XY X means the backlight mode as follows X 0 means no backlight X 1 means manual mode Pressing Mode turns the back light on or off X 2 means automatic backlight function mode 1 The back light will be on whenever there is a weight on the scales X 3 means automatic backlight function mode 2 The back light will be on whenever there is a weight on the scales but will turn off after 10 seconds Y means Stand by mode Y 0 means the indicator will not show the Time amp date when in standby mode Y 1 means the indicator will show the Time amp date when in standby mode Press M amp PRINT to select the value Press MODE to confirm Setting High amp Low Check Points After setting the back light function the screen will display XXXX HI Copyright C Scintex www scintex com au sales scintex com au The indicator has a weight check point funct
3. weight will show on the screen Step 4 Load the calibration weight onto the scale for example 20kg After a stable indication displays press M PRINT amp PRINT to input the weight 20kg NOTE The calibration weight must be at least 10 of the total capacity of the scales For example for 3000kg Cattle Scales a calibration weight of at least 300kg must be used Step 5 will display on the screen after step 4 indicating the scale has entered into calibration and weighing mode Step 6 If 20kg displays on the screen it denotes consistency with the calibration weight If the value differs from 20kg or the calibration weight then please recalibrate again Step 7 Offload the weight A stable reading of 0 00kg will be displayed showing no weight is on the scales Step 8 The scale will return to weighing mode after calibration is finished Copyright C Scintex www scintex com au sales scintex com au Configuration Settings Note Ensure the circuit breaker jumper is in the ON position Entering Setup Press and hold TARE until CAL SP is displayed on the screen Press MODE to enter into setup mode and will display Press M Print to enter the menu Weight Division The screen displays Id X XXX d is the division for range display Press M amp PRINT to change the division Press MODE to confirm and proceed to the next step Display Resolution The screen displays n XXXX The value shown is
4. etting the Serial Protocol The screen displays AdS XX XX values decide the serial protocol 1 XX 99 Indicator will not send out weight data unless M or PRINT is pressed in normal weighing mode 2 XX 01 98 Indicator will send out data after receiving command 3 XX 00 Indicator will send out continuous data automatically to 10 times per second Press M amp PRINT to input the value of resolution Press MODE to confirm value and enter in to the next step Setting the Output Format for the Serial Protocol The screen displays or rS LO For example The reading weight is 15 00kg When set rS HI the output willbe 15 00kg When set rS LO the output willbe gk00 51 Press M amp PRINT to input the value of resolution Press MODE to confirm value and enter in to the next step Weight Response Speed Filtering The screen displays bUF AB A It means the response speed when weighing Speed increases by number 0 is the fastest 4 is slowest B It means filter strength when weighing Strength increases by number O is minimum 3 is maximum Copyright C Scintex www scintex com au sales scintex com au Press M amp PRINT to input the value of resolution Press MODE to confirm value and enter in to the next step Animal Weighing Hold Function Setting The screen displays FLt X There are 6 degrees of weighing mode X 0 is normal mode wi
5. ion which allows the monitor to be triggered at a high and low weight Step 1 When XXXX kg amp indication is showing set the high weight If the scale is over this weight HI will show on the screen and the buzzer will sound Set the high weight by pressing M amp PRINT to set then press MODE to confirm Step 2 When XXXX kg amp indication is showing set the low weight If the scale is under this weight LO will show on the display and the buzzer will sound Set the weight by pressing M amp PRINT to set then press MODE to confirm Setting Auto Shutdown Protection for Low Battery After setting the high low points it will display PLO XX XX means Percentage of battery capacity When the capacity of battery is lower than the setting value the indicator will shut down and need to be charged This increases the life of the battery Default is 20 Press PRINT to select and press MODE to confirm Scale Calibration Note Ensure the circuit breaker jumper is in the ON position Step 1 Press and hold TARE for 1 5 second indicator will display CAL SP Step 2 Press M to enter calibration mode CAL 0 which denotes that there is nothing being weighed on the scale will display on the screen Make sure there is no weight on the scale at this point Step 3 Press MODE to enter mode of automatic zero correction and will display After a few seconds the previous calibration
6. ng mode Press to confirm the setting when it is in set menu or calibration mode For recalling and printing out the accumulative weight Accumulative time and weight will display on the screen for 1 5 second respectively Press zero to clear M Print accumulative weight and time Selective key when in settings menu Press the key to print out the current weight and the weight will be added up to mulative weigh PRINT accumulative weignt Selective key when in settings menu Copyright C Scintex www scintex com au sales scintex com au Changing the Jumper Position For normal operation the circuit breaker jumper should be in the OFF position For more advanced features such as setting the calibration the jumper should be in the ON position To adjust the jumper open the monitor by undoing the 8 screws at the back Carefully remove the back of the casing Inside you will see a small black jumper which can be moved between ON and OFF SU LE P3 P2 P SND OFF ON ce La BIOOO OO 19 api afin y i od N HC Copyright C Scintex www scintex com au sales scintex com au General Functions NOTE The circuit breaker jumper should be in the OFF position to perform these functions Setting Automatic Power Off Press and hold ZERO for 2 seconds the screen will display OFF XX XX refers to preset shut down time There are 7 choices for preset shut down time 10 20 30 50 60 and O minutes The
7. r Supply amp Charging The scale will power off automatically when the battery is flat Monitor the battery displayed as the monitor powers off A Red charge light will also indicate a flat battery Make sure to always fully charge the monitor Never partially charge the battery as it will reduce the battery lift To charge remove the plastic plug at the rear connect the charging cable to the monitor and charge using a power socket The charge light will be lit Yellow when the battery is charging This will turn Green once the battery is fully charged DO NOT leave a charging battery unattended LCD Display Symbols Stable indication gras Battery capacity indication Net weight indication Gross Weight indication a WT 0 Copyright C Scintex www scintex com au sales scintex com au HI OK LO Check weighing indication Animal weighing Counting function kg Ib t g PCS Weigh units Face Panel Function Bat Stable Gross et Tare Zero Charge Turn on off The indicator will be turned on when pressing the key Press and hold the key for 1 5 seconds the battery charge percentage bpt will show on the screen then the indictor will power off Deduct the container weight Press this key to deduct container weight and net gt i nn weight indication will display To re zero the scale Range of re zero is 2 of full scale Weigh unit switching or selecting the backlight mode while in weighi
8. the display resolution Display resolution division kg full capacity kg Ignore the decimal point shown and take the value as a whole number Example take n 060 00 as 6000 take n 120 00 as 12000 Press M amp PRINT to input the value of resolution Press MODE to confirm value and enter in to the next step Note Please calibrate the scale again after changing Division and Display Resolution settings Zero Range Zero Tracking Range Weight Unit Setup The screen displays Ut ABXY A Zero range when power is on 1 9 means 10 90 FS to zero O0 means not to zero the scales B Zero tracking range 1 9 means 1 9 x 0 3d for tracking range X Basic unit It displays the basic and default unit after the indicator power is on Y Second unit It means switching the units from the basic unit to the secondary unit by pressing MODE When XY are set to the below value it will be a different function 00 kg only 01 kg Ib switching 10 Ib kg switching 11 Ib only 22 tonly 33 HL only On Standard weighing mode Counting mode switching Copyright C Scintex www scintex com au sales scintex com au Press M amp PRINT to input the value of resolution Press MODE to confirm the value and progress to the next step Setting the Baud Rate The screen displays bt XXXX Press PRINT to select from 2400 9600 and press MODE to confirm and progress to the next step S
9. thout an animal lock time X 1 5 is the animal weighing mode This changes the time to take a stable reading Press M amp PRINT to input the value Press MODE to confirm value and enter in to the next step Changing LCD Screen Brightness The screen will display LCD X X is the brightness with 5 being the brightest Press M amp PRINT to input the value Press MODE to confirm value and enter in to the next step Outlay Display Option The screen displays Plo X It means the option is On or Off When connecting with one display set X 1 If no display needed set X 0 Press M amp PRINT to input the value of resolution Press MODE to confirm value and enter in to the next step Configuration The screen will next display CF X X should be set to O in all cases Confirm Settings The screen displays PASS It is the final confirmation of the configuration settings Press MODE to repeat settings from beginning Press ZERO to confirm the configuration and exit to normal weighing mode Copyright C Scintex www scintex com au sales scintex com au Error Signals Error 1 Calibration is incorrect or not working Weight is too low or division is too high Error 2 Zero is wrong Check load cell for impediment or damage Error 3 Displayed value exceeds the display range after unit change H Overload the loaded weight exceeds the full range Copyright C Scintex www scinte
10. x com au sales scintex com au

Download Pdf Manuals

image

Related Search

Related Contents

annexe i : le système corail - Page Personnelle de Antonio Balvet  manual do usuário    CLUB3D CGAX-795713 AMD Radeon HD7950 3GB graphics card  INSTALLATION MANUAL MANUEL D`INSTALLATION  CANICALM FIRST NEW.indd  850 808 samson - Ronnoco Sales Ltd.  THOR BEAUFORT² MANUAL V2    le stephanais N°17 - Amazon Web Services  