Home
Alarm Handling Manual
Contents
1. 4509 It is not allowed to change the system id when changing the sys tem id range Please do not change the system id 4510 4510 It is not allowed to modify the system id when a system id exists already Confidential and Proprietary Information of ZTE CORPORATION 211 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations ZTEDH Please do not change the system id 4511 4511 The external metric type cannot be set as always default notify route Please check whether the input parameter is correct 4512 4512 The narrow sense metric type range is 0 63 Please check whether the input command parameter is correct 9001 5001 The TCP connection does not exist Please check whether the input command parameter is correct 9002 5002 The TCP connection used by BGP cannot be cleared This is the system prompt 9003 5003 The TCP connection is not set up Please check whether the configuration is correct and whether ACL blocks the TCP connection 212 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recom
2. 28418 28418 5 The used AAA method is not defined Please check whether AAA method name is wrong or define a new AAA method list Confidential and Proprietary Information of ZTE CORPORATION 119 ZXR10 Alarm Handling Manual Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations ZTEDH 28419 28419 5 The type of AAA method list is wrong Please use the correct AAA method list configured for the service type 28421 28421 5 The specified server group is not defined Please check whether server group is correct or define this server group 28422 28422 5 Server members are not configured in server group Please configure at least one member for the server group 28423 28423 5 NAS detects an unknown attribute Please check whether the server configuration attribute value pair is wrong and whether the attribute value pair is supported by NAS 28429 28429 5 AAA fails to apply for memory space Please check whether system memory utilization reaches the max and whether system configuration information reaches or exceeds the threshold if it does consider upgrading the d
3. Add entry failed event list Ys has been deleted s event list name Alarm occurred An alarm 29957 level 6 occurred at 00 08 59 01 01 2001 UTC sent by UPC MPU MIX Add entry failed event list myEvent has been deleted When the system restores the relative sub event to the event list the event list has been deleted G series ZXR 10 6900 8900 N A 29958 29958 6 Available ProcessingErrorAlarm 5 This alarm may occur when plugging in or plugging out NPC When plugging NPC the event total number already reaches the upper threshold After plugging in NPC it tries to restore interface re Confidential and Proprietary Information of ZTE CORPORATION 123 ZXR10 Alarm Handling Manual Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level ZTEDH lated sub event list Now the member number is full and this alarm appears It is a prompt There is no need to care about it Add entry failed event list s has too many items s event list name Alarm occurred An alarm 29958 level 6 occurred at 00 08 59 01 01 2001 UTC sent by UPC MPU MIX Add entry failed event list myEvent has too many items When the sys
4. 24322 24322 6 Configure STPROOT protect on the port instance or the port in stance receives superior BPDU packet Check the configuration on the switch connected with this port Set the instance priority a little higher 24323 24323 6 Delete STPROOT protect on the port instance or the port instance receives inferior BPDU packet N A 24327 24327 6 110 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Chapter 2 Alarm Message None Communication Alarm 5 After the rack enables STP enables BPDU tranparent transmission After BDPU transparent transmission is enabled STP can t be en abled Other protocols need to be configured to avoid loop other wise it will cause network storm It is not recommended that both STP and BPDU message trans parent transmission are enabled at the same time unless special requirements mst storm spanning tree transparent enable please avoid boardcast Example An alarm 24323 level 6 occurred at 16 43 07 11 10 2008 UTC sent by MEC 1 STP mst spanning tree transparent enable please avoid boardcast storm After BDPU transparent transmission is enabled STP can t b
5. 94 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Default Severity Level Cause Recommended Operations Message No NM Level Cause Recommended Operations Message No NM Level Cause Recommended Operations Message No NM Level Cause Recommended Operations Chapter 2 Alarm Message VRRP Alarm 22016 22016 6 vrrp status switchover notice Please check whether the status switchover is normal If not copy the alarm information and contact ZTE maintenance staff MAC Alarm 22784 22784 6 MAC address reaches to the MAC quantity limitation set at port Please check the port MAC address quantity settings If it alarms with 22785 alternately then check if loop exists 22785 22785 6 After MAC address reaches to the MAC quantity limitation set at port it is lower than the set quantity limitation Please check port MAC address quantity setting and check if any body attacks balefully if it alarms with 22784 alternately then check if loop exists and if anybody attacks balefully 22786 22786 6 Fail to write driver MAC address If fail to write driver continuously shut it down please and check if the hardware is connected well Confidential and Proprietary Information of ZTE CORPORATION 95 ZXR10 Alarm Handling Manual Message No NM Level Cause Recommended Operations Message No NM Level Cause Recommended Operations M
6. Cause Recommended Operation Message No Default Severity Level Cause Recommended Operation Message No Default Severity Level Cause Recommended Operation Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Related Alarms Recommended Operations Chapter 2 Alarm Message 18191 18191 6 Fail to insert route Check whether the routing table exceeds the maximum quantity of running route items and whether the parameter configuration related to route is proper 18192 18192 6 Fail to distribute route memory Check whether the route parameter configuration is correct and proper 18193 18193 6 Delete nonexistent routes Check whether the router running is normal and all parameter con figurations are correct 18195 18195 6 Unavailable QoSAlarm 5 The VPN Route Limit function is set not the warning only For example in vrf configure mode configure maximum routes 4 75 When a new routing is added to vrf the current route items reaches the upper limit of the maximum the first parametert such as 4 then the alarm occurs The new routing can not be added The alarm 18196 may occur before this alarm Increase the routing maximum threshold according to the circum stance Reduce the alarm Configure Vpn route limit fuction for Confidential and Proprietary Information of ZTE CORPORATION 69 ZXR10 Alarm Handling Manual A
7. Chapter 3 Command Configuration Error Prompt Messages Please try again later 6056 6056 Add channel ingress incorrectly Please try again later 6057 6057 The resources do not exist Please check whether the system is running normally whether the input parameter is correct and whether the equipment to monitor is running normally 6058 6058 The function is enabled This is the system prompt 6059 6059 The index exists already This is the system prompt 6080 6080 Ethernet statistics index number error Confidential and Proprietary Information of ZTE CORPORATION 219 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH Please configure correct command 6081 6081 Ethernet history control index number error Please configure correct command 6082 6082 Alarm index number error Please configure correct command 6083 6083 Host control table index number error Please configure correct command 6084 6084 The highest N host table index number errors Please configure correct command 6085 6085 Matrix control table index number error Please configure correct command 6086 6086 Fil
8. DHCP auto download configuration file retry fails 39 59 69 16924 16924 3 Available QOS Alarm 3 The utilization ratio that process uses CPU resource reaches de fined high threshold Response to operation may be slow 1692516926 It is normal that CPU resource is consumed too much in a short time Use the show task detail command to view the utilization ratio that process uses CPU resource Task s current CPU load is d 02d exceeds the highest Threshold d The first s is process name type The first d and second d are peak value of utilization ratio that process uses CPU resource The third d is high threshold that process uses CPU resource Alarm Generated An alarm 16924 level 3 occurred at 00 52 07 01 01 2001 UTC sent by UPC MPU 1 OAM Task ACL current CPU load is 60 0 exceeds the highest Threshold 55 Alarm Recovery An alarm 16924 level 3 cleared at 00 53 07 01 01 2001 UTC sent by UPC MPU 1 OAM Task ACL current CPU load is 50 0 under the highest Threshold 55 The utilization ratio that process uses CPU resource reaches de fined high threshold 6989 16925 16925 4 Available 50 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Type NM Level Cause Influence Related Alarms Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Message No Alarm Recovery Default Security Level Alarm Type NM Le
9. Default Severity Level Cause Chapter 2 Alarm Message Check whether the network status and TCP connection are normal 18452 18452 4 TCP receives the packets with offset error Check whether the network status and TCP connection are normal 18453 18453 4 TCP receives the packets with tty security check failure Check whether the TCP connection reaches the maximum setting value 18455 18455 4 TCP sends allocate packets incorrectly Check whether the network operation and TCP connection are nor mal 18456 18456 7 TCP sends the packets with incorrect IP versions Check whether the remote IP address and TCP connection are nor mal 18457 18457 6 TCP fails in closing nonexistent connections Confidential and Proprietary Information of ZTE CORPORATION 73 ZXR10 Alarm Handling Manual Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause ZTEDH Check whether the TCP connection is normal 18458 18458 3 TCP fails in closing connections in error status Check whether the TCP connection is normal 18459 18459 4 TCP retransmits allocate packets incorrect
10. The item in ON state currently will not take effect when the alarm occurs Reduce the number of entries whose state are ON for which we can set the states of entries not needed to OFF and re set the state of specific entry to ON Too many security access entities are enabled For example An alarm 21774 level 5 occurred at 00 08 59 01 01 2001 UTC sent by Stack Slave DevId 2 ACL Too many security access entities are enabled Multiple security access entries are in ON state on a non stack master device ZXR10 59 52 series 21775 21775 ProcessingErrorAlarm 5 Error occurs when doing Securityaccess operation It s a prompt used when operation error occurs on a non stack master device in stack system The current operation is invalid Retry delete partial entries whose states are ON or set them to OFF and retry Security access bind ip and mac error at driver Alarm occured An alarm 21775 level 5 occurred at 00 08 59 01 01 2001 UTC sent by Stack Slave DevId 2 ACL Security access bind ip and mac error at driver The drive operation is error on a non stack master device ZXR10 59 52 series 21776 21776 5 Confidential and Proprietary Information of ZTE CORPORATION 93 ZXR10 Alarm Handling Manual Alarm Type NM Level Cause Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Severity Level Alarm Type NM Level Cause
11. ZTEDH Please check whether the command configuration sequence is proper and the command configuration is correct 8909 8909 The command frame relay encapsulation is not run Please run frame relay encapsulation command first 8910 8910 The interface does not support frame relay This is the system prompt 8911 8911 frame relay LMI debug is closed This is the system prompt 8912 8912 The frame relay packet debug is closed This is the system prompt 8913 8913 The frame relay LMI debug is opened This is the system prompt 8914 8914 240 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages The frame relay packet debug is opened This is the system prompt 8915 8915 It cannot ser DTE value for FR DCE Please check whether the command configuration is correct 8916 8916 It cannot set DCE NNI value for FR DTE Please check whether the command configuration is correct 8917 8917 The frame relay keep alive interval cannot exceed 30s The value will be set as 29s This is the system prompt 8918 8918 No frame relay is configured for t
12. Confidential and Proprietary Information of ZTE CORPORATION 161 ZXR10 Alarm Handling Manual Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH 233 233 Too many parameters entered Perform the configuration by following ZXR10 Router Ethernet Switch Command Manual please 235 235 Input ACL incorrectly Please input the correct command parameter 236 236 The input interface board name is wrong Please input the correct command parameter 237 237 The interface board type is wrong Please check whether the system is running normally and the con figuration command parameter is correct 238 238 The ACL number does not exist Please input the correct command parameter 239 239 Fail to set the cos queue classifications 162 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Chapter 3 Command Configuration Error Prompt Messages Please check whether the input command parameter is correct and prope
13. Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause ZTEDH Please check whether the interface physical link is stable 17425 17425 6 The route id not contained in Hello packet the interface received results in link disconnection Please check whether the interface physical link is stable 17426 17426 6 Receiving Hello packet results in link disconnection Please check whether the interface physical link is stable or the configuration is correct 17427 17427 6 Management Down results in link disconnection Please check whether the disable process operation is executed 17428 17428 6 Physical interface Down result in link disconnection Please check whether the shutdown operation is executed under the interface 17429 17429 6 Interface state change results in link disconnection 56 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Chapter 2 Alarm Message Please ch
14. Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages Please try again later 8608 8608 Fail to stop NAT board Please try again later 8609 8609 NAT board is started This is the system prompt 8610 8610 Addresses in this address pool are under application Please try again later 8611 8611 The end address is smaller than the start address Please check whether the input parameter is correct 8612 8612 The address prefix is too long Please check whether the input parameter range is proper 8613 8613 This interface is not configured as inside interface Confidential and Proprietary Information of ZTE CORPORATION 233 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No ZTEDH Please check whether the command configuration is correct 8614 8614 This interface is not set as outside interface Please check whether the command configuration is correct 8615 8615 The designated rule does not exist Please check whether the input parameter is correct 8616 8616 The designated address pool does not exist Please check
15. Severity 2 alert messages ALERTS Magnitude malfunction appears in the system and immediate action is needed Severity 3 critical messages CRITICAL Emergency condition appears Severity 4 error messages ERRORS Error condition appears Severity 5 warning messages WARNINGS The system prompts that warnings appear Severity 6 notification messages NOTIFICATIONS The normal but significant event information that the system notifies to each part and records Severity 7 informational messages INFORMATIONAL It is only an informational message Severity 8 debugging messages DEBUGGING It is the re spondse information type when the administrator debugs the system or network Alarm level includes the default and actual level The default level is the original alarm level and it is fixed Users can not modify it The actual alarm level is the one used in the process of device running which is equal to the default level Users can modify it using the command alarm level change lt a arm co de gt lt l evel gt Only alarm levels 4 8 can be modified Alarm Recovery Alarm recovery includes available and unavailable available means that a prompt will appear when this alarm is deleted unavailable means that there is no prompt when this alarm is deleted Alarm Type Alarm type includes the following six categories CommunicationAlarm ProcessingErrorAlarm QOSAlarm EquipmentAlarm EnvironmentalAlarm
16. Supported Devices Chapter 2 Alarm Message To avoid continuous switchover of master slave SFC we set a limit to the switchover When threshold is exceeded master slave switchover of SFC will stop The linecard with malfunction switchover leads to the active standby 294 alarm generated by line card out of synchronism No Pannel d SFC is exchanged to be slave because switch module is unsynchronous d SFC slot number 11 15 57 03 21 2008 UTC alarm 302 occurred Pannel 1 SFC is exchanged to be slave because switch module is unsynchronous sent by UPC MPU 1 SFC synchronization fails Master slave switchover of SFC will oc cur and alarm is sent out T64E T128 N A 303 303 6 Unavailable Equipment Alarm 5 It fails to read write card memory due to the problem of hardware The single board can not work normally The thread application on the single board may suspend due to the abnormal memory No Wait for engineer from customer service department to deal with the fault line card Pannel d NPC s data eye abnormal d line card slot number s Master slave Master slave line card 13 31 30 03 25 2008 UTC alarm 303 occurred Pannel 7 NPC mas ter data eye abnormal sent by UPC MPU 1 The thread application on the single board may suspend due to the abnormal memory read write T64E T128 T1200 Confidential and Proprietary Information of ZTE CORPORATION 25 ZXR10 Alarm Handling Manual Appendix
17. 105 LIO Dias AAA 106 ZII LIA da EU oe oe 106 2382 CNT AN 107 ZO Li bt 107 LARA o 108 PAA PA EA E devin daasetes wad ger ions keadetyer sd bke 108 MLD AlarIn cashes il oak ee ache A ek es aaa a Eei 109 DAO GS AAA edie Baud vale ec AA 109 LIO 109 STA lA MA ds 109 24320 AAA 109 24324 TE 110 DAT A amtne Saige reve nce eieied et 110 24323 Ba RS eae sO A Neda 110 LOL isthe AAA AA teed ogee 110 LOCAL ACCOUNTING Alarm ccccceceeeeeseeeeeeeeeaeeaeeaennas 111 LAB IL a E EEN 111 EDPA licita Apot 111 25344 e o a 111 DOI a 112 25349 A 112 25351 rd a Ea N AR 113 QOS Da EE E E TT 113 PASIE 1e AAE E 113 D535 Orrar av A A A 113 DORA AAA ea aa a 114 LAV PNvAlLAarM Si E TE 114 DO a ae Ee ETE ERE sebo a 114 DOOR EA Ra 114 DO NA KEE eek INAKATAA NA 114 2585s A E T E datas 114 LI A ease ees eases 115 IN 115 26369 ii A A ica 115 26370 a 116 LO a dc ed o 116 A E NT 116 LOT Dita AD A An Li Ode AS 116 LOFT AA A ae eee ah 116 DOTA AA A 117 DO a et il 117 TACACS Alarm id da 117 28 160 iii iaa 117 PAA A E T 117 28162 sieiaka sl vaia aka dausaers cusses rns EE 118 2B VOZ A A A 118 ZO IGL a an AE A ALLEE AL 118 ZO n a a A E aa tins 118 ZO VII AA AA 118 28167 iii AA AAA Ai 119 28168 ii da a io 119 PAAK T EEE Sicha digas aaehaea oa AT 119 AAA Alarme ia A As 119 284 TE Aa 119 phota ta ie MAAE A A Seeedacnkuewetes 120 2842 AA 120 ZEA 22s a een Nah ca a NO 120 DEI E RAN 120 28429 ii A A aci 120 MIX Ala MS vii td ia 121 DI A le Nie OA i
18. 12423 This service doesn t exist Create this service first 12424 12424 This subservice doesn t exist Create this subservice first 12425 12425 The interface board is not a DPI board Verify the type of the interface board 12426 12426 This Vlan interface has been bound with a DPI template Verify which Template this VLAN interface has been bound in 12427 12427 This Template hasn t bound with service Bind Template with service 12428 12428 Confidential and Proprietary Information of ZTE CORPORATION 253 ZXR10 Alarm Handling Manual Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number ZTEDH This Template has been bound with a Vlan Release the Template binding with other Vlan 12429 12429 Management IP and FTP server IP are not configured Configure Management IP and FTP server IP first 12430 12430 This IP address has been bound with other FW or DPI board Release the binding relationship between IP and other FW or DPI 12431 12431 This entry has been configured Delete this configuration first 12432 12432 This entry hasn t been configured Configure this entry fi
19. 16907 5 When QoS is applied for dynamic memory the application fails 46 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Default Severity Level Cause Recommended Operations Alarm Prototype Description Message No Default Severity Level Cause Recommended Operations Alarm Prototype Description Message No Chapter 2 Alarm Message Send the alarm message to ZTE s maintenance personnel 16916 16916 6 The ftp user logs into the device No Alarm occurred 00 02 21 01 01 2001 UTC alarm 16916 occurred OAM ftp user from 192 168 1 125 port 3549 to loacl 192 168 1 10 port 21IN OK sent by MCP 16917 16917 5 If one of the terminal executes write operation then the terminal is still in the phase of configure collection If the connection is cut down for some reason then the alarm is generated The possibility of disconnection is as follows Console telnet connection times out Other terminal execute clear tcp to delete a TCP link Please do not cut down the connection when the write opera tion is being performed If the terminal connection is cut down in the phase of configure collection then all the write operations are stopped Alarm occurred The serial port interrupts to execute write 10 52 25 06 27 2007 UTC alarm 16917 occurred 0AM Writing configuration aborted because con 0 is closed sent by UPC MP
20. 6 Fail to create BGP example If possible please delete some operations consuming resources then try again 17921 17921 6 Fail to create the protocol timer If the problem appeared during command configuration it may attempt a few minutes later 17922 17922 6 Fail to create the neighbor Please check whether the configuration is correct and proper the system operation is normal and system memory application is to system maximum value 17923 17923 Confidential and Proprietary Information of ZTE CORPORATION 59 ZXR10 Alarm Handling Manual Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations ZTEDH 6 Fail to create the neighbor timer If the problem appears during configuration it may attempt a few minutes later 17924 17924 6 BGP fails to acquire TCB for passive interception The link setup information acquired from TCP is wrong Please check whether TCP is running normally first 17925 17925 6 BGP fails to acquire TCB for active link setup The link setup information acquired from TCP is wrong Please check if TCP is running normally first 17927 17927 6 Fail
21. 68 Confidential and Proprietary Information of ZTE CORPORATION 15 ZXR10 Alarm Handling Manual ZTEHX Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Decrease the board temperature if necessary Decrease the envi ronment temperature of the equipment by the fan heat dissipation If the temperature is too high stop using the board Alarm Occurred s Panel d Current remote temperature is d C dF exceeds the second high threshold d C dF Alarm Cleared s Panel d Current remote temperature is d C dF under the second high threshold d C dF The first s is the board type the first d is the panel number of the board the second d is the centigrade temperature of the board the third d is the Fahrenheit temperature of board the fourth d is the centigrade temperature of the set threshold and the fifth d is the Fahrenheit temperature of the set threshold Alarm Occurred s Current remote temperature is d C dF exceeds the second high threshold d C dF Alarm Cleared s Current remote temperature is d C dF under the second high threshold d C dF The first s is the board type and is fixed to BIC board There is no panel number on BIC board so the display format is different from other board the first d is the centigrade temperature of the boar
22. Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Chapter 3 Command Configuration Error Prompt Messages The alarm level corresponding to the alarm ID cannot be changed Please check whether the input parameter is correct 7067 7067 Fail to write alarm log file Please try again later 7068 7068 Write alarm log file successfully Informational notice No action is needed 7069 7069 Fail to clear the content in the alarm buffer Please try again later 7071 7071 Fail to set the unified NM trap host address Please try again later 7081 7081 Error board type Please check whether the input parameter is correct 7082 7082 Confidential and Proprietary Information of ZTE CORPORATION 227 ZXR10 Alarm Handling Manual Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No ZTEDH Error port ID Please input the correct parameter 7083 7083 Error occurs when converting the panel ID to the unit ID Please try again later 7091 7091 syslog server configuring quantity reaches the maximum value Delete the redundant syslog server 8008 8008 SNMP V1 does not support the
23. Too many directory levels Reduce the directory levels 33 33 Boot upgrade is undergoing Wait please Try again later 34 34 Fail to update boot Confidential and Proprietary Information of ZTE CORPORATION 151 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH Please check whether the boot file to upgrade exists Please stop system traffic and retry when the system is idle If fail to retry many times please contact ZTE maintenance staff after recording the error 35 35 The line board to upgrade is offline Please input the correct parameters 36 36 Fail to copy of the boot file to memory Please check whether the file to upgrade boot exists Please stop system traffic and retry when the system is idle If fail to retry many times please contact ZTE maintenance staff after recording the error 3 37 Succeed in bootrom upgrade It is the prompt that system command is executed successfully no more other operation is needed 38 38 Exchange network is under boot upgrade wait please The system is carrying out the exchange network boot upgrade it is suggested that not to perform other operations Please execute them after system upgrade success 39
24. continues please contact with ZTE Corporation 18832 18832 6 Unavailable ProcessingErrorAlarm 5 When LSP pings TE tunnel the setting to option Size is so large that the size of LSP ping packet is larger than MTU of outgoing in terface where packet segmentation is needed But packet cannot be segmented when LSP pings TE tunnel Fails to send LspPing packet and prints Q LspPing can not get through Reduce the setting to option Size in LSP PING TE tunnel Alarm occured 02 09 51 11 09 2098 UTC alarm 18832 occurred IP Operation failed while fragmentize RSVP datagram sent by UPC RPU 1 Because the set option size is too big the LspPing packet is larger than the MTU of the outgoing interface RSVP packet cannot be segmented when LSP pings TE tunnel T128 T1200 Confidential and Proprietary Information of ZTE CORPORATION 81 ZXR10 Alarm Handling Manual Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Prototype Description Alarm Description ZTEDH 18833 18833 4 Unavailable ProcessingErrorAlarm 5 Invalid ippool Users can not get online Through turnning on the IPPOOL debug switch check the origin of the invalid dispo
25. 1 The authentication message received vrrp and the set authen tication message is not the same 2 SNMP configuration about vrrp sending trap is correct Check whether the packet authentication message between the main and the backup routers is the same If they need to commu nicate with each other then the authentication message must be the same vrrpTrapPacketSrc The source address of vrrp packet OID 1 3 6 1 2 1 68 1 5 0 vrrpTrapAuthErrorType vrrp authentication failure type vrrp authentication failure type VRRP_AUTH_TYPE_INVALID 1 VRRP_AUTH_TYPE_MISMATCH 2 VRRP_AUTH_FAIL 3 OID1 3 6 1 2 1 68 1 6 O vrrp TrapNewMaster Vrrp active turns into standby 1 VRRP active and standby changeover 2 VRRP priority changes Check whether the system is steady after the active and the standby changeover vrrpOperMasterlpAddr the virtual IP address when the active turns into standby OID 1 3 6 1 2 1 68 1 3 1 7 0 0 Confidential and Proprietary Information of ZTE CORPORATION 273 ZXR10 Alarm Handling Manual ZTEHX Message Description Trigger Conditions Recommended Operations Bound Variables Message Description Trigger Conditions Recommended Operations Bound Variables IPV6TRAP Information ipv6lfStateChange IPv6 interface status changes 1 IPv6 interface status changes 2 The configuration of SNMP related to Ipv6 sending trap is cor rect N A ipv6IfDescr
26. 2 1 14 16 1 4 ospfPacketType OSPF packet type hello packet IsReq packet and IsAck packet OID 1 3 6 1 2 1 14 16 1 3 ospfVirtIfRxBadPacket Fail to resolute OSPF report received at OSPF virtual interface 1 Fail to resolute OSPF report received at OSPF virtual interface 2 The SNMP configuration about OSPF trap sending is correct Please check whether the link between routers is perfect and the router configurations at two sides are consistent correct and proper ospfRouterld router ID used to distinguish the routers in au tonomous system and the value is only value OID 1 3 6 1 2 1 14 1 1 ospfVirtlfAreald the area ID crossed by OSPF virtual connection OID 1 3 6 1 2 1 14 9 1 1 ospfVirtIfNeighbor the router ID of OSPF virtual neighbor OID 1 3 6 1 2 1 14 9 1 2 ospfPacketType OSPF packet type hello packet IsReq packet and IsAck packet OID 1 3 6 1 2 1 14 16 1 3 ospfTxRetransmit OSPF report is transferred on OSPF non virtual interface 1 The report received at the OSPF non virtual interface is trans ferred 2 The SNMP configuration about OSPF trap sending is correct None ospfRouterld router ID used to distinguish the routers in au tonomous system and the value is only value OID 1 3 6 1 2 1 14 1 1 ospflfIpAddress the IP address at OSPF interface OID 1 3 6 1 2 1 14 7 1 1 ospfAddressLesslf index of interface without address O for inter face with address and ifIndex index
27. 226 Incorrect target file name path Please input the correct command parameter 227 227 The file name is too long 160 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Chapter 3 Command Configuration Error Prompt Messages Please input parameters within the range permitted by command 228 228 The source file name is the same as target file name during copy ing Please input the correct command parameter 229 229 The input date is incorrect Please input the correct command parameter 230 230 It modifies system clock incorrectly Please try again later If error appeared many times please con tact ZTE maintenance staff after recording the error 231 231 Fail in acl configuration operation Check whether the configuration reaches the maximum system permitted value and try again later If fail to retry many times please contact ZTE maintenance staff after recording the error 232 232 Fail in route map configuration operation Check whether the configuration command is correct and proper and try again later If fail to retry many times please contact ZTE maintenance staff after recording the error
28. 28 29 08 13 2008 UTC alarm 23824 occurred DHCP DHCP pool validPool not bound ippool sent by UPC RPU 2 IPPool is not configured in dhcppool All MLD Alarm 24064 24064 6 MLD multicast member joins Users can not get online N A 24065 24065 6 MLD multicast member leaves Check whether MLD configuration is correct and proper Check whether it receives MLD multicast member joining or leaving pack ets STP Alarm 24320 24320 Confidential and Proprietary Information of ZTE CORPORATION 109 ZXR10 Alarm Handling Manual Default Severity Level Alarm Recovery Alarm Type NM Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Security Level ZTEDH 4 unavailable ProcessingErrorAlarm 5 If configure STPLOOP protection for port instance after running the port instance can not receive BPDU message Users need to check whether there is something abnormal of the port or whether the topology is changed If the topology is not changed but there is something abnormal on this port then re boot the port please 24321 24321 6 Port instance configure gets rid of STPLOOP protect Port instance is blocked formerly but now it receives BPDU packet N A
29. 39 Fail to upgrade exchange network 152 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Chapter 3 Command Configuration Error Prompt Messages Fail to upgrade exchange network Check whether the boot file necessary for exchange network upgrade exists please If it exists check whether the system CPU is busy if busy try again later If fail to retry many times please contact ZTE maintenance staff after recording the error 40 40 The specified board card is offline Check whether the input command is correct please if correct check whether the board card with specified slot is operating well try again after it operates normally If fail to retry many times please contact ZTE maintenance staff after recording the error 41 41 Fail to copy file to memory Check whether system CPU is very busy or the specified file exists please If the file exists try again later If fail to retry many times please contact ZTE maintenance staff after recording the error 42 42 Succeed in exchange network upgrade It is the prompt that command is executed successfully No more other operations are needed 44 44 There is no response to overtime when writing Img image file Chec
30. 5 EnvironmentalAlarm 5 The neighbourhood is established between two ports on this de vice Check whether there is loop in the port If loop exists check whether it is necessary to remove the loop interface s and s build udld neighbour relationship s interface name the two interfaces connect with the rack di rectly 00 14 07 01 01 2001 UTC alarm 29697 occurred interface fei_1 2 and fei_1 8 build udld neighbour relationship sent by MCP The loop occurs between the two ports ZXR10 3900 6900 128 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operation Alarm Prototype Description Alarm Description Supported Device Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operation Alarm Prototype Description Chapter 2 Alarm Message 29698 29698 4 Unavailable CommunicationAlarm 4 All the neighbourhood is removed All the neighborhood is lost on this port If this interface is in UDLDAggressive mode it will activate the neighborhood detec tion If this interface can not be detected the link is regarded as monologue and sets this interface DOWN Check whether the communication between this port and the other port is normal all neighbours clear on s s interface name 00 28 40 01 01 2001 UTC
31. 7 1 9 RMON TRAP Message risingAlarm Trap The trap is sent when the monitored variable on RMON alarm table exceeds the set upper alarm limit 1 The monitored alarm variable value exceeds the set upper alarm limit 2 The trap sending is defined in the corresponding rising event control item in the alarm control item 3 The relevant configuration for SNMP sending trap is correct Please take the corresponding measure according to the influence of the monitored variable changes on the system alarmIndex alarm control table item index No OID 1 3 6 1 2 1 16 3 1 1 1 alarmVariable monitored alarm variable OID 1 3 6 1 2 1 16 3 1 1 3 alarmSampleType monitored variable value sampling type abso lute value type difference type OID 1 3 6 1 2 1 16 3 1 1 4 alarmValue monitored variable value OID 1 3 6 1 2 1 16 3 1 1 5 alarmRisingThreshold set upper threshold of monitored variable OID 1 3 6 1 2 1 16 3 1 1 7 fallingAlarm Trap The trap is sent when the monitored variable in RMON alarm table is lower than the set lower alarm limit 1 The monitored alarm variable is lower than set lower alarm limit 2 The trap sending is defined in the corresponding falling event control item in the alarm control item 3 The relevant configuration for SNMP sending trap is correct Please take the corresponding measure according to the influence of the monitored variable changes on the system alarmIndex alarm cont
32. Alarm 26385 26385 6 None Communication Alarm 5 After device or board is restarted if MP detects that ESM configu ration of line card is different from the local one MP will download ESM configuration on line card and save it The ESM configuration will be valid when line card is restarted Restart the specific board according to alarm message MP had sent configration to slot 1 and set successfully Please reload slot 1 Example 08 50 51 09 04 2009 UTC alarm 26385 occurred MP had sent con figration to slot 1 and set successfully Please reload slot 1 sent by MEC 1 If MP detects that ESM configuration of line card is different from the local one MP will download ESM configuration on line card and save it The ESM configuration will be valid when line card is restarted 69 89 Switches EPON Alarm 33280 33280 CommunicationAlarm 5 Because the attenuation of the optical path between ONU and OLT is out of normal range or ONU and OLT optical parameter config 134 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Influence Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level Cause Influence Recommended Operations Chapter 2 Alarm Message urations are not correct optical path is abnormal and the data transmission abnormality occurs on bit The transmiss
33. C dF The first s is the board type the first d is the panel number of the board the second d is the centigrade temperature of the Confidential and Proprietary Information of ZTE CORPORATION 9 ZXR10 Alarm Handling Manual Alarm Description Supported Devices 10 Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Related Alarms Recommended Operations Alarm Prototype Description ZTEDH board the third d is the Fahrenheit temperature of board the fourth d is the centigrade temperature of the set threshold and the fifth d is the Fahrenheit temperature of the set threshold Alarm Occurred s Current local temperature is d C dF under the low thresh old d C dF Alarm Cleared s Current local temperature is d C dF exceeds the low threshold d C dF The first s is the board type and is fixed to BIC board There is no panel number on BIC board so the display format is different from other board the first d is the centigrade temperature of the board the second d is the Fahrenheit temperature of board the third d is the centigrade temperature of the set threshold and the fourth d is the Fahrenheit temperature of the set threshold An alarm 63 level 5 occurred at 01 58 00 01 28 2001 UTC sent by UPC MPU 2 ENVIRONMENT SFC Panel 1 Current local tem perature is 33 C 91F under the low threshold 40 C 104F An alarm 63 level 5
34. CE amp PTN version supports this alarm 16394 16394 5 Available Equipment Alarm 5 Alarm occurred Users configure the device again after plugging the backplane The backplan backup does not complete Alarm cleared The backplane finishes the backup for the main board The back plane can work instead of the main board The backplane can not work instead of the main board Wait for a while to see whether the alarm recovers Or check whether the backplane backup the data on the main board Alarm occurred Slave is not a copy of master Slave board can not substitute for master board 14 50 22 08 20 2008 green alarm 16394 occurred ROS Slave is copying of master Slave board can not substitute for master board sent by UPC MPU 2 Alarm cleared Slave is a copy of master Slave board can substitute for master board 14 59 17 08 20 2008 green alarm 16394 cleared ROS Slave is a copy of master Slave board can substitute for master board sent by UPC MPU 2 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Description Supported Devices Message No Default Security Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Message No Default Security Level Alarm Type Chapter 2 Alarm Message The backplan backup does not complete It can not work instead of the main
35. Cause Recommended Operations Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Alarm Prototype Description Chapter 2 Alarm Message 6 When configuring ISIS aggregation if there is no additional space for ISIS LSP packet the alarm will be generated Please set parameter range 32 in command System ID 19983 19983 6 unavailable EquipmentAlarm 5 When configuring ISIS aggregation if there is no additional space for ISIS LSP packet the alarm will be generated ISIS protocol regards the interface failure The reason for interface invalid may be as follows If this interface is deleted ISIS protocol regards that this interface is invalid If ISIS can not find the corresponding physical interface then it regards that this interface is invalid If the interface encapsulation type changes ISIS regards that this interface is invalid instantly If this interface switchovers from one ISIS instance to another ISIS regards that this interface is invalid instantly This interface is up physically but ISIS does not regard it as UP For example if the interface IP address is deleted suddenly ISIS regards that this interface is invalid Notice ISIS that this interface is invalid Port s port num d change from UP to DOWN s interfacer name d interface number Port s port num d type change from s to s The first s interface name d interface numbe
36. Command Configuration Error Prompt Messages Please configure correct command 106 106 Too many Idp advertise label controls Please configure correct command 107 107 The command takes effect at the next start Reboot the device to take effect 108 108 Too many Idp password settings Please configure correct command 109 109 The mpls cannot run at the loopback interface Please configure correct command 110 110 The parameter setting is improper Please set correct command parameter 112 112 Confidential and Proprietary Information of ZTE CORPORATION ZXR10 Alarm Handling Manual Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH The hold time interval of Hello ought to be longer than Hello report interval Check mpls hello hold time interval and hello report interval please the correct configuration ought to be that hello hold time interval is longer than hello report interval 201 201 The flash is under application Please try again later 202 202 Incorrect copy type Please configure correct command 203 203 The T FTP server does not respond Check whether the line connection and server operation are nor mal 204 204 Start to copy Informatio
37. Confidential and Proprietary Information of ZTE CORPORATION 75 ZXR10 Alarm Handling Manual Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause ZTEDH 7 UDP receives the packets with wrong IP versions Check whether the network connection is normal and the system configuration is correct 18564 18564 7 UDP receives the packets with wrong checksum Check whether the network connection is normal IP Alarm 18689 18689 2 RP fails to initialize routing table If possible save the configuration and then restart the router Please contact ZTE maintenance staff after saving this message 18691 18691 4 Fail to initialize the packet buffer Check whether the router running is normal 18692 18692 2 Fail to initialize the interface connection 76 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recomm
38. E gt eereeainc ei ipa E ani a a 208 DOA A tials ea clea dita evant 209 404 Biia ei aver ad ia 209 404G niman o a ered cite tale dy cate tate oA a aaeies 209 O 209 ADA ns 209 AO PAPA EE ETE TT 209 O PEE E 210 A502 ccsretevceesvncveceeeeceeoe ever nee vaeveenes iiber e rex itni 210 BOS ie fori esate mena seas tee eat eat oe sa heen ant aetna 210 AB OF eieaa aie E A O vglvle site alee oi Sutiidwediutteai 210 a 210 O reds 211 O eine 211 A GaiscPererastdavdenarmstirtreradeibenareagy dea yemausteane ss 211 O 211 O 211 A dil ater elated hee ia Oat dia ceed Sate atti 212 AS TD cities ete il erence E nee aa 212 BOOT A vier eeicie dd eterna ae die epee ees 212 O O 212 O A ease 212 A ea dev vane ue estas ture A a T 213 A dens E E dete cieWdeneievr te 213 a OO 213 Us 213 US 214 A O 214 6020 E E E E peteenede pees 214 OO E A A A AAA 214 JA O 214 CU A ete eae 215 O A 215 NO 215 A O 215 Ut a 215 GO28 iii A A A 215 6029 iii A ET 216 AT 216 O 216 603 2 as iid OO 216 GOSS veces Sia eine eis aa were mage A 216 GOS Aisa anew ta ao aii 216 A O 217 G03 Oir cie A O evens 217 GOS y A EEE dd ARA 217 GOS 8 iii ii A A A iets 217 UA en ree ee ec 217 A kate isle a ble cats ects ialeiuce AA fe 217 6051 vinden dai ae ae a ees 218 UA do 218 UI A co 218 O 218 GOSS E ET 218 GOBO eccceive eascevioeiee ati ienn o 219 O tated 219 US A 219 Oi o 219 O A ie A el eee 219 A O 220 UL iS od 220 G08 3 ee E e E 220 Us 220 E 221 UI A unserer s 22
39. EquipmentAlarm 5 The number of MAC addresses reaches the threshold set by VLAN This VLAN can t continue learning MAC address 22794 None lt VLAN 4d gt MAC address number threshold reached svlan id Example 00 04 21 01 01 2001 UTC alarm 22793 occurred MAC lt VLAN 1 gt MAC address number threshold reached sent by MEC 1 The number of MAC addresses reaches the threshold set by VLAN 59A6989 22794 22794 6 None EquipmentAlarm 5 When the number of MAC addresses reaches the threshold set by VLAN because the number decreases the current number is lower than the number set by VLAN again This VLAN can continue learning MAC address 22793 None lt VLAN 4d gt MAC address number drop to threshold svlan id Example 00 09 10 01 01 2001 UTC alarm 22794 occurred MAC lt VLAN 1 gt MAC address number drop to threshold sent by MEC 1 Confidential and Proprietary Information of ZTE CORPORATION 97 ZXR10 Alarm Handling Manual Alarm Description Supported Devices Message No Default Security Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Appendix Specification Message No Default Security Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype Alarm Description Supported Devices ZTEDH The nu
40. Influence Recommended Operations Alarm Prototype Description Alarm Description Supported Devices ZTEDH ProcessingErrorAlarm 5 When adding a security access entry we find that the same entry has existed Generally this alarm will not occur It s a prompt used when operation error occurs on a non stack master device in stack system Retry with another security access entry name if this problem still exists it s an internal processing consistency problem and please contact ZTE engineer The same security access entity already exists Alarm occurred An alarm 21776 level 5 occurred at 00 08 59 01 01 2001 UTC sent by Stack Slave DevId 2 ACL A same security access entity already exists When adding a security access entry we find that the same entry has existed ZXR10 59 52 series 21777 21777 5 ProcessingErrorAlarm 5 It is abnormal when operating on security access entries and this alarm will not occur generally It s a prompt used when operation error occurs on a non stack master device in stack system The current operation will not take effect It s an internal processing error Please contact ZTE engineer Some error occurred Alarm occurred Example An alarm 21777 level 5 occurred at 00 08 59 01 01 2001 UTC sent by Stack Slave DevId 2 ACL Some error occurred It is abnormal operating on security access entries on a non stack master device in stack system ZXR10 59 52 series
41. Isolate Unit d Times d At Tick d On s s Panel d The first Yd slice memory queue type the range is from 2 to 30 The second d isolated times the maximum is 256 The third d tick value in this isolation The first ssingle board type the value is RP MP SP or NP The second s single board master slave type master is M slave is S The fourth dpanel number of single board Example 18 28 05 10 17 2008 UTC alarm 16396 occurred ROS Slice Isolate Unit 3 Times 1 At Tick 15628 On RP M Panel 1 sent by UPC RPU 1 Slice memory check fails T1128 T600 T1200 device This alarm can be available from V4 8 20 DATABASE Alarm 16640 16640 3 Database writing is wrong Check whether the system is running normally If it occurrs in system configuration it may try again a few minutes later 16642 16642 6 The alarm buffer only has 20 space left If it does not configure to send alarm messages to external server in ftp or syslog mode please check if there is any important alarm 42 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Chapter 2 Alarm Message message in alarm buffer by using show log
42. Message No Default Security Level Alarm Type NM Level Cause Influence Chapter 2 Alarm Message Remote respond loopback stop fails Examples 00 16 14 01 01 2001 UTC alarm 16128 occurred ETHOAM In terface loopback respond start command failed on fei_1 1 sent by NPC 1 00 16 14 01 01 2001 UTC alarm 16128 occurred ETHOAM In terface loopback respond stop command failed on fei_1 1 sent by NPC 1 The local end starts loopback and the remote end fails to respond All series This alarm can be available from V4 8 22 16129 16129 5 CommunicationAlarm 5 Lost the message that keeps protocol success status within timer time Cause local Ethernet oam protocol status initialization Check if link and packet sending receiving in receive direction are normal and re initiate protocol negotiation Interface s localmac s peermac s The first slost link in receive direction The second s and the third ssource MAC address and destina tion MAC address Examples 00 16 14 01 01 2001 UTC alarm 16129 occurred ETHOAM In terface lost ink in receive direction localmac 00d0 d0c6 5e27 peer mac 00d0 d0c0 7d81 on fei_1 1 sent by NPC 11 Packets fail to be received on receive direction of link All series This alarm can be available from V4 8 22 16130 16130 5 ProcessingErrorAlarm 5 The local or remote configuration modification causes that the local or remote can t satisfy the modified configur
43. No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations ZTEDH No PVC Please create PVC first 1056 1056 It permits only one IP address to be configured for ATM interface Please configure only one IP address 1057 1057 The point to point network permits only one map list Please use only one map list 1058 1058 VCI 1 31 are reserved for ATM not for PVC creation None 1059 1059 The input vcd already exists Confirm that the input parameter is correct 1060 1060 PVC is used by other interface Please check whether the input parameter is correct and whether the command configuration is proper 182 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages 1061 1061 This address is conflict with management interface address Please check whether the input parameter is correct and the com mand configuration is proper 1062 1062 This command cannot run at telnet terminal Refer to the
44. O 174 1KO H O O 174 O 174 DU ads 175 RO e E A O E T 175 LOA ici a EAT 175 DODD ect nn ATTE 175 LM AA 175 VOR A 176 TB A A DA 176 A NO 176 OA OEE O T 176 TO a a a a a a a a 176 LO init E RA A A A 176 TU is 177 KOPIA O aaa 177 A AT 177 1E OAS A A A A ON 177 A ped E viernes veebbv isos dbeviee decker eeu es teers 178 A ceueidivie Qe evivdeviedheWscteceverrenescueees 178 LOS 2 tase cetera ae alata ee Fa tale hale ai a E Dail aa 178 A 178 TO A AA tides 178 A ve dicen pinhead oe arene 179 A E A fee wena 179 DU opa 179 A ease deveacbersedeseverdevteuievecdeeevvrdeneeeeeees 179 LOS 9 ve csceeecce tev geveeeves oeveacv eng vevecvereevee ti ten eer ecver seers ceiees 179 TOFO n dc ta a E legate alan tent ci eet Eaa tae 179 DOA che ct CO 180 VU Ai 180 UA A tare 180 LOA4 one 180 LOAD iia 180 OO iii A O 181 LOS EEEE A 181 A tenes na cebeaeevace ve nex actives 181 A cau a tee a 181 TODS eoria E O site aieale de Suteina astetiei 181 O aces 181 TUI ia 182 A 182 A A deaseaauateerr ss 182 LOS ei A OO Do 182 A EET EEEE 182 A E ealelid Sale a atalaa 183 E cance ote 183 A O iawn es 183 LO G4 esc O evecare es 183 A ta a A uta destecerss 183 LOS Ae ci deerme ontia A aan ean eae dpa poe veab eae eetes pure 183 LOT lua De cc 184 A ice awe apnea 184 TU A A E 184 UA A OA ads 185 O O 185 OO oir A A o ei 185 PP ON 185 VII A A 185 VS OS AA 185 A hela wel tAiacamed latent etialiamedeaatiome dveeans te 186 A vee ded EAE A AERA AT
45. OMSAlarm 2 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Chapter 1 Alarm Overview NM Level NM level includes level 1 level 2 level 3 level 4 and level 5 The meanings for each level are as follows Level 1 critical Level 2 major Level 3 minor Level 4 clear Level 5 informational Cause Various kinds of causes are as follows In order to recover the system as soon as possible we should find out trigger conditions trigger frequency the resolutions and the prevent measures The causes for ZXR10 alarm messages are as follows 1 The hardware or device malfunction i Single board malfunction ii Other hardware malfunction such as system power mal funcrion fan malfunction flash card malfunction and so on iii Hardware can not satisfy needs For example current hardware such as single board CPU and the memory can not satisfy the increasing needs 2 Software malfunction It may be the software BUG or the fail ure caused by the software upgrade 3 Environment alarm For example i The smooth running of the system has a strict requirment on the environment If the temprature or the humidity can not satisfy the requirment alarm occurs ii Natural disaster and the accidental incident can also gen erate alarms For example lightening fire or earthquake 4 The configuration error or the improper setup i The setup problem the interface setup between dev
46. Operations Alarm Description Prototype Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level Cause Influence Recommended Operations Chapter 2 Alarm Message 18 57 30 08 26 2008 UTC alarm 33282 occurred EPON Epon alarm llid mismatch occour at 6000 sent by NPC 3 Time slot is wrong and ONU module doesn t forward packets in its own time slot EPON project of 4822 33283 33283 5 CommunicationAlarm 5 Detect on local OLT system mixes ONU version For example use ONU with OAM1 2 and ONU with OAM 2 0 together because ONU must apply the same OAM version in the same system Optical path is abnormal Provide the same version for the two ONU modules This alarm is called local stable alarm in EPON project In default this alarm is enabled If the alarm need to be disabled configure alarm local stable disable on OLT interface Epon alarm local stable occour Example 14 57 30 08 26 2008 UTC alarm 33283 occurred EPON Epon alarm local stable occour sent by NPC 3 Detect on local OLT system mixes ONU version EPON project of 4822 33284 33284 5 CommunicationAlarm 5 Detect on remote OLT system mixes ONU version For example use ONU with OAM1 2 and ONU with OAM 2 0 together because ONU must apply the same OAM version in the same system Optical path is abnormal Provide the same version for the two ONU modules This alarm is
47. Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages 2025 2025 The configured authentication type is illegal Please configure correct command 2026 2026 The configured protocol type is illegal Please configure correct command 2027 2027 The virtual interface does not exist Check whether the command configuration parameter is correct and whether the command configuration is proper 2028 2028 The interface name is too long Shorten the interface name 2029 2029 Fail to create OSPF example interface Check whether the command configuration is proper and correct and try again later 2030 2030 Fail to enable OSPF example interface Confidential and Proprietary Information of ZTE CORPORATION 191 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH Check whether the command configuration is correct and try again later 2031 2031 Fail to set area ingress Check whether the command configuration is correct and try aga
48. The registration that doesn t need binding mac ZXR10 config epon hardware authentication card 5 disabled ZXR10 config epon auto authentication card 5 enable 2 The registration that need binding mac ZXR10 config epon hardware authentication card 5 enable ZXR10 config epon auto authentication card 5 disabled ZXR10 config if onu 1 type ZTE F425 mac 0015 eba3 c6c9 Epon alarm onu registration error occour Example 18 41 30 08 26 2008 UTC alarm 33286 occurred EPON Epon alarm registration error occour sent by NPC 3 ONU fails to register EPON project of 4822 33287 33287 5 CommunicationAlarm 4 Confidential and Proprietary Information of ZTE CORPORATION 139 ZXR10 Alarm Handling Manual Cause Influence Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level Cause Influence Related Alarms Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Message No Default Security Level Alarm Type ZTEDH OAM link is disconnected OAM link is disconnected and can t connect ONU Check OAM link state disconnect and re connect ONU or reboot the entire rack This alarm is called oam link disconnection alarm in EPON project In default this alarm is enabled If the alarm need to be disabled configure alarm oam link disconnection disable on OLT
49. The subnet must match the subnet mask Please configure correct command 4005 4005 The subnet mask must match the subnet Please configure correct command 4006 4006 The network parameters must contain the mask Please configure correct command 4007 4007 The mask parameter must be at the network side Please configure correct command 4008 4008 The mask is too short 204 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Chapter 3 Command Configuration Error Prompt Messages Please configure correct command 4009 4009 This subnet is not a subnet of the designated network Please configure correct command 4010 4010 Illegal neighbor address Please input the correct command configuration parameter 4011 4011 Illegal protocol name Please input the correct command parameter 4012 4012 holdtime must be 0 or 3 65535 Please input the correct command configuration parameter 4013 4013 The input value is mismatched Please adjust or use the default value Please input the correct command parameter 4014 4014 Confidential and Proprietary Information of ZTE CORPOR
50. a trap type definition which is used to indicate what type the alarm is e g LinkUp LinkDown trap means link up and down alarms Moreover some traps can carry some binding variables for clearly describing the situation when alarm creating e g the ifIndex bound in LinkUp and LinkDown traps is to indicate the interface index that LinkUp LinkDown oc curred defined in RFC1213 MIB system TRAP Message coldStart The trap is sent during system power on and starting 1 The system is been powered on and started 2 The relevant configuration for SNMP sending trap is correct None Confidential and Proprietary Information of ZTE CORPORATION 257 ZXR10 Alarm Handling Manual Binding variables Information Description Triggering Criteria Recommended Operations Binding variables Information Description Triggering Criteria Recommended Operations Binding variables Information Description Triggering Criteria Recommended Operations Binding variables ZTEDH None warmsStart The trap is sent when it reloads map start during system operation 1 System applies reload command to reload map initialization or main standby switchover 2 The relevant configuration for SNMP sending trap is correct None None authenticationFailure The trap is sent when user password authentication is failed while SNMP v2 version is used to connect the equipment SNMP NMS 1 The user name and passwo
51. as micode learning and the current higig is opened by learning The learning mode can t be configured micode learning set learning mode as mac learn special lt MAC Table gt mode in micode learning please input mac learn special Example 00 43 57 01 01 2001 UTC alarm 22797 occurred MAC lt MAC Table gt mode in micode learning please input mac learn special sent by MEC 1 The learning mode is micode learning and need to be switched to learn special 6989 22798 22798 6 EquipmentAlarm 5 Permanent MAC address number reaches the upper limit can t continue configuring permanent MAC address Permanent MAC address number threshold reached dservice number Example 00 25 00 01 01 2001 UTC alarm 22798 occurred MAC Permanent MAC address number threshold reached Permanent MAC address number reaches the upper limit 59A 69 89 Confidential and Proprietary Information of ZTE CORPORATION 99 ZXR10 Alarm Handling Manual Message No Default Security Level Alarm Type NM Level Cause Influence Alarm Description Prototype Alarm Description Supported Devices Message No NM Level Cause Recommended Operations Message No Default Severity Level Alarm Recovery Alarm Type NM Level ZTEDH Loop Detect 23296 23296 4 EquipmentAlarm 5 Find the interface has a loop 1 Find interface has a loop in a vlan 2 Find interface has a loop 1 Find interface loop in vlan
52. change 1 OSPF virtual neighbor status change may be to normal direc tion or may be the status regress caused by abnormal cases 2 The configuration for SNMP related OSPF sending trap is cor rect Please check whether OSPF virtual neighbor status change is nor mal if not check whether the router system is running normally and whether the link connection is normal ospfRouterld router ID used to distinguish the routers in au tonomous system and the value is only value OID 1 3 6 1 2 1 14 1 1 ospfVirtNbrArea the area crossed by OSPF virtual neighbor OID 1 3 6 1 2 1 14 11 1 1 ospfVirtNbrRtrid the router ID of OSPF virtual neighbor OID 1 3 6 1 2 1 14 11 1 2 ospfVirtNbrState OSPF virtual neighbor status OID 1 3 6 1 2 1 14 11 1 5 Confidential and Proprietary Information of ZTE CORPORATION 263 ZXR10 Alarm Handling Manual ZTEHX Information Description Triggering Criteria Recommended Operations Binding variables Information Description Triggering Criteria Recommended Operations Binding variables ospflfConfigError Incorrect OSPF non virtual interface configuration 1 The peer parameter configuration at OSPF non virtual interface is inconsistent with the relevant configuration of the router 2 The configuration for SNMP related OSPF sending trap is cor rect Please check whether the router configurations related to OSPF protocol are consistent with the opposite end ospfRouterl
53. d is the Fahrenheit temperature of the set threshold Alarm Occurred s Current local temperature is d C dF exceeds the first high threshold d C dF Alarm Cleared s Current local temperature is d C dF under the first high threshold d C dF The first s is the board type and is fixed to BIC board There is no panel number on BIC board so the display format is different from other board the first d is the centigrade temperature of the board the second d is the Fahrenheit temperature of board the third d is the centigrade temperature of the set threshold and the fourth d is the Fahrenheit temperature of the set threshold An alarm 64 level 5 occurred at 01 58 30 01 28 2001 UTC sent by UPC MPU 2 ENVIRONMENT SFC Panel 1 Current local tem perature is 33 C 91F exceeds the first high threshold 30 C 86F An alarm 64 level 5 cleared at 01 59 20 01 28 2001 UTC sent by UPC MPU 2 ENVIRONMENT SFC Panel 1 Current local tem perature is 33 C 91F under the first high threshold 55 C 131F Board temperature is higher than the set first high temperature threshold T128 T64 T600 T1200 N A 65 65 5 Available Environmental Alarm 3 Board temperature is higher than the set second high temperature threshold The command used to set threshold for equipment temperature is temper threshold UPC master local lowthreshold 20 first high threshold 55 second highthreshold 90 63 64 Decrease board temperatur
54. dette 230 A OO 230 Oir A Ea DE 231 Oi A A 231 Oli A a cones ieee 231 A a cee tania taeda ho wlala he tiene hen ih ela hor ie 231 A E alawhvatealre te 231 9602 vs iia eee nes Aa 231 8603 veces A A A eens 232 OOO vo adieek uch Vevcusteeissess idas 232 A O eiahdeabbonvncse tat 232 PPP veeecienenees tev ede dee edveedeensei ns ried eke sevens niai 232 BGO7 E becveedee EEEE 232 DBA 233 OA 233 BOL Oeren p a a aa a a Guanes 233 A A E NEE ie EA eS 233 toL A E T E E A T 233 O at 233 tele LE ONU nev dewne edd ediwe civ T TEET 234 O D e E evens vos a cones veces 234 A O ET 234 A ised Sie tars ida seat dl tint Seals Suda utah veg Seni unas Seas 234 GOZO A E A A O st 235 A pie eebev ane ns herpes vee bv yds na chev aged eek er rey es Ceby es 235 O iii a a Dc 235 MUI AAA 235 OLA anne cn RANG aR end t me athe Late are 235 UL A eed peas 236 MULA ss 236 A E Hee veudaatreen ss 236 OL OD va ier A ca 236 A deste EEE EEEE TERET 236 Ari A ede ever reves ees 236 8705 ieor ea E aE E E a aes he nu a 237 tA ON e PET AE A T nee 237 A A E A a a 237 8708 iir a a a a a eee a vitals tate 237 OOO EAEE I E N A O ss gov teokeace warns 237 OO La 238 Oui ses teeteds veeneve cia erates everreoreteeres 238 DBA POPER A A 238 AP cee andr airinn siteve 238 BBO Gi coo esac etnias Vedic multe eat vant Yon Peau nine eee alia 238 BIO Dede cutee dic he cea i vale aatcale dela E T 238 O ees 239 O 239 A Uae diag ciua vice stat cuteGievestnae runes yee sceen eae tune 239 A
55. example first Please enable the OSPF example in global configuration 2813 2813 Confidential and Proprietary Information of ZTE CORPORATION 199 ZXR10 Alarm Handling Manual Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations ZTEDH Virtual connections exists Please delete all virtual connections 2814 2814 The same vrf does not support two examples The same vrf can only choose one example 2815 2815 Please delete all networks in this area first None 3001 3001 No RIP example is running Please check whether the command configuration is proper and correct 3002 3002 No RIP example This is the system prompt 3003 3003 It cannot create RIP example Please check whether the system is running normally and try again later 200 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages 3004 3004 It cannot enable RIP example It may
56. exceeds memory rate is alarm threshold is d Alarm Cleared 3 3f under the s M panel d current memory rate is 3 3f under the alarm threshold is d s S panel d current memory rate is 3 3f under the alarm threshold is d The first s is CPU type the first d is CPU SlotNo the first f is the current CPU utilization and the second d is the set memory utilization threshold An alarm 66 level 5 occurred at 01 47 50 01 28 2001 UTC sent by UPC MPU 2 ENVIRONMENT SP M panel 1 current memory rate is 40 562 exceeds the alarm threshold is 2 An alarm 66 level 5 cleared at 01 48 20 01 28 2001 UTC sent by UPC MPU 2 ENVIRONMENT RP M panel 2 current memory rate is 40 084 under the alarm threshold is 60 CPU utilization exceeds the set memory utilization threshold It is 60 by default T128 T64 T600 T1200 N A 67 67 5 Available Environmental Alarm 4 The remote temperature is lower than the set remote lower thresh old of the board The command used to set threshold for equipment temperature temper threshold UPC master local lowthreshold 20 first high threshold 55 second highthreshold 90 68 69 Increase the environment temperature of the equipment if neces sary Alarm Occurred s Panel d Current remote temperature is d C Y dF under the low threshold d C dF Alarm Cleared s Panel d Current remote temperature is d C dF exceeds the low threshold d C dF C
57. he vlan100 s quota 5 sent by NPC 2 DHCP access user number reaches the upper threshold ZXR10 3900 5900 6900 series switch T64E T128 T600 T1200 series router 23821 23821 4 Unavailable ProcessingErrorAlarm 5 Invalid dhcppolicy Check whether DHCPPOLICY configuration is correct enable DHCP POLICY debug to obtain more detailed information interface bound invalid dhcppolicy s s policy name configured policy not exist Alarm occurred 20 15 53 08 13 2008 UTC alarm 23821 occurred DHCP in terface bound invalid dhcppolicy invalidPolicy sent by UPC RPU 2 Invalid dhcppolicy All 23822 23822 4 Unavailable ProcessingErrorAlarm 5 Confidential and Proprietary Information of ZTE CORPORATION 107 ZXR10 Alarm Handling Manual Cause Influence Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Severity Level Alarm Recovery Alarm Type NM Level ZTEDH Dhcppool is not configured in dhcppolicy Users can not get online Please check the DHCPPOLICY configuration Enable DHCPPOLICY debug DHCPPOOL debug can obtain more detailed information DHCP policy s not bound dhcppool s policy name configured DHCPPoolis not confi
58. interface Epon alarm oam link disconnection occour Example 18 41 30 08 26 2008 UTC alarm 33287 occurred EPON Epon alarm oam link disconnection occour sent by NPC 3 OAM link is disconnected EPON project of 4822 33288 33288 5 CommunicationAlarm 4 Data loading fault or other dying gasp fault The optical path is abnormal 33290 Disconnect and re connect the connection between ONU and OLT Register ONU again This alarm is called dying gasp alarm in EPON project In default this alarm is enabled If the alarm need to be disabled configure alarm dying gasp disable on OLT interface Epon alarm dying gasp occour Example 14 57 30 08 26 2008 UTC alarm 33288 occurred EPON Epon alarm dying gasp occour sent by NPC 3 Communication over fiber is abnormal EPON project of 4822 33289 33289 5 CommunicationAlarm 140 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH NM Level Cause Influence Related Alarms Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level Cause Influence Related Alarms Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Chapter 2 Alarm Message 4 Fault occurs on the link in receive direction of local data terminal device Local receiving device is abnormal 33290 Check the link in r
59. is cor rect whether AAA configuration on NAS is correct whether in terconnection between NAS and server is ok whether network communication is normal 28161 28161 5 Tacacs client authorization queue is full Please check whether the configuration of tacacs server is cor rect whether AAA configuration on NAS is correct whether in terconnection between NAS and server is ok whether network communication is normal Confidential and Proprietary Information of ZTE CORPORATION 117 ZXR10 Alarm Handling Manual Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level ZTEDH 28162 28162 5 Tacacs client accounting queue is full Please check whether the configuration of tacacs server is cor rect whether AAA configuration on NAS is correct whether in terconnection between NAS and server is ok whether network communication is normal 28163 28163s 5 Invalid packet is received from tacacs server Please check whether the configuration of tacacs server is cor rect whether AAA configuration on NAS is correct whether shared keys configured on them are identical 28164 28164 5 Tacacs functional module is not enable
60. link forwarding is abnormal User configuration inter face is down physically Alarm cleared The board link forwarding works normally for the specified time User configuration interface is up physically User configuration interface is up down 512 Check whether the board link forwarding is normal whether the user configures this interface Confidential and Proprietary Information of ZTE CORPORATION 27 ZXR10 Alarm Handling Manual Alarm Prototype Description Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Related Alarms Recommended Operations Alarm Prototype Description Alarm Description Supported Devices ZTEDH NP d link exception cause interface s s warning d board number The first s is the interface name The second s means that the interface is enabled or disabled Alarm occurred shutdown Alarm cleared up Example 15 30 31 08 09 2008 UTC alarm 312 occurred Board link ex ception cause interface fei_9 5 shut down warning sent by NPC 9 16 36 27 08 09 2008 UTC alarm 312 cleared Board link ex ception cause interface fei_9 5 up warning sent by NPC 9 The board link forwarding is abnormal which brings to the user configuration interface down T64E T128 T600 T1200 N A 313 313 6 Unavailable Equipment Alarm 2 The forwading link on np is always abnormal and
61. mask Please input the correct command parameter 2050 2050 No backbone area Please check whether the command configuration is proper and correct 2051 2051 The backbone area is disabled Please check whether the command configuration is proper 2052 2052 Confidential and Proprietary Information of ZTE CORPORATION 195 ZXR10 Alarm Handling Manual Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH This area is not stub area Please configure correct commands 2053 2053 Unable to obtain router id Please check whether the command configuration is proper and correct 2054 2054 The stub command is invalid when it is ASBR Please refer to the related manual and input the correct command 2055 2055 This parameter is only used in BGP Please input the correct command 2056 2056 The MD5 keyword configured at the interface reaches the maxi mum value Decrease or change MD5 keyword 2057 2057 Warning The router is ASBR but it has only one stub area 196 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Caus
62. occour Example 18 57 23 08 26 2008 UTC alarm 33285 occurred EPON Epon alarm bad encryption key occour sent by NPC 3 ONU encryption key changes EPON project of 4822 33286 33286 5 CommunicationAlarm 5 The fault occurs in ONU registration process ONU fails to register Register ONU again This alarm is called registration error alarm in EPON project In default this alarm is enabled If the alarm need to be disabled configure alarm registration error disable on OLT interface 138 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Description Prototype Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level Chapter 2 Alarm Message ONU registration command examples lt s ot gt is the slot number of epon single board 1 The registration that doesn t need binding mac i hardware authentication card lt s ot gt disabled ii auto authentication card lt s ot gt enable 2 The registration that need binding mac i hardware authentication card lt s ot gt enable ii auto authentication card lt s ot gt disabled iii onu lt onuid gt type lt type name gt mac lt macAddr gt Parameter description ONU 10 type type name ONU model name ZTE D400 ZTE D402 ZTE D420ZTE D421 ZTE D422 ZTE F401 ZTE F425 ZTE F429 ZTE F430 ZTE F435 ZTE F500 ZTE F820 onu MAC address Example if epon single board is in slot 5 1
63. occurred ENVIRONMENT Fani do not work Alarm cleared 15 13 13 06 26 2008 UTC alarm 75 occurred ENVIRONMENT Fan1 restart The fan works abnormally ZXR10 3900 3200 5900 5200 UAS UAS10600 UAS10800E N A G series switch and ZX 79 79 6 Available Equipment Alarm 1 Power malfunction This leads to the abnormal working of the board 76 77 Wait for our customer service personnel to deal with the power model malfunction Alarm occurred Power errorreason s Alarm cleared s s the cause for this malfunction Power recover The content of s is New rack alarm only be applied for new rack i Current Power Module 1 fail to work 15 02 38 08 14 2008 UTC alarm 79 occurred Power er ror reason Current Power Module 1 fail to work sent by UPC MPU ii Current Power Module 2 fail to work 15 04 08 08 14 2008 UTC alarm 79 occurred Power er ror reason Current Power Module 2 fail to work sent by UPC MPU 1 iii Current Power Module 3 fail to work Confidential and Proprietary Information of ZTE CORPORATION 19 ZXR10 Alarm Handling Manual Alarm Description Supported Devices 20 Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations ZTEDH 15 06 08 08 14 2008 UTC alarm 79 occurred Power er ror reason Current Power Module 3 fail to work sent by UPC MPU 1 Old rack alarm Curren
64. power of the power supply recovers in the range of power threshold ZXR10 3928A PS ZXR10 5928 PS 30721 30721 6 None SoftProtocolAlarm 5 no response from port no response from chip no response from firmware overload Device abnormality causes that POE port power supply is cancelled POE function on the port is invalid and power supply is disabled Check device according to the prompt POE on the port is disabled PoE disable for no response from port Example 09 40 10 11 13 2008 UTC alarm 30720 occurred POE PoE dis able for no response from port on gei_2 1 24 sent by MEC 1 The port power supply status is changing The PSE power detection status is searching The PSE power detection status is deliveringPower Example2 17 52 09 06 19 2006 UTC alarm 30721 occurred POE The PSE power detection status is deliveringPower on gei_1 10 sent by MCP 1 Power supply function on gei_2 1 24 is cancelled because of no response from port 2 The power supply status on gei_1 10 becomes being in power supply Confidential and Proprietary Information of ZTE CORPORATION 133 ZXR10 Alarm Handling Manual Supported Devices Message No Default Security Level Alarm Recovery Alarm Type NM Level Cause Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level Cause ZTEDH ZXR10 3928A PS ZXR10 5928 PS ESM
65. rate ingress egress unicast multicast mpls aacll lt ac name gt lt 1 65535 gt at global configura tion mode The sampling configuration that exceeds threshold number can t take effect Delete the Netflow sample configuration that exceeds the limit Use the no netflow sample rate ingress egress unicast multicast mpls aacll lt acl name gt command to delete configuration of interface s M panel d the number of netflow configuration exceeds the limit s S panel d the number of netflow configuration exceeds the limit The first s cpu typethe first d panel number Example An alarm 29960 level 4 occurred at 09 44 55 11 29 2008 UTC sent by NPC 2 MIX The number of netflow configuration exceeds the limit The number that netflow configures on the line card exceeds the upper limit specified by system T128T1200 This alarm can be available from V4 8 22 BFD alarm 30208 30208 5 The upper layer application asks for establishing BFD session It is the prompt when BFD requests the connection It is a prompt There is no need to care about it BFD application prompt for LDP LSP 00 02 16 02 08 2002 UTC alarm 30208 occurred BFD Session LDP BFD For FEC 10 40 64 121 is CONNECT on interface fei_1 1 BFD application prompt for RSVP LSP 00 02 16 02 08 2002 UTC alarm 30208 occurred BFD Session RSVP BFD For tunnel1 is CONNECT on interface fei_1 1 The prompt for other a
66. related manuals and input the correct parameters 1063 1063 The input parameter is wrong Please check whether the input parameter is correct 1064 1064 Please unplug plug the designated interface board Please plug in and plug out the designated interface board 1070 1070 Unable to create the interface Please input the correct command parameter 1071 1071 Unable to delete the interface Confidential and Proprietary Information of ZTE CORPORATION 183 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH Please check whether the command configuration is correct and try again later 1072 1072 The vlan_id is configured already This is the system prompt 1073 1073 There are too many interfaces Please check whether the input parameter is legal and whether the command configuration is proper 1074 1074 There are many interfaces configured on the same board Please check whether the configuration is proper 1080 1080 No arp item exists This is the system prompt 1081 1081 The interface has no arp item 184 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Opera
67. to start the TCB of BGP passive interception interface Fail to start TCP for link setup Please check if TCP is running normally first 17928 17928 6 Fail to start the TCB of BGP active interception interface Fail to start TCP for link setup Please check whether TCP is running normally first 60 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Chapter 2 Alarm Message 17932 17932 6 The interface is down and the neighbor link is broken Check whether the physical interface connection is normal 17934 17934 6 Errors occur in reading the receiving buffer Delete useless TCP connections created by BGP in the means of disabling and enabling the peer to peer 17936 17936 6 The neighbor HOLDTIME is overtime Check whether the connection with the one on the opposite end equipment is normal 17938 17938 6 The state machine is wrong Check whether the connection with the butting equipment is nor mal and the system operation is well 17940 17940 6 Received report is unidentifiable Check the
68. version information of the opposite end BGP and check whether the line connection is correct and proper Confidential and Proprietary Information of ZTE CORPORATION 61 ZXR10 Alarm Handling Manual Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level ZTEDH 17941 17941 6 The report header is wrong Check the version information of the opposite end BGP and check whether the line connection is correct and proper 17942 17942 6 Incorrect OPEN report Check whether both peer to peer configuration of the opposite end is correct especially whether an authentication password is con figured 17943 17943 6 Incorrect UPDATE report Check whether the opposite end BGP configuration is correct In correct BGP configuration brings to transmitting error packets 17944 17944 6 The neighbor receives update but no resources Please check whether the system operation is normal and the system resource occupancy is in normal range After copying this alarm message system resource occupancy and system configu ration contact with ZTE maintenance staff please 17945 17945 6 62 Confidential and Proprietary Information of
69. whether the flash exists or being damaged If every thing is normal please try again later If fail to retry all the time please contact ZTE maintenance staff after recording the error 24 24 Fail to write configuration file Check whether the system operation is normal or busy Please try again when the system is idle If fail to retry all the time please contact ZTE maintenance staff after recording the error 25 25 Fail to apply for memory Check whether the system operation is normal and try again later If the phenomenon remains please contact ZTE maintenance staff after recording the error 26 26 Print and Enter None 217 27 Input illegal user name 150 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages Please input characters accord with the command specification 28 28 Input illegal password Please input characters accord with the command specification 29 29 Input illegal file name Please input characters which can form a file name 30 30 write command is executed It may try again later 31 31
70. whether the input parameter is correct 8617 8617 The host bit cannot be full O or full 1 Please check whether the command parameter is correct 8618 8618 The address pool name or address conflicts with others Please check whether the command configuration is proper and correct 8619 8619 234 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages The rule and other rule employ the same address pool or acl rule Please check whether the command configuration is correct 8620 8620 The static rule already exists This is the system prompt 8621 8621 It exceeds the maximum permitted quantity of address pools or rules This is the system prompt Please confirm that there is no conflict between the rules and the application 8622 8622 Some addresses in address pool are used by other address pool Please configure correct command 8623 8623 Address confliction exists in the address pool and static rule Please configure correct command 8624 8624 Address confliction exists in the static rule and dynamic rule Confidential and Proprietary Information of ZT
71. 0 In the manual the contents describing router are also applied to the switches with route function This manual is intended for engineers and technicians who perform operation activities on ZXR10 Router Ethernet Switch This manual describes alarm messages that may appear during the operation of ZXR10 router Ethernet switch command configura tion error prompt messages that may appear during configuration as well as TRAP messages sent by the router This manual contains the following chapters Chapter Summary Chapter 1 Alarm Overview This chapter describes the alarm message format on ZXR10 Router Ethernet Switch Chapter 2 Alarm Message This chapter describes the alarm messages appeared on ZXR10 data product including hardware alarm and software alarm Chapter 3 Command This chapter describes the error Configuration Error Prompt prompt message appeared during Messages command configuration Chapter 4 TRAP Message This chapter describes all TRAP messages sent by system Confidential and Proprietary Information of ZTE CORPORATION i ZXR10 Alarm Handling Manual ZTEHX This page is intentionally blank ii Confidential and Proprietary Information of ZTE CORPORATION Chapter 1 Alarm Overview Table of Contents CUEVA AAA 1 Alarm Glossry OVETVIEW cr einning aiaiai aa 1 Message Format Description aa 5 Overview The alarm management is responsible for gathering the malfunc tion and the event information whi
72. 01 28 2001 UTC sent by UPC MPU 2 ENVIRONMENT SFC Panel 1 Current remote temperature is 51 C 123F exceeds the low threshold 20 C 4F The remote temperature is lower than the set remote lower thresh old of the board T128 T64 T600 T1200 N A 68 68 5 Available Environmental Alarm 4 The remote temperature is higher than the set remote first high threshold of the board The command used to set threshold for equipment temperature temper threshold UPC master local lowthreshold 20 first high threshold 55 second highthreshold 90 67 69 Decrease the board temperature if necessary Decrease the envi ronment temperature of the equipment by the fan heat dissipation Alarm Occurred s Panel d Current remote temperature is d C dF exceeds the first high threshold d C dF 14 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Related Alarms Chapter 2 Alarm Message Alarm Cleared s Panel d Current remote temperature is d C dF under the first high threshold d C dF The first s is the board type the first d is the panel number of the board the second d is the centigrade temperature of the board the third d is the Fahrenheit temperature of board the fourth d is the centigrade temperature of the set threshold and the fi
73. 1 A A AE 221 OO Lei O o ias 221 MOOD eiii E EET ET TEET 221 MO A A A A E a 221 7003 rona tenets woe hla a a oe seats ate 222 Dd aeaels a ibd eaeaee lipids 222 DA a 222 O A A ecikdaleaaeres 222 A esis end doa we ntae ees ce A rene 222 TOO iii castes eave dedescvereedee ever devteddeess 222 A eecicee civ ET ETET 223 POLA 223 DA are de ceili ate aide EE 223 DU a ees 223 LO2A O 223 A E vegee n seek nena sao anne eInG eee 223 LOZ 3 sa 224 1024 iii A ARA 224 MOBO Peon cve edt decubacvetervscevieeevientrees 224 OBL ici trees ee cvewneve edie eaeen cd tenes veevee cceea sieves 224 LOB LA NS 224 O A O 224 O 225 DU ias 225 A diate clases T 225 LOS Me cuducsdcuscede A eran dattensinats tereihdebeeanves 225 7052 ii A pies bev a 225 MOB sede eviedetendevers 225 MA A viele A 226 DOI 226 Dia 226 DI ss a r E A aa 226 A EE O 226 DIA a A T 226 DO ii ada 227 O OO 227 e 227 DU eek ov Tener eet seth suena ene bev eaueeee 227 A shanties daa E ts au Abate E das pecan nes ote 228 TOOT ii RR A eke dens AO A ped tete 228 QOOB ai civ A ARA 228 A A Saw eaten ioe teak etal te 228 Oi A 228 A ON 228 O50 ies eid O O 229 O o Oi 229 A eek tan eats se gee Vea cane steak ekeh cae anes 229 B54 iii A TEETT 229 OO iii nt A A needs 229 O A 229 A tb ae Matic a eatin Gare dite ial O at ante seit teh 230 O51 Ove i see O are tea es 230 QOL sear inate el ag cutee wage A A ange edanewe uaa at 230 BOL AE each tase eee tna aaeant geudeanetesustubt stout E on aia
74. 1027 1027 The debug of arp packet is deactivated Informational notice No action is needed 1028 1028 The debug of icmp packet is activated Informational notice No action is needed 1029 1029 Confidential and Proprietary Information of ZTE CORPORATION 177 ZXR10 Alarm Handling Manual Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH The debug of icmp packet is deactivated Informational notice No action is needed 1030 1030 The host address is illegal Please input the correct parameter 1031 1031 The input address is illegal Please input the correct parameter 1032 1032 This interface is not an Ethernet interface Informational notice No action is needed 1033 1033 Fail to match the route to delete Please check whether the input parameter is correct 1034 1034 Please remove the ip unnumber attribution of interface first 178 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Messa
75. 2 Fails to send DHCP packet ZXR10 3900 5900 6900 series switch T64E T128 T600 T1200 series router 23818 23818 6 Unavailable ProcessingErrorAlarm 5 The routing of the address distributed by the DHCP Server is not matching with the routing of the interface address The user in L3 interface can not obtain the IP address Confidential and Proprietary Information of ZTE CORPORATION 105 ZXR10 Alarm Handling Manual Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Severity Level Alarm Recovery Alarm Type NM Level ZTEDH Check whether the ippool address binded by DHCP is matching with the interface address direct connection and whether there is routing to the Relay agent with relay no match route from access interface Alarm occurred 13 58 23 07 17 2008 UTC alarm 23818 occurred DHCP no match route from access interface sent by MEC 1 The routing of the address distributed by the DHCP Server is not matching with the routing of the interface address ZXR10 3900 5900 6900 series switch T64E T128 T600 T1200 series router 23819 23819 6 Unavailable ProcessingErrorAlarm 5 The L3 interface configuring DHCP Server does no
76. 2804 2804 It cannot configure NSSA area at stub Please check whether the command configuration is proper 2805 2805 It cannot configure virtual connection across the backbone areas Please check whether the command configuration is proper 2806 2806 It cannot configure virtual connection cross stub or NSSA areas Please check whether the command configuration is correct 2807 2807 The area with virtual connection cannot serve as NSSA area 198 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Chapter 3 Command Configuration Error Prompt Messages Please configure correct command 2808 2808 The area with a virtual connection cannot serve as stub area Please configure correct command 2809 2809 The backbone area cannot be configured as stub area Please configure correct command 2810 2810 The virtual connection configuration exists in this area Please delete the virtual connection configuration in the area first 2811 2811 The transmission area used by a virtual connection cannot serve as the backbone area Please configure correct command 2812 2812 Please enable the OSPF
77. 3 When the active board and standby board change over the Card Type reported by the lower layer BSP is not in the valid range Its value is abnormity This alarm is used for the location of the malfuction It has no influence on the operation or the utility 299 299 3 Available Equipment Alarm 2 Alarm occurs Device is removed from 59 stack system 22 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Related Alarms Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Related Alarms Recommended Operations Alarm Prototype Description Alarm Description Chapter 2 Alarm Message Alarm clears Device is added to 59 stack system 512 18720 18721 Check whether any device is removed from stack system Alarm occurred Remove Device No d d is device number Alarm cleared Add Device No d d is device number Example 15 50 49 01 22 2008 UTC alarm 299 cleared Board Add De vice No 3 sent by Stack Master DevId 2 15 52 13 01 22 2008 UTC alarm 299 occurred Board Remove Device No 3 sent by Stack Master DevId 2 Device is removed from stack system 59 stack system N A 300 300 2 Available Equipment Alarm 1 The double SFC MPU RPU are both active or both standby caused by hardware malfunctio
78. 3 interface name of user access Alarm occured 16 28 43 07 15 2008 UTC alarm 23811 occurred DHCP ver ifying illegal user 00 CO 0000 0001 from vlan100 sent by NPC 2 The across network section roaming switch appears in DHCP Relay or DHCP server user But the roaming switch is off ZXR10 3900 5900 6900 series switch T64E T128 T600 T1200 series router 23812 23812 6 Unavailable ProcessingErrorAlarm 5 DHCP Relay agent address is not configured in the L3 interface that the DHCP users access The user in L3 interface can not obtain the IP address Configure DHCP Relay agent address in the L3 interface to let user launch DHCP request again Use the following command routerA config if ip dhcp relay agent 200 1 1 1 relay have no valid agent configure Alarm occured 16 53 11 07 15 2008 UTC alarm 23812 occurred DHCP relay have no valid agent configure sent by NPC 2 DHCP Relay agent address is not configured in the L3 interface that the DHCP users access ZXR10 3900 5900 6900 series switch T64E T128 T600 T1200 series router 102 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Recomm
79. 32 td eee 61 V7 D3 4 iss an Me ise a 61 A A E 61 LO it A AA AE 61 L794 O AA dis 61 VD A A 62 IA Za iia 62 17943 a ia 62 1 944 A AENEAN AANTAL AAKRES 62 A E E ET 62 17946 AE E A ast iauiaesieeays 63 A EAEE E E EAE 63 Li ian rehes servant eevee 63 LO li a it 64 e e E 64 A habs vane dip Odors bs cues tegatana agate ees 64 DIO eaa a EAE E oeaeceate iN 64 A E 64 VII o o 0 65 NT TREN 65 A aan iam a ao bean ets 65 A nace vad arena ley ta TARANEE E OEE EKNE 65 AA E T 65 V7 I SE E A E E AT 66 17963 ii A AAA e A e Ad 66 W 7964 ianea a EAT pE E RS 66 DRPEAla Mid el 66 DOT O ASA 66 BT oa 66 1D 67 E A Mia inch eG Moan teen A 67 VB LB Li iii 67 A rel a E EE EAn 67 A TE E EET 68 kenketa REEE Alt 68 dose als peepee nee ran a a aa 68 18 UB Oi A eta Stelter Hive Liven Seren OO 68 O 68 A ota et aetialaees wleccoreest 69 VB 1G 22sec is OR oh Sasa Dina aah ceed Ses ah ea eae 69 A E O eons Rate abe 69 A A O 69 VEV96 ita dd ata 70 TORA a tetas mandir ive N aa 71 LA o tea e ade 71 PP ots eet ietielowee a 71 LU 71 A A T 71 E ocak ee Vana ae yoo eek ee Seeea ces 71 LOA Ti A AA Bab i et 72 Reta ho O A E A AE 72 A A T 72 LL A AA 73 A A EET 73 A oiaren oa OA RE N UR NA peis 73 A a REA REESE AEEA 73 DBAS Te iii E R T RE 73 T8458 nn a a a a eee A ate 74 A diaa aa eaoaai 74 184 60 ii vin eiaaiaviaeciavieaviciedwexseniveeeenieravexs 74 VBA A T diteae cote een wee kaeteat ess 74 18463 xin A od aie atom sian ANA 74 VB 4 64 vata howe aid
80. 68 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages Please try again later 274 274 The physical interface cannot be deleted Input a correct command please 270 275 This command cannot be used at this sub interface Refer to the related manuals and use this command in the right interface 276 276 This command cannot be used at this interface Refer to the related manuals and use this command in the right interface 2 7 277 The flash is not existed Please check whether the system is running normally and the flash device exists 278 278 The system provides the reference clock for the interface board Confidential and Proprietary Information of ZTE CORPORATION 169 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations ZTEDH None 279 279 This interface does not support a designated clock source None 280 280 This comma
81. 9 occurred BFD Session LDP BFD For FEC 10 40 64 121 is DOWN on interface fei_1 1 BFD application prompt for RSVP LSP 00 02 16 02 08 2002 UTC alarm 30208 occurred BFD Session RSVP BFD For tunneli is DOWN on interface fei_1 1 The prompt for other application 00 02 16 02 08 2002 UTC alarm 30208 occurred BFD Session 10 40 64 120 gt 10 40 64 121 is DOWN on interface fei_1 1 126 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Default Severity Level Cause Alarm Prototype Description Message No Default Security Level Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype Alarm Description Chapter 2 Alarm Message 30212 30212 5 When BFD conversation is created the number of conversation on a CPU exceeds the limit When establishing session a prompt on RP is as follows 00 02 16 02 08 2002 UTC alarm 30212 occurred BFD RPU create too many Sessions When establishing session a prompt on NP is as follows 00 02 16 02 08 2002 UTC alarm 30212 occurred BFD NPC Panel 1 create too many Sessions 30213 30213 5 ProcessingErrorAlarm 5 Establish BFD session on the interface which doesn t support it The current switch supports VLAN SUPERVLAN interface The high end router supports the following inter faces it ge4c xgel xgew vlan geit vlan ge4c vlan xgel vlanxgew qinq geit qinq ge4c qinq xgel qinq xge
82. A A 186 A T 186 ZOO Teves ta oo 186 2002 iia ceive A A A iaaii 186 PAOLO e COP O 187 LO AA Mareeba aa A 187 2005 it Peat area ari cate static Da E nati ane are du eiial Seay 187 2006 eerie eee rb OO 187 LOOT pectrces a a nue lag ewe wean aves oie tes 187 O E 188 DU io ao 188 MO Do A O ye enes 188 A A OT 188 PAO E A A A ne iets 188 DU eee de ube teeta alee ina 188 QO VA ae e leita AEE dhe tie cata AE A 189 OLS yankee ae ae OO 189 201 6 nory a A A 189 DA E 189 A O 189 LO Oui A A A a iea s 190 POPA o A e 190 A E A T EAA 190 LI A 190 A ensecpestawes a aE pee eens 190 2024 ONO 190 DU iaa 191 DU o cea 191 LO rita AA ARA A AAA 191 O a T 191 A baa AE E a pA a pi 192 AUE AE E A T 192 AUEN EAA E E E 192 AE E E O E ETE 192 MO sonan iae a ida 192 QOS TE E vile Cie AE 193 LO 193 MU pia id S eee 193 O ta 193 O A A 193 MU oi 194 204 ri E E EET EEET 194 QO4B EE EET ET ET 194 A a EAE N cna tee tiene E a naleade ealeretea aa ete 194 A vate derivates ody are de detalii Lutein areas ia ayaeves 194 MU AA 194 UE 195 A erie vae E vege n cote uaa A 195 2049 ias 195 2050 iii A AA 195 QOS a INPC cetive evr ecvede ste ceve de cve ett decubecvetauvscevieaevieddvers 195 2052 iii AA ck tenes denver seen deeyes 195 ODS As 196 DOSS ii sicciia acs ssid ale ad E be wala E A dele vel ea dela uies 196 O IN 196 MUI ia 196 A o 196 AOT e OE A tereiheebeeaeres 197 MO ii A a pedii peeve debe pnie 197 2060 iii TEETE T EE EAT 197 2200 O 197 LO 197 2802
83. AE AEDE AE VAE aes ee eee 75 UDP Ala Mia A A As 75 A NE 75 E O 75 LO iii A A A 75 A ees iva taal an a aE 75 T8564 Gea Ancsatin dale cue ausaka cou oak aacknesanaas 76 TP Aliada 76 VB 689 daa As 76 A ves tte ca adlteruddehet toed neces dasae N 76 VB 692 Ala eve des 76 18720 AS Rath i ee eA eee ek 77 VB 720 A EN 77 187 22 vss scvsnianirx VEA EAKR deen vee NARNAIN ANNAT 77 18737 a lla 77 VO PSB es anda ices eae tas ce Shea stake A 77 AA A okie ie wee babienane ees 78 18740 norris peior E PEDEN i iUa eiS 78 A E EE ET 78 OT A A AA 78 LOTA io 78 A dieses ormseile aaa AAE E E 79 1874 en araar vinci gs viviaiciedwexseciseeeevbesaveess 79 VB 7 52 O eg 79 O 79 13 784 are AEAEE EE Nines eevee 79 MEMBER 80 LO it 80 E A eee Ts sek eee eae id sea wee eee Sask ashe 80 VET A E E 81 18832 dar dive eceedeenreee deve eae ceate peddle 81 A E 82 A RO 82 A NT TO 83 IGMP Al arity paete ani aaan bas cawe a a 83 18944 ie 83 ES A O A cRavi ese 84 ARPA lA a a 84 WOT A E 84 LITA T EEEE A EE 84 DOT Ana vad a A EE a 84 VO FVD RO 85 ON 85 19717 iii aa i viene Mia aout aise ee eee eee 85 L972 A Aiea ae AS Misa aoa Ae Seniesa 85 ISAS Ala rim e AEA da 86 19968 ii ns 86 A awed eadsneee E AEE TAE cove eae ee 86 1997 SS 86 VO TD ast Ee a a Se a a ER a a 87 TOOJA A O Lane Seren PL eat ihe 87 199 ii AA vena eat ees eee 87 199 7 Oishi iaeaea A ARA 87 Lcda 87 LI e Rath oo 88 A O 88 RENS Ke1 0 EEN AA aah eeeea eas EET 88 1998 AA 88 LIO LA o N d
84. ATION 205 ZXR10 Alarm Handling Manual Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH The suppression value must be more than the reuse value Please configure correct command 4015 4015 The maximum cycle of the suppression value must be over one half of the life cycle Please input the correct configuration parameter 4016 4016 0 as a mask is illegal Please input the correct command parameter 4030 4030 The BGP module is not existed Please check if the system is running correctly and the command configuration is proper 4031 4031 This neighbor does not exist Please check whether the command configuration parameter is correct 4032 4032 This neighbor already exists 206 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Chapter 3 Command Configuration Error Prompt Messages This is the system prompt 4033 4033 There is no aggregation policy Please set the aggregation p
85. Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages Please try again after deleting some useless configurations 9522 9522 Lacp can be configured for Ethernet interface type only Please check whether the command configuration is proper and correct 9523 9523 The interface does not support LACP Please check whether the command configuration is proper and correct 9601 9601 Error operation Please try again later 9602 9602 The IP address already exists in interface address group Please check whether the command parameter is correct 9603 9603 IP address conflicts with the one at other interface Confidential and Proprietary Information of ZTE CORPORATION 249 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message Number Alarm Reason Recommended Operations Message Number 250 ZTEDH Please check whether the command parameter is correct 9604 9604 Illegal IP address Please check whether the command parameter is correct 9605 9605 The ingress does not exist Please check whether the command configuration is correct 9606 9606 No group Please check whet
86. E CORPORATION 235 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No ZTEDH Please configure correct command 8625 8625 Please encapsulate VLAN ID at the interface first This is the system prompt 8626 8626 Fail to delete interface attribution Please try again later 8701 8701 Fail to create El interface Please check whether the command configuration is proper and try again later 8702 8702 This channelized group does not exist Please check whether the command configuration is correct 8703 8703 The time slot is used by another channel Please check whether the parameter configuration is correct 8704 8704 236 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages Too many channels are configured Please check whether the system configuration is proper 8705 8705 Please modify the frame encapsulation f
87. E E A dea seaausteennst 239 Mi O chev boi 239 MB PREE EAEE TEETER 239 A A A clea eld ulti astetiea 240 B91 Orrian eee helene E 240 A A 240 A ON 240 A E E da Oeeragmegarercihdedeenarengene tuen Sutera 240 esa 240 A O 241 O91 Baresi ie wen arenes 241 B91 irene Eiiceaet rep a ialeqrntw E a eel apen antares Ea 241 OD De es sack coh ve E sid swede seatu geet ys euk peen saan ates 242 to tie 242 O 242 OOF tae eave T edd ted viv deve edi Queene ddewtoncdvetntas 242 OOD D eie T ee vee ieleis ee Tevet eddie Saw eevee ele teak vtealre te 242 BISO A 243 QOOT ese a lala A Gveeaa ts 243 9002 eet O ee aS 243 A O 243 e 243 QOOS PPP irei aira aai a ooi aiva Ta r oiiae 243 MO Licor A OA eeeees 244 gTO2 er a tea ek acetate nahin ve a nena waie A 244 A aarti at ante eit te bled 244 O ere ae aes 244 91O Gropa instep ag nue A 244 O20 E tig vee cck eee eee tea vnateant sede E N shack eek ce wna tests 244 OZ OD as OO 245 9203 ici A a users 245 SPAO P AN 245 NO diu A a o 245 A eee E a ela hie vial eh se eee alah EO 245 QB OS siete die sete E aleahatealare te 246 A eae aes Aa 246 A vepldlaged aiseantw alanis eaten trios eens 246 BOG vid ieek ah eset eiseesk id 246 A A A puveianta ts O 246 O51 POE 247 QSL 1 uo EEEE 247 O ta vatealate de 247 QB TA esti A Mean e cite iain E 247 O 247 NI A a 247 A A A NO 248 A avant ee ten eae eal gaudy ge ves tau bast seeck eenk co anagey es 248 9519 ie ue devas cedvcted nev devee edd odie e civ dewmeredvectabas 248 O
88. EDH Current Power Module d is removed d power module number Alarm cleared Current Power work normal d the power serial number Multiple power states can be dis played simultaneously Example Alarm occured 15 20 31 06 26 2008 UTC alarm 74 occurred ENVIRONMENT Powerl do not work Alarm cleared 15 21 3 06 26 2008 UTC alarm 74 occurred ENVIRONMENT Powerl restart The power works abnormally ZXR10 3900 3200 5900 5200 UAS UAS10600 UAS10800E N A G series switch and ZX 15 75 5 Available Environmental Alarm 4 The fan works abnormally This leads to the abnormal working of the switch Check whether the power input and output of the fan is normal whether the fans are plugged correctly whether the fuse is OK Alarm occured Fan d do not work Alarm cleared Fan d restart d the power serial number Multiple power states can be dis played simultaneously UAS10800E Current Trunk s Fan fail to work s Top or Bottom Alarm cleared Current Cabinet Trunk Fan work normal s Top or Bottom Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Related Alarms Recommended Operations Alarm Prototype Description Chapter 2 Alarm Message Example Alarm occured 15 10 11 06 26 2008 UTC alarm 75
89. Equipment Alarm 5 During ZESS link state recovery the link is in PREUP state that is a transition from DOWN to UP N A Domain u from down to preup d the area id number it can be 1 4 An alarm 32513 level 5 occurred at 04 49 42 02 01 2001 UTC sent by NPC 2 ZESS Domain 1 from down to preup ZESS is in a preup state when the link state recovers ZXR10 T40 T64 T160 N A 32514 32514 6 Unavailable Equipment Alarm 5 The timer times out ZESS state turns from PREUP to UP N A Domain u from preup to up u area id it can be 1 4 An alarm 32514 level 5 occurred at 04 49 42 02 01 2001 UTC sent by NPC 2 ZESS Domain 1 from preup to up The timer times out ZESS state turns from PREUP to UP ZXR10 T40 T64 T160 Confidential and Proprietary Information of ZTE CORPORATION 131 ZXR10 Alarm Handling Manual ZTEHX Appendix Specification Message No Default Security Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype N A POE Alarm 30720 30720 6 None SoftProtocolAlarm 5 PSE disables POE function because of over temperature on the switch PSE recovers POE function because of temperature recov ers PSE total power of the power supply exceeds power threshold or recovers in the range of power threshold Cancel POE function due to high temperature PSE is made not to supply power because the total power of the power sup
90. Fahrenheit temperature of board the third d is the centigrade temperature of the set threshold and the fourth d is the Fahrenheit temperature of the set threshold An alarm 65 level 5 occurred at 01 58 40 01 28 2001 UTC sent by UPC MPU 2 ENVIRONMENT SFC Panel 1 Current local tem perature is 33 C 91F exceeds the second high threshold 32 C 89F An alarm 65 level 5 cleared at 01 58 50 01 28 2001 UTC sent by UPC MPU 2 ENVIRONMENT SFC Panel 1 Current local tem perature is 33 C 91F under the second high threshold 30 C 86F Board temperature is higher than the set second high temperature threshold T128 T64 T600 T1200 N A 66 66 5 Available Environmental Alarm 4 The CPU utilization exceeds the set memory utilization threshold The command used to set threshold for memory utilization is un der environmental configuration mode memory threshold Use the command show process to view the CPU utilization and analyzse whether it is normal or not Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Prototype Description Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Related Alarms Recommended Operations Alarm Prototype Description Chapter 2 Alarm Message Alarm Occurred s M panel d exceeds memory rate is 3 3f under the alarm threshold is d s S panel d
91. ID 1 3 6 1 2 1 105 1 3 1 1 4 pethMainPseUsageThreshold PSE power threshold OID 1 3 6 1 2 1 105 1 3 1 1 5 pethMainPowerUsageOffNotification PSE total power of the power supply recovers in the range of power threshold 1 PSE total power of the power supply exceeds power threshold or recovers in the range of power threshold 2 The configuration of SNMP related to PoE sending trap is cor rect N A pethMainPseGroupIndex PSE device number OID 1 3 6 1 2 1 105 1 3 1 1 1 pethMainPseConsumptionPowerPSE total power of power supply OID 1 3 6 1 2 1 105 1 3 1 1 4 pethMainPseUsageThresholdPSE power threshold OID 1 3 6 1 2 1 105 1 3 1 1 5 Confidential and Proprietary Information of ZTE CORPORATION 275
92. ION 157 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH None 212 212 End the file copy due to errors Check whether the line and system operation are normal If they are please try again later 213 213 Fail to transmit the response message Check whether the system running is normal if normal please try again later If error appeared many times please contact ZTE maintenance staff after recording the error 214 214 It does not support the system file reading and writing temporarily Informational notice No action is needed 215 215 It does not support the operation Please use the correct command Refer to the related user manual if possible 216 216 Incorrect file name 158 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Chapter 3 Command Configuration Error Prompt Messages Please configure correct command 217 217 No IP address has been designated Please inpu
93. Ipv6 interface description OID 1 3 6 1 2 1 55 1 5 1 2 ipv6IfOperStatus IPv6 interface operation status OID 1 3 6 1 2 1 55 1 5 1 10 IPv6 interface operation status type up 1 down 2 nolfIdentifier 3 unknown 4 notPresent 5 POE TRAP Information pethPsePortOnOffNotification The port PoE power supply status is changing 1 The port PoE power supply status is changing 2 The configuration of SNMP related to PoE sending trap is cor rect N A pethPsePortGroupIndexPSE device number OID 1 3 6 1 2 1 105 1 1 1 1 pethPsePortIndex Port index OID 1 3 6 1 2 1 105 1 1 1 2 pethPsePortDetectionStatus Port PoE power supply status OID 1 3 6 1 2 1 105 1 1 1 6 274 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message Description Trigger Conditions Recommended Operations Bound Variables Message Description Trigger Conditions Recommended Operations Bound Variables Chapter 4 TRAP Messages The port PoE power supply status type disabled 1 searching 2 deliveringPower 3 fault 4 test 5 otherFault 6 pethMainPowerUsageOnNotification PSE total power of the power supply exceeds power threshold 1 PSE total power of the power supply exceeds power threshold 2 The configuration of SNMP related to PoE sending trap is cor rect N A pethMainPseGroupIndex PSE device number OID 1 3 6 1 2 1 105 1 3 1 1 1 pethMainPseConsumptionPowerPSE total power of power supply O
94. M Alt Orca A ida 44 16899 ri id da 44 LIA OD 44 V6 9 A a oe ots 45 A aan iam ta caet ao Jane 46 16904 3 estudiar vad crane a 46 AA A O A eee 46 A aah Mesa eon ee Seas teste 46 A arate aE E eT a E cave Babee 46 A A 47 O ee E 47 A OA 47 1691 O 48 A A Ma eet EAEE OAN es 48 A ost Ais nce TAS Misa avon ae Seta ease 49 LIO Zi ii on bia as 49 16923 iii 49 A ened ead sees E iva deteey oo veea Bees ees 50 1692522 ii A ANS 50 II a 51 OSPF Alarm ower acannon A a 52 17408 vite ety A 52 17409 cts eaaa aa ota eee a a aN 52 LAAT O E A a adas oe 52 O E AEE E A O 53 WIAA ATE EE E E A A 53 WATS E AAEE E EE 53 VTA A AA 53 a O N TONO 53 17416 ii ada 54 VAT O 54 A A canind sg eitrsn ob n tk eyed abe eeea ate oat 54 VAL eee iis ences A eth eel Saeed ahs 54 WA ZO see A A data 55 n A E 55 y a EE A T 55 MU A E AT 56 TE PA EE EE 56 7427 Ses ten ceeds ON E E N U N ei 56 LULA Lt a A A A EOE 56 A A E R EN 56 RIP Alar dui sa 57 A Weel eek 57 Oi AA 57 A E ERRA ANE NOREEN eg 57 V7 6 7A sito AA N noe siasntc ANAT 57 LAG PA AA AS 58 LIO LAA AAA A A dadaxk tee 58 17673 A an 58 V7 67 Oi A EAEE 58 VIT a A A ia 59 BGP Alai da ci 59 A A A AA dag cue SaaSnts cou oak aanknesann ove 59 L792 A O tadetosiesadanseaiad ens 59 17922 Ada da 59 17923 A neces tans Scone itty esate 59 VA QQ RA vedas chav E ya hee A dee 60 VT ODD acacia etre Aa atti an ie Se an nage ie 60 VT ODT eae haste es AAA 60 1 928 EE E E EAE iaveea vacua dex veninve as Vesa vex 60 179
95. Manual Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No ZTEDH Fail to add ingress Please check if the parameter is correct and try again later 6029 6029 No RMON related information This is the system prompt 6030 6030 The statistics table is blank This is the system prompt 6031 6031 The history table is blank This is the system prompt 6032 6032 The history table is blank This is the system prompt 6033 6033 The host table is blank This is the system prompt 6034 6034 216 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Chapter 3 Command Configuration Error Prompt Messages The highest N host tables are blank This is the system prompt 6035 6035 The matrix table is blank This is the system prompt 6036 6036 The filter table is blank This is the system prompt 6037 6037 The capture table is blank This i
96. Message No Cause Recommended Operations Message No Cause Recommended Operations Message No ZTEDH 2008 2008 Fail to create OSPF area Please check whether the configuration reaches the maximum sys tem value and try again later 2009 2009 Fail to enable OSPF area It may try again later 2010 2010 Fail to create OSPF example Please check whether the system configuration reaches the maxi mum limitation and try again later 2011 2011 Fail to enable OSPF example It may try again later 2012 2012 This area is not NSSA area Please check if the input parameter and the command configura tion are correct 2013 2013 188 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Chapter 3 Command Configuration Error Prompt Messages Fail to delete the area default information Please check if the command configuration is proper and try again later 2014 2014 Fail to set the area default information Please check if the command configuration is proper and try again later 2015 2015 Fail to delete NSSA area Please check if the command configuration sequence is prope
97. N coins Veceees 249 A O ON 249 O UNO Wie vue e 249 A A A A O ss 249 A cea E pede eebev ane es eens Hele bv yds na chev aged eek er ees es eebyes 249 SLO EEE sdovie TE diester ever renee ceeds 250 960S A A 250 A tae ae ens con aaa aon tm aah E rane 250 MA A A eedpees 250 A ve dicen pinhead arene as 250 LE E E fee sudelteuerss 250 US A o 251 LIADO ic ever devise ub eWeedeecvvr devise eees 251 T2405 ini ii A 251 TILA 251 VIA A A evant ay 251 T2409 ieii ieee KAE avec nie ei arias eie eects 252 A n pice ead a eee we punle vate tatu 252 E Vivaah Geaie cnc ccdie cake vik as taaoueGn E 252 T2420 ANN 252 T2421 cvcicevec eer vevceevevecee ces veedadeevavncvr TET 252 12422 inicia A a 252 12423 iii io 253 A A E E 253 T2425 A A 253 124 26 O O 253 LU A das 253 A ise dine eiayeise O Westen wie rues 253 aE AS P AE dais rains tirireredeibenaieag dea seauster ss 254 T2430 A po es 254 1243 iian ettaro antait ene aasaran ra naair in 254 A A E E A Sate a atid 254 TA 254 TOO 254 UML ai 255 A OT 255 MUDA dedda se aa estaba E T 255 J020 Beriini arrora enced ada 255 OL iii A ra AA 256 TRAP Messages o ccococonoocoonnnononnnnnoonnnnnnnnnnnnnnnnn 29 TRAP Message ExplanatiON ooocccccccccncncnnconnncnnnnnnncnnannanos 257 System TRAP MESSAGE ui a anew deiate te eeie cele ee 257 CO ad a 257 War Static A A A 258 aUthenticationFailUre ccccceceeeeeee esse eee eeeeeaeeaeeeeeaes 258 TR A O A saga se 258 HINKDOWM ieee E A sete 259 Alarm PRAP Message
98. No Cause Recommended Operations Message No Cause ZTEDH cluster id number cannot be 0 Please input correct command parameter and perform correct command configuration 4501 4501 No ISIS example is running Please check whether the configuration is correct 4502 4502 The area address quantity reaches the maximum value This is the system prompt 4503 4503 No priority can be set in ppp connection Please check whether the command configuration is correct 4504 4504 No DIS parameter can be set at a non broadcast interface This is the system prompt 4505 4505 No retransmission interval can be set at a broadcast interface 210 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages Please check whether the command configuration is correct 4506 4506 The no router isis command is executed Please try again later Try again later 4507 4507 The isis route is being deleted since the level varies Please try again later Try again later 4508 4508 system id exceeds the permitted range Please check whether the input parameter is correct and proper 4509
99. ON 121 ZXR10 Alarm Handling Manual Cause Alarm ProtoType Description Message No Default Severity Level Cause Alarm ProtoType Description Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Prototype Description ZTEDH In case alarm state is Occurred it indicates that an alarm has occurred and generally the reason is TCP SYN Waittime changes Alarm occurred 00 00 12 01 01 2001 UTC alarm 29954 occurred MIX TCP SYNWAIT time is changed for defending syn flood attacking sent by MCP 29955 29955 6 In case alarm state is Occurred it indicates that an alarm has occurred and generally the reason is TCP SYN Waittime restores to the original value Alarm occurred 00 00 11 01 01 2001 UTC alarm 29955 occurred MIX TCP SYNWAIT time is recovered sent by MCP 29956 29956 5 Available QoSAlarm 4 Alarm occurred The received packet in per unit time is more than the set value The command used to set the value is ZXR10 config if port up send limit packets num receive interval num close interval num The mode is interfasce configure mode the received packet is counted by number and the time unit is seconds By default to receive 20 packets costing 2 seconds Alarm cleared Recover automatically when the set closing time is over The con figure mode and the value is the same as the above The time unit is minute
100. P packet is unidentifiable Check whether the system configuration is correct 18752 18752 5 Fail in IP splicing operation If a large amount of such alarms occur continuously please check whether the system running is normal 18754 18754 5 IP packets regrouping is overtime Check whether the network running status is normal 18784 18784 4 route map is configured on xx digital No line card and there is no way to be valid Confidential and Proprietary Information of ZTE CORPORATION 79 ZXR10 Alarm Handling Manual Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No ZTEDH Please check whether the enabled route map configuration on the line card is reaching to system permitted limit configuration if no contact ZTE maintenance staff in time after recording the informa tion 18785 18785 4 route map configuration has no way to be valid Please check whether the enabled route map configuration is reaching to system permitted limit configuration if not contact ZTE maintenance staff in time after recording the information 18786 18786 4 Policy route has been configured with too many sequence item whic
101. PF virtual neighbor OID 1 3 6 1 2 1 14 9 1 2 ospfVirtIfState OSPF virtual interface status OID 1 3 6 1 2 1 14 9 1 7 ospfNbrStateChange OSPF non virtual neighbor status change 262 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Triggering Criteria Recommended Operations Binding variables Information Description Triggering Criteria Recommended Operations Binding variables Chapter 4 TRAP Messages 1 OSPF non virtual neighbor status change may be to normal direction or may be the status regress caused by abnormal cases 2 The configuration for SNMP related OSPF sending trap is cor rect Please check whether OSPF neighbor status change is normal if not check whether the router system is running normally and whether the link connection is normal ospfRouterld router ID used to distinguish the routers in au tonomous system and the value is only value OID 1 3 6 1 2 1 14 1 1 ospfNbrIpAddr OSPF neighbor interface IP address which might be another interface address in connection without address OID 1 3 6 1 2 1 14 10 1 1 ospfNbrAddressLessIndex the IP address index on interface mib table which corresponding to OSPF neighbor interface OID 1 3 6 1 2 1 14 10 1 2 ospfNbrRtrid the router ID of OSPF neighbor router OID 1 3 6 1 2 1 14 10 1 3 ospfNbrState OSPF neighbor status OID 1 3 6 1 2 1 14 10 1 6 ospfVirtNbrStateChange OSPF virtual neighbor status
102. RMEPCCMdefect defect disappear when alarm disappears the alarm is the content which shows above Example 1 10 38 07 08 10 2009 UTC alarm 30465 occurred CFM SomeRMEPCCMdefect MD 1 MA 1 MEP 2 has not received CCM Confidential and Proprietary Information of ZTE CORPORATION 35 ZXR10 Alarm Handling Manual ZTEHX Alarm Description Supported Devices Appendix Specification Message No Default Security Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype from some remote MEPs expired 3 5 times CCM s transmission interval 2 10 38 10 08 10 2009 UTC alarm 30465 occurred CFM MD 1 MA 1 MEP 2 SomeRMEPCCMdefect defect disappear When configured local MEP can t receive CC message sended from peer this alarm will appaer All series This alarm can be available from V4 8 23 30466 30466 6 Available ConfigureErrorAlarm 5 The local or peer configuration has error Local receives faulty CC message Local prints alarm View local and remote configurations s MD d MA d MEP d s The first od is the ID of MD with RDI alarm The second d is the ID of MA with RDI alarm The third d is the ID of MEP with ERR alarm The first s is errorCCMdefect when alarm appears the alarm is the content which shows above When alarm disappears this character string is empty The second character string content is one or more inval
103. SPF example for ROUTE ID If possible perform state machine change again or set the relevant parameters again Confidential and Proprietary Information of ZTE CORPORATION 67 ZXR10 Alarm Handling Manual Message No Default Severity Level Cause Recommended Operation Message No Default Severity Level Cause Recommended Operation Message No Default Severity Level Cause Recommended Operation Message No Default Severity Level Cause Recommended Operation Message No Default Severity Level Cause Recommended Operation ZTEDH 18184 18184 6 OSPF is not started but it receives report Check whether the relevant router configuration is correct 18185 18185 6 No IFB matches the received OSPF report Check whether the relevant router configuration is correct 18186 18186 6 IFB DOWN OSPF report discarded Check whether the relevant router configuration is correct and the interface status is normal 18189 18189 6 Errors occur in IP synchronization route table Check whether the router and interface is running well and the configuration is correct 18190 18190 6 Fail to distribute memory Check whehter the router running is normal the configuration is proper and the system memory application is to maximum system operation limits 68 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Default Severity Level
104. Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Related Alarms Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Related Alarms ZTEDH N A 310 310 6 Unavailable Equipment Alarm 5 The hardware is instable Fails to write to the register in interface board initialization or the platform command configuration The interface board or the line card can not work normally The platform command configuration fails No Plug the interface board or the line card again If the malfunction still exists then contact ZTE customer service personnel to check whether the interface board or the line card is abnormal write register failed baseaddr 0x 08x offset 0x 4x 08x the base address 04x the offset address Example 14 17 56 05 20 2008 UTC alarm 303 occurred Board write register failed baseaddr 0xC6002000 offset 0x0006 sent by NPC 2 Alarm appears when the line card fails to modify the register Alarm may also appear when failing to write to the register in interface board initialization or the platform command configura tion It is used to diagnose the hardware abnormity T64E T128 T600 T1200 N A 311 311 5 Unavailable Equipment Alarm 5 The board link for
105. The address is used at interface Please check whether the system configuration is proper 8516 8516 The subscriber is online This is the system prompt 8517 8517 Please check the encryption type Please check whether the command configuration is correct 8601 8601 Fail to add address pool Please try again later 8602 8602 Fail to delete address pool Confidential and Proprietary Information of ZTE CORPORATION 231 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH Please try again later 8603 8603 Fail to add rules Please check whether the command configuration is correct and reaches the maximum system permitted value and then try again later 8604 8604 Fail to delete rules Please try again later 8605 8605 Fail in interface configuration Please try again later 8606 8606 Fail in interface configuration Please try again later 8607 8607 NAT board is not got ready 232 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause
106. The relevant configuration for SNMP sending trap is correct Please check whether the system is running normally and the in terface connection cable is well ifIndex interface index OID 1 3 6 1 2 1 2 2 1 1 ifAdminStatus interface managing status OID 1 3 6 1 2 1 2 2 1 7 ifOperStatus interface operating status OID 1 3 6 1 2 1 2 2 1 8 Alarm TRAP Message Hardware Alarm Trap The trap is sent when a hardware alarm occurs on equipment 1 A hardware related alarm occurs on equipment 2 The equipment is configured the unm on and unm server com mands 3 The relevant configuration for SNMP sending trap is correct Please find the corresponding operation recommendation accord ing to the alarm code bound in alarm trap Rack No value 1 OID 1 3 6 1 4 1 3902 3 4 6 1 1 Shelf No value 1 OID 1 3 6 1 4 1 3902 3 4 6 1 2 Slot number OID 1 3 6 1 4 1 3902 3 4 6 1 3 Port No value O if no corresponding port existed OID 1 3 6 1 4 1 3902 3 4 6 1 4 Alarm Code OID 1 3 6 1 4 1 3902 3 4 6 1 5 Alarm Severe level Confidential and Proprietary Information of ZTE CORPORATION 259 ZXR10 Alarm Handling Manual ZTEHX Information Description Triggering Criteria Recommended Operations Binding variables OID 1 3 6 1 4 1 3902 3 4 6 1 6 Alarm generation time OID 1 3 6 1 4 1 3902 3 4 6 1 7 Alarm status alarm created alarm cleared OID 1 3 6 1 4 1 3902 3 4 6 1 8 Alarm type environment alarm 1 line card alar
107. U 1 Telnet execute write terminal 10 56 20 06 27 2007 UTC alarm 16917 occurred 0AM Writing configuration aborted because vty 0 is closed sent by UPC MPU 1 The terminal number after vty keeps consistent with the one after command who 16918 16918 Confidential and Proprietary Information of ZTE CORPORATION 47 48 Default Severity Level Cause Recommended Operations Alarm Prototype Description Appendix Specification Message No Default Severity Level Cause Alarm Prototype Description Appendix Specification Message No ZXR10 Alarm Handling Manual ZTEHX If one of the terminal execute write operation then the terminal is in the phase of background file copy because it already finishes the configure collection if the connection is cut then alarm is gen erated The possibility of disconnection is as follows Cut down the windows of the terminal directly Console telnet connection times out Other terminal executes clear tcp to delete a TCP link Do not cut this connection as much as possible when write op eration is being performed If connection is cut down when write is still executing file operation then write continues in the back ground as far as the final startrun created Please do not restart the bracket Alarm occurred The serial port interrupts to execute write 10 59 29 06 27 2007 UTC alarm 16918 occurred OAM Con O is closed but writin
108. ZTE CORPORATION ZTEDH Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Chapter 2 Alarm Message The neighbor receives the update but NLRI exceeds the maximum prefix length Please check whether the BGP protocol module configuration is correct and proper 17946 17946 6 Invalid routes are received Check whether the route design of transmitting end is correct and proper because it might be loopback route 17947 17947 6 The neighbor receives update report of which MR_REACH_NLRI is the VPN IPV4 address cluster but the RD domain is not 0 and BGP will ignore the domain Please check whether the BGP protocol configuration is correct and network operation is normal 17949 17949 6 Incorrect NOTIFICATION report Check the TX end settings 17950 17950 7 Fail to transmit report Check whether the port is operating normally 17951 17951 Confidential and Proprietary Information of ZTE CORPORATION 63 ZXR10 Alarm Handling Manual Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity L
109. ZTEDR ZTE CORPORATION ZTE Plaza Keji Road South Hi Tech Industrial Park Nanshan District Shenzhen Tel 86 755 26771900 Fax 86 755 26770801 URL http ensupport zte com cn E mail support zte com cn ZXR10 Router Ethernet Switch Alarm Handling Manual Version 4 8 23 LEGAL INFORMATION Copyright 2006 ZTE CORPORATION The contents of this document are protected by copyright laws and international treaties Any reproduction or distribution of this document or any portion of this document in any form by any means without the prior written consent of ZTE CORPO RATION is prohibited Additionally the contents of this document are protected by contractual confidentiality obligations All company brand and product names are trade or service marks or registered trade or service marks of ZTE CORPORATION or of their respective owners This document is provided as is and all express implied or statutory warranties representations or conditions are dis claimed including without limitation any implied warranty of merchantability fitness for a particular purpose title or non in fringement ZTE CORPORATION and its licensors shall not be liable for damages resulting from the use of or reliance on the information contained herein ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the subject matter of this document Except as expressly provided in any w
110. ZXR10 Alarm Handling Manual Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype ZTEDH 9 42 31 08 26 2008 UTC alarm 33294 occurred EPON Epon alarm optical protection switch from interface epon olt_3 13 to interface epon olt_3 14 sent by NPC 3 Optical protection switch occurs on EPON EPON project of 4822 33295 33295 5 QOSAlarm 5 ONU remote configuration timeouts The previous configuration of this ONU is invalid Please check if the connection between OLT device and ONU device is normal ONU s remote configuration timeouts SOLT sub interface name Example 00 49 44 12 14 2008 UTC alarm 33295 occurred EPON ONU epon olt_2 16 2 remote configuration timeouts sent by MEC 1 ONU remote configuration timeouts ZXR10 8900 33296 33296 6 ProcessingErrorAlarm 5 ONU remote configuration fails for invalid parameter ONU remote configuration command is invalid Check if remote configuration ONU command is correct ONU s remote configuration fails for invalid parameter SOLT sub interface name Example 00 54 34 12 14 2008 UTC alarm 33296 occurred EPON ONU epon olt_2 16 2 remote configuration fails for in
111. ad is d The first s is CPU type The first d is panel number and the second d is CPU utilization CPU load namely CPU utilization ratio exceeds the set high thresh old All The platform 4 6 03b and the upgrade versions support this alarm Not CE amp PTN version Confidential and Proprietary Information of ZTE CORPORATION 45 ZXR10 Alarm Handling Manual Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause ZTEDH 16903 16903 5 FLASH tests are not successful Check the hardware of the equipment and check whether FLASH exists or there is something abnormal 16904 16904 5 FLASH exists but can not work normally after setting up the rack Change FLASH for a new one or set up the rack without FLASH 16905 16905 4 Backplane fails to write nvram Backup the configuration to prevent configuration loss Check whether the backplane is running normally Change the backplane if neccesarry 16906 16906 6 Distributing system RP sends a message to MP and inform to add or delete interface Give an alarm after the synchronized message fails Send the alarm message to ZTE s maintenance personnel 16907
112. ain later 7004 7004 Error asynchronization message Please try again later 7005 7005 No data in synchronous message Please try again later 7006 7006 Error message data header This is the system prompt Please try again later 7007 7007 Error process status Please check whether the system is running normally 7008 7008 Fail in initialization 222 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages Please check whether the system is running normally 7010 7010 Memory application failure Please check whether the system is running normally 7011 7011 Memory release failure Please try again later 7012 7012 Error internal communication status Please try again later 7020 7020 Fail to write to database Please try again later 7021 7021 Fail to access database Please try again later 7022 7022 Fail to delete database Confidential and Proprietary Information of ZTE CORPORATION 223 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations M
113. al and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages Please check whether the command configuration is correct 8903 8903 The address already exists in the map Please check whether the input parameter is correct and proper 8904 8904 The system has no available memory Please try again after removing some useless configurations 8905 8905 No address map can be found for the IP Check whether the related configuration is correct 8906 8906 No frame relay is configured Please check whether the system configuration is correct 8907 8907 Error frame relay parameter Please check whether the input parameter is correct 8908 8908 To configure DCE NNI must enable frame relay exchange Confidential and Proprietary Information of ZTE CORPORATION 239 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No
114. alarm 29698 occurred all neighbours clear on fei_1 2 sent by MCP All the neighbourhood is removed No UDLD HELLO packet is from the other end ZXR10 3900 6900 29699 29699 3 Available CommunicationAlarm 3 1 When the interface is under Aggressive mode all the neighbor is aging 2 Optical interface The sending and receiving optical fibres con nect two different interfaces Sets the interface state to err disable No protocol is running un der this interface Check immediately whether the link connection between this port and the other port is normal interface unidirection occurs on s s interface name 00 28 48 01 01 2001 UTC alarm 29699 occurred interface unidi rection occurs on fei_1 2 sent by MCP 00 03 17 01 01 2001 UTC alarm 29699 cleared UDLD inter face unidirection clears on fei_1 2 sent by MCP Confidential and Proprietary Information of ZTE CORPORATION 129 ZXR10 Alarm Handling Manual Alarm Description Supported Device Message No Default Severity Level Cause Recommended Operation Alarm Prototype Description Alarm Description Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Recommended Operations Alarm Prototype Description ZTEDH Monologue occurs in the port ZXR10 3900 6900 MUX Alarm 29440 29440 6 Please add protocol packet test function on high end switch Give alarms to remind users for the abnormal protoc
115. ame is the same as an existed directory Please input the correct command parameter 250 250 The rule expression is too long Please input the correct command parameter 251 251 Fail to distribute the memory for rule expression 164 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages Please input the correct command parameter and try again later 252 252 There are too many symbols in the rule expression Please input the correct command parameter 253 253 The in the rule expression does not pair Please input the correct command parameter 204 254 The in the rule expression is mismatched Please input the correct command parameter 259 255 Internal error occurs during rule expression generation Please check whether the input command is proper and try again later 256 256 The and operations in the rule expression cannot be vacant initially Confidential and Proprietary Information of ZTE CORPORATION 165 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations M
116. are applicable to the autonomous domain division ospfRouterld router ID used to distinguish the routers in au tonomous system and the value is only value OID 1 3 6 1 2 1 14 1 1 ospfExtLsdbLimit the maximum non default external LSA quantity able to store on link status database OID 1 3 6 1 2 1 14 1 11 ospfLsdbApproachingOverflow LSA quantity on link status database exceeds 90 of maximum external link status database value 1 LSA quantity on link status database exceeds 90 of maximum external link status database value 2 The SNMP configuration about OSPF trap sending is correct Please check whether the autonomous domain system operation is normal the router configuration is proper and the permitted router performance parameters is applicable to the autonomous domain division ospfRouterld router ID used to distinguish the routers in au tonomous system and the value is only value OID 1 3 6 1 2 1 14 1 1 ospfExtLsdbLimit the maximum non default external LSA quantity able to store on link status database OID 1 3 6 1 2 1 14 1 11 270 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Information Description Triggering Criteria Recommended Operations Binding variables Information Description Triggering Criteria Recommended Operations Binding variables Information Description Chapter 4 TRAP Messages ospflfStateChange OSPF non virtual interface status
117. ary Information of ZTE CORPORATION ZTEDH Cause Recommended Operations Message No NM Level Cause Recommended Operations Message No NM Level Cause Recommended Operations Message No NM Level Cause Recommended Operations Message No NM Level Cause Recommended Operations Message No NM Level Cause Recommended Operations Chapter 2 Alarm Message The message return area received by RMON module is wrong Check whether the system running status is normal 20757 20757 6 The command ID received by RMON module is wrong Check whether the command configuration is correct and the sys tem running is normal 20758 20758 6 The command parameter received by RMON module is wrong Check whether the command configuration parameter is correct 20759 20759 6 The command parameter quantity received by RMON module is wrong Check whether the command configuration parameter is correct 20776 20776 6 The RMON timer is wrong Check whether the system running status is normal and being able to perform the relevant RMON configurations again 20793 20793 6 The resources do not exist Check whether RMON configuration command is correct and the relevant system parts are normally running Confidential and Proprietary Information of ZTE CORPORATION 91 ZXR10 Alarm Handling Manual Message No NM Level Cause Recommended Operations Message No NM Level Cause Reco
118. as aa 147 A deueeeeaes 147 VS id vaca A A E ecu ee ele os 148 LA A E cies denen adds 148 A O 148 A e ates 148 VA A A beset eis 148 MR aa 149 NO E S A PAN 149 O A a AAE ANANE 149 ra E dt 149 a e 149 DIN ad 150 DA SI AAA AS 150 A Cee TEAN ANA PNE NEA EENAA ENAN A 150 O A T AA 150 DI AE A AO A O T 150 A A dian AOE EEEN 151 QO E E 151 O ater ve NA OLAANN SAES EEEa T EAEAN a 151 BA O OO E E E E 151 ee EE E E E E E Ore re Sarees 151 BA E A N E A AE A dala dat eis 151 A no 152 TR ENA 152 A A uae user LT geste 152 A A O 152 O 152 MO ada 153 WA A AS 153 A AN ae Rath neath eC A ek a 153 ta 153 VI ia 154 A O A E eae s 154 O o E 154 A dened ceiltectovidensavievelete ener eeneiee dds 154 UD 155 MU A a 155 O sve seaG ee tang ck subbae ers aoe desea cae seek eeeasaae eee 155 A tase Ace preetampaes O O 155 VLG s pedens vn dedeete pede A o eb 155 LL iia RA A 155 MUA A A 156 DIA A eer aA 156 203 wile a a A 156 2OF stented einai yi Aaa 156 P cad O 156 DOT sea Mes anaes ta oo 157 208 init A A A A 157 209 ri ni A AO E yet 157 LA 157 DAA a iat taht ah ats at ade da tah fey 157 2d 2 ai tied veneer OO 158 a a a 158 ZA O O 158 21D cider O 158 21G ri A O yee 158 217 ii A a AAA 159 218 ri A EET 159 DA ee renee eer rere 159 DA A dca elves 159 O O 159 A OE 160 A dd 160 DOA di A OO 160 225 iii A A A pe eets 160 226 ii it A A RR 160 LA AA 160 LA eden oe wa cee lire tte ia A 161 229 apit pestames Ok dem tnc plead taconite penne pee a
119. ase configure main RADIUS server first 2001 2001 No IP example is running None 2002 2002 OSPF example is already running 186 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Chapter 3 Command Configuration Error Prompt Messages Informational notice No action is needed 2003 2003 It is not an NBMA interface Please check whether the parameter configuration is correct and proper 2004 2004 No OSPF example is running Please check whether the command configuration sequence is proper and the configuration is correct 2005 2005 The OSPF area does not exist Please check whether the input parameter is correct 2006 2006 The area is disabled Please check whether the command configuration is proper and the parameter is correct 2007 2007 The area is disabled Please check whether the command configuration is proper and whether the parameter is correct Confidential and Proprietary Information of ZTE CORPORATION 187 ZXR10 Alarm Handling Manual Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations
120. at to reboot the device when it is still running No Alarm occurred 11 22 27 05 29 2007 UTC alarm 16389 occurred ROS SNMP agent on host ZTE is undergoing a cold start sent by MCP 16391 16391 5 Unavailable CLASS_NOTIFY 4 38 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Cause Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Type NM Level Cause Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Chapter 2 Alarm Message The current version is in trial run state The command updatever activate in privilege mode can be used to remove the try running alarm Current version is in try running and activate it please Example 14 28 01 03 21 2008 UTC alarm 16392 occurred ROS Current version is in try running and please activate it sent by MEC 1 The current version is in trial running state and it need to be acti vated by users Or the device reboots automatically after a while The remaining time can be viewd by command show updatever in privileged mode CE amp PTN 6100 CE amp PTN 8900 CE amp PTN version supports this alarm 16392 16392 5 CLASS_NOTIFY 4 The current version is the rollback The reason ma
121. ation Cause Ethernet oam protocol status to change Confidential and Proprietary Information of ZTE CORPORATION 31 ZXR10 Alarm Handling Manual ZTEHX Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype Check attribute configuration and re initiate Ethernet OAM proto col negotiation Discovery s localmac s peermac s The first s details are as follows 1 Reset for remote unsatisfied The remote can t satisfy the modified configuration 2 Reset for local unsatisfied The local can t satisfy the modified configuration 3 is successfully connected Discovery is successfully connected The second s and the third s source MAC address and desti nation MAC address Examples 00 16 14 01 01 2001 UTC alarm 16130 occurred ETHOAM Discovery Reset for remote unsatisfied localmac 00d0 d0c6 5e27 peermac 00d0 d0c0 7d81 on fei_1 1 sent by NPC 1 00 16 14 01 01 2001 UTC alarm 16130 occurred ETHOAM Discovery Reset for local unsatisfied localmac 00d0 d0c6 5e27 peermac 00d0 d0c0 7d81 on fei_1 1 sent by NPC 1 00 16 14 01 01 2001 UTC alarm 16130 occurred ETHOAM Discovery is successfully connected localmac 00d0 d0c6 5e27 peermac 00d0 d0c0 7d81 on fei_1 1 sent by NPC 1 The local and remote can t satisfy the Ethernet oam protocol at tribute co
122. ation Description Triggering Criteria Recommended Operations Binding variables Chapter 4 TRAP Messages ospfVirtIfNeighbor the router ID of OSPF virtual neighbor OID 1 3 6 1 2 1 14 9 1 2 ospfConfigErrorType the possible types of OSPF configuration er rors as error version number mismatched area number and un known virtual neighbor OID 1 3 6 1 2 1 14 16 1 2 ospfPacketType OSPF packet type hello packet IsReq packet and IsAck packet OID 1 3 6 1 2 1 14 16 1 3 ospflfAuthFailure The authentication type or key of OSPF report received at non virtual interface is inconsistent with the relevant configuration of the router which causes the authentication failure 1 The authentication type or key of OSPF report received at non virtual interface is inconsistent with the relevant configuration of the router 2 The SNMP configuration about OSPF trap sending is correct Please check whether the router configuration is consistent with the one about OSPF at the opposite end router ospfRouterld router ID used to distinguish the routers in au tonomous system and the value is only value OID 1 3 6 1 2 1 14 1 1 ospflfIpAddress the IP address at OSPF interface OID 1 3 6 1 2 1 14 7 1 1 ospfAddressLesslf index of interface without address O for inter face with address and ifIndex index for interface without address OID 1 3 6 1 2 1 14 7 1 2 ospfPacketSrc OSPF report IP address unable to be ident
123. ause Recommended Operations Chapter 3 Command Configuration Error Prompt Messages 8956 8956 No member interface Please check whether the command configuration is correct 9001 9001 The interface is not existed Please check whether the input command parameter is correct 9002 9002 No address is configured on this interface Please check whether the command configuration is proper 9003 9003 Operation failure Please try again later 9004 9004 The acl table ID does not exist Please check whether the command parameter is correct 9005 9005 The group broadcast routing table does not exist Please check whether the system is running correctly and the con figuration is correct Confidential and Proprietary Information of ZTE CORPORATION 243 ZXR10 Alarm Handling Manual Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH 9101 9101 The pimdm is started on this interface This is the system prompt 9102 9102 The pimdm is not started on this interface None 9103 9103 The pimdm has no matched group broadcast routing table ingress Please check whether the system command configuration is cor rect and proper 9105 9105 The interface is d
124. board T64E T128 16395 16395 5 Available EquipmentAlarm 4 SD is removed SD removed notice Insert SD Alarm Occured SD is removed Slave SD is removedslave board Alarm Recovery SD is inserted Slave SD is insertedslave board Examples Alarm Occured 18 30 50 09 02 2008 alarm 16395 occurred ROS SD is re moved sent by MEC 1 18 32 55 09 02 2008 alarm 16395 occurred ROS Slave SD is removed sent by MEC2 Alarm Recovery 18 30 51 09 02 2008 alarm 16395 cleared ROS SD is inserted sent by MEC 1 18 33 00 09 02 2008 alarm 16395 cleared ROS Slave SD is inserted sent by MEC2 SD is removed 89 and 69 series routing switch This alarm can be available from V4 8 22 16396 16396 4 ProcessingErrorAlarm Confidential and Proprietary Information of ZTE CORPORATION 41 ZXR10 Alarm Handling Manual NM Level Cause Influence Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations ZTEDH 5 When slice memory is applied if the first valid slice memory in slice idle table the physical next block or the logical next block has check failure the applied slice memory is modified illegally Maybe memory is exhausted Use the show processor command to view if memory utilization Memory is abnormal Slice
125. bor fails to delete from GROUP Please try to delete again 17964 17964 7 Fails to transmit refresh packet Please check whether the physical link is normal DRP Alarm 18176 18176 6 Fail to create IPI example If possible perform state machine change again 18177 18177 66 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Default Severity Level Cause Recommended Operation Message No Default Severity Level Cause Recommended Operation Message No Default Severity Level Cause Recommended Operation Message No Default Severity Level Cause Recommended Operation Message No Default Severity Level Cause Recommended Operation Chapter 2 Alarm Message 6 Fail to create BGP example If possible perform state machine change again or set the relevant parameters again 18180 18180 6 Fail to enable IPI example If possible perform state machine change again 18181 18181 6 During AS No setting fail to enable IPI example again If possible perform state machine change again or set the relevant parameters again 18182 18182 6 Fail to enable IPI example with a timer If possible perform state machine change again or set the relevant parameters again 18183 18183 6 The IPI example fails exact information is in the generated alarm message description which differs as the configuration varies to create O
126. called remote stable alarm in EPON project In de fault this alarm is enabled If the alarm need to be disabled con figure alarm remote stable disable on OLT interface This alarm generates on ONU side and be sent back to OLT Confidential and Proprietary Information of ZTE CORPORATION 137 ZXR10 Alarm Handling Manual Alarm Description Prototype Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level Cause Influence Recommended Operations ZTEDH Epon alarm remote stable occour Example 15 52 30 08 26 2008 UTC alarm 33284 occurred EPON Epon alarm remote stable occour sent by NPC 3 Detect on remote OLT system mixes ONU version EPON project of 4822 33285 33285 5 CommunicationAlarm 5 When ONU shouldn t change encryption key encryption key is the key that generates randomly in ONU discovery process and used to encrypt and decrypt the data forwarded from ONU to OLT it changes Optical path is abnormal Disconect re connect and register ONU This alarm is called bad encryption key alarm in EPON project In default this alarm is enabled If the alarm need to be disabled configure alarm bad encryption key disable on OLT interface Epon alarm bad encryption key
127. can not be solved Discard the packets and take corresponding actions 311 Check whether the board link forwarding is normal or not Whether there is packet loss or not The device reboots the relative hard ware automatically NP d forward link has exception warning d board number 15 27 36 08 09 2008 UTC alarm 313 occurred Board NP 6 forward link has exception warning sent by NPC 6 The forwarding link is abnormal T64E T128 T600 T1200 28 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Appendix Specification Message No Default Severity Level Cause Recommended Operations Alarm Prototype Description Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Chapter 2 Alarm Message N A Port Alarm 512 512 6 The port is down or up If it is a port down message please check whether the port con nection is normal Alarm occurs 10 12 57 09 15 2003 UTC alarm 512 occurred Down on fei_5 6 sent by SMP 1 Alarm clears 10 12 59 09 15 2003 UTC alarm 512 cleared PORT Port Up on fei_5 6 sent by SMP 1 PORT Port 540 540 6 The aggregation of port configuration in SMARTGROUP interface is successful No 541 541 6 The aggregation of port configuration in SMARTGROUP interface fails No 542 542 6 Conf
128. cast type router link network link and group broadcast link OID 1 3 6 1 2 1 14 4 1 2 ospfLsdbLsid link status ID formed by router ID or IP address OID 1 3 6 1 2 1 14 4 1 3 ospfLsdbRouterld router ID originating link status broadcast re port OID 1 3 6 1 2 1 14 4 1 4 268 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Information Description Triggering Criteria Recommended Operations Binding variables Information Description Triggering Criteria Recommended Operations Binding variables Chapter 4 TRAP Messages ospfOriginateLsa The router creates a new link status broadcast report 1 The router creates a link status broadcast report because of the topology change of the autonomous domain where the router is in 2 The SNMP configuration about OSPF trap sending is correct Please check whether the topology status change in autonomous domain is normal ospfRouterld router ID used to distinguish the routers in au tonomous system and the value is only value OID 1 3 6 1 2 1 14 1 1 ospfLsdbAreald the area ID of router value 0 0 0 0 for outside of autonomous system OID 1 3 6 1 2 1 14 4 1 1 ospfLsdbType link status broadcast type router link network link and group broadcast link OID 1 3 6 1 2 1 14 4 1 2 ospfLsdbLsid link status ID formed by router ID or IP address OID 1 3 6 1 2 1 14 4 1 3 ospfLsdbRouterld router ID originating link status broa
129. ch appears in the system run ning and the handling of traffic process Real time display or stor age into the database is executed in form of alarm or notice on the user oriented alarm monitoring platform It also provided the in terface direct viewing monitoring or the historical inquiry method to reflect the current or the past system running status and the handling of traffic process All of these helped the maintenance personnel to do the troubleshooting and take preventive mea sures so that the system and the service restores normal as soon as possible Alarm Glossry Overview Message No Message No is also named alarm code It is the unique identi fication to distinguish alarms It includes foreground alarm and backgroud alarm The foreground alarm code is a fixed value de fined by macro for distinguishing alarms Because alarm and the corresponding recovery use the same alarm code only alarm code and notice code need to be defined The alarm source provides the macro name in the alarm code identifier macro column The back ground alarm code is used to display in alarm monitoring platform and is mapping with the foreground alarm code one by one ac cording to some rules Confidential and Proprietary Information of ZTE CORPORATION 1 ZXR10 Alarm Handling Manual ZTEHX Default Severity Level ZXR10 devices alarm level includes the following 8 levels Severity 1 emergency messages EMERGENCIES the system is unusable
130. change 1 OSPF non virtual interface status change 2 The SNMP configuration about OSPF trap sending is correct Please check whether OSPF non virtual interface status changes are to the correct direction if not check if the link connection status and router operation are normal please ospfRouterld router ID used to distinguish the routers in au tonomous system and the value is only value OID 1 3 6 1 2 1 14 1 1 ospfIfIpAddress the IP address at OSPF interface OID 1 3 6 1 2 1 14 7 1 1 ospfAddressLesslf index of interface without address O for inter face with address and ifIndex index for interface without address OID 1 3 6 1 2 1 14 7 1 2 ospfVirtIfState OSPF interface status OID 1 3 6 1 2 1 14 7 1 12 BGP TRAP Message bgpEstablished BGP state machine status is changed to ESTABLISHED status 1 BGP state machine status is changed to ESTABLISHED status 2 The SNMP configuration about BGP trap sending is correct None bgpPeerLastError error number and sub number appeared on BGP peer value O if no error OID 1 3 6 1 2 1 15 3 1 14 bgpPeerState BGP peer status as idle connect and active OID 1 3 6 1 2 1 15 3 1 2 bgpBackward Transition The trap indicates that BGP state machine regresses from high level status to lower level status Confidential and Proprietary Information of ZTE CORPORATION 271 ZXR10 Alarm Handling Manual Triggering Criteria Recommended Operations Binding variab
131. cleared at 01 58 20 01 28 2001 UTC sent by UPC MPU 2 ENVIRONMENT SFC Panel 1 Current local tem perature is 33 C 91F exceeds the low threshold 10 C 13F Board temperature is lower than the set lower threshold T128 T64 T600 T1200 N A 64 64 5 Available Environmental Alarm 4 Board temperature is higher than the set first high temperature threshold The command used to set threshold for equipment temperature is temper threshold UPC master local lowthreshold 20 first high threshold 55 second highthreshold 90 63 65 Decrease board temperature if necessary Decrease the environ ment temperature of the equipment by the fan heat dissipation Alarm Occurred s Panel d Current local temperature is d C dF exceeds the first high threshold d C dF Alarm Cleared Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Related Alarms Recommended Operations Chapter 2 Alarm Message s Panel d Current local temperature is d C dF under the first high threshold d C dF The first s is the board type the first d is the panel number of the board the second d is the centigrade temperature of the board the third d is the Fahrenheit temperature of board the fourth d is the centigrade temperature of the set threshold and the fifth
132. commended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH This is the system prompt 1017 1017 The current unnumber interface has IP address already Please check whether the configuration is proper 1018 1018 Fail in current operation It may try again later 1019 1019 The line board location parameter is wrong Please check whether the command configuration is correct 1020 1020 The board type is wrong Please check whether the input parameter is correct 1021 1021 The interface board already exists This is the system prompt 1022 1022 The interface board does not exist 176 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Chapter 3 Command Configuration Error Prompt Messages This is the system prompt 1024 1024 The debug of IP packet is activated Informational notice No action is needed 1025 1025 The debug of IP packet is deactivated Informational notice No action is needed 1026 1026 The debug of arp packet is activated Informational notice No action is needed
133. config if flow threshold input 100 Set flow threshold output to 100 zxr10 config 1 f low threshold output 100 current output traffic is d over the threshold is d current input traffic is d over the threshold is d The first d current traffic utilization The second d the set traffic utilization 06 18 43 06 19 2002 UTC alarm 18335 occurred IP current output traffic is 90 over the threshold is 85 on fei_8 1 sent by UPC RPU 1 06 18 43 06 19 2002 UTC alarm 18335 occurred IP current input traffic is 90 over the threshold is 85 on fei_8 1 sent by UPC RPU 1 The current ingress egress traffic utilization exceeds the set threshold T128 T1200 IGMP Alarm 18944 18944 6 A member joins IGMP multicast group Confidential and Proprietary Information of ZTE CORPORATION 83 ZXR10 Alarm Handling Manual Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause ZTEDH N A 18945 18945 6 A member leaves IGMP multicast group Check whether related configurations of IGMP protocol are correct and proper and whether any messages about joining and leaving of IGMP group member are received ARP Alarm 19712 19712 6 Dynamic ARP item MAC address
134. cription Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Related Alarms Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Appendix Specification Chapter 2 Alarm Message Available QoSAlarm 4 CPU load namely CPU utilization ratio reaches the set middle threshold It may bring to the slow operation response 16899 16901 If the operation with great consumption on cpu is carried out in short time then it is normal phenomenon Commands show process show process detail can be used to view CPU utilization s M panel d current CPU load is d s S panel d current CPU load is d The first s is CPU type The first d is panel number and the second d is CPU utilization CPU load namely CPU utilization ratio exceeds the set middle threshold All The platform 4 6 03b and the upgrade versions support this alarm Not CE amp PTN version 16901 16901 5 Available QoSAlarm 3 CPU load namely CPU utilization ratio reaches the set high thresh old It may bring to the slow operation response 16899 16900 If the operation with great consumption on cpu is carried out in short time then it is normal phenomenon Commands show process show process detail can be used to view CPU utilization s M panel d current CPU load is d s S panel d current CPU lo
135. cvs cita da 259 Hardware Alarm Trap ccscccceeceeeeeeeeeeeeeeeeeeeeeeaeeaeeaennas 259 Software Alarm TTD idas 260 RMON TRAP MESSAGE iii 261 FISINGAI ANN Trap wie cnien eed Saeed dee anaes held tae lees dee ees 261 fallingAlarM Trapen n eee eee teeta teens 261 OSPF TF RAP MeSSaGes iiss cie ella ac 262 ospfVirtIfStateChange cece ee eee cece eee eee eee eeeeeeeeneees 262 OSPfNbrStateChanGe eceeee cece eee ee eee teense eeeeeeeeneees 262 ospfVirtNbrStateChangGe ccceeeee eee ee eee ee eee eeeeeeneees 263 OSPFIFCONAGEIS ON naia ee a wen nedecenienes 264 ospfVirtIfConfigErroOF 00 cece cece cette eee teen ee aas 264 ospfIfAuthFailure cc cece cece cece e esas eeeeeeeeeeseaeesaneeaanes 265 ospfVirtIfAuthFailure ococcccoccconccnoncnancnnancna cnn nana 266 ospfIfRxBadPacket ococccocccconcnoncnnancnancnna cra cnnannnan cons 266 ospfVirtIfRxBadPacket ooccccocccocccnoncnoncnnoncnancnnannnannnns 267 OSPFTXRetransMit 0cccoccconccnoncnoncnnonnnancnnannnnncnna nana rca 267 OSPFVirtIFTXRetranSmMit 0 ccccoccconccnoncnoncnnancnancnna nana nnnns 268 osptOriginatelS diia 269 OSPIMAXAGELSE viii 269 ospfLsdbOverfloW 00cococccocccnoncnoncnna cnn cnn nn cnn rana 270 ospfLsdbApproachingOvVerflOW cccecceeeeeeesaeeaeeaeeeaes 270 OSPfIFStateChanGe a a aa A a aaa ENA Ea iaa 271 BGP TRAP Message occocccnccnncnnncnncnnnn cnn cnn narrar 271 bgpEstablished ios 271 bgpBackward Transition ccccscceeeeeeee
136. d Please enable tacacs function 28165 28165 5 There is no server available in Tacacs server group Please check whether the configuration of tacacs server is cor rect whether AAA configuration on NAS is correct whether in terconnection between NAS and server is ok whether network communication is normal 28166 28166 5 118 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Chapter 2 Alarm Message The size of Tacacs request packet is overlarge Please modify the max size of tacacs packet disable tacacs function and re enable tacacs 28167 28167 4 Tacacs authentication request is wrong It s an internal error and please contact ZTE engineer 28168 28168 6 Tacacs request packet is timeout Please check whether the configuration of tacacs server is cor rect whether AAA configuration on NAS is correct whether in terconnection between NAS and server is ok whether network communication is normal 28169 28169 6 The authentication type is not supported by NAS client NAS doesn t support authentication of ARAP type AAA Alarms
137. d router ID used to distinguish the routers in au tonomous system and the value is only value OID 1 3 6 1 2 1 14 1 1 ospflfIpAddress the IP address at OSPF interface OID 1 3 6 1 2 1 14 7 1 1 ospfAddressLesslf index of interface without address 0 for inter face with address and ifIndex index for interface without address OID 1 3 6 1 2 1 14 7 1 2 ospfPacketSrc OSPF report IP address unable to be identified by neighbor example OID 1 3 6 1 2 1 14 16 1 4 ospfConfigErrorType the possible types of OSPF configuration er rors as error version number mismatched area number and un known virtual neighbor OID 1 3 6 1 2 1 14 16 1 2 ospfPacketType OSPF packet type hello packet IsReq packet and IsAck packet OID 1 3 6 1 2 1 14 16 1 3 ospfVirtlfConfigError Error OSPF virtual interface configuration 1 The peer parameter configuration at OSPF virtual interface is inconsistent with the relevant configuration of the router 2 The configuration for SNMP related OSPF sending trap is cor rect Please check whether the router configurations related to OSPF protocol are consistent with the opposite end ospfRouterld router ID used to distinguish the routers in au tonomous system and the value is only value OID 1 3 6 1 2 1 14 1 1 ospfVirtIfAreald the area ID crossed by OSPF virtual connection OID 1 3 6 1 2 1 14 9 1 1 264 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Inform
138. d the second d is the Fahrenheit temperature of board the third d is the centigrade temperature of the set threshold and the fourth d is the Fahrenheit temperature of the set threshold An alarm 69 level 5 occurred at 02 02 40 01 28 2001 UTC sent by UPC MPU 2 ENVIRONMENT SFC Panel 1 Current remote temperature is 51 C 123F exceeds the second high thresh old 50 C 122F An alarm 69 level 5 cleared at 02 02 50 01 28 2001 UTC sent by UPC MPU 2 ENVIRONMENT SFC Panel 1 Current remote temperature is 51 C 123F under the second high thresh old 100 C 212F The remote temperature is higher than the set remote second high threshold of the board T128 T64 T600 T1200 N A 73 73 5 Available Environmental Alarm 4 16 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Cause Influence Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Prototype Description Chapter 2 Alarm Message The rack temperature is higher than the set single high threshold This leads to the abnormal working of the switch Lower the environment temperature of the rack by using fan heat dissipation Alarm occured Current temperature is the thresh old dC dF Alarm cleared Current temperature is dC dF under the thr
139. dcast re port OID 1 3 6 1 2 1 14 4 1 4 ospfMaxAgeLsa LSA reaches the maximum aging time on router link status data base 1 LSA reaches the maximum aging time on router link status database 2 The SNMP configuration about OSPF trap sending is correct None ospfRouterld router ID used to distinguish the routers in au tonomous system and the value is only value OID 1 3 6 1 2 1 14 1 1 ospfLsdbAreald the area ID of router value 0 0 0 0 for outside of autonomous system OID 1 3 6 1 2 1 14 4 1 1 ospfLsdbType link status broadcast type router link network link and group broadcast link OID 1 3 6 1 2 1 14 4 1 2 ospfLsdbLsid link status ID formed by router ID or IP address Confidential and Proprietary Information of ZTE CORPORATION 269 ZXR10 Alarm Handling Manual ZTEHX Information Description Triggering Criteria Recommended Operations Binding variables Information Description Triggering Criteria Recommended Operations Binding variables OID 1 3 6 1 2 1 14 4 1 3 ospfLsdbRouterld router ID originating link status broadcast re port OID 1 3 6 1 2 1 14 4 1 4 ospfLsdbOverflow LSA database overflow trap 1 LSA quantity on link status database exceeds the maximum value of the external link status database 2 The SNMP configuration about OSPF trap sending is correct Check whether the router configuration is proper and the permitted router performance parameters
140. e Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages Check whether the topology is proper 2058 2058 The OSPF neighbor address is a local address Please input the correct configuration parameter 2059 2059 Please input the clear ip ospf process command to activate the configuration Execute the command clear ip ospf process 2060 2060 The reference bandwidth is changed Please make sure that the reference bandwidth is consistent in all routers Please confirm the reference bandwidth is consistent in all routers 2200 2200 The vrf command does not match the OSPF example Please check whether the command configuration is correct 2801 2801 The backbone area cannot be configured as an NSSA area Confidential and Proprietary Information of ZTE CORPORATION 197 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH This is the system prompt 2802 2802 The stub area cannot be configured as an NSSA area This is the system prompt 2803 2803 The ZXR10 router have only one NSSA area This is the system prompt
141. e MA eS 121 A E E es 121 29954 anera cave aE pLa eae ilev dae ee ecu ee cba od 121 29955 A At 122 2995 Bytes readustinensinit a 122 DOOD Te nian deca 123 29958 a 123 209959 AA ewes veces is 124 29 9G 0 ET nada diy ash dadeva eae TE 124 BED MAMA A A 125 SO 208 a hanes A esl neuen eee tt 125 3021 Zi 127 SO213 A aa 127 UDLD Alda a a eset 128 LI A A adaes dees E 128 29697 AA A Neal 128 29098 it AR AAA A A 129 29699 A lo aie 129 MUX Alarm ck sagas eevee th aide awed nies eG 130 294940 wari ia aa ad aa aa tetas ds 130 ZESS Ala M perene nean a 130 A A AAN 130 A A Sea canta eae ves eee ies 131 S25 Ai A AAA ed AAA AAA ot 131 POE Alara ipi a p ANE E E 132 UL en dd aa 132 A O A OS 133 ESM Alai na 134 DO OD A aie alsa AANA 134 EPONAdA MA RG isa aks oe Sea a 134 CEPA il pein deed teed eaten 134 3328 Ui iis ccdvigeidseat a E ede diac reeked 135 TIROL A dela itive ext tele doly 136 TIRO 2 dde cer wedecncays ita 137 33284 a a Od 137 BS 28D AAA 138 33286 sissies eave a eee 138 S328 7 sheacdivladusWandate dled EA N ARAA 139 a TE 140 E A AN 140 IL da A A IIA 141 3329 ii A eee 142 33 29 La Dai as lola 142 IIA er Cee eR Me car eo a e 143 A iiavania dalam TE 143 33295 E 144 33296 posi AN 144 BO297 wit nies sacs as ck ees Vea ads 145 Command Configuration Error Prompt Messages o ccccooonnnnoccnnonnnnnnnnoncnnnnnannnanannnnananass LOZ Error Message Descripti0N cccecee cece e eee tenet eee NANNA 147 A OO 147 A A y aaah Yee veal Ma
142. e en abled Other protocols need to be configured to avoid loop other wise it will cause network storm 69 89 Switches LOCAL ACCOUNTING Alarm 24832 24832 6 Accounting cache of local storage exceeds alert value Check whether the communication between UAS and accounting server is normal LDP Alarm 25344 25344 6 Two different types of pw spoke and hub are configured in one vfi Confidential and Proprietary Information of ZTE CORPORATION 111 ZXR10 Alarm Handling Manual Recommended Operations Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Severity Level Cause ZTEDH Check whether the newly configured pw generates loop If there is loop delete this pw configuration Otherwise ignore this alarm 25347 25347 3 Available CommunicationAlarm It is suggested that NM not show this alarm to user 5 LDP neighbor is down Corresponding LSP changes to untagged and packets can t be de livered according to tag Check whether LDP configurations is changed and whether related direct connect link is down Alarm occurred LDP neighbor s is DOWN pre state s state s status code d Alarm cleared LDP neighbor s is UP pre state s state s status code d The first s LDP ID The second s the sess
143. e if necessary Decrease the environ ment temperature of the equipment by the fan heat dissipation Stop using the board if the temperature is too high Confidential and Proprietary Information of ZTE CORPORATION 11 ZXR10 Alarm Handling Manual Alarm Prototype Description Alarm Description Supported Devices 12 Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Recommended Operations ZTEDH Alarm Occurred s Panel d Current local temperature is d C dF exceeds the second high threshold d C dF Alarm Cleared s Panel d Current local temperature is d C dF under the second high threshold d C dF The first s is the board type the first d is the panel number of the board the second d is the centigrade temperature of the board the third d is the Fahrenheit temperature of board the fourth d is the centigrade temperature of the set threshold and the fifth d is the Fahrenheit temperature of the set threshold Alarm Occurred s Current local temperature is d C dF exceeds the second high threshold d C dF Alarm Cleared s Current local temperature is d C dF under the second high threshold d C dF The first s is the board type and is fixed to BIC board There is no panel number on BIC board so the display format is different from other board the first d is the centigrade temperature of the board the second d is the
144. ease check whether the command and command parameters are correct 6021 6021 Error command ID of received command message Please check whether RMON supports the command and whether the command configuration is correct 6022 6022 Error command parameter Please check whether the input command parameter is valid and proper 214 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Chapter 3 Command Configuration Error Prompt Messages 6023 6023 The received command parameter quantity is wrong Please check whether the input parameter is correct 6024 6024 The index is wrong Please check whether the command parameter and command con figuration are correct 6025 6025 Fail to distribute buffer Please check whether the RMON configuration reaches the maxi mum system value and try again later 6026 6026 Module conflict Please check if the command configuration is correct and try again later 6027 6027 Error ingress deletion index not existed or mismatched Please check if the command parameter is correct 6028 6028 Confidential and Proprietary Information of ZTE CORPORATION 215 ZXR10 Alarm Handling
145. eb ee 88 19983 id pt 89 RMON Al Mii 90 A aivsnuden TT 90 LILIA A sO eM Sas ease en eevee eee oe 90 DOTS T sae cde A ARA AA A Rees tt 90 DUI a ica 91 20759 ruaa eia E EAA OR AES 91 DOT A A aces ca hg A 91 A E st teuceededscaane des 91 URPF Alicia A A a eevee 92 DADAS A A ET 92 AELA MAA 92 DVT G2 O T dee VO 92 21764 eiside A Wea eae ies 92 Di aaa 92 A A E sche ieaanadeee tea tas 93 QT 1D ad aati een hala ata Wunder utente rene setae 93 DAFT Oeste Mois Seu dings ds avait A weer ded ace veuaat 93 2177 ai a AAA tas dade uted eek aes eas 94 VRRP Ala Mina 95 BLOOD it AA AAA E 95 MAG AAI iii ii 95 22784 ei visitas aca daa ian tana awe A E RR 95 2278 ON eatin Aicioknd ition naeiaaia T 95 227 BG ii 95 OILY Bod MPEP AAA 96 D271 BS A cine sens aa cies 96 DEPOR OA ies tee ene nz 96 22790 Re ee TA RTT SATE EERE PoP EME or Eee 96 22 LS EERE RET A REC TERE A Eee 96 22793 vivecxauninuwexvacixen a aaa 97 22794 RT 97 227 OD wate oie Se a AN le oN SA Sits SA 98 227 9G voces taecnnda sienna watinsa urn TN 98 DELI tri ARA vides AA AA OA eben ede 99 A tweeter E 99 LOOP DELO CEdiimiici A did aisle enuiidls ce ead eile te centlaneie 100 23296 NR NE 100 DHCP Alar iviisccercs cites ate na 100 23808 it wives ean avvaveniedwexvedee is 100 23809 a es 100 23810 erik eatin Scent weak in ince savas ree ieateh es 101 LIS donee A da 101 Zi 103 ZO Di tas 104 PAA E o EA E A Sa seat Sa es eA 104 PI S T EAE sick antadh dees N 105 LIO dt A ere date ENA ees a
146. eceive direction of local data terminal device This alarm is called local link fault alarm in EPON project In de fault this alarm is enabled If the alarm need to be disabled con figure alarm local link fault disable on OLT interface Epon alarm local link fault occour Example 14 57 30 08 26 2008 UTC alarm 33289 occurred EPON Epon alarm local link fault occour sent by NPC 3 Fault occurs on the link in receive direction of EPON local data terminal device EPON project of 4822 33290 33290 5 CommunicationAlarm 4 It s a data loading fault or other dying gasp fault Or fault occurs in receive direction of local data terminal device The optical path is abnormal 33288 33289 Disconnect and re connect the connection between ONU and OLT Register ONU again This alarm is called critical event alarm in EPON project In default this alarm is enabled If the alarm need to be disabled configure alarm critical event disable on OLT interface Epon alarm critical event occour Example 14 57 30 08 26 2008 UTC alarm 33290 occurred EPON Epon alarm critical event occour sent by NPC 3 It s a data loading fault or other dying gasp fault Or fault occurs in receive direction of local data terminal device EPON project of 4822 Confidential and Proprietary Information of ZTE CORPORATION 141 ZXR10 Alarm Handling Manual Message No Default Security Level Alarm Type NM Level Cause Influe
147. eck whether the interface state is changed RIP Alarm 17664 17664 6 RIP module fails to apply for the memory distribution Please check whether the system memory utilization reaches the top and the system configuration information reaches or exceeds the permitted limits If it reaches the top consider to upgrade the equipment If the system memory utilization does not reach the top please contact ZTE maintenance staff 17666 17666 6 RIP module fails to create timer If the problem appears during command configuration it may at tempt a few minutes later Please record the fault phenomenon and contact ZTE maintenance staff in time 17667 17667 6 RIP route table is full and unable to add more RIP routes and new neighbors Please check whether the configuration related to RIP protocol is correct and proper and whether the system running state is nor mal 17670 17670 6 The RIP neighbor is not on the same subnet or the neighbor ad dress is a network broadcast address Confidential and Proprietary Information of ZTE CORPORATION 57 ZXR10 Alarm Handling Manual Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations ZTEDH Plea
148. elay layer 3 interface If it is the local address then configure the DHCP Relay server again relay server s is local vrrp addr sIP address of DHCP Relay Server Alarm occurred 13 21 28 07 17 2008 UTC alarm 23816 occurred DHCP relay server 100 1 1 1 is local IP addr sent by NPC 2 104 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Description Supported Devices Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Chapter 2 Alarm Message DHCP Relay Server address is the local address in the L3 interface that the DHCP users access ZXR10 3900 5900 6900 series switch T64E T128 T600 T1200 series router 23817 23817 6 Unavailable ProcessingErrorAlarm 5 DHCP Relay Server address is the local address in the L3 interface that the DHCP users access Check whether the DHCP destination is reachable and whether the configuration is correct ailed to send s from s to s s The first s Packet type of DHCP The second s source ip address The third s dest ip address The fourth s the reason of failure Alarm occurred 17 24 09 07 17 2008 UTC alarm 23817 occurred DHCP failed to seng DHCPDISCOVER from 100 1 1 1 to 100 1 2 1 no route sent by NPC
149. ended Operations Alarm Prototype Description Alarm Description Supported Devices Chapter 2 Alarm Message 23813 23813 6 Unavailable ProcessingErrorAlarm 5 DHCP Relay agent address is not the local interface address in the L3 interface that the DHCP users access The user in L3 interface can not obtain the IP address Check whether the DHCP Relay agent address and the DHCP Relay layer 3 interface address is matching relay agent s is not s add The first s DHCP Relay agent address The second s L3 interface name of user access interface Alarm occured 14 03 33 07 16 2008 UTC alarm 23813 occurred DHCP relay agent 100 1 1 1 is n ot vlan100 addr sent by NPC DHCP Relay agent address is not the local interface address in the L3 interface that the DHCP users access ZXR10 3900 5900 6900 series switch T64E T128 T600 T1200 series router 23814 23814 6 Unavailable ProcessingErrorAlarm 5 The set DHCPRelayserver is invalid The user in L3 interface can not obtain the IP address Check whether the DHCP Relay Server address is configured in DHCP Relay layer 3 interface relay have no valid server configure Alarm occurred 14 23 17 07 16 2008 UTC alarm 23814 occurred MLD relay have no valid server configure sent by NPC 2 DHCP Relay Server address is not configured in the L3 interface that the DHCP users access ZXR10 3900 5900 6900 series switch Confidential and Proprietary Infor
150. ended Operations Message No Default Severity Level Chapter 2 Alarm Message If possible restart the line board where the interface is located 18720 18720 6 The interface is up Informational message No action is reqiured 18721 18721 6 The interface is down Check whether the interface cable is well and the system running is normal 18722 18722 4 When establishing the interface the programe fails to establish database nodes which brings to mistakes on interface info Look over the database nodes and confirm whether they run out of use Please stop establishing interfaces if database nodes are used up 18737 18737 6 Receive the packet of undefined type Check whether the network running is well and the system config uration is proper 18738 18738 6 Confidential and Proprietary Information of ZTE CORPORATION 77 ZXR10 Alarm Handling Manual Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level ZTEDH The IP header length of received packets is too short Check whether the network running is well 18739 18739 6 The length of received IP packets is w
151. eshold dC dF The first d is the environment Centigrade degree the second d is the Fahrenheit degree the third d is the environment Centigrade degree of the set threshold the fourth d is the envi ronment Fahrenheit degree of the set threshold dC Y dF exceeds Alarm occured 16 20 31 06 26 2008 UTC alarm 73 occurred ENVIRON MENT Current temperature is 90C 194F exceeds the thresh old 80C 176F Alarm cleared 16 22 11 06 26 2008 UTC alarm 73 cleared ENVIRONMENT Current temperature is 80C 176F under the threshold 90C 194F The rack temperature is higher than the set single high threshold ZXR10 3900 3200 5900 5200 and G series switch N A 74 74 5 Available Environmental Alarm 3 The power works abnormally This leads to the abnormal working of the switch Check whether the power input is normal and whether the rack output is normal whether the power module is plugged correctly whether the connection is OK Alarm occured Power d do not work Alarm cleared Power d restart d the power serial number Multiple power states can be dis played simultaneously UAS10800E Confidential and Proprietary Information of ZTE CORPORATION 17 ZXR10 Alarm Handling Manual Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Prototype Description 18 ZT
152. essage No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No ZTEDH Please input the correct command parameter 207 257 There are too many symbols nested in the rule expression Please input the correct command parameter 258 258 The range in the rule expression is illegal Please input the correct command parameter 259 259 The range in the rule expression is mismatched Please input the correct command parameter 260 260 The content after and in the rule expression cannot be vacant Please input the correct command parameter 261 261 There are other errors in the rule expression Please input the correct command parameter 262 262 166 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Chapter 3 Command Configuration Error Prompt Messages AllView and DefaultView figures cannot be modified or deleted AllView and DefaultView figures are system default figures which cannot be modified or deleted 263 263 The next hop address is illegal Please input the correct command para
153. essage No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH Please try again later 7023 7023 Incorrect database path location Please try again later 7024 7024 The database process is busy Please try again later Please try again later 7030 7030 Incorrect command parameter quantity Please input the correct command parameter 7031 7031 Error command parameter Please check if the input parameter is correct 7032 7032 Error command message ID Please check whether the system supports this command 7040 7040 The main log switch is turned off 224 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages Please turn on the main log switch first 7041 7041 FTP host address is blank Please configure correct command 7042 7042 trap host address is blank Please configure correct command 7050 7050 Error timer ID Please check whether the system is running norma
154. essage No NM Level Cause Recommended Operations Message No NM Level Cause Recommended Operations Message No NM Level Cause ZTEDH 22787 22787 6 Turn into protection status Check whether the protection is configured and whether anybody attacks balefully 22788 22788 6 Exit the protection status Check whether the protection is configured and whether anybody attacks balefully 22789 22789 6 MAC address shifts from one port to other port Check whether loop exists If not then check whether the same MAC address exists on different ports 22790 22790 6 State changes of spanning tree if the specific instance under spe cific port changes from forwarding state to blocking state dynamic MAC address of this port will be deleted N A 22792 22792 6 Outgoing interface of MAC address or inner outgoing tag changes 96 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Default Security Level Alarm Recovery Alarm Type NM Level Cause Influence Related Alarms Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Message No Default Security Level Alarm Recovery Alarm Type NM Level Cause Influence Related Alarms Recommended Operations Alarm Description Prototype Chapter 2 Alarm Message Check whether there is any loop 22793 22793 6 None
155. etary Information of ZTE CORPORATION 87 ZXR10 Alarm Handling Manual Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No ZTEDH Check whether the system configuration is correct 19978 19978 6 Fail to add IS IS route Check whether the system running status is normal and the sys tem configuration is proper 19979 19979 6 Fail in IS IS memory allocation Check the system running status If possible save the system configuration information and then restart the system 19980 19980 6 When ISIS runs TE path calculation if no LSP entry or multiple corresponding LSP entries are found according to one given router id this alarm will be generated Check the network configuration Check whether the same TE router id is configured on multiple routers or whether this TE router id is configured on no router 19981 19981 6 When ISIS is in GR process if system control module doesn t sup port this boot mode this alarm will be generated Check whether the hot standby state of support module is correct 19982 19982 88 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Default Severity Level
156. evel Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause ZTEDH 6 Fail to transmit OPEN report Check whether the port is operating normally 17952 17952 6 Fail to transmit KEEPALIVE report Check whether the port is operating normally 17953 17953 6 Fail to transmit NOTIFICATION report Check whether the port is operating normally 17954 17954 7 Fail to transmit UPDATE reachable report None and system will try again one second later 17955 17955 7 Fail to transmit UPDATE unreachable report None and system will try again one second later 17956 17956 6 SPOOL tries to send other report when it is not idle 64 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Chapter 2 Alarm Message Check whether the port is operating normally 17957 17957 6 Fail to create SPOOL Please check whether the system operati
157. evice Alarm occurred 00 05 49 01 01 2001 UTC alarm 16920 occurred OAM STOR file flash 1 txt sent by MCP 16921 16921 6 The ftp user copies files on the device Alarm occurred 00 04 25 01 01 2001 UTC alarm 16921 occurred OAM RETR file flash hes59 bin sent by MCP 16922 16922 6 The ftp server fails to send message Alarm occurred 00 07 21 01 01 2001 UTC alarm 16922 occurred OAM Send message to protocol error by MCP Check whether FTP server configuration is correct and whether the connection is well 16923 16923 6 ProcessingErrorAlarm 4 After enabling DHCP the switch will download configuration file through TFTP circularly When retry time is 10 about 4 5 min utes version is not downloaded Inform user of failure of downloading and suggest downloading again Stop DHCP automatic download configuration file function Confidential and Proprietary Information of ZTE CORPORATION 49 ZXR10 Alarm Handling Manual Alarm Description Prototype Alarm Description Supported Devices Message No Default Security Level Alarm Recovery Alarm Type NM Level Cause Influence Related Alarms Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Message No Default Security Level Alarm Recovery ZTEDH Auto download config file fail Example 00 57 29 01 01 2001 UTC alarm 16923 occurred OAM Auto download config file fail sent by MCP
158. evice If system 120 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Chapter 2 Alarm Message memory utilization doesn t reach the max please contact ZTE en gineer MIX Alarms 29952 Message No 29952 Default Severity 3 Level Cause If the alarm state is occurred it indicates the alarm has occurred The general reason is main board detects that communication with other card breaks and the card doesn t work In case alarm state is Cleared it indicates the alarm has been cleared The general reason is main board detects that communication with other card is ok and the card works normally Recommended In case alarm state is Occurred please check if this card works Operations normally Alarm ProtoType Alarm occurred Description 10 12 57 09 15 2006 UPC alarm 29952 occurred Mp check np 1 communication failed sent by UPC 1 Alarm cleared 10 12 59 09 15 2006 UTC alarm 29952 cleared Mp check np 1 communication succeeded sentbyUPC1 29953 Message No 29953 Default Severity 6 Level Cause In case alarm state is Occurred it indicates the alarm has oc curred Generally the reason is router is attacked by TCP SYN Flood Alarm ProtoType Alarm occurred Description 00 00 12 01 01 2001 UTC alarm 29953 occurred MIX The router is attacked by tcp syn flood sent by MCP 29954 Message No 29954 Default Severity 6 Level Confidential and Proprietary Information of ZTE CORPORATI
159. f ZTE CORPORATION ZTEDH Chapter 1 Alarm Overview 10 12 57 09 15 2003 UTC alarm 512 occurred PORT Port Down on fei_5 6 sent by SMP 1 Port alarm alarm cleared 10 12 59 09 15 2003 UTC alarm 512 cleared PORT Port Up on fei_5 6 sent by SMP 1 2 Software alarm gt BGP alarm 10 12 58 09 15 2003 UTC alarm 17959 occurred BGP 2d18h BGP 100 1 1 1 went from Idle to Connect sent by SMP 1 Confidential and Proprietary Information of ZTE CORPORATION 7 ZXR10 Alarm Handling Manual ZTEHX This page is intentionally blank 8 Confidential and Proprietary Information of ZTE CORPORATION Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Related Alarms Recommended Operations Alarm Prototype Description Chapter 2 Alarm Message Table of Contents Hardware alias 9 SoftWare AMM aa 30 Hardware alarm Environment Alarm 63 63 Available Environmental Alarm 4 Board temperature is lower than the set lower threshold The command used to set threshold for equipment temperature is temper threshold UPC master local lowthreshold 20 first high threshold 55 second highthreshold 90 64 65 Increase environmental temperature of equipment if necessary Alarm Occurred s Panel d Current local temperature is d C dF under the low threshold d C dF Alarm Cleared s Panel d Current local temperature is d C dF exceeds the low threshold d
160. for interface without address Confidential and Proprietary Information of ZTE CORPORATION 267 ZXR10 Alarm Handling Manual ZTEHX Information Description Triggering Criteria Recommended Operations Binding variables OID 1 3 6 1 2 1 14 7 1 2 ospfNbrRtrId the router ID of OSPF neighbor router OID 1 3 6 1 2 1 14 10 1 3 ospfPacketType OSPF packet type hello packet IsReq packet and IsAck packet OID 1 3 6 1 2 1 14 16 1 3 ospfLsdbType link status broadcast type router link network link and group broadcast link OID 1 3 6 1 2 1 14 4 1 2 ospfLsdbLsid link status ID formed by router ID or IP address OID 1 3 6 1 2 1 14 4 1 3 ospfLsdbRouterld router ID originating link status broadcast re port OID 1 3 6 1 2 1 14 4 1 4 ospfVirtlfTxRetransmit OSPF report is transferred on OSPF non virtual interface 1 The report received at the OSPF non virtual interface is trans ferred 2 The SNMP configuration about OSPF trap sending is correct None ospfRouterld router ID used to distinguish the routers in au tonomous system and the value is only value OID 1 3 6 1 2 1 14 1 1 ospfVirtIfArealId the area ID crossed by OSPF virtual connection OID 1 3 6 1 2 1 14 9 1 1 ospfVirtIfNeighbor the router ID of OSPF virtual neighbor OID 1 3 6 1 2 1 14 9 1 2 ospfPacketType OSPF packet type hello packet IsReq packet and IsAck packet OID 1 3 6 1 2 1 14 16 1 3 ospfLsdbType link status broad
161. fth d is the Fahrenheit temperature of the set threshold Alarm Occurred s Current remote temperature is d C dF exceeds the first high threshold d C dF Alarm Cleared s Current remote temperature is d C dF under the first high threshold d C dF The first s is the board type and is fixed to BIC board There is no panel number on BIC board so the display format is different from other board the first d is the centigrade temperature of the board the second d is the Fahrenheit temperature of board the third d is the centigrade temperature of the set threshold and the fourth d is the Fahrenheit temperature of the set threshold An alarm 68 level 5 occurred at 02 01 50 01 28 2001 UTC sent by UPC MPU 2 ENVIRONMENT SFC Panel 1 Current remote tem perature is 51 C 123F exceeds the first high threshold 40 C 104F An alarm 68 level 5 cleared at 02 02 10 01 28 2001 UTC sent by UPC MPU 2 ENVIRONMENT SFC Panel 1 Current remote tem perature is 51 C 123F under the first high threshold 53 C 127F The remote temperature is higher than the set remote first high threshold of the board T128 T64 T600 T1200 N A 69 69 5 Available Environmental Alarm 3 The remote temperature is higher than the set remote second high threshold of the board The command used to set threshold for equipment temperature temper threshold UPC master local lowthreshold 20 first high threshold 55 second highthreshold 90 67
162. g configuration is still in process sent by UPC MPU 1 Telnet executes write terminal 10 59 29 06 27 2007 UTC alarm 16918 occurred OAM Vty 1 is closed but writing configuration is still in process sent by UPC MPU 1 The terminal number after vty keeps consistent with the one after command who Please do not restart the rack in order to prevent the created startrun not complete Reboot operation may lead to the loss of rack configuration or the command line error Use dir to con firm whether startrun file is updated 16919 16919 6 FTP users delete the files on the device Alarm occurred 00 07 21 01 01 2001 UTC alarm 16919 occurred OAM DELE file flash 1 txt sent by MCP Please do not restart the rack in order to prevent the created startrun not complete Reboot operation may lead to the loss of rack configuration or the command line error Use dir to con firm whether startrun file is updated 16920 16920 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Default Severity Level Cause Alarm Prototype Description Message No Default Severity Level Cause Alarm Prototype Description Message No Default Severity Level Cause Alarm Prototype Description Recommended Operations Message No Default Security Level Alarm Type NM Level Cause Influence Recommended Operations Chapter 2 Alarm Message 6 The ftp user uplosds files to the d
163. ge No Cause Chapter 3 Command Configuration Error Prompt Messages Informational notice No action is needed 1035 1035 The same tag value exists Please check whether the input parameter is correct 1036 1036 Illegal mtu value Please check whether the input parameter value range is legal 1037 1037 The destination address is the local address itself Please configure correct command 1038 1038 The selection packet header length is too short and illegal Please input the correct parameter and try again later 1039 1039 The address and mask are mismatched Please configure correct command 1040 1040 The option length is incorrect Confidential and Proprietary Information of ZTE CORPORATION 179 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations ZTEDH Please configure correct command 1041 1041 illegal source Please input the correct command parameter and try again later 1042 1042 The interface has no host address Please input the correct parameter 1043 1043 Auxiliary addresses exist Delete all the auxiliary addresses first 1044 1044 The ip unnumber attribution of interface exists Please remove the ip u
164. ge No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages Please input the correct parameter 1001 1001 The interface does not exist Please check whether the input parameter is correct 1002 1002 The same network section IP address already exists Please input the correct parameter 1003 1003 Incorrect IP address mask Please input the correct parameter 1004 1004 Incorrect IP broadcast address is input Please input the correct parameter 1005 1005 Fail to add IP address Please check whether the parameter is correct and try again later 1006 1006 Fail to delete IP address Confidential and Proprietary Information of ZTE CORPORATION 173 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH Please check whether the parameter is correct and try again later 1007 1007 The input IP address does not exist Please input the correct parameter 1008 1008 Fail to add IP address route Please check whether the parameter is correct and try again later 1009 1009 Fail to delete IP address route Please check whether the parameter is correct and t
165. ging alarm command if there is copy the important alarm message for backup Set alarm log buffer size by using command logging buffer lt buffer size gt buffer size is the size of alarm buffer 100 1000 200K by default 16643 16643 5 The alarm buffer overflows Some old alarm messages will be cleared If alarm message is needed export alarm message at first Set alarm log buffer size by using command logging buffer lt buffer size gt buffer size is the size of alarm buffer 100 1000 200K by default 16644 16644 3 The alarm buffer overflows Some old alarm messages will be cleared If alarm message is needed export alarm message at first Set alarm log buffer size by using command logging buffer lt buffer size gt buffer size is the size of alarm buffer 100 1000 200K by default 16645 16645 3 The standby board fails to acquire the main board database file via FTP Check the system running status necessary Restart the standby board if 16646 16646 3 The node recursion level is too deep in the program to delete the database Confidential and Proprietary Information of ZTE CORPORATION 43 ZXR10 Alarm Handling Manual Recommended Operations Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Related Alarms Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Appendix Specificat
166. gured in dhcp policy Alarm occurred 20 22 09 08 13 2008 UTC alarm 23822 occurred DHCP DHCP policy validPolicy not bound dhcppool sent by UPC RPU 2 Dhcppool is not configured in dhcppolicy All 23823 23823 4 Unavailable ProcessingErrorAlarm 5 Ippool is not configured in dhcppool Users can not get online Please check the DHCPPOLICY configuration Enable DHCPPOLICY debug DHCPPOOL debug can obtain more detailed information DHCP policy bound invalid dhcppool s s dhcp pool name configured this dhcppool not exist Alarm occurred 20 24 35 08 13 2008 UTC alarm 23823 occurred DHCP DHCP policy bound invalid dhcppool invalidPool sent by UPC RPU 2 Invalid dhcppool All 23824 23824 4 Unavailable ProcessingErrorAlarm 5 108 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Cause Influence Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Severity Level Cause Influence Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Chapter 2 Alarm Message Ippool is not configured in dhcppool Users can not get online Please check the DHCPPOLICY configuration Enable DHCPPOLICY debug DHCPPOOL debug can obtain more detailed information DHCP pool s not bound ippool sdhcppool name dhcppool not bound ippool Alarm occurred 20
167. h exceeds the system memory scope Please delete the unavailable policy route and reconfigure it 18787 18787 4 Too many ACL is applied in one line card No ACL can be applied in this line card unless to release one ACL 18790 18790 4 Too many ACL regulation is applied in one line card Delete some ACL regulation in this line card or delete some ACL on this line card 18791 18791 80 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Chapter 2 Alarm Message Too many ACL regulation is applied in one line card If alarm disappears after a while then it means that instant mem ory occupancy is too much It makes no influence If alarm sus tains check whether memory occupancy reaches the maximum and the configuration information reaches or exceeds the thresh old If the memory occupancy reaches the threshold please up grade the device Or contact with ZTE corporation 18794 18794 4 ACL module of NPC fails to dispose message This alarm is a prompt It is usually caused by instant busyness of interior communication This alarm disappears later If the alarm
168. hbor OID 1 3 6 1 2 1 14 9 1 2 ospfConfigErrorType the possible types of OSPF configuration er rors as error version number mismatched area number and un known virtual neighbor OID 1 3 6 1 2 1 14 16 1 2 ospfPacketType OSPF packet type hello packet IsReq packet and IsAck packet OID 1 3 6 1 2 1 14 16 1 3 ospflfRxBadPacket Fail to resolute OSPF report received at OSPF non virtual interface 1 Fail to resolute OSPF report received at OSPF non virtual inter face 2 The SNMP configuration about OSPF trap sending is correct Please check whether the link between routers is perfect and the router configuration at two sides is consistent correct and proper ospfRouterld router ID used to distinguish the routers in au tonomous system and the value is only value OID 1 3 6 1 2 1 14 1 1 ospflfIpAddress the IP address at OSPF interface OID 1 3 6 1 2 1 14 7 1 1 ospfAddressLesslf index of interface without address 0 for inter face with address and ifIndex index for interface without address OID 1 3 6 1 2 1 14 7 1 2 266 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Information Description Triggering Criteria Recommended Operations Binding variables Information Description Triggering Criteria Recommended Operations Binding variables Chapter 4 TRAP Messages ospfPacketSrc OSPF report IP address unable to be identified by neighbor example OID 1 3 6 1
169. he interface Please check whether the command configuration is proper and correct 8919 8919 The interface PVC quantity reaches the upper limit unable to cre ate PVC any more Confidential and Proprietary Information of ZTE CORPORATION 241 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations 242 ZTEDH This is the system prompt 8951 8951 Fail to create multi link Please try again later 8952 8952 Fail to find main connection Please check whether the command configuration is correct 8953 8953 Fail to bind on different line boards Please check whether the command configuration is proper and correct 8954 8954 There are too many members at buddle Please check whether the command configuration is correct 8955 8955 Fail to find main connection Please check whether the command configuration is proper and correct Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No C
170. he second s and the third s source MAC address and desti nation MAC address Example 1 00 16 14 01 01 2001 UTC alarm 16131 occurred ETHOAM Interface occur remote link fault localmac 00d0 d0c6 5e27 peermac 00d0 d0c0 7d81 on fei_1 1 sent by NPC 1 00 16 14 01 01 2001 UTC alarm 16131 occurred ETHOAM Interface occur remote dying gasp event localmac 00d0 d0c6 5e27 peermac 00d0 d0c0 7d81 on fei_1 1 sent by NPC 1 00 16 14 01 01 2001 UTC alarm 16131 occurred ETHOAM Interface occur remote critical event localmac 00d0 d0c6 5e27 peermac 00d0 d0c0 7d81 on fei_1 1 sent by NPC 1 00 16 14 01 01 2001 UTC alarm 16131 occurred ETHOAM Interface occur local link fault localmac 00d0 d0c6 5e27 peer mac 00d0 d0c0 7d81 on fei_1 1 sent by NPC 1 00 16 14 01 01 2001 UTC alarm 16131 occurred ETHOAM Interface occur local dying gasp event localmac 00d0 d0c6 5e27 peermac 00d0 d0c0 7d81 on fei_1 1 sent by NPC1 00 16 14 01 01 2001 UTC alarm 16131 occurred ETHOAM Interface occur local critical event localmac 00d0 d0c6 5e27 peermac 00d0 d0c0 7d81 on fei_1 1 sent by NPC1 Confidential and Proprietary Information of ZTE CORPORATION 33 ZXR10 Alarm Handling Manual ZTEHX Alarm Description Supported Devices Message No Default Security Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype 7 00 16 14 01 01 2001 UTC alarm 16131 occurred ETHOAM Interface occur error frame e
171. her the command configuration is correct 9607 9607 The addresses quantity exceeds 100 Please check whether the command parameter is correct and proper 12401 12401 The number of Template exceeds the maximum value Delete some unused Template 12402 12402 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Chapter 3 Command Configuration Error Prompt Messages Nat ip is configured in Template of the fire wall which will be deleted Delete Nat ip which is configured in Template of fire wall 12403 12403 This Template doesn t exist Create Template first 12404 12404 The interface board is not a firewall interface board Verify the type of the interface board 12405 12405 The configured Nat ip exceeds the maximum value Don t configure more Nat ip or delete some useless Nat ip 12406 12406 This Template doesn t bind FW board or DPI board Bind FW board or DPI board first 12407 12407 This Template has been bound with other Vlan Confidential and Proprietary Information of ZTE CORPORATION 251 ZXR10 Alarm Handling Manual Recommended Operations Mes
172. ices the system privilege password file and catolog setup ii The configuration can not satisfy the system requirments the system capability and capacity decrease caused by con figuration error Especially if the alarm threshold is set by users proper configuration is strongly required 5 The malfunction on the other end device also generates alarms Confidential and Proprietary Information of ZTE CORPORATION 3 ZXR10 Alarm Handling Manual ZTEHX Related Alarms If there is some alarms that are related to this one such as the source alarm that generates this one and the alarms caused by this one please list them Recommended Operations This section lists the recommended operations that can remove the alarms 1 The general analysis methods for the alarms are as follows i Read the alarm message information description carefully and refer to the related content in this manual ii Check whether the network connection is normal using net work commands such as ping telnet netstat ipconfig if config route trace tracert and so on View the related data configuration directly to check whether there is error missed or unreasonable configura tions iv For more difficult problems analyse them with the net work protocol analysis software sniffer v For possible hardware malfunction replace this hardware with the same available hardware to help the manager to determine whether the malfunction is fro
173. ich shows above 34 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Description Supported Devices Appendix Specification Message No Default Security Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype Chapter 2 Alarm Message all remote MEPs RDI defect disappear when alarm disappears the alarm is the content which shows above Example 1 10 38 07 08 10 2009 UTC alarm 30464 occurred CFM MD 1 MA 1 MEP 2 has received a packet from some remote MEPs with RDI flag 2 10 38 10 08 10 2009 UTC alarm 30464 occurred CFM MD 1 MA 1 MEP 2 all remote MEPs RDI defect disappear When CC message that sends from peer has RDI this alarm ap pears All series This alarm can be available from V4 8 23 30465 30465 6 Available Communication Alarm 5 Local can t receive CC message of peer This leads to protocol message to inform remote related event and local printing alarm Link fault check link state check configuration SomeRMEPCCMdefect MD d MA d MEP d s The first od is the ID of MD with DefRemoteCCM alarm The second d is the ID of MA with DefRemoteCCM alarm The third d is the ID of MEP with DefRemoteCCM alarm The first s is has not received CCM from some remote MEPs expired 3 5 times CCM s transmission interva when alarm appears the alarm is the content which shows above Some
174. id CCMs has been received when alarm appears the alarm is the content which shows above errorCCMdefect defect disappear when alarm disappears the alarm is the content which shows above Example 1 10 38 07 08 10 2009 UTC alarm 30466 occurred CFM MD 1 MA 1 MEP 2 one or more invalid CCMs has been received 36 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Description Supported Devices Appendix Specification Message No Default Security Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype Chapter 2 Alarm Message 2 10 38 10 08 10 2009 UTC alarm 30466 occurred CFM MD 1 MA 1 MEP 2 errorCCMdefect defect disappear When local receives faulty CC message that sends from peer this alarm appears All series This alarm can be available from V4 8 23 30467 30467 6 Available ConfigureErrorAlarm 5 Receive the CC messge which doesn t belong to this Level or doesn t belong to this MA Local prints alarm View local and remote configurations s MD d MA d MEP d s The first od is the ID of MD with RDI alarm The second d is the ID of MA with RDI alarm The third d is the ID of MEP with XCON alarm The first s is xconCCMdefect when alarm appears the alarm is the content which shows above When alarm disappears this character string is empty The second character string content
175. idential and Proprietary Information of ZTE CORPORATION 29 ZXR10 Alarm Handling Manual ZTEHX Cause For a certain interface board the quantity of local port returned from lower layer is O Recommended No Operations Software Alarm ETHOAM Alarm 16128 Message No 16128 Default Security 5 Level Alarm Type _ ProcessingErrorAlarm NM Level 5 Cause The local end starts loopback and the remote end fails to respond for the reason that the response is delayed or the status configu ration is not correct Influence Loopback fails Recommended Start loopback again Operations Alarm Description Interface s Prototype s is the reason The details are as follows 1 loopback failure for Mode Ethernet oam protocol mode can t satisfy loopback sending condition 2 Ethernet oam is not enable Ethernet oam is not enabled 3 Discovery is undone Ethernet oam protocol negotiation fails 4 in slave mode Local end ethernet oam is in slave mode 5 loopback has on off Local end ethernet oam is in on off mode 6 loopback respond start command failed Remote respond loopback start fails 7 loopback respond stop command failed 30 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype Alarm Description Supported Devices
176. ified by neighbor example OID 1 3 6 1 2 1 14 16 1 4 ospfConfigErrorType the possible types of OSPF configuration er rors as error version number mismatched area number and un known virtual neighbor OID 1 3 6 1 2 1 14 16 1 2 ospfPacketType OSPF packet type hello packet IsReq packet and IsAck packet OID 1 3 6 1 2 1 14 16 1 3 Confidential and Proprietary Information of ZTE CORPORATION 265 ZXR10 Alarm Handling Manual ZTEHX Information Description Triggering Criteria Recommended Operations Binding variables Information Description Triggering Criteria Recommended Operations Binding variables ospfVirtlfAuthFailure The authentication type or key of OSPF report received at vir tual interface is inconsistent with the relevant configuration of the router which causes the authentication failure 1 The authentication type or key of OSPF report received at OSPF virtual interface is inconsistent with the relevant configuration of the router 2 The SNMP configuration about OSPF trap sending is correct Please check whether the router configuration is consistent with the one about OSPF at the opposite end router ospfRouterld router ID used to distinguish the routers in au tonomous system and the value is only value OID 1 3 6 1 2 1 14 1 1 ospfVirtIfArealId the area ID crossed by OSPF virtual connection OID 1 3 6 1 2 1 14 9 1 1 ospfVirtIfNeighbor the router ID of OSPF virtual neig
177. iire ae eds emia EA eee ae 198 OT 198 AO A EE OE 198 DO a A T 198 28 OG iia dida 198 A a OOO 199 OA AS 199 DO A e ea vee uns 199 A O 199 LO iii A AA AA O ep 199 Phe o 200 DOI A A AA 200 IM A 200 RR icant iebistawed baaeaerd hivlamed E 200 O 200 O 201 UI to o 201 OOO iii A A A A 201 BOO iii ii A AO E estes 201 MI AEE E wie na eshte uae tee N 201 SOO it satiate foarte a ete talc a iar ti tial nats at ade da tial Sia 201 A ener sab a ed eee ee ae ee ees 202 SOD seco Wie eee eis awe eng ele aul ngewe econ avenge 202 E10 A Misia sane E E sae tea cue E eda N 202 A e 202 SODA s esec cave tais cent ecverciteaeveescvepenevecurpivdiedsecevevacvin evens 202 E10 Poe EEE AA 203 Oli A A A pee isis 203 A A 203 A AO 203 MO 203 AMOO Li A avant wed lagen es 203 FOO S ae skdieek uk Veseuste essed dans 204 A A A A 204 OO iii A A EA 204 ca 010 APPDDU o a 204 O ti vate te 204 BOOB reside sehen Manette hie edeateneinenewaden eterna stnds 204 4009 iu A A ar 205 O ee 205 O A E A O AO 205 O A 205 MO it RO A A 205 A E AN 206 Maa 206 O e Seach unas bees 206 AE AA Gorse Peraraahdotpenaenagsrarsidertenareegs teas duatenes ss 206 A E cs cerned veebv yds na dhevig ed eck TET 207 MOTA eis iinee tee decte eae a a De ceeds 207 4035 A A 207 AOS Giria tae helene con aaa Ont mn athe E tanta 207 a ONS TAE dip iaeee dvb dined A pits 207 A edit evens lenin eee eens eee 207 A O 208 A vce A A A O AN 208 OA ii A AR Ga 208 OA iii A aever reves teres 208 O
178. imum value This is the system prompt 4043 4043 The command is run in common user mode Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Chapter 3 Command Configuration Error Prompt Messages Please configure correct command 4044 4044 The coalition interface inputs cannot exceed 50 This is the system prompt 4045 4045 Alliance interface is configured Please remove it first Please remove alliance interface 4046 4046 Please configure the coalition ID first Please check whether the command configuration sequence is proper and whether the command configuration is correct 4047 4047 No local AS member is allowed existing in coalition node list Please check whether the command configuration is proper 4048 4048 No address family example Please check whether the command configuration is correct 4049 4049 Confidential and Proprietary Information of ZTE CORPORATION 209 ZXR10 Alarm Handling Manual Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message
179. in later 2032 2032 Fail to add import filter Check whether the command configuration is correct and try again later 2033 2033 Fail to add export filter Check whether the command configuration is correct and try again later 2034 2034 Fail to delete import filter Check whethewr the command configuration is correct and try again later 2035 2035 The imported template quantity reaches the maximum value 192 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Chapter 3 Command Configuration Error Prompt Messages None 2036 2036 The exported template quantity reaches the maximum value None 2037 2037 Fail to set area default cost Check whether the command configuration is correct and try again later 2038 2038 Fail to set area virtual connection parameter Check whether the command configuration is correct and try again later 2039 2039 Fail to reset LSA default interval timer It may try again later 2040 2040 Illegal LSA group time slice Please check whether the command parameter is correct and whether the parameter configuration is proper Confidential and Prop
180. ion Message No Default Severity Level ZTEDH There may be redundant configuration Please contact ZTE for the solution OAM Alarm 16899 16899 Available QoSAlarm 4 CPU load namely CPU utilization ratio reaches the set low thresh old It may bring to the slow operation response 16900 16901 If the operation with great consumption on cpu is carried out in short time then it is normal phenomenon Commands show process show process detail can be used to view CPU utilization s M panel d current CPU load is d s S panel d current CPU load is d The first s is the CPU type The first d is panel number and the second d is CPU utilization Alarm occured An alarm 16899 level 5 occurred at 00 52 07 01 01 2001 UTC sent by UPC MPU 1 OAM CPU load exceeds the lowest threshold NP M panel 7 current CPU load is 80 Alarm cleared An alarm 16899 level 5 cleared at 00 53 07 01 01 2001 UTC sent by UPC MPU 1 OAM CPU load exceeds the lowest threshold NP M panel 7 current CPU load is 50 CPU load namely CPU utilization ratio exceeds the set low thresh old All The platform 4 6 03b and the upgrade versions support this alarm Not CE amp PTN version 16900 16900 5 44 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Recovery Alarm Type NM Level Cause Influence Related Alarms Recommended Operations Alarm Prototype Description Alarm Des
181. ion data is abnormal Check the fiber connection between ONU module and OLT module This alarm is called bit error rate alarm in EPON project This alarm can be opened and closed by using command and set alarm switch alarm monitor direction and alarm threshold In default this alarm is enabled and the monitor direction is up down link the value is 10 unit 10 9 If the alarm need to be closed configure alarm bit error rate disable on OLT interface If the monitor direction and threshold need to be modified configure the command alarm bit error rate direction lt direction gt tthrressholld lt thresho ld gt on the OLT interface Epon alarm bit error rate occour at d in s direction dindicate bit error rate value when alarm occurs sindicate the monitor direction when bit error rate alarm occurs The monitor directions are as follows uplinkindicate monitor directiononly monitor the uplink communi cation data forwarded from ONU to OLT downlinkindicate monitor directiononly monitor the downlink com munication data forwarded from ONU to OLT up down link indicate monitor direction monitor the uplink and downlink communication data forwarded from ONU to OLT Example 18 57 30 08 26 2008 UTC alarm 33280 occurred EPON Epon alarm bit error rate occour at 100000 in uplink direction sent by NPC 3 Bit error occurs in communication between ONU module and OLT module EPON project of 4822 33281 33281 5 Comm
182. ion state before this alarm The third s the current session state The first d the reason that this alarm generates 00 01 07 01 01 2001 UTC alarm 25347 occurred LDP neigh bor 2 2 2 22 0 is down pre state OPERATIONAL state NONEX ISTENT status code 9 00 01 12 01 01 2001 UTC alarm 25347 cleared LDP neigh bor 2 2 2 22 0 is up pre state OPENREC state OPERA TIONAL status code 513 LDP neighbor turns from OPERATIONAL state to NON EXIST state ZXR10 T128 25349 25349 8 LDP GR is enabled 112 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Prototype Description Message No Default Severity Level Cause Alarm Prototype Description Message No Default Severity Level Cause Alarm Prototype Description Message No Default Severity Level Cause Alarm Prototype Description Message No Default Severity Level Cause Alarm Prototype Description Chapter 2 Alarm Message Alarm occurred 00 01 07 01 01 2001 UTC alarm 25349 occurred LDP GR 25351 25351 8 LDP protocol conducts the operation Clear MPLS LDP Neighbor Alarm occurred 00 01 07 01 01 2001 UTC alarm 25351 occurred LDP Clear neighbor 25354 25354 8 LDP protocol fails to operate memory including application for memory space release of memory and other operations Alarm occurred 00 01 07 01 01 2001 UTC alarm 25354 occurred LDP Mem ory 25355 25355 8 LDP p
183. iption Chapter 2 Alarm Message Alarm Occurred Fan errorreason s Alarm Recovered Fan recover s s cause The 3 types of new rack alarms are as follows only for new rack The fan data line isn t plugged into the BIC board If none of the 3 power modules are working it implies that the power and the fan are not plugged well 14 51 08 08 14 2008 UTC alarm 80 occurred Fan error reason The fan data line isn t plugged into the bic board sent by UPC MPU 1 Current Trunk Top Fan fail to work 14 44 38 08 14 2008 UTC alarm 80 occurred Fan er ror reason Current Trunk Top Fan fail to work sent by UPC MPU 1 Current Trunk Bottom Fan fail to work 15 51 32 08 14 2008 UTC alarm 80 occurred Fan error reason Current Trunk Bottom Fan fail to work sent by UPC MPU 1 The 4 types of old rack alarms are as follows only for old rack The fan data line isn t plugged into the BIC board If all the fans are not working it implies that the line of the fan is not plugged well 14 51 08 08 14 2008 UTC alarm 80 occurred Fan error reason The fan data line isn t plugged into the bic board sent by UPC MPU 1 Current Trunk Top Fan Num fail to work One or two of the 8 fans work abnormally The abnormal fan number is behind Num For example Num 3 5 14 53 08 08 14 2008 UTC alarm 80 occurred Fan error reason Current Trunk Top Fan Num 3 4 7 8 fail to work sent by UPC MPU 1 Current Trunk Bottom Fan Num fail to
184. is one or more cross connect CCMs has been received when alarm appears the alarm is the content which shows above xconCCMdefect defect disappear when alarm disappears the alarm is the content which shows above Example 1 10 38 07 08 10 2009 UTC alarm 30467 occurred CFM MD 1 MA 1 MEP 2 one or more cross connect CCMs has been re ceived 2 10 38 10 08 10 2009 UTC alarm 30467 occurred CFM MD 1 MA 1 MEP 2 xconCCMdefect defect disappear Confidential and Proprietary Information of ZTE CORPORATION 37 ZXR10 Alarm Handling Manual Alarm Description Supported Devices Appendix Specification Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Alarm Prototype Description Message No Default Severity Level Alarm Recovery Alarm Type NM Level ZTEDH When the CC messge which doesn t belong to this Level or this MA is received this alarm appears All series This alarm can be available from V4 8 23 ROS Alarm 16384 16384 The process is suspended Please copy and save the information then contact ZTE mainte nance staff 16386 16386 Privileged mode password is changed Please check the password 16389 16389 6 The rack is cold starting which is opposite to hot starting Cold starting means that to turn on the power and start up the device Hot starting means th
185. is changed Please check whether the ARP item MAC address is legal if it is illegally changed bind correct MAC address manually to protect legal users from being attacked 19713 19713 6 It exceeds the item limitation based on interface overall pro tected by ARP Check whether ARP protection is configured and whether anybody attacks balefully to pour ARP table fully 19714 19714 6 The received ARP report source MAC address is the same as local MAC address 84 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Chapter 2 Alarm Message Check whether the MAC address is legal 19715 19715 6 The received ARP source IP address is conflict with local interface address Check whether the IP address is legal and whether two sets of equipments have the same IP address 19716 19716 6 Enable ARP inspection for DHCP Snooping function If source ad dress of the received ARP packet is an illegal DHCP user then drop it Please check whether ARP inspection is enabled for DHCP Snooping function 19717 19717 6 IP POOL filtering function is enabled
186. isabled This is the system prompt Check whether the shutdown of this interface influences other protocols or procesure 9106 9106 The pim spare mode is configured This is the system prompt 9201 9201 The pimsm is running on this interface 244 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages This is the system prompt 9202 9202 The pimsm is not started on this interface This is the system prompt 9203 9203 The spt threshold does not exist Please check whether the command configuration is proper and correct 9204 9204 The pim dense mode is configured This is the system prompt 9501 9501 There are few interfaces in the channel group Please check whether the system configuration is correct and proper 9502 9502 Error parameter type Confidential and Proprietary Information of ZTE CORPORATION 245 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Ca
187. it non null 30206 30206 At ESM_UDF mode user configured entry number occupied ESM space has exceeded space of Sram or TCAM TCAM space 350MHz 521K 500MHz 256K Confidential and Proprietary Information of ZTE CORPORATION 255 ZXR10 Alarm Handling Manual ZTEHX Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Clear or modify a entry size first to limit entry size in the specific space 30207 30207 TCAM with work frequency 350MHz doesn t support configuration of these entries Note TCAM type when it is configured 30208 30208 The deleting ACL mode of ESM configuration does not exist Configure ESM acl mode first and then delete 256 Confidential and Proprietary Information of ZTE CORPORATION Information Description Triggering Criteria Recommended Operations Chapter 4 TRAP Messages Table of Contents TRAP Message EXDISnaIO n d pais 257 SYSIETY TRAF MESSIDE sanoen nia domcnniaueveccsisiedesceteimeees 257 Alarm TRAP Message ii 259 RMON TRAP MESS OE vespa ADN 261 OSPF TRAP Message xro ai IAEA AAA AA SRA NADA IRA E 262 BOF TRAP Message sins iba bl ie bb aio 271 Br TRAF Mes is a 272 REP TRAP MOSSIE errar 273 IPYGTRAP INM MA ici ear Rea AR Eai 274 POE TRAP Into mac ari a da 274 TRAP Message Explanation In the SNMP NMS trap indicates a type of alarm report similar to syslog report Every trap has
188. k whether the system is busy or the system flash exists or is damaged please If fail to retry many times please contact ZTE maintenance staff after recording the error Confidential and Proprietary Information of ZTE CORPORATION 153 ZXR10 Alarm Handling Manual Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH 100 100 Fail to send message to Idp process Please check whether the system is running normally and retry when the system is idle 101 101 Fail to extract interface from mpls table Please check whether the input parameter is correct and try again later 102 102 It does not configure enable mpls command Please execute enable mpls command first 103 103 The command takes effect at the next start N A 104 104 router id cannot be 0 Please configure correct command 105 105 Too many Idp interfaces 154 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Chapter 3
189. larm Prototype Description Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Related Alarms Recommended Operations Alarm Prototype Description Alarm Description Supported Devices ZTEDH example maximum routes 100 75 to increase the routing maxi mum threshold the first parameter The routes limit of s is exceeded s is the vpn name that generates the alarm An alarm 18195 level 6 occurred at 00 01 37 01 01 2001 UTC sent by MCP DRP The routes limit of VPN1 is exceeded The entering vrf routing exceeds the configured maximum thresh old T128 69 N A 18196 18196 6 Unavailable QoSAlarm 5 The VPN Route Limit function is set For example in vrf config ure mode configure maximum routes 4 75 or maximum routes 4 warning only When a new routing is added to vrf the current route items including the new routing reaches the upper limit of the maximum when configuring maximum routes 4 75 the alarm threshold is 4 75 3 when configuring maximum routes 4 warning only the alarm threshold is 4 100 4 then the alarm occurs 18195 Increase the routing maximum threshold according to the circum stance Reduce the alarm Configure Vpn route limit fuction man ner one magnify the alarm threshold the second parameter For example use maximum routes 100 95 instead of maximum routes 100 75 Manner t
190. les Information Description Triggering Criteria Recommended Operations Binding variables Information Description Triggering Criteria Recommended Operations ZTEDH 1 BGP state machine status is changed from high level status to lower level status 2 The SNMP configuration about BGP trap sending is correct Please check if the routers at both peer sides are running normally the link connection status is normal and if it is caused by improper router protocol configuration modification bgpPeerLastError error number and sub number appeared on BGP peer value 0 if no error OID 1 3 6 1 2 1 15 3 1 14 bgpPeerState BGP peer status as idle connect and active O1ID 1 3 6 1 2 1 15 3 1 2 DHCP TRAP Message online The trap message sent when DHCP user gets online 1 DHCP user gets online 2 SNMP configuration for sending trap is correct No No offline The trap message sent when DHCP user gets Offline 1 DHCP user gets offline 2 SNMP configuration for sending trap is correct No 272 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Binding variables Information Description Triggering Criteria Recommended Operations Binding variables Information Description Triggering Criteria Recommended Operations Binding variables Chapter 4 TRAP Messages No VRRP TRAP Message vrrp TrapAuthFailure Vrrp authentication is failure
191. lly 7051 7051 Timer error occurs when starting log file timing Please try again later 7052 7052 Timer error occurs when starting log timing saving Please try again later 7053 7053 Error pointers to obtain the message return area Confidential and Proprietary Information of ZTE CORPORATION 225 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No ZTEDH Please try again later 7061 7061 Error alarm ID Please check whether the input parameter is correct 7062 7062 Error level corresponding to alarm ID Please check whether the input parameter is correct 7063 7063 Error alarm type Please check whether the input parameter is correct 7064 7064 Error occurs when searching alarm operations Please try again later 7065 7065 The alarm level corresponding to the alarm ID cannot be changed as the specific value Please check whether the input parameter is correct 7066 7066 226 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended
192. ly Check whether the TCP connection and network status are normal 18460 18460 3 TCP fails in clearing nonexistent connections Check whether the TCP connection is normal 18461 18461 4 TCP calculates the available windows incorrectly Check whether the TCP connection is normal 18463 18463 4 When received BGP message MD5 authentication fails 74 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Chapter 2 Alarm Message Check Whether the passwords in two ends of BGP are the same 18464 18464 4 PROTOCOL fails to send message to application procedure Check Whether the passwords in two ends of BGP are the same UDP Alarm 18560 18560 4 UDP MP Initialization creates synchronous timer incorrectly Restart UDP 18561 18561 3 UDP module fails to apply for memory Check whether the system is running normally If necessary save the configuration and then restart the router 18562 18562 7 UDP receives the packets with wrong headers Check whether the network connection and router running is nor mal 18563 18563
193. m 2 port alarm 3 OID 1 3 6 1 4 1 3902 3 4 6 1 9 Alarm variable value O as no OID 1 3 6 1 4 1 3902 3 4 6 1 10 Alarm upper variable value O as no OID 1 3 6 1 4 1 3902 3 4 6 1 11 Alarm lower variable value O as no OID 1 3 6 1 4 1 3902 3 4 6 1 12 Alarm description message OID 1 3 6 1 4 1 3902 3 4 6 1 13 Software Alarm Trap The trap is sent when a software alarm occurs on equipment 1 A software alarm occurs on equipment 2 It configures unm on and unm server commands 3 The relevant configuration for SNMP sending trap is correct Please find the corresponding operation recommendation accord ing to the alarm code bound in the alarm trap Rack No value 1 OID 1 3 6 1 4 1 3902 3 4 7 1 1 Shelf No value 1 OID 1 3 6 1 4 1 3902 3 4 7 1 2 Slot number OID 1 3 6 1 4 1 3902 3 4 7 1 3 Alarm Code OID 1 3 6 1 4 1 3902 3 4 7 1 4 Alarm Severe level OID 1 3 6 1 4 1 3902 3 4 7 1 5 Alarm generation time OID 1 3 6 1 4 1 3902 3 4 7 1 6 Alarm status alarm created OID 1 3 6 1 4 1 3902 3 4 7 1 7 Alarm Type ros 65 database 66 260 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Syntax Information Description Triggering Criteria Recommended Operations Binding variables Information Description Triggering Criteria Recommended Operations Binding variables Chapter 4 TRAP Messages OID 1 3 6 1 4 1 3902 3 4 7 1 8 Alarm description message OID 1 3 6 1 4 1 3902 3 4
194. m the software or the hardware 2 The general disposal methods for the alarms are as follows i For hardware or device malfunction contact with ZTE ser vice staff to replace it For malfunctions such as hardware dissatisfactory add the hardware or replace the low ca pacity parts ii For software or the system malfunctions upgrade or down grade the software version Backup the configuration be fore version upgrading For alarms caused by the environment please check and resolve the problems in time according to alarm failure and alarm message Avoide or reduce the direct or physical damage for the device caused by the environment iv For system setup and configuration problems check where the malfunction is and modify the configuration For alarms caused by error input commands please view the online command help or refer to related manual and execute it after inputting this command again v For alarms caused by the other end inform the other end of the displayed alarm message and assist in resolving this problem And then check and inform the other end whether this alarm is removed 3 For alarms that can not be resolved by users contact with ZXR10 router professors of ZTE corporation or call our cus 4 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Chapter 1 Alarm Overview tomer support center at 800 830 1118 for free 400 830 1118 modename for free and 0711 65000 military netwo
195. mation of ZTE CORPORATION 103 ZXR10 Alarm Handling Manual Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Prototype Description ZTEDH T64E T128 T600 T1200 series router 23815 23815 6 Unavailable ProcessingErrorAlarm 5 DHCP Relay Server address is the local VRRP address in the L3 interface that the DHCP users access Check whether the DHCP Relay Server address is the local VRRP address in DHCP Relay layer 3 interface If it is the local VRRP address then configure the DHCP Relay server again relay server s is local vrrp addr s IP address of DHCP Relay Server Alarm occurred 11 17 08 07 17 2008 UTC alarm 23815 occurred DHCP relay server 100 1 1 3 is local vrrp addr sent by NPC2 DHCP Relay Server address is the local VRRP address in the L3 interface that the DHCP users access ZXR10 3900 5900 6900 series switch T64E T128 T600 T1200 series router 23816 23816 6 Unavailable ProcessingErrorAlarm 5 DHCP Relay Server address is the local address in the L3 interface that the DHCP users access The user in L3 interface can not obtain the IP address Check whether the DHCP Relay Server address is the local address in DHCP R
196. mber of MAC addresses is lower than the threshold set by VLAN 59A69 89 22795 22795 6 None EquipmentAlarm 5 The MAC event number reaches the maximum value The MAC event number reaches the maximum value need apply for room None MAC event number threshold reached The MAC event number reaches the maximum value None This alarm is not supported by any of version at present 22796 22796 6 None EquipmentAlarm 5 When the interface is bound with smartgroup if physical interface configures permanent mac alarm need to promprt that permanent mac address should be deleted prompt permanent MAC deletion None lt Port s gt Permanent MAC address canceled When the interface is bound with smartgroup if physical interface configures permanent mac alarm need to promprt that permanent mac address should be deleted None 98 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Appendix Specification Message No Default Security Level Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level Cause Influence Alarm Description Prototype Alarm Description Supported Devices Chapter 2 Alarm Message This alarm is not supported by any of version at present 22797 22797 6 EquipmentAlarm 5 MAC learning mode is set
197. mended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages 9004 5004 Fail in connection and shut down the telnet Please try again later 9005 5005 The memory cannot be distributed and there is no way to start TCP connection Please try again later 9006 5006 TCP connection does not exist or cannot be cleared Please try again later 9007 5007 The ip vrf routing table does not exist Please check if the command configuration and parameter are cor rect 6001 6001 Error RMON group number Please confirm whether the current version supports RMON related groups and the command configuration is correct 6010 6010 Error data in received message packet Confidential and Proprietary Information of ZTE CORPORATION 213 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations ZTEDH Please try again later 6011 6011 Error header of received packet Please try again later 6012 6012 The received internal message return area is blank Please try again later 6020 6020 Error ID of received message Pl
198. message Please configure correct command 8009 8009 The buffer is insufficient Please try again later 8010 8010 Error occurs when obtaining configuration information Please try again later 8011 8011 228 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Chapter 3 Command Configuration Error Prompt Messages Error occurs when creating encrypted key Please try again later 8501 8501 Error authentication protocol type Please check whether the command configuration is correct 8502 8502 The host name is too long Please check whether the input parameter is proper 8503 8503 The password character string is too long Please check whether the input parameter is proper 8504 8504 Error board type Please check whether the input parameter is correct 8505 8505 PPP is not configured on this interface Please check whether the system configuration is correct 8506 8506 Confidential and Proprietary Information of ZTE CORPORATION 229 ZXR10 Alarm Handling Manual Cause Recommended Operations Message No Cause Recommended Operations Message No Cau
199. meter 264 264 The same ACL item exists Please verify or configure other ACL 265 265 It carries out a special command wait for a while please Try again later 266 266 The target file is not existed Please input the correct target file 267 267 The copies are wrong and fail to write file Check whether the system operation is normal and try again later If error remained many times please contact ZTE maintenance staff after recording the error Confidential and Proprietary Information of ZTE CORPORATION 167 ZXR10 Alarm Handling Manual Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH 268 268 Fail in the operation The target file is under use Please try again later 269 269 The new file name expression is wrong Please input the proper characters according to command param eter requirement 270 270 This command can only be run at the console serial port Please input the correct command 2 1 271 Fail in the operation The flash is under use Please try again later 272 272 Fail to access There are too many users online at present Please try again later 273 273 Fail to access There are too many users online at present 1
200. mmended Operations Message No NM Level Cause Recommended Operations Message No NM Level Cause Recommended Operations Alarm Prototype Description ZTEDH URPF Alarm 21248 21248 5 Source route check failure alarms N A ACL Alarm 21762 21762 5 There is wrong drive when binding ACL to the interface The reason is that much QoS is applied in ACL Reduce QoS application in ACL and bind again 21764 21764 5 There is wrong drive when binding ACL to the interface Check ACL QoS configuration and reduce QoS quantity and ACL rule number Try again 21773 21773 6 When Line card reboots one type of ACL ACL name for example ACL test is deleted N A Alarm occurred 05 46 35 04 16 2003 UTC alarm 21773 occurred IP SYNC ACLs NPC send message failedsent by MEC 1 92 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Alarm Type NM Level Cause Influence Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Alarm Type NM Level Cause Influence Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Severity Level Chapter 2 Alarm Message 21774 21774 ProcessingErrorAlarm 5 Because one securityaccess item is set to ON state Multiple secu rity access entries are in ON state on a non stack master device
201. n The rack can not work normally No 1 Reboot the two boards with abnormal alarm 2 If reboot operation is invalid contact with ZTE service staff 3 ZTE service staff can input printHardwareState in ros and record the result 2 s is s system abnormal The first s is the abnormal CPU type Generally it is SFC MPU or RPU The second s is the abnormal master or slave state The second s is the abnormal master or slave state 16 30 38 06 21 2007 UTC alarm 300 occurred 2 SFC is mas ter system abnormal sent by UPC MPU 2 16 38 39 06 21 2007 UTC alarm 300 cleared 2 SFC is master sys tem abnormal sent by UPC MPU 2 The double SFC MPU RPU are both active or both standby caused by hardware malfunction Confidential and Proprietary Information of ZTE CORPORATION 23 ZXR10 Alarm Handling Manual Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Related Alarms Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause ZTEDH T64 T1200 T600 T1200 N A 301 301 6 Unavailable Equipment Alarm 5 Abnormality of NPCT line card will lead to interruption of switch network reset which further causes the repeat reset of switch network and thus normal line card
202. nal notice No action is needed 206 206 Fail in Network to network copy 156 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages Please input the correct copy command 207 207 The command explanation module sends error messages Please check whether the system is running normally and try again later If error remained many times please contact ZTE mainte nance staff after recording the error 208 208 Transmit synchronization message incorrectly Please check whether the system is running normally and try again later If error remained many times please contact ZTE mainte nance staff after recording the error 209 209 Transmit asynchronization message incorrectly Please check whether the system is running normally and try again later If error remained many times please contact ZTE mainte nance staff after recording the error 210 210 Fail to delete directory Please check whether any file is still under the directory or any user under the current directory If no please try again 211 211 Succeed in copying file Confidential and Proprietary Information of ZTE CORPORAT
203. nce Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype ZTEDH 33291 33291 5 CommunicationAlarm 5 The total number of ONU that connects with OLT in downstream exceeds the specification that system supports EPON device can t run normally for overloading Limit the number of ONU connections under OLT to 32 This alarm is called onu over limitation alarm in EPON project In default this alarm is enabled If the alarm need to be disabled configure alarm onu over limitation disable on OLT interface Epon alarm onu over limitation occour Example 14 57 30 08 26 2008 UTC alarm 33291 occurred EPON Epon alarm onu over limitation occour sent by NPC 3 The number of ONU devices connected to OLT in downstream ex ceeds 32 EPON project of 4822 33292 33292 5 CommunicationAlarm 4 Optical power in upstream that OLT receives from a ONU is too low lower than OLT sensitivity upper limit or too high higher than OLT overload optical power lower limit The optical path is abnormal Test optical power Epon alarm optical power overflow occour Epon alarm optical power overflow recover Example 10 57 30 08 26 2008 UTC alarm 33292 occurred EPON Epon alarm optical power overflow occour sent by NPC 3 Alarm reco
204. nd cannot delete the e1 channelized interface Refer to the related manuals and use this command in the right interface 284 284 The command cannot delete the interface specified in command Check whether the interface parameter in the command configu ration is correct and whether the interface attribute can be deleted by this command 285 285 The configured route map items reach to the limitation Check the configured route map items and delete some unneces sary items then perform configuration 288 288 Too many configured prefix list items it reaches to permitted item quantity limitation Check the configured prefix list items and delete some unneces sary items then perform the configuration 170 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages 289 289 Fail to write prefix list to database Check whether the configured prefix list items reaches to limita tion if not try again later If it remains the same after retrying many times please contact ZTE maintenance staff after recording the error 290 290 Fail to find prefix list item Check whether the prefix list in configuration parameter exis
205. nfiguration All series This alarm can be available from V4 8 22 16131 16131 5 CommunicationAlarm 5 The local receives the related fault event such as link fault dying gasp fault and fault frame event Generate protocol message to inform remote related event and print alarm locally Check attribute configuration and re initiate Ethernet OAM proto col negotiation Discovery s localmac s peermac s The first s details are as follows Link fault check link state Dying gasp fault check device state Critical fault check device state Error frame event check received error frames ead ae 32 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Description Chapter 2 Alarm Message Interface s localmac s peermac s The first s details are as follows 1 occur remote link fault occur remote link fault event occur remote dying gasp event occur remote dying gasp event occur remote critical event occur remote critical event occur local link fault occur local link fault occur local dying gasp event occur local dying gasp event occur local critical event occur local critical event i occur error frame event occur error frame event locally ii occur error frame period event occur error frame period event locally iii occur error frame second event occur error frame second event locally iv occur error symbol period event occur error symbol period event locally T
206. nkindicate monitor directiononly monitor the uplink communi cation data forwarded from ONU to OLT downlinkindicate monitor directiononly monitor the downlink com munication data forwarded from ONU to OLT up down link indicate monitor direction monitor the uplink and downlink communication data forwarded from ONU to OLT Example 18 57 30 08 26 2008 UTC alarm 33281 occurred EPON Epon alarm frame error rate occour at 1000 in up down link direction sent by NPC 3 Frame error occurs in communication between ONU module and OLT module EPON project of 4822 33282 33282 5 CommunicationAlarm 5 Time slot is wrong and ONU module doesn t forward packets in its own time slot ONU forwards data abnormally Check time slot on ONU module This alarm is called llid mismatch alarm in EPON project In de fault this alarm is disabled and LLID matching fault frame thresh old is 5000 frames If the alarm need to be enabled configure alarm llid mismatch enable on OLT interface If the alarm thresh old need to be modified configure the command alarm Ilid mism atch threshold lt threshold gt on the OLT interface Epon alarm llid mismatch occour at d dindicate llid mismatch value when alarm occurs Example 136 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level Cause Influence Recommended
207. nnumber attribution of interface first 1049 1049 The input PVC value reaches the maximum limit Please check whether the system configuration is proper and the configuration information reaches the maximum system permitted value 180 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Chapter 3 Command Configuration Error Prompt Messages 1050 1050 The acl list does not exist Please check whether the parameter acl list is correct and whether the command configuration sequence is proper 1051 1051 Only PVC is allowed on point to point network This is the system prompt 1052 1052 PVC does not exist Please check whether the input parameter is correct and the com mand configuration sequence is proper 1053 1053 Fail to create ATM interface Please check whether the system configuration reaches the maxi mum value if not please try again later 1054 1054 Fail to delete ATM interface Please check whether the input parameter is correct and try again later 1055 1055 Confidential and Proprietary Information of ZTE CORPORATION 181 ZXR10 Alarm Handling Manual Cause Recommended Operations Message
208. normal and try again later if normal 148 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Chapter 3 Command Configuration Error Prompt Messages 18 18 nvram overflowed None 19 19 flash overflowed Please delete some useless files in the flash first 20 20 Fail to write nvram Check whether the system operation is normal and try again later If unsuccessful please contact ZTE maintenance staff after record ing the error 21 21 Fail to write to flash Check whether the system operation is normal then try again when the system is idle 22 22 Fail to read nvram Check whether the system operation is normal and whether nvram is damaged If everything is normal try again later please If the prompt remained please contact ZTE maintenance staff after recording the error Confidential and Proprietary Information of ZTE CORPORATION 149 ZXR10 Alarm Handling Manual Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH 23 23 Fail to read flash Please check
209. o Default Severity Level Cause Alarm ProtoType Description Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Chapter 2 Alarm Message 8 L2VPN VC resources are insufficient Alarm occurred 00 01 07 01 01 2001 UTC alarm 25858 occurred L2VPN GR 25863 25863 8 It fails to operate L2VPN timer Alarm occurred 00 01 07 01 01 2001 UTC alarm 25863 occurred Timer LZVPN 25864 25864 8 L2VPN LABEL resources are insufficient Alarm occurred 00 01 07 01 01 2001 UTC alarm 25864 occurred L2VPN Label ZESR Alarms 26368 26368 6 ZESR ring turns from down state to up state It notifies state changes of ZESR master node 26369 26369 6 ZESR ring turns from down state to preup state Confidential and Proprietary Information of ZTE CORPORATION 115 ZXR10 Alarm Handling Manual Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause ZTEDH It notifies state changes of ZESR master node 26370 26370 6 ZESR ring turns from up state to down state and the reason is that Hello packet times out It n
210. o view the utilization ratio that process uses CPU resource Task s current CPU load is d 02d exceeds the lowest Threshold d The first s is process name type The first d and second d are peak value of utilization ratio that process uses CPU resource The third d is low threshold that process uses CPU resource Confidential and Proprietary Information of ZTE CORPORATION 51 ZXR10 Alarm Handling Manual Alarm Description Supported Devices Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations ZTEDH Alarm Generated An alarm 16924 level 5 occurred at 00 56 07 01 01 2001 UTC sent by UPC MPU 1 OAM Task ACL current CPU load is 20 0 exceeds the lowest Threshold 15 Alarm Recovery An alarm 16924 level 5 cleared at 00 57 07 01 01 2001 UTC sent by UPC MPU 1 OAM Task ACL current CPU load is 10 0 under the lowest Threshold 15 The utilization ratio that process uses CPU resource reaches de fined low threshold 6989 OSPF Alarm 17408 17408 6 The port status shifts Check whether OSPF status shift is normal according to the dis played alarm message Ifitis abnormal please check whether the configuration is correct and the corresponding status is correct 17409 17409 6 The virtual link port status shifts Check
211. ol packet Please check whether the network condition is correct suitable If there is no problem of the configuration please copy the info and contact ZTE s maintenance personnel Alarm occured 10 55 05 03 29 2007 UTC alarm 22793 occurred MAC lt MAC Table gt mode in micode learning please input mac learn special sent by MEC 1 The original alarm message number is 21768 ZESS Alarm 32512 32512 6 Available Equipment Alarm 4 ZESS link state turns from UP to DOWN N A Domain u from down to up Domain u from up to down d the area id number it can be 1 4 An alarm 32512 level 5 occurred at 04 49 42 02 01 2001 UTC sent by NPC 2 ZESS Domain 1 from down to up 130 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Chapter 2 Alarm Message An alarm 32512 level 5 cleared at 04 49 42 02 01 2001 UTC sent by NPC 2 ZESS Domain 1 from up to down ZESS link state is DOWN ZXR10 T40 T64 T160 N A 32513 32513 6 Unavailable
212. olicy first 4034 4034 The interface does not exist Please check whether the input parameter is correct 4035 4035 This policy does not exist or cannot be deleted Please check whether the input parameter is correct and try again later 4036 4036 It supports maximum 3 neighbors debug function at one time This is the system prompt 4037 4037 The neighbor s update debug function is not enabled This is the system prompt 4038 4038 Confidential and Proprietary Information of ZTE CORPORATION 207 ZXR10 Alarm Handling Manual Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause 208 ZTEDH Reflect can be configured only at the internal end point This is the system prompt 4039 4039 It cannot configure local system as a neighbor Please check whether the command configuration is correct 4040 4040 It cannot delete private AS from IBGP end point Please check whether the command configuration is proper and correct 4041 4041 The neighbor is configured as RR client Please delete the attribu tion first Check whether the command configuration sequence is proper and the command configuration is correct 4042 4042 The coalition end point quantity exceeds the max
213. on SUPERVLAN interface If the source address of received ARP packet is not in IP POOL seg ment then drop it Please check whether IP POOL filtering function is enabled on SU PERVLAN interface and check IP pool configuration information If filtering is not needed here please disable this function 19720 19720 5 Unvailable Environmental Alarm 3 Specify that at most 100 ARP packets can be received on interface per second If the received packets are more than 100 drop the Confidential and Proprietary Information of ZTE CORPORATION 85 ZXR10 Alarm Handling Manual Influence Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause ZTEDH superfluous packets and interface is believed under ARP attack Meanwhile alarm appears Operation response may be slow Reduce system load Arp Flood 03 16 51 01 18 2001 UTC alarm 19720 occurred ARP Arp Flood on fei_1 1 sent by MCP Interface is under ARP attack and received ARP packets are more than 100 GAR18 28 38 The platform V2 8 01b and the upgrade versions support this alarm IS IS Alarm 19968 19968 6 Neighbors set up the adjacent relationship N A 19969 19969 6 The neighb
214. on fails Check whether the set authentication password of adjacent equip ment at the virtual interface corresponding to home equipment is consistent with the configuration on home equipment 17414 17414 6 The port receives error packets Check whether the physical interface connection is reliable 17415 17415 Confidential and Proprietary Information of ZTE CORPORATION 53 ZXR10 Alarm Handling Manual Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations ZTEDH 6 The virtual port receives error packets Check whether the physical connection of interfaces forming the virtual interface is reliable 17416 17416 6 The database size is beyond the threshold After saving configuration information re enable relative module or restart equipment if possible 17417 17417 6 The interface configuration is wrong Modify the interface configuration to be inconsistent with the op posite end interface 17418 17418 6 The virtual interface configuration is wrong Modify the virtual interface configuration inconsistent with the op posite end interface 17419 17419 7 Packets are retransmi
215. on is normal and the sys tem resource occupancy is in normal range 17958 17958 6 Fail to distribute memory Check whether the route quantity is to maximum and system memory application is to the maximum value 17959 17959 6 Fail to insert route Check whether the route quantity is to maximum and system memory application is to the maximum value 17960 17960 6 Distribution protocol fails to use route memory Check whether the route quantity is to maximum and system memory application is to the maximum value 17961 17961 6 The status shifts Confidential and Proprietary Information of ZTE CORPORATION 65 ZXR10 Alarm Handling Manual Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Syntax Message No Default Severity Level Cause Recommended Operations Message No ZTEDH Check whether the status shift is normal according to the descrip tion in alarm messages If it is abnormal please check whether the system is running normally the configuration is correct the port and the opposite end are running normally 17962 17962 6 Fail to obtain index number when establishing neighbors Please check whether the BGP configuration is correct 17963 17963 6 The neigh
216. onfidential and Proprietary Information of ZTE CORPORATION 13 ZXR10 Alarm Handling Manual Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Related Alarms Recommended Operations Alarm Prototype Description ZTEDH The first s is the board type the first d is the panel number of the board the second d is the centigrade temperature of the board the third d is the Fahrenheit temperature of board the fourth d is the centigrade temperature of the set threshold and the fifth d is the Fahrenheit temperature of the set threshold Alarm Occurred s Current remote temperature is d C dF under the low threshold d C dF Alarm Cleared s Current remote temperature is d C dF exceeds the low threshold d C dF The first s is the board type and is fixed to BIC board There is no panel number on BIC board so the display format is different from other board the first d is the centigrade temperature of the board the second d is the Fahrenheit temperature of board the third d is the centigrade temperature of the set threshold and the fourth d is the Fahrenheit temperature of the set threshold An alarm 67 level 5 occurred at 02 01 20 01 28 2001 UTC sent by UPC MPU 2 ENVIRONMENT SFC Panel 1 Current remote temperature is 51 C 123F under the low threshold 56 C 132F An alarm 67 level 5 cleared at 02 01 30
217. or is invalid Check whether the system operation and network connection is normal and whether the configuration is correct 19970 19970 5 Receive LSP packet from an invalid neighbor 86 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Chapter 2 Alarm Message Check whether the system configuration is correct 19972 19972 6 Receive LSP packet from an unknown neighbor Check whether the system configuration is correct 19974 19974 6 Neighbor fails in authentication Check whether the system configuration is correct and whether it is consistent with the configuration of the opposite end 19975 19975 6 LSP packet fails in authentication Check whether the system configuration is correct and whether it is consistent with the configuration of the opposite end 19976 19976 6 SNP packet fails in authentication Check whether the system configuration is correct and whether it is consistent with the configuration of the opposite end 19977 19977 6 Receive illegal packets Confidential and Propri
218. orm of E1 interface first This is the system prompt 8706 8706 Please exit the diagnosis mode first Please exit the diagnosis mode and then input the command 8707 8707 Please exit the multi linkset configuration mode first Please exit the multi linkset configuration mode and then input the command 8708 8708 The command is illegal Please check whether the command is supported in the mode 8801 8801 vrf does not exist Confidential and Proprietary Information of ZTE CORPORATION 237 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH Please check whether the command configuration is correct 8802 8802 The command no ip vrf is not executed Please run no ip vrf command before configuring vrf 8803 8803 RD cannot be set Please confirm the value is unique Please confirm RD value is unique 8804 8804 VRF is being deleted Please try again later 8805 8805 VRF has no RD or is being deleted Please try again later 8806 8806 VRF does not exist or it has no RD Please check whether the command configuration is correct 8901 8901 No frame relay example at the interface 238 Confidenti
219. otifies state changes of ZESR master node 26371 26371 6 ZESR ring turns from up state to down state and the reason is that Link down frame is received It notifies state changes of ZESR master node 26372 26372 6 ZESR ring turns from preup state to down state and the reason is that Hello packet times out It notifies state changes of ZESR master node 26373 26373 6 ZESR ring turns from preup state to down state and the reason is that Link down frame is received It notifies state changes of ZESR master node 26374 26374 6 ZESR ring turns from preup state to up state 116 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Chapter 2 Alarm Message It notifies state changes of ZESR master node 26375 26375 6 ZESR ring turns from down state to up state It notifies state changes of ZESR master node 26376 26376 6 ZESR ring turns from up state to down state It notifies state changes of ZESR master node TACACS Alarms 28160 28160 5 Tacacs client authentication queue is full Please check whether the configuration of tacacs server
220. ply exceeds power threshold Check if the temperature of environment where switch is in is too high Disable POE function because that the whole PSE is over temper ature on the switch Disable poe function of the pse d because of over temperature on the switch Example 09 40 10 11 13 2008 UTC alarm 30721 occurred POE Dis able poe function of the pse 1 because of over temperature on the switch sent by MEC 1 PSE total power of the power supply exceeds power threshold or recovers in the range of power threshold The usage power dw is below the PSE threshold dw on pse O Yo The first d PSE total power of the power supply The second d PSE power threshold The third d PSE device number The usage power dw is above the PSE threshold dw on pse The first d PSE total power of the power supply The second d PSE power threshold The third d PSE device number Example 132 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Description Supported Devices Message No Default Security Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype Alarm Description Chapter 2 Alarm Message 19 38 23 06 19 2006 UTC alarm 30720 occurred POE The us age power Ow is below the PSE threshold 30w on pse 1 sent by MCP 1 PSE disables POE function because of over temperature on the switch 2 PSE total
221. pplication Confidential and Proprietary Information of ZTE CORPORATION 125 ZXR10 Alarm Handling Manual ZTEHX Alarm Description Supported Devices Message No Default Severity Level Cause Recommended Operations Alarm Prototype Description Message No Default Severity Level Cause Recommended Operations Alarm Prototype Description 00 02 16 02 08 2002 UTC alarm 30208 occurred BFD Session 10 40 64 120 gt 10 40 64 121 is CONNECT on interface fei_1 1 When the system restore the relative sub event to the event list the event total number already reaches the upper threshold G series ZXR10 6900 8900 30209 30209 5 BFD session is established and the state machine changes to UP It is a prompt There is no need to care about it BFD application prompt for LDP LSP 00 02 16 02 08 2002 UTC alarm 30209 occurred BFD Session LDP BFD For FEC 10 40 64 121 is UP on interface fei_1 1 BFD application prompt for RSVP LSP 00 02 16 02 08 2002 UTC alarm 30208 occurred BFD Session RSVP BFD For tunneli is UP on interface fei_1 1 The prompt for other application 00 02 16 02 08 2002 UTC alarm 30208 occurred BFD Session 10 40 64 120 gt 10 40 64 121 is UP on interface fei_1 1 30210 30210 5 BFD session is established and the state machine changes to DOWN It is a prompt There is no need to care about it BFD application prompt for LDP LSP 00 02 16 02 08 2002 UTC alarm 3020
222. r The second s The string BROADCAST or P2P The third s The string P2P or BROADCAST Port s port num d is deleted s interface name d interface number Port s port num d is not found delete it s interface name Confidential and Proprietary Information of ZTE CORPORATION 89 ZXR10 Alarm Handling Manual Supported Device Message No NM Level Cause Recommended Operations Message No NM Level Cause Recommended Operations Message No NM Level Cause Recommended Operations Message No NM Level ZTEDH d Port s port num d remove from instance d s interface number interface number The first d interface number The second d ISIS instance number from 1 to 10000 17 13 47 06 25 2008 UTC alarm 19983 occurred ISIS Port fei_1 1 port num 18 change from UP to DOWN 17 17 28 06 30 2008 UTC alarm 19983 occurred ISIS Port fei_1 1 port num 18 remove from instance 2 ZXR10 series router switch RMON Alarm 20737 20737 6 RMON is grouped incorrectly Check whether the command input is correct 20746 20746 6 The message header received by RMON module is wrong Check whether the system running status is normal and the com mand input is correct 20747 20747 6 The message data received by RMON module is wrong Check whether the system running status is normal and the com mand input is correct 20748 20748 6 90 Confidential and Propriet
223. r and try again later If fail to retry many times please contact ZTE maintenance staff after recording the error 240 240 Fail to set the cos IP priority function Please contact ZTE maintenance staff after recording the error It may try again later 241 241 Fail to set cos IP priority function data Please contact ZTE maintenance staff after recording the error It may try again later 242 242 This priority does not exist Please check whether the command configuration is proper and the parameter configuration is correct 243 243 The same priority is already existed Informational notice No action is needed 244 244 Fail in the community list operation Please check whether the command parameter is correct and proper and try again later Confidential and Proprietary Information of ZTE CORPORATION 163 ZXR10 Alarm Handling Manual Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH 245 245 The input expression is wrong Please input the correct command 246 246 The ACL rule expression is wrong Please configure correct command 247 247 The source file does not exist Please input the correct command parameter 248 248 The target file n
224. r and the command configuration is correct 2016 2016 Fail to change the area to import summary Please check whether the command configuration is proper and correct 2017 2017 Fail to obtain area ingress It may try again later 2018 2018 Fail to delete NSSA area Check whether the command configuration sequence is proper and whether the command configuration is correct Confidential and Proprietary Information of ZTE CORPORATION 189 ZXR10 Alarm Handling Manual Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations ZTEDH 2019 2019 This keyword is not in the interface Check whether the command configuration is correct 2020 2020 A keyword with the same key already exists None 2021 2021 Fail to delete network range It may try again later 2022 2022 Fail to add network range It may try again later 2023 2023 This range is not existed Please check whether the command parameter is correct 2024 2024 OSPF is disabled Please check whether the command configuration sequence is proper and whether the command configuration is correct 190 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Cause
225. rd are mismatched when SNMP v2 is used for accessing equipment 2 The relevant configuration for SNMP sending trap is correct Please check whether any equipment administrator is accessing the equipment if it is please check whether the user name and password are consistent with the relevant configuration on the equipment if not please check whether anybody is trying to mon itor the equipment None linkUp The trap is sent when the interface changes from down to up up in both the management status and operation status 1 The interface management and operation status both are in up 2 The relevant configuration for SNMP sending trap is correct None ifIndex interface index OID 1 3 6 1 2 1 2 2 1 1 ifAdminStatus interface managing status OID 1 3 6 1 2 1 2 2 1 7 ifOperStatus interface operating status OID 1 3 6 1 2 1 2 2 1 8 258 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Information Description Triggering Criteria Recommended Operations Binding variables Information Description Triggering Criteria Recommended Operations Binding variables Chapter 4 TRAP Messages IinkDown The trap is sent when the interface changes from up to down it might be the managing status is down and the operating status is down or both changed from up to down 1 The interface operating status changes from up to down or the managing status changes from up to down 2
226. red indicates that an alarm has occurred while cleared indicates that the alarm has been cleared it is only applied to hardware alarms type Alarm type which is identified with Alarm message description Alarm message sender Note Alarm messages in the cleared status are merely system recov ery messages which need no operation ZXR10 alarm messages have 2 types hardware alarm and soft ware alarm Of which the 2 types may be divided further into more sub types Hardware alarms can be divided into environment alarms board alarms and port alarms Software alarms may be separated as more sub types as ROS DATABASE OSPF RIP BGP DRP TCP UDP IP TELNET ARP ISIS RMON ACL URPF VRRP PPP VIRUS SCAM and MAC Alarm message examples are as follows 1 Hardware alarm gt Environment alarm alarm occurred 15 41 22 09 11 2003 UTC alarm 6 occurred ENVI RONMENT Rack fan 1 wrong sent by UPC MPU 1 gt Environment alarm alarm cleared 15 51 22 09 11 2003 UTC alarm 6 cleared ENVIRON MENT Rack fan 1 normal sent by UPC MPU 1 gt Line board alarm alarm occurred 10 13 36 09 15 2003 UTC alarm 279 occurred Board Remove Interface from slot 3 sent by SMP 1 gt Line board alarm alarm cleared 10 13 51 09 15 2003 UTC alarm 279 cleared Board Add Interface at slot 3 sent by SMP 1 gt Port alarm alarm occurred 6 Confidential and Proprietary Information o
227. rietary Information of ZTE CORPORATION 193 ZXR10 Alarm Handling Manual Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH 2041 2041 Fail to add the export template It may try again later 2042 2042 Fail to add the import template It may try again later 2043 2043 Fail to delete the export template It may try again later 2044 2044 Fail to delete the import template It may try again later 2045 2045 The address and mask are mismatched Please configure correct command 2046 2046 Unknown protocol type 194 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Chapter 3 Command Configuration Error Prompt Messages Please check if the configuration is correct 2047 2047 The configuration buffer is overflowed Please delete some useless configurations and then try again 2048 2048 The command is incomplete Please configure correct command 2049 2049 Error
228. ritten license between ZTE CORPORATION and its licensee the user of this document shall not acquire any license to the subject matter herein ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice Users may visit ZTE technical support website http ensupport zte com cn to inquire related information The ultimate right to interpret this product resides in ZTE CORPORATION Revision History Revision No Revision Date Revision Reason Serial Number sjzl20095779 Contents About This Manual sssssnsnnnnnnnnnnnnnnnnnunnnnnnnnnnnnnn Alarm Over vie Wired L OVEIVIE Wii 1 Alarm Glossry OVervieW icoccoccconconccononnconanrnno na rnnnn narran 1 Message NO cotos a EARS 1 Default Severity Level sssssssssssssrrrrrrrrssrrrnrrrrrrrsrresrns 2 Alarm Recovery ccecceeee eee e cece eee e ee eee eee eae eae seat nae eae tenes 2 Alarmi TY PO iota tiees babs Sites tots A a 2 NM Level ocio ceiver eves ataei 3 CAUSO evades raed arsine Viaienhatvihavaidecuen ten nseea NNA 3 Related Alarms iii bs 4 Recommended Operations 0occcccccocnocncnnnananonann naa narnnan nos 4 Alarm Prototype Description coccoccccnccnnonnonncnnnananonaannnos 5 Alarm Description ococccconconcconcnnanonanncna narran rra rnnr narran 5 Supported device type coccccccocconnconconcnoncnnconananarnananannns 5 Appendix Description ssssssssssesssrrsrrsrrnesssrnsrrrrraernesses 5 Message Format Description rese
229. rk 4 The subsequent steps to dispose the alarms are as follows i Check whether the alarm is removed The methods in clude the alarm message does not appear or the normal system alarm appears reboot the single board or this mod ule the service recovers to normal ii Remember to record the detailed alarm processing log which includes alarm phenomenon alarm cause and the disposal methods The alarm processing log is convenient for resolving the similar problems Alarm Prototype Description It is the alarm instance that is the display information on the rack when the alarm occurs This is shown by the command show logging alarm Alarm Description Alarm description is the explanation for the rack alarms It de scribes the malfunction on the device Supported device type Supported device type lists all the device types that supports this alarm Appendix Description Appendix Description list all the points that should pay attention to for example explain that there is difference of this alarm between versions and devices Message Format Description The alarm message format is as follows lt time gt alarm lt number gt occurred cleared lt type gt lt descrip tion gt sent by lt sender gt Confidential and Proprietary Information of ZTE CORPORATION 5 ZXR10 Alarm Handling Manual ZTEHX The following table describes each field of an alarm message occurred cleared Alarm status occur
230. rol table item index No Confidential and Proprietary Information of ZTE CORPORATION 261 ZXR10 Alarm Handling Manual ZTEHX Syntax Information Description Triggering Criteria Recommended Operations Binding variables Information Description OID 1 3 6 1 2 1 16 3 1 1 1 alarmVariable monitored alarm variable OID 1 3 6 1 2 1 16 3 1 1 3 alarmSampleType monitored variable value sampling type abso lute value type difference type OID 1 3 6 1 2 1 16 3 1 1 4 alarmValue monitored variable value OID 1 3 6 1 2 1 16 3 1 1 5 alarmFallingThreshold set lower threshold of monitored variable OID 1 3 6 1 2 1 16 3 1 1 8 OSPF TRAP Message ospfVirtlfStateChange The trap is sent when OSPF virtual interface status is changed 1 OSPF virtual interface status is changed 2 The relevant configuration for SNMP sending trap is correct Please check whether OSPF virtual interface status change is nor mal if not please check whether the router interface status re lated to OSPF virtual interface is normal and the router OSPF configuration and the OSPF configuration of neighbors related to OSPF is normal if the fault remained please contact ZTE ospfRouterld router ID used to distinguish the routers in au tonomous system and the value is only value OID 1 3 6 1 2 1 14 1 1 ospfVirtIfArealId the area ID crossed by OSPF virtual connection OID 1 3 6 1 2 1 14 9 1 1 ospfVirtIfNeighbor the router ID of OS
231. rong Check whether the network connection and operation are in sound conditions 18740 18740 7 The received IP packet version is wrong Check whether the network connection and operation are in sound conditions 18741 18741 7 The received IP packet checksum is wrong Check whether the network connection and operation are in sound conditions and whether the system configuration are correct 18742 18742 7 Receiving IP packets with illegal source address Check whether the network connection and operation are normal and whether anybody is attacking the network 18743 18743 6 78 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Chapter 2 Alarm Message Receiving IP packets with illegal destination address Check whether the network connection and operation are normal and whether anybody is attacking the network 18744 18744 9 The destination address of received IP packet is unreachable Check whether the system configuration is correct 18745 18745 7 The protocol type of received I
232. rotocol fails to apply timer Alarm occured 00 01 07 01 01 2001 UTC alarm 25355 occurred LDP Timer 25356 25356 8 LDP fails to apply for LABEL resources which are insufficient Alarm occurred 00 01 07 01 01 2001 UTC alarm 25356 occurred LDP Label Confidential and Proprietary Information of ZTE CORPORATION 113 ZXR10 Alarm Handling Manual Message No Default Severity Level Cause Alarm Prototype Description Message No Default Severity Level Cause Message No Default Severity Level Cause Alarm ProtoType Description Message No Default Severity Level Cause Alarm ProtoType Description Message No ZTEDH 2535 7 25357 8 LDP fails to apply for FEC resources which are insufficient Alarm occurred 00 01 07 01 01 2001 UTC alarm 25357 occurred LDP Fec L2VPN Alarms 25856 25856 6 MAC address learned from VPLS changes E g MAC migrates from one port to another port 2585 7 25857 8 TLV is unknown to L2VPN Alarm occurred 00 01 07 01 01 2001 UTC alarm 25857 occurred L2VPN Un known L2VPN TLV 25858 25858 8 GR is enabled in L2VPN Alarm occurred 00 01 07 01 01 2001 UTC alarm 25858 occurred L2VPN GR 25859 25859 114 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Default Severity Level Cause Alarm ProtoType Description Message No Default Severity Level Cause Alarm ProtoType Description Message N
233. rrect 9515 9515 Error input channel mode Please check whether the command parameter is correct 9516 9516 Please allocate the above interfaces to the same management group first Confidential and Proprietary Information of ZTE CORPORATION 247 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH Please check whether the system configuration is correct and proper 9517 9517 Repeated interfaces exist in the management group Please check whether the system configuration is correct and proper 9518 9518 No interface in the group Please check whether the system configuration is correct and proper 9519 9519 Too many interfaces the interface quantity should be less than or equal to 16 Please check whether the command parameter is correct 9520 9520 Please allocate the above interfaces to the same vlan first Please check whether the system configuration is proper and cor rect 9521 9521 The buffer reserved for show command is overflowed 248 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No
234. rst 12433 12433 This service is bound with a Template Release the Template binding with this service 30201 30201 254 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Chapter 3 Command Configuration Error Prompt Messages acl_ipv4_entrynum is empty Basic acl and extended acl can t be configured to send to ESM at ESM_UDF mode Please configure acl_ipv4_entrynum first to make it non null 30202 30202 acl_12_entrynum is empty Link acl can t be configured to send to ESM at ESM_UDF mode Please configure acl_ 12_entrynum first to make it non null 30203 30203 acl_l2ipv4_entrynum is empty Hybrid acl can t be configured to send to ESM at ESM_UDF mode Please configure acl_ 2ipv4_entrynum first to make it non null 30204 30204 acl_ipv6c_entrynum is empty Ipv6_standard acl can t be config ured to send to ESM at ESM_UDF mode Please configure acl_ipv6c_entrynum first to make it non null 30205 30205 acl_ipv6f_entrynum is empty Ipv6_extendend acl can t be con figured to send to ESM at ESM_UDF mode Please configure acl_ipv6f_entrynum first to make
235. ry again later 1010 1010 The next hop address is illegal which cannot be the configured address for router Please input the correct parameter 1011 1011 The next hop address is illegal which can only be a direct connect network section address 174 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages Please input the correct parameter 1012 1012 The memory is insufficient Please remove some configurations not used and then try again later 1013 1013 There is no idle slot Please check whether it reaches the maximum configuration and whether it is able to try again later 1014 1014 No route is found Check whether the configuration is correct and whether the con nection is normal 1015 1015 The interface is not configured with the route discovery This is the system prompt 1016 1016 The interface has no IP address Confidential and Proprietary Information of ZTE CORPORATION 175 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Re
236. s it is 5 minutes by default The current port receives much more packets and the port is closed After a while the port opens automatically The default waiting time is 5 minutes Reduce system load nPort 0x x CPU Protect Port Upsend Close nPort 0x x Cpu Pro tect Port Upsend Open 0x x is the global port number of the in terface 122 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Chapter 2 Alarm Message 05 42 40 04 20 2001 UTC alarm 29956 cleared MIX Port 0x7 Cpu Protect Port Upsend Open on fei_4 3 sent by NPC 4 05 44 30 04 20 2001 UTC alarm 29956 occurred MIX Port 0x7 Cpu Protect Port Upsend Close on fei_4 3 sent by NPC 4 The packets received by the port exceed the alarm value and the port shuts down The default alarm value is 20 packets in 2 sec onds T128 T64 T600 T1200 N A 29957 29957 6 Available ProcessingErrorAlarm 5 When the system restores the relative sub event to the event list the event list has been deleted Alarm occurs when plugging in the NPC again It is a prompt There is no need to care about it
237. s in other slots will fail to send packets normally To solve this problem we give a limit to reset times If the times of switch network reset caused by abnormal line card exceed this threshold only alarm will be prompted and switch network will not be reset The linecard with malfunction can not work normally There is no influence on other linecards No Wait for engineer from customer service department to deal with the fault line card Pannel d NPC resets switch module over limit times d line card slot number 11 02 34 03 21 2008 UTC alarm 301 occurred Pannel 5 npc resets switch module over limit times sent by UPC MPU 1 The times of SFU reset caused by abnormal line card exceed this threshold T64E T128 N A 302 302 6 Unavailable Equipment Alarm 5 Abnormality of NPCT line card will lead to failure of SFC syn chronization In case synchronization loss still exists for switch chip on SFC after it resets repeatedly for 30 times master slave switchover of SFC will occur and alarm is sent out 24 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Influence Related Alarms Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Related Alarms Recommended Operations Alarm Prototype Description Alarm Description
238. s the system prompt 6038 6038 The event table is blank This is the system prompt 6040 6040 The RMON timer is wrong Please try again later 6050 6050 Confidential and Proprietary Information of ZTE CORPORATION 217 ZXR10 Alarm Handling Manual Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause 218 ZTEDH The start function failure Please try again later 6051 6051 No interface information Please check whether the system is running normally and whether the parameter is correct 6052 6052 The packet received from the line card is wrong Please check whether the system is running normally and whether the parameter is correct 6053 6053 The sampling type is wrong Please check whether the command configuration is correct and try again later 6054 6054 Incorrect OID Please input the correct parameter and try again later 6055 6055 Add event table incorrectly Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause
239. sage Format Error Message Description 10 10 The input parameter is illegal Input the correct parameter to try again according to the command prompt and ZXR10 Data Product Command Manual 11 11 Fail to access database Check whether the system operation is normal and the input con figuration information is correct If everything is normal contact ZTE maintenance staff after recording the error please 12 12 Fail to write to database Confidential and Proprietary Information of ZTE CORPORATION 147 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations ZTEDH Check whether the system operation is normal and the configura tion is following the normal flow If everything is correct contact ZTE maintenance staff after recording the error please 13 13 Fail to send message Check whether the system operation is normal and try again later 14 14 The user does not exist Please input the correct user name for login 15 15 The file does not exist Please input the correct file name 16 16 Incorrect file or directory name Please input the correct file or directory name 17 17 Fail to create timer Check whether the system operation is
240. sage Number Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason 252 ZTEDH Release the Template binding with other Vlan 12409 12409 This Nat ip doesn t exist in this Template Verify whether this Nat ip is configured 12410 12410 This Vlan interface has been bound in a Template Verify which Template this interface has been bound in 12411 12411 This VLan interface binds with management IP Verify whether this management ip is configured 12420 12420 This signature entry doesn t exist Create this signature entry first 12421 12421 This signature symbol doesn t exist Create this signature symbol first 12422 12422 This flow pool doesn t exist Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Alarm Reason Recommended Operations Message Number Chapter 3 Command Configuration Error Prompt Messages Create this flow pool first 12423
241. sal from the DHCPPOOL or PPP module Failed to process ippool s s the set ip pool nameippool does not exist Alarm occurred 0 29 52 08 13 2008 UTC alarm 18833 occurred IP failed to process ippool invalidPool Invalid ippool All 18834 18834 4 Unavailable ProcessingErrorAlarm 5 Ippool address block number reaches the threshold Users can not get online Turn on the IPPOOL debug to obtain more detailed information Ippool address block number reaches the threshold Force some user down line in the relative service module DHCP or PPP and let the newer access ippool bitmap has reached max number 4096 4096 is the upper threshold of IPPOOL Alarm occurred 20 33 24 08 13 2008 UTC alarm 18834 occurred IP ippool bitmap has reached max number 4096 sent by UPC RPU 2 Ippool address block number reaches the threshold 82 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Supported Devices Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Severity Level Cause Chapter 2 Alarm Message All 18835 18835 4 Unavailable QoSAlarm 3 The current ingress egress traffic utilization exceeds the set threshold 80 by default Increase the threshold Set the flow threshold input to 100 zxr10 config int fei 1 1 zxr10
242. se Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations ZTEDH No PPP example on this interface Please check whether the system configuration is correct 8509 8509 This interface does not support PPP Please check whether the command configuration is correct 8510 8510 The pool name does not exist Please check whether the command configuration is correct 8511 8511 Error IP address range Please check whether the input parameter is correct 8512 8512 There is no available memory Please check whether the configuration reaches the system per mitted maximum value and try again later after removing some useless configurations 8513 8513 The IP address range of address pool is overlapped There can t be repeated addresses in address pool Please reset it 230 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages 8514 8514 The IP address pool does not allow the IP address Please check whether the input parameter is correct 8515 8515
243. se check whether the configuration related to RIP protocol is correct and proper 17671 17671 6 Simple authentication has no keyword so no authentication for packages Please check whether the configuration related to RIP protocol is correct and proper 17672 17672 6 RIP ignores invalid packet which means packet failing to authen ticate or with incorrect version number and not supporting com mand Please check whether the configuration related to RIP protocol is correct and proper 17673 17673 6 The RIP neighbor is invalid Please check whether the configuration related to RIP protocol is correct and proper the network link status is normal and the router corresponding to RIP neighbor is running normally 17676 17676 6 The RIP interface status turns to down Please check whehter the link status is normal and whether the system is running normally 58 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Chapter 2 Alarm Message 17677 17677 6 The RIP interface status turns to up Informational message No action is required BGP Alarm 17920 17920
244. seeeeeeeeeaeeaeeaeeeas 271 DHCP TRAP MESS AC acca va voter aie ears detent Os 272 Oli 272 e Miadamnidta eeza aai 272 vrrpTrapAuthFailure neaei e a i 273 VerplirapN ewMa Stet iaa eaa nenV EN A VAa 273 IPV6TRAP Information ssssssssssssssssrrrrnrrrrssrrrerrrrrrrsrnns 274 IPVOTEStateChandE ii a aad save E ee sees 274 POE TRAP Information cccccccceeeeeeeeeeeeeeeaeeaeeeneeaeeaenaas 274 pethPsePortOnOffNotification ccccecceseeeeeeeeeeeeeeeneeeas 274 pethMainPowerUsageOnNotification eeeeeeee tees 275 pethMainPowerUsageOffNotification cceceeeeeee eee eees 275 Purpose Intended Audience What Is in This Manual About This Manual The manual is ZXR10 Router Ethernet Switch Message Manual and suited for following equipments ZXR10 GAR universal access router shorted as ZXR10 GAR ZXR10 GER universal high performance router shorted as ZXR10 GER ZXR10 T64E T128 carrier class high end router shorted as ZXR10 T64E T128 ZXR10 3900 3200 series intelligent Ethernet switches shorted as ZXR10 3900 3200 ZXR10 5900 5200 series all gigabit port intelligent routing switch shorted as ZXR10 5900 5200 ZXR10 T160G T64G T40G 10G MPLS routing switch shorted as ZXR10 T160G T64G T40G ZXR10 8900 series 10G MPLS routing switch shorted as ZXR10 8900 The manual content is based on unified ZXROS platform and suited to all equipments if with no special note or described as ZXR1
245. serriteecic trenen rer E 5 Alarm Message sssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn Y Hardware alarm 0ccoccoccccncnncnnnnnnannnnn nar n rn nar nr rra 9 Environment AlarM ooccccccccnccnncnn narran nn eee nr rr rr 9 oe E A E EA A 9 Aden 10 a a 11 ui a ini 12 G7 eis estas cans nas ca neta ua can wanna sn aese evsates beak S 13 A A A 14 Dc atea 15 A O 16 A lit eonsnd E T celehi been deicies 17 DORA OA 18 Board Alarms ii cc 22 PT PEE E A it 22 QO EEA A E A A 22 ZOD EEE NN 22 SOO EAE A E A da T 23 A E A A E 24 SOLA ANA Sola ds Os 8 24 C1 0 S Nee reece err Matar ee ee TN VO 25 SL Oi seed oiande A AA A 26 VA aii 26 A ET 27 E E EEEE A N A ANA 28 POrt Alar gorea Ee EEEa EAE VA A ond 29 A a a a cued ea aae 29 NT aA 29 BA O 29 DR ii 29 Software Alan iii a doves taveees 30 ETHOAM Alda cue A EAE AAA AERAR 30 O T 30 LEAL E A AT 31 LG DS Oeh ENE E AN N EE EEA 31 a 32 SOAG4 TN 34 30465 A A 35 A crensiaaan ve cia sees vanwedeex Mew enti ees 36 30467 it 37 ROS Alarm sass e Mech ae hoa 38 MAA T ven se oReseawek debtors ots 38 V6 386 a A a eevee 38 IO to 38 A ees ocenneina tle date E eevee ices ts 38 W639 25 ia iis nines iia 39 A eE asleep eee 39 IOZIM niana CEARN AAEN AENEAN AENEAN AAKE 40 163 L E E T 41 EIEE AE E A este taet ee 41 DATABASE Aldaia dat 42 LU ii a eee 43 16644 S HAs aote halen ha acticalases haere ee 43 T6645 ies iste Te sR ee a do 43 LO iii chads vane die bison elses An R DE tie 43 OA
246. t Power Commutate Module 1 fail to work 15 07 38 08 14 2008 UTC alarm 79 occurred Power error reason Current Power Commutate Module 1 fail to work sent by UPC MPU 1 Current Power Commutate Module 2 fail to work 15 46 02 08 14 2008 UTC alarm 79 occurred Power error reason Current Power Commutate Module 2 fail to work sent by UPC MPU 1 15 46 02 08 14 2008 UTC alarm 79 occurred Power error reason Current Power Commutate Module 2 fail to work sent by UPC MPU 1 Current Power Commutate Module 3 fail to work 15 47 32 08 14 2008 UTC alarm 79 occurred Power error reason Current Power Commutate Module 3 fail to work sent by UPC MPU 1 General alarm The power data line isn t plugged into the bic board 14 32 38 08 14 2008 UTC alarm 79 occurred Power error reason The power data line isn t plugged into the bic board sent by UPC MPU 1 Current Power work normal 15 05 08 08 14 2008 UTC alarm 79 cleared Power recover Current Power work normal sent by UPC MPU 1 Power malfunction ZXR10 T64E T128 T600 T1200 ZXR10 T64 T128 adopts old rack ZXR10 T600 T1200 adopts new rack 80 80 6 Available Equipment Alarm 2 Fan malfunction This may cause heat dissipation malfunction on the rack and the temperature increment on each single board Wait for our customer service personnel to deal with the fan mal function Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Prototype Descr
247. t bind DHCP Pol icy The user in L3 interface can not obtain the IP address Check whether the L3 interface configuring DHCP Server binds DHCP Policy Interface s has no valid binded DHCP Policy s L3 interface name of DHCP user access Alarm occurred 16 57 45 07 17 2008 UTC alarm 23819 occurred DHCP in terface vlan100 has no valid binded DHCP Policy sent by MEC 1 The L3 interface configuring DHCP Server does not bind DHCP Pol icy ZXR10 3900 5900 6900 series switch T64E T128 T600 T1200 series router 23820 23820 6 Unavailable ProcessingErrorAlarm 5 106 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Cause Influence Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Severity Level Alarm Recovery Alarm Type NM Level Chapter 2 Alarm Message DHCP access user number reaches the upper threshold The user in L3 interface can not obtain the IP address Increase the upper threshold or advise the user to go online from other interface user number have reached the s s quota u s L3 interface name u user quota number Alarm occurred 14 47 55 07 07 2008 UTC alarm 23820 occurred DHCP user number have reached t
248. t the correct address for copy command 218 218 The source file name is the same as target file name during re naming Please input the correct command parameter 219 219 It cannot be changed into the file name Please check whether the input parameter is legal and the com mand configuration is correct 220 220 It cannot create the directory Please check whether the input parameter is legal and the com mand configuration is correct 221 221 Fail to delete file Please check whether the input parameter is correct and the file is used Confidential and Proprietary Information of ZTE CORPORATION 159 ZXR10 Alarm Handling Manual Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH 222 222 Fail in dir command operation Please check whether the input parameter is correct and try again later 223 223 FTP server configuration command is wrong Please input the correct parameter and perform correct command configuration 224 224 It succeeds in FTP server configuration command execution Informational notice No action is needed 225 225 The command execution mode is wrong Please contact ZTE maintenance staff after recording the error 226
249. tem restore the relative sub event to the event list the event total number already reaches the upper threshold ZT600 T1200 29959 29959 6 Available ProcessingErrorAlarm 5 This alarm may occur when plugging in or plugging out NPC When plugging NPC because other event list member is configured the event total number already reaches the upper threshold After plugging in NPC it tries to restore interface related sub event list Now the member number is full and this alarm appears It is a prompt There is no need to care about it Add entry failed too many event items s event list name Alarm occurred An alarm 29959 level 6 occurred at 00 08 59 01 01 2001 UTC sent by UPC MPU MIX Add entry failed too many event items When the system restore the relative sub event to the event list the event total number already reaches the upper threshold G series ZXR10 6900 8900 29960 29960 5 ProcessingErrorAlarm 5 124 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Cause Influence Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Message No Default Severity Level Cause Recommended Operations Alarm Prototype Description Chapter 2 Alarm Message The number that netflow configures on the line card exceeds the upper limit specified by system The command of sampling rate of configured interface is netf low sample
250. ter table index number error 220 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages Please configure correct command 6087 6087 Channel table index number error Please configure correct command 6088 6088 Buffer control table index number error None 6089 6089 Event table index number error Please configure correct command 6601 6601 NTP cannot identify the server Please check whether the configuration parameter is correct 7001 7001 Message ID error This is the system prompt 7002 7002 Incorrect pointer to obtain synchronous message return Confidential and Proprietary Information of ZTE CORPORATION 221 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH Please try again later 7003 7003 Too short synchronous message return area length Please try ag
251. thdrawed by DHCP SERVER immediately Disable DHCP CLIENT module under the interface then configure the interface IP address by manual operation will result in lease ip cann t reclaim by DHCP server im mediately Alarm occured 15 00 13 01 22 2008 UTC alarm 23810 occurred DHCP oper ation will result in lease ip cann t reclaim by DHCP server immedi ately sent by MCP Alarm Prototype Description The user configure the IP address by manual which brings to that the IP address applied by DHCP CLIENT can not be withdrawed by DHCP SERVER immediately ZXR10 5900 23811 23811 6 Unavailable ProcessingErrorAlarm Confidential and Proprietary Information of ZTE CORPORATION 101 ZXR10 Alarm Handling Manual NM Level Cause Influence Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Prototype Description Alarm Description Supported Devices ZTEDH 5 The across network section roaming switch appears in DHCP Relay or DHCP server user But the roaming switch is off Users with roaming switch can not obtain IP address Turn on the roaming switch to let user launch DHCP request again Use the following command routerA config ip dhcp ramble verifying illegal user s from s The first s user mac address The second s L
252. the com mand configuration is correct and proper 202 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages 3015 3015 The network does not exist Please check whether the command configuration is correct 3016 3016 Error D or E type network Please configure correct command 3017 3017 Loopback network error Please configure correct command 3018 3018 Error the mask is discontinuous Please configure correct command 4001 4001 It is only the A B or C type network This is the system prompt 4002 4002 The network mask is discontinuous Confidential and Proprietary Information of ZTE CORPORATION 203 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH Please configure correct command 4003 4003 The network does not match the mask Please configure correct command 4004 4004
253. tions Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Chapter 3 Command Configuration Error Prompt Messages This is the system prompt 1082 1082 The designated item does not exist Please check whether the input parameter is correct 1083 1083 The designated item ingress is not bound Please check whether the input parameter is correct 1500 1500 DHCP server is not started Please start DHCP server 1501 1501 DHCP server is not started Please start DHCP server 1502 1502 DHCP relay is still running Please stop it first Please check whether DHCP server stops working 1503 1503 Confidential and Proprietary Information of ZTE CORPORATION 185 ZXR10 Alarm Handling Manual Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH dhcp relay is started Informational notice No action is needed 1504 1504 DHCP relay is stopped Check whether DHCP server stops working 1505 1505 DHCP server is started Please stop it first Please stop DHCP server first 1700 1700 No main RADIUS server please configure it first ple
254. try again later 3005 3005 This keyword does not exist Check whether the command configuration is correct 3006 3006 This neighbor cannot be created Check whether the command configuration is correct and whether the network connection is normal 3007 3007 This neighbor does not exist Please check whether the command configuration is correct 3008 3008 This neighbor cannot be deleted Check whether the command configuration is correct and try again later 3009 3009 The same neighbor already exists on this interface Confidential and Proprietary Information of ZTE CORPORATION 201 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations ZTEDH This is the system prompt 3010 3010 Incorrect RIP version Please check whether the command configuration is correct and whether it is consistent with the opposite end 3011 3011 No RIP network configuration Please check whether the command configuration is proper and correct 3012 3012 Error keyword Please configure correct command 3013 3013 The same key id already exists None 3014 3014 Errors redistribution Check whether the system running is normal and whether
255. ts 292 292 The input acl alias is used by other acl table number input other acl alias please Check whether the input acl alias is the one planed to input or other configuration is incorrect please 300 300 This command cannot be used at this interface None 303 303 There is a user accessing the interface configuration mode and fail to delete the interface Confidential and Proprietary Information of ZTE CORPORATION 171 ZXR10 Alarm Handling Manual Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause ZTEDH It may try again later 305 305 Fail to delete user It may try again later 306 306 Add user incorrectly Please check whether it reaches the maximum configuration Try again later 307 307 The same user exists None 308 308 The user group does not exist Please perform command configuration in correct sequence and check whether the input parameters are correct 309 309 There is illegal character in user group name 172 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Messa
256. tted at the interface Please check whether the network status is normal and the net work load is too heavy 54 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Chapter 2 Alarm Message 17420 17420 7 Packets are retransmitted at the virtual interface Please check whether the network status is normal and the net work load is too heavy 17421 17421 6 Fail to transmit MD5 report Check whether the MD5 keyword configured at the interface is correct and valid 17422 17422 6 Fail to distribute the memory Please copy and save the information then contact ZTE mainte nance staff 17423 17423 6 Receiving error request packet results in link disconnection Please check whether the interface physical link is stable 17424 17424 6 The error sequence No in DD packets the interface received re sults in link disconnection Confidential and Proprietary Information of ZTE CORPORATION 55 ZXR10 Alarm Handling Manual Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No
257. u uvlan Id 2 Find interface loop Example 10 08 19 10 29 2008 UTC alarm 23296 occurred LOOPDETECT Find interface loop in vlan 200 sent by NPC 1 Interface has a loop 69 89 DHCP Alarm 23808 23808 5 DHCP user obtains IP address and gets online DHCP user releases IP address and gets offline N A 23809 23809 5 Available CommunicationAlarm 5 100 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Cause Influence Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Message No Default Severity Level Alarm Recovery Alarm Type Chapter 2 Alarm Message The IP address obtained from DHCP CLIENT is already used in the network IP address that the interface obtained is invalid Check DHCP configuration on the device IP address s has been used s obtained IP address Alarm occured 15 52 13 01 22 2008 UTC alarm 23809 occurred DHCP IP ad dress 1 1 1 1 has been used sent by UPC 1 The IP address obtained from DHCP CLIENT is already used in the network ZXR10 5900 23810 23810 5 Unavailable CommunicationAlarm 5 The user configure the IP address by manual which brings to that the IP address applied by DHCP CLIENT can not be wi
258. unicationAlarm 5 Because the attenuation of the optical path between ONU and OLT is out of normal range or ONU and OLT optical parameter config urations are not correct optical path is abnormal and the data frame transmission is abnormal The transmission data is abnormal Check the fiber connection between ONU module and OLT module This alarm is called frame error rate alarm in EPON project This alarm can be opened and closed by using command and set alarm Confidential and Proprietary Information of ZTE CORPORATION 135 ZXR10 Alarm Handling Manual ZTEHX Alarm Description Prototype Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype switch alarm monitor direction and alarm threshold In default this alarm is enabled and the monitor direction is up down link the value is 1 unit 10 9 If the alarm need to be closed con figure alarm frame error rate disable on OLT interface If the monitor direction and threshold need to be modified configure the command alarm frame error rate direction lt direction gt tthrr essholld lt threshold gt on the OLT interface Epon alarm frame error rate occour at d in s direction dindicate frame error rat value when alarm occurs sindicate the monitor direction when frame error rat alarm oc curs The monitor directions are as follows upli
259. use Recommended Operations ZTEDH Please check whether the command parameter is correct 9503 9503 The group ID range is 1 64 This is the system prompt 9506 9506 The group ID is used by another interface Please check whether the input parameter is correct and proper 9507 9507 Error interface configuration mode Please check whether the command configuration is proper and correct 9508 9508 This group does not exist Please check whether the command parameter is correct 9510 9510 The system memory is insufficient Please try again after deleting some useless configurations of the system 246 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages 9511 9511 Some interfaces in the group do not exist Please check whether the system configuration is proper and the input parameter is correct 9512 9512 There are too many group members Please check whether the system configuration is proper 9513 9513 Fail to configure the port auto mode Please try again later 9514 9514 No group Please check whether the command parameter is co
260. valid parameter sent by MEC 1 144 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level Cause Influence Recommended Operations Alarm Description Prototype Alarm Description Supported Devices Chapter 2 Alarm Message ONU remote configuration command is invalid ZXR10 8900 33297 33297 6 ProcessingErrorAlarm 5 ONU remote configuration fails for wrong onu status or capability ONU remote configuration is invalid Please check if the ONU current status and capability allow to con figure this command ONU s remote configuration fails for wrong onu status or capa bility SOLT sub interface name Example 00 54 34 12 14 2008 UTC alarm 33296 occurred EPON ONU epon olt_2 16 2 remote configuration fails for wrong onu status or capability ONU status is wrong or ONU don t have the capability to configure this command ZXR10 8900 Confidential and Proprietary Information of ZTE CORPORATION 145 ZXR10 Alarm Handling Manual ZTEHX This page is intentionally blank 146 Confidential and Proprietary Information of ZTE CORPORATION Syntax Message No Cause Recommended Operations Message No Cause Recommended Operations Message No Cause Chapter 3 Command Configuration Error Prompt Messages Table of Contents MESSI DO FOIE sr 147 Error Message DESEO a ape 147 Mes
261. vel Cause Influence Related Alarms Recommended Operations Alarm Description Prototype Chapter 2 Alarm Message QOS Alarm 4 The utilization ratio that process uses CPU resource reaches de fined medium threshold Response to operation may be slow 16924 16926 It is normal that CPU resource is consumed too much in a short time Use the show task detail command to view the utilization ratio that process uses CPU resource Task s current CPU load is d 02d exceeds the interme diate Threshold d The first s is process name type The first d and second d are peak value of utilization ratio that process uses CPU resource The third d is medium threshold that process uses CPU resource Alarm Generated An alarm 16924 level 4 occurred at 00 54 07 01 01 2001 UTC sent by UPC MPU 1 OAM Task ACL current CPU load is 40 0 exceeds the intermediate Threshold 35 Alarm Recovery An alarm 16924 level 4 cleared at 00 55 07 01 01 2001 UTC sent by UPC MPU 1 OAM Task ACL current CPU load is 30 0 under the intermediate Threshold 35 The utilization ratio that process uses CPU resource reaches de fined medium threshold 6989 16926 16926 Available 5 QOS Alarm 4 The utilization ratio that process uses CPU resource reaches de fined low threshold Response to operation may be slow 1692416925 It is normal that CPU resource is consumed too much in a short time Use the show task detail command t
262. vent localmac 00d0 d0c6 5e27 peermac 00d0 d0c0 7d81 on fei_1 1 sent by NPC 1 8 00 16 14 01 01 2001 UTC alarm 16131 occurred ETHOAM Interface occur error frameperiod event localmac 00d0 d0c6 5e27 peermac 00d0 d0c0 7d81 on fei_1 1 sent by NPC 1 9 00 16 14 01 01 2001 UTC alarm 16131 occurred ETHOAM Interface occur error framesecond event localmac 00d0 d0c6 5e27 peermac 00d0 d0c0 7d81 on fei_1 1 sent by NPC 1 10 00 16 14 01 01 2001 UTC alarm 16131 occurred ETHOAM Interface occur error symbol period event localmac 00d0 d0c6 5e27 peermac 00d0 d0c0 7d81 on fei_1 1 sent by NPC 1 The device occurs related fault event such as link fault dying gasp fault and fault frame event All series This alarm can be available from V4 8 22 30464 30464 6 Available ProcessingErrorAlarm 5 Local configuration has fault The peer receives faulty CC message or doesn t receive CC message that local sends Local prints alarm Link fault check link state check configuration sS MD d MA d MEP d s The first od is the ID of MD with RDI alarm The second d is the ID of MA with RDI alarm The third d is the ID of MEP with RDI alarm The first s is someRDIdefect when alarm appears the alarm is the content which shows When alarm disappears this character string is empty The second character string content is has received a packet from some remote MEPs with RDI flag when alarm appears the alarm is the content wh
263. verity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause ZTEDH The port that TCP is to start is under application Clear existent TCP connection and then try again 18438 18438 7 The IP version of packet received by TCP is incorrect Check whether the link status and network connection is normal 18439 18439 7 The checksum of packet received by TCP is wrong Check whether the network connection and operation is normal 18440 18440 6 The silent time received by TCP does not end Check whether the network connection and operation are normal 18450 18450 5 TCP receives packets with BGP MD5 authentication failure Check whether MD5 authentication setting is correct 18451 18451 4 TCP receives packets with wrong header length 72 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No
264. very 10 58 10 08 26 2008 UTC alarm 33292 cleared EPON Epon alarm optical power overflow recover sent by NPC 3 142 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level Cause Influence Alarm Description Prototype Alarm Description Supported Devices Message No Default Security Level Alarm Type NM Level Cause Influence Alarm Description Prototype Chapter 2 Alarm Message Epon optical power overflows EPON project of 4822 33293 33293 5 CommunicationAlarm 4 A ONU gets off line Alarm occurs Alarm occur Epon alarm onu get offline Alarm recovery Epon alarm onu get online Example Alarm occur 9 42 31 08 26 2008 UTC alarm 33293 occurred EPON Epon alarm onu get offline sent by NPC 3 Alarm recovery 9 44 36 08 26 2008 UTC alarm 33293 cleared EPON Epon alarm onu get online onuregister successfully sent by NPC 3 ONU gets off line EPON project of 4822 33294 33294 5 CommunicationAlarm 3 Optical protection switch occurs on EPON Optical protection switch occurs on EPON Epon alarm optical protection switch from interface s to inter face s The first sindicate the interface name before switchover The second s indicate the interface name after switchover Example Confidential and Proprietary Information of ZTE CORPORATION 143
265. w P48F P192 Feig Feiog ge4b ge4d vlanfeig vlan feigo vlan ge4b vlan ge4d qing feig qing feigo qing ge4b qinqge4d p3c p12 p48 cp3 A3c A3D A12 BFD session can t be established Please establish BFD session on the interface supporting it Session CANNOT be created on interface s sindicate interface name Example An alarm 30213 level 5 occurred at 00 07 31 01 01 2001 UTC sent by UPC RPU 1 BFD Session CANNOT be created on interface smartgroup1 Establish BFD session on the interface which doesn t support it Confidential and Proprietary Information of ZTE CORPORATION 127 ZXR10 Alarm Handling Manual Supported Devices Message No Default Severity Level Alarm Type NM Level Cause Recommended Operation Alarm Prototype Description Supported Device Message No Default Severity Level Alarm Type NM Level Cause Recommended Operation Alarm Prototype Description Alarm Description Supported Device ZTEDH All series UDLD Alarm 29696 29696 5 EnvironmentalAlarm 5 The neighbourhood is established between UDLD port and this port Check whether there is self loop in the port If self loop exists check whether it is necessary to remove the self loop interface build udld neighbour with itself on s s interface name 00 01 28 01 01 2001 UTC alarm 29696 occurred UDLD inter face build udld neighbour with itself on gei_1 25 sent by MCP ZXR10 3900 6900 29697 29697
266. warding is abnormal The corresponding hardware reboots No 26 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Recommended Operations Alarm Prototype Description Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Related Alarms Recommended Operations Chapter 2 Alarm Message Check whether the board link forwarding is normal whether the hardware works normally Alarm occurred NP d link exception cause s S warning d board number The first s is the hardware name 870874FPGASFCBOARD The second s is the action reset rotate Example 15 29 12 08 09 2008 UTC alarm 311 occurred Board link ex ception cause 874 reset warning sent by NPC 9 15 28 29 08 09 2008 UTC alarm 311 occurred Board link ex ception cause two 870 reset warning sent by NPC 9 15 29 30 08 09 2008 UTC alarm 311 occurred Board link ex ception cause FPGA reset warning sent by NPC 9 15 44 23 08 09 2008 UTC alarm 311 occurred Board link ex ception cause SFC rotate warning sent by NPC 9 15 46 16 08 09 2008 UTC alarm 311 occurred Board link ex ception cause board reset warning sent by NPC 9 The board link forwarding is abnormal which brings to something wrong in the corresponding hardware T64E T128 T600 T1200 N A 312 312 5 Available Equipment Alarm 2 Alarm occurred The board
267. wens 161 NO 161 O oe 161 Di ca 161 LI A AA AAA A AAA 162 E OO 162 A iia 162 A O unde ere 162 A A EA E A E 163 QA E A O E ET 163 242 a iaa 163 A E EEE EA E E T E 163 DA seco A des 163 A EEE E A A 164 A a 164 a T EAA E A O oeeikdaltaneees 164 DA Be EA AA aie sats v ies caignut ynttuvectaaeyahs 164 290 ii datos eieededescvereedeeeviedednedie ss 164 201 iii A A OA 164 DOL A 165 A are be cated Late aide tacitly ind dal esas 165 LA 165 EA 165 DO ot 165 DOT is tycdlag aaa a a ea rats 166 DO A teeta AA 166 MO ii A A A A AA 166 260 ii A A cd tenes venir eeeie se eee8 166 DO e 166 DA A A AA 166 A vel cueeniesivex a eeenaneea te cans 167 2A Te E E A pcalueeeepemenee aie 167 A AAEE E E O 167 268 EE E E E tereihdebeeanres 167 MUDA A A pni i 167 268 ii ld 168 DO A AAA alata dial 168 DA ia 168 AT o EEE E eteines reaps ab eds pe wag A e Eee 168 OE 168 A A O 168 Do 169 La a iaa 169 TR E E NO ON 169 A E eek Coeeieatet wi pow awe eeaaGied we ce eaneled sewer nes 170 Pko a cas eid vant sine Pate E sev Teaesa ee eiaseh subsaene bev ieoea ewes 170 A E ines dada O 170 285 ii AR AA AAA AA O peedeis 170 288 it AA AA A A AR 170 A O 171 LID A a aa 171 292 a duane bistawed A 171 A Aa 171 EOE har O 171 A O 172 A e 172 BOT ri A A E 172 A 172 O 172 A O dere aes 173 A aiine a ava damrewe Sagi a 173 LOO S ek Mia O gece anetes cuatubt seus euch ce sia cak es 173 OO 173 OO iii ii a Uia 173 LOOG oi A 173 LOOT iii a devi eevee 174 UI 174 A
268. whether OSPF status shifts is normal according to the dis played alarm message If it is abnormal please check whether the configuration is correct and the corresponding virtual link port status is correct 17410 17410 6 The neighbor status shifts Check whether the OSPF status shifts is normal according to the displayed alarm message If it is abnormal please check whether 52 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Chapter 2 Alarm Message the configuration is correct and the interface status connected with neighbor is correct 17411 17411 6 The virtual neighbor status shifts Check whether the OSPF status shifts isnormal according to the displayed alarm message If it is abnormal please check whether the configuration is correct and the virtual link interface status connected with neighbor is correct 17412 17412 6 Port authentication fails Check whetehr the set authentication password of adjacent equip ment at the interface corresponding to home equipment is consis tent with the configuration on home equipment 17413 17413 6 Virtual port authenticati
269. wo magnify the maximum threshold the first parameter For example use maximum routes 40 warning only instead of maximum routes 4 warning only The routes warning limit of s is exceeded s is the vpn name that generates the alarm An alarm 18196 level 6 occurred at 00 01 02 01 01 2001 UTC sent by MCP DRP The routes warning limit of VPN1 is exceeded The input vrf routing exceeds the configured alarm threshold T128 69 70 Confidential and Proprietary Information of ZTE CORPORATION ZTEDH Appendix Specification Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Chapter 2 Alarm Message N A TCP Alarm 18433 18433 6 TCP waiting timeout duration does not end Please wait patiently 18434 18434 6 TCP starts TCB block incorrectly Restart TCP 18435 18435 6 TCP starts too many connections Close or clear some TCP connections 18436 18436 6 TCP sends the message of who am I Please check whether the local TCP address is set 18437 18437 6 Confidential and Proprietary Information of ZTE CORPORATION 71 ZXR10 Alarm Handling Manual Cause Recommended Operations Message No Default Se
270. work One or two of the 8 fans work abnormally The abnormal fan number is behind Num For example Num 3 5 14 55 08 08 14 2008 UTC alarm 80 occurred Fan error reason Current Trunk Bottom Fan Num 3 4 7 8 fail to work sent by UPC MPU 1 Current Cabinet Top Fan Num fail to work One or two of the 6 fans work abnormally The abnormal fan number is behind Num For example Num 3 5 14 57 38 08 14 2008 UTC alarm 80 occurred Fan error reason Current Cabinet Top Fan Num 3 4 fail to work sent by UPC MPU 1 Confidential and Proprietary Information of ZTE CORPORATION 21 ZXR10 Alarm Handling Manual Alarm Description Supported Devices Appendix Specification Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Cause Recommended Operations Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause ZTEDH Corrent alarm Both old and new racks can generate this alarm is as follows i Fan recover Current Cabinet Trunk Fan work normal 14 58 38 08 14 2008 UTC alarm 80 cleared Fan recorver Current Cabinet Trunk Fan work normal sent by UPC MPU 1 Fan malfunction T128 T64 T600 T1200 T64 T128 adopts old rack T600 T1200 adopts new rack Board Alarms 279 279 3 The line board is offline Check whether the line board is unplugged normally or the board offline is caused by abnormal line card 293 293
271. y be that the trial run fails when updating the version The command updatever activate in privilege mode can be used to remove the trial run alarm Back version is running now for loading update version failed 14 27 32 03 21 2008 UTC alarm 16392 occurred ROS Back version is running now for loading update version failed sent by MEC 1 The current version is the rollback The reason may be that the trial run fails when updating the version CE amp PTN 6100 CE amp PTN 6100 CE amp PTN version supports this alarm 16393 16393 5 Unavailable CLASS_NOTIFY 5 Confidential and Proprietary Information of ZTE CORPORATION 39 ZXR10 Alarm Handling Manual A Cause Recommended Operations Alarm Prototype Description larm Description Supported Devices 40 Appendix Specification Message No Default Severity Level Alarm Recovery Alarm Type NM Level Cause Influence Recommended Operations Alarm Prototype Description ZTEDH A prompt appears succeed to download and upgrade the version but fail to write the upgrade rollback No Downloading update version file successfully but setting the flag failed Example 14 29 01 03 21 2008 UTC alarm 16392 occurred ROS Down loading update version file successfully but setting the flag failed sent by MEC 1 A prompt appears succeed to download and upgrade the version but fail to write the upgrade rollback CE amp PTN 6100 CE amp PTN 8900