Home

kf202 uv-c light sanitizer

image

Contents

1. federal laws regulations and guidelines Problem How do clean the UV C Light Sanitizer solution Wipe unit with a soft cloth VERY GENTLY Product Specifications e UV Wavelength UV C 253 7nm e Product Size WOKS ALS e Product Weight 140g e UV C Lamp Power AW DC Lamp UV Industrial Standard e Power Supply 4 AA Alkaline batteries e Operation Temperature 32 F 122 or 0 C 50 C e Storage Temperature 32 F 158 or O C 70 C Warning The materials used in this product may create an exposure to chemicals known to the state of California to cause cancer birth defects or other reproductive harm This warning is required by Section 25249 6 of the California Health and Safety Code PPJ Mark Feldstein amp Associates inc Maumee Ohio 43587 www markfeldstein com Caution e DANGER Ultraviolet light UV light can be harmful to skin and eyes It is important to use the UV C Light Sanitizer properly e mproper operation of the UV C Light Sanitizer may cause injury Read and understand all warnings prior to operating the UV C Light Sanitizer e Keep out of reach of children Do not look directly into the UV light Do not use the UV C Light Sanitizer on any part of the body Do not touch the UV C Light Sanitizer lamp Never disassemble the UV C Light Sanitizer Removal or tampering with the electronic circuit board or lamp assembly may Cause injury or damage the UV C Light Sanitizer and the warranty wil
2. Sanitizer is an important precaution but not the only precaution that one should take User Warning Do not look directly into the lamp and do not expose skin under the UV C light Do not allow any impact to the UV C lamp If the UV C lamp is cracked chipped or damaged do not operate While the UV C lamp is quite durable our warranty does not cover a lamp breakage This UV C lamp contains a small amount of Mercury The Mercury content of this product meets RoHS requirements less than 05mg Dispose of the UV C Light Sanitizer including the UV C lamp and any residue thereof in compliance with all relevant local state and federal laws regulations and guidelines This is not a toy Please keep it away from children Never allow the UV C lamp to be pointed at your eyes or any part of the body Children should never operate this device Do not use this device on pets Do not face the UV C lamp towards other people Do not use this device on any type of food Problem Cannot turn UV C Light Sanitizer off solution Press silver button once while unit is still in operation Problem Unit and or lamp has broken can this be fixed solution If the lamp is cracked chipped or damaged do not attempt to operate While the UV C Light Sanitizer lamp is quite durable our warranty does not cover lamp breakage Dispose of the UV C Light Sanitizer including the UV C lamp and any residue thereof in compliance with all relevant local state and
3. Suggested Application Areas Personal Items Home Toothbrushes Pillows Bedding Linens Razors Cutting boards Countertops Brushes combs Bathrooms Pacifiers Changing Tables Diaper Pails Toys High Chairs Cell Phones Phones Remote Controls Keyboards Door Knobs Offices Public Places Telephones Hospitals Fax Machines Copiers Restaurants Keyboards Locker Rooms Furniture Hotels Bathrooms Cars UV C Light Sanitizer Trouble Shooting Guide Problem Power Light will not come on solution Check to ensure batteries are working and properly inserted Do not mix old and new batteries Do not mix alkaline and rechargeable Nickel cadmium batteries Problem Power Indicator came on and is is not flashing but there is no UV C Light solution Press and hold the silver button for 3 seconds the green LED indicator light will begin flashing Then press the silver button a second time to turn on the UV C Light If the silver button is not pressed within one minute after LED indicator light begins flashing the UV C Light Sanitizer will automatically shut off e Low batteries e UV C Light Sanitizer in is in vertical or lamp face up position UV C Light Sanitizer contains a safety switch to protect the user or others from direct eye contact with the UV C light Return sanitizer to horizontal or lamp face down position and light will turn back on Problem Light keeps shutting off though the green LED indicator light remains on solution UV C Lig
4. e and the lamp is turned face up or in a vertical position the UV C light will automatically turn off When the unit is turned back face down or horizontal the UV C light will automatically turn back on This is a safety feature that protects user or others from direct eye or skin contact with the UV C light Safety Shut Off Facing Up eS Unit On Facing Down r aan J Operation 1 Insert Battery Open the battery cover Insert 4 AA Alkaline batteries into the battery compartment and close the cover UV C Light Sanitizer is ready to be used 2 To Turn On Operate Oftf A ACTIVATE Press and hold the silver button for 3 seconds The green LED indicator light will begin flashing The bulb will not light yet but the unit is now activated B LIGHT ON Press the silver button a second time to turn on the UV C light Press the silver button a third time to turn the UV C light off C POSITION UNIT Hold the UV C Light Sanitizer in a horizontal position 1 2 inches above the surface to be sanitized with the light facing down D OPERATE UNIT Slowly wave the UV C Light Sanitizer back and forth 1 2 inches over the surface to be sanitized for 30 seconds Repeat scanning 2 3 times for additional disinfection The closer the UV C Light Sanitizer is to the object the more effective it will disinfect E TURN OFF UNIT Simply press the silver button once while UV C light is still on F LOW BATTERY WARNING When Ba
5. ht Sanitizer in is in vertical or lamp face up position UV C Light Sanitizer contains a safety switch to protect the user or others from direct eye contact with the UV C light Return sanitizer to horizontal or lamp face down position and light will turn back on The UV stands for Ultra Violet light Ultraviolet light represents the frequency of light between 100 nanometers nm and 400nm and cannot be seen with the naked eye Within the UV spectrum lie three distinct bands of light UV A UV B and UV C e UV A 400 31 5nm The long wave UV light 315nm to 400nm or UV A refers to what is commonly called black light This is the longest wavelength region and lowest energy it represents the largest portion of natural UV e UV B 815 280nm The UV B 280nm to 315nm or midrange UV causes sunburn e UV C 280 100mm The Germicidal UV Light 100nm to 280nm or UV C is effective in microbial control The most effective frequency for microbial destruction is between 280nm and 200nm within this UV C band Therefore as long as the nm frequency of Germicidal lamps have been well controlled within the range then the microbial will be significantly reduced Opportunities for infection are abundant and virtually everywhere so it is important to realize that use of the UV C Light Sanitizer does not guarantee that the user will avoid illness To avoid microbial infection one must take a wide range of precautions Use of the UV C Light
6. l be voided e Do not allow anyone to use the product until they fully understand proper operating procedure and warnings e Do not improperly dispose of the lamp of this product e Do not use the UV C Light Sanitizer as a light source e Remove the batteries when not in use for long periods e For the best performance always keep the UV C Light Sanitizer clean and avoid stains e n case the UV C Light Sanitizer gets dirty wipe it with a soft cloth VERY GENTLY e Do not use in manner other than instructed in this User Manual Features 1 One button operation Easy to operate 2 Automatic Patent Pending Roller Ball Safety Shut Off Switch 3 Wave over surfaces to sanitize in seconds 4 Portable and light weight One button Operation Roller Ball Safety Shut Off KF202 UV C LIGHT SANITIZER User Manual PLEASE READ ALL INSTRUCTIONS BEFORE USING THIS SANITIZER Thank you for purchasing our UV C Light Sanitizer one of the most advanced bacteria reducing tools in the world The UV C Light Sanitizer can help you and your family to significantly reduce infectious microorganisms and germs such as fungus mold bacteria and viruses from your home office or travel environment By following these instructions and safeguards you and your family will benefit from the use of your UV C Light Sanitizer for many years to come Please Note Patent Pending Roller Ball Safety Shut Off Switch When the unit is in us
7. ttery Voltage reaches down to 3 8v UV C Light Sanitizer will start beeping for about 10 seconds If no battery replacement is made after the beep warning unit will automatically turn off the power Please note that average battery life is 3 hours with continuous use Note The UV C Light Sanitizer will not turn on if there is no second press Step B If the silver button is not pressed within one minute after the unit has been activated Step A the UV C Light sanitizer will automatically shut off and the green LED will stop blinking

Download Pdf Manuals

image

Related Search

Related Contents

SABB Road Installation Guide    LG LMVM2075 User's Manual  Targus TSS137EU  JVC KD-LX10 Instruction Manual  Guide Couleurs et Matériaux du Tarn  Philips HP8360    User Guide  Manuel d`utilisation  

Copyright © All rights reserved.
Failed to retrieve file