        Dome Heat Shrinkable Fiber Optic Splice Closure (FOSC)
         Contents
1.     Entry exit tube single     5 2 Step Two  Determine length of fiber cable to be fixed and stripped inside FOSC  5 2 1 If all fibers are for branch splicing  please refer to Drawing 2 A  for stripping length   5 2 2 If some fibers are for straight through  while others are for branch splicing  please refer to  Drawing 2 B  for stripping length   5 2 3 See Drawing 2     CY Fiber Optic Splice Closure FOSC SPM037 12 1 12    Important issues  1  Reserve enough length of fiber cable to be spliced   2  Stripping length also could be decided by customers according to    installation requirement    90mm sealing and fixing length of fiber cable inside entry exit tube    Drawing  2  A       90mm sealing and fixing length of fiber cable inside entry exit tube         Fiber cable       for straight through after being winded     Drawing  2  B    5 3 Step Three  Strip off protective coat of fiber cable and fiber    5 3 1 Strip off protective coat of fiber cable from the temp  locating mark with the cutter and the    Temp  locating mark       stripper  please refer to Drawing 2 for stripping length  Stripping length also could be decided  according to installation requirement     5 3 2 See Drawing 3    Important issues  If it is difficult to pull all the protective coat of fiber cable at one time  strip it off    section by section to avoid fiber breakage     Stripping terminal fiber cable        Entry terminal fiber cable    Gutta Drawing 3    GRY    Fiber Optic Splice Closure FOSC SPM0
2.    Dome Heat Shrinkable Fiber Optic Splice Closure  FOSC     FOSC SPM037 12 1 12    Installation Manual    2014    GORY    Fiber Optic Splice Closure FOSC SPM037 12 1 12    1  Scope of application    This Installation Manual suits for the Fiber Optic Splice Closure  Hereafter abbreviated as FOSC   as the    guidance of proper installation     The scope of application is  aerial  underground  wall mounting  duct mounting and handhole  mounting  The    ambient temperature ranges from    40  C to  65  C     2  Basic structure and configuration    2 1 Dimension and capacity       Outside dimension  Height x Diameter     288mm X 178mm       Weight  excluding outside box     1550 g    1740g       Number of inlet out ports    4 pieces in general       Diameter of fiber cable    8mm 20 mm       Capacity of FOSC       Bunchy  4 48  cores           2 2 Main components                                              No    Name of components Quantity Usage Remarks  1 FOSC cover 1 piece Protecting fiber cable splices   Height x Diameter  in whole 208mm x 132mm  2 Fiber optic splice tray   1 piece Fixing heat shrinkable Suitable for    FOST   Max  4 protective sleeve and holding   Bunchy 4 6 8 12 cores   trays  fibers  3 Fiber holding tray 1 piece Holding fibers with  protective coat  4 Base Iset Fixing internal and external  structure  5 Plastic hoop 1 set Fixing between FOSC cover  and base  6 Seal fitting 1 piece Sealing between FOSC cover  and base  7 Pressure testing valve After inject a
3.  E Hig x     Ze   fe  am         2       FOST cover    protective coat    Fiber    Drawing 5    ep rove        at shrinkable fixing    sleev e mass     Adhesive tap     Aanesive tape  Fixing device  reinforced core       A           5 E   8 z  2 av ie x      2 2     5 3 EE E  2       gt   E a 2 2 5 5  s R2 2 2    x5 9 a    Es f  5    23 E   amp  g   m      5 6 Step Six   Splice fibers  5 6 1 Follow user manual of fusion splicing machine to splice fiber     Important issue  pay attention to the twist and bend of fiber    5 7 Step Seven  Install heat shrinkable protective sleeve and house fibers   5 7 1 When having completed splicing the fibers  the first fiber ring should be housed on the farthest  side of FOST  the remaining fiber optic should be winded  forming a ring with diameter not less  than 80mm  then put it into FOST  Fiber Optic Splice Tray  together with heat shrinkable  protective sleeve    Firstly fix heat shrinkable protective sleeve into the slot  then enlarge the diameter of fiber ring  properly     5 7 2 See Drawing 6    Important issue  pay attention to the twist and bend of fiber     CY Fiber Optic Splice Closure FOSC SPM037 12 1 12               Fiber  bunchy or  ribbon     Heat shrinkable  protective sleeve   bunchy or ribbon     Fixing slot of heat  shrinkable protective sleeve   bunchy or ribbon      bunchy or ribbon     Nylon tie Nylon tie    Fiber with  protective coat    Fiber with  protective coat    Drawing 6    5 8 Step Eight   Check up comprehensi
4.  name and  model of the product  etc   The fibers reserved are to be winded in fiber optic splice  Fiber storage tray  FOST   the length of fibers housed in FOST    is  gt 1 6m  the curved radius is  gt 30mm  During the  device installation and maintenance  there should be no  attenuation on fibers   P Inside FOSC  metallic components of fiber cables has the  Electrical   i   i  Sins functions of electrical putting through  earthing  jointing              device connection and disconnecting  It is possible to install At least 3  earthing deriving device outside the housing sets  After sealing according to the stipulated operation sampled  Seali procedures  the injected air pressure is 100KPa 5Kpa  each time  ealing      formance when immersed in clean water of normal temperature for  P 15 minutes  there should be no air bubbles  then observed   At least 3 sets  for 24 hours  there should be no change of air pressure  sampled each  After reopening and resealing according to the stipulated ume  operation procedures  the injected air pressure is 100KPa  Re sealing   5Kpa  when immersed in clean water of normal  performance   temperature for 15 minutes  there should be no air  bubbles  then observed for 24 hours  there should be no  change of air pressure   P Bearing pull is  800N at axle orientation  there should be  ull    no breakage on the housing   Punching Bearing pressure of 2000N 10cm for 1 minutes  there  should be no breakage on the housing  Impact Bearing impact energy
5.  of 16N m  3 times of impacts there          should be not breakage on the housing                za 14     GORY    Fiber Optic Splice Closure FOSC SPM037 12 1 12       Bending    The spot between the FOSC and seal fitting can bear  bending tension of 150N at bending angle of  45   for 10  circles  there should be no breakage on the housing       Torsion       Bearing torsion 50N  m  10 circle at torsion angle   90    There should be no breakage on the housing        Temperature  circle    Injected air pressure of 60KPa  5 KPa  the temperature  circle ranging from  40  C  65   C  10 times of the circular  tests  one circular consists of high temperature for 2 hours    indoor temperature for 2 hours   low temperature for 2  hours   indoor temperature for 2 hours   when the  pressure declines  the amplitude is  5Kpa  immerse the  swatch in clean water of normal temperature for 15  minutes  there should be no air bubbles        Voltage  resistance  strength    After sealing the FOSC according to the stipulated  operation procedures  immerse it in clean water of normal  temperature in 1 5m depth for 24 hours  there should be  no breakdown or arc over between the metallic  components of the FOSC  between metallic components  and the ground at DC 15KV for 1 minutes           Isolating  resistance       After sealing the FOSC according to stipulated operation  procedure  immerse it in clean water in 1 5m depth for  24h  the isolating resistance between the metallic  components of th
6. 37 12 1 12    5 4 Step Four     Separate fiber cores and prepare work prior to fixing fiber cable    5 4 1    5 4 2    5 4 3    5 4 4  5 4 5    5 4 6  5 4 7    Wind 2 layers of insulation tape on protective coat of fiber core for protection  Meanwhile  get   rid of the stuffing to separate fiber core and clean them  Form a ring with the diameter of   100mm or so and fix it on the fiber temporarily by adhesive tape    Depending on fiber cable stripped  the following two cases are available       All fibers are to be branched after being spliced completely       Some of fibers are for straight through after being winded  while the others are for branch  splicing    The FOSC is provided with 3 single entry exit tubes which suit for single fiber cables with max    diameter    16mm and 1 mass entry exit tube which suits for 1 piece of fiber cable with max    diameter    20mm or 2 pieces of fiber cables with max  diameter    15mm or multi pieces of   fiber cables with short diameter    Mass entry exit tube is required if some fibers are for straight through    The corresponding entry exit tube cover could be slightly knocked out with screwdriver from   inside to outside according to number and diameter of fiber cable required    Reserve reinforced core in 70mm length and cut off the unnecessary ones     See Drawing 4 and Drawing 5     Important Issues  Entry exit tubes are to be selected accurately to make it easy for splicing and    sealing     CY Fiber Optic Splice Closure FOSC S
7. PM037 12 1 12       Adhesive tape  Fiber          Straight through fiber  with protective coat        Adhesive tape    Adhesive tape                      Fiber with  protective coat  Drawing 4       protective coat       Reinforced core  Fiber with    Reinforced core             Fiber cable 1   Fiber cable 2   Fiber cable 3                 Je     Je   gt           5 5 Step Five   Fixation of reinforced core  and pyrocondensation  fixation  amp  sealing of  fiber cable   5 5 1 Insert fiber cable into the corresponding heat shrinkable fixing tube  further insert the them into  entry exit tube at the bottom of FOSC    5 5 2 Demount fixing nut of reinforced core with a special wrench  plastic one   which is to be  inserted into the fixing slot afterward and tighten it  Then retighten it with a metal wrench  the  metal wrench is to be provided by operator     5 5 3 Hitch heat shrinkable fixing sleeve to the fiber cable till its root by hand    5 5 4 Please refer to Drawing 5 for installing branching clip    5 5 5 Heat shrinkable fixing sleeve with fire sprayer to make it hugging entry exit tube  and fiber cable to reach complete sealing    5 5 6 See Drawing 5   Important issue  1  Fixing nut of reinforced core should be tightened    2  While heating  heat shrinkable fixing tube should shrink evenly  and there     9      CY Fiber Optic Splice Closure FOSC SPM037 12 1 12    should be no bubbles  pores and other defects inside the tube        2  Sh 8  D v     E 2  on gs       See    
8. e FOSC  between the metallic  components and the ground should be   2x10 M          At least 3 sets  sampled each  time       At least 3  sets  sampled  each time            15     
9. inkable  14   Insulating tape 1 reel Additional winding of cable       3  Necessary tools for installation    3 1 Supplementary materials  to be provided by operator        Name of materials    Usage       Scotch tape    Labeling  temporarily fixing                   Ethyl alcohol Cleaning  Gauze Cleaning  3 2 Special tools  to be provided by operator   Name of tools Usage  Fiber cutter Cutting off fiber cable       Fiber stripper    Strip off protective coat of fiber cable          Combo tools       Assembling FOSC             GRY    Fiber Optic Splice Closure FOSC SPM037 12 1 12    3 3 Universal tools to be provided by operator        Name of tools    Usage and specification       Band tape    Measuring fiber cable       Pipe cutter    Cutting fiber cable       Electrical cutter    Take off protective coat of fiber cable       Combination pliers    Cutting off reinforced core             Screwdriver Crossing Paralleling screwdriver  Scissor Cutting off aramid yarns  Waterproof cover Waterproof  dustproof       Metal wrench             Tightening nut of reinforced core       3 4 Splicing and testing instruments  to be provided by operator        Name of instruments    Usage and specification       Fusion Splicing Machine    Fiber splicing       OTDR    Splicing testing       Provisional splicing tools    Provisional testing          Fire sprayer          Sealing heat shrinkable fixing sleeve       Notice  The above mentioned tools and testing instruments should be provided b
10. ir  it is used for   Configuration as per  pressure testing and sealing   requirement  testing  8 Earthing deriving 1 set Deriving metal parts of fiber  devi cables in FOSC for earthing  evice    connection             GORY    2 3 Main accessories and special tools    Fiber Optic Splice Closure FOSC SPM037 12 1 12                                                                No    Name of accessories Quantity Usage Remarks  1 Heat shrinkable protective   12 pieces Protecting fiber splices  sleeve  2 Nylon tie 12 pieces Fixing fiber with protective  coat  3 Heat shrinkable fixing sleeve   3 pieces Fixing and sealing single fiber   for round inlet  cable  4 Heat shrinkable fixing sleeve   1 piece Fixing and sealing single cable   for oval inlet  or mass cables  5 Branching clip 1 piece Branching fiber cables  6 Earthing wire 1 piece Putting through between   Configuration as  earthing devices per requirement  7 Dry agent 1 bag Put into FOSC before sealing  for desiccating air  8 Labeling paper 2 pieces Labeling fibers  9 Special wrench 1 piece Tightening nut of reinforced  core  10   Metal hoop 1 set For wall mounting and pole   Configuration as  hugging per requirement  11   Buffer tube 1 piece Hitched to fibers and fixed  with FOST  managing buffer   12   Aluminum foil paper 1 piece Protect the bottom of Fiber  Optic Splice Closure and cable  inlet outlet tubes when heat the  heat shrinkable sleeves   13   Abrasive paper 1 piece Abrasion of the cable surface  before termoshr
11. stem  which is to be  fixed by hoop fixing bolt then    5 9 4 FOSC installation      Aerial application  fix metal hoop and transom to the pole  Please refer to Drawing 8   2  Wall mounting application  fix the bracket on the wall with bolt   metal hoop is not required       Underground application  metal hoop is not required    5 9 5 See drawing 8    Important issues  1  Pay attention while installing plastic hoop     2  The specification of bolt for fixing the bracket is M8     CY Fiber Optic Splice Closure FOSC SPM037 12 1 12        FOSC cover    Logo    Hoop  metal     Hooplocating bolt    Hoop locking system         4 Transom  metal   Hoop  left     Ci  Zs S  Br t  metal   Irr Base    Meat shrinkable fixing    Pmitry exit tube   sleeve mass     w  Heat s KAOTE TAMIS d  H J    Hoop  right     sleeve single  Branching clip    Iber Cable Fiber cable    CRY    Fiber Optic Splice Closure FOSC SPM037 12 1 12    6  Fiber Optic Splice Closures  FOSC  inspecting and testing items                                        Inspecting type  Inspecting   F Routine test  item Technical Requirements  Before leaving   Type test  factory   Each small package contains one fiber optic splice  Package closure  together with its accessories  tools  installation  manual and packing list   Intact in shape  no burrs  bubbles  chaps  pores  warps  full  Appearance   impurities and other defects  all background colors should  be even and continual   Sign There is a clear sign on the housing  such as
12. vely  To ensure the technical requirements  the following instructions must be followed   5 8 1 Fibers with protective coat are fixed with nylon tie at the entrance of FOST   5 8 2 Grommet should be pressed from inside to outside in order to properly install FOST   5 8 3 Straight through and reserved fibers with protective coat should be winded to the fiber holding  tray   5 8 4 Check whether the internal tighteners and fixing nut of reinforced core are well tightened   5 8 5 Check whether seal fitting is installed neatly and smoothly   5 8 6 Check whether heat shrinkable fixing sleeve is reliable and sealing completely   5 8 7 See Drawing 7   Important issues  If any problems occur  they should be solved right away     CY Fiber Optic Splice Closure FOSC SPM037 12 1 12    Grommet   FOST cover Fiber holding tray   traight through fiber  with protective coat  FOST  Nylon tie  Nylon tie iber wit  protective coat  Fiber with    Fixing device for    protective coat reinforced core       Earthing device       AN  Reinforced core m  ay  Reinforced core    Base G            Bracket  Seal fitting        ol o  eat shrinkable    fixing sleeve mass     l f Branching clip  I  Fiber cable    Fiber cable 3     Heat shrinkable a  fixing sleeve single  i    Fiber cable 1     Drawing 7    5 9 Step Nine     Assemble FOSC housing and fix FOSC   5 9 1 Put desiccant into FOSC    5 9 2 Put FOSC cover on base directly    5 9 3 Install plastic hoop between FOSC cover and base  tighten hoop locking sy
13. y the operators themselves     CY Fiber Optic Splice Closure FOSC SPM037 12 1 12    4  Installation flow chart    1  Open the closure  2  Determine length of fiber cable to be fixed and stripped inside FOSC    3  Strip off protective coats of fiber cable and fiber    4  Separate fiber cores and prepare work prior to fixing fiber cable    5  Fix reinforced core  and pyrocondense  fix and seal fiber cable cable    6  Splice fibers    7  Install heat shrinkable protective sleeve and house fibers    8  Check up comprehensively    9  Assemble FOSC housing and fix FOSC    5  The process of installing FOSC    5 1 Step One   Open the closure  5 1 1 Cleaning the locale and determine where to install the FOSC and then place fiber cables  required     5 1 2 Check whether the main components and accessories have been well prepared inside the     5      CY Fiber Optic Splice Closure FOSC SPM037 12 1 12    package   5 1 3 Open the closure        Demount hoop fixing bolt and pull hoop locking system out  then proceed in demounting  the hoop      Pull the FOSC cover upwards out  installation could begin   5 1 4 See Drawing 1   Important issues  If the weather condition is not good enough  then a tent must be pitched for    waterproof and dustproof     Hoop  left  Hoop  right               Hoop connector    Hoop fixing bolt    FOST    Fixing slote  shrinkable  protective sleeve                 Fixing shelf    for FOST FOSC cover    Grommet    Fixing device for  reinforced core    Seal fitting
    