Operation and installation manual

image

Contents

1. Operation and installation manual SOLIVIA Gateway M1 G2 A NELTA The manual is subject to change Please check our website at www solar inverter com for the most up to date manual version Copyright Delta Energy Systems Germany GmbH All rights reserved This manual accompanies our equipment for use by the end users The technical instructions and illustrations contained in this manual are to be treated as confidential and no part may be reproduced without the prior written permission of Delta Energy Systems Service engineers and end users may not divulge the information contained herein or use this manual for purposes other than those strictly connected with correct use of the equipment All information and specifications are subject to change without notice Operation and installation manual SOLIVIA Gateway M1 G2 1 EN Operation and installation manual SOLIVIA Gateway M1 G2 Table of Contents 1 About this Manual 4 1 1 Purpose of this Manual 4 1 2 Warnings and Symbols 4 2 Intended Use 5 3 General Safety Instructions 5 4 Scope of Delivery 6 5 Planning 6 5 1 Items Tools Required for Installation 6 5 2 Further Requirements 6 6 Connector Positions 7 7 Installation Procedure 8 7 1 Registration 8 7 2 Mounting 8 7 2 1 Mounting on a DIN Rail 8 7 2 2 Mounting Directly to the Wall 9 73 RS485 Connection 9 7 4 Ethernet Connection 9 7 5 Connection of the Ripple Control Receivers 9 7 6 Power Conn
2. the phase except the electrician verifies the cabling of each inverter There is no possibility to check the right mapping of the inverters to Thus the installer should be reminded to put attention to this issue 20 Operation and installation manual SOLIVIA Gateway M1 G2 10 6 2 Balancing The gateway balances the power per phase after every data polling cycle The gateway requests every inverter for the current data After the last inverter of the bus has sent its information the gateway calcuculates the power of each line The gateway calculates the current unbalance The gateway selects the inverters to be power reduced The gateway calculates the reduction factor that is needed to balance the power The gateway sends the power control command to the specific inverters The gateway reduces the power as little as possible This means that the power balanc ing is not reducing the unbalance to 0 kVA a reduction is only needed until the adjusted unbalance limit is adhered 10 7 Inverter Information Login Inverter Information Change Login Data Se Conn Inverter T Serial 9 id lotwork Settings D 1 yes SOLIVIA 3 3 EU G3 113190141151006952 1 yes SOLIVIA 3 3 EU G3 113190141151006948 3 PowerFacor yes SOLIVIASO EU G3 220201111041018352 4 Control yes SOLIVIASO EU G3 220201111041018351 5 Power Balancing yes SOLIVIA 5 0 EU G3 220201111041018364 6 no SOLIVIA30 EU G3 1131
3. There are four binary inputs that control the maximum power the inverter may feed into the grid Log in Power Management Change Login Data Please enter the percentage of nominal power reduction for each input configuration Network Settings j H all inputs are inactive or a value is set to 100 the power is not reduced Power Management Power Factor Control active relaiy closed Power Balancing inactive relay open Inverter Information Inputs Reduction to 4321 of nom power 60 Statistical Info 30 100 0 100 IIe 100 100 o 100 100 DR 100 100 100 100 100 100 Submit Power management is at 100 for all relay state combination except 60 96 for relay 1 30 for relay 2 and 0 for relay 3 default settings 10 5 2 Power Factor Control The power factor configuration page allows the definition of 15 values for the cos either inductive or capacitive If all inputs are inactive the cos is 1 00 The values are entered in the form 0 xx e g 0 95 and a checkbox decides whether it is leading current capacitive or not NOTICE Please remember to save the configurations by pressing the Submit button 1 This chapter is only relevant for countries in which your public grid supplier requires a power reduction power management power factor control and or power balancing 18 Operation and installation manual SOLIVIA G
4. use unbalanced is switched off The other parameters are reset to default DHCP active Proxy not active Wireless RS485 modem not active Unbalanced correction not active Default IPs in subnet 192 168 0 200 Proxy IP 0 0 0 0 Y Default password 000000 and username Delta Inverter list is cleared RRR 22 Operation and installation manual SOLIVIA Gateway M1 G2 2 Keep the reset button pressed gt 20 seconds LED blinks very fast for one second to indicate the reset has been recognized EN All Parameters are reset to their default factory settings i e Y lt lt lt Y Y Y All network settings Baud rate 19200 Interval 15 min Power management is at 100 for all relay state combination except 60 for relay 1 30 96 for relay 2 and 0 for relay 3 Unbalanced load 4 6 kVA Clear all unbalanced configuration Clear all power factor cos phi configuration This reset might require the reconfiguration from your public grid supplier 13 Product Specification RS485 INTERFACE Max in output voltage 20v Output current lt 250 mA Input current lt 42 mA POWER SUPPLY INPUT 5 V DC Max input voltage 8 V Min input voltage 4 V lt 600 mA 3W 5V approx 185 mA Nom input current 1 W Q5 V Max input current AMBIENT CONDITIONS Operating temperature range Davide Storage temperature range Relative humidity 0 96 to 90 96 1 EXT CONTROL ETHERNET IN
5. 10 4 4 Force Gateway Reset To reset the gateway to production settings press either the reset switch for more than EN 5 seconds or click on the Reset button After reset of the gateway the default values shall become used again requiring a new configuration if needed scan starts ending with a flash store The settings of Power Balancing Power Management Power Factor Control Baud rate and send interval remain unchanged All the inverter data are cleared the device is reset and a new RS485 bus 10 4 5 Restart Gateway By pressing the Restart button the gateway will be restarted This restart has no impact on any configurations set before 10 5 Digital Inputs The SOLIVIA gateway gives a voltage to the output A and measures the inputs 1 to 8 In this way the SOLIVIA gateway can detect the state of the relays of the ripple control receivers The information which relay shall control what parameter has to be communi cated by the public grid supplier Example Information from the public grid supplier If relay 2 is closed then the power factor cos shall be set to 0 93 capacitive if relays 1 and 2 are closed then the power factor shall be set to 0 98 inductive If the reactive power control receiver is connected to the SOLIVIA gateway as shown in figure 3 Chapter 7 5 then the Power Factor Control should be configured like in figure 5 Operation and installation manual SOLIVIA Gateway M1 G2 17 10 5 1 Power Management
6. specifications Max conductor cross section 0 5 mm AWG20 Min conductor cross section 0 14 mm AWG26 Tightening torque 0 12 0 15 Nm Max cable length 2 m 10 Operation and installation manual SOLIVIA Gateway M1 G2 7 6 Power Connection Connect the power source to the SOLIVIA gateway Step 3 in figure 4 and check the SOLIVIA gateway LED If the setup is correct the Status LED will be solid green for approx 5 seconds For further information please refer to Chapter 8 Verify that your setup is successful by going to the SOLIVIA Monitor web portal at http Awww solivia monitor com and log in to view your PV system C A SELTA lt Internet RS485 x M Figure 4 Connection diagram Risk of death or heavy injury due to dangerous voltage p Repairs on defective cables should be done by qualified electri cians only gt Only recommended and or commercially available cables should be used 7 7 Installation Feedback NOTICE This function works only for SOLIVIA solar inverters of the 4th generation Operation and installation manual SOLIVIA Gateway M1 G2 11 EN After installation the gateway checks the connection to the Ethernet and to the inverter If the Ethernet connection connection to the internet resp web portal works the gateway sends a message to the inverter The following message a
7. 90141151006959 7 reete information no SOLIVIA 3 0 EU G3 113190141151006956 B no SOLIVIA30 EU G3 113190141151006955 9 no SOLIVIA2 5 EU G3 113190141151006954 10 Statistical Info no SOLIVIA 2 5 EU G3 113190141151006958 11 no SOLIVIA 2 5 EU G3 113190141151006957 12 State of the portal connector Connected State of the gateway Normal operation MAC address 00 18 23 14 00 52 IP address 172 25 21 116 Fw version 1 02 97 Flash save court 71 Value inputs 1 4 0 C Value inputs 5 8 0 y Here you can find the complete list of all SOLIVIA solar inverters that were once detected by the gateway The list contains the following information Connection of the solar inverter gt yes connected gt not connected Inverter type Serial of the SOLIVIA solar inverter ID of the solar inverter Beside these information you can read out the states of the portal connection and of the gateway the MAC and IP address the firmware FW version as well as the count of the flash saves By clicking a serial number you get detailed information about an inverter Operation and installation manual SOLIVIA Gateway M1 G2 21 11 Delta Service Software The Delta Service Software enables the installer to adapt settings realize firmware upgrades and other updates besides supporting him in detecting error sources like e g over or undervoltage without any need to open the inverter The memory from every inverter can be stored and readout wi
8. 999 It is verified that foregoing equipment has been registered under the Clause 3 Article 58 2 of Radio Waves Act WiMonth 30 Date Director General of Radio Research Agency Korea Communications Commission Republic of Korea e 0043221234 vea 21 8 oen po opor gic Ad ape 556 ALA deu Operation and installation manual SOLIVIA Gateway M1 G2 29 30 Operation and installation manual SOLIVIA Gateway M1 G2 SUPPORT EUROPE Austria service oesterreich solar inverter com 0800 291 512 Free Call Belgium support belgium solar inverter com 0800 711 35 Free Call Bulgaria support bulgaria solar inverter com 421 42 4661 333 Czech Republic podpora czechia solar inverter com 800 143 047 Free Call Denmark support danmark solar inverter com 8025 0986 Free Call France support france solar inverter com 0800 919 816 Free Call Germany service deutschland solar inverter com 0800 800 9323 Free Call Greece support greece solar inverter com 49 7641 455 549 Israel support israel solar inverter com 49 7641 455 549 www solar inverter com 28 August 2012 Italy supporto italia solar inverter com 800 787 920 Free Call The Netherlands ondersteuning nederland solar inverter com 0800 022 1104 Free Call Portugal suporte portugal solar inverter com 49 7641 455 549 Slovakia podpora slovensko solar inverter com 0800 005 193 Free Call Slovenia podpora slovenij
9. Rail according to EN60715 TH35 7 5 The gateway should be installed horizontally with connectors on the bottom To mount snap the gateway on the DIN rail as shown in Figure 1 1 Pull the gateway s DIN rail latch OUT 2 Tiltthe unit slightly upwards hook the top end onto the DIN rail and push down wards until stopped 3 Position the bottom front end against the DIN rail until it has snapped onto the DIN rail 4 Push the gateway s DIN rail latch IN to lock C t P on R f yo CA 9 Figure 1 Mounting the gateway on a DIN rail 8 Operation and installation manual SOLIVIA Gateway M1 G2 dismount pull the gateway s DIN rail latch OUT Then tilt the bottom part of the unit out push the unit up and pull out from the DIN rail EN 7 2 2 Mounting Directly to the Wall Mount the gateway with appropriate screws to the wall Use the 2 screws specified in Chapter 5 1 to mount the gateway with the DIN Rail to the wall Center to center distance between the two boreholes is 70 mm Figure 2 Mounting the gateway directly to the wall 7 3 RS485 Connection Connect a standard CAT cable between the RS485 connector on the SOLIVIA gateway and the RS485 connector on the SOLIVIA solar inverter See step 1 in figure 4 below 7 4 Ethernet Connection Connect an Ethernet network cable between the SOLIVIA gateway and the internet connected network point Se
10. Repair work on the device may be carried out by the manufacturer only For a safe and normal operation of the SOLIVIA gateway it is absolutely necessary that the gateway is installed and operated according to this manual see IEC 62109 5 3 3 Delta Energy Systems is not responsible for damage caused by failure to observe the operation and installation instructions in this manual Operation and installation manual SOLIVIA Gateway M1 G2 5 4 Scope of Delivery SOLIVIA Gateway M1 G2 AC power plug 3 adapters for usage in different countries Operation and installation manual Label 5 Planning 5 1 Items Tools Required for Installation Following items and tools are required for installation but are not included to the SOLIVIA gateway box Please make sure to have them available before starting instal lation 1 standard twisted pair Ethernet cable NOTICE The Ethernet cable should meet or exceed the standard CAT5 and should not exceed a length of 100 m These standard twisted pair Ethernet cable can be purchased for your installation at many electronics and office supply retailers The gateway requires a shielded cable STP FTP S FTP or S STP 1 RS485 communication interface cable NOTICE The RS485 cable should meet the protection class IP65 We recommend using the RS485 cable from Harting Part Number 09 45 145 1560 Cable lengths should not exceed 1200 m if Baud rate is 19200 default value The require
11. TERFACE LAN Max in output voltage ao Output current lt 20mA Input current lt 20 mA RIPPLE CONTROL RECEIVER INTERFACE Input voltage ports 1 to 8 pop ors Em GT sev SENE on POWER SUPPLY UNIT PSU voltage range 4Vto8V Max output power 2 W LPS certified Max output tidem gt 600 mA LPS certified 2 Use only the power supply adapter supplied with and suited for the SOLIVIA gateway Operation and installation manual SOLIVIA Gateway M1 G2 23 14 Certificates This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme la norme NMB 003 du Canada This device complies with Part 15 of the FCC Rules Operation is subject to the fol lowing two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Declaration of Conformity According to 47 CFR Parts 2 15 of the FCC Rules and Canada standard ICES 003 Issue 4 For product must be test and Authorized under a Declaration of Conformity Identification of product Basic Gateway Model SOLIVIA GW WEB MONITOR GATEWAY MI G2 This Class B digital device complies with 47 CFR Parts 2 and 15 of the FCC rules and Canada standard ICES 003 Issue 4 Operation is subject to the following two conditions 1 This device may not cause harmful interfere
12. a solar inverter com 421 42 4661 333 Spain soporto espana solar inverter com 900 958 300 Free Call Switzerland support switzerland solar inverter com 0800 838 173 Free Call United Kingdom support uk solar inverter com 0800 051 4281 Free Call Other European countries support europe solar inverter com 49 7641 455 549 A NELTA
13. ateway M1 G2 gt Login Power Factor Control Change Login Data If all inputs are inactive the power factor is 1 Network Settings Connection Settings active relaiy closed Power Management inactive relay open Power Factor Control Power Balancing Inputs Power Leading I D ai 8765 factor current nverter Information capacitive zs 1 00 zs e 1 00 Statistical Info e 100 1 00 1 00 1 00 1 00 s 1 00 ee 1 00 1 00 1 00 e 1 00 1 00 1 00 1 00 Submit Figure 5 Power factor control configuration page 10 6 Power Balancing The German Low Voltage Directive VDE AR N 4105 requires a symmetrical power feed into all three lines of the AC grid The allowed phase unbalance in Germany 4 6 kVA Other countries may have the same or similar requirements Please observe the specific regulations of your country If the power injected into the public grid is not evenly shared over the three phases the gateway is able to balance this unsymmetry 10 6 1 Configuration Following configurations can be set Activate or deactivate the balancing Set the maximum allowed unbalance Assign the single phase inverters to a line L1 L2 L3 1 This chapter is only relevant for countries in which your public grid supplier requires a power reduction power management power factor control and or power balancing Operation an
14. d cable quality is the same as for the Ethernet connection at least shielded STP FTP S FTP or S STP 5 cable or better 2 screws are required to mount the gateway directly to the wall Nominal diameter 4 mm Maximum head diameter 9 mm Maximum height of head 3 mm Screwdriver if gateway should be mounted to the wall size of the screwdriver depends on used screws 5 2 Further Requirements NOTICE The SOLIVIA gateway must be installed only indoors according to protection class IP20 If more than one SOLIVIA solar inverter will be connected in a chain ensure that each inverter has a unique ID assigned in the solar inverter user interface 6 Operation and installation manual SOLIVIA Gateway M1 G2 Please check the SOLIVIA solar inverter manual for instructions on how to select the inverter ID EN The gateway must have an AC power outlet within 2 meters of the gateway NOTICE Please make sure that DHCP is activated at your router so that the IP address of your gateway is automatically found If DHCP is disabled at your router the gateway uses the default IP configuration For further information please refer to Chapter 10 3 6 Connector Positions A DELTA sus G h Status LED 65550505557 800014 GW oo EXT CONTROL RESET RS485 12345678AB t Soo CONNECTOR NAME RESET For detailed information please refer
15. d installation manual SOLIVIA Gateway M1 G2 19 EN Log in Power Balancing Change Login Data Activate correction Network Settings Connection Settings Power Management Allowed unbalanced load Power Factor Control The smaller of the two values will be relevant Power Balancing Inverter Information 2500 absolute maximum in W 100 percentage of nominal power Assign each single phase inverter to a grid line Inverter 111213 SOLIVIA 3 3 EU G3 SOLIVIA 3 3 EU G3 SOLIVIA 5 0 EU G3 e SOLIVIA 5 0 EU G3 SOLIVIA 5 0 EU G3 SOLIVIA 3 0 EU G3 SOLIVIA 3 0 EU G3 SOLIVIA 3 0 EU G3 SOLIVIA 2 5 EU G3 SOLIVIA 2 5 EU G3 SOLIVIA 2 5 EU G3 Submit 10 6 1 1 Feature Activation By default the feature is off For countries without restrictions nothing has to be done 10 6 1 2 Power Balancing Requested from the Public Grid Supplier The default value is 4 6 kVA due to the German regulation This value can be changed to other values without restriction 10 6 1 3 Grid Assignment For each inverter found during the bus scan you can choose to which line L1 L2 or L3 the device is connected NOTICE Please note that the gateway web server will show you a warning if the sum of the nominal powers on the three phases differs by more than the maximum unbalanced load Even with this warning the balancing works However this warning is a strong indication that the mapping of the inverters to the public grid phases should be reviewed carefully
16. e step 2 in figure 4 7 5 Connection of the Ripple Control Receivers You are able to connect the digital inputs to a given function This concerns the control of the power the inverter feeds to the grid ppwer management and of the power factor reactive power control If your local public grid supplier requires a remote power derating capability this can be implemented by using a ripple control receiver Please connect the ripple con trol receiver as shown in figure 3 After the configuration as shown in Chapters 10 5 and 10 6 the public grid supplier is capable to remotely limit the maximum power the SOLIVIA solar inverters provide to the public grid Operation and installation manual SOLIVIA Gateway M1 G2 9 The ripple control receiver that controls the power management power limitation has to be connected to the inputs 1 to 4 The receiver that controls the power factor cos phi has to be connected to the inputs 5 to 8 After connection of the ripple control receiver s the gateway has to be configured in order to do the required control of the SOLIVIA solar inverters For further information please refer to Chapters 10 5 and 10 6 Of course it is also possible to connect only one ripple control receiver i e the one that controls the power management Figure 3 Ripple control receivers circuit diagram NOTICE The cables connecting the SOLIVIA gateway with the ripple control receiver s should meet the following
17. ection 11 7 7 Installation Feedback 11 8 LED Status 12 9 Troubleshooting RS485 Ethernet Communication 12 10 Configuration through Web Server 12 10 1 Access the Configuration Web Server 13 10 2 First Log in 14 10 3 Network Settings 14 10 4 Connection Settings 15 10 4 1 RS485 Bus Communication 16 10 4 1 1 Wireless RS485 Modem 16 10 4 2 Delta Database Connection 16 10 4 3 Force RS485 Bus Scan 16 10 4 3 1 List of Connected SOLIVIA Solar Inverters 16 10 4 4 Force Gateway Reset 17 10 4 5 Restart Gateway 17 10 5 Digital Inputs 17 10 5 1 Power Management 18 10 5 2 Power Factor Control 18 10 6 Power Balancing 19 10 6 1 Configuration 19 10 6 1 1 Feature Activation 20 10 6 1 2 Power Balancing Requested from the Public Grid Supplier 20 10 6 1 3 Grid Assignment 20 10 6 2 Balancing 21 10 7 Inverter Information 21 11 Delta Service Software 22 12 Reset Button 22 13 Product Specification 23 14 Certificates 24 Operation and installation manual SOLIVIA Gateway M1 G2 3 EN 1 About this Manual Congratulations on the purchase of the SOLIVIA Gateway M1 G2 These directions will help you become familiar with this product Please observe the safety regulations of the individual countries Careful handling of your product will con tribute to its service life durability and reliability 1 1 Purpose of this Manual This manual is part of the product and is only valid for the SOLIVIA Gateway M1 G2 Keep this manual in a safe place Read t
18. ennspannungen DC 5V Rated Voltages Nennstr ne 1 185mA Rated Currents Umgebungatewperatur 40 C max Ambient Temperature Schutzklasse 1 III Protection Class Fortsetzung Blatt continued on page 0002 10 ANLAGE Appendix 1 Eege Fer ir e n C 2 ee on me SSC e e open Reguistion Prodivct rr y ton F T V Rheinland LGA Products GmbH 2 90431 N rnberg x Ta 449221 06 13 71 email cert vali Fax 492215 06 39 35 ipe a ar tet Dipl Ing A Zimmer Ausstcllungsdatum Date of Issue 21 02 2012 day mo yr 26 Operation and installation manual SOLIVIA Gateway M1 G2 IEC aA IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST SYSTEME CEI D ACCEPTATION MUTUELLE DE CERTIFICATES FOR ELECTRICAL EQUIPMENT CERTIFICATS D ESSAIS DES EQUIPEMENTS IECEE CB SCHEME ELECTRIQUES IECEE METHODE OC CB TEST CERTIFICATE CERTIFICAT D ESSAI OC Product Produit Basic Gateway Name send ackteess of the applicant Elegy Pu Public Ltd Nom et adresse du dernamceur Sot GER pe 2 Patsa Phraksa Amphur Muang Name and ad ross of the manufacturer Delta Electronics Public Co Ltd Nom et adresse du fabricant o 4 ae LK Phraksa Amphur Muang Nanse and adress of the factory Soo addsional page s et adressa de l usine Input DC 6V 185mA Class Reting and principal charactoristics Valeurs noeninales et caract risti
19. es to the database Here you can define the intervals in minutes of how often the average values and parameters are sent to the database By default 15 minutes is set 10 4 3 Force RS485 Bus Scan The gateway does not know the number and addresses of connected inverters in advance It is assumed that each inverter connected to the bus already has its unique address in the range 1 254 Address 0 is not allowed and 255 is the value used for broadcasts NOTICE Please check the SOLIVIA inverter user manual for instructions on how to select the inverter ID Usually the list of inverters gets only longer Every inverter that was once detected by the gateway will remain in this list By pressing the Start button the list will be can celled and the RS485 bus will be scanned for connected inverters The gateway is designed to connect to a maximum of 32 devices 10 4 3 1 List of Connected SOLIVIA Solar Inverters At power up start up and each day at about noon the gateway scans the RS485 bus for all connected SOLIVIA solar inverters Start from address 1 up to address 254 Address 0 is invalid and address 255 is the broadcast address During the usual operation the gateway collects only the data of the inverters in the inverter list If a new inverter is connected at e g 2 00 pm this inverter will only be re cognized after a new scan latest the next day at about noon 16 Operation and installation manual SOLIVIA Gateway M1 G2
20. his manual carefully and follow the instructions given in this manual This manual contains important information for installing and operating the gateway Observe and follow the information for safe use please refer to Chapter 3 Both the installer and the operator must have access to this manual and must be famil iar with the safety instructions 1 2 Warnings and Symbols Here you will find explanations for the warnings and symbols used in this manual Indicates a hazardous situation If not prevented an accident will result in death or serious injury to humans DANGER Indicates a hazardous situation If not prevented an acci dent could result in death or serious injury to humans Indicates a hazardous situation If not prevented an acci dent could result in moderate or minor injury to humans NOTICE Indicates a hazardous situation that could result in pro perty damage This symbol warns of the dangers of electric shock due to high electrical voltage This symbol warns against a general danger l Operation and installation manual SOLIVIA Gateway M1 G2 In order to avoid damage to property or personal injury m only qualified trained electricians may work on the equip EN ment The qualified electrician must familiarise himself herself with this manual Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for infor
21. ial Estate E P Z Pattana 1 Rd Tambol Phraksa Amphur Muang Samutprakarn 10280 Thailand ie e HEREBY CERTIFY THAT SPORTON LAG EN d THE MEASUREMENTS SHOWN IN THIS TEST REPORT WERE MADE IN ACCORDANCE WITH THE PROCEDURES GIVEN IN EUROPEAN COUNCIL DIRECTIVE 2004 108 EC THE EQUIPMENT WAS PASSED THE TEST PERFORMED ACCORDING TO European Standard EN 55022 2010 Class B CISPR 22 2008 Class B CISPR 11 2003 A1 2004 A2 2006 Class B EN 61000 3 2 2006 A2 2009 EN 61000 3 3 2008 EN 55024 2010 and CISPR 24 2010 IEC 61000 4 2 2008 ED 2 0 IEC 61000 4 3 2010 ED 3 2 IEC 61000 4 4 2010 ED 2 1 IEC 61000 4 5 2005 ED 2 0 IEC 61000 4 6 2008 ED 3 0 IEC 61000 4 8 2009 ED 2 0 IEC 61000 4 11 2004 ED 2 0 and Australian Standard ASINZS CISPR 22 2009 Class B THE TEST WAS CARRIED OUT 06 2012 AT SPORTON INTERNATIONAL INC LAB Alex Chen Dept Director gt SPORTON INTERNATIONAL INC 6F No 106 Sec 1 Hsin Tai Wu Rd Hsi Chih Taipei Hsien Taiwan R 28 Operation and installation manual SOLIVIA Gateway M1 G2 E3E3 2FBC 48C4 D97E d 947 1493 AFEEF US SOLIVIA GW WEB MONITOR GATEWAY M1 G2 aui Jeanne Resbrsiba Mb KCC REM DTE SOLIVIAGWM1G2 DELTA ELECTRONICS THAILAND PUBLIC CO LTD 43 AZAZ Y7 Manufacturer Country of Origin 2 numi eee 7 Others A45 EH 7EDelta Electronics Power Dongguan Co Ltd AAAS AMM 2158292 213999 Het 599989 29
22. ings on the left side to open the following window where you can enter your network parameters 14 Operation and installation manual SOLIVIA Gateway M1 G2 Log in Network Settings Change Login Data Use DHCP to get an IP address Network Settings Connection Settings Use Proxy Power Management Power Factor 0 0 0 0 IP of Proxy Control Power Balancing 192 16 0200 IP address 255 255 255 0 Subnet mask Statistical info 192 16 0 1 Network gateway address 192 168 021 IP of ONS server Submit NOTICE By default the gateway is configured to get its IP address from a DHCP server To confirm your entering click the Submit button 10 4 Connection Settings Login Change Login Network Settings Connection Settings Operation and installation manual SOLIVIA Gateway M1 G2 15 10 41 RS485 Bus Communication Here you can set the baud rate of the gateway for the 5485 communication The value should match the one of the inverter s The baud rate 19200 is set by default NOTICE Please note that the RS485 cable lengths is depending on the baud rate Cable lengths should not exceed 1200 m if baud rate is 19200 default value 10 4 1 1 Wireless RS485 Modem If you are using a RS485 wireless modem please check the box 10 4 2 Delta Database Connection Every few seconds the gateway is retrieving data from the SOLIVIA solar inverters The gateway stores these data and sends the average valu
23. mation regarding the collection systems available If electrical appliances Kwasasa are disposed of in landfills or dumps hazardous sub stances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old appliance for dis posal at least for free of charge 2 Intended Use The SOLIVIA gateway is the interface between your SOLIVIA inverter and the SOLIVIA Monitor web portal It transmits all relevant data from your SOLIVIA inverter for exam ple the supplied AC energy of the day the actual AC power some error bytes etc to the SOLIVIA Monitor web portal It allows you continuous monitoring of your PV system from anywhere that you have internet access The SOLIVIA gateway must be used indoors with IP20 environmental conditions The SOLIVIA gateway must only be operated according to its intended use 3 General Safety Instructions Please observe the safety regulations of the individual countries Careful handling of your product will contribute to its service life durability and reliability These are essen tial pre requisites for maximum yield from your product Inappropriate handling can lead to physical injury and material damage Do not remove warning labels that have been attached to the SOLIVIA gateway by the manufacturer Observe all points in this installation and operation manual
24. nce and 2 this device must accept any interference received including interference that may cause undesired operation Manufacturer Importer information Delta Products Corporation Company name 4405 Cushing Parkway Fremont CA 94538 Address 510 668 5100 Telephone No and was made by Graham Hunter Surname forename Vice President of Sales Power Supplies Position in manufacturer s company th Eb Fremont March 9 2012 d City Date Legally valid signature C WORD DOC 990416 24 Operation and installation manual SOLIVIA Gateway M1 G2 Sing Etac Services Pty Ltd ABN 941339000008 33 Mackeller Avenue Wheelers Hill Vic 3150 Australia Phone 61 3 95451418 Fax 61 3 95451418 Ref 4 I2CTICK001 C Tick Mark Conformity Declaration For the following equipment Basic Gateway Model Name SOLIVIA GW WEB MONITOR GATEWAY MI G2 Model Designation Herewith is confirmed to comply with the requirements set out in the regulation to Electromagnetic Compatibility For the evaluation regarding the electromagnetic compatibility the following standards were applied AS NZS CISPR 22 amp CISPR 11 The following manufacturer is responsible for this declaration Company name Delta Electronics Thailand Public Co Ltd Address 909 Soi 9 Moo 4 Bangpoo Industrial Estate E P Z Pattana 1 Rd Tambol Phraksa Amphur Muang Samutprakarn 10280 THAILAND The f
25. ollowing importer is responsible for this declaration Company name Sing Etac Services Pty Ltd Address 33 Mackeller Avenue Wheelers Hill Vic 3150 Australia Person responsible for making this declaration Christina Chen Sok Kian Name Director Position Title e ex Sk March 9 2012 Date Legal Signature Operation and installation manual SOLIVIA Gateway M1 G2 25 EN Zertifikat Certificate e TUVRheinland Zertifikat Nr Certificate No Blatt Page d 8 50222664 0001 the Zeichen Client Reference Unser Zeichen Our Reference Liingstens g ltig bis Latest ue dote 1203011191 ZTH1 soj 19005769 001 20 02 2017 Genehmigungsinhaber License Holder Fertigungsstatte Manufacturing Plant Delta Electronics Thailand Public Delta Electronics Thailand Public Co Ltd Co Ltd 909 Soi 9 Moo 4 Bangpoo Industrial 909 Soi 9 Moo 4 Bangpoo Industrial Estate E P Z Pattana 1 Rd Estate 2 Pattana 1 Rd Tambol Phraksa Amphur Muang Tambol Phraksa Amphur Muang Samutprakarn 10280 Samutprakarn 10280 Thailand Thailand Pr fzeichen en Test Mark Gepr ft nach Tested to 7 EN 60950 1 2006 11 1 12 ZEK 01 4 08 11 11 Zer fiziertes Produkt Ger teidentifikation Lizenzentgelte Einheit Certified Product Product Identification License Fee Unit Datenverarbeitungs Ger t Basic Gateway Bezeichnung SOLIVIA GW WEB MONITOR GATEWAY 1 G2 10 Type Designation N
26. ppears on the display of the inverter Portal Connection ok If the Ethernet connection is not working the following message appears on the display of the inverter No Portal Connection Both messages will be displayed for 120 sec If the message No Portal Connection appears on the display please check the Ether net connection of the gateway and your internet connection If no message appears on the display please check the RS485 connection between gateway and inverter and ensure that all inverters have unique RS485 bus IDs 8 LED Status The gateway has one single LED visible on top of the housing of the gateway After power up it immediately starts scanning for connected inverters So the LED is con stantly ON no blinking until the scan is finished After that the LED change to one of the following behaviors COLOR AND CONDITION Constantly ON no blinking Neither Ethernet nor inverter connection Fast blinking 300 ms Ethernet connection but no inverter connection Slow blinking 1 s No Ethernet connection but inverter connection Hinking 200 ms on Ethernet as well as inverter connection is online 1800 ms off Indicates for one second that the reset button has been Extremely fast blinking pressed 9 Troubleshooting RS485 Ethernet Communication If one connection Ethernet or RS485 works try to exchange the cables If now the other interface works it is very likely that one cable is broken 10 Configu
27. ques principales Trademark of DELTA ELECTRONICS INC Trade mark any Marque de fabrique si elle existe SOLIVIA GW WEB MONITOR GATEWAY M1 G2 Modol type Ret Bei de type Adicional information necessary Testing location TMP Inca mation compl montavo s n cessairo sample of the product was tented and feed IEC 00950 1 2005 A bo be in condo rity with National differences see test t Un chant ion de ce produ a 44 nssry et a p consid r coe orene 1 As shom in the Test Report Bel No which foems part 19005768 001 of this Centilicmto Comens indiqu dans le Rapport d essais num ro de e t rence qui consthse une parte de Cortificat This CB Test Certificate bs issued by the National Certification Body Co Cortificst dessai OC tabli pes l Organisme National de Certification T V Rheleland Japan Ltd n 1 Globe Technology Assessment Center A TUVRheinland Yokohama 224 0021 Japan Phono 8t 45 014 3888 Fax 814501463054 Pd Mait info ipo tux com Wolk eng Ire com Dato 21 02 2012 Signature Dipl Ing A Zimmer KIC JPTUV 042448 Operation and installation manual SOLIVIA Gateway M1 G2 27 SPORTON LAB Certificate No EC221006 CERTIFICATE EQUIPMENT Basic Gateway MODEL NO SOLIVIA GW WEB MONITOR GATEWAY M1 G2 APPLICANT Delta Electronics Thailand Public Co Ltd 909 Soi 9 Moo 4 Bangpoo Industr
28. ration through Web Server The HTTP server implements a browser interface allowing you to configure the gateway and to display several information The features are Log in Configuration Display information about inverters 12 Operation and installation manual SOLIVIA Gateway M1 G2 10 1 Access the Configuration Web Server To access the configuration tool you have to install the software program EN IP Resolver that you can download from our website www solar inverter com NOTICE Please make sure that your internet connection is active Once installed start the program by double click The following window will open EET 172 25 161 87 00 8 273 14 00 31 172 25 061 99 00 10 22 14 00 50 172 25 161 72 00 18 23 18 02 LF mem s In case that the IP address is not immediately found click on the rescan button Then double click on the IP address in the IP Resolver to open the web server The log in window will open A NELTA Login Please log in Change Login User name Network Sezings Connection Settings Pose Managemen Factor Contro Power Balancing ge Passwort inverter Information Dags info If your network do not work with DHCP please proceed as follows 1 Configure your computer settings manually to 192 168 0 199 2 Open your web browser 3 Insert IP http 192 168 0 200 4 Now go to Chapter 10 3 to see how you configure the IP of
29. th the software in order to facilitate maintenance and on site service Detailed information of every inverter can be monitored and if nec essary adapted The SOLIVIA gateway replaces the service software kit that consists out of a Delta RS485 special cable and a USB to RS485 converter Therefore beside the gateway and the software itself which can be downloaded from our website free of charge no further equipment nor tools are necessary Proceed as follows 1 Connect a RS485 cable between the RS485 connector on the SOLIVIA gateway and the RS485 connector on the SOLIVIA inverter 2 Connect an Ethernet network cable between the SOLIVIA gateway and the internet ready network port 3 Donwload the software from our website free of charge 4 Start the service software program NOTICE Please make sure that your internet connection is active For further information about the SOLIVIA service software please refer to our website at www solar inverter com 12 Reset Button The reset button offers two different functionalities Please also refer to Chapter 10 for further information on the below mentioned configuration parameters 1 Keep the reset button pressed gt 5 seconds and lt 20 seconds gt LED blinks very fast for one second to indicate the reset has been recognized Does a soft reset of the configuration parameters Baud rate interval time power management and unbalanced settings are not changed except that
30. the SOLIVIA gateway Operation and installation manual SOLIVIA Gateway M1 G2 13 10 2 First Log in If you log in to the configuration web server for the first time please enter the following log in data Default Username Delta Default Password 000000 Then click the Log in button NOTICE If you leave the server untouched for more than five minutes it is logged out automati cally and any access will provide the log in page As you log in for the first time you will be asked to change your log in data for security reasons The following window will automatically open Login Change Login Data press sumer to bypaes Change Login Data The following constraints apply Network Settings Connecton Settings e max 12 and min 2 figures for user name Power Management max 12 and min 6 figures for password Power Factor Control e the password contain letters a 2 Z digits 0 9 and underscore Power Balencing you must use upper and lower case letters and at least one digit Inverter Information User name Sttsticat Info Change your log in data by following the instructions given and click on the Submit button After submitting your new data the following message will confirm your changes Operation successfully completed 10 3 Network Settings If your router is not supporting DHCP you will have to enter the IP address of your SOLIVIA gateway manually Click on Network Sett
31. to Chapter 7 8 RS485 Connection of your SOLIVIA inverter with the SOLIVIA gateway EXT CONTROL Ripple control receivers control the power management power limitation and the power factor cos 9 Connection of your SOLIVIA gateway with an internet connected LAN network point INPUT 5V Gateway power supply connector Operation and installation manual SOLIVIA Gateway M1 G2 7 7 Installation Procedure 7 1 Registration First register for a SOLIVIA Monitor user account on the web at http register solivia monitor com After registering you will receive via email a user name a password and a link to a Configuration Wizard that will allow you to set up and monitor your site from the SOLIVIA Monitor web portal Complete the Configuration Wizard setup before installing the monitoring hardware In this way you can go to the web portal after the hardware installation and verify everything is working correctly NOTICE At the install site verify the internet connection is active by connecting a laptop to the internet connected network point and pointing a web browser to www solar inverter com 7 2 Mounting Mount the SOLIVIA gateway with the appropriate AC power location specified in Chap ter 5 2 You have either the possibility to mount the SOLIVIA gateway on a DIN rail or directly to the wall 7 2 1 Mounting on a DIN Rail The gateway can be mounted on the following DIN Rails DIN Rail according to EN60715 TH35 15 DIN