1. 099000800000 00000000 90000000 0000000006 0000000900 92001000 aooonoou fnogauangognouaans 1000000000090000006 27 3 5 System Fan The 4U60L series chassis supports hot swappable system fans Replacing the System Fan remove the top cover from the chassis See p 16 for more gt Before replaceing the system fan details Front Fan Module Push back the release latch at the top of the front fan 2 While holding the latch back in the unlocked position pull the fan up and out towards 1 you Release the latch after the fan has been removed 28 Middle Fan Module 1 Press and hold the clip on the middle fan 2 Lift the system fan away from the chassis 1U60L Series 30 3 6 Motherboard Attention DO NOT open the motherboard tray if the server is not powered down or while it is still running Replacing the Motherboard You must remove all connected cables from the motherboard to avoid damaging the motherboard and its components when you remove it later Release the thumb screw on the tray if it is tightened Pull the motherboard node tray handle downward Slide back the motherboard node tray Carefully slide the tray completely out of the chassis EE r ce Remove the screws that secure the motherboard to the node tray Lift to remove the motherboard 6 Reverse the procedure to install a motherboard AU60L Series
2. Motherboard Configurations MB2 MB1 MB2 MB1 MB1 DBH DBZ DBJ DB DBH DBZ DBJ EXPB1 EXPB EXPB EXPB EXPB2 EXPB EXPBZ N A a MBI MB2 MBI MB2 MBI MB2 V V V V V N A 60 idle HDD 30 30 60 N A idle 60 HA High Availability Mode Nodel and Node2 support 60 SAS HDDs When one of the nodes operates normally the other node idles If an unexpected error crash or shutdown occurs on the operating node the idle node then takes over the job To support HA you need to install both motherboard 1 in Nodel and motherboard 2 in Node 2 and change your daughter board to DBH Zoning Mode Each node runs the job individaully Each node supports 30 SAS or SATA HDDs To support Zoning you need to install both motherboard 1 in Nodel and motherboard 2 in Node 2 and change your daughter board to DBZ Single Node Mode Only Nodel supports 60 SAS or SATA HDDs Node is not functioning To support Single Node you only need to install motherboard 1 in Nodel and change your daughter board to DBJ To know more about how to change a daughter board refer to the section entitled 3 7 Daughter Board A Refer to the user manual of the motherboard you use for instructions on how to install motherboard components 34 3 7 Daughter Board Replacing the Daughter Board Depending on the HA mode Zoning mode or Single Node mode you require for your system install the compatible daughter board for proper function
3. 3 Place the 2 5 HDD into the carrier with the label facing up and the connector end toward the rear of the carrier Carefully align the mounting holes in the hard drive and the carrier Secure the hard drive using the four screws Place the hard drive carrier back to into the chassis AU60L Series Installing a Hard Drive Carrier into the Chassis 1 Gently slide the HDD carrier into the chassis evenly 2 Push the carrier downwards until it is firmly seated and locks into place 23 24 3 3 Power Supply The 4U60L Series can accommodate four CRPS Common Redundant Power Supplies power supplies in the bay at the rear of the chassis Each unit provides up to 800 Watts of power Three power supplies are required for operation with the other power supply purely as a redundant load sharing backup It can be removed without affecting system operation Before replacing the power supply power off the server unplug the power cord and discon nect all wiring from the power supply Installing and Removing the Power Supply Installing the Power Supply Unit 1 Align the power supply unit with the power supply slot Ensure that the LED appears on the lower right when you are installing the power supply unit 2 Carefully slide the PSU all the way into the power supply bay until it clicks into place AU60L Series Removing the Power Supply Unit To remove a failed power supply identify the
4. 7 Replace the top cover 34 4U60L Series Appendix A Installing the CPU 1 Before you insert the 1150 Pin CPU into the socket please check if the PnP cap is on the socket if the CPU surface is unclean or if there are any bent pins in the socket Do not force to insert the CPU into the socket if above situation is found Otherwise the CPU will be seriously dam aged 2 Unplug all power cables before installing the CPU 35 Installing the CPU Fan and Heatsink 4U60L Series A Before you installed the heatsink you need to spray thermal interface material between the CPU and the heatsink to improve heat dissipation 37 Installation of Memory Modules DIMM The DIMM only fits in one correct orientation It will cause permanent damage to the motherboard and the DIMM if you force the DIMM into the slot at incorrect orientation For more information about DIMM installation please refer to the User Manual that comes with the serverboard you use 38 4U60L Series Appendix B Installing the Server in a Rack This section describes how to rackmount the server with slide rail assemblies 1 The rails installation instructions in this manual are example only your actual rail SY assembly procedure may differ slightly 2 Please purchase the rail assembly seperately if needed The slide rail assembly consists of a chassis rail and a slide rail You need to attach the chassis rails to the
5. a reliable barebone system produced under ASRockRack s consistently stringent quality control It delivers excellent performance with robust design conforming to ASRockRack s commitment to quality and endurance Because the hardware specifications might be updated the content of this documentation will be subject to change without notice In case any modifications of this documentation occur the updated version will be available on ASRockRack s website without further notice If you require technical support related to this product please visit our website for specific information about the model you are using ASRockRack s Website www ASRockRack com DA The illustrations shown in this manual are examples only the actual system may differ slightly 1 1 System Package Contents The system can be configured to operate in three different modes HA High Availability Zoning and Single Node JBOD Please refer to the table below for the required components for each mode Z 4U60L Series Barebone 4U form factor Motherboards MB Expander Board EXPB Expander Board EXPBZ HA Daughter Board DBH Zoning Daughter Board DBZ Single Node Daughter Board DBJ Right Power Distribution Board RPDB Left Power Distribution Board LPDB Middle Plane Board MPB 3 5 2 5 HDD Back Plane Board BPB 2 5 HDD Back Plane Board BPB Front Panel Board FPB Power Supply Units System Fans Accesso
6. can change the Daughter Board DBH DBZ DB J to support different modes and toggle among HA Zoning or Single Node Node 2 doesn t support Single Node function For more information please refer to 3 6 Mother board Configurations 7 12 2 3 System Front Panel Ln OR WwW N o o o o 0090000000 900990000 999900000 fey 09000006000 90000060000 go 0000000000000 000 000000000000000 O 000 000000000000000 G 1900 000000000000000 G 000 000000000000000 000 000000000000000 G 000 000000000000000 G 000 000000000000000 O 000 000000000000000 G 1900 000000000000 O OO 000000000000 O 2 2 090000000000 2 Control Panel Buttons and LEDs Left for Node 1 2 x USB 2 0 Ports Left for Node 1 5 x HDD Backplane Trays 2 x USB 2 0 Ports Right for Node 2 Control Panel Buttons and LEDs Right for Node 2 2 4 System Rear Panel 10 11 12 WARNING Do NOT open the trays if the server is not powered down or while it is still running 000000000000000200000 000000000000000200000 G00000000000000P00000 000000 00 Di 00 a el ei v00000000 0000000000808 20
7. the mounting holes you selected on the rack Add a washer between the screw and the cabinet rail Tighten the screw to secure the slide rails to the rack Washer a lt 4 9 e Na je lt pe az BERG Z i 7 FFT X EN EY 43 44 Sliding the Server into the Rack 1 Ensure that the slide rails are properly and securely attached to the rack 2 Fully extend the slide rails from the rack by pulling the inner rails out until they are locked and cannot be pulled out further DEBR HOG Y DER DOTE 4U60L Series 3 Slide the release tabs on both sides and slide the server slowly and evenly all the way into the cabinet to ensure that the slide assemblies are working correctly The server is heavy For safe lifting two or more persons are required to install the server into the rack Release Tab 45 4 Tighten the two thumb screws on the front of the server to secure the server to the rack 5 To remove the server from the rack reverse these instructions When connecting cables to the server make sure there is enough cable slack so you can slide the server in and out of the rack without accidentally unplugging a cable Optional Accessory Please purchase the following optional accessory seperately if needed Rail Assembly Kit Model Name KINGSLIDE AR60 940 46
8. 09000000 G00000000 0000000 0000000 00 0000000 5999 ooo 000 000 000 000 000000000000000000 O00 G 0000000000000 000000000000000000 00000000 a fe G el Q G fe G el Q fe fe fe fe Q fe fe 00000000000000000 00000000 00000000 00000000 000000000000000000000 el 0000000000000000000 Add on Card Slot MB2 Supports Low profile and FHHL Full High Half Length add on cards When the PCIE1 slot on the E3C224D4HM 8R motherboard is populated the LSI SAS connec tors will be disabled I O Shield depends on the specification of the motherboard MB2 2 5 HDD trays MB2 Motherboard Node Tray Handle Node2 WARNING Please do NOT open the tray if the server is not powered down or while it is still running Mezzanine Card Support for 1GbE x 2 10GbE x2 or SFP Fiber x2 MB2 Rear Vent Add on Card Slot MB1 Supports Low profile and FHHL Full High Half Length add on cards When the PCIE slot on the E3C224D4HM 8R motherboard is populated the LSI SAS connec tors will be disabled I O Shield depends on the specification of the motherboard MB1 2 5 HDD trays MB1 Motherboard Node Tray Handle Nodel WARNING Please do NOT open the tray if the server is not powered down or while it is still running Mezzanine Card Support for 1GbE x 2 10GbE x2 or SFP Fiber x2 MB1 4 x Power Supply Units To configure an a
9. 3 Fan3 error 13 BPB4 HDD Link Blinking Green HDD36 HDD47 active and accessing 14 BPB4 HDD Error Solid Red BPB4 HDD error 15 BPB4 PWR Error Solid Amber BPB4 power error 16 BPB4FAN Error Solid Amber BPB4 Fan4 error 17 BPB5 HDD Link Blinking Green HDD48 HDD59 active and accessing 18 BPB5 HDD Error Solid Red BPB5 HDD error 19 BPB5 PWR Error Solid Amber BPB5 power error 20 BPB5 FAN Error Solid Amber BPB5 Fans error Please refer to the 2 1 System Components p 5 for the locations and numbering ofthe hard drives AU60L Series Chapter 3 Hardware Installation and Maintenance This chapter helps you assemble the chassis and install components Before You Begin Before you work with the server pay close attention to the Important Safety Instructions at the beginning of this manual 1 Make sure the server is powered off Power down the server if it is still running 1 Press the Power button to power off the server from full power mode to power off mode The Power LED at the front turns from solid green to off 2 Disconnect the power cord first from the AC outlet and then from the server The power LED turns off The server is not completely powered down when you press the Power button on the front panel Some internal circuitry remain active in the Power off mode To remove all power from the system completely be sure to disconnect the power cord from the server 2 Ensure you have a clean and s
10. 4U60L Series User Manual Version 1 0 Published June 2015 Copyright 2015 ASRock Rack INC All rights reserved Version 1 0 Published June 2015 Copyright 2015 All rights reserved Copyright Notice No part of this documentation may be reproduced transcribed transmitted or translated in any language in any form or by any means except duplication of documentation by the purchaser for backup purpose without written consent of us Products and corporate names appearing in this documentation may or may not be registered trademarks or copyrights of their respective companies and are used only for identification or explanation and to the owners benefit without intent to infringe Disclaimer Specifications and information contained in this documentation are furnished for informational use only and subject to change without notice and should not be constructed as a commitment by us We assumes no responsibility for any errors or omissions that may appear in this documentation With respect to the contents of this documentation we do not provide warranty of any kind either expressed or implied including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose In no event shall we our directors officers employees or agents be liable for any indirect special incidental or consequential damages including damages for loss of profits loss of business loss of data int
11. ality DBH DBZ DBJ CONT CON3 CONT CON3 CON1 CON3 Red 4U60L DBH ASRek 4U60L DBZ neh 4U60L DBJ CON2 CON4 CON2 Cond Before replacing a daughter board you must power down the system completely 1 Remove the top cover For more details please refer to the section entitled 3 1 Server Top Cover 2 Remove the screws that secure the daughter board bracket to the chassis Remove the daughter board bracket and set it aside for re assembly 32 3 Gently and vertically lift up and remove the daughter board from the Expander Board EXPB 4 Correctly orientate the daughter board you need When facing the rear of the chassis the CONI on the daughter board you are about to install should be at the right bottom corner CON1 Node2 Node1 MB2 MB1 1 The daughter board must be lift up or installed vertically Installing the daughter board incorrrectly may cuase irreparable damage to the connector pins 2 When you change the daughter board to switch among different system modes do not forget to change the relavant cable connections as you need 33 5 Align the connectors on the daughter board with the Expander Board card connectors Vertically install the daughter board to the the Expander Board card with a little pressure 6 Then install the daughter board bracket back to the chassis with screws
12. ddle System Fan Fan Failed LED Fan LED Status Description Solid Amber Fan failed Off Normal To know the status of the front system fans please check the Fan LED indicators on the corresponding backplane boards 13 14 2 9 Backplane LEDs 00000 00000 TE 09000 22000 00090 00000 00000 00 000 00 00 000 e 00 00 d 200 p 00 00 ft Gao TH o 388 8 co 88 900 Py o ao 588 22 SEE PAIE ES PAIE ESS 00060000 2 8 0000 28 o006o00 828 W 000 90009 9 28 000 a hfaa a DG 600 a 60 000 a 00 BPB1 BPB2 BPB3 BPB4 BPB5 1333 132 P 1 BPB1 HDD Activity Blinking Green HDDO HDDII active and accessing 2 BPB1 HDD Error Solid Red BPB1 HDD error 3 BPBI PWR Error Solid Amber BPB1 power error 4 BPB1 FAN Error Solid Amber BPB1 Fanl error 5 BPB2 HDD Activity Blinking Green HDD12 HDD23 active and accessing 6 BPB2 HDD Error Solid Red BPB2 HDD error 7 BPB2 PWR Error Solid Amber BPB2 power error 8 BPB2 FAN Error Solid Amber BPB2 Fan error 9 BPB3 HDD Link Blinking Green HDD24 HDD35 active and accessing 10 BPB3 HDD Error Solid Red BPB3 HDD error 11 BPB3 PWR Error Solid Amber BPB3 power error 12 BPB3 FAN Error Solid Amber BPB
13. erruption of business and the like even if we have been advised of the possibility of such damages arising from any defect or error in the documentation or product FE This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CALIFORNIA USA ONLY The Lithium battery adopted on this motherboard contains Perchlorate a toxic substance controlled in Perchlorate Best Management Practices BMP regulations passed by the California Legislature When you discard the Lithium battery in California USA please follow the related regulations in advance Perchlorate Material special handling may apply see www dtsc ca gov hazardouswaste perchlorate Important Safety Instructions Pay close attention to the following safety instructions before performing any of the operation Basic safety precautions should be followed to protect yourself from harm and the product from damage Operation of the product should be carried out by suitably trained qualified and certified personnel only to avoid risk of injury from electrical shock or energy hazard Disconnect the power cord from the wall outlet when installing or removing main system components such as the motherboard and power supply unit Place the system on a stable a
14. failed power supply by checking the power supply LEDs on the PSU Hold onto the power supply handle while pressing the locking lever towards the power i supply handle 2 Pullto remove the power supply from the chassis 1 Before replacing the power supply power off the server unplug the power cord and disconnect all wiring from the power supply 2 Ina redundant system you do not need to power down the server 25 26 3 4 Add on Card Before installing the add on card power off the server and unplug the power cord Installing the Add on Card in the Chassis 1 Remove the screw securing the cover in place for each low profile add on slot you want to use Keep this screw for later use a 2 Align the add on card and insert into place 3 Secure each card to the chassis using the screw previously removed 1 You can install an add on card to the chassis only when you have a riser card installed on the motherboard 2 Before installing the add on card power off the server and unplug the power cord AU60L Series Removing the Blanking Plate for a LAN Mezzanine Card You can use an optional Ethernet mezzanine card for additional LAN ports Please be aware that the mezzanine card must be used in conjunction with a matching I O module Remove the two screws that secure the blanking plate on the chassis Keep this screw for later use
15. nd flat surface Use extreme caution when working with high voltage components When handling parts use a grounded wrist strap designed to prevent static discharge Keep the area around the system clean and clutter free Keep all components and printed circuit boards PCBs in their antistatic bags when not in use Handle a board by its edges only do not touch its components peripheral chips memory modules or contacts Contents Chapter 1 Introduction 1 1 1 2 System Package Contents Specifications Chapter 2 Server System Overview 2 1 2 2 2 3 24 2 5 2 6 2 7 2 8 2 9 System Components Board Arrangement System Front Panel System Rear Panel Front Control Panel Buttons and LEDs Drive Tray LEDs PSU LED Fan Failed LED Middle System Fan Backplane LEDs Chapter 3 Hardware Installation and Maintenance 3 1 3 2 3 3 3 4 3 5 3 6 3 7 Server Top Cover Hard Drive Installing a Hard Disk Drive into 2 5 Hard Drive Tray Installing a 3 5 or 2 5 Hard Disk Drive into the Hard Drive Carrier Power Supply Add on Card System Fan Motherboard Daughter Board 20 24 26 28 30 32 Appendix A Installing the CPU Socket LGA2011 Installing the CPU Fan and Heatsink Installation of Memory Modules DIMM Appendix B Installing the Server in a Rack 35 35 38 39 40 40 4U60L Series Chapter 1 Introduction Thank you for purchasing ASRock Rack 4U60L Series
16. nsive press the system reset button to reboot the server without shutting it off and initialize the system Status LED Definitions Power LED Status Description Green Power on Off Power off ID LED Status Description Blue System identification is active Off System identification is disabled LAN1 LAN2 LAN3 LAN4 LEDs Status Description Green Link between system and network or no access Blinking Green Network access HDD Activity LED Status Description Blinking Green HDD access Off HDD idle System Event LED Status Description Off Running or normal operation Red At least one sensor has critical alert System Event LED is not supported for E3C224D4HM 8R motherboard 11 12 2 6 Drive Tray LEDs No Description 1 HDD Power LED 2 HDD Activity LED Status LED Definitions HDD Power LED Status Description Blue HDD powered on Off No power to HDD HDD Activity LED Status Description Solid Green HDD active Blinking Green HDD accessing or reading Red HDD failed Off HDD powered off 4U60L Series 2 7 PSU LED PSU Status LED Status Description Green blinking at 1Hz Standby Cold redundant state or PDB fault protection Green Normal work Amber continuously Module fault protection in operating mode Amber blinking at 1Hz Warning Green blinking at 0 5Hz Power cord unplugged AC loss 2 8 Fan Failed LED Mi
17. or detailed information about motherboard components and features Chapter 2 Server System Overview This chapter provides diagrams showing the location of important components of the server system 4U60L Series 2 1 System Components Front System Fan Fan5 a 5 Front System Fan Fan4 3 Front System Fan Fan3 4 Front System Fan Fan2 5 Front System Fan Fanl 6 60 x 3 5 or 2 5 HDD Bays HDD0 HDD59 7 Middle System Fan Fan9 8 Middle System Fan Pang 9 Middle System Fan Fan7 10 Middle System Fan Fan6 11 Node2 12 Nodel 13 2 x 2 5 Hot Swap HDD Trays for Node 2 14 2 x 2 5 Hot Swap HDD Trays for Node 1 4U60L Series 2 2 Board Arrangement 3 5 2 5 HDD Backplane Board 5 BPB5 3 5 2 5 HDD Backplane Board 4 BPB4 3 5 2 5 HDD Backplane Board 3 BPB3 3 5 2 5 HDD Backplane Board 2 BPB2 3 5 2 5 HDD Backplane Board 1 BPB1 Daughter Board DB Middle Plane Board MPB Expander Board 2 EXPB2 8 Not required for the Single Node Mode Use the EXPBZ Expander Board instead for the Zoning Mode 9 Expander Board 1 EXPB1 sp Dn Oo F amp F W DN 10 Left Power Distribution Board LPDB ll Right Power Distribution Board RPDB Motherboard 2 MB2 Not required for Single Node Mode 13 Motherboard 1 MB1 14 2 5 HDD Backplane Board for Node 2 BPB7 15 2 5 HDD Backplane Board for Node 1 BPB6 You
18. ppliance for High Availability HA mode the 2 5 HDD trays are dedicated for OS installa tion per node 2 5 Front Control Panel Buttons and LEDs Front Control Panel Boards PWR BIN L1 O OL2 30014 4 5 O o 6 OO _ NMI RST 1 MBI Power Button and LED MBI ID Button and LED MBI LANI LAN2 LAN3 LAN4 Activity LEDs MB1 HDD Activity LED RR WwW N MBI System Event LED MBI NMI Nonmaskable Interrupt Button MBI System Reset Button MB2 Power Button and LED MB2 ID Button and LED 10 MB2 LANI LAN2 LAN3 LAN4 Activity LEDs 11 MB2 HDD Activity LED 12 MB2 System Event LED 13 MB2 NMI Nonmaskable Interrupt Button ro Mon SI ME wi 14 MB2 System Reset Button Please be noted that the functions are supported depending on the type of the motherboard Power Button Press the power switch button to toggle the system power on and off To remove all power from the system completely disconnect the power cord from the server 10 4U60L Series ID Button Press the ID button to toggle the front panel ID LED and the baseboard ID LED on and off You are able to locate the server you re working on from behind a rack of servers NMI Nonmaskable Interrupt Button Press the NMI button with a paper clip or pin to generate a nonmaskable interrupt and to put the server in a halt state for examination System Reset Button When the system is completely unrespo
19. ry Box Support CD User Manual Quantity for Different Mode HA oo EN ER Oo FF N N Un 1 1 Zoning Single Node Ka fF Fr O O me I NO W me 1 1 For more details about motherboard configurations please refer to the section entitled 3 6 Motherboard The system supports E3C224D4HM 8R motherboard Please go the official website for the latest supported list and information Only one of the daughter boards is pre installed You can find the other two in the accessory box W If any items are missing or appear damaged contact your authorized dealer 4U60L Series 1 2 Specifications 4U60L Series Form Factor 4U Rackmount Dimension 35 4 x 16 9 x 6 94 900 x 430 x 176 5 mm DxWxH Chassis ears excluded Support MB Size Half Width 13 x 5 96 330 x 151 mm Buttons e 2 x Power On Off buttons 2x ID buttons e 2 x System reset buttons e 2x NMI buttons LEDs 2 x Power LEDs 2x ID LEDs 2 x HDD activity LEDs e 8x LAN activity LEDs 2 x System Event LEDs System Event LED is not supported for E3C224D4HM 8R motherboard I O Ports 4x USB 2 0 ports External e 60 x 3 5 Bay HDD 12Gb s e 4x 2 5 Bay HDD 2 for each motherboard Fan Front 5 x 80 38 mm system fans Fan Middle 4 x 92 38 mm system fans Capacity 4 3 1 Redundant Output Watts 800W Efficiency Platinum Please refer to the user manual of the motherboard you use f
20. server and attach the slide rail assemblies to the rack Slide Rail a gt a Chassis Rail Removing the Chassis Rail from the Slide Rail Assembly Pull out the inner chassis rail from the rail assembly 2 Push the white chassis rail release button toward the front and simultaneously withdraw the chassis rail from the slide rail assembly 3 Repeat for the remaining rail assembly 39 40 To slide a chassis rail back into the slide rail assembly slide the blue release tab toward the ST rear and simultaneously slide the chassis rail into the slide rail assembly until it is locked and cannot be pushed further Attaching the Chassis Rails to the Server 1 Position a chassis rail along one side of the chassis and align the keyhole openings on the chassis rail with the keyhole openings on the side of the chassis Secure the chassis rail to the server chassis with screws Repeat for the remaining chassis rail AU60L Series Attaching the Slide Rail Assemblies to the Rack 1 Determine where to attach the slide rails Make sure you have enough free space above the slide rail bracket for the chassis 4U Server dy Free Space x Joy Su 41 42 2 3 Extend the pre attached front and rear adjustable brackets on the slide Rear Bracket 4 Ds AU60L Series Align the holes on the brackets with
21. table working environment Avoid dust and dirt because contaminants may cause malfunctions 3 Ground yourself properly before touching any system component A discharge of static electricity may damage components Wear a grounded wrist strap if available After all components are well installed then you can connect the power cord to the AC outlet and then press the Power button to power on the server 15 16 3 1 Server Top Cover Removing the Server Top Cover A 1 Before removing the top covers power off the server and unplug the power cord 2 The system must be operated with all the chassis top covers installed to ensure proper cooling 1 Remove the eight screws that secure the top cover to the chassis 2 Push the top cover toward the FRONT of the chassis to remove the cover from the locked position 3 Lift up and remove the top cover AU60L Series Installing the Server Top Cover 1 Lower the top cover on the chassis making sure the side latches align with the cutouts 2 Slide the top front cover toward the REAR of the chassis 3 Secure the top cover with the eight screws 17 18 3 2 Hard Drive 3 2 1 Installing a Hard Disk Drive into 2 5 Hard Drive Tray The 4U60L series chassis supports hot swappable 2 5 hard drives Four 2 5 hard drive trays are located on the rear of the chassis Removing 2 5 Hard Drive Trays from the Chassis 1 Press the locking lever latch on the drive tray to
22. unlock the retention lever 2 Rotate the lever out and away from the module bay and pull the hard drive out of the HDD tray AU60L Series Installing a 2 5 Hard Drive to the Hard Drive Tray 1 Place a 2 5 HDD into the tray with the printed circuit board side facing down Carefully align the mounting holes in the hard drive and the tray 2 Secure the hard drive using the two screws 3 Slide the drive tray into the HDD bay until the drive is fully seated 4 Push in the locking lever to lock the HDD tray into place 19 3 2 2 Installing a 3 5 or 2 5 Hard Disk Drive into the Hard Drive Carrier Removing a Hard Drive Carrier from the Chassis 1 Push back the black release latch 2 While holding the latch back in the unlocked position pull the hard drive carrier up and out towards you Release the latch after the carrier has been removed 20 AU60L Series Installing a 3 5 Hard Drive to the Hard Drive Carrier 1 Remove the screws to disengage the hard drive mounting bracket from the carrier 2 Place the 3 5 HDD into the bracket with the label facing up and the connector end toward the opening of the bracket Carefully align the mounting holes in the hard drive and the carrier 3 Use the four screws to secure the hard drive into the bracket Hard Drive Mounting Bracket 21 22 Installing a 2 5 Hard Drive to the Hard Drive Carrier od
Download Pdf Manuals
Related Search
Related Contents
Hitachi HLC26R1 User's Manual 取扱説明書 Kuppersbusch USA Kitchen Hoods User's Manual Guia do usuário Éléments de langage des données Richard Winter, Jeffrey Installation Manual - Astal Security Technologies 基本仕様 インターフェイス仕様 サーボアンプ仕様 Programmable Solar Charge Controller with Negative Ground 使いかた Copyright © All rights reserved.