Home

USER`S MANUAL Ethernet 10/100 Transceiver Series DL221/DL221A

image

Contents

1. SI S2 53 54 55 S 7 S8 S1 2 S3 S4 S5 S6 S7 S8 FIBER OPTIC PORT CONFIGURATION NOTE Once the DIP switches have been set to the desired settings the configuration must be locked into the unit This is accomplished using DIP switch 6 After each configuration change move S6 to the down position leave it there for at least one second and then move S6 to the up position This locks the configuration into the Series DL221 DL221A transceiver When the reset DIP switch 6 is down the system will not operate Be sure to return S6 to the up position
2. INSTALLATION O Connect the Cat5 cable to between the ethernet port and the Series DL221 DL221A transceiver s 10 100BaseT port O Connect the fiber optic cable s to the Series DL221 DL221A transceiver s fiber optic port s The optical patch cord s sent with the unit may be used if needed O Configure the Series DL221 DL221A transceiver using the configuration chart on page 7 Attach the power cord provided with the unit to the power inlet on the back of the transceiver Connect the other end of the power cord to the AC line voltage source Verify that the power LED is lit green Verify the configuration status using the front panel LEDs Copper link not working Both Link LED at 100M when the and 100 BaseTX DL221 is connected to LED not lit 100 Mbps or 10 100 Mbps device Copper link not working Link LED not lit at 10M when the DL221 is connected to 10M device copper side The DL221 is not recognizing full duplex when DL221 connected to NWAY full duplex copper side FDX LED not lit Problem Indication Corrective Action On the setup mode switches check that S1 is DOWN or S1 is UP and S2 is DOWN On the setup mode switches move S6 to the DOWN position and move it back to the UP position after one second Check if the connected device is working properly at 100 Mbps Check the interconnection between the DL221 and the device On the setup mo
3. USER S MANUAL Ethernet 10 100 Transceiver Series DL221 DL221A June 1999 ETHERNET 10 100 TRANSCEIVER INSTRUCTION MANUAL SERIES DL221 DL221A INTRODUCTION Thank you for purchasing the Radiant Communications Series DL221 DL221A fiber optic transceiver We hope that this manual will help you quickly and easily install your transceiver If you still need help installing or troubleshooting your transceiver after reading this guide please call our tech support department at 1 800 969 3427 This manual details the installation procedures specifications and trouble shooting guidelines for the Radiant Communications Series DL221 DL221A family of fiber optic transceivers CONTENTS OF SHIPPING CONTAINER The shipping container should contain the following items O One 1 Series DL221 DL221A transceiver O One 1 Power Cord O One 1 CAT5 straight cable O This manual WARRANTY Radiant Communications Corporation warrants that at the time of shipment the products manufactured by Radiant Communications will be free from defects in material and workmanship and will conform to the specifications furnished and approved by Radiant Communications Corporation Should any defects appear within one year from date of shipment Radiant Communications Corporation shall at its sole discretion repair or replace the defective unit Defected units shall not be accepted for return or repair without prior authorization from
4. The electrical section is capable of interfacing with any 10BaseT or 100BaseT RJ 45 twisted pair port If the ethernet port supports auto negotiation the DL221 A can be set to auto negotiate for optimum performance If the ethernet port does not support auto negotiation or if a fixed data rate and or fixed half or full duplex configuration is desired the Series DL221 DL221A transceivers can be forced into 10BaseT or 100BaseT mode and forced into half or full duplex mode In addition a crossover switch is pro vided which allows the Series DL221 DL221A transceivers to directly connect to either a standard or a crossover ethernet port The optical section is a 100BaseFX connection at all times The DL221 family of transceivers supports bi directional transmission over two single mode fibers The DL221A family of transceivers supports bi directional transmission over a single mode fiber In both cases Radiant s technology allows for extended transmission distances beyond the ethernet standard Problem Indication _ Corrective Action Improper network traffic Runt and late On the setup mode switches collision move S6 to the DOWN position and move it back to the UP position after one second Check the channel configuration Check that both ends of the fiber optic link are set to the same mode Half Duplex or Full Duplex Check that both sides of the UTP connection are in the same mode 10 Mbps Half d
5. Radiant Communications Return shipments to Radiant Communications Corporation shall be at the buyer s expense Radiant Communications will return repaired or replacement equipment prepaid via best way This warranty excludes all other expressed or implied warranties of merchantability fitness or otherwise Items manufactured by suppliers other than Radiant Communications Corporation used with the equipment covered by this document are not eligible under the terms of this warranty Radiant Communications assumes no responsibility for the performance or reliability of third party products Radiant Communications Corporation will not be liable for any special or consequential damages nor for loss damages or expenses directly or indirectly arising from the improper use of the products either as standalone devices or used in conjunction with other equipment and material This warranty does not extend to any products manufactured by Radiant Communications which have been subjected to misuse neglect accident improper installation an act of God or in viola tion of the instructions furnished by Radiant Communications SPECIFICATIONS Standard Compliance IEEE802 3u 100BaseTx 100BaseFx 10BaseT 100BaseTx Port e RJ 45 connector e Half full duplex support via auto negotiation or manual 100m over UTP STP 100 ohm cat 5 cable e Auto polarity correction e MDI II MDI X selection e 10BaseT switch selected 100BaseFx Port
6. e 1300nm SC connectors Optional Single Fiber DL221A e Distance gt 100 km DL221 SMSP e Full nalf duplex switch selected Diagnostics Per Channel e Full duplex Link Activity 100BaseFx side Per System e Power dual if redundant PS present Controls Fiber side FDX HDX Copper side 10 100 Mbps FDX HDX Autosensing disable enable Environmental Physical Power supply 100 240 VAC 50 60 Hz Power consumption 5 W max Operating temperature 0 45 C 32 113 F Storage temperature 300 65 C 220 1490F Humidity 10 90 non condensing NOTE Specifications subject to change without prior notice GENERAL DESCRIPTION The Radiant Communications Series DL221 DL221A transceivers are used to connect two active ethernet network components together over a fiber optic cable Radiant s unique technology allows the same transceiver to be used for connecting 10BaseT or 100BaseT components together The Radiant Communications Series DL221 DL221A transceivers allow for extended fiber trans mission distances in many cases greater than 100 KM In addi tion the Series DL221A transceivers allow for bi directional full duplex transmission between ethernet components over a single optical fiber It is convenient to think of the Series DL221 DL221A transceivers as having two sections an electrical section which interfaces to the ethernet component and an optical section which interfaces to the fiber optic cable
7. FIGURATION OF THE DL221 DL221A The DIP switches on the front panel are used to configure the DL221 DL221A Use a flat head miniature screwdriver or equiva lent to set the DIP switches to the desired setting Use the follow ing tables to determine the proper switch settings for the desired configuration S1 S2 S3 S4 S5 S6 S7 S8 Up Auto sensing Disable Up Normal Down Auto sensing Enable T PAN ae When Auto sensing Down DON T CARE is Enabled Down 100BaseTx is Disabled Up DON T CARE Down DON T CARE Down Reset When Auto sensing is Enabled Up 10 100BaseTx HDX Down 10 100BaseTx FDX When Auto sensing is Disabled Up 10 100BaseFx HDX Down 10 100BaseFx FDX Note After each configuration change move S6 to down position and move up backatter one second TYPICAL SETTINGS FOR ETHERNET SERVICE TYPES m L Set NWAY Auto Negotiation FACTORY DEFAULT 10 Mbps Half Duplex 10 Mbps Full Duplex 100 Mbps Half Duplex 100 Mbps Full Duplex Don t Care Sl S2 S3 S4 S5 S6 S7 S8 S1 S2 S3 S4 S5 S6 S7 S8 S1 S2 S3 S4 S5 S6 7 8
8. de switches check that the S1 is DOWN OR S1 is UP and S2 is UP On the mode setup switches move S6 to the DOWN position and move it back to the UP position after one second Check that the connected device is working properly 10 Mbps Check the interconnection between the DL221 and the device On setup mode switches check that S1 is DOWN On the mode setup switches move S6 to the DOWN position and move it back to the UP position after one second Check that the connected device is NWAY and full duplex cable Check the interconnection between the DL221 and the device TROUBLESHOOTING Problem Indication Corrective Action __ No power Main power LED Check that the power supply not lit cable is firmly connected to the main power supply and rackmount power source Check that the AC input power source is between 100 and 240 VAC Network problems No communica On the mode setup switches tion on network move S6 to the Down position and move it back to the UP position after one second Copper link not working Link LED not lit Check that straight cross is OUT Check that straight cross in IN for On the mode setup switch move S6 to the DOWN position and move it back to the UP position after one second Check that the connected device is working properly at 100 Mbps or 10 Mbps Check that the connection cable is well connected at both ends 10 CON
9. ot lit position after one second On the setup mode switches check that the S1 is DOWN OR S1 is UP and S3 is UP On the mode setup switches move S6 to the DOWN position and move it back to the UP position after one second Check that the connected device is half duplex only Check the interconnection between the DL221 and the device Check that the receive fiber is properly connected to the transmit port of the remote fiber device and the transmit port to the receive port of the remote device Check that the fiber optic power is higher than 30 dbm on the receive fiber connector at the DL221 end 26dBm for DL221A Check the remote device s receive port is properly con nected to the transmit fiber optic port of the DL221 Front Panel View Straight Crossover selector MDI II MDI X 10 100BaseTX Connector Twisted Pair Status LEDs LINK twisted pair link present RCV receive data on twisted pair port 100TX Twisted pair is working at 100Mps off 10Mps FDX Full duplex operation off half duplex Mode Select Switches 100BaseFX fiber optic Status LEDs LINK fiber optic link present RCV receive data on fiber optic port FDX Full duplex operation off half duplex Optical Connectors Typically SC connectors other options are available DL221 TX on left RX on right DL221A TX and RX combined onto one fiber Power LED
10. uplex or 10 Mbps full duplex or 100 Mbps Half Duplex or 100 Mbps full duplex If the problem persists after carrying out the procedure do the following exchange two different channels with one another both copper and fiber connections and re perform the requested setup If the problem still persists there is probably some sort of general network failure Contact the Radiant Communications technical support department for assistance Tel 908 757 7444 or 800 969 3427 Fax 908 757 8666 E mail radiant3 ix netcom com 13 FRONT PANEL CONNECTIONS amp INDICATORS All connections except power to the DL221 DL221A are made at the front panel Below is a picture of a DL221 Front Panel The DL221A is identical except that the duplex fiber connector is replaced with a single fiber connector Please familiarize yourself with the front panel before attempting to configure the transceiver Problem Indication _ Corrective Action The DL221 full duplex FDX LED not lit On the setup mode switches is not working when the check that S1 is UP and S3 is DL221 is connected to DOWN the full duplex without NWAY capability copper side On the setup mode switches move S6 to the DOWN position and move it back to the UP The DL221 half duplex is not working when the DL221 is connected to the NWAY capability copper side Fiber link not working FDX LED lit Link LED 100BaseFx n

Download Pdf Manuals

image

Related Search

Related Contents

Eglo 81751  LRP 81801  Manual de Instrucciones L:7 :9>I>DC  L`univers bariolé de la « pasta » et des sauces  integrale mode d`emploi  Aide pour les institutions  MGC900(PDF/2.4MB)  How To Configure Modbus TCP Slave with Unity Pro L    Scheda tecnica - Chiudi e vai sul sito ien  

Copyright © All rights reserved.
Failed to retrieve file