1. Do not use the instrument in areas subject to rapid temperature fluctuations e The clamping JAWS is precision assembled to ensure high performance When using the clamp do not apply any intense mechanical shock vibration or force to the clamping JAWS If dust or any other foreign matter gets in the clamping JAWS do not close the clamping cores tight First remove the dust and then make sure the clamping cores on both sides close smoothly Measuring Method O O OOOO N CAUTION m To avoid damage to instrument Do not apply a current exceeding the maximum allowable current as this may cause damage to the instrument 1 Turn the digital multimeter s power on and then set the function switch to AC V 2 Connect the lead plugs from the clamp probe to the digital multimeter input terminals In this case connect the red plug to terminal V the black plug to terminal com 3 Squeeze on the Open Close lever to open the clamping JAWS and clamp one of the wires to be measured Make sure that the end of the clamp is closed securely 4 Read the indication value of the digital multimeter lt The current value calculation gt Example When the output voltage is 150 0 mV Current 1 e 15 00A For Precise Measurements e Clamp only one wire Clamping a tough rubber sheathed cable and a parallel PVC cable together disables measurement e When performing a measurement hold the probe so that the measured conductor
2. Phone 61 2 8870 1100 Facsimile 61 2 8870 1111 YOKOGAWA INDIA LTD INDIA Phone 91 80 4158 6000 Facsimile 91 80 2852 1441 YOKOGAWA SHANGHAI TRADING CO LTD CHINA Phone 86 21 6239 6363 Facsimile 86 21 6880 4987 YOKOGAWA MIDDLE EAST B S C C BAHRAIN Phone 973 17 358100 Facsimile 973 17 336100 YOKOGAWA ELECTRIC CIS LTD RUSSIAN FEDERATION Phone 7 495 737 7868 Facsimile 7 495 737 7869 IM3E 2011 7 Printed in Japan Regarding Safe Use of This Product When operating the instrument be sure to observe the cautionary nots given below to ensure correct and safe use of the instrument If you use the instrument in any way other than as instructed in this manual the instrument s protective measures may be impaired Yokogawa is by no means liable for any damage resulting from use of the instrument in contradiction to these cautionary notes The following safety symbols are used on the instrument and in this manual Z N WARNING Indicates a hazard that may result in the loss of life or serious injury of the user unless the described instruction is abided by CAUTION Indicates a hazard that may result in an injury to the user and or physical damage to the product or other equipment unless the described instruction is abided by A Danger Handle with Care This mark indicates that operator must refer to an explanation in the instruction manual in order to avoid risk of injury or death of person nel o
3. cable runs at the center of the clamp e Ensure that the orientation of the clamp to the direction of the conductor cable power source load is correct as shown below when voltage and current phase related measurement The output waveform will thus be positive and the current phase can be correctly measured Do not connect to the output terminals a resistive load less than 100 KQ or a capacitive load over 100 pF Otherwise an error may result e Ensure that the clamping JAWS is propely closed SOURCE Conductor cable JAWS Open Close gt Lever Barrier LOAD K External Dimensions Clamp on Probe Unit mm inch 130 5 12 86 3 39 Measurement Categories A Internal Wiring Jeon om Board Entrance NEET DA i Cable fa H mai CAT M oati ig Fixed Equipment 1 1 2 Outlet etc Equipment Specifications Measurement range 0 to 400 Arms AC 600 Apk Output voltage 0 to 4 Vrms AC 10 mV A Accuracy Amplitude 1 5 rdg 0 4 mV 20 Hz lt f lt 40 Hz 1 0 rdg 0 2 mV 40 Hz lt f lt 1 kHz 0 8 0 2xf kHz rdg 0 2 0 04xf kHz mV 1 kHz lt f lt 20 kHz Phase 3 45 Hz to 1kHz for temperature of 23 C 5 C relative humidity of 35 to 75 and sinewave input Temperature coefficient 0 05 f s C in ranges of 0 to18 C and 2
4. 8 to 50 C Maximum allowed current See the figure below Output impedance Approximately 30 Q Load impedance 100 KQ minimum 100 pF maximum Effect of magnetic fields 0 2 A equivalent or less at 400 A m 50 60 Hz Effect of conductor position Included in accuracy The RATED circuit to earth voltage 600 Vrms AC maximum Withstand voltage 3 7 kVrms AC for one minute across core and casing and across core and output Measurable connector diameter 33 mm maximum Operating temperature and humidity ranges 0 to 50 C 80 RH or less no condensation Storage temperature and humidity ranges 20 to 60 C 90 RH or less no condensation Environmental conditions Operating altitude 2000 m max above sea level indoor use External dimensions Approx 73 W x130 H x 30 D mm Weight Approx 220g Output cable length Approx 2 5 m Accessory User s manual 1 Portable case 1 Safety standards EN 61010 1 EN 61010 2 032 EMC standards e Measurement category II The RATED circuit to earth voltage 00Vrms Measurement category III The RATED circuit to earth voltage 300Vrms Pollution degree 2 Insulation class II Double insulation EN 55011 Class B Group 1 EN 61326 1 Class B EN 61326 2 1 Immunity Effectiveness of radiation immunity Rated accuracy 1 of Maximum output voltage 4 V for th
5. e strength of a radio frequency electromagnetic field of 3 V m Maximum allowable current 400 AJ Maximum allowable current rms 1 kHz 2kHz 5 kHz 10 kHz 20 kHz low voltage installation 20 Hz40 Hz Frequency Measurement ma Description Remarks category CATI For measurements performed on circuits not Circuits not connected to directly connected to MAINS amains power source CAT For measurements performed on circuits directly Appliances portable g connected to the low voltage installation equipment etc CAT III For measurements performed in the building Distribution board installation circuit breaker etc For measurements performed at the source of the Overhead wire cable IV CAT IV systems etc
6. eee User s Model 96001 Manual Clamp on Probe Thank you for purchasing our Clamp on Probe This manual describes the specifications and handling precautions for a Clamp on Probe Before using this product thoroughly read this manual to get a clear understanding on proper use Store this manual in a safe place for future reference RG 108 E 7th Edition Mar 2012 YMI YOKOGAWA Yokogawa Meters amp Instruments Corporation m Cleaning To remove dirt disconnect the lead plugs and gently wipe the outer surface with a clean and soft cloth Do not use a chemical agent such as benzine or paint thinner YOKOGAWA Yokogawa Meters amp Instruments Corporation Yokogawa Meters amp Instruments Corporation International Sales Dept Tachihi Bld No 2 6 1 3 Sakaecho Tachikawa shi Tokyo 190 8586 Japan Phone 81 42 534 1413 Facsimile 81 42 534 1438 YOKOGAWA CORPORATION OF AMERICA U S A Phone 1 800 888 6400 Facsimile 1 770 254 0928 YOKOGAWA EUROPE B V THE NETHERLANDS Euroweg 2 3825 HD Amersfoort THE NETHERLANDS Phone 31 88 4641000 Facsimile 31 88 4641111 YOKOGAWA AMERICA DO SUL LTDA BRAZIL Phone 55 11 5681 2400 Facsimile 55 11 5681 4434 YOKOGAWA ENGINEERING ASIA PTE LTD SINGAPORE Phone 65 6241 9933 Facsimile 65 624 1 2606 YOKOGAWA MEASURING INSTRUMENTS KOREA CORPORATION KOREA Phone 82 2 551 0660 to 0664 Facsimile 82 2 551 0665 YOKOGAWA AUSTRALIA PTY LTD AUSTRALIA
7. r damage to the instrument This symbol indicates that this instrument designed to be applied around or removed from HAZARDOUS LIVE conductors provided if the RATED circuit to earth voltage dose not exceed the value indicated in the measurement category _ This symbol indicates AC voltage current o This symbol indicates double insulation Z WARNING m Strictly observe the following cautionary notes in order to avoid the risk of injury or death of personnel or damage to the instrument due to hazards such as electrical shock e Do not use this product in a place where an explosive gas or vapor is present To avoid a short circuit or an accident to personnel use this product within the RATED circuit to earth voltage of measurement category Do not use the product when there are raindrops or droplets of condensed water on its surface or if your hands are wet e Barrier is for to avoid touching the HAZARDOUS LIVE conductor Be careful not to across the Barrier when using the instrument e Safety protectors such as rubber insulated gloves should be worn to prevent electrical shock when using the instrument Do not use the instrument if there is any damage to the casing or when the casing is removed Do not attempt to repair modify the product yourself as doing so is extremely dangerous Should an abnormality or failure in the product be found contact the vendor from which you purchased the product CAUTION