1. button 1 Unlock and remove the cover Press and E button at the same time for 2 seconds a The set up program display will appear ee ae Pro 9 2 Press the button four times to position the A under FRI 11 Press E button and you will see P1 Print yEAr display where you can set the year digit Press E again to change the year digit PIS Print y EA r You can select either 2 digit or 4 digit by pressing or button Press E button to confirm your setting You will go to P2 Print HYPhEN display where you can set the hyphen between month and date Press E again to set the hyphen You can select either oFF or on by pressing or button Press E button to confirm your setting You will go to the P3 Print Hour display where you can set the printing type of Hour Press E again to change the printing type of Hour You can select either 12H or 24H by pressing P38Print or button Press E button to confirm your setting Hour You will go to the P4 Print minut display where you can set the printing type of Minutes Press E again to change the printing type of Minutes You can select either 60 100A 100b 5 100 or 10 by pressing or button Press E button to confirm your setting You will go to the P5 Print LAngu display where you can set the kind of Language Press E a
2. hange the print length by adjusting Year Error Printing Length Setting Error Digit Type of Hour kind of Languages and 05 Number Digit If the error does not dissapear please contact your local dealer 22 Cleaning For cleaning unplug the power plug and wipe the case with a dry cloth Do not use any chemical solvents or oils to clean or lubricate your PIX 200 This will damage your time recorder stamp To clean inside of your unit blow the dust and dirt out with air 23 APPENDIX enak aaa Diagram of Preprogrammed Comments amp Languages eo ti nt trenen nn on oct mn tr onder A tuesday ke ednesday k US a Thursday a O O O E December ee a toe Tata is a ae ae AAA approved APR D A i oon m EN cor oma a w f oon September oa a gt eee pos a a eee E os E lt a SALID SORTI GEHT USCIT SALID sour our USED UTIL UTIL GEBRA UTIL UTIL USED USED Diagram of Character Code The alphanumeric characters on the upper row are for the second digit of the code and the ones on the far left column are for the first digit of the code i e If you want to program Year Month Date SP Hour Minute AM PM SP A M A N O the code will be 10 11 12 20 13 3A 14 1C 20 41 4D 41 4E 4F IMPRINT IMAGE O5DEC15 8 23AM AMANO __ Space Character ufo 1 2fafejslo rfalola ejoloje F ope oe swfolelr fololep ap ppp BEEBE D a me can jejajef
3. New Jersey 07068 1239 U S A AMANO CINCINNATI CANADA INC 2740 Matheson Blvd East Unit 4 Mississauga Ontario Canada L4W 4X3 AMANO PIONEER ECLIPSE CORPORATION 1 Eclipse Road Sparta North Carolina 28675 0909 U S A AMANO ELECTRONICS EUPORE N V Corporate Office Westerring 2 3600 Genk Belgium AMANO KOREA CORPORATION Woolim E Biz Center2 4F 407 Yangpyeong Dong 3Ga 16 Yeongdeungpo Gu Seoul Korea 150 103 AMANO INTERNATIONAL TRADING SHANGHAI CO LTD Room No 901 Zhongdian Mansion 1029 Laoshan Road W Pudong Shanghai China 200122 AMANO TIME amp AIR SINGAPORE PTE LTD Head Office No 1 Jalan Kilang Timor 02 01 Pacific Tech Centre Singapore 159303 PT AMANO INDONESIA Gedung Pusat Perfilman H Usmar Ismail Lantai 3 JL H R Rasuna Said Kav C 22 Jakarta 12940 Indonesia AMANO CLEANTECH MALAYSIA SDN BHD Head Office Suite A905 7 9th floor West Wing Wisma Consplant 2 No 7 Jalan SS16 1 47500 Subang Jaya Selangor Darul Ehsan Malaysia AMANO MALAYSIA SDN BHD Suite A905 7 9th floor West Wing Wisma Consplant 2 No 7 Jalan SS16 1 47500 Subang Jaya Selangor Darul Ehsan Malaysia Printed in China on recycled paper
4. button In case of other countries you can select either on or off by pressing or button CLOS Sync 5 Press E button to confirm your setting and you will return to set up 9GErANy 4 program display Setting the Time Zone US only This setup is for US only In this setup you can set the time zone or select to disable the Atomic Clock function 1 Unlock and remove the cover Press and E button at the same SEt SUP time for 2 seconds The set up program display will appear PERTE 2 Press the button eleven times to position the A at the fifth from the upper right corner 3 Press E button and you will see P1 LCd diSPly display Press Pd LCd button 3 times to skip to P4 CloC Sync display di 5P Ly 4 Press E button to set the time zone When you set the time zone you need to input the time difference from UTC Universal Time Coordinated Please refer to the following chart PA SINS Time Difference from UTC Major Cities D yn C8 g New York Boston O 6 Chicago Houston Que PST Los Angeles San Francisco 5 When you see the t ZonE display where the hour is blinking select the time difference by pressing button 6 When you need to disable the Atomic Clock function because of failure of radio signal receiving interference an inappropriate location or bad radio wave receiving conditions please press or button until you see CLC
5. code to correct the customized Use below code to change the font of comments the customized comments Sample of changing the font of D E F from One Byte to Two Byte ABCDEFGHI 41 42 43 44 45 46 47 48 49 ABCDEFGHI 41 42 43 in J 44 45 46 in Jn 47 48 49 How to delete the customized comment When the print line number is blinking i e Prn LinE 1 press 1 HOUR button for 3 seconds The blinking will stop and the line number will solidly light up Once the printing length returns to 0 and the line number starts blinking again the line you have selected and the lines afterwards will be deleted Setting the Layout of Customized Comments You can set the layout of Customized Comments to Right Aligned Centered or Left Aligned pee Ngee ae 1 Follow step 1 and 2 on page 9 or continue the steps after 8 of CodeE Setting the customized comments p 9 2 Atthe P1 inPut CodE display press the button and the display will change to P2 Print Layout display Press E to select the layout 3 Press or button to select the layout You can select from Right Center or Left Press E to confirm your setting LAyout 4 You will go to the P3 tEst Print display which is explained below 1 Tee US Test Printing of Customized Comments 1 After confirming the layout press E to test print the customized comments 10 2 When the PA
6. mandatory actions The specific action required is illustrated within the symbol UNPLUG THE PLUG INTRODUCTION Thank you for purchasing the Electronic Time Recorder Stamp PIX 200 from Amano To ensure safe use of this time recorder stamp be sure to thoroughly read this manual before use After you finish reading this manual be sure to store this in a safe place for future reference SPECIFICATIONS This product is supplied with an Approved AC Adapter marked LPS and rated 15 Vdc 1 64 Reference Power Supply AC DC Adapter 100 240VAC 50 60Hz e Power Supply PIX 200 DC15V Power Consumption 1 2A Ambient Temperature 10 C to 45 C 14 deg F to 113 deg F Note In case you are using NiMH battery Optional Full Power Reserve the ambient temperature is O Cto 40 C eo Ambient Humidity 10 to 90 RH non condensing e Dimensions 159 W X163 H X171 D mm o Weight 2 2kg approximately 4 85 Ibs e Environment Indoor use only dust free environment Keep out of direct sunlight ACCESSORIES The following accessories are provided for PIX 200 as standard After unpacking please make sure that all of the accessories are provided Operation Manual This operation manual Keys one pair 2 keys PIX 200 1 unit 1 copy Please note that specifications appearance and description are subject to change without notice due to product enhancements e This manual has been prepared carefully in every detail howe
7. note that the clock may be unable to receive radio wave signals properly under the following conditions Inside a large building between tall buildings underground building without windows Close to overhead power lines TV stations and train cables Close to home electrical appliances or OA devices such as TV s PC s refrigerators or fax machines Close to furniture made of steel such as steel desk In places generating radio interference such as near construction sites airports or in heavy traffic Inside a vehicle train or airplanes setting the Atomic Clock Germany UK and others In this setup you can select DCF in Germany MSF in UK or disable the Atomic Clock function The factory default is set to DCF in Germany 1 2 3 The set up program display will appear SEt SUP P ro 98 8 Unlock and remove the cover Press and E button at the same time for 2 seconds P1 LCd Press the button eleven times to position the A at the fifth d10PLyE from the upper right corner Press E button and you will see P1 LCd diSPly display Press 1 O button 3 times to skip to P4 CloC Sync display 4 Press E button to select official standard frequency or disable the PA CEC Atomic Clock If you are in Europe you can select from GErAny DCF in Germany britAN MSF in UK or oFF Disable the atomic 5 yn Cet clock by pressing or
8. of parts LCD display print position adjuster function of 5 control buttons and how to remove the cover and packing material Names and Functions of Parts The following describes the names and functions of parts on this unit External View Internal View AC Power Adapter Print Button Key Plate O E Button Button Button LCD Display 550 Hour 1 Min Button Ribbon Cartridge Paper Detecting Sensor LCD Display Print Window Component Name Major Function Key Use the keys that came with the unit to open the cover Back Plate Mount the back plate to the wall when wall mounting the unit LCD Display Refer to page 4 LCD Display You can press this button to imprint when you choose manual or Print Button either when setting the printing activation refer to page 13 Print Window Large window for accurate printing position Refer to page 5 Functions of 5 control buttons Ribbon Ribbon Cartridge ay o replace lela cartridge refer ES page 22 e menanamkan Clear LED visibility There are two sensors which detects the paper to Sensor automatically print refer to page 13 LCD Display Ribbon Cartridge Day of the week Program Indicator Ink Capacity A de xX A Program Indicator INK E m a an an F CD q No RPT ee p Atomic Time Synchronization Indicator Bodaoooa a bas eN KH III gt Se Ma MA o Repeat Times pro TIT gt AM PM Indicator OO na Ba IN Time Hour
9. use button when you input the password 1 N ATOMIC CLOCK FEATURE ss PIX 200 has the atomic clock radio controlled clock feature which displays the current time precisely by automatically receiving time code signals on long wave radio from the transmitting station The unit receives the time code signal via its built in antenna system PIX 200 can receive standard frequencies from countries listed in the table below Transmitting Station The United States WWVB 60kHz Fort Collins Colorado DCF 77 5kHz Mainfligen Frankfurt The United Kingdom MSF 60kHz Rugby Japan JJY 40kHz Fukushima East Japan JJY 60kHz Saga West Japan Note The atomic clock function is only available at the country you have purchased PIX 200 The Atomic Time Synchronization Indicator in the LCD display indicates the status of the signal Searching for Signal Blinking Found Signal Completed Time Time Synchronization Automatic Reception Synchronization Failure e The atomic clock feature will automatically start searching for time code signals under the following condition when the time displayed on the unit is within 15 minutes from the official standard time of the location Refer to the Annex at the end of the manual for details about reception duration 1 Every time you plug in the unit It will search signals for 15 minutes 2 Every night starting at 1 15am until 4 00am For 2 hours 46 minutes when the unit is plugged e
10. will see End 10 29 2006 display and you can set the end date of Daylight E n d 3 2006 1029 E Saving Time Set the Month Date and Year 5 Press E to confirm the end date and you will go to the Hour dSt display where you can set the D S T execution time on the beginning Hour dst day Press or button to select the desired hour 02 00 Press E to confirm your setting Note If you are in UK please set the DST execution time at 1 00am Note Once the DST is set the unit automatically updates the settings every year thereafter Note To delete and cancel the daylight saving time setting put the same date into the beginning date and end date Beginning date End date 16 Setting the Display and Password In this setup you can select the display 1 Unlock and remove the cover Press and E button at the same A time for 2 seconds The set up program display will appear EA O ee 2 Press the button eleven times to position the A at the fifth from the upper right corner 3 Press E button and you will see P1 LCd diSPly display where pee SOG di SP Ey you can set the display Press E button and you can select either 12 31 06 which displays the Month Date Year or No 12345678 which displays the number or No 123456 RPT 9 which displays the number and repeat times or LinE 3 which displays the line Pa oe di SP number of the customized comm
11. your setting 15 Setting the Daylight Saving Time Daylight Saving Time Function e At2 00am on the beginning day of daylight saving time the clock automatically gains one hour to show 3 00am The clock will change from 1 59am to 3 00am e When 2 00am comes on the end day of the daylight saving time it loses one hour and returns to 1 00am The clock will change from 1 59am to 1 00am eo Inthe case of Germany when 3 00am comes on the end day of the daylight saving time it loses one hour and returns to 2 00am The clock will change from 2 59am to 2 00am The factory default of DST is as follow You can set the DST on by setting the begin time and ending time even though the factory default is DST Off The United States DST On es Germany UK DST On DST On Japan and Others DST Off DST Off 1 Unlock and remove the cover Press and E button at the same time for 2 seconds The set up program display will appear 2 Press the button ten times to position the A at the fourth SEt SUP from the upper right corner 3 Press E button and you will see bEgn04 02 2006 display where P ro 983 you can set the beginning date of Daylight Saving Time When the month is blinking press or button to set the month When the bE9n 2006 month is set press E button and set the date Once you set the date 0 4 O 2 press E button to set the year 4 Once you confirm the beginning date by pressing E you
12. 0 00s 00 00s 700 35s 00 35s 00 36s 01 00s The minute increments by 1 every 36 seconds _ gt Pr A 33 00s 55 00s 33 minutes 33 60 100 55 33 018 55 01s Le salon ol o os os 95 33 35s 55 35s 33 36s 56 00s 59 24s 99 00s 59 57s 99 33s 59 58s 99 34s 59 59s 99 35s Annex PIX 200 ATOMIC CLOCK Time code signal reception duration The target duration of PIX 200 to receive time code signals is as follow e When the radio wave condition is good it will take about 3 minutes until it completes time synchronization eo At the automatic reception every night from 1 15am to 4 00am it may take up to 166 minutes to complete time synchronization depending on the radio wave condition e When the radio wave condition is bad 1 At the automatic reception every night it will discontinue the reception when it passes 166 minutes 4 00am 2 At the automatic reception when you plug in the unit it will discontinue the reception after 15 minutes 3 When you manually start reception it will continue to search for time code signals forever Please refer to page 18 of the operation manual to see how to start reception manually CJR543505 08 T9111CH A AMANO Corporation 275 Mamedo Kohoku Yokohama Japan 222 8558 TEL 81 45 401 1508 FAX 81 45 439 1151 AMANO HomePage _http www amano co jp English AMANO CINCINNATI INC Corporate Headquarters 140 Harrison Avenue Roseland
13. Electronic Time Recorder Stamp PIX 200 Operation Manual IMPORTANT SAFETY INFORMATION The precautions stated on this operation manual are categorized by the level and content of danger as follows Please be sure to read this before using the product WARNING This mark shows that there are possibilities that may cause an accident resulting in human serious injury or death if you handle the product incorrectly A CAUTION This mark shows that there are possibilities that may cause an accident resulting in human injury or property damage if you handle the product incorrectly Serious injury includes loss of eyesight injury burns of varying severity electric shock bone fracture poisoning and other that have serious after effects or any other injury that requires hospitalization and or prolonged medical treatment Human injury includes injuries such as burn injury and electric shock that does not require hospitalization and or prolonged medical care Property damage includes damages to house household goods livestock and pets Safety Icons Used Throughout This Manual AThis symbol stands for Warnings and Cautions The specific warning or Electric Shock Waning Caution is illustrated within the symbol Y This symbol stands for prohibited action The specific action prohibited is DO NOT illustrated within the symbol REMODEL This symbol stands for essential requirements and
14. HER Print the Leading 0 Disable 0 and print the number right aligned Disable 0 and print the number centered Disable 0 and print the number left aligned Note Leading Zero is applied to Number Month Date Julian Date and Hour Setting the Printing Length PIX 200 will automatically change the character font when you set the printing length However if you have selected to use the Customized Comments this function is not available Input the printing length by mm unit If the value is smaller than the minimum length you will see an error message Error 05 when putting the cover on The minimum length depends on the imprint format you have chosen and the maximum length is 35mm 1 Unlock and remove the cover Press and E button at the same time for 2 seconds A The set up program display will appear SEt SUP 2 Press the button five times to position the A under SAT DE Press E button and you will see Pr LEnth display where you can set the printing length You can select the length by A pressing or button Press E button to confirm your setting PrsLEnth 4 When an error message Error 5 appears on the display change 3 5 the length and try again Setting of Printing Activation Detecting Sensor PIX 200 has two paper detecting sensor which enables to automatically print by simply inserting a card or piece of paper In this setup you can select the printing activation as below and d
15. Minute Second Programming The LCD Display contains an Ink Capacity gauge This gauge indicates the amount of ink remaining in the ribbon cartridge using four bar segments from E Empty to F Full The PIX 200 calculates the ink capacity of the ribbon cartridge from the number of imprints made As the ink capacity decreases the bars in the gauge will disappear When the ribbon reaches below 25 capacity the word INK and E will blink until the ribbon is replaced and the ink counter is reset Refer to page 22 for Ribbon Cartridge Replacement and Ink counter reset Print Position Adjuster Slide Lever Print position from the paper edge is adjustable by pressing and sliding the print position adjuster slide lever located at the right outside bottom of the unit The slide lever can be adjusted using the latching function that moves 17 steps by 1 5mm Total 25 5mm This adjuster will move the paper detecting sensor forward or backward and change the margin from the paper edge to the print Bottom View Print Position Adjuster Minimum distance from edge of form to print is approximately 0 5mm 2 0mm When you slide the slide lever to the front of the machine Maximum distance from edge of form to print is approximately 25 5mm from the minimum distance When you slide the slide lever to the back of the machine 12 20 15 40 lt gt 0 5 2 0mm El 12 20 15 40 25 5mm Functions of 5 co
16. PEr button display is blinking insert a paper and A press or button to test print P3 LED Press E button to end Pe id If you would like to return to the set up program display press E button at the P4 End display A PAP B i CAUTION Touching the printing area while test printing may cause an a accident resulting in human injury Changing the Print Position You can set the print position in two directions One is to imprint on the left side of the paper and the other is to imprint on the right side of the paper A Factory default is set to Right SEt SUP 1 Unlock and remove the cover Pro 9 Press and E button at the same time for 2 seconds The set up program display will appear Press the button three times to position the A under THU Press E button and you will see Prn PoSn right blinking Press or button to change to LEFT 4 Press E to confirm the setting and you will go back to the set up A program display Pons Poon LEPR Setting the Print Pattern In this setup the Year digit the print of Hyphen between month and date the printing type of Hour the printing type of Minutes Refer to page 26 Diagram of Printing Type of Minutes kind of Language the preprogrammed comment the type of Zero and the print of Leading Zero can be set At the P1 Print yEAr display you can skip to the desired setting by pressing or
17. SynC oFF Press E button to confirm your setting and you will go to P5 End display 7 Press E again to return to set up program display CLC8 5ynC NOTE If the unit is unable to receive radio signals please move the unit to another place where it can receive radio signals o Fr a 20 INSTALLATION amp MAINTENANCE Wall Mounting The wall mounting is implemented by our authorized dealers IMPORTANT This work should not be performed by the customer If the PIX 200 is insufficiently mounted it may fall resulting in damage to the unit or a personal injury When mounting the PIX 200 on a concrete wall or other special wall material prepare special screws 1 Remove the cover and remove the back plate by pressing the tab 2 Using the back plate as a template mark the lower mounting hole on the wall 3 Mount the plate using a 10 wood screw or equivalent 4 Level the back plate and mark the location of the two upper mounting holes Secure to the wooden wall thicker than 10mm wall using 10 wood screws or equivalent 5 Feed the cable of AC power adapter through one of the holes in the back plate 6 Align the clock with the two upper tabs on the back plate Tilt the back of the clock upwards to fully insert the back plate tabs into the clock Be careful not to pinch the power cord wi
18. When the time displayed on the unit is different more than 15 minutes from the official standard time of the location you can take one of the following actions 1 Remove the cover and press and E button at the same time for two seconds The L 0 USA L 0 Geny Germany or L 0 brtn UK L 6 U5A E 2 3 9 9 59 display will appear Press button and the unit will start searching for time code signals The level of the radio wave strength will be displayed from L 0 to L 6 L 6 means that the radio wave is very strong Press E button to stop searching for time code signals 18 2 Change the time by hand Please refer to page 6 Setting the Time or page 7 Easy Way to Set the Time Note When the Completed Time Synchronization mark is on it means that the unit has received the time code signal within 24 hours e The clock may display the wrong time This may happen if it fails to receive radio wave signals properly because of interference an inappropriate location or bad radio wave receiving conditions Should this happen move the clock to another place such as near a window where it can receive radio wave signals Please face the ribbon carriage side of the unit to the direction of the radio wave signals e Even if the clock is unable to receive radio wave signals its Quartz mechanism will continue to keep the time Inappropriate places to keep the unit Please
19. at While the imprint number is blinking adjust the number a Pr8ordEr using and button Press the E button to confirm the imprint format 2 4 You will return to the set up program display A SEt 8UP IMPRINT FORMAT DIAGRAM Y Year M Month D Date W Day of the week h Hour m Minute Pro 9 s Second C Comment N Number 6 digits except No 21 2 digits and No 22 4 digits Factory Default No 3 6lyYMD Ioi 8 DMhm 1 JUN 3 05PM jm Ni O RCVD 1 JUN 05 Refer to page 11 Setting the Print Pattern and page 14 Setting the number to change the 19iMDYC JUN r 05 rcvo 1 JUN 05 RCVD year digit print of hyphen printing type of hour and minutes language preprogrammed comment type of zero leading zero and digits of number 8 Setting the Customized Comments Maximum 3 lines comment can be set to print A Aa PPA Pr8ordEr The maximum printing length per line is 35mm You can check the length at the end of the setting 32 Refer to page 25 Diagram of Character Code to select the character A P1sinPut C od E d Follow step 1 to 3 on page 8 At step 3 select 32 2 Once you confirm 32 by pressing E button the P1 inPut CodE display appears 3 Press E button to program the 1 line Prn LinE 1 display means that you can program the 1 line The 0 on the left side of the Line number shows the printing length of the comment in mm Press E button
20. ave selected the imprint format which includes number Refer to the Imprint Format Diagram on page 8 or you have included number Code No 19 when you have programmed the customized comment Refer to the Diagram of character code on page 25 1 Unlock and remove the cover E Press and E button at the same time for 2 seconds SEt SUP The set up program display will appear BD see E 2 Press the button seven times to position the A at the upper right corner 3 Press E button and you will see P1 Print nubEr display where you can set the starting number by pressing E button Select the number by pressing or button To move to the next digit press E button Press E button to confirm your setting 4 You will see P2 nubEr digit display where you can set the digit of the number by pressing E button Select the digit of the number by pressing or button The digit is available from 1 to 8 Press E button to confirm your setting Press E button again to return to set up program display 14 Setting the Initial Number and Auto Reset In this setup the number will automatically return to the initial number that SEt 8UP A you have programmed at the desired time Pro 9 1 Unlock and remove the cover Press and E button at the same time for 2 seconds PiSu uber The set up program display will appear Le Ate AE 2 Press the button ei
21. c shock If any object metal piece water or other liquid gets inside the unit immediately disconnect the power plug from the power outlet and contact your local dealer for servicing If you continue to use the unit it may cause fire or electric shock a UNPLUG Before replacing the ribbon cassette disconnect the power plug from the power outlet Replacing the ribbon cassette while the power plug is connected may cause injury or electric shock Do not place any metallic objects or containers filled with liquid on the unit Such objects may fall and or spill into the unit and may cause fire or electric PROHIBITED shock Do not place the unit in the oily smoke moisture and dusty atmosphere such as a side of kitchen counter and or humidifier This may cause fire or electric shock O NO MOISTURE Replacing the lithium battery with the wrong type of battery could result in explosion Contact your local dealer for replacement PROHIBITED When disposing of the used lithium battery be sure to follow the local government regulations or contact your local dealer O D J C a 3 Do not place the unit on unstable surface DA ER It may drop or fall which could cause injury O For the wall mounting use a proper fixture and tools suited for wall material which support the weight of this equipment enough If not the unit may fall off which could cause injury When disconnecting the AC adapte
22. ent or L 6 rAdo which displays the level of radio wave strength for the atomic clock signal by pressing or button The level number will increase when the radio wave P3 PASS signal is stronger Press E button to confirm your setting uu or d8 4 When you see the P2 Hour diSPly press E button to select either AM PM 12 00 which is AM PM display or 23 59 which is 24 hour display by pressing or button Press E to confirm your setting PA5 5 5 When you see the P3 PASS word press E button to set the 90 09 2 password The first digit will blink and you can select the first digit by pressing or button Once you select the first digit press E to confirm and select the remaining three digits following the same steps ne ne NOTE When you would like to cancel the password change the 9 yn Cs C kh first digit to and the password will change to 6 After confirming the password you will see P4 CloC SynC where you can set the time zone US only select the Official Standard Frequency Europe and whether to turn on the Atomic Clock function or not When the unit requires the password When you press and E button at the same time for 2 seconds to enter the set up program display When you press 1 HOUR or 1 MIN to change the time In case you forget the password e You can enter the set up program display by entering 1441 Only
23. etecting sensor method Use the Center or Edge sensor Use both sensor or Use the center sensor Will automatically print by inserting a piece of paper time card Will print by pressing the Print Button Will print by pressing the Print Button or inserting a paper time card 13 1 Unlock and remove the cover A Press and E button at the same time for 2 seconds SEt SUP The set up program display will appear 25 6 Press the button six times to position the A under SUN 3 Press E button and you will see P1 Print triger display where A you can set the printing activation Press E button and you can pp pag a select from Auto button or Au Btn by pressing or tr 19 Er button Press E button to confirm your setting 4 When you see the P2 PAPEr dEtEct display press the E button PN You can select from C or E Use the center or edge sensor P28PAPEr CE Edg Use both sensor or CEntEr Use the center sensor dr ti e4 by pressing or button 5 Press E button to confirm your setting ik Press E again to return to the set up program display EE RIOR Note The factory default is set to Auto Automatic for print activation ls A and C or E Use the center or edge sensor for detecting sensor Setting the Number In this setup you can select the starting number and the digits of printed number Please make sure that you h
24. gain to change the kind of Language e You can select English Spanish French German Italian Portuguese roman 123456 or Japan by pressing or button Press E button to confirm your setting Refer to the Diagram of Preprogrammed Comments amp Languages on page 24 You will go to the P6 Print ConEnt display where you can set the preprogrammed comment Press E again to change the preprogrammed comment You can select from number 0 to 12 by pressing or button Press E button to confirm your setting Please refer to the number and comments below SS Eo eS Option _ Received Sent Faxed Void Paid Confirmed Approved Completed Origin File In Out Used Serpe Erg hic E O fare Oeo CO REN CNN USD 10 12 a will go to the P7 SLASH ZEro display where you can set the type of Zero Press E again to change the type of Zero You can select either OFF or on by pressing or button Press E button to confirm your setting Slash Zero on You will go to the P8 LEAd ZEro display where you can set the print of Leading Zero Press E again to change the setting You can select from r OFF C OFF L OFF or on by pressing or button Please refer to the diagram below to select what you need Press E button to confirm your setting PSs LEAd C
25. ght times to position the A at the second from the upper right corner P2 Auto E 3 Press E button and you will see P1 nubEr initAL display where you can set the initial number Press E button and you can select E the number by pressing or button To move to the next digit press E button Press E button to confirm your setting Awe ES Et 4 4 You will see P2 Auto rESEt display where you can set the auto 00 00 reset Press E button and you can select oFF or on by pressing or button Press E button to confirm your setting 5 When you select on the display will change to the clock display Press or button to set the hour and press E to move to the minute Press E button to confirm your setting Setting the Repeat Times of Number In this setup you can select the repeat times of number This function SEt SUP is useful when you need to imprint the same number on more than p n ro 9 one paper Repeat times can be set from 1 to 9 1 Unlock and remove the cover Press and E button at the same time for 2 seconds Nor EP EAt The set up program display will appear 1 2 Press the button nine times to position the A at the third from the upper right corner 3 Press E button and you will see No rEPEAt display where you can set the repeat times of number by pressing or button Press E button to confirm
26. mprint Format No 3 IMPRINT SAMPLE Q5JUN 1 3 05PM i gt f 4 If the imprint is satisfactory the PIX 200 is ready for use A D Gi Setting the Time If the Time Displayed is Incorrect Blinking The illustration on the right shows a sample of the display The shaded area means that the symbols numbers or characters are blinking 1 Unlock and remove the cover 2 Press and E button at the same time for 2 seconds The set up program display will appear 3 Press the E button to set the Hour While the Hour display is blinking adjust the hour using and button Press E button to confirm 07 54 00 4 While the Minute display is blinking adjust the minute using and button Press the E button to confirm the minute The seconds will start from 00 at the time you press the E button However if you do not change the minute the seconds will not start from 00 5 The display will return to the clock display If you need to return to the set up program display press the E button again NOTE When you are using the unit in the US please check if the time zone setting is correct Refer to page 20 A AM 08 53 00 NOTE When the Atomic Clock is built in and you are using the unit in Europe please check if the Atomic Clock setting is correct Refer to page 19 Easy Way to Set the Time If you do not need to adjust the seco
27. n 22 Error Codes A a LS Mp Je Il MN an OMA JI Di Cm 22 Cleaning AR ML AP Dr ee Pa Am Oe TA mae A NA keer wee a 23 APPENDIX Diagram of Preprogrammed Comments amp Languages ee 24 Diagram of Character Code A A E A a 25 Diagram of Font tsttttt ttre 26 Diagram of Printing Type of Minutes aa 26 GUIDEL INES FOR SAFE OPERATION To ensure safe operation please carefully read the following warnings and cautions prior to using the PIX 200 Electronic time recorder stamp O USE ONLY SPECIFIED VOLTAGE O O Z O Y OVERLOAD THE SOCKET Vil PROHIBITED S DO NOT REMODEL Cc Zz TU r C 0 a Do not use with any power voltage other than the specified voltage This may cause fire or electric shock Do not overload on a single socket This may cause fire or electric shock Do not touch the power plug with wet hands This may cause electric shock Do not harm or damage any cords such as power cord etc Also note that putting a heavy object on them pulling or bending them by force will likely damage the power code which may cause fire or electric shock Do not remodel the unit This may cause fire or electric shock If any unusual status is found with the unit such as smoke strange odor heating or other immediately disconnect the power plug from the outlet and contact your local dealer for servicing If you continue to use the unit it may cause fire or electri
28. nds this will be an easy way to set the time 1 Unlock and remove the cover 2 Press 1 HOUR to change the hour and 1 MIN to change the minute The seconds will not start from 00 It will continue to advance while you are setting the clock Setting the Date If the Date Displayed is Incorrect 1 Unlock and remove the cover Press and E button at the same time for 2 seconds The set up program display will appear Press the button to position the A under TUE Press the E button to set the Month While the Month display is blinking adjust the month using and button Press the E button to confirm the month 4 While the Date display is blinking adjust the date using and button Press the E button to confirm the date 5 While the Year display is blinking adjust the year using and button Press the E button to confirm the year 6 You will return to the set up program display A SEt 8UP P rog 2101015 09 30 2005 1 0 2006 1020 SEt 8UP Pro 9 N Setting the Print Order There are 31 selectable imprint format preprogrammed in the unit A Refer to the diagram below e P ro 1 Unlock and remove the cover Press and E button at the same time for 2 seconds E Pr8ordEr The set up program display will appear Press the button twice to position the A under WED 1 3 Press the E button to select the imprint form
29. ntrol buttons button When you press the button you can decrement the set value or move to the left You can also change the information on the display button When you press the button you can increment the set value or move to the right You can also change the information on the display E button You can set the value selected on the display by pressing the E button Thereafter you press this E button you can return to the setting mode 1 HOUR button This button advances the hour in the display by increments of 1 1MIN button This button advances the minutes in the display by increments of 1 Removing the Cover amp Packing Material 1 Insert the key provided and turn counterclockwise to unlock the cover 2 Lift the cover to remove 3 Remove the spacer between the Ribbon Cartridge and the Printer Carriage USING THE TIME RECORDER STAMP Make sure the AC adapter is plugged in while you make changes on the settings NOTE Once you finish changing the settings put the cover on to exit from the set up program mode and return to normal operation mode NOTE Replacing the cover will also lift up the printer carriage in case it stays down Making a Test Print 1 Make sure the AC adapter is plugged in 2 The LED lights up and illuminates the printing position 3 Insert a piece of paper or time card along the guide The unit will automatically print YEAR MONTH DATE and TIME with AM or PM I
30. r be sure to hold the plug not the cord Do not disconnect the AC adapter from the unit for other usage Pulling the power cord may damage the cord and it could result in fire or aa ns electric shock Using the AC adapter for other usage may cause fire or damage the other devise a USE A FIXTURE Z The socket outlet shall be installed near the equipment and shall be easily accessible If any unusual status is found with the unit immediately unplug the power from the outlet Although this instruction manual contains the maintenance information that should not be performed by the end user you may not attempt to service such work yourself This may cause injury or electric shock 09 PROHIBITED Electromagnetic Compatibility and the Low Voltage Directive This apparatus has been verified for compliance with EU European Union directives 89 336 EEC for electromagnetic compatibility EMC for operation at 220 240VAC 50 60Hz and with the low voltage directive 73 23 ECC It bears the CE mark When an apparatus is used in a system EU directives may require that the system is verified for EMC compliance Relation to the Health and the Environment The plastic currently used for the outer enclosure of this apparatus does not contain the halogen substance 2 BEFORE YOU START rrrs terete Before attempting to use the PIX200 time recorder stamp please carefully review this section which covers names and functions
31. sjejafw A o e IC BBD 1 D Week No Be an Date OL Bee o EZ OOOO Oo PA Jemet timo o Jo z s5 2 A EE Preprogrammed o M WespBpoBDon O ES KIMI ONUNU O oo EN g ooon o Start Double Width Byte Undo Emphatic Double Width Byte Undo Space character Note Space Characters in the bold square shown above will not be recognized as One Byte Font 7 dots in width but recognized as a narrow font 5 dots in width When you put Un before the space character when changing the font size the font will be bigger Please refer to page 26 Diagram of Font 20 Diagram of Font The maximum dots which fits in one line is total 148 dots Character__ Font Dots Character Code Common One Byte Emphatic 8 From 10 to 89 A1 to A4 Common Two Byte 9 Excluding IV V VI Two Byte Special Symbols Two Byte 9 From A6 to B5 IV Space Character Un A SO Characters in the Bold Emphatic 6 8 Sguare Refer to page 25 DoubleWidth_ 9 13 V VI Diagram of Printing Type of Minutes ri il SS DDS et 60 1 60 ool oil 02 osl oal osl osl 07 osl os J wano oo of of of of aalala tal sl al of of ol ol ol 1008 5 100 of of of os osl osf 10 10 10 151 A it it 100A One hour 3 600 seconds is divided by 100 and the minutes are printed in 00 99 range The minute increments by 1 every 36 seconds and seconds are printed in 00 35 range 60th min s 100A min s 0
32. th the bracket 7 Once the tabs are inserted tilt the clock back down and push it against the wall The tabs will snap into place 8 Replace the cover and lock it in place a 21 Ribbon Cartridge Replacement NOTE Before replacing the ribbon cartridge disconnect the power plug from the power outlet 1 Remove the cover Te ae 2 Pull the two ribbon release tabs upward 3 While holding the release tabs in an upward position pull the ribbon cartridge out of the cradle 4 Insert a new ribbon underneath the printer head as shown 5 Turn the knob on the cartridge clockwise one turn to take up any slack in the ribbon Connect the power to the outlet 7 Reset the INK capacity gauge by pressing the and buttons at the same time for more than 2 seconds Replace the cover 9 Check the printing quality to confirm that you have installed the ribbon properly Error Codes In the event of an error an error code will appear in the display The error codes are listed below along with their possible causes and solutions The error code will be displayed for 2 5 seconds Error Display Cause Action Home Sensor Error when starting imprint Unplug the time recorder stamp and make sure that the carriage is not stuck or jammed Timing Sensor Error Also check to see that the ribbon cassette is Nor correctly inserted in place Unplug the clock Home Sensor Error when finishing imprint and plug it back in
33. ver if you find any errors or unclear passages please contact your local dealer CONTENTS GUIDELINES FOR SAFE OPERATION BEFORE YOU START Names and Functions of Parts erre 3 LCD Display es tre r reteset eet e tenet eee nn nn 4 Print Position Adjuster Slide Lever ppap 4 Functions of 5 control buttons a a Ge eee ee Ad tek Bese es a de 5 Removing the Cover Packing Material aa 5 USING THE TIME RECORDER STAMP Making a Test Print ttt ttt ee 6 Setting the TIN ttt ttt ttt es 6 Easy Way to Set the Time o 7 Setting the Date cc 7 Setting the Print Order co 8 Setting the Customized Comments lt 9 Setting the Layout of Customized Comments 10 Test Printing of Customized Comments aa 10 Changing the Print Position ttt ttt es 11 Setting the Print Pattern ee 11 Setting the Printing Length ee 13 Setting of Printing Activation Detecting Sensor 13 Setting the Number 14 Setting the Initial Number and Auto Reset 15 Setting the Repeat Times of Number aa 15 Setting the Daylight Saving Time ttt tte 16 Setting the Display and Password cr 17 Setting the Atomic Clock Germany UK and others 19 Setting the Time Zone US only Ba ay A a ee AD Dian ap a AN aw a e 20 INSTALLATION amp MAINTENANCE Wall Mounting in a a a e Ti a E A ia a ee me Se 21 Ribbon Cartridge Replacement E nm eee Sa pm a Ay ar Oa Gm Ra
34. while 1 is blinking 4 You will see the LinE1 1 display with En blinking LinE1 1 means the 1 character on Line 1 and En means the end of the sentence 5 Press the or button and select the character code referring to the Diagram of character code page 25 Press E button every time you confirm one character 6 Once you finish selecting the characters for line 1 press E Sa You will go back to P1 inPut CodE Display 4A 7 To enter the comments on Line 2 Press E and press when the line number is blinking You can program Line 3 by taking LinE 1 4 6F En the same steps 8 Once you finish programming Customized Comments press E and Go back to the P1 inPut CodE Display 9 Ifyou want to check the printing length press E button and select P 1 inPut C od E the line by pressing or button You will see the length in mm to the left of the blinking line number The sample display on the right shows that Line 1 is 35mm NOTE When the value exceeds the maximum length the error 05 will g Pran Lin E 3 D 1 appear on the display when you put the cover on Refer to page 22 NOTE You can choose the character font when programming the customized comments In order to make the imprint clearer we recommend you to use Two Byte Font Please refer to page 26 Diagram of Font O How to Correct Customized Comments How to Change the Font Use below