1.  non fulflment of the instruction  detailed for each device  maintenance and servicing carried out without the previous written consent of our  company  Moreover  warranty does not cover any damage due to wrong tension supply and any other  reason for which the manufacturer cannot be made responsible  Any device returned must be delivered to  our company with carriage paid and will be sent back with freight collect    Warranty validity ceases if customer   s payments are not fulflled  Each device manufactured by our company  meets the european safety standards    Our company declines all responsibility for the non observance of the safety rules by the installers   In order to reduce the time spent for servicing the returned items  all faulty materials which have been sent  back to us must be accompanied by the installer description of the item fault     u  Y Y    DEBMA        
2. COS   SAFETY EDGE  MECHANICAL MAGNETICAL             LPR   PROGRAMMING LED                                                               a es SEN ee 5  B ae ar LFCA   OPENING LIMITSWITCH  L   LFC C   CLOSING LIMITSWITCH  A  C  K  R OPEN CLOSE  E BUTTON BUTTON  D  B  R  O  W  N  COMEN   PHOTOCELLS  N C    OPENING  N C     s a ne     CLOSING  N C       Bava A     s _ 24Vac  LFCC Sem       p  see    AUTOMATIC  CLOSING  SETTING  MOTOR     _  TORQUE  FUSE    wo   lt  lt  PHOTOCELLS  pen 4A 1243444546171819  230V   MAINS  Ground wire    230V   NEUTRAL  BROWN OPEN  BLUE COMMON       BLACK    CLOSE        ga MOTOR    FLASHING LIGHT    CHARLY 230V CAPACITOR       PLEASE BRIDGE STOP  PHOTOCELLS AND SAFETY EDGE IF NOT CONNECTED    INSTALLATION REMARKS    The Mira L is a simple and innovative control unit that does not require  any programming for the work timing     Working times are set automatically when power is applied to the control  unit and after the first movements are performed     No special actions are required for installers and end users   The MIRA L is the first self programming control unit   In addition 4 switches are available to customize operations     The input of the mains voltage is protected against voltage surges and  the power supply line of the 24V accessories does not need fuses  because we have placed a thermal protection inside the transformer     If there is a shortcircuit on the 24V line the power LED goes off and if the  installer does not notice immediat
3. aa    74    DERMA          MIRA    ELECTRONIC CONTROL BOARD SUITABLE FOR  AUTOMATIONS WITH 1 MOTOR  WITH INPUTS FOR LIMIT SWITCHES       INSTALLATION AND USER MANUAL    Product designed and manufactured in Italy       CONFIGURATION WITH DIP 1 OFF LEDS    AP PP   OPEN OR STEP BY STEP    WARNING      CHECK ALWAYS THE CONNECTION TYPE   N C  NORMALLY CLOSED   N O   NORMALLY OPEN AND CH STOP   CLOSE OR STOP  THE CORRESPONDING WIRING FTC   PHOTOCELLS  COS   SAFETY EDGE  MECHANICAL MAGNETICAL ANTENNA L24 24V ACCESSORIES POWER SUPPLY  LIMITSWITCH LIMITSWITCH    230V   NEUTRAL             LPR   PROGRAMMING LED                                                                     im  LFC A   OPENING LIMITSWITCH  LFC C   CLOSING LIMITSWITCH  R KEYSWITCH START  E BUTTON STOP BUTTON  D  B  R  O  W  N Be  SWITCH OR AND  I KEYSWITCH N O   Ean   STOP  N C   3 PC common  COMMON   PHOTOCELLS  N C    OPENING NICE 5  SAFETY EDGE N C  e  CLOSING  N C     Gee COMMON    7  7 24Vac  877 24Vac SAFETY EDGE  AUTOMATIC  CLOSING  SETTING  MOTOR  gt   TORQUE    SETTING   d PHOTOCELLS  230V   MAINS  Ground wire    BROWN OPEN        BLUE COMMON       BLACK CLOSE      MOTOR    FLASHING LIGHT    CHARLY 230V CAPACITOR    PLEASE BRIDGE STOP  PHOTOCELLS AND SAFETY EDGE IF NOT CONNECTED    CONFIGURATION WITH DIP 1 ON LEDS    AP PP   OPEN OR STEP BY STEP  WARNINGI     CHECK ALWAYS THE CONNECTION TYPE   N C  NORMALLY CLOSED   N O   NORMALLY OPEN AND CH STOP   CLOSE OR STOP  THE CORRESPONDING WIRING FTC   PHOTOCELLS  
4. e for accessories   In case of a 24V line short circuit the corresponding led will be turned off  and the transformer automatic protection will safeguard the control unit  components  To restart the control unit remove the short circuit     WARNINGS       OUR COMPANY  AS MANUFACTURER  CAN NOT BE HELD RESPONSIBLE FOR DAMAGES DUE TO  WRONG OR MISSING CONNECTIONS OR DUE TO AN IMPROPER SETTING     THE SAFETY DEVICES SHOULD BE ALWAYS INSTALLED AND KEPT IN FULL WORKING ORDER     ONCE TERMINATED THE SYSTEM SETTING THE CONTAINER SHOULD BE PLACED BACK ON ITS  POSITION  FASTENING TIGHT ITS SCREWS     OUR COMPANY  AS MANUFACTURER  CAN NOT BE HELD RESPONSIBLE FOR DAMAGES DUE TO  IMPROPER USE OF THE DOORI GATE     IT IS FORBIDDEN TO REPLACE ANY ELECTRIC  ELECTRONIC OR MECHANIC PART WITH NOT ORIGINAL  SPARE PARTS     OUR COMPANY  HAS THE RIGHT TO MODIFY OR CHANGE THE ELECTRONIC BOARDS AND MANUALS   WITHOUT PRIOR NOTICE     ALWAYS REGULATE ACCURATELY THE TORQUE OF THE MOTORS  AN INCORRECT SETTING OF THE  TORQUE  MAY CAUSE DAMAGE TO PEOPLE  ANIMALS OR OBJECTS     WARRANTY    Devices and accessories are guaranteed for a period of 24 months after production  whose date is printed on  each item  The company will replace or repair its devices  provided that they are returned to our factory with  the warranty label in good conditions  In case of replacement of the returned items  these will remain  property of the company    The warranty does not include damages due to any incorrect use  such as 
5. ely the problem  the processor will  shutdown the control unit    After removing the short circuit the control unit will restart instantaneously  without damage and without replacing any fuses     The Mira L is designed to work with mechanical and electronic limit  switches and can not be used if there are no limit switches     WORK TIMING PROGRAMMING   Automatic  no action required by the installer or end user     To restore the factory setting  position the gate on the closing limit switch   turn power off  wait 5 seconds  then turn power on again     PROGRAMMING REMOTE CONTROL CODES   1  Press and release the button PPR  2  The programming LED starts flashing    3  Press the desired button on the remote control  repeat the operation  with all the remotes to store    4  Press the button PPR to exit the programming mode    Please note   If a code sent by the remote control already exists in memory it will be  deleted     After a few seconds the control unit will automatically exit programming     ERASING ALL REMOTE CONTROL CODES   To clear all the remote codes stored in memory press and hold the PPR  button until LED lights up again     PROGRAMMING THE MOTOR TORQUE    Turn trimmer 1 counterclockwise to increase the torque of the motor   Turn trimmer 1 in a clockwise direction to decrease the torque of the  motor     PROGRAMMING THE AUTOMATIC CLOSING TIME      Turn the trimmer 2 counterclockwise to increase the automatic closing  time    Turn trimmer 2 clockwise to decrease t
6. he automatic closing time or  remove it entirely    120   180 sec  60 70  0  30   sec  ar   a 10 85  15   sec  ac    240 OFF 100  5   Sec    AUTOMATIC CLOSING MOTOR TORQUE    CUSTOMIZATION WITH DIP SWITCHES     DIP 1  Operating logic  OFF  contacts 1 and 2 are working as STEP BY STEP  NO     and EMERGENCY STOP  NC     ON  The contacts 1 and 2 are working as OPEN  NO  and  CLOSE  NO     DIP 2  Remote control logic  OFF  The remote control works with STEP BY STEP logic     start stop     ON  The remote control works with CONDOMINIAL logic   executes only opening when fully open sends closing pulse     DIP 3  Activation inversion for brake  OFF  Inversion turned off    ON  The motor reverses the sens of rotation when it intercepts the  limit switches  it working as brake    DIP 4  Direction of travel    This dip changes the motor direction of travel and the limit switches    readings without physically having to exchange the electrical  connections     EXAMPLE     If your sliding gate should open to the right but with the standard wiring  instead moves to the left simply reverse the position of DIP from ON to  OFF or vice versa  It is not necessary to exchange the electrical  connections     The same principle explained in the above example also applies to doors  if the movements of opening   closing are reversed     SHORT CIRCUIT PROTECTION    In the control unit a fuse is present to protect the mains line input  230V    4A   there are no fuses for the protection of the 24V lin
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Insys GSM 4.2 I4  Xtech XTC-329 SATA cable  Vigo VGT371 Installation Guide  Operating instructions - Cary 100 Bio UV  SERVICE MANUAL, HEADSET TOP AND HEAD  Projector Specification PDF  DuPont™ Plas-Stick® Plastic  apoiada pela UML - liber  Melissa 635-071 User's Manual  /opt/pics/Contents/2008/10/10/2008101000080536    Copyright © All rights reserved. 