Home
Dokumentation - myIPE - IPETRONIK GmbH & Co. KG
Contents
1. Click OK to start the IPETRONIK CAN installation wizard 3 Welcome screen This is the first screen in the IPEmotion Plugin IPETRONIK CAN installation wizard Click Next to continue 4 Destination folder IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 13 27 IP TRONIK Due to the security model of Microsoft Corporation related to NET applications the installation of PEmotion Plugin IPETRONIK CAN a local drive is recommended According to the Microsoft conformance guidelines for Windows applications the files are installed to the default locations that are specific to the operating system and language Accept the default installation location for IPEmotion Plugln IPETRONIK To select another location click Change After you have specified the location for the installation click OK to return to the Destination folder screen Click Next to continue 5 Ready to install the program This screen indicates that IPEmotion Plugln IPETRONIK CAN is ready to install Click Install to start the installation 6 Installing A progress bar is shown during the installation process 7 InstallShiel Wizard Completed After the successful installation the following screen is shown Click Finish to exit the installation wizard A Windows Silent Setup cannot run other setups in silent mode the plugin must therefore be installed as silent too Setup IPEmotion Plugin IPETRONIK CAN exe S
2. 16 Ce E eleng Lee TREE mU 17 5 3 Defining OTT TEE TOES 18 54 lt 19 5 4 1 Devices of the component group Voltage current 19 IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 2 27 02 5 4 2 Devices of the component group 22 5 4 3 Devices of the component group 23 5 4 4 Devices of the component group 25 5 4 5 Devices of the component group TCGommumnicaton 26 5 4 6 Devices of the component group Multi devices 27 IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 3 27 memmen IPETRONIK 1 Important information Please follow these instructions before and during the use and application of any IPETRONIK product 1 1 Liability Warranty Copyright License agreement 1 1 1 Limitation of liability Any liability of IPETRONIK its representatives agents and the like especially with regard to personal injury or damage to property of any kind shall be excluded within the legally admissible framework as far as the instructions and warnings as mentioned below have not been followed 1 1 2 Warranty Products accessories and services have a 12 months warranty All product data specifications dra
3. v qn CAN Plugin setup copies CAN Server into Temp directory and installs CAN Server in Silent mode which must also be installed separately msiexec i IPETRONIK CAN Server msi gn 4 3 Uninstalling IPEmotion Plugin IPETRONIK The following chapter shows the deinstallation process of Plugin IPETRONIK CAN For removing IPEmotion Plugin IPETRONIK CAN you have two possibilities The option Remove of the IPEmotion Plugin IPETRONIK CAN installation program The option Add or Remove Programs for IPEmotion Plugln IPETRONIK CAN in the Control Panel IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 14 27 EL stig up and rene IP TRONIK With both methods you can remove files folders and registry entries from your computer which has been created during the installation Removing IPEmotion Plugin IPETRONIK CAN with the installation program To do so proceed as follows 1 Click in the menu Start on your computer on Settings and then Control Panel 2 Double click in the Control Panel on Add or Remove Programs 3 Select from the program list the entry IPEmotion Plugin IPETRONIK CAN and click Change to start the installation wizard Click Next to advance to the Program maintenance screen 4 Program maintenance This screen allows you to modify repair or remove IPEmotion Plugin IPETRONIK CAN Select Remove and click Next to continue 5 Remove the program This screen indicates that
4. and analyzing the acquired data 5 1 Defining general settings The main navigation tab Signals contains all available and connected systems with the respective type description and channels Click on the button Add system or Add component to expand the configuration by further systems or components IPEmotion Options e gt Plugins offers you the ability to define up to 4 interfaces for detecting Open the Options tab and activate the desired interfaces and the corresponding medium and CAN bus within the Hardware detection interfaces section v01 06 00 23144 Name Active Unit Phys Min Phys Max Sensor Min Sensor Max Sampling rate Name zi 1 d is gt 56199999 1 Y 100 000 100 000 100 100 1 Hz 56199999 56199999 2 Y 100 000 100 000 100 100 1 Hz 56199999_3 Y 100 000 100 000 100 100 1 Hz 56199999 4 Y 100 000 100 000 100 100 1 Hz Active Mame 1 Description System For CAN acquisition modules Reference IPETRONIK CAN 1 To define the general settings for the system properties proceed as follows Please find detailed information about the functionality and meaning of the following parameters in the IPETRONIK documentation IPEmotion General Select in the left tree view the desired system You can find the CAN hardware tab in the window of the configuration dialog You can set the following configuration definitions
5. contains information for installing and removing the software 2 2 Version 2 2 1 User manual IPEmotion Plugin IPETRONIK CAN This manual has the version number 01 06 2 2 2 PEmotion Plugin IPETRONIK CAN The descriptions in this documentation refer to the current release with the version number 01 06 2 2 3 IPEmotion The descriptions in this documentation refer to the current release with the version number 01 09 The Plugin requires at least IPEmotion 701 00 on your computer This icon indicates a useful tip that facilitates the application of the software Information This icon indicates additional information for a better o understanding IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 6 27 IPETRONIK error messages Attention This icon indicates important information to avoid potential 2 4 Support Headquarter IPETRONIK GmbH amp Co KG Im Rollfeld 28 76532 Baden Baden Germany Phone 49 72 21 99 22 0 Fax 49 72 21 99 22 100 info ipetronik com www ipetronik com Limited commercial partnership with its head office in Baden Baden registry court HRA No 201313 IPETRONIK Verwaltungs GmbH Baden Baden is individually liable society registry court Mannheim HRB No 202089 Management Erich Rudolf Andreas Wocke Technical support and product information www ipetronik com e mail support ipetronik com 2 5 Related documentations 2 5 1 IPEmotion The documentation IPEmo
6. of the inversion The inversion defines the acquisition range inversion of the input signal IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 22 27 IP TRONIK 5 4 3 Devices of the component group Pressure Working with IPEmotion Plugin IPETRONIK CAN Systems Name Active Unit PhysMin PhysMax SensorMin Sensor Max Sampling rate Mame Type 4 zen IPETRONIK 1 56199999 M SENS 3 51499999 SIM DMS 10 59599999 2 m 50 000 150 000 50 150 1 Hz 51299999 SIM SENS 10 51999999 SIM STG 8 50599999 SIM VIN 8 9 50299999 SIM VOLIT 8 4 Z4 IPETRONIK 2 290 ee 56399999 p THERMO 8 56099999 M THERMO 8 2 520899999 SIM PT100 10 General Format Scaling Display 9 57099999 SIM SBUS 240 d 53299999 SIM TH 8 8 E 53699999 SIM TH II 8N 8 Mame 59599999 1 wu 56099998 M THERMO 8 u 4 2 IPETRONIK 3 4 Description Analog acquisition input for pressure 59599998 CANpressure 2 4 zen IPETRONIK 4 10 ae 56299999 M FRQ 4 50499999 SIM CNT 6 To define the settings for the channel properties proceed as follows The respective available properties are defined depending on the selected device Please note that not all in the following listed tabs are available for each device Please find detailed information about the functionality and meaning of the following IPEmotion parameters in the IPETRONIK documentation IPEmotion General Format Scaling Display Select in the right window
7. your installation is now ready to remove Click Remove to start the removing process 6 Uninstalling A progress bar is shown during the uninstalling process 7 InstallShiel Wizard Completed This screen is shown after the successful deinstallation Click Finish to exit the installation wizard After removal IPEmotion Plugln IPETRONIK CAN is no longer indicated in the program list Removing IPEmotion Plugin IPETRONIK CAN with the deinstallation function of the Control Panel To do so proceed as follows 1 Click in the menu Start on your computer on Settings and then Control Panel 2 Double click in the Control Panel on Add or Remove Programs 3 Select from the program list the entry IPEmotion Plugin IPETRONIK CAN and click Remove to start the installation wizard 4 Click Yes to start the deinstallation 5 A progress bar is shown during the uninstalling process After the successful removal of IPEmotion Plugln IPETRONIK CAN the program has been removed from your computer and is no longer indicated in the program list IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 15 27 Ss Working with IPEmotion Plugin IPETRONIK CAN T RO N K 5 Working with IPEmotion Plugin IPETRONIK CAN The following chapter offers an overview of the available commands and their functions In addition it is shown how to use the IPETRONIK CAN devices and the software IPEmotion for configuring and acquiring data as well as managing
8. 0 00 60 1370 1 Hz 4 ig IPETRONIK 2 290 56399999 7 60 00 1370 00 60 1370 Hz a 56399999 8 Cl 60 00 1370 00 60 1370 1 Hz me 56099999 M THERMO 5089999 SIM PT100 10 General Format Scaling Display 57099999 SIM SBUS 240 23 g 53299999 SIM TH 1 8 8 53699999 SIM THII N 8 0881256339999 1 3 50199999 SIRE THERMO 8 Description Analog thermocouple acquisition input 4 IPETRONIK 3 4 59599999 CANpressure 2 we 59599998 CANpressure 2 4 2 IPETRONIK 4 10 Ww 56299999 M FRQ 4 50499999 SIM CNT 6 To define the settings for the channel properties proceed as follows Please note that not all in the following listed tabs are available for each device The respective available properties are defined depending on the selected device Please find detailed information about the functionality and meaning of the following IPEmotion parameters in the IPETRONIK documentation IPEmotion General Format Scaling Display Select in the right window of the channel view the desired channel You can find the Thermo tab in the window of the configuration dialog You have the ability to select the following properties Break detection Activate or deactivate the conductor break detection for identifying error status At a sensor break a defined value of 60 C is set re Averaging Activate or deactivate averaging the data for reducing the noise components in the signal The Mode tab offers settings
9. Fh Medium The medium defines the interface to the acquisition system The CAN medium already found by the driver is shown automatically ES CAN bus IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 16 27 Em Working with IPEmotion Plugin IPETRONIK CAN P T RO N The IPEmotion parameter CAN bus defines the CAN channel where the devices connected to and which is used by the devices for communicating Baud rate The baud rate defines the transfer rate which is valid for all system devices for communicating to the devices FE Device baud rate i Baud rate initialization Activate or deactivate the use of the baud rate at the interface initialization The Options tab offers the following configuration possibilities re Synchronized mode Activate or deactivate the use of the synchronized Free Running mode The Plugin defines a device as clock generator Master which sets the acquisition clock for all connected devices Slave All devices of an acquisition system have a synchronized internal clock ri Automatic CAN ID placing Activate or deactivate the automatic assigning of the CAN parameters TR Start CAN ID Define the start CAN ID for the automatic CAN ID assignation Names out of serial numbers Create the names of the devices and channels out of the serial numbers 5 2 The export function The CANdb export allows you to save the configuration in a CANdb description file If you want to cre
10. IK CAN 1 Sampling rate 1 define the general settings for the device properties proceed as follows Please find detailed information about the functionality and meaning of the following IPEmotion parameters in the IPETRONIK documentation IPEmotion General Select in the left tree view the desired device You can find the Extended tab in the window of the configuration dialog You have the ability to select the following properties Front number The front number defines the last digits of the device number It refers to the last five digits of the serial number by default The serial number is mandatory for detecting using and distinguishing the device from others within IPEmotion The serial number is composed of the front number and the device type and can generally be found at the back of the device or is detected automatically in IPEmotion di Clock The clock defines the acquisition clock by using an internal clock generator or another system device You can synchronize the data acquisition of the devices E Channel balance IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 18 27 Working with IPEmotion Plugin IPETRONIK CAN P T RO N K Activate or deactivate the offset compensation of the acquisition chain i e the initial excitation compensation at switching on Set the acquisition value to a defined value FR 29 bit identifier Activate or deactivate the extension of t
11. IP TRONIK Plugln Concept Open To Everything IPEmotion Plugin IPETRONIK CAN User manual May 2012 All rights reserved IP TRONIK Content OL OA EE 2 1 Important information 4 1 1 Liability Warranty Copyright License agreemenmt 4 IS ioo 4 a E 4 12 CODY MONT and Le E 4 1 1 4 Software license agreement 4 2 General information 2 21 1 6 2 1 EE 6 E CSO 6 2 2 1 User manual IPEmotion Plugin IPETRONIK CAN 6 2 2 2 PEmotion Plugin IPETRONIK CAN 6 229 NP Gu e e DE 6 2 3 Legend of the used ons 6 Ee EN 7 2 5 Related documentations 7 iS el cs un e e DEE 7 2 5 2 Manual MAL development 7 2 5 3 Engine compartment measurement 7 2 5 4 Vehicle 7 2 6 Documentation Teecdhack 8 Tee TT E 9 4 Setting up and removing 12 4 1 SE AR U un En E 12 M NN ge 5 12 d GR 12 4 2 Installing IPEmotion Plugin IPETRONIK CAN 13 4 3 Uninstalling IPEmotion Plugin IPETRONIK CAN 14 5 Working with IPEmotion Plugin IPETRONIK CAN 16 5 1 Defining general 0
12. N Plugin installation For working with the Plugin you need at least limited user s or default user s rights Vista IPEmotion Plugin CAN needs administrator rights during the The installation of IPEmotion Plugin IPETRONIK CAN is based on an installation wizard that guides you through the setup process step by step You can start the installation wizard from the USB flash drive or if you have downloaded the setup program from the IPEmotion forum at www ipemotion com from the setup file itself To install IPEmotion Plugin IPETRONIK CAN 1 Start the installation wizard from the USB flash drive or from the setup file USB flash drive Connect the USB flash drive to the USB port of your computer and follow the instructions of the installation wizard Setup file Browse the location of the setup file and double click IPEmotion Plugin IPETRONIK CAN exe to start the installation wizard Click Run to start the installation wizard Y Depending on the used PC operating system a security warning appears E 2 Setup language Setup Sprache Langue d installation Select the language for the installation process You can choose between the languages German Germany English USA and French France Setup language Setup Sprache Langue d installation E Select your language for this installation Wahlen Sie die ZA oo k Sprache dieser Installation Choisissez la langue d installation
13. SIM TH II 8N SIM PT100 SIM PT200 Sr Pressure CANpressure ABS 1 2 5 10 20 25 30 50 100 200 250 Bar CANpressure REL 1 2 5 10 20 25 30 50 100 200 250 Bar Counter frequency rc M FRQ SIM CNT Sr Communication Wer SIM ECU 552 553 554 SIM SER IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 10 27 s IPETRONIK P SIM ECU552 120 SIM ECU553 120 SIM ECU554 ECU e SIM SER 16 Multi devices MultiDAQ Each single device provides channels Please find detailed information about the M and SIM devices of IPETRONIK in the manuals Engine_Compart_Measurement and Vehicle_Measurement IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 11 27 Setting and removing P T RO N K 4 Setting up and removing 4 1 System requirements The minimum hardware and platform requirements for the application of the IPEmotion Plugin IPETRONIK CAN are outlined below 4 1 1 Hardware The minimum hardware requirements correspond to those of IPEmotion 4 1 2 Platforms The IPEmotion Plugin IPETRONIK CAN can be run under the following operating systems Windows XP 32 Bit Windows Vista 32 Bit IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 12 27 ES Ed Setting up and removing P T RO N 4 2 Installing IPEmotion Plugin IPETRONIK The following chapter guides you through the installation process of the IPETRONIK CA
14. ate a CANdb description file from the complete system you get a file in the ZIP format which includes all CANdb files of the devices Select the desired system and click on the Export t button or open the context menu with the right mouse button Select the signal export into a CANdb file or XML CANdb file IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 17 27 Working with IPEmotion Plugin IPETRONIK CAN P K P Dims Bie wi Project Signals Acquisition View Data manager Analysis Repo A Ka Add system Add components Export Check Adjustment Detect Configurati CANdb export Export of the system configuration inta VO1 06 00 23144 Kar 2 XMLCANdb export 4 ET Export of the system configuration into g an XML CAPMdb aid 56199999 The dialog window Save file as will be initialized Select the desired location and confirm with Save 5 3 Defining components v01 06 00 23144 Name Active Unit Phys Min Phys Max Sensor Min Sensor Max Sampling rate Name e 4 CAN 53 gt 56199999_1 m y 100 000 100 000 100 100 1Hz 56199999 2 1 V 100 000 100 000 100 100 1Hz 56199999 3 y 100 000 100 000 100 100 1Hz 56199999 4 y 100 000 100 000 100 100 1Hz General Extended Information Active Name 56199999 Description 4 analog acquisition inputs For tension power Reference 56199999 IPETRON
15. ction is strictly forbidden IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 4 27 IP TRONIK The following actions are allowed Installing and using a copy of the product a single computer or network This copy may only be used by a single user at a time If the product is to be used by multiple users an additional license will be required for each user Creating a copy of the product for filing or backup purposes Using a copy of the product on a home computer or on a portable computer provided that the copy is not installed at the same time also on your main computer Transferring the product to another person is only permitted if the license rights are also transferred and if the product and any copies created are completely deleted or erased including copies on hard drives and if the new owner agrees with the requirements of this license IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 5 27 seseo 2 General information 2 1 About this manual The manual PEmotion Plugin IPETRONIK CAN describes the structure of the Plugln and how to use the features for configuring devices which are based on the IPETRONIK CAN driver in IPEmotion taking acquisitions and managing and analyzing the resulting data Please read the manual PEmotion Plugin IPETRONIK CAN carefully to get to know the operating and to learn more about the functions and special features This manual also
16. ctions grammatical errors or information that require clarification Any suggestions for a general documentation improvement IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 8 27 s IPETRONIK 3 Introduction The IPETRONIK CAN Plugin offers you the ability to use M and SIM devices of IPETRONIK within IPEmotion The devices of the IPETRONIK CAN system are separated into groups according their functionality The current version supports the following four component groups Voltage current Temperature Pressure Counter frequency Communication Multi devices Each single group contains different devices which can be used for acquiring data Each device is an independent acquisition system and can be used as a stand alone devices as well as in combination with other devices in a CAN bus network The current IPEmotion Plugin IPETRONIK CAN version offers the following devices they are listed accordingly to the above classification VMoltage current a M SENS P M SENS DSP M SENS 8 a M SENS 8 DSP M SENS 8plus M SENS 8plus DSP P SIM SENS P SIM SENS DSP d SIM VIN SIM VOUT um SIM STG SIM DMS IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 9 27 Introduction IP TRONIK SIM DMS DSP Temperature rc Mc THERMO M THERMO M THERMO2 2 M THERMO 16 M THERMO T M THERMO T16 M RTD2 u THERMO SIM TH 11 8 SIM TH 11 16 SIM THERMO
17. dware filter and the averaging The hardware filter defines the anti aliasing filter for avoiding too high frequencies using the Adjust tab you can define the following settings ER Mode The mode defines the adjusting mode to be used Reference value The reference value defines the value which is recorded after an offset compensation Wr Offset value The offset value is only updated if the device is read with the Detect function TR Run channel calibration Start a channel calibration of one or several selected channels You have also the ability to calibrate with the context menu functionality Mark the desired system or the corresponding device and open the context menu with the right mouse button Select Extras and the desired calibration mode There are the following modes available IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 20 27 Working with IPEmotion Plugin IPETRONIK CAN P T RO N K Calibrate all channels Calibrate group Manual Calibrate group 1 Calibrate group 2 Calibrate group Calibrate group A Please note the following requirement to use this functionality The Allow accesses while configuring option must be activated IPEmotion options e Plugins gt Plugin specific options e Options gt Hardware accesses The Mode tab offers settings of the inversion The inversion defines the acquisition range inversion of the input signal By usi
18. els Calibrate group Manual Calibrate group 1 Calibrate group 2 Calibrate group 3 Calibrate group A Please note the following requirement to use this functionality The Allow accesses while configuring option must be activated options eo Plugins Plugin specific options eo Options Hardware accesses IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 24 27 Working with IPEmotion Plugin IPETRONIK P E T RO N 5 4 4 Devices of the component group Counter frequency v01 06 00 23144 Name Active Unit Phys Min Phys Max Sensor Min Sensor Max Sampling rate Name gt 5 m 4 ig IPETRONIK CAN 1 4 56299999_2 Hz 1 200000 1 200000 1 Hz 56299999 3 Hz 1 200000 1 200000 1 Hz 56299999 4 m Hz 1 200000 1 200000 1 Hz General Format Scaling Display Input signal Excitation Filter Sensor mode Mode Frequency Scaling calculator Sensor range Min 1 200000 Unit Hz Physical range Min 1 Max 200000 Unit Hz To define the settings for the channel properties proceed as follows Please note that not all in the following listed tabs are available for each device The respective available properties are defined depending on the selected device Please find detailed information about the functionality and meaning of the following IPEmotion parameters in the IPETRONIK documentation IPEmotion General Format Scaling Display Select
19. hat not all in the following listed tabs are available for each device The respective available properties are defined depending on the selectea device Please find detailed information about the functionality and meaning of the following IPEmotion parameters in the IPETRONIK documentation IPEmotion General Format Scaling Display Select in the right window of the channel view the desired channel You can find the Input signal tab in the window of the configuration dialog You have the ability to select the following properties FE Averaging Activate Deactivate averaging the values FE Break detection Activate Deactivate the conductor break detection IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 27 27
20. he address range from 11 bit to 29 bit ir Ignore the device Activate or deactivate this function to ignore single devices It is not necessary to delete the device from the configuration because it is not addressed at initializing This function allows you to ignore not available devices of a complex configuration without defining the configuration as invalid Further calculations or analyses include the corresponding NoValue The Information tab provides the information which was read by the device hardware YR Calibration date The calibration date shows the date of the last calibration ws Hardware version The hardware version shows the current hardware version of the devices wes Firmware version The firmware version shows the current firmware version of the devices 5 4 Defining channels 5 4 1 Devices of the component group Voltage current v01 06 00 23144 Name Active Unit Phys Min Phys Max Sensor Min Sensor Max Sampling rate Name zig An 6 56199999 2 Y 100 000 100 000 100 100 1 Hz 56199999_3 m V 100 000 100 000 100 100 1 Hz 56199999 4 O Y 100 000 100 000 100 100 1 Hz General Format Scaling Display Excitation Filter Adjustment Sensor mode Mode Yoltage including sensor excitation D Scaling calculator Sensor range Min 100 100 X Unit z Physical range Mi n 100 000 Max 100 000 Unit Y Selecting one or several channels is optically signalized and the corre
21. in the right window of the channel view the desired channel You can find the Input signal tab in the window of the configuration dialog You have the ability to select the following properties Threshold on Threshold on defines the value to detect the entry signal as active T Threshold off Threshold off defines the value to detect the entry signal as inactive Th Edge The edge defines the direction for detecting the pulse vr DC compensation Activate or deactivate the compensation of a direct voltage offset of the signal Gate time Define the time for recording the frequency IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 25 27 Working with IPEmotion Plugin IPETRONIK CAN P T RO N K We Minimal value The Excitation tab offers settings of the sensor excitation The sensor excitation defines the excitation for the respective connected channel using the Filter tab you have the ability to set the hardware filter The hardware filter defines the anti aliasing filter for avoiding too high frequencies The Mode tab offers settings of the inversion The inversion defines the acquisition range inversion of the input signal using the Analog output tab you can define the following settings ws Min Min defines the lower scaling limit of the analog excitation output Th Max Max defines the upper scaling limit of the analog excitation output 5 4 5 Devices of the component group Co
22. mmunication Systems SC m Mame Type C gt 4 Z4 IPETRONIK 1 Ab D SIM ECU CAN 55299999 2 CT SIM ECU CAN SIM ECU K LINE 0 General Format Scaling Display Mode Inverted To define the settings for the channel properties proceed as follows The respective available properties are defined depending on the selected Please note that not all in the following listed tabs are available for each device device following IPEmotion parameters in the IPETRONIK documentation Please find detailed information about the functionality and meaning of the IPEmotion General Format Scaling Display Select in the right window of the channel view the desired channel You can find the Mode tab in the window of the configuration dialog You have the ability to select the following properties T Inverted Activate Deactivate the inversion of the acquisition range of the entry signal IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 26 27 Working with IPEmotion Plugin IPETRONIK CAN P T RO N K 5 4 6 Devices of the component group Multi devices SD a Oe alt Active Unit Mame D Z 57799999 Em ge ws Channel 0 16 Sud dod O O ws Channel 1 16 LEE L ele Lae Pat ee EH Channel 3 8l 4 wu Channel 4 2 General Format Scaling Display Thermo Averaging Break detection Please note t
23. ng the CAN timeout tab you have the ability to select the following properties rs CAN timeout The CAN timeout defines the seconds to send an alternate value if no message is received on the CAN bus rs Output value The output value defines the alternate value to be send after a CAN timeout using the STG mode tab you can define the following settings TR Bridge You can define the following settings for the bridge Type Resistance Connection Define the bridge type the bridge resistance and the conductor count which are connected to the bridge at the entry FR Shuntcheck You can define the following settings for the Shuntcheck Resistance Quadrant Define the resistance value for checking the respective quadrant of the bridge and the bridge quadrant to be checked IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 21 27 Working with IPEmotion Plugin IPETRONIK CAN IP TRONIK 5 4 2 Devices of the component group Temperature systems Name Active Unit PhysMin PhysMax SensorMin Sensor Max Sampling rate Name Type zi m MEME gt 60 00 1370 00 60 tHe wd 56199999 M SENS 4 51499999 ae mm 56399999 2 O 60 00 1370 00 60 1370 1 Hz 51299999 EN m 56399999 3 60 00 1370 00 60 1370 1 Hz J 51999999 SIM STG 8 56399999 4 60 00 1370 00 60 1370 1 Hz 50599999 SIM VIM 8 56399999 5 lt 60 00 1370 00 60 1370 1 Hz 50299999 SIM VOUT 8 56399999_6 60 00 137
24. of the channel view the desired channel You can find the Filter tab in the window of the configuration dialog The tab offers the possibility to set the hardware and software filter and the averaging The hardware filter defines the anti aliasing filter for avoiding too high frequencies In addition the software filter offers the following definition possibilities FE Active Activate or deactivate the use of the software filter Wr Type The software filter type defines the filter characteristic Fe Frequency The frequency defines the limit frequency of the software filter using the Adjust tab you have the ability to select the following properties ES Mode IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 23 27 Working with IPEmotion Plugin IPETRONIK CAN P T RO N The mode defines the adjusting mode to be used Reference value The reference value defines the value which is recorded after an offset compensation Offset value The offset value is only updated if the device is read with the Detect function re Run channel calibration Start a channel calibration of one or several selected channels You have also the ability to calibrate with the context menu functionality Mark the desired system or the corresponding device and open the context menu with the right mouse button Select Extras and the desired calibration mode There are the following modes available Calibrate all chann
25. sponding LED is flashing at the connected device IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 19 27 Working with IPEmotion Plugin CAN P T RO N K Please note the following requirement to use this functionality The Allow accesses while configuring option must be activated IPEmotion options eo Plugins gt Plugin specific options e Options gt Hardware accesses To define the settings for the channel properties proceed as follows The respective available properties are defined depending on the selected Please note that not all in the following listed tabs are available for each device device Please find detailed information about the functionality and meaning of the lt gt following parameters the IPETRONIK documentation IPEmotion General Format Scaling Display Select in the right window of the channel view the desired channel You can find the Offset tab in the window of the configuration dialog You have the ability to define settings to the offset compensation An offset compensation defines the value compensation to a defined value for balancing an excitation offset This defined value has to be within the maximum admissible physical range The Excitation tab offers settings of the sensor excitation The sensor excitation defines the excitation for the respective connected channel The Filter tab offers the possibility to set the har
26. tion pdf provides you with a description and useful information related to IPEmotion This documentation is stored in the following standard language dependent directory C Programs IPETRONIK IPEmotion Vxx xx xx Help 2 5 2 Manual MAL development The documentation MAL development pdf provides you with a description and useful information related to the use of the interface with plug in components and IPEmotion 2 5 3 Engine compartment measurement The documentation Engine Compart Measurement pdf provides you with a description and useful information related to the IPETRONIK M devices 2 5 4 Vehicle measurement The documentation Vehicle Measurement pdf provides you with a description and useful information related to the IPETRONIK SIM devices IPEmotion Plugin IPETRONIK CAN IPETRONIK GmbH amp Co KG 7 27 IP TRONIK Please note that this documentation is currently only available in German 2 6 Documentation feedback At IPETRONIK the technical publications team strives to produce documentations of the highest quality and values your feedback as a reader and user If you have any comments or suggestions regarding our product manuals contact us under support ipetronik com Please inform us about the following points Version number Select Options Add Ins from the menu to display the version number Name of the guide Page number or section title Brief description of the content e g inaccurate instru
27. wings etc correspond to the current condition of the indicated creation date For the purpose of optimizing technical processes and production some details of our modules and accessory components may be modified at any time without prior notification Although the present document has been prepared with the utmost attention to detail it may not be exempt of misprints typing or transcription errors These errors are not covered by any warranty 1 1 3 Copyright and Duplication We reserve all rights in particular those of property copyright and trademarks The rights related to any third party trademarks mentioned in the present document remain unaffected This document may not be duplicated partially or entirely without the prior approval from IPETRONIK GmbH amp Co KG All graphics and explanations are copyright protected Any use beyond the scope of the document is prohibited 1 1 4 Software license agreement IMPORTANT THIS IS A LEGAL AGREEMENT BETWEEN YOU LICENSEE AND IPETRONIK GMBH amp CO KG IPETRONIK INC IPETRONIK BY CHECKING I ACCEPT ALL OF THE TERMS CONTAINED IN THE ABOVE AGREEMENT DURING INSTALLATION COPYING OR USING THIS PRODUCT IN ANY WAY YOU ACKNOWLEDGE THAT YOU HAVE READ THIS LICENSE AND THAT YOU UNDERSTAND AND EXPRESSLY AGREE TO BE BOUND BY THE TERMS AND CONDITIONS SET FORTH BELOW This software is property of IPETRONIK GmbH amp Co KG and is protected by copyright laws Its total or partial reprodu
Download Pdf Manuals
Related Search
Related Contents
APC-Sonde / APC probe / Sonde APC / Sonda APC / Sonda APC Intellian i6PE Installation and Operation Manual Copyright © All rights reserved.
Failed to retrieve file