Home

MR9L System Manual - Intelligent Home Online

image

Contents

1. Updated Please input M Code Save Video Entry System 14 9 Connect 4 Door stations with C5 MDS Optional The C5 MDS is designed for the C5 800 apartment intercom system to connect multiple Door stations Maximum 4 in one system P P IN OUT EXESES I A input of the 1st doorstation B input of the 2nd doorstation C input of the 3rd doorstation D input of the 4th doorstation or input of the Slave C5 MDS OUT output for the distributor IN reserved P Power negative input Ground P Power positive input 16 18V DC F3 Palo To connect the C5 MDS 3 steps must be done 1 Configure the Multi Door station Mode for each Door station 2 Enable the MDS function 3 Configure the monitoring time for each Door station 9 1 Configure the Multi Door station Mode When the Door station is standby press 48001 then input the D password 66666666 then you will Silo METAS ieo see Configuration menu Press 2 Js RERO to enter the Multi DS Mode item FP CORE PME on then input the number for the Door z Change admin code station and press ff to save the change then press to exit PE Ose Back Set to 1 in the first door station set to 2 in the second door station set to 3 in the third door station and so on 15 9 2
2. Video Door Entry System user manual eo Use Cat 5 Network Cable of 0508 Oe o This manual covers MR9L and MR9L ID Door station PRECAUTIONS Read this manual through before using the product Slots or openings in the back of the monitor are provided for ventilation and to ensure reliable operation of the video monitor or equipment and to protect if from overheating These openings must not be blocked or covered The monitor should never be placed near or over a radiator or heat register and should not be placed in a built in installation such as a bookcase unless proper ventilation is provided All parts should be protected from violence vibration And not allow be impacting knocking and dropping For clean the LCD screen using hands or wet cloth is forbidden Please do the cleanness with soft cotton cloth please do not use the organic or chemical clean impregnate If necessary please use pure water or dilute soap water to clean the dust Image distortion may occur if the video door phone is mounted too close to magnetic field e g Microwaves TV computer etc Please keep away the video door monitor from wet high temperature dust and caustic and oxidation gas in order to avoid any unpredictable damage Do NOT open the device in any condition call the administrator for help if there
3. door Screw cover Loudspeaker Camera Lens Night view LED LCD screen ID car window Digital Keypad Microphone 1 2 Open the Front Panel 1 Take off the screw cover 3 Take off the front panel 1 3 Mount the Door station Sr me SNP Cut a hole on the wall with the size of 345 H 115 W 38 D mm and wire the cable Put the mounting box into the hole and fix it with screws Connect all the cables and then fix the Door station body into the mounting box Fix the front panel on the Door station body Put back the screw cover on the top of the front panel N N N O990 a cti 90005 99099 2 Indoor Monitor 2 1 Parts and Functions CALL c UNLOCK C TALKMON IN USE o 2 2 Monitor Mounting 145 160 cm LCD Touch Screen Microphone CALL button UNLOCK button TALK MON button LED indicator Speaker Ventilation Vent Connection Port C5 MC connector Wire the system correctly see Connection chapter then hang the Monitor on the Mounting Bracket firmly 3 Distributor The Distributor is used to connect Monitors to the bus line One Distributor can connect 4 Monitors There are two mounting measures bar mounting or dirrect
4. C5 F4 Distributor E S ARIES TT Monitor C5 MDS The switch should be set to Master 4th 3rd 2nd 1st doorstation doorstation doorstation doorstation 217 10 Specifications Door station Power supply Camera Lens Power consumption Screen Video signal Distributor Power supply Power consumption Monitor Power supply for indoor monitor Power consumption Monitor screen Display Resolutions Video signal Wiring DC 15 18V supplied by PS2 1 3 inch color CCD Standby 0 5W Working status 15W 128 128 pixels LCD 1Vp p 750 CCIR standard DC 15 18V supplied by PS2 Standby 0 3W Working status 3W DC 15 18V supplied by system Standby 0 5W Working status 15W for kits 7 Inch color TFT LCD 1440 R G B x 234 pixels 1Vp p 750 CCIR standard Cat 5 network cable WARRANTY CARD NB Please keep this document safe as it is proof of your Warranty Your Video door system comes with a one year Manufacturers Warranty When used normally the following services are offered 1 Replacement for malfunctioning parts in first three months 2 Repair free of charge for malfunctioning parts in first year
5. if a Monitor is set to a code 0101 when the visitor press 0101 on the Door station only the Monitor with the code 0101 will ring 1 Power the monitor Enter into the Main setup installation input password 2412 to open the configuration page 2 Select and enter Flat Address item to modify the flat code 3 On the installation screen select Date and Time Set item to enter the time setting page use the touch screen to input the correct Time and Date 7 1 About Flat code The Flat Code also called monitor address is a unique code assigned to each monitor to identify different monitors each monitor has a unique flat code 7 2 About Debug Mode All settings can be changed by going into the Debug Mode gt gt DEBUG STATE lt lt Program Guide 0 Redial Last Nbrs 1 Download from PC 2 Debug Tools 9008 Options Volume Adjust Auto Dial Back d Display Net Data gt Display Alarm Guard Unit Online System Ready Video Entry System Video Entry System Debug State menu is now launched input 9008 then input the Admin Code 66666666 by default When Door Station is in standby press key When the screen is Debug State press 9009 to exit 7 3 About Default Set When the settings of the door station are significantly wrong the quickest way to solve the problem is to revert back to the default settings gt gt DEBUG STATE lt lt gt gt Program Guide lt
6. is any problem or mulfunction happens CONTENT 1 Door station 1 2 Indoor Monitor e gt 22d e is ii 3 3 Distributor e 99 002 RR NNE ENSE 4 4 Power Supply ue o e c n re mL 5 5 System Connection 6 6 Flat Code and Time Setting 7 7 Door station Configurations 8 8 Key Fob Settings only for MROL ID 13 9 Connect 4 Door stations with C5 MDS Optional 15 10 Specifications 18 1 Door station ge RF CARD o 1 1 Calling and Unlock Operation The MR9L Door station is a digital station with 128 128 pixels LCD screen color CCD camera night view LED and digital keypad Visitors can call the apartment by dial the Flat Code apartment number on the keypad If they don t know the Flat Code apartment number they can search the name list on the screen If the door station is in standby visitors need to press 9 to display the user name list Then using the 8 0 key scroll next last page Finally use the 1 to 7 key to call the desired flat Residents can open the door using their unique Unlock Code four digit PIN code If the door station is in standby mode press key then input the four digit PIN to open the
7. lt 1 Configuration 0 4 Redial Last Nbrs 1 4 Download from PC 2 4 Debug Tools Options Volume Adjust Auto Dial Back Unlock Setting Monitor Program Information Operating Options Access Security Card Management Net Address 001 Multi DS Mode 0 Unlock Timing 1 Monitoring Nbrs 2 Intercom Video 1 Camera Power On 0 Doorplate Mode 1 Display Net Data Display Alarm Guard Unit Online System Maintain Admin Code Advanced Config Press 1 9 to select Press 1 9 to select Back Back Video Entry System Video Entry System Video Entry System In Debug State press H In Program Guide press press 9 key then input key twice 1 key Admin Code and to confirm 7 4 Change Admin Code administrator password The Admin Code is the password to access the door station Debug Mode The default Admin Code is 66666666 Note that if the Default Set has been applied the Admin Code will also be set to default gt gt DEBUG STATE lt lt 1 Configuration 0 3 Redial Last Nbrs 1 Download from PC Unlock Setting 2 Debug Tools Monitor Program Options Information Volume Adjust Operating Options Net Address 001 Multi DS Mode 0 Unlock Timing 1 Monitoring Nbrs 2 Intercom Video 1 Camera Power On 0 Doorplate Mode 1 Auto Dial Back Access Security Display Net Data Card Management Display Alarm System Maintain Guard Unit Online Advanced Config De
8. Enable the MDS function When the Door station is standby press 48009 on the Door station Gr keypad then input the password the Z emade E 9 Advanced Config Voice Memo 0 default password is 66666666 the per I5 MMC 2 2 Advanced Configuration screen will F SR EE ERE en be displayed Press 5 to enter the e 29 Timing 30 Multi DS Mode item then input 2 Press 1 8 to select and press Z to enable the HMC Back function and the screen will back to Mee Video Entry System Advanced Config screen 9 3 Configure the monitoring time for each door station When on the Advanced Config screen press 5 to enter the HMC item press 4 and then press 4 key to enter the MR MDS screen The Addr item is for the C5 MDS setting if the current Door station is connected to the Master C5 MDS set the Addr to 1 if gt gt 9 5 gt gt 9 5 4 MR MDS Addr Chit Ch2T Ch3T Ch4T the current Door station is connected ei his to the Slave C5 MDS set the Addr to Video Entry System Video Entry System 2 The Ch1T Ch2T Ch3T and Ch4T is for the monitoring time seconds setting for each port If less than 4 door stations connected set to 0 for the ports that are not used Note that all the Door stations which are connected to the same C5 MDS should be have the same setting on the HMC item 16 9 4 System Connection AN Connect to next C5 F4 Monitor Monitor
9. The following actions will void the Warranty 1 Damage to the device during installation 2 Damage to the device through misuse 3 Opening and or disassembling the device 4 Attempting to force the device to perform functions for which it is not intended 5 Attaching the device to power supplies other than thoserecommended by the manufacturer Distributor for Warranty purposes Intelligent Home Online Ltd 62 Hartley Old Road Purley Surrey CR8 4HJ 44 0 20 86170015 www intelligenthomeonline com Product Purchaser Name Invoice N Purchase Date Il Intelligent Home MR9L CAT5 V2 2015 01 12 The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved
10. i GND AC AC Cables and distance Power supply cable RVVP 2 1 0 mm Distance from Door station to the last distributor 600 m Max Data Cable Catalogue 5 cable 0 5 mm or bigger Distance from Door station to the last Distributor 200m Max from Distributor to Monitor 30m Max 5 System Connection SOSS BR EA L L L L ML ML P P 2 ON Q90000 sm f l P P Lot OFF 18 V DC lock Power Supply Doorstation m C Doorstation Tone C Camera Tone C Guard unit Tone No Disturb Set instalation Gt Home Intellegent System Password ox Home Intellegent System C Alarm in out delay 40 a Date and Time set C Room Address C Other settings Informations Exit Home Intellegent System Home Intellegent System Every Monitor must be set to a Flat Code so that the Door station can identify the Monitor For example
11. brs Configuration 1 Download from PC Unlock Setting 2 Debug Tools Monitor Program Options Information Volume Adjust Operating Options Auto Dial Back Access Security Display Net Data Card Management Display Alarm System Maintain Guard Unit Online Press 120 to select Back Video Entry System Video Entry System In Debug State press H press 9 key twice There are 8 operating languages can be selected 0 Chinese 4 Spanish 1 English 5 German 2 French 6 Italian 3 Portuguese 7 Dutch 7 7 Change Ringtone There are 15 different ringtones as shown below gt gt DEBUG STATE lt lt gt gt Program Guide lt lt 0 Redial Last Nbrs Configuration 1 Download from PC Unlock Setting 2 Debug Tools Monitor Program Options Information Volume Adjust Operating Options Auto Dial Back Access Security Display Net Data Card Management Display Alarm System Maintain Guard Unit Online Press 1 9 to select Back Video Entry System Video Entry System 10 9 Advanced Config Tone Select mage Memo Voice Memo Name List ENS Monitor Version Call Mode Press 169 to select Back Video Entry System press 8 4 gt gt 9 8 Language Video Entry System Input the number for each language according to the language table press to confirm 9 Advanced Config Image Memo Voice Memo Name List gt HME Monitor Version Call Mode Language Press 1 9
12. em Video Entry System Video Entry System gt gt Online Searching lt lt Search Range input the Flat Codes and the end Flat codes The first two digits of the Flat Code are the floor number 0101 Online the last two digits are the Maximum flats quantity on each See floor For example input the range from 0101 to 0804 will 0104 Online i li search 8 floor and 4 flats on each floor You will see the id Se connection status of the selected apartments 0203 Online 0204 Linking Error 0301 Linking Error Back Video Entry System 12 8 Key Fob Settings only for MR9L ID This chapter explains how to configure the key fob function on MR9L ID Please note for the Door station without the Key Fob function the MR9L keep the settings by default The key fob is used to open the lock Total 500 key fobs can be registered with one Door station When swiping the fob on the fob reader on the Door station the distance must be less than 3 millimetres Key Fobs must be registered on the Door station Only then can fobs be recognised and open the door To use the key fobs 1 Enable the ID card key fob function 2 Register the Fobs 8 1 Enable the ID card key fob function When the Door station is in standby press gt 9008 gt Password 66666666 by default to get into the Debug Mode Menu as shown below gt gt DEBUG STATE lt lt 0 4 Redial Last Nbrs 1 4 Download from PC 2 4 Debug To
13. er Cards related to that Flat Code 13 When the Doors tation is standby press gt 9008 gt Password 66666666 by default to get into the Debug Mode Menu then Press gt 7 Card Management gt 1 Add Card to get into the Add Card page as shown below gt gt 71 1 gt gt 71 1 gt gt 71 1 Add Card Add Card Add Card 0101 Card 15977131 Updated Please input M Code Show the Card Back Save Video Entry System Entry System Show the card on the a Updated will show on the screen then show next card KS Flat Code is asked input the flat code 8 3 Delete User Cards Delete by Card Fob goto tt Program Guide gt 7 Card Management gt 2 Delete by Card to enter delete by card page as shown on the right then show the cards you want to delete Updated one by one gt gt 7 2 gt gt 7 2 Delete By Card Delete By Card M Code 0101 Show the Card Card 1382428255 Video Entry System leo Entry System Delete by Flat code goto Program Guide gt 7 Card Management gt 3 Delete by M Code to enter delete by flat code page as shown on the right then input the flat code to which the cards are related EN Updated will show on the screen EE if delete successfully Note that all 220 registered cards related to the flat 29 code will be deleted Sr EN gt gt 7 3 Delete By M Code Delete By M Code
14. fault Set Press 1 9 to select Back 1 9 to select Video Entry System Video Entry System Video Entry System In Debug State press key twice press 1 gt gt 1 8 Change Admin Code Input the new Admin Code and then press key to confirm ee RS Back Save Video Entry System 7 5 Change Unlock Code door open password There are two Unlock Codes which can be used The user can use either one of them to open the door They are 1111 and 2222 by default On the Debug State press to get into the Program Guide press 2 to open the Unlock Setting menu then enter 1 or 2 to change the Unlock Code as shown below gt gt DEBUG STATE lt lt gt gt Program Guide lt lt 2 Unlock Setting 0 Redial Last Nbrs 1 Configuration 1 4 Download from PC Unlock Code 2 2222 2 4 Debug Tools 3 Monitor Program Code Error Alert 0 4 Information Code Mode 1 Volume Adjust 5 Operating Options Code Range Auto Dial Back 6 Access Security Code Check lt gt Display Net Data 7 Card Management Code Nbrs 0 lt gt Display Alarm 8 System Maintain Change Program Code lt gt Guard Unit Online 9 Advanced Config Press 1 9 to select Press 1 9 to select Back Back Video Entry System Video Entry System Video Entry System 7 6 Change Door station language gt gt DEBUG STATE lt lt gt gt Program Guide lt lt 0 4 Redial Last N
15. o Line 1 and the input mode will switch to ABC input mode automatically Line 2 is for the names that are too long for one line After the name has been input press to save Button 1 Switch the letter between capitalization and lowercase Button 2 A B C a b c Button 3 D E F d e f Button 4 G H I g h i Button 5 J K L j k I Button 6 M N O m n o Button 7 P Q R S p q r s Button 8 T U V t u v Button 9 W X Y Z w x y z Button Cancel Button 0 Space blank i S C U G 11 7 9 Using software Online Search is a very useful function that can help the installer to easily check the connectivity of all the Monitors Please note Online does not mean via the internet In Debug Mode press 2 to get into the Debug Tools press 5 to open the Online Search menu as shown below gt gt DEBUG STATE lt lt 0 Redial Last Nbrs 1 Download from PC 2 Debug Tools Options lt gt Volume Adjust lt gt Auto Dial Back lt gt Display Net Data lt gt Display Alarm gt gt Debug Tools lt lt 1 lt gt Volume Adjust 2 lt gt Auto Dial Back 3 lt gt Display Net 4 lt gt Display Alarm 6 Monitor Property 7 Voltage Measuring 8 Simulate Calling gt gt Online Searching lt lt Search Range lt gt Guard Unit Online Press 1 8 to select Back Search Video Entry Syst
16. ols Options Volume Adjust gt Auto Dial Back Display Net Data gt Display Alarm Guard Unit Online gt gt Program Guide lt lt 1 Configuration 2 Unlock Setting 3 Monitor Program 4 Information 5 Operating Options 7 Card Management 8 System Maintain 9 Advanced Config 6 Access Security Passive Address 1 3 ACS Address 121 Clock Unlock Verify 0 Press 1 9 to select Press 1 5 to select Back Back Press gt 1 gt 1 to get into the Access Function page and set the value to 1 the function is now enabled Note the 4 Clock item is for time setting which will display on the top of standby welcome screen clock function is only available for MR9L ID 8 2 Register the Key Fobs All the registered key fobs are called User Cards User Key Fobs New fobs cards need to be registered one by one to the Door station to become a User Card User Key Fob and every User Card User Key Fob is related to a certain Monitor Address Flat code Registered User Cards Key Fobs can be deleted from the Door station and once unregistered will not open the door anymore They can also be re registered again to become a valid User Card User Key Fob There are two ways to delete User Cards User Key Fobs 1 Delete by card show the unwanted card s when the Door station is in Delete Card Mode 2 Delete by Flat Code will delete all the registered Us
17. to select Back Video Entry System 7 8 Name List function The name list can be edited by using the digital keypad of the door station The input method is similar to mobile phones By default the name list function is ON gt gt DEBUG STATE lt lt 0 Redial Last Nbrs 1 Download from PC 2 Debug Tools Options Volume Adjust Auto Dial Back Display Net Data Display Alarm Guard Unit Online Video Entry System gt gt Program Guide lt lt Configuration Unlock Setting Monitor Program Information Operating Options Access Security Card Management System Maintain Press 1 9 to select Back Video Entry System 9 Advanced Config Tone Select Image Memo Voice Memo IMC Monitor Version Call Mode Admin Code Timing Press 1 69 to select Back Video Entry System To use the namelist function the Name List item must be set to 1 enable which is default gt gt 91 4 Name List Video Entry System Press 2 to enter gt gt 9 4 2 Name List 1 Add 2 Modify 3 Initialise Press 13 to select Back Save Video Entry System Press 1 to add new names press 2 to modify the existing names press 3 to initialise to default Add 008 Line 1 eu d Line 2 Video Entry System Flat code and Name input page The first 4 digits are for the Flat Code input the address of the flat After 4 digits have been input it will switch t
18. wall mounting esed udi eei e E i NU P P Trunk Bus D C B A EA CARA hk i C5 F4 distributor E l a E i A B CID port Connect to Monitors I3 ng Trunk Bus Bus cable input output Connect to last ba C5 F4 or doorstation and connect to next C5 F4 un L Power P Power negative input Ground P Power positive input 15 18V DC M1 PR j 1 32mm im E i o UO NEN A a Est m E E E EN al set to 120 for the last C5 F4 a b E on the building the others I 120 must be set to HI c e He ETC a ble 1 O 8 Dirrect wall mounting 4 Power Supply The system uses a PS 2 power supply It provides the power for the door station distributors monitors and electric lock The maximum numbers of monitors it can support is twenty If there are more than twenty monitors in the system an additional power supply is needed Each extra twenty monitors will require an additional PS 2 power supply E lock power off to unlock type 13 16V DC ML ML of door station P P of the door E lock power on to unlock type 18V DC station or distributor ON OFF LK TEST ja ojo cao c se SASASASS L L L L ML ML P P UNLOCKQ AC IN 18V OUT ON swi Lo OFF PTR1 13 15V OUT i fa oo N i i i i i

Download Pdf Manuals

image

Related Search

Related Contents

Geemarc AMPLI1100 Telephone User Manual  Custody Cells SOP`s - Matrix Cleaning Systems  Aerocool Gladiator  新潟胎内高原の水 エコアクア 秩父湧水 6.0年 5.0年 5.0年 5.0年 富士山  Manuel BS 2011 Saisie Agent charté    User Manual - Vitomax 200  Silvercrest Model KB-62 Floor Plan  Manuel d`utilisation  Haier Refrigerator HRF-663IRG User's Manual  