Home

MPP1700 Users Manual - Visionary Solutions

image

Contents

1. 17 on the chassis can be filled with any VSI blade product Slots 18 and 20 can be filled with power supplies At least one of the power supply slots must be filled and for dual redundant power supply support both power supply slots must be populated 1 2 1 MPP1700 Front Panel Slots U n Power Supply Slots Blade Slots 1 3 Rack Mounting the MPP1700 Warning Before installing the MPP1700 be sure to read the safety and equipment information contained in this chapter Caution Use proper electrostatic discharge ESD precautions when installing or removing the MPP1700 to avoid damaging the unit s circuitry The MPP1700 is designed to be mounted in a standard 19 inch rack and to be oriented such that the card insertion cabling and indicators are facing out the front of the rack Only the AC power connection is located on the back of the unit It will utilize 3U of rack space but space should be left above and below the unit for proper cooling See the sections that follow for cooling requirements and information on installing blanking panels In order to install the MP1700 on a 19 inch rack you will need four screws and a screwdriver 1 Locate the four holes two per bracket on the left and right mounting brackets attached to the front of the chassis 2 Lift the empty chassis and place it inside the rack The mounting brackets of the MPP1700 must remain on the outside
2. of the rack 3 Attach with screws and tighten to secure the unit 4 Connect the power cable to the rear of the unit A power switch is provided near the AC power connection so that it can be turned on when the unit is properly installed and ready for operation 1 4 Hardware Inventory Your MPP1700 will be shipped with one US IEC Power Cable and one RS 232 cable 1 5 Blade Installation and Removal Note Itis important that the module be properly aligned with the slot guides before it is inserted into the appropriate slot on the chassis It is recommended that the user s line of sight be level with the middle of the backplane in order to see both slot guides clearly Install a VSI blade into the chassis as follows Caution Use proper ESD precautions when installing or removing a VSI blade to avoid damaging the unit s circuitry 1 Slide the blade open end first into the desired slot on the chassis until it plugs into the connector located on the backplane at the rear of the unit 2 Use the bottom ejector handle to securely seat the blade into the chassis and to properly mate the rear connectors The handle should lock closed when properly inserted to secure the unit 3 Tighten the captive thumb screw located at the top of the blade to provide a more secure mounting 4 If desired an additional Phillips screw can be installed through the handle 5 The Status LED will blink once per second when the blade is
3. the blanking panel 1 8 Cooling The MPP1700 has top and bottom vents in its cover to allow for proper cooling These vents must be left unobstructed Airflow is directed out of the rear of the unit These fan ports must also be left unobstructed Inproper restriction of air flow could result in unit failure or reduced operational life Thermal management of the equipment rack must be properly handled to avoid possible problems 1 9 MPP1700 Safety and Compliance Rating Information A Caution 100 240V 50 60 Hz 3A Fuse Rating A Caution 250V 3 15A SlowBlow Fuse Replacement Caution A Caution For continued protection against fire replace fuse with same type and rating A Caution Double pole neutral fusing Safety Approvals UL Listed I T E E257717
4. Inc including but not limited to acts of nature improper installation misuse lack of proper maintenance accident voltage fluctuations and unauthorized repairs or modifications This warranty becomes void in the event serial numbers are altered defaced or removed Visionary Solutions Inc reserves the right to make changes in the design or make additions to or improvements upon this product without incurring obligations to install the same on products previously manufactured The foregoing warranty is in lieu of all other warranties expressed or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose Visionary Solutions Inc neither assumes nor authorizes any person to assume for it any other obligations or liabilities in connection with the sale of its products In no event shall Visionary Solutions Inc or its authorized resellers be liable for special or consequential damages arising from the use of its products or any delay in the performance of this warranty due to causes beyond its control IN THE U S A SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS AND OR THE EXCLUSION OR LIMITATION OF CONSEQUENTIAL DAMAGES SO THE PREVIOUSLY STATED LIMITATIONS ON IMPLIED WARRANTY AND CONSEQUENTIAL DAMAGES MAY NOT APPLY TO YOU Customer Obligations The original dated bill of sale should be retained as proof of purchase and must be presented to the Vis
5. MPP1700 User s Manual Z Th Seer La 4 Leas i H ty 2011 Visionary Solutions Inc All rights reserved Please visit the support section of our website at www vsicam com for manuals other documentation and software downloads Visionary Solutions Inc 2060 Alameda Padre Serra Suite 100 Santa Barbara CA 93103 T 805 845 8900 F 805 845 8889 www vsicam com July 10 2011 Revision 1 0 5 About This Guide VSI recommends that you download the most recent version of this Manual from www vsicam com Limited Liability In no event shall Visionary Solutions Inc be liable whether in contract tort or otherwise to OEM or Customers for a any damages resulting from loss of use data or profits howsoever arising hereunder in relation to or in connection with Visionary Solutions Inc Software b any special indirect incidental or consequential damages even if Visionary Solutions Inc has been advised of the possibility thereof Visionary Solutions Inc s total liability in contract tort or otherwise arising out of in connection with or in relation to the Software or otherwise under this Agreement shall be limited to the amount paid to Visionary Solutions Inc or and authorized Visionary Solutions Inc reseller for the Visionary Solutions Inc Software or Hardware for a Customer in the 12 month period immediately preceding the event which has given rise to the liability The contents of this document are subject to revision
6. ionary Solutions Inc or a Visionary Solutions Inc Authorized Service Center when this equipment is to be serviced under the provisions of this warranty The cost of transportation to and from the Authorized Service Center is the responsibility of the user How to Obtain Warranty Service Should this equipment require warranty service you may obtain specific information on how to obtain this service by directly contacting Visionary Solutions Inc or the reseller who sold you this equipment The MPP1700 User s Manual 1 1 The PSA200 The PSA200 power supply is an International AC input 100 240VAC 200 Watt unit provided for the MPP 1700 It complies with the compact PCI standard and is 3U high 8HP wide Power supplies can be inserted into slots 18 and 20 of the MPP1700 Operation requires only one power supply However using two power supplies provides redundant load sharing When two power supplies are installed they can be hot swapped without interruption to the system 1 1 1 PSA200 Front Panel Q PSA200 SF O O Fault Input OK Two LEDs are provided on the PSA200 1 The Input OK LED will illuminate green when the supply is properly installed power is applied and the system is operational 2 The Fault LED will illuminate red if a fault condition is detected 1 2 The MPP1700 The Media Processing Platform MPP 1700 is a high density rack mount blade chassis used in VSI IPTV applications Slots 1
7. op of the module to provide a more secure mounting If desired an additional Phillips screw can be installed through the injector handle The Input OK LED will illuminate green when the supply is properly installed power is applied and the system is operational The Fault LED will illuminate red if a fault condition is detected To remove a power supply 1 If tightened loosen the captive thumb screw at the top of the front module 2 If installed loosen the additional Phillips screw in the ejector handle 3 Press the red tab in the bottom injector ejector handle to unlock the module 4 Pull down on the handle and pull the module out of its slot away from the chassis 1 7 Installing Blanking Panels After all blade options have been installed all empty slots must be populated with blanking panels Install blanking panels as follows Warning Failure to populate empty slots with blanking panels will impede cooling and may cause the MPP1700 to overheat Failure to populate empty slots with blanking panels will also negatively effect EMC radiation and immunity Note Blanking panels are available to cover each of the unused blade slots A different panel is used to cover an unused power supply slot than for the blade slots Two standard blanking panels can be used to cover a power supply slot if desired 1 Place the blanking panel onto the face of the MPP1700 2 Tighten the two captive screws on the front of
8. properly installed powered and operational To remove a VSI blade 1 2 3 4 Loosen the mounting screw at the top of the blade If installed loosen the additional Phillips screw in the ejector handle Press the red tab on the bottom of the ejector handle to unlock the blade Pull down on the handle and pull the blade out of its slot away from the chassis 1 6 Power Supply Installation Warning Before installing the power supply be sure to read the safety and equipment information contained in this chapter Caution Use proper ESD precautions when installing or removing the power supply to avoid damaging the unit s circuitry Note Slots 18 and 20 can only be populated with a power supply module Note Itis important that the module be properly aligned with the slot guides before it is inserted into the appropriate slot on the chassis It is recommended that the user s line of sight be level with the middle of the backplane in order to see both slot guides clearly To install a power supply 1 Slide the module open end first into slot 18 or 20 on the chassis until it plugs into the power connector located on the backplane at the rear of the unit Use the bottom ejector handle to securely seat the module into the chassis and to properly mate the rear connectors The handle should lock closed when properly inserted to secure the unit Tighten the captive thumb screw located at the t
9. without notice due to continued progress in methodology design and manufacturing Visionary Solutions Inc shall have no liability for any error or damages of any kind resulting from the use of this document Trademark Acknowledgements All trademarks or registered trademarks are properties of their respective owners Visionary Solutions Inc Limited 12 Month MPP1700 Warranty We appreciate your purchase of this Visionary Solutions Inc product We feel confident that in normal use it will provide years of satisfactory performance Visionary Solutions Inc warrants to the original user that the video equipment supplied by us will be free of defects in materials and workmanship for a period of twelve 12 months from the date of purchase from Visionary Solutions Inc or an authorized reseller of Visionary Solutions Inc Visionary Solutions Inc s obligation under this warranty shall be to the repair including any necessary parts and the cost of labor connected therewith or at its option the exchange or the refund of the purchase price of any video equipment that is determined by us to have a manufacturing defect within the warranty period Replacement parts furnished in connection with this warranty shall be warranted for a period equal to the unexpired portion of the original equipment warranty Warranty Exclusions This warranty does not apply to repairs or replacements necessitated by any cause beyond the control of Visionary Solutions

Download Pdf Manuals