Home
Installation Manual - Suntrol® STD500LED ATTENTION
Contents
1. Maintenance e Check the display for a solid mount from time to time e Check the screwed fastenings for a tight fit from time to time e Use glass cleaner and soft tissue to clean any stains from the display Please read before use This unit contains sensitive electronic parts and must be protected from shock and sudden climate variations Take care when handling the large display and don t press against the housing We have tried to make this manual complete and correct If you find any mistakes please inform us To assure compatibility see manual of connecting device Use only original parts especially for the power supply unit Disconnect the power supply unit from the grid once you have finished work with the large display Power supply is for indoor use only Protect from high humidity condensation and high temperature This manual accompanies the product It contains important information how to install and handle the device Proper use of the Suntrol STD5OOLED The large display is intended to show the measured values of different types of data sources which are listed in the manual The SolarWorld warranty is null and void if the large display is not used in the intended manner 3 fiii V 0310SW 1 00 USA SOLARWORLD VY We turn sunlight into power Introduction Congratulations on your decision to purchase this large display Please read this manual before use We wish you success with your new di
2. Data Pin 2 of the display is connected to RS485 Pin 4 of the Suntrol STL At Suntrol STL 800 RS485 A or B can be used 2 4 1 Connection scheme Suntrol STL Hams B BB 8B Display connector RS 485 to the inverters Rel S485 RS485 422 Power Network A ieee ur 12V Power supply unit O T pa V 0310SW 1 00 USA SOLARWORLD Ney We turn sunlight into power 3 Configure the display with the push button Before finally closing the display housing the display must be configured The display is preconfigured but it may be necessary to make some adjustments to fit to the local situation The following settings can be done data source from where the display gets the data to show If the data source is an energy meter with impulse output there are two additional settings Starting value of the total energy kWh Impulse rate of the energy meter Impulse per kWh The configuration is done with the push button between connector 2 pin 4 and connector 3 pin 3 The duration of pressing the button decides the reaction of the display Duration Reaction Remark Short button press lt 1second Value of the changeable The increment appears position is incremented after releasing the button by 1 Long button press gt 1 5 second The changeable position Press button until the jumps to the next left decimal point jumps to position or save settings the next left position or display jumps to the next va
3. SOLARWORLD We turn sunlight into power Installation Manual Suntrol STDSOOLED Large Display Example pee eae aeons chat ae ee Bd E it fi Solar power system SOLARWORLD WY We turn sunlight into power Total energy j kWh CO reduction kg ATTENTION WHILE MOUNTING THE DISPLAY DO NOT PULL ON THE FRONT GLASS DO NOT MOUNT THE DISPLAY OVER PASSAGEWAYS OR PERSONS fiii V 0310SW 1 00 USA SOLARWORLD VY We turn sunlight into power II Safety instructions for the Suntrol large displays Please make sure to read and follow all safety instructions listed below when you install and use a Suntrol large display If you miss any important information from this safety instruction or the display manual stop working and contact SolarWorld If any of these safety instructions or the instructions in the display manual are ignored the installer will take full responsibility for the consequences INSTALLATION Mechanical parts Our displays are party based on safety glass panes this requires special precautions and the following rules to be observed NEVER MOUNT THE DISPLAY OVER PASSAGEWAYS I NEVER MOUNT THE DISPLAY WHERE FALLING PARTS COULD HARM HUMANS OR VALUABLES e The glass pane can break when hit hard or when the mounting screws have been over tightened or are not mounted perpendicular to the glass pane of the display In case of breaks the safety glass will shatter into
4. WORLD a We turn sunlight into power 2 3 Connecting the display to a Sunny Boy Control via RS 485 At connector 2 the Sunny Boy Control is connected via a shielded data cable Pin 1 Data of the display is connected to Pin 3 Data of COM 2 3 of the Sunny Boy Control Pin 2 Data of the display is connected to Pin 8 Data of COM 2 3 of the Sunny Boy Control The shield of the cable must be connected to O V socket 1 pin 1 of the display only Important note The Sunny Boy Control must be configured for using with the large display gt Setup Interfaces gt ext Display gt Interface COM2 or COM3 gt Type HvG Details see user manual Sunny Boy Control if there are any questions how to configure the Sunny Boy Control please call the SMA hotline 2 3 1 Connection scheme Display connector a Sunny Boy o Control o 2 Je COM2 3 RS 485 V 0310SW 1 00 USA SOLARWORLD Sa We turn sunlight into power 2 4 Connecting the display to a SolarWorld Suntrol STL via RS 485 Important hint The baud rate configured in the large display must be the same as the baud rate of the inverters This can be selected at the configuration of the display with the button see chapter 3 of the installation manual At connector 2 the Suntrol STL is connected via a shielded data cable in series with the inverters Data Pin 1 of the display is connected to RS485 Pin 1 of the Suntrol STL
5. for potential free close contacts of energy meters Ro 2 52 interface RS 485 interface All connections are described below but only use the description for the data source you want to use Connectors and pin definition 1 2 o 12 3 1234 123 4 At the upper side of the electronic board see picture page 6 are 3 clamp connectors with the following assignments Connector Function Definition 1 Power supply Pin1 OV Pin 2 not used Pin3 9VDC 01A 2 RS 232 interface Pin RxD Pin2 GND Pina TxD Pin4 DTR 3 RS 484 interface Pin Data Impulse input Pin2 Data potential free close contact Pin3 Impulse Pin4 Impulse fiii V 0310SW 1 00 USA SOLARWORLD Ney We turn sunlight into power Connecting the power supply unit The DC output open wires of the delivered power supply unit is connected at connector 1 If you have to lengthen the cable use a cable with a diameter of about 0 75 mm Please take care of the polarity After connecting the power supply unit and the data source see below to the large display the power supply unit must plugged into a 230 110 VAC outlet Please note that the power supply unit is for indoor use only 2 1 Connecting the display to an energy meter with impulse output At connector 3 the impulse output potential free close contact of the energy meter is connected by using a shielded cable Pin 3 Impulse of the display is connected to Impulse of t
6. he configuration is finished now The SolarWorld Suntrol baud rate must be configured as the data source After configuring the data source bAud appears in the upper display line In the middle display line the actual baud rate appears With short button presses the baud rate can be changed in fixed values If the necessary baud rate appears in the middle display line press and hold the button until the display makes a segment test in all display lines At energy meter with impulse output as data source now Strt appears in the upper display line Now the starting value of the total energy can be adjusted Short button press gt the value of the changeable position increases by 1 starting with the right position Important The value of the number changes after releasing the button Hint The value jumps after 9 back to O Long button press gt the decimal point jumps to the next left position and the next position can be adjusted Exception At the first right position no decimal point appears Important Press button until decimal point jumps to the next left position All 6 positions of the value must be adjusted otherwise the value will not be saved After adjusting all positions of the starting value press and hold the button again until PULS appears in the upper display line Now the adjustment of the impulses per kWh can be done The adjustment of the impulses per kWh is similar to the starting value of the tota
7. he energy meter Pin 4 Impulse of the display is connected to Impulse of the energy meter The shield of the cable must be connected to O V connector 1 pin 1 of the large display only At the side of the energy meter the shield must be unconnected The maximum possible cable length is about 328 ft 2 1 1 Connection scheme Display connector Energy meter Example Shield Power supply unit fiii V 0310SW 1 00 USA SOLARWORLD Ne We turn sunlight into power 2 2 Connecting the display to a Sunny Boy Control via RS 232 At connector 2 the Sunny Boy Control is connected via a shielded data cable Pin 1 RxD of the display is connected to Pin 3 TxD of COM 2 3 of the Sunny Boy Control Pin 2 GND of the display is connected to Pin 5 GND of COM 2 3 of the Sunny Boy Control The shield of the cable must be connected to O V socket 1 pin 1 of the display only The maximum possible cable length is 50 ft Important note The Sunny Boy Control must be configured for using with the large display gt Setup Interfaces gt ext Display gt Interface COM2 or COM3 gt Type HvG Details see user manual Sunny Boy Control if there are any questions how to configure the Sunny Boy Control please call the SMA hotline 2 2 1 Connection scheme Display connector max 15 meters sunny Boy Control COM2 3 RS 232 fiii V 0310SW 1 00 USA SOLAR
8. l energy All 5 positions of the value must be adjusted otherwise the value will not be saved After another long button press the adjustments will be saved and the display starts the normal measuring mode recognizable by a segment test in all display lines V 0310SW 1 00 USA 4 Technical data Number of values Display type Shown values Dimension Material Business temp Storage and transport temp Data sources Power supply Warranty Norm Changes in every kind possible printing mistakes possible Manufactor RiCo Electronic Design GbR Tel 0049 0 7651 5848 Germany Glasbergweg 7 info rico electronic de fiii SOLARWORLD Se We turn sunlight into power 3 7 segment LCD display with 25 mm digits reflective Watt 6 digits kWh 6 digits kg 6 digits ca 500 x 400 x 45 mm Safety glass ABS plastic 10 50 C 14 122 F 20 60 C 4 140 F Energy meters with impulse output potential free close contact SMA Control Control Light and Control Plus SolarWorld Suntrol STL Others on request External power supply unit Input 230 110 VAC Output to large display 9 VDC Never connect more than 12 VDC direct to the large display 2 years CE EN 61326 1 D 79822 Titisee Neustadt www rico electronic de
9. ls 500 amp 300 glass Hole center distance 446mm 7 1 0 ol SOLAR POWER 346 MM 9 fF ATTENTION DON T SCREW IT TOO TIGHT Warranty void if glass is broken Die Edelstahl Unterleg The stainless steel scheibe mu direkt auf gommet have to dem Abstandshalter positioniert werden be placed on the Die Scheibe sitzt dann distance piece leicht locker directly V 0310SW 1 00 USA SOLARWORLD a We turn sunlight into power View into the display with removed housing cover w Do not connect more than 12 VDC a a ans a 2 fe There is a push button between connector 2 pin 4 and connector 3 pin 3 mounted to configure the display see chapter 3 Connect the power supply wires and data lines as described in section 2 corresponding to the used data source Configure the push button as described in section 3 Remount the housing cover with 4 screws and close the nut from the cable fitting Take care that the housing screws and cable fitting nut are secure in order to ensure a waterproof fit Finally mount the large display with the 4 provided mounting screw sets and distance parts at the wall V 0310SW 1 00 USA SOLARWORLD a We turn sunlight into power 2 General connection description The display must be connected to the power supply unit and the device that provides data to the display data source The large display provides different inputs Impulse input
10. lue Configuration a While powering up the display press the button for configuration see picture on page 5 CFG appears in the upper display line b After releasing the button SrC appears in the upper display line c Inthe second display line the number of the current configured data source appears Now the needed data source can be configured Assignment of number to data source see table below Short button press gt the displayed number increases by 1 Important The value of the number changes after releasing the button Hint After 14 the value jumps back to 0 Long button press gt the selected data source will be saved fiii V 0310SW 1 00 USA SOLARWORLD VY We turn sunlight into power Important Press button until the display makes a display test in all display lines or Strt appears in the upper display line The numbers in the second display line are assigned to the following data sources O Energy meter with impulse output 6 RICO RS 485 1 Sunny Boy Control RS 232 7 CV 485 2 Sunny Boy Control RS 485 8 Power One Aurora inverter RS 485 3 MaxComm Basic MaxWeb RS 485 9 Solutronic inverter RS 232 4 Fronius DisplayCard Box RS 232 10 SolarWorld Suntrol STL RS 485 5 RICO RS 232 11 steca Tarcom RS 232 If energy meter with impulse output is selected as data source the starting value of the total energy kWh can be configured At Sunny Boy Control as data sources t
11. ng tool and hand tighten only do not torque higher than 3 Newton meters Use a Special adhesive to secure the screwed fastening Notice If you cant use the supplied mounting material ask a local expert for equivalent mounting material Using anything other than the original mounting material is not recommended and is done at the installers own risk e Any parts of the display that are secured with silicon or an adhesive must not be removed or demounted oe fiii V 0310SW 1 00 USA SOLARWORLD Ne We turn sunlight into power Electrical Parts 1 NEVER CONNECT AC VOLTAGES TO THE DISPLAY I NEVER CONNECT HIGHER VOLTAGES THAN 12 V DC TO THE DISPLAY I STUDY THE INSTALLATION MANUAL TO ENSURE A CORRECT ELECTRICAL CONNECTION I USE THE ORIGINAL POWERSUPPLY ONLY The power supply must be connected by a qualified electrician e Use the original power supply only Compare output voltage and current of the power supply with the values on the sticker at the back of the display and those in the installation manual Compare input voltage of the power supply with the standard in your country If you find any mismatch or don t understand parts of the wiring plan please stop the installation and contact Solar World e All electrical connection to the display is done with system clamps only Never use soldering material to establish a connection to any of the PCBs of the large display e Never replace any broken fuses
12. small fragments minimizing the risk to humans or valuables e Never mount the display where falling parts could damage humans or valuables Always make sure that the bearing background is solid enough to carry the display e Never mount the display over passageways and consider children who could for example hit their head on the edges of the display Choose your place of installation very careful and avoid highly frequented areas e The glass front is de burred by our supplier however the display may still cause injuries Please ensure that all individuals working with our displays wear gloves able to protect the skin from cuts while ensuring a good grip on the glass Wearing protective clothing and shoes is also strongly recommended At least two people are needed to install each display one to hold the display while the other secures the screws Displays must always be mounted with all 4 screws Be sure to use our supplied screws and fitting mounting material e Make sure to use the correct anchors which guarantee the screws have the best possible grip When using the provided mounting material use the fitting anchors with metric dimensions Also use a drill with metric dimensions Ensure that screws are perpendicular to the display s glass pane to avoid additional tension at its Surface e Use the plastic flat washers directly in the front and back of the glass to prevent damage Mount the stainless steel knobs with the correct fitti
13. splay Please contact us if you have any questions or you don t know exactly how to use the display Contents 1 MOUNTING the large display oe eeseesesssesseesneeseessessessnesssesucesscenesssccuscsucsusessesusssscsusesnccusesscsusesucsusssncensesseeuesuesusssnecaeessesueesnecueeaneeneenseeeseans 5 2 Generi lala cuel 2 ane ats old ann a a E Re rt omr rn Ren tier A tae Pirie EA ENEA ren Freee ret 7 2 1 Connecting The Gisplay 10 anenerey meter WITH Impulse OULD UL assistia 8 2 2 Connecting the display to a SUNNY Boy Control Via RS 232 wreeceesesseessesseesseesnesseesessesssesuessnesneessesseesecueesnecueeseeesessecneenenneenees 9 2 3 COnne ching The display Tord Sunny BOY COT OL Mia RA B5 ssena a a a E 10 2 4 Connecting th display toa SolarWorld Suntrol STL Vid RS 485 susssssersvesnvvanerncsanenerannneranitseransnatansdanseranraptiintsansanndenavanseanenys 11 3 Configure the display with the push button ssssssssssssssssssrssseesssssssssssssrrresteeessssssssssssrrretreeessnsssssssssrrrteteeeennsssssssssrrrtteeeeeeesssssss 12 4 les aig het eke E ee reese terre wer E E Te te A E E veer ten tier fern eer A ones err ee Femme r err en eer eres 14 p V 0310SW 1 00 USA SOLARWORLD Se We turn sunlight into power 1 Mounting the large display The large display is designed to be mounted on a wall or similar surface The large display is waterproof after correct mounting and is therefore for outdoor use Installation detai
Download Pdf Manuals
Related Search
Related Contents
SOP GYRE-007R Auxiliary Plant Operations (Gyre) Muse M-200 User's Manual UM10589 - NXP Semiconductors TABLE OF CONTENTS Manual FORTE 2011 PREMIERS SECOURS EN ÉQUIPE DE NIVEAU 1 INVERTEC 135S, 150S & 170S Kills 99.9%of - KellySolutions.com User`s Guide to Parssim1 - The Institute for Computational Copyright © All rights reserved.
Failed to retrieve file