S2000-PT User`s Manual

image

Contents

1. 25 Connecting sn O 26 Getting tc eet ee eee ree 26 AA 27 30 Network Controller Settings T 33 Adding the 2000 to the Configuration of the Network Controller 33 Creating Partitions 35 Adjusting the Network Controller for Receiving Control Commands 36 41 Inspecting Module s Operation Conditions rr 43 Testing the S2000 PT in Self Diagnostic Mode LEE ra sapin apte dede 43 Checking for Communication Conditions over RS 485 Interface 44 3 www bolid com 155 Testing the Button Reader lts LED 44 Trouble hOO1Ig PPP S 45 www bolid com S2000 PT General GENERAL 5 www bolid com O LI D Orion ISS The S2000 PT Extinguishing Control and Indicator Module hereinafter referred to as the module is designed to operate within Orion Integrated Security Systems as a device for remote managing a number up to ten of S2000 ASPT devices each assigned with a specific partition of the Orion system and managing a specific agent releasing application The module provides gt Light indication of sta
2. Devices Monitored Zones E Devices Monitored Zones Console Status Device Address 2 Type S2000 ASPT quar Device Address 3 Type S2000 PT Device Address 4 52000 Figure 10 3 In the Partitions Zones window select the proper 2000 which will be assigned to the created partition and drag and drop its descriptor to the upper window on the partition descriptor see Figure 11 All zones of the selected S2000 ASPT will be added to the partition 35 www bolid com 52000 52000 Console Programming Tool File Edit 52000 Options Language Service Pages Help Dc lt Go By Partitions Zones Orion ISS Inspector Partition Partitio s ns Partition 1 Sector 1 Status of the device with the address 2 Partition 1 Device 2 Loop 1 Partition 1 Detection Loop 1 E Device 2 Loop 2 Partition 1 Detection Loop 2 Device 2 Loop 3 Partition 1 Detection Loop 3 HUE Device 2 Loop 4 Partition 1 Door Sensor Device 2 Loop 5 Partition 1 Manual Call Points Device 2 Loop 6 Partition 1 Pressure Detector Device 2 Loop 7 Partition 1 Main Power Device 2 Loop 8 Partition 1 Backup Power Supply Fe Device 2 Loop 9 Partition 1 Automatics On Off Device 2 Loop 10 Partition 1 Current Device Mode Device 2 Loop 11 Partition 1 Remote Release C
3. Access Group 255 Device Control Max Authority 1 User 4 Key 2 1 User Figure 15 Number Code User Access Group BOL D Inspector Authenticator Parameter Value 4 2 1 User z T 2 05 0 5 Repeat steps 2 to 4 for all the user electronic keys which are to be enrolled 6 If users are to be allowed to control partitions without presenting iButtons register the built in password of the 52000 Add a new descriptor by clicking the button El and enter the access code of the S2000 PT to the Code field of the Inspector Authenticator window This code must be the same as the code programmed for the S2000 PN in its configuration see Section Module Settings Then enter the name or comment of this authenticator to the User field and assign the S2000 PT access code to the Access Group which in turns is assigned to partitions which will be controlled by users from the S2000 PT The type of the authenticator Password will be defined by the program automatically Rights of the module to control partitions are programmed by defining the list of the partitions allowed to be controlled by the S2000 PT in the network controller configuration To program control rights of the S2000 PT 1 Gotothe Device Rights page of the PProg by clicking the button 4 En 2 Inthe Partitions window select the partitions which are allowed to be controlled by use
4. Search 1 Y y 2000 2 05 52000 5 3 02 52000 1 01 52000 1 08 Figure 8 52000 52000 Console Programming Tool File Edit 52000 Options Language Service Pages D m gt wh cc amp Devices B Inspector Device BE Device Address 2 52000 5 Device Address 3 Device Address 3 Type S2000 PT T Type S2000 PT El Device Address 4 Type S2000 KPB Version 1 01 Description Search Pot 1 QQ Y 1 S2000 2 05 2 52000 3 02 3 S2000 PT 1 01 4 52000 1 08 Figure 9 You can add the 2000 to the 52000 configuration and set its parameters manually if the module is not connected to the console For doing so click on the Add button E enter the network address of the module in the Inspector Device window select its type S2000 PT from the dropdown list and specify the version number 1 01 www bolid com 34 S2000 PT Programming Creating Partitions 1 Go to the Partitions Zones page of the PProg using the button E 2 Create new partition by clicking the button El see Figure 10 52000 52000 Console Programming Tool File Edit 52000 Options Language Service Pages Help Dc gt BOLID Partitions Zones BM Inspector Partition EET Partition 1 Number 1 Description
5. and buttons of the console TESTING THE IBUTTON READER AND ITS LED 1 Disconnect the S2000M console from the RS 485 interface bus 2 Touch the reader by the iButton 3 reader LED shall flash www bolid com 44 S2000 PT TROUBLESHOOTING On starting the S2000 PT the READY LED turned on is not The READY LED flashes once per second The module is not found by the network controller Upon pushing one of the buttons AUTO or EXTINGUISHING nothing happens Maintenance Check if the power is supplied to the input power terminals of the 52000 Verify whether the module communicates with the network controller through the RS 485 bus correctly or not Ensure the lines A and B of the RS 485 bus are properly connected to the contact terminals of the S2000 PT swap them if necessary Verify whether the network address of the module is correct and change it if necessary Ensure the lines A and B of the RS 485 bus are properly connected to the contact terminals of the 52000 swap them if necessary Check if an access code is programmed for the module in its configuration see Section Module Settings If so check if this access code is enrolled as a password in the network controller configuration and assigned to an access group with the relevant control rights If otherwise no access code if programmed and users are allowed to control partitions only by presenting their electronic keys to the
6. see Section n case of loss of the communications over the RS 485 interface within 15 to 30 seconds READY starts flashing twice per second provided that the input power is in norm The LED stop flashing and returns to steady lighting after restoring communications Light Indication of Partition Statuses In such cases when permission to control an S2000 ASPT device from the S2000 PT is granted the AUTO and EXTINGUISHING buttons operates as follows To activate the automatic mode Push the AUTO button if the relevant LED is turned off of releasing extinguishing agent To disable the automatic mode of Push the AUTO button if the relevant LED is turned on releasing extinguishing agent the manual mode only To release extinguishing agent Push the EXTINGUISHING button for more than 3 s To cancel releasing Push the EXTINGUISHING button shortly within 0 2 s to 1 s Pushing an AUTO button of the S2000 PT entails giving the relevant 2000 a command for changing the current mode of starting the connected fixed extinguishing system If the automatic mode starting on receiving responses from fire detectors is in force this mode will be switched to the manual mode starting on pressing a manual call point or receiving the relevant command from the network controller and vice versa Pushing an EXTINGUISHING button of the S2000 PT entails giving the relevant S2000 ASPT a command to start releasing extinguishing agent or to ab
7. the Orion system UPpog exe of versions 4 0 0 825 and above must be run on this computer After running the UProg its working window is opened on the PC display At the top part of the window there are the Main Menu and the Toolbar Select the Device gt Read Device Configuration command Serial Port Address 1 52000 2 05 Address 2 S2000 ASPT ver 3 02 Address 3 52000 ver 1 01 Address 4 S2000 KPB ver 1 08 Select Stop Cancel Figure 4 The window for searching devices will be output on the display Specify the number of the logic COM port the S2000 PT is connected to and the UProg will start searching the devices connected to this COM port of the PC see Figure 4 As a result of this searching list of all found devices with their network addresses and version numbers will be shown at the display see Figure 5 Search Devices Serial Port 1 52000 ver 2 05 2 2000 ASPT ver 3 02 3 2000 PT ver 1 01 4 S2000 KPB ver 1 08 Select Search Cancel Figure 5 www bolid com 28 S2000 PT Proqramminq Select the entry for the S2000 PT by left mouse clicking and then click the Select button The UProg will display the window with current settings of the S2000 PT see Figure 6 After opening the window with settings the S2000 PT module enters the programming mode with its READY LED flashing 4 times per second UPROG Address 3 52000 ver 1 01 BAR Fie Device H
8. Code of the S2000 PT or with user authenticators entering presenting which will be considered by the network controller as an authorized command to get access to partition control For doing so 1 Goto the Authenticator page of the PProg clicking on m 2 Create a new descriptor clicking the button El see Figure 14 2000 S2000M Console Programming Tool File Edit 52000 Options Language Service Pages Help D c gt amp Mh Authenticators Bi XS Z Inspector Authenticator Password 1234 Zone Control 255 Device Control Max Authority Code Key User Access Group Unspecified TAA Figure 14 3 Enroll the first user iButton For doing so click on the Read Key button and select the system reader the iButton will be touched to Then touch the access device to the reader The code of the device shall be shown in the Code field see Figure 15 4 Enter the user name and assign the authenticator to the proper Access Group in the Inspector Authenticator window The type of the authenticator Key shall be defined by the program automatically www bolid com 38 S2000 PT Programmin 52000 52000M Console Programming Tool D oc E File Edit 52000 Options Language Service Pages Help hay Authenticators B b 1 Main Password 123456 2 Password 1234 3 Password 0001 Programming Zone Control 1
9. Mode all LEDs are on Pre Operation Time External Reader Output Interface Reader LED Operating Temperatures www bolid com Orion ISS 10 10 strings of five LEDs each to indicate statuses of 10 related partitions 7 LEDs to indicate alarms and troubles in all related partitions READY LED to indicate statuses of the S2000 PT itself Built in Built in 16 events Yes 9600 Bd Half duplex External 12 V to 24 V Bolid manufactured RIP 12 or RIP 24 battery backed power supplies are advisable 10 2 28 4 V dc 3 W max 250 mA max 12 V 130 mA max 24 V 30 mA max 12 V 20 mA max 24 V 2 s max One Reader Input to connect an external iButton reader Touch Memory 1 Wire u LAN One LED controlled by logical 5 V CMOS levels with current values being restricted by 10 mA at direct connection 30 C to 50 C S2000 PT Specifications gt v v WV Ingress Protection Rating Overall Dimensions Weight Average Lifetime Device Programming Connection to a PC IP20 170 mm x 340 mm x 25 5 mm 0 6 kg 10 years By means of the UProg exe the tool for configuring devices of an Orion system Over the RS 485 interface bus via one of the Bolid manufactured interface converters PI GR 52000 S2000 USB USB RS485 11 www bolid com 155 www bolid com 12 S2000 PT Operation Principles OPERATION PRINCIPLES 13 www bolid com O L I D Orion 1
10. Section Agent Release Control Lit steady in green Off Each EXTINGUISHING LED indicates various steps of operating of the agent releasing application related to this indicator string EXTINGUISHING button has just been pushed Pre discharge Delay Release Release Fault Agent is being released Releasing cancelled Quiescent Mode Flashes in green and red alternately twice per second until the relevant command is executed or rejected see Section Agent Release Control Flashes in red once per two seconds Flashes in red twice per second Flashes in yellow once per second Lit steady in red Off Off Light Indication of Alarms and Troubles in Partitions Summarized statuses of all the partition assigned to the module are showed by alarm indicators FIRE and PREALARM as well as by trouble indicators LOOP OUTPUT POWER COMMUNICATION and TAMPERING at the right part of the S2000 PT The summarizing indicator FIRE indicates presence of a fire in one or more partitions related to the module by flashing in red once per second The summarizing indicator PREALARM is turned on flashes in red once per two seconds if one or more of the partitions related to the module have entered the Prealarm status Indicator of TROUBLE group at the right part of the module flashes in yellow once per two seconds if there is a relevant trouble in one or more partitions LOOP Trouble of the alarm loop of an S2000 ASPT OUTPUT Trouble of the rel
11. located at a place protected against unauthorized access The password or PIN code or access code is programmed in the configuration of the S2000 PT using the UProg exe see Section Module Settings This password shall also be enrolled in the configuration of the network controller with relevant rights to control relevant partitions see Section Adjusting the Network Controller for Receiving Control Commands In case of user s touching his iButton to the S2000 PT reader the module sends the code of the iButton to the network controller over the RS 485 interface The network controller verifies the received code the module sounder being activated for 0 25 s and the module LED flashing 2 times per second If the presented iButton is enrolled in the network controller configuration then the Access Granted signal sounds and the module LED is lit steady for 30 seconds After that the user can control partitions by using AUTO and EXTINGUISHING buttons within 30 seconds On user s pressing a button the module sends the network controller the request for executing the relevant control command turning on off the automatic mode of releasing extinguishing agent or remote release cancel releasing extinguishing agent The network controller considers the received request and makes an access decision If the electronic key has all the required access rights the network controller transfer the control command to the relevant S2000 ASPT see below
12. module reader then check if the relevant keys are programmed with the relevant rights in the network controller configuration see Section Adjusting the Network Controller for Receiving Control Commands Check if the module itself is allowed to control partitions in the network controller configuration see Section Adjusting the Network Controller for Receiving Control Commands Amend the module or the network controller settings if necessary 45 www bolid com BOLID ONE YEAR LIMITED WARRANTY Bolid Company and its divisions and subsidiaries Seller 4 Pionerskaya Str Korolev 141070 Moscow Region Russia warrants its security equipment the product to be free from defects in materials and workmanship for one year from date of original purchase under normal use and service Seller s obligation is limited to repairing or replacing at its option free of charge for parts or labor any product proven to be defective in materials or workmanship under normal use and service Seller is not responsible for results where the product is used improperly where it is used for any application it is not intended for used under unacceptable environmental conditions and mishandled or stored under improperly Seller shall have no obligation under this warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other than the Seller In case of defect contact the security professional who installed and maintains your
13. security equipment or the Seller for product repair This one year Limited Warranty is in lieu of all other express warranties obligations or liabilities THERE ARE NO EXPRESS WARRANTIES WHICH EXTEND BEYOND THE FACE HEREOF ANY IMPLIED WARRANTIES OBLIGATIONS OR LIABILITIES MADE BY SELLER IN CONNECTION WITH THIS PRODUCT INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE ARE LIMITED IN DURATION TO A PERIOD OF ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE ANY ACTION FOR BREACH OF ANY WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY MUST BE BROUGHT WITHIN 12 MONTHS FROM DATE OF ORIGINAL PURCHASE IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Some countries do not allow limitation on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Seller does not represent that the product may not be compromised or circumvented that the product will prevent any personal injury or property loss by burglary robbery fire or otherwise or that the product will in all cases provide adequate warning or protection Buyer understands that a properly install
14. 016 with wall plugs Note Access devices DS1990A and a reader such as Schityvatel 3 or similar should be ordered and supplied separately SAFETY PRECAUTIONS There are no potential hazard circuits within the module Do SHUT OFF the power from the module before mounting wiring or maintaining the S2000 PT Mounting and maintenance the S2000 PT must be performed by qualified engineers S2000 PT MOUNTING Figure 2 display the appearance of the module as well as its overall and mounting dimensions The S2000 PT is to be attached to walls or any other structures near the operator s location in premises protected against atmospheric fallouts and mechanical Mount the module and its connecting lines in accordance with the Wiring Diagram see Figure 9 Attach the module at the height of 1 5 meters above the floor www bolid com 24 S2000 PT Installation mama READY Bo clo orn m o Bo cll oworr E ON oFF TROUBLE E 04 oWo O5 m ON OFF O OUTPUT ONOFF O POWER oT m oN m ON OFF COMMUNICATI
15. 55 INDICATION The S2000 PT module is equipped with 50 LEDs indicator strings 1 to 107 to indicate statuses of ten related partitions the READY LED to indicate statuses of the module itself and 7 LEDs to represent alarms and troubles of various types which are happening in the part of the system related to the S2000 PT at the time In addition the S2000 PT is equipped with a sounder and can issue various audible signals for various events The partitions which statuses are indicated by the S2000 PT should be formed by a System Administrator the descriptors of the partitions should be added to the network controller configuration and the numbers of these partitions should be linked to the relevant indicator strings 1 to 10 in the 2000 configuration see Section Module Settings If a reader is connected to the module then the reader LED indicates user to system interaction on user s requesting access to control releasing extinguishing agent by S2000 PT buttons Light Indication of Module Statuses Operating conditions of the module S2000 PT are indicated by the green LED READY as follows Norm quiescent mode On No communication over the RS 485 interface Flashes twice per second Programming Flashes four times per second In case of loss of the communications over the RS 485 interface within 15 to 30 seconds READY starts flashing twice per second provided that the input power is in norm The LED stop
16. Columns of indicators 1 to 10 are turned on one by one red and then one by one in green 2 Strings of indicators 1 to 10 are turned on one by one in red and then one by one in green 3 All status indicators and single color indicators are turned on together status indicators being kit in red 4 status indicators and single color indicators are turned on together status indicators being kit in green 5 single color indicators FIRE COMMUNICATION and OUTPUT flash On pressing on an AUTO or EXTINGUISHING button the relevant LED is turned on L Here shortly means keeping the button pressed for 0 1 to 0 5 s while long means keeping the button pressed for at least 1 5 s Pauses between pushing shall be 0 2 to 1 s 43 www bolid com O L I D Orion 155 The S2000 PT exits the self diagnostic mode automatically after 10 s since last pushing an AUTO or EXTINGUISHING button or on pressing the SILENCE button CHECKING FOR COMMUNICATION CONDITIONS OVER THE RS 485 INTERFACE 1 Connect wires of the RS 485 bus to the S2000M console Apply power to the S2000 PT module and S2000M console The READY LED shall be lit steady in green gt m Within minute since powering the console shall display messages about founding and resetting the device with the network address of the S2000 PT If several messages are received which were collected in the module buffer they can be listed by
17. ON 08 ON OFF TAMPERING iq 09 B D DNOER SILENCE x O10 o cgo S2000 PT SoU H 340 L 334 260 255 O E O SE e 37 310 Figure 2 Overall and Mounting Dimensions of the S2000 PT WIRING THE RS 485 INTERFACE LINE Connect RS 485 interface lines as shown in the electric wiring diagram below see Figure 3 2000 Touch Memory reader Figure 3 Wiring Diagram for S2000 PT Operating 25 www bolid com O L I D Orion 155 To connect the module to the network controller via the RS 485 interface bus attach its RS 485A and RS 485B terminals to the A and B lines of RS 485 bus respectively Wires are connected to the S2000 PT by means of its screw terminal block The maximum wire cross section area is 1 5 square millimeters If the module is neither the first nor the last device within the RS 485 bus remove the jumper set on the module PCB near the RS 485A and RS 485B terminals WARNING If the RS 485 interface bus is quite long more than 1000 meters use twisted pair cabling to connect the devices The resistance value of each RS 485 interface line A or B measured between the network controller and the most distant device MUST NOT exceed 2000 While wiring the RS 485 interface bus you are advised to configure the device network as the bus that is connect devices in a chain If a long distance branch more than 50 meters from the
18. Orion ISS EXTINGUISHING READY FIRE PREALARM TROUBLE Loop Power communication TAMPERING SILENCE S2000 PT BOLID gt m Control and Indicator Module S2000 PT User s Manual This User s Manual is intended to help for studying operability principles and maintenance of the S2000 PT Extinguishing Control and Indicator Module of version 1 01 Please read the instructions completely before connecting operating adjusting or maintaining this product The following terms are used throughout the Manual Alarm Loop or Loop or LP The electrical circuit with non addressable fire or intrusion detectors or other non addressable devices included Actuation of a single detector brought in an alarm loop causes breaking of the loop as a whole so the actuated detector can be located only with the accuracy of the alarm loop Zone A minimal part of a security and safety installation that can be monitored and controlled independently Depending on the context the term zone can imply an alarm loop an addressable detector a hardwire component etc Partition A set of zones that can be user controlled as a whole As a rule zones fall into partitions depending on their location e g one partition can involve all zones at one indivi
19. RS 485 bus needs to be made an S2000 PI interface repeater produced by the Bolid Company is to be included at the cross point The number of successively included repeaters is not restricted CONNECTING A POWER SUPPLY Connect a power supply of 10 V to 28 V to the 3 and 4 terminals of the module see Figure 3 We recommend you to use Bolid manufactured power supplies of RIP series Couple the 0 V circuits of the S2000 PT and the network controller If both the devices are connected to a single power supplies their 0 V circuits need not be coupled GETTING STARTED After mounting the S2000 PT and its connecting lines turn the module s power supply on The READY LED of the module shall light in green S2000 PT to work as a part of an Orion system under control of a network controller it must be assigned to a unique network address see Section Module Settings www bolid com 26 S2000 PT Programming PROGRAMMING 27 www bolid com 155 program S2000 PT module for operating your specific functions give change settings of the configuration parameters stored in its non volatile memory by doing the following Connect the module to a computer via one of the Bolid manufactured interface converters such as PI GR 52000 S2000 USB or USB RS485 or through the S2000M console which should be switched to the programmed mode as described in its Manual The tool for configuring the devices of
20. and then returns the module the result of the operation via the RS 485 interface If the iButton is not registered by the network controller then touching it to the module reader causes issuing the Code sound and the module LED is turned off www bolid com 18 S2000 PT Operation Principles If presenting electronic keys is not needed for controlling partitions then on pressing one of the buttons AUTO or EXTINGUISHING the S2000 PT sends the network controller over the RS 485 the relevant request and its build in password access code The network controller considers the received request and makes an access decision If the module access code is enrolled in the configuration of the network controller see Section Adjusting the Network Controller for Receiving Control Commands and have rights for the requested operation then the network controller sends the relevant executive command to the S2000 ASPT related to the pressed button see below and then returns the S2000 PT the result of operation over the RS 485 interface If otherwise the access code of the S2000 PT is not written in the configuration of the network controller the Illegal Code signal sounds If the module password is enrolled in the network controller configuration but have no rights to control releasing extinguishing agent then user s pressing on an AUTO or EXTINGUISHING button causes the LED adjacent to the button to flash until the requested command is rejected
21. artitions through the S2000 PT is available for users within 30 seconds after touching their iButtons to the reader these iButtons being pre registered by the network controller with specific rights to control specific partitions The S2000 PT has a built in sounder which is used to indicate alarms and troubles in the system partitions assigned to this S2000 PT Sounds can be silenced either manually by pressing the SILENCE button or automatically upon elapsing the programmed operation time The module can be powered by a power supply providing 12 V or 24 V dc It is advised to use Bolid manufactured battery backed power supplies of series RIP 12 or RIP 24 The module is equipped with a tamper switch On changing tamper switch s statuses the module sends the network controller relevant messages about tampering restoring its enclosure www bolid com 6 S2000 PT General All the messages about S2000 PT events such as power failures enclosure tampering restoring turning on off the automatic mode of releasing extinguishing agent starting canceling starting agent releasing applications as well as resetting sound alarms by an operator are sent to the network controller In case of a loss of communication over the RS 485 interface such messages are collected in the non volatile memory of the S2000 PT up to 16 messages and on restoring communications they are transferred to the network controller with the time and date of origin specifi
22. ay output of an 2000 www bolid com 16 S2000 PT Operation Principles POWER Main power failed or power trouble of an 2000 COMMUNICATION No communication with an S2000 ASPT over the RS 485 bus TAMPERING The enclosure of an S2000 ASPT is open Sound Indication of Partition Statuses and User Requests The sounder of the S2000 PT operates as follows Fire Alarm Issues long beeps each two seconds Fire Prealarm Issues two beeps once per two seconds Trouble Issues a beep once per four seconds User Request an iButton is touchedto Issues a beep the reader Code the iButton has no rights Issues a long sound about 1 s for requested operation Access Granted Issues two beeps If several partitions related to the 52000 have various statuses which should be indicated the sounder indicates the status with the highest priority Fire Alarm is the status of the highest priority the Fire Prealarm is the status of lower propriety and the Trouble status is of the lowest priority Sounds can be silenced by pushing the SILENCE button When the SILENCE button is pressed the module sends the 52000 or the computer the Alarm Cancelled message Sound signaling also can be stopped automatically after elapsing a time programmed for the module see Section Module Settings No messages about automatic silencing are sent to the network controller Light Indication of the Reader If a reader is connected to the
23. button m 2 Create a new Access Group by clicking on El In the Inspector Access Group window select www bolid com 36 the proper number and type the name or a short comment optionally of the Access Group see S2000 PT Proqramminq 52000 52000 Console Programming Tool File Edit 52000 Options Language Service Pages Help Deml gt Access Groups Ac Group 1 User Number Description Partitions Partition Figure 12 3 In the Partitions window select the partitions which are enabled to be controlled for this Access Group Move them up on the created access group descriptor by left mouse button see Figure 13 52000 52000 Console Programming Tool File Edit 52000 Options Language Service Pages Help Cs Sees dum Fe s H 4 2 lt Access Groups Bi Inspector Rights gff2 ac Oroup 1 User Arming Enabled Ac Group 1 Partition 1 Sector 1 Disarming Enabled Turn Automatics On Enabled Turn Automatics Off Enabled Launch Fire Fighting Disabled Cancel Fire Fighting Disabled Partitions une sae 1 Partition Sector 1 Figure 13 37 www bolid com Orion 155 4 In the Access Groups window select the partition and give the rights to control this partition the Inspector Rights window Then you should assign the programmed Access Group with the PIN code the Access
24. dual area Network Address A unique number of the module 1 to 127 within the local RS 485 network of the Orion integrated security system Network Controller A hardware software which monitors for and controls the devices of the Orion integrated security system It can be an S2000 M console or a PC with installed Orion Pro software S2000 PT Table of Contents General au uu M ree 5 uud ge T 9 Operation Principles 13 u uuu EE o O 14 Light Indication of Module Statuses 14 Light Indication of Partition Statuses 14 FIRE LED 14 TROUBLE LED 15 LOCKED LED 15 AUTO LED 15 EXTINGUISHING LED 16 Light Indication of Alarms and Troubles in Partitions 16 Sound Indication of Partition Statuses and User Requests 17 Light Indication of the Reader 17 Agent Release 18 Events Commands Transferred to the Network Controller 21 Installatighu 23 Slandard Deler Cc 24 cuc dui T 24 S2000 P T MOUNINO ES 24 Wiring ihe RS 485 Interface Line
25. ed and maintained alarm may only reduce the risk of a burglary robbery fire or other events occurring without providing an alarm but it is not insurance or guarantee that such will not occur or that there will be no personal injury or property loss as a result CONSEQUENTLY SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING HOWEVER IF SELLER IS HELD LIABLE WHETHER DIRECTLY OR INDIRECTLY FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE REGARDLESS OF CAUSE OR ORIGIN SELLER S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER This warranty gives you specific legal rights and you may also have other rights which vary from country to country No increase or alteration written or verbal to this warranty is authorized 4 Pionerskaya Str Korolev 141070 Moscow Region Russia Phone fax 7 495 775 7155 Email info bolid ru overseas bolid com www bolid com
26. ed by the internal S2000 PT clock The module is to be programmed using the tool of configuring all the devices of the Orion system the UProg exe of version 4 0 0 825 and above All settings of the S2000 PT are stored in the module s non volatile memory The last version of the UProg exe can be downloaded from the site of the Bolid Company at the address of www bolid com in Software section The module is connected to the PC where the UProg exe is installed via the S2000M console switched to the Interface Converter or Programming mode as well as via one of the Bolid manufactured interface converters PI GR 52000 52000 USB USB RS485 The S2000 PT module is attached within premises near an operators work place at locations protected against atmospheric fallouts and mechanical damage and is designed for round the clock operation The module is not suitable for operation in corrosive or dusty environments as well as fire hazardous areas The S2000 PT module see Figure 1 has ten indicator strings 1 to 10 1 designed to indicate statuses of up to ten agent releasing applications related with the module Each indicator string of 5 two color LEDs can display such events or statuses in the related partitions as fire detectors responding S2000 ASPT troubles and locking start of the related agent releasing application as well as display the current mode of releasing automatic or manual and the current status of the extinguishing
27. elp JO Bii Partition Number 1 EEC Indicator 5 1 D D 0 0 0 0 Sound Duration Access Code Figure 6 The Work Window of the UProg for Configuring the S2000 PT You can also get an access to the module settings by loading the S2000 PT configuration from the relevant file with extension written to any data storage using the File gt Load Configuration File command or the lt F3 gt button or the EB icon Besides a new configuration file can be created by using the File gt New Configuration menu command or the lt Ctrl N gt button or the toolbar icon The command File Base Configuration is intended for loading factory setting values to the empty configuration created in the UProg 29 www bolid com O LI D Orion 155 The newly created or revised configuration can be Loaded to the module memory or Device gt Write Configuration to This Device Loaded to the memory of another Device Write Configuration to Another Device connected S2000 PT with specified network address Saved to a of the internal UProg o F2 or File Save Configuration to File format with the cnu extension Written as a text to an MS Word file me por File gt Export Configuration to MS Word MODULE SETTINGS The configuration parameters shown in Table 1 define the general operating features of the S2000 PT as well as its network parameters for opera
28. flashing and returns to steady lighting after restoring communications Light Indication of Partition Statuses Statuses of the ten Orion system partitions assigned with the module are indicated by relevant indicator strings each containing five LEDs namely FIRE TROUBLE LOCKED AUTO and EXTINGUISHING FIRE LED A FIRE LED indicates receiving responses of fire detectors connected to alarm loops of the related S2000 ASPT well as statuses of the S2000 ASPT s zones of manual and remote releasing of extinguishing agent www bolid com 14 S2000 PT Operation Principles If any zone of the related partition either a zone of alarm loops with connected fire detectors or one of the zones of manual and remote releasing has entered the Fire Alarm status then the partition is also assigned to the Fire Alarm status If there is no zone in the Fire Alarm status but at least one zone has entered the Fire Prealarm status then the partition is assigned to the Fire Prealarm status If the partition has just entered the Fire Alarm status and at another zones a Fire Prealarm message is received then FIRE LED behavior will not change On module s receiving from the network controller messages about resetting alarms on the S2000 ASPT related to the partition the FIRE LED is turned off The behavior of FIRE LEDs from the highest to the lowest priorities of partition statuses is as follows FIRE ALARM Flashes in red twice per second FIRE PREALARM Fla
29. ing with this program the console should be switched to the programming mode as described in its manual If Orion Pro software is used as the network controller program the software as described in the Orion Pro s documentation The last version of the PProg exe can be downloaded from the site of the Bolid Company at the address of www bolid com Adding the S2000 PT to the Configuration of the Network Controller 1 Run the PProg exe selecting a number of the COM port which the S2000M console is connected to in the Search window on the Devices tab and clicking the Start Searching button finishing the procedure of searching list of all connected devices will be appeared Each device in the list is shown with its address type and version number see Figure 8 After program s finding the console its configuration can be written or read Read the console configuration by the menu command 2000 Head Configuration You can also create a new configuration by the menu command File New 2 Add the S2000 PT to the tree of the devices by dragging and dropping it from the Search window to the Devices window with left mouse button see Figure 9 The Inspector Device window is designed for displaying entering and editing the parameters of a selected device 33 www bolid com Orion 155 File Edit 52000 Options Language Service 18 gt ka H a Devices 3 Inspector Devices D ue
30. module the LED of the reader indicates the following events A user has touched his or her iButton to the The reader LED flashes twice per second reader User Request The iButton toched to the reader has no rights The reader LED is off for requested operation Illegal Code The requested operation is allowed Access The reader LED lights within 30 s Granted 17 www bolid com B O L I D Orion 155 AGENT RELEASE CONTROL The S2000 PT has two control buttons for each of the ten related partitions The AUTO button switches the current mode of releasing extinguishing agent from automatic to manual and back The EXTINGUISHING button allows remote releasing or cancelling release of extinguishing agent For authorized controlby AUTO and EXTINGUISHING buttons a user shall touch his iButton key to a reader connected to the S2000 PT The key shall be enrolled by the network controller Also the key shall be assigned to a number of partitions which are enabled for this key to control as well as to specific rights to control the partitions see Section Adjusting the Network Controller for Receiving Control Commands These partitions in turns shall be assigned to the indicator strings of the 52000 PT see Section Module Settings The S2000 PT can also be assigned to a built in password an access code which enables controlling partitions without user authorization by Touch Memory devices This alternative can be used when the module is
31. nd allows user to get access to control partitions without access devices Touch Memory The S2000 PT sends this password to the network controller over the RS 485 interface when the user pushes one of the AUTO or EXTINGUISHING buttons The password access code should also be enrolled in the database of the network controller see Section Adjusting the Network Controller for Receiving Control Commands set or change an Access Code enter a four digit code into the Access Code dialog box at the bottom of the UProg window see Figure 6 Let the field empty or clear it if controlling partitions by the S2000 PT without presenting electronic keys is prohibited www bolid com 32 S2000 PT Programming NETWORK CONTROLLER SETTINGS Adjust a network controller by means of the PProg exe if it is an S2000M or by means of Database Administrator software if the Orion Pro software operates the system To program the network controller to operate the 52000 do the following gt Enroll the S2000 PT to the network controller database gt Create the relevant partitions gt Enroll all the relevant users with their authenticators PIN codes or access devices to the network controller database and assign the users to the rights to control the created partitions gt Enable the S2000 PT to control these partitions This Manual describes the procedures of programming an S2000M console by means of the PProg exe Before work
32. network controller over the RS 485 interface If a communication loss occurred during generating a message lasts more than one minute then the relevant event is stored in the non volatile memory of the S2000 PT When the communication is restored the event will be transmitted via the RS 485 interface to the network controller with the time and date assigned in accordance with the internal clock of the module The network controller synchronizes the internal clock of the S2000 PT to its own clock by automatic sending a Synchronize Clock command transferred via the RS 485 interface commonly at the beginning of each hour The S2000 PT sends the network controller over the RS 485 bus the following commands SET AUTO MODE Pushing an AUTO button when the related AUTO LED is off SET MANUAL MODE Pushing an AUTO button when the related AUTO LED is on RELEASE Pushing an EXTINGUISHING button for more than 3 s CANCEL RELEASING Quick pushing an EXTINGUISHING button The commands said above are sent only after user s granting access to control partitions see Section Agent Release Control 21 www bolid com 155 www bolid com 22 S2000 PT Installation INSTALLATION 23 www bolid com O L I D Orion 155 STANDARD DELIVERY Find the following unpacking the 2000 gt The S2000 PT Control and Indicator Module gt The data sheet gt CD disk with this User s Manual gt Four woodscrews 1 4x40
33. ommands Device 2 Loop 12 Partition 1 Fire Protection Equipment Fault Device 2 Exit 1 Partition 1 Visual Alarm 1 EXIT gt Device 2 Exit 2 Partition 1 Visual Alarm 2 KEEP OUT gt Device 2 Exit 3 Partition 1 Visual Alarm 3 AUTOMATICS OFF Device 2 Exit 4 Partition 1 Siren Device 2 Exit 5 Partition 1 Releasing Circuit Devices Monitored Zones Devices Monitored Zones A Console Status Device Address 2 S2000 ASPT Device Address 3 Type S2000 PT EJ Device Address 4 Type S2000 KPB Parameter Number Description Sector 1 Figure 11 Adjusting the Network Controller for Receiving Control Commands To adjust the S2000 PT to send control commands you must define the user rights to control the fire extinguishing system as well as module s rights to control specified partitions in the configuration of the network controller User rights are defined via assigning a user to an Access Group Each Access Group is a set of user rights which consists of a list of partitions enabled for controlling and actions permitted for each partition For an S2000 PT a user can be allowed to perform such actions as turning on and off the mode of automatic releasing extinguishing agent as well as remote starting cancelling the start of the fixed fire extinguishing installation 1 To create an Access Group go to the Access Group page of the PProg clicking the
34. ort releasing depending on its current status 19 www bolid com O LI D Orion 155 If the agent releasing application has just been started then short time pushing the EXTINGUISHING button the application will be stopped Otherwise if the agent releasing application is not started on pushing the EXTINGUISHING button for more than 3 s the related S2000 ASPT enters the modes Fire Alarm and Pre discharge Delay when the S2000 ASPT begins counting the programmed pre discharge delay and the EXIT light table is turned on Upon the expiration of the pre discharge delay the S2000 ASPT enters the Release mode In this mode the S2000 ASPT generates a starting pulse and gives a command to activate connected modules S2000 KPB The EXIT table is turned off while the KEEP OUT table is turned on Upon the expiration of the starting pulse the S2000 ASPT enters the Extinguishing mode if pressure sensors in the extinguishing agent control circuit have responded www bolid com 20 S2000 PT Operation Principles EVENTS AND COMMANDS TRANSFERRED TO THE NETWORK CONTROLLER The S2000 PT automatically sends the network controller over the RS 485 interface the following messages about its states TAMPER ALARM The module enclosure is open TAMPER RESTORED The module enclosure is closed ALARM RESET The SILENCE button is pressed on receiving an alarm DEVICE RESTART The watchdog timer is reset The S2000 PT provides buffering events sent to the
35. ow Inspection of the S2000 PT shall be performed by competent personnel of the Service Company On completing the inspection the results shall be written into an S2000 PT maintenance log book If during the warranty period the module does not meet any requirements set forth in this section this will be the grounds to raise a climb to the manufacturer The module should be inspected under the following ambient conditions Relative humidity 45 96 80 96 Ambient temperature 25 C 10 C Atmospheric pressure 630 800 mm Hg Power off the module before connecting and disconnecting wires Take into account the pre operation time of the module which shouldn t exceed 2 s www bolid com 42 S2000 PT Maintenance INSPECTING MODULE S OPERATION CONDITIONS 1 Wire the S2000 PT for inspection as shown in Figure 17 but not connecting the wires of the RS 485 bus to the S2000M console 2 Turn the module power on 3 The READY LED of the S2000 PT shall be lit steady in green for a time and then flash once per second 4 Measure the current consumed by the S2000 PT The value of the current shall not exceed 300 mA 2000 RIP 12 RIP 24 Figure 17 Wiring the S2000 PT for Functional Testing TESTING THE S2000 PT IN SELF DIAGNOSTIC MODE To start self diagnostic procedure push SILENCE button three times shortly and then once more long If the module is operable its LEDs are turned on as follows 1
36. rs operated the S2000 PT both with and without touching their Touch Memory devices Move selected partitions to the Device Rights window on the 52000 descriptor by left mouse button see Figure 16 39 www bolid com Orion 155 gt BOL D x Hv e Device Rights Inspector Device Device Rights Parameter 5 52000 console E Device amp ddress 2 Type S2000 ASPT HHH Device Address 3 Type S2000 PT _ Partition 1 Sector 1 Device Address 4 Type S2000 KPB Partitions 3 Partitions amp Partition 1 Sector 1 4 October Tuesday 13 46 56 Figure 16 Finally the changed or newly created configuration of the console can be Loaded to the console S2000 gt Write Configuration Saved in text format to a file with the E File save File gt Save As Ixt extension or encrypted to a file of gpc format www bolid com 40 S2000 PT Maintenance MAINTENANCE 41 www bolid com B O L I D Orion 155 To make sure the S2000 PT keeps proper operability it shall be inspected by a competent specialist at least on receipt and annually The inspection algorithm shall include gt Visual checking the S2000 PT for contaminations and mechanical damage gt Verifying the S2000 PT for secure mounting and wire connection conditions gt Inspecting operability of the S2000 PT in accordance with the techniques discussed bel
37. shes in red once per two seconds Norm Off TROUBLE LED The TROUBLE LED indicates such troubles and faults occurred during operating the related S2000 ASPT as alarm loop troubles troubles of S2000 ASPT executive outputs power troubles enclosure tampering and loss of communication between the S2000 ASPT and the network controller The partition is considered to be in the Trouble status is there is one of the troubles listed above in this one TROUBLE Flashes in red once per two seconds Norm Off LOCKED LED The LOCKED LED is turned on when releasing extinguishing agent for the related application cannot be started for example the door to the protected premises is open during counting the Pre discharge Delay Release is locked Lit steady in red Norm Off AUTO LED The AUTO LED shows which mode is currently set for releasing extinguishing agent at the application related with the partition automatic on responding fire detectors connected to the S2000 ASPT or manual on receiving a manual alarm from the manual call point connected to the S2000 ASPT or a remote release command from the network controller 15 www bolid com AUTO button has just been pushed The automatic mode of releasing agent is turned on The automatic mode of releasing agent is turned off EXTINGUISHING LED Orion 155 Flashes in green and red alternately twice per second until the relevant command is executed or rejected see
38. system operating So each indicator string of the module is intended to display statuses of a single S2000 ASPT device In addition each indicator string contains two control buttons 2 pushing which switches on off the automatic mode of starting fire extinguishing application as well as remotely starts cancel starting the application Seven single color LEDs 4 at the right are designed to indicate alarms and troubles retranslated by the network controller from the S2000 ASPT related to the module READY LED 3 indicates conditions of the S2000 PT itself The module has a built in sounder which indicates receiving alarms from partition related to the S2000 PT The SILENCE button 5 is designed to reset sounding manually 7 www bolid com BOLID ss E FIRE PREALARM TROUBLE ouu power COMMUNICATION Tampering A SILENCE xi 2000 ECM CONE Figure 1 www bolid com 8 S2000 PT Specifications SPECIFICATIONS 9 www bolid com v Vv Y Y 21 Control Buttons Number of Partitions Alarm and Trouble Indicators Internal Sounder Tamper Switch Event Log Capacity RS 485 Communication Port Transmission Hate Data Transmission Power Supply Input Voltage Input Power Consumed Current Alarm Mode Quiescent
39. ting as a part of an Orion ISS system Table 1 Configuration Parameters of the S2000 PT Module Parameter Description Factory Value Rm unique number of the module in the RS Network Address ABS Interface bue 1 to 127 A number of that partition in the network controller configuration which is linked Partion Number with each string of status indicators of the uoc HIREM module The time after elapsing which the module pra sounder is automatically turned off A four digit password with which the S2000 PT is registered in the network mocess controller database as a user having gus some rights to control extinguishing The Network Address parameter is intended to identify uniquely the module in the Orion device system The module sends messages and receives commands from the network controller only using the address specified by this parameter The network address must be unique for each Orion system device To program or change the network address of the module select the command Device Change Device Adaress in the menu of the UProg and enter the proper number in the range of 1 to 127 in the appeared dialog box see Figure 7 www bolid com 30 S2000 PT Programmin The network address of the 52000 can also be programmed or changed by means of the network controller as described in its Manual UPROG Address 3 S2000 PT ver 1 01 Parti
40. tion Number 1 Change the Device Address Indicator 1 Enter the new address 3 Indicator 2 Indicator 3 i DK 0 0 fresa fo EZ EZ EZ EZ EZ Jo Sound Duration Access Code Figure 7 In order the indicator strings 1 to 10 displays statuses of actual partitions of the Orion system programmed in the network controller database these indicator strings should be linked to the partitions by the set of Partition Number parameters set or change Partition Number left clock the field of the programmed indicator string and enter the partition number into the relevant dialog box in the upper part of the UProg window see Figure 6 For unused indicator strings set the partition Number to zero 31 www bolid com O L I D Orion 155 The Sound Duration parameter defines the time of module sounder s being turned on when an alarm is received To set or change the Sound Duration enter a proper value ranged from 0 to 255 to the 55 relevant dialog box at the bottom of the UProg window see Figure 6 0 if sound signaling of the module is to be disabled 1 254 the time in seconds since module s receiving an alarm until the sounding is turned off automatically 255 to disable automatic silencing sounder will be on until the SILENCE button is pressed The Access Code parameter defines a built in password PIN code of the module a
41. tuses of related partitions related S2000 ASPT gt Light and optionally sound indication of various alarms and troubles in related partitions gt Remote releasing extinguishing agent and remote cancellation of releasing extinguishing agent for related applications gt Enabling and disabling the automatic mode of releasing extinguishing agent for related applications Remote control of fire extinguishing processes by the S2000 PT is performed through the network controller The network controller can be either an S2000M fire and alarm console of versions 2 03 or a PC with Orion Pro software installed The 52000 receives an information about statuses of related partitions related S2000 ASPT from the network controller over the RS 485 interface representing this information by means of light and sound indication In addition if programmed the S2000 PT transfers the network controller user commands to turn on off automatic mode of releasing extinguishing agent and to start cancel starting releasing The network controller upon receiving such a command analyses the received data makes a decision about gaining access to the requested operation and if access is granted retranslates the executive command to the relevant S2000 ASPT To establish authorized remote control of releasing extinguishing agent a reader of iButtons Touch Memory access devices can be connected to the 2000 In such case controlling system p