INSTALLATION & USER MANUAL
Contents
1. Press MODE to return to the home screen OR to continue on to check the status of the batteries and charge current e After any change to the TC settings the TC function will be enabled and AUTO will be displayed Enable Disable the TC Function I Press and hold the AUTO button for 2 seconds until the screen changes The screen will read either AUTO TC AUTO P1 or be blank which disables both automatic functions Each time you press and hold the AUTO button for 2 seconds it will scroll the screen to the next option When the correct Auto Function is displayed you are done Since 1935 13 AN Wasco Skylights INSTALLATION amp USER MANUAL CHECKING STATUS OF BATTERIES AND CHARGING CURRENT 11 Press any key to wake up the remote if the LCD display has powered off Press MODE Press ZONE as necessary to choose the appropriate zone 1 thru 9 Press ENTER to save your selection MAX OPEN will be displayed and flashing Press A Y until is displayed and flashing Press ENTER Press A Y to choose the ID number 1 thru 9 of the operator within the zone Press ENTER to save your selection Press A Y to cycle viewing either the solar charging rate in mA operator battery status or the remote battery e Solar charging rate is measured in Milliampere mA Refer below for more information on charging rate Press MODE to return to main screen Charging Ra
2. button for 2 seconds until the screen changes The screen will read either AUTO TC AUTO P1 or be blank which disables both automatic functions Each time you press and hold the button for 2 seconds it will scroll the screen to the next option When the correct Auto Function is displayed you are done When the Auto function is enabled it will stay enabled until it is turned off Since 1935 INSTALLATION amp USER MANUAL SETTING MAX OPEN LIMIT n e eS at ee sk ee Oo a 12 The travel distance that the operator s will open a window skylight MAX OPEN can be reduced for all operators within a zone and each zone may have a unique MAX OPEN value This may be beneficial to prevent rain or excess wind from entering when the operator s is open The factory setting MAX OPEN limit is set to open up to 80 of full open position Press any key to wake up the remote if the LCD display has powered off Press MODE Press ZONE as necessary to choose the appropriate zone 1 thru 9 Press ENTER to save your selection MAX OPEN will be displayed and flashing Press ENTER Press A Y to set the percentage in increments of 10 Press ENTER to save your setting TC is now displayed Press MODE to return to the home screen OR to continue on to set the Temperature Control TC ZONE Since 1935 INSTALLATION amp USER MANUAL SETTING TEMPERATURE C
3. is critically low the operator will be allowed to close however will not be able to open until the battery is recharged to a sufficient level _ 8 SET aE S Remote Battery Status _ Jj SET se m in U gt A Solar Charging Rate E3 _ 8 SET R f Operator Battery Status Since 1935 INSTALLATION amp USER MANUAL RE ZONING 15 e 10 l1 12 13 Recommended only for when multiple operators are used with a single remote This process removes the operator from the assigned zone and or ID number but remains paired to the remote The operator then is reassigned to a new zone and or ID number on the same remote CAUTION If this is not done correctly you will have to re pair the Remote to the Operator which would involve unplugging the Operator s battery Please read these instructions carefully first before performing this operation Press any key to wake up the remote if the display has powered off Press and hold release when PAIR is displayed Press again to display RE ZONE Press as necessary to choose the appropriate zone 1 thru 9 of the operator to be moved to another zone Press to save your selection Press A Md to choose the ID number 1 thru 9 within the zone in which the operator is assigned to Press ENTER to save your selection SUCC will be displayed The operator will now be unassigned from the previous zone and ID
4. the remote used 3 Temperature control TC may also have to be set to have a lower MAX OPEN value than the otherwise set MAX OPEN 4 Temperature change must be maintained for 10 minutes before the temperature control TC function will operate For more Trouble Shooting Tips please visit www SolarSmartOpener com ADVANCED SERVICE OPERATIONS RESET OF REMOTE TO FACTORY SETTINGS 1 Press any key to wake up the remote if the display has powered off Press and hold MODE release when PAIR is displayed 2 3 Press again to display RE ZONE 4 Press to display M in the upper right corner as flashing 5 Press FAIL is displayed as flashing 6 Press and hold release when rF TEST is displayed Press MODE repeatedly until rET FAC is displayed 8 Press ENTER all the screen display segments will be visible while the remote runs a self test which lasts for a few seconds After which will be displayed The remote has now been reset to factory settings it is no longer paired to any operators Since 1935 INSTALLATION amp USER MANUAL Please record your Remote settings for ease of reference as well as assist in troubleshooting Pee eee eee ennenen neb nene nee nenen Renne nen Renne Renne nee nen nenen Renee nenen een ee eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeneee eee eee ee ee eee eee neers T TTT TTT IHH TT TEE 6 6 I E HE d I Ud ene ss e 4 7 7 LU di HU Uu 4 ddid uddudd 4 8 8 T Lanea 1 dd Uid uuig 4
5. tilt to prevent water from pooling The sensor location depends on many factors The key to proper installation is that the sensor must be level and exposed when the operator opens the unit The wires from the sensor to the operator must be ran to the operator in a water proof manner so as to not induce water penetration that could damage the interior The sensor is not polarity sensitive so it does not matter which wire goes to which connector in the operator By default the rain sensor is enabled when the remote is initially paired to the operator regardless of whether the rain sensor is attached or not When the rain sensor is enabled a small va umbrella will be displayed in the top right hand display box 10 e n O m OM US CU i d _ Press ENTER to save your setting LCD displays steady ON or OFF for one second then SUCC for 2 seconds indicating To enable or disable the rain sensor press any key to wake up the remote if the LCD ZONE display has powered off Press MODE Press ZONE as necessary to choose the desired zone After the desired zone is flashing press ENTER MAX OPEN will know be flashing Press A M until the T icon is displayed and flashing press ENTER Press A Y to choose the ID number 1 thru 9 within the zone Press ENTER to confirm your selection Press A Y to choose between ON and OFF while they are flashing success Press MODE a few
6. 9 9 ddu dd HU E OOOO Lo ene ma I ss ss ss s ss ss l 1 dd id HU 4 2 dd id HU Uu 4 dd Udd i ndd ddd 1 5 5 dd dd leanne aaa nia si clirio iin lii A 4 6 i T E 1 7 T SEE EEE EEE EEE a a a 1 8 T aa 1 9 Since 1935 17 AN Wasco Skylights
7. INSTALLATION amp USER MANUAL hey MODELS EVMS amp GSVMS SOLAR SMART SOLAR SMART with Rain Sensor Since 1935 O 800 388 0293 Fax 207 216 4562 cs wascoproducts com www wascoskylights com Wa Eastern Facility 85 Soencer Drive Unit A Wells ME04090 Western Facility 6645 Echo Avenue Reno NV 89506 SKYLIGH O INSTALLATION amp USER MANUAL TABLE OF CONTENTS Features In The Box Basic Operation 2 3 4 5 Solar Panel and Rain Sensor Installation 6 Remote Setup and Configuration 7 Pairing Remote to Operator 8 Multiple Remotes 8 Secondary Remote Configuration 10 Rain Sensor Operation 11 Time to Close Operation 12 Setting MAX OPEN Limit 13 Setting Temperature Control TC 14 Checking STATUS of Batteries and Charging Current 15 Re Zoning 16 Remote Display 17 Troubleshooting Tips FEATURES Operator Highlights 1 Powered by a solar charged NiMH battery pack 2 End user replaceable battery pack 3 Operating force rating of 60 lbs at the chain 4 Maximum opener chain travel of 8 inches with option to program various lengths 5 Bright White cover standard Paintable surface for custom color match 6 Attachment link on chain is fastened to the sash by a release pin 7 AC trickle charger included 8 Adaptable to awning and hopper windows and skylights Remote Highlights 1 Large and readable display with bi directional feedback from the operator a Open Close status pe
8. NOTE The remote has been configured and paired by Wasco Keep instructions for future use e The following are applicable for configuring the main remote only To configure additional remotes refer to Multiple Remotes for more information e Pressing MODE does not work when zone in remote display is set to ALL Press ZONE to exit zone ALL e All steps must be performed within 30 seconds or the remote control will default to the previous settings 1 Open the remote battery cover and install the two AA alkaline batteries and replace the cover 2 All the screen display segments will be visible while the remote runs a self test which lasts for a few seconds After which will be displayed 3 Press A to choose either C Celsius or F Fahrenheit 4 Press to save your selection 5 Press A Y to choose either M main or S secondary Select M for main Note Secondary is only used when using additional remotes Refer to Multiple Remotes for more information 6 Press ENTER to save your selection 7 ZONE ALL and the temperature should now be displayed Since 1935 INSTALLATION amp USER MANUAL PAIRING the REMOTE to the OPERATOR e Pairing sets up communication between the remote and the operator e The remote will be able to control all operators assigned within a single zone simultaneously or control all zones at once e There are 9 zones 1 thru 9 with each zone containing 9 ID nu
9. ONTROL TC e Automated temperature control TC can be set for all operators within a zone and each ZONE zone may have a unique TC value e When set and the remote is set to AUTO the temperature control will open the operator s within a zone when the temperature setting is reached e It will close the operator s when the temperature drops greater than 5 degrees F or 2 degrees C below the set level e This automatic function is based on the temperature at the remotes location and must be maintained for approximately 5 minutes 1 Press any key to wake up the remote if the LCD display has powered off Press MODE Press ZONE as necessary to choose the appropriate zone 1 thru 9 Press ENTER to save your selection MAX OPEN will be displayed and flashing Press A Y until TC is displayed and flashing Press ENTER Press A Md to set the desired temperature or NULL to turn function off for this zone 9 Press ENTER to save your selection SS SS Oe Le OP e The temperature in which the operator will run has now been set Next a MAX OPEN limit is set specifically for when the TC function opens the operator This MAX OPEN cannot exceed the limit set for basic operation 10 Press A Y to set the percentage in increments of 10 of the temperature controlled MAX OPEN Operator s will not open past MAX OPEN set above Press ENTER to save your setting 11 P1 is now displayed 12
10. l two AA alkaline batteries and replace the cover 2 All the screen display segments will be visible while the remote runs a self test which lasts for a few seconds After which will be shown on the Display to indicate input is reguired Press A Y to choose either C Celsius or F Fahrenheit Press ENTER to save your selection Press A Y to choose either M main or S secondary Select S for secondary Press ENTER to save your selection ZONE ALL and the temperature should now be displayed FM a a P Since 1935 INSTALLATION amp USER MANUAL 1 SECONDARY REMOTE STEPS a Press and hold MODE release when PAIR is displayed and the S in the upper right corner is flashing b Press ENTER The secondary remote will now be waiting to receive the transmission from the main remote It will wait for 30 seconds 2 MAIN REMOTE STEPS a Press and hold release when PAIR is displayed b Press twice to move past RE ZONE to display M in the upper right corner as flashing c Press to begin transmitting the settings to the secondary remote d SUCC will be displayed on a successful transfer of settings i _ If a FAIL message is displayed instead be sure that the secondary remote is still configured to be waiting to receive the transmission Press ENTER to retry Since 1935 INSTALLATION amp USER MANUAL RAIN SENSOR The rain sensor should be installed horizontally with a slight
11. mbers 1 thru 9 Each operator will need to be assigned to a zone and ID number Each zone and ID number combination can only be assigned one operator e The following instructions are applicable to pairing the first and additional operators to a single remote e Each operator can only be paired with one main remote however multiple secondary remotes may be used once setup and configured The Operator NOTE The Solar Panel must also be The remote will need to be paired within 2 minutes or the operator will default back to the previous settings Remove the battery cover from the operator If connected disconnect the battery connector from the operator circuit board for at least 30 seconds disconnected at this time Connect the battery connector to the operator circuit board pressing firmly until the plug is locked into place The red light on the circuit board will continually blink while it is in pairing mode The Remote gt aE SS Press any key to wake up the remote if the display has powered off Press and hold the MODE release when PAIR is displayed Press ZONE as necessary to choose the appropriate zone 1 thru 9 Press ENTER to save your selection Press A Y to choose the ID number 1 thru 9 within the zone ID numbers already in use will not be displayed Press ENTER to save your selection The remote will attempt to pair to the operator continues on ne
12. number DO NOT STOP HERE steps 8 9 and 10 must be completed a Press ENTER to retry if a FAIL message is displayed instead Press ZONE to choose the new zone 1 thru 9 the operator shall be assigned to Press ENTER to save your selection Press a Md to choose the ID number 1 thru 9 within the zone in which the operator shall be reassigned to Press ENTER to save your selection SUCC will be displayed The Operator will run through an entire open and close cycle Since 1935 INSTALLATION amp USER MANUAL REMOTE DISPLAY Remote Battery Indicator Rain Sensor Indicator Solid Enabled Blinking Rain Detected Operator Battery Indicator M main S secondary Remote Maximum Opening Limit Zone ID Re Zoning Indicator Function ON OFF Indicator Temperature Control Program 1 Time to Close Settings Mode Indicator Solar Charging Indicators Pairing Mode Indicator Status Indicator Numerical Display TROUBLESHOOTING TIPS 1 Ifin AUTO mode and operator s is not working as expected make sure none of the secondary remotes are set to AUTO mode and that temperature control TC for all zones on secondary remotes are set to NULL 2 MAX OPEN can be set to different values on both the main and secondary remotes The operator will open to the MAX OPEN setting of the remote used to open it If the operator is not opening the proper amount be sure to check that MAX OPEN is set properly on
13. operly except when the Rain Sensor is enabled cleaning the Rain Sensor is recommended Since 1935 INSTALLATION amp USER MANUAL TIME TO CLOSE 11 The Time to Close P1 function will automatically close the operator after a user defined time period The user selected time period is in 10 minute increments from 0 to 1 hour From 1 to 24 hours the increments change to 30 minutes oc NOD E WON 10 11 Press any key to wake up remote if the LCD display has powered off Press MODE the LCD should display SET and ZONE should be flashing Press ZONE as necessary to choose the appropriate zone 1 9 When the correct zone is flashing press ENTER MAX OPEN will be displayed and flashing Press A Y until P1 is displayed and flashing Press ENTER Press A W until the desired Time To Close is displayed and flashing or NULL to turn function off Press ST is now displayed and flashing Press to return to the home screen OR press A Y to scroll and set other features The Time To Close selection will be retained in memory until changed by the user However you must activate the AUTO feature for either the Time To Close or the Temperature Control TC function for it to operate NOTE The Time To Close and Temperature Control cannot be enabled simultaneously for the same zone Enable Disable the TIME TO CLOSE Function To activate the AUTO function you must start in the Home screen Press and hold the
14. rcentage displayed b Operator and remote battery level percentage displayed c Solar charge rate displayed in mA d Temperature display 2 9 programmable zones with up to 9 operators assigned per zone Able to control up to 81 operators 3 Automatic temperature control function 4 Multiple remotes can be used on a Main Secondary relationship Pairing and settings can be sent from a main remote to secondary remotes wirelessly 5 Stand up base with wall mount option 6 Remote uses standard 2 AA batteries Since 1935 INSTALLATION amp USER MANUAL IN THE BOX Solar Smart Operator SOLAR SMART REMOTE operator battery cover operator battery chain clip with release pin small flat head screw driver remote remote battery cover 2 AA batteries wall mount attachment AA Batteries included Wall Mount solar panel with wiring pigtail rain sensor with wiring and bracket AC trickle charger stainless steel mounting bracket 2 stainless steel bracket tabs 4 stainless steel bolts Remote Battery Cover 4 stainless steel nuts ST Chain Clip Battery Cover Operator Battery W 7 4 AV UA Connector MA SOLAR PANEL Bracket Tabs SOLAR SMART OPERATOR Since 1935 INSTALLATION amp USER MANUAL BASIC OPERATION SOLAR SMART REMOTE LCD Display Selection Button Menu Button Selection Button OPEN UP Buttons Function Button CLOSE DOWN B
15. te mA is the abbreviation for Milliampere which is a unit of electrical current flow In this case it is the measurement of current into the battery when charging and it will range between 0 and 150 mA The charging measurement is taken each time the status is reguested and is a snap shot of the conditions at that particular moment in time This measurement is highly variable and depends directly upon the level of sunlight on the solar panel Be aware of external influences which affect the light level these are direction and angle of exposure of the solar panel to the light source sky conditions clouds man made structures or trees which cause shadows on all or part of the solar panel and maintenance of the solar panel itself to keep it clean Current flow is also highly dependent upon the battery state of charge and the status measurement may report zero or low mA even when solar and all other conditions are optimum For example the solar panel could be outputting 40 mA on a battery that has a low charge however on a battery with near full charge the output may only be 10 mA Solar Smart limits the maximum charge current for safety reasons to extend battery life and to prevent over charging damage to the battery Battery Alerts 14 The R icon will be displayed on the remote when the remote batteries are in need of replacement The icon will be displayed when the operator battery is low When the operator battery
16. times to return to the home screen a If setting not successful LCD displays FAIL for 1 second then returns to the same step 8 to retry setting RAIN SENSOR OPERATION When a drop of water is on the sensor the operator may not react immediately The control system actually takes multiple reading in an effort to avoid false readings and possible cycling of the operator before it sends the close or open commands If the operator is manually opened when the rain sensor is enabled AND there is water present on the sensor the operator will close and the umbrella icon will blink on the Remote If you desire to open the operator at this time the sensor will need to be disabled before it will stay in the open position If the Rain Sensor and the Automated Temperature Control are enabled at the same time the Rain Sensor will take precedence over the Temperature Control In other words if rain is detected the operator will close regardless of the temperature until such time as water is no longer detected on the sensor before it will automatically re open As noted above the rain sensor is designed to detect a lowering of the resistance between the metallic strips on the sensor The resistance can be lowered by a number of factors including moss sap heavy dew or condensation drops from surrounding structures Therefore it is important to periodically clean the sensor to maintain proper operation If all operations function pr
17. uttons e Using the operator requires that it has been paired to the remote Refer to Initial Remote Setup and Configuration Opening and Closing of an Operator 1 Press any key to wake up the remote if the LCD display has powered off Press ZONE to choose a single zone 1 thru 9 of operators or ALL to operate all operators in all zones 2 3 Press OPEN or CLOSE to open or close the window skylight 4 Press OPEN or CLOSE during operation to STOP the operator at any time Enable Disable Automatic Functions 1 Press and hold AUTO to show or remove AUTO from the display thus enabling or disabling the temperature control TC or Time to Close P1 functions Since 1935 INSTALLATION amp USER MANUAL INSTALLATION of the SOLAR PANEL NOTE The skylight needs to be installed on the roof before attaching the solar panel l Review the separate instructions for motor operation and open the skylight fully with the remote control 2 Connect the solar panel to the wire on the exterior of the skylight at the low side The connector can only go together one way and will click when locked together 3 Locate the solar panel on the skylight frame as shown below centered side to side Install the panel with the screws supplied 4 Close the skylight to complete the installation E Since 1935 INSTALLATION amp USER MANUAL INITIAL REMOTE SETUP and CONFIGURATION
18. xt page Since 1935 INSTALLATION amp USER MANUAL 7 SUCC will be displayed to indicate a successful pairing The operator will then fully open then close one cycle DO NOT press any buttons on the remote until this cycle completes a Ifa FAIL message is displayed press ENTER on the remote to try to pair again b If a FAIL message is displayed again ensure that the operator is in pairing mode If the red light is not still blinking disconnect and reconnect the battery connector on the operator and repeat steps 1 7 again MULTIPLE REMOTES e t is intended that one or multiple operators may be controlled from multiple secondary remotes This is done by sending the pairing and settings stored in the first configured M main remote to the additional S secondary remote s Secondary remotes will be copies of the main e Any changes to operator zones ID numbers and or adding additional operators can only be performed using the main remote The changed settings would then need to be re sent from the main to the secondary remote s e Ensure that a main remote has been configured as outlined in Remote Setup and Configuration and that it has been paired to the operator s as described in Paring Remote to Operator Secondary Remote Configuration e All steps must be performed within 30 seconds or the remote control will default to the previous settings 1 Open the remote battery cover remove and reinstal