1. Connection TCP socket inactive timeout minutes Packet mode of serial input Device ID Report device ID when connected Setup password 192 168 0 10 255 255 0 0 0 0 0 0 Auto Disable 80 0 0 0 0 Auto 10 Disable al Disable
2. San Telequip P Ltd 4 Crystal House 235 Navi Peth Off LBS Road Pune 411 030 India o SAN TELEQUIP Phone 91 20 24320023 24334423 65001587 Connecting Converting Leading email info santelequip com Document Name User Manual for SCIOTK Serial to Ethernet Converter Index Technical Specifications ee a vas ee 1 Installation Procedure 1 LED Indications 2 Configuration Procedure Configuration through Utility see a ves one 2 Configuration through HTTP ine ve see 3 Default setting a ve PA ne 5 SC10TK is Serial to Ethernet Converter It is an Interface Converter between Ethernet and TTL Signals TECHNICAL SPECIFICATIONS ___ Communication Interfaces Mechanical Connectors Pp Dimensions Pp Power Supply S Po Environmental Relative Humidity 10 to 90 RH non condensing Table 1 INSTALLATION PROCEDURE Power ON the device The SYS LED Red will glow and flash Insert RJ45 jack into the RJ45 socket of the converter The LAN LED green will glow When you finish these procedures and LED displays are as shown the hardware is properly installed and On line You can use the Setup Tool SC1OTK Config exe to setup the IP Address Subnet Mask and MAC Address For the advance setup please use the IE or other Browsers Refer to the section below for details Uuuu CONNECTORS amp PIN DETAILS J4 4 Pin Relimate Pin 1 TX Pin 2 RX Pin 3 RTS Pin 4 CTS J5 2 Pin Re
3. ata when done it will show the confirming message Remark Always run the View Refresh after any changes for confirmation San Telequip P Ltd 4 Crystal House 235 Navi Peth Off LBS Road Pune 411 030 India 0 SAN TELEQUIP Phone 91 20 24320023 24334423 65001587 Connecting Converting Leading email info santelequip com CONFIGURATION THROUGH HTTP IE OR OTHER BROWSERS In addition of IP address and Subnet mask specific device settings can be set through HTTP protocol No special software will be required By pressing Alt Enter or select Device Settings in the Config menu will open a new window in browser to login into the device Alternatively if IP address of the converter is already known you can connect to the converter directly by providing IP address in the URL field of browser EN Exploring Login Eile Edit View Go Favorites Tools Help e gt 0 E a Back owad Stop Refresh Home Search Favorites History Channels Fullscreen Mail Prin Edit Address E http 61 222 2 30 Controller Status System time elapsed 01 17 06 Firmware release date Sep 42001 03 42 Ethernet address 00482B2E0F06 Setup Login Password i stat 6 7D E Exploring Login E34 1 02PM gt Activated IE gt Key in the IP address of the SC1OTK hardware that is going to setup frame and press Enter gt The first Login frame will show up You do not have to key in an
4. email info santelequip com ag SAN TELEQUIP Connecting Converting Leading 13 Report device ID when connected Enable disable In TCP mode if this parameter is enabled every time when the socket is connected converter will immediately report device ID in the following formats i Serial 1 nnnnnA LF CR ii Serial 2nnnnnB LF CR ii Digital I O nnnnnC LF CR Total 8 bytes length where nnnnn is 5 digit device ID assigned by the user Attention If the SC1OTK Gateway address is not same as the computer that is doing the setup then the Login frame will not appear unless the SCIOTK Gateway address is setup same as the computer When finished please press Update The File Edit View Go Favorites Tools Help fa Gl amp Back Forvard Stop Refresh Home Search Favorites History Channels Fullscreen Controller updated Now restarting frame will show Figure 9 Address http 61 222 2 30 Update htm Controller updated Now restarting When the frame is back to the Login frame which means the advance setup it done you can close the browser Astar K A if Me untitled Paint HyperTerminal B New Connecti BwinSock Hy 3y Exploring jro ie 1 50 PM SC10 EK Default Parameters List e IP address Subnet mask Gateway address Network link speed DHCP client Socket port of HTTP setup Destination IP address socket Port TCP client and UDP
5. erated program San Telequip P Ltd 4 Crystal House 235 Navi Peth Off LBS Road Pune 411 030 India Phone 91 20 24320023 24334423 65001587 email info santelequip com ag SAN TELEQUIP Connecting Converting Leading Advance setup frame Parameters Fig 7 amp 8 below 1 IP address If DHCP client mode is enabled and there is a DHCP Server on the network this field will be assigned by DHCP server automatically otherwise enter manually 2 Subnet mask If DHCP client mode is enabled and there is a DHCP Server on the network this field will be assigned by DHCP server automatically otherwise enter manually 3 Gateway address Gateway is a device which connects local network to external network Please type it correctly If there is no Gateway on the network just leave as 0 0 0 0 If DHCP client mode enabled and there is a DHCP Server on the network this field will be assigned by DHCP server automatically 4 Network Link speed Select between 10 100 Auto 5 DHCP client DHCP client mode could be enabled disabled If DHCP enabled there should be a DHCP Server on the network If DHCP disabled IP address Subnet mask and Gateway address should be manually assigned etup MICTOSO nternet Explorer wj AN File Edt View Favorites Tools Help ay Q Back x a A pi Search He Favorites 4 2 A Address http 192 168 106 24 5etup htm i M Eo Lins Controller Setup S
6. limate for Power Terminals as marked on the PCB San Telequip P Ltd 4 Crystal House 235 Navi Peth Off LBS Road Pune 411 030 India B SAN TELEQUIP Phone 91 20 24320023 24334423 65001587 Connecting Converting Leading email info santelequip com LED INDICATIONS SYS CPU health Flashes once a second LAN When On line the LED will remain on 10 100 Mbps ON when 100 Mbps CONFIGURATION OF SC10TK USING TOOL SC10TK CONFIG EXE Ethernet Manager ml fc Ethernet Manager view Config view Config IP Address Subnet Mask MAC Address Device ID Refresh FS Subnet Mask MAC Address Device ID TORT TM el LOL 8 81 3C D8 DS 38 Exit Alt F4 255 255 0 0 6 01 3C D6 D5 38 Devices detected 1 Devices detected 1 SC1OTK Config Setup Tool is used to detect and setup the SC1OTK on the Network When you activate the tool it will detect the installed SC1OTK as shown in the Figure 1 The SC1OTK CONFIG Setup Tool can setup only one SCIOTK at a time Please shut down or off line other SC1OTK converters The Default IP address is 192 168 0 10 View Refresh Figure 2 View Exit Figure 2 Note Configuration happens only when the device password is empty SC10TK CONFIG EXE SETUP TOOL FUNCTIONS IP Address setup Subnet Mask setup Set IP Address IP Address 192 168 0 10 Subnet Mask 255 255 0 0 Cancel Similarly Config MAC Address setup when done it will show the confirming message Config Reset D
7. ubnet mask Gateway address Socket port of HTTP setup Socket port of serial FO Socket port of digital VO Destination IP address socket port B TCP client and UDP Connection Auto Y TCP socket inactive timeout minutes Be ee baud rate parity data Interface of serial IO Packet mode of serial input Report device ID when connected C Update Done l Internet Figure 7 6 Socket port of HTTP 80 7 Destination IP Address socket port Server s IP address amp Socket port no 8 TCP socket inactive timeout To identify whether the socket is active or dead If there is no any data transferred within the defined timeout period 1 to 99 minutes then it probably a dead socket and the socket will be closed automatically A new connection can be accepted again The timeout period can be set by users to fit different kinds of application 9 Serial I O settings Serial Com port Baud rate Parity Data bits Stop bits 10 Interface of serial I O Select RS232 or RS485 RS422 11 Packet mode of Serial input Enabled Disabled If packet mode is enabled the data from UART will be deferred until the input buffer is full or the converter detects a 10 character packet gap and no more characters arrive 12 Device ID User assigned ID number for the converter Available ID is 0 65535 San Telequip P Ltd 4 Crystal House 235 Navi Peth Off LBS Road Pune 411 030 India Phone 91 20 24320023 24334423 65001587
8. y Password just press Login gt If you cannot login it means you have to key in the password gt If you do not know the password you can run the SC1OTK CONFIG exe Reset to reset the setup Note If the domain of the converter is different from the computer running the browser the login page won t appear unless the converter s Gateway Address has been correctly set Login Screen Parameters fig 5 above System time elapsed The time elapsed since start of this device Day Hour Minute Second format This information can be useful in identifying reliability of system yV Firmware release date V Ethernet address Unique MAC Media Access Control address y Password Factory default is empty However it is not recommended to leave empty in field operation If you cannot login it means you have to key the password If you do not know the password you can turn Off the power and then use any point tip to press Reset button and hold it and turn on the power The password will be reset to the factory default as empty The converter uses the same password protection mechanism commonly used in Windows NT or UNIX If there are more than 3 consecutive failures in password check during login the login function will be disabled for 15 minutes During this 15 minutes period even if you supply a correct password login will not proceed This prevents intruder from finding the password by computer gen