Home

User Manual

image

Contents

1. Open the door excessively The ground is no neat The knob of temperature controller placed soon freezing area or freezing area lower position Decrease the times of opening Improve the position of placed Adjust the knob to the place higher than soon freezing area or freezing area INSTALLATION 1 Never have unit higher a 45 degree angel while transporting when installing unit must be leveled 2 Please be careful while moving and installing unit so that the compressor and system do not get disrupted OPERATION AND CAUTION When you plug the unit there will be a green light if you do not see a green light please do step 1 of troubleshooting If this does not work please call for service CAUTION 1 Never operate the machine with Soon freezing area for a long time less than 24 hrs Otherwise it will not allow the compressor to shut down and shorten the compressor s life 2 The knob of temperature controller can not turn from Soon freezing area to Refrigeration area directly It only can be turn clockwise from Refrigeration area to Soon freezing area DEFROSTING i When the thickness of frost attain 5mm it should divided the frost on time Otherwise affect to make the result of cold 2 Before six hours of defrosting Please make the knob of temperature controller placed the Soon freezing area place to guarantee the lowest temperature w
2. Murbc TOR PUUN G TURER Turbo Air Speeds up the Pace of Innovation Chest Freezers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment TSD 27CF TSD 35CF TSD 47CF TSD 60CF www turboairinc com CONTENTS SPEGIFIGATIONS eaten eee 2 PRODUCT CHARACTER 2 TROUBLESHOOTING Doo ie oi ea tea 3 INSTALLAT IGN oil ec pna 4 OPERATION AND GAUTION apei ee 4 DEFROSTIN 5 CLEANING amp MAINTENANCE niesen 5 CAUTION setten S epoca dot K edet 6 PARI IDEN IFICATIOIN more ere ini anna non n ia aa 7 ELECTRICITY PRINGIPLE DIAGRAM 8 WARRANTY ot ee ea dace i op i di ela 9 10 Model Basket CU FT HP V Hz Amps Refrigerant Weight TSD 27CF 2 4 9 1 5 115V 60HzZ 2 0A 1 4 107 Ibs TSD 35CF 2 7 3 1 4 115V 60Hz 2 5A R134A 125lbs TSD 47CF 3 10 5 1 3 115V 60Hz 3 5A R134A 155 Ibs TSD 60CF 3 11 2 1 3 115V 60Hz 3 5A R134A 160 Ibs PRODUCT CHARACTER This product which combines the essence of European and Asian product design adopts many advanced technological features It has the advantage of beautiful shape quick chilling and energy saving It is outstanding for sales as well as strong a variety of frozen foods Rational insulation layer outstanding energy saving Enlarge 30 congealed area from adopting bottom condenser
3. Adopt inner evaporator with aluminum plank tub inside wall is neat and clean Heavy duty flat inner tank white PVC coated baskets included Design for convenient access attractive curved glass lids Unique folding door and additional inner push door to show fine insulation effects Heat Reflective Glass to save energy DAW BR Q 2 5 caster More convenient to move TROUBLESHOOTING The following phenomenon is normal which won t impact the freezer s natural running 1 When freezer is running the sound of the flowing water may be heard from the internal system of refrigerant This is normal 2 When freezer is running the compressor can feel hot to touch This is normal 3 The frost will appear on the surface of the freezer when there is a high degree of environmental humidity and the frost can be wiped down Troubleshooting Familiar breakdown and handle way SYMPTOMS 2 Disable to cooling 3 The noise is big Can t shut down of machine CAUSES Power off Unplug The set temperature is too higher The knob of temperature controller placed higher position for example 2 or 3 Put the freezer in the sunshine or close the hot object Excessive food stored at one time more than 20 of the storage volume SOLUTIONS Checking by electricity Check Turn the knob to the higher position for example 4 or 5 Change the place Less than 20 of the storage volume
4. N CORDS LOW VOLTAGE OR VOLTAGE DROPS TO THE UNIT NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESSED IMPLIED OR STATUTORY EXCEPT THE ONE 1 YEAR PARTS amp LABOR WARRANTY AND THE ADDITIONAL FOUR 4 YEAR COMPRESSOR WARRANTY AS DESCRIBED ABOVE THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES INCLUDING IMPLIED WARRANTY AND MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF Outside U S and Canada This warranty does not apply to and Turbo Air is not responsible for any warranty claims made on products sold or used outside the continent of the United States and Canada
5. THER WARRANTIES INCLUDING IMPLIED WARRANTY AND MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF 5 TRANSPORTATION COSTS Turbo Air will accept parts covered under this warranty freight collect provided that shipment has received prior approval Turbo Air is not responsible for any other transporation costs but will ship freight collect pars either repaired or replaced under these warranties 6 WARRANTY CLAIMS All claims should include model number of the cooler the serial number of the cabinet proof of purchase date of installation and all pertinent information supporting the existence of the alleged defect Any action or breach of these warranty provisions must be commenced within one 1 year after that cause of action has accrued Abc TOR MANUFAC TURER 4184 E Conant St Long Beach CA 90808 TEL 310 900 1000 FAX 310 900 1077 TOLL FREE 1 800 627 0032 U S A amp Canada Website www turboairinc com Warranty Claims All claims for parts or labor must be made directly thorough Turbo Air All claims should include model number of the unit the serial number of the cabinet proof of purchase date of installation and all pertinent information supporting the alleged defect In case of compressor replacement under warranty either compressor or compressor tag must be returned to Turbo Air along with above listed information Failure t
6. hen take out the frozen food 3 Cut off the power and take out the food then divided the frost Please can t spare away with sharp weapon in order to prevent the damage of the inner wall After defrosting wipe to freezer with cloth and connect the power supply CLEANING AND MAINTENANCE 1 2 Before cleaning you must turn off the power Wipe the inside and outward appearance of freezer by cotton cloth Then dry with dry cloth Please can t use the organism melting agent washing power hot water and harmful material to sweeping Please clean the dust of compressor and condenser every 3 months to keep the good result of cold Do not place heavy objects on the top of freezer CAUTION 1 The freezer should be provided the fit fuse Never share one electrical outlet with other electrical appliances Otherwise it will not have correct power supply and may start fire 2 Make sure the freezer use its own dependable ground cable to avoid accidents 3 In the using process freezer should be installed with safe and dependable voltage stabilizer Make sure the power is not smaller than 1000W Otherwise the compressor will burn down 4 Once the power has been off or shut down please wait for at least five minutes and then restart 5 Damaged power wires and plug should be replaced immediately by professional personnel The customer can t replace by oneself 6 If the power wires requires to be lengthened it i
7. ment from the manufacturer Compressor determined by Turbo Air to have been defective within this extended period will at Turbo Air s discretion be either repaired or replaced with a compressor or compressor parts of similar design and capacity The four 4 year extended compressor warranty applies only to hermetically sealed parts of the compressor and does not apply to any other parts or components including but not limited to cabinet paint finish temperature control refrigerant metering device driers motor starting equipment fan assembly or and other electrical components etcetera 404A 134a Compressor Warranty The five year compressor warranty detailed above will be void if the following procedure is not carefully adhered to 1 This system contains R404A or R134a refrigerant and polyol ester lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better is highly recommended 3 Micron level vacuums must be achieved to insure low moisture levels in the system 500 microns or lower must be obtained 4 When compressor is grounded suction drier and 620 drier or better must be replaced 5 Compressor must be obtained through Turbo Air unless otherwise specified in writing through Turbo Air s warranty department 404A 134a Compressor Warranty Turbo Air s sole obligation unde
8. o comply with warranty policies will result in voiding claims One Year Parts amp Labor Warranty Turbo Air warrants all new refrigerated components the cabinet and all parts to be free from defects in materials or workmanship under normal and proper use and maintenance service as specified by Turbo Air and upon proper installation and start up in accordance with the instruction packet supplied with each Turbo Air unit Turbo Air s obligation under this warranty is limited to a period of one 1 year from the date of original installation or 15 months after shipment date from Turbo Air whichever occurs first Any part covered under this warranty that are by Turbo Air to have been defective within one 1 year of original installation or fifteen 15 months after shipment date from manufacturer whichever occurs first is limited to the repair or replacement including labor charges of defective parts or assemblies The labor warranty shall include standard straight time labor charges only and reasonable travel time as determined by Turbo Air Additional Four Year Compressor Warranty In addition to the one 1 year warranty stated adove Turbo Air warrants its hermetically sealed compressor to be free from defects in both material and workmanship under normal and proper use and maintenance service for a period of four 4 additional years from the date of original installation but not to exceed five 5 years and three 3 months after ship
9. r this warranty is limited to either repair or replacement of parts subject to the additional limitations below This warranty neither assumes nor authorizes any person to assume obligations other than those expressly covered by this warranty NO CONSEQUENTIAL DAMAGES TURBO AIR IS NOT RESPONSIBLE FOR ECONOMIC LOSS PROFIT LOSS OR SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION LOSSES OR DAMAGES ARISING FROM FOOD OR PRODUCT SPOILAGE REGARDLESS OF WHETHER OR NOT THEY RESULT FROM REFRIGERATION FAILURE WARRANTY IS NOT TRANSFERABLE This warranty is not assignable and applies only in favor of the original purchaser user to whom delivered ANY SUCH ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANNTIES HEREIN AND SHALL VOID ALL WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR LABOR COVERAGE FOR COMPONENT FAILURE OR OTHER THE WARRANTY PACKET PROVIDED WITH THE UNIT ALTERATION NEGLECT ABUSE MISUSE ACCIDENT DAMAGE DURING TRANSIT OR INSTALLATION FIRE FOOD ACTS OF GOD Turbo Air is not responsible for the repair or replacement of any parts that Turbo Air determines have been subjected after the date of manufacture to alteration neglect abuse misuse accident damage during transit or installation fire flood or act of GOD IMPROPER ELECTRICAL CONNECTIONS TURBO AIR IS NOT RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF FAILED OR DAMAGED COMPONENTS RESULTING FROM ELECTRICAL POWER FAILURE THE USE OF EXTENSIO
10. replaced with a compressor or compressor parts of similar design and capacity The four 4 year extended compressor warranty applies only to hermetically and semi hermetically sealed parts of the compressor and does not apply to any other parts or components including but not limited to cabinet paint finish temperature control refrigerant metering device driers motor starting equipment fan assembly any other electrical component etcetera 134A 404A COMPRESSOR WARRANTY The five year compressor warranty detailed above will be voided if the following procedure is not carefully adhered to 1 This system contains R134A refrigerant and polyol ester lubricant The Polyol ester lubricant has rapid moisture absorbing qualities If long exposure to the ambient conditions occur the lubricant must be removed and replaced with new Listed below are the approved lubricants for the Tecumseh compressors 1 ICI Emkarate RL 184 2 Emery 2927 A 3 Mobile Artic 22A Failure to comply with recommended lubricant specification will void the compressor warranty 2 Dryer replacement is very important and must be changed when a system is opened for servicing dryer must be used with XH 9 desiccant 3 Micron level vacuums must be achieved to insure low moisture levels in the system 500 microns or lower must obtained What is NOT covered by this warranty Turbo Air s sole obligation under this warranty is limited to either repair or replacement of par
11. s attachment area can not smaller than 1mm 0 04 inch Otherwise it may cause voltage drop and the compressor can not start normally 7 The freezer should be empty for at least 3 hours before storing the food 8 The food storage should not be overloaded allow air circulation It should provide appropriate space to allow air cieculation 9 The key of the freezer should be put in a place where children can not take it inorder to avoid the danger 10 Medicines such as vaccine drugs blood plasma etc are prohibited to store in the freezer 11 Big pieces of food such as meat should be stored and wrapped separately to prevent the damage of the inside wall 12 Do not put the freezer on uneven ground in order to prevent the caster damaged PART IDENTIFICATION 1 cover 7 Dry filter 2 Inner push door 8 Condenser 3 Basket 9 2 5 Caster 4 Body 10 Controller 5 Compressor room window 6 Compressor 1 Glass door 6 Fan 2 Body 7 Dry filter 3 Basket 8 Condenser 4 Compressor 9 Wheel 5 Compressor room window 10 Controller ELECTRICITY PRINCIPLE DIAGRAM Electric Circuit Diagram THERMOSTAT I COMPRESSOR 1 TSD 35CF TSD 45CF TSD 60CF THERMOSTAT Tl COMPRESSOR MOTOR RUNNING LAMP j 2 TSD 27CF farbo air MANUFACTURING COMPANY ONE YEAR WARRANTY Turbo Air warrants to the original purchaser of every new Turbo Air refrigerated unit the cabinet and all parts
12. thereof to befree from defects in material or workmanship under normal use and service for a period of one 1 year from the date of original installation or 15 months after shipment date from Turbo Air whichever occurs first Any parts covered by this warranty that are examined and determined by Turbo Air to have been defective within one 1 year of original installation or fifteen 15 months after shipment date from manufacturer whichever occurs first shall be repaired or replaced as stated below Turbo Air shall be deemed to have fully complied with its obligation under the foregoing warranties by electing either one of the following procedures at the sole discretion of Turbo Air 1 Furnishing a replacement part freight collect in even exchange for the returned part freight collect 2 Receiving the defective part freight collect repairing it and returning it freight collect ADDITIONAL FOUR YEAR COMPRESSOR WARRANTY In addition to the 1 one year warranty stated above Turbo Air warrants its hermetically and semi hermetically sealed compressor to be free from defects in both material and workmanship under normal use and service for a period of four 4 additional years from the date of original installation but not to exceed five 5 years and three 3 months after shipment from manufacturer Compressors determined by Turbo Air have been defective within this extended time period will at Turbo Air s option be either repaired or
13. ts subject to the additional limitations below This warranty neither assumes nor authorizes any person to assume obligations other than expressly covered by this warranty 1 WARRANTY IS NOT TRANSFERABLE This warranty is not assignable and applies only in favor of the original purchaser user to whom delivered ANY SUCH ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANTIES HEREIN MADE AND SHALL VOID ALL WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE 2 NO CONSEQUENTIAL DAMAGES TURBO AIR IS NOT RESPONSIBLE FOR ECONOMIC LOSS PROFIT LOSS OR SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION LOSSES OR DAMAGES ARISING FROM FOOD OR PRODUCT SPOILAGE CLAIMS WHETHER OR NOT ON ACCOUNT OF REFRIGERATION FAILURE 3 ALTERATION NEGLECT ABUSE MISUSE ACCIDENT DAMAGE DURING TRANSIT OR INSTALLATION FIRE FLOOD ACTS OF GOD TURBO AIR is not responsible for the repair or replacement of any parts that Turbo Air determines have been subjected after the date of manufacture to alteration neglect abuse misuse accident damage during transit or installation fire flood or an Act of God 4 IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLIED OR STATUTORY EXCEPT THE ONE 1 YEAR WARRANTY AND THE ADDITIONAL FOUR 4 YEAR COMPRESSOR WARRANTY AS DESCRIBED ABOVE THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL O